+-- Alarm MIB
+-- *****************************************************************
+
+SL-ALARM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ NOTIFICATION-TYPE FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString,
+ TruthValue, TimeStamp FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP,
+ NOTIFICATION-GROUP FROM SNMPv2-CONF
+ InterfaceIndex FROM IF-MIB
+ PerfCurrentCount, PerfIntervalCount,
+ PerfTotalCount FROM PerfHist-TC-MIB
+ slMain FROM SL-MAIN-MIB;
+
+slAlarmMib MODULE-IDENTITY
+ LAST-UPDATED "0008280000Z"
+ ORGANIZATION "PacketLight Networks Ltd."
+ CONTACT-INFO
+ "Omri_Viner@PacketLight.com"
+ DESCRIPTION
+ "This MIB module describes the ALARMS."
+ ::= { slMain 20 }
+
+SlAlarmType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The Alarms Types."
+ SYNTAX INTEGER {
+-- SONET/SDH alarms
+ losSonetAlarm(1), -- Loss Of Signal (S)
+ lofSonetAlarm(2), -- Loss Of Frame (S)
+ lopSonetAlarm(3), -- Loss Of Pointer (P)
+ aisLineSonetAlarm(4), -- Alarm Indication Signal (L)
+ rfiLineSonetAlarm(5), -- Remote Failure Indication (L)
+ uneqSonetAlarm(6), -- Unequipped (P)
+ timLine(7), -- Trace Indication Mismatch (S)
+ slm(8), -- Signal Label Mismatch (P) - Defect
+ sd(9), -- Signal Degrade (SDH only)
+ sf(10), -- Signal Fail (SDH only)
+ hwfail(11), -- HW Fail
+ aisPathSonetAlarm(12), -- Alarm Indication Signal (P)
+ rfiPathSonetAlarm(13), -- Remote Failure Indication (P)
+ timPath(14), -- Trace Indication Mismatch (P)
+ uplinkTransmitMismatch(15), -- Transceiver mismatch or removed (deprecated)
+ uplinkClockSourceLol(16), -- Clock Source Loss of lock
+ aisVtSonetAlarm(21), -- Alarm Indication Signal (V)
+ lopVtSonetAlarm(22), -- Loss Of Pointer (V)
+ rfiVtSonetAlarm(23), -- Remote Failure Indication (V)
+ timVt(24), -- Trace Indication Mismatch (V)
+ slmVt(25), -- Signal Label Mismatch (V)
+ uneqVtSonetAlarm(26), -- Unequipped (V)
+ lomVt(27), -- Loss of Multiframe (V)
+
+-- GFP/VCG alarms
+ vcgFarLossClientSignal(101),-- Far-end Loss of Client Signal
+ vcgFarLossClientSync(102), -- Far-end Loss of Client Sync
+ vcgLossAlignment(103), -- VCG Loss of Alignment
+ vcgLossMultiframe(104), -- VCG Loss of Multiframe
+ vcgLossSequence(105), -- VCG Loss of Sequence
+ vcgGfpLossSync(106), -- GFP framer Loss of Sync
+ vcgFarGfpLossSync(107), -- Far-end GFP Loss of Sync
+ vcgBadGidMember(108), -- Bad GID of a VCAT member
+
+-- Provisioning alarms
+ provUnequipped(151), -- Unprovisioned service
+ provMismatch(152), -- Mismatch provisioning
+
+-- Ethernet alarms
+ ethConfigTransmitFault(201),-- Optical GbE transceiver transmit fault (deprecated)
+ ethConfigLossOfSignal(202), -- Optical GbE transceiver signal detect failed
+ ethConfigLinkFail(203), -- Mac Layer Link failed
+ ethConfigPcsLossSync(204), -- PCS coding loss of sync
+
+-- FC alarms
+ fcBxPortTransmitFault(301), -- Transceiver transmit fault (deprecated)
+ fcBxPortLossOfSignal(302), -- Transceiver signal detect failed
+ fcBxPortNoLink(303), -- No link established yet.
+ fcBxPortLossOfSync(304), -- Loss of sync
+ fcBxPortTransmitMismatch(306), -- Transceiver mismatch or removed (deprecated)
+ fcBxPortPcsLossSync(307), -- PCS coding loss of sync
+
+ fcipLinkNoLink(311), -- No link established yet.
+ fcipLinkLossOfSync(312), -- Loss of sync
+ fcipSntpFailure(313), -- SNTP failure
+ fcipIpsecFailure(314), -- IPSec failure
+ fcipFarLossOfClient(315), -- The Far-End lost the FC link
+
+-- Escon alarms
+ esconPortTransmitFault(351), -- Transceiver transmit fault (deprecated)
+ esconPortLossOfSignal(352), -- Transceiver signal detect failed
+ esconPortNoLink(353), -- No link established yet.
+ esconPortLossOfSync(354), -- Loss of sync
+
+-- EDFA alarms
+ edfaPumpTemperuture(401), -- Pump temperatur is out-of-bound
+ edfaHwFail(403), -- Pump HW failure
+ edfaRvcSignalDetect(404), -- Loss of input signal
+ edfaRcvPower(406), -- Rx Power is out-of-bound
+ edfaTemprature(407), -- Edfa temperature is out-of-bound
+ edfaEyeSafty(408), -- Eye safety alarm (available only in eye-safety mode)
+ edafGainFlatness(409), -- Gain flatness alarm
+ edfaXmtPower(410), -- Tx Power is out-of-bound
+ edfaGain(411), -- Edfa Gain is out-of-bound
+ edfaEol(412), -- Pump End Of Life
+
+-- Muxponder alarms
+ muxAisPath(451) , -- Muxponder AIS
+ muxLof(452), -- Muxponder LOF
+ muxRdi(453), -- Muxponder RDI
+ muxInbandFail(454), -- Muxponder Inband Fail
+ muxTempLicense(455), -- Muxponder Temporary Licensed
+ muxNoLicense(456), -- Muxponder Not Licensed
+
+-- Optical Switch alarms
+ oswHwFail(470), -- The optical switch is defined in seep but not exist
+ oswLossOfSignal(471), -- LOS is detected on the port of the optical switch
+ oswEdfaLossProp(472),
+
+-- Port alarms
+ loopback(501), -- The port is in loopback
+ apsForceActive(502), -- Force Switch is active on this port
+ apsManualActive(503), -- Manual Switch is active on this port
+
+-- CLU alarms
+ cluHoldoverState(602), -- Clu is switched to holdover
+ cluFreerunState(603), -- Clu is in free run state
+ cluBelowLevel(604), -- Clock is below internal level
+ cluFail(606), -- Clock fail
+ cluJittered(608), -- Clock jittered
+
+-- WSS alarms
+ channelLowDegrade(621), -- OCM Power Level Parameter 2
+ channelHighDegrade(622), -- OCM Power Level Parameter 3
+ channelLowFail(623), -- OCM Power Level Parameter 4
+ channelHighFail(624), -- OCM Power Level Parameter 5
+ unequalizedOuputPower(625), -- Failed to equalize channels output power
+
+-- SFP Alarms
+ sfpTransmitFault(701), -- sfp hardware problem
+ sfpRemoved(702), -- spf is either removed or failed
+ sfpMuxWlMismatch(703), -- wl of the sfp does not match the wls of the mux
+ sfpBitRateMismatch(704), -- the sfp bit rate does not match the implied port rate
+ sfpLossOfLock(705), -- retimer problem
+ sfpSfpWlMismatch(706), -- two sfps with the same wave length in
+ sfpLossOfLight(707), -- no signnal detection
+ sfpLaserEndOfLife(708), -- laser end of life indication
+ sfpMuxSpacingMismatch(709), -- spacing of the sfp does not match the spacing of the mux
+ sfpHardwareFault(710), -- wrong sfp crc
+ sfpBlocked(711), -- the sfp is blocked
+ sfpLossPropagation(712), -- shut laser due to a problem with the mate sfp
+ sfpUnknownType(713), -- unknown sfp type warning - doesn't shut the laser
+
+ sfpHighTemp(720), -- internal temperature exceeds high alarm level.
+ sfpLowTemp(721), -- internal temperature is below low alarm level.
+ sfpHighTxPower(726), -- TX output power exceeds high alarm level.
+ sfpLowTxPower(727), -- TX output power is below low alarm level.
+ sfpHighRxPower(728), -- Received Power exceeds high alarm level.
+ sfpLowRxPower(729), -- Received Power is below low alarm level.
+ sfpHighLaserTemp(730), -- (15xy) laser TEC current exceeds high alarm level.
+ sfpLowLaserTemp(731), -- (15xy) laser TEC current exceeds low alarm level.
+ sfpHighLaserWl(732), -- (15xy) laser wavelength exceeds high alarm level.
+ sfpLowLaserWl(733), -- (15xy) laser wavelength is below low alarm level.
+
+-- XFP Alarms
+ xfpTxNR(734),
+ xfpTxCdrNotLocked(735),
+ xfpRxNR(736),
+ xfpRxCdrNotLocked(737),
+
+-- OTN Alarms
+ otnFecExc(750), -- FEC-EXC Trail Excessive Errors (Early FEC) > 10-4
+ otnFecDeg(751), -- FEC-DEG Trail Degraded Errors (Early FEC) > 10-8
+ otnOtuDeg(752), -- S-DEG Section- Degraded Performance. Based on SM BIP
+ otnOduDeg(753), -- P-DEG Path- Degraded Performance. Based on PM BIP
+ otnLos(754), -- LOS Loss of Signal
+ otnLof(755), -- LOF Loss of Frame. OOF present for at least 3ms
+ otnLom(756), -- LOM Loss of Multiframe; OOM present for at least 3ms
+ otuAis(757), -- S-AIS Section-Alarm Indication Signal
+ otuBdi(758), -- S-BDI Section-Backward Defect Indicator
+ otuTtim(759), -- S-TTIM Section-Trail Trace Identifier Mismatch (SAPI/DAPI)
+ oduAis(780), -- P-AIS Path-Alarm Indication Signal
+ oduOci(781), -- P-OCI Path-Open Connection indicator
+ oduLck(782), -- P-LCK Path-Locked. Path Locked active
+ oduBdi(783), -- P-BDI Path-Backward Error indicator.
+ oduTtim(784), -- P-TTIM Path-Trail Trace Identifier Mismatch (SAPI/DAPI)
+ oduPtm(785), -- P-PTM Path Payload Type Mismatch
+
+-- NE alarms
+ entityRemoved(801), -- Card is removed from the slot
+ entityClockFail(803), -- Clock Failure
+ entityHwTxFail(804), -- HW or Tx failure
+ entitySwMismatch(806), -- SW version mismatch detected
+ entitySwUpgrade(807), -- Software Upgrade in progress
+ entitySwInvalidBank(808), -- Software Bank is invalid
+ entityIpLanPending(820), -- new LAN IP address is pending
+ entityIpOscPending(821), -- new OSC IP address is pending
+ nePowerFault(902), -- Power supply unit has failed
+ neFanFault(903), -- Fan unit has failed
+ neLowVoltagePower(904), -- The voltage of the Power Supply is too low
+ entitySwUpgradeFail(905), -- SW Upgrade Failed
+ entityRadiusPrimFail(906), -- Radius Primary Server failed
+ entityRadiusSecFail(907), -- Radius Secondary Server failed
+ entityDbRestoreFail(908), -- Database Restore Failed
+ entityDbRestoreInProgress(909), -- Database Restore In Progress
+ entitySntpFail(910), -- SNTP server failure
+
+-- Misc
+ dcActive(1001), -- An alarm on the input dry contact
+ lcpDown(1002), -- The LCP link is down
+ ncpDown(1003), -- The NCP link is down
+ rtcFailure(1004) -- RTC failure
+ }
+
+
+slAlarmConfig OBJECT IDENTIFIER ::= { slAlarmMib 1 }
+slAlarmTraps OBJECT IDENTIFIER ::= { slAlarmMib 2 }
+slAlarmTraps0 OBJECT IDENTIFIER ::= { slAlarmTraps 0 }
+
+--
+-- SL Alarms config Table
+--
+
+slAlarmConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SlAlarmConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects to configure the SL Alarms."
+ ::= { slAlarmConfig 1 }
+
+slAlarmConfigEntry OBJECT-TYPE
+ SYNTAX SlAlarmConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry exist for each type of alarm.
+ The entry describes the alarm properties."
+ INDEX { slAlarmIfIndex, slAlarmType }
+ ::= { slAlarmConfigTable 1 }
+
+SlAlarmConfigEntry ::=
+ SEQUENCE {
+ slAlarmIfIndex InterfaceIndex,
+ slAlarmType SlAlarmType,
+ slAlarmSeverity INTEGER,
+ slAlarmServiceAffect TruthValue,
+ slAlarmTimeStamp TimeStamp,
+ slAlarmAcknowledged TruthValue,
+ slAlarmAckUser DisplayString,
+ slAlarmText DisplayString
+ }
+
+slAlarmIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The corresponding interface index.
+ The interface type may be one of:
+ - Sonet Line,
+ - Sonet Path,
+ - CLU
+ - NE."
+ ::= { slAlarmConfigEntry 1 }
+
+slAlarmType OBJECT-TYPE
+ SYNTAX SlAlarmType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm type."
+ ::= { slAlarmConfigEntry 2 }
+
+slAlarmSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm(0),
+ critical(1),
+ major(2),
+ minor(3),
+ cleared(4),
+ notification(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm severity."
+ ::= { slAlarmConfigEntry 3 }
+
+slAlarmServiceAffect OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm service affecting Yes/No."
+ ::= { slAlarmConfigEntry 4 }
+
+slAlarmTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The calendar time of the alarm."
+ ::= { slAlarmConfigEntry 5 }
+
+slAlarmAcknowledged OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allow the NMS to acknowledge an active alarm."
+ ::= { slAlarmConfigEntry 6 }
+
+slAlarmAckUser OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the user that performed the Ack."
+ ::= { slAlarmConfigEntry 7 }
+
+slAlarmText OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm text."
+ ::= { slAlarmConfigEntry 8 }
+
+
+--
+-- SL ALARM TRAPS
+--
+
+slAlarmActive OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm is active Yes/No."
+ ::= { slAlarmTraps 1 }
+
+slAlarmTrap NOTIFICATION-TYPE
+ OBJECTS {slAlarmIfIndex,
+ slAlarmType,
+ slAlarmSeverity,
+ slAlarmServiceAffect,
+ slAlarmActive,
+ slAlarmText
+ }
+ STATUS current
+ DESCRIPTION
+ "An slAlarmTrap notification is sent when an alarm occures."
+ ::= { slAlarmTraps 2 }
+
+
+slAlarmTrap0 NOTIFICATION-TYPE
+ OBJECTS {slAlarmIfIndex,
+ slAlarmType,
+ slAlarmSeverity,
+ slAlarmServiceAffect,
+ slAlarmActive,
+ slAlarmText
+ }
+ STATUS current
+ DESCRIPTION
+ "An slAlarmTrap0 notification is sent when an alarm occures.
+ It is defined to support browsers that don't recognize RFC 2576."
+ ::= { slAlarmTraps0 2 }
+
+
+END
+
+
+