diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/opengear/OGTRAP-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/opengear/OGTRAP-MIB')
| -rw-r--r-- | MIBS/opengear/OGTRAP-MIB | 401 |
1 files changed, 401 insertions, 0 deletions
diff --git a/MIBS/opengear/OGTRAP-MIB b/MIBS/opengear/OGTRAP-MIB new file mode 100644 index 0000000..ff926ae --- /dev/null +++ b/MIBS/opengear/OGTRAP-MIB @@ -0,0 +1,401 @@ +OGTRAP-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215 + enterprises FROM + RFC1155-SMI; + + opengear OBJECT IDENTIFIER ::= { enterprises 25049 } + + ogLegacyMgmt OBJECT IDENTIFIER ::= { opengear 2 } + + ogConnectMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 10 } + ogSignalMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 11 } + ogPatternMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 12 } + ogSensorMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 13 } + ogHostMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 14 } + ogFailoverMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 15 } + ogNetUpsMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 16 } + ogDataMib OBJECT IDENTIFIER ::= { ogLegacyMgmt 17 } + + -- Serial port connection traps. + ogConnectMibObjects OBJECT IDENTIFIER ::= { ogConnectMib 10 } + ogconnEvent OBJECT IDENTIFIER ::= { ogConnectMibObjects 1 } + ogconnEventTable OBJECT IDENTIFIER ::= { ogconnEvent 1 } + ogconnEventEntry OBJECT IDENTIFIER ::= { ogconnEventTable 1 } + + ogconnEventUsername OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user pertaining to the connection event" + ::= { ogconnEventEntry 10 } + + ogconnEventType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of connection event" + ::= { ogconnEventEntry 11 } + + ogconnEventPortNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Serial port number on which this connection applies" + ::= { ogconnEventEntry 12 } + + ogconnEventPortLabel OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The label for the serial port where the connection + occurred." + ::= { ogconnEventEntry 13 } + + ogconnEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ogconnEventUsername, + ogconnEventType, + ogconnEventPortNumber, + ogconnEventPortLabel + } + DESCRIPTION + "The alert sent when a user connection event occurs." + ::= 1001 + + -- Serial port signal trap + ogSignalMibObjects OBJECT IDENTIFIER ::= { ogSignalMib 10 } + ogsgnlEvent OBJECT IDENTIFIER ::= { ogSignalMibObjects 1 } + ogsgnlEventTable OBJECT IDENTIFIER ::= { ogsgnlEvent 1 } + ogsgnlEventEntry OBJECT IDENTIFIER ::= { ogsgnlEventTable 1 } + + ogsgnlEventType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The particular signal which changed" + ::= { ogsgnlEventEntry 10 } + + ogsgnlEventState OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current signal state" + ::= { ogsgnlEventEntry 11 } + + ogsgnlEventPortNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Serial port number on which this signal applies" + ::= { ogsgnlEventEntry 12 } + + ogsgnlEventPortLabel OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The label for the serial port where the signal applies." + ::= { ogsgnlEventEntry 13 } + + ogsgnlEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ogsgnlEventType, + ogsgnlEventState, + ogsgnlEventPortNumber, + ogsgnlEventPortLabel } + DESCRIPTION + "The alert sent when a signal change occurs" + ::= 1002 + + -- Serial console pattern traps + ogPatternMibObjects OBJECT IDENTIFIER ::= { ogPatternMib 10 } + ogpatnEvent OBJECT IDENTIFIER ::= { ogPatternMibObjects 1 } + ogpatnEventTable OBJECT IDENTIFIER ::= { ogpatnEvent 1 } + ogpatnEventEntry OBJECT IDENTIFIER ::= { ogpatnEventTable 1 } + + ogpatnEventDescription OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A description of the matches purpose" + ::= { ogpatnEventEntry 10 } + + ogpatnEventText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The full text which matched the pattern" + ::= { ogpatnEventEntry 11 } + + ogpatnEventPortNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Serial port number on which the pattern matched" + ::= { ogpatnEventEntry 12 } + + ogpatnEventPortLabel OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The label for the serial port where pattern match + occurred" + ::= { ogpatnEventEntry 13 } + + ogpatnEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ogpatnEventDescription, + ogpatnEventText, + ogpatnEventPortNumber, + ogpatnEventPortLabel } + DESCRIPTION + "The alert sent when a pre-defined pattern was + matched text in a consoles serial character stream" + ::= 1003 + + -- Sensor traps + ogSensorMibObjects OBJECT IDENTIFIER ::= { ogSensorMib 10 } + ogsensStatus OBJECT IDENTIFIER ::= { ogSensorMibObjects 1 } + ogsensStatusTable OBJECT IDENTIFIER ::= { ogsensStatus 1 } + ogsensStatusEntry OBJECT IDENTIFIER ::= { ogsensStatusTable 1 } + + ogsensStatusName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the device pertaining to the status event" + ::= { ogsensStatusEntry 10 } + + ogsensStatusDevType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of device pertaining to the status event" + ::= { ogsensStatusEntry 11 } + + ogsensStatusType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of sensor pertaining to the status event" + ::= { ogsensStatusEntry 12 } + + ogsensStatusValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of the sensor pertaining to the status event" + ::= { ogsensStatusEntry 13 } + + ogsensStatusOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ogsensStatusName, + ogsensStatusDevType, + ogsensStatusType, + ogsensStatusValue } + DESCRIPTION + "The trap sent when a sensor event occurs" + ::= 1004 + + -- Host traps + ogHostMibObjects OBJECT IDENTIFIER ::= { ogHostMib 10 } + oghostEvent OBJECT IDENTIFIER ::= { ogHostMibObjects 1 } + oghostEventTable OBJECT IDENTIFIER ::= { oghostEvent 1 } + oghostEventEntry OBJECT IDENTIFIER ::= { oghostEventTable 1 } + + oghostEventUsername OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The user pertaining to the connection event" + ::= { oghostEventEntry 10 } + + oghostEventType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of connection event" + ::= { oghostEventEntry 11 } + + oghostEventAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The address of the host to which this connection applies." + ::= { oghostEventEntry 12 } + + oghostEventDescription OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The description of the host to which this connection applies." + ::= { oghostEventEntry 13 } + + oghostEventProtocol OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The internet protocl to which this connection applies." + ::= { oghostEventEntry 14 } + + oghostEventPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The applicable port number of the host." + ::= { oghostEventEntry 15 } + + oghostEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + oghostEventUsername, + oghostEventType, + oghostEventAddress, + oghostEventDescription, + oghostEventProtocol, + oghostEventPort } + DESCRIPTION + "The alert sent when a user connection event occurs" + ::= 2001 + + -- Failover traps + ogFailoverMibObjects OBJECT IDENTIFIER ::= { ogFailoverMib 10 } + ogfovrEvent OBJECT IDENTIFIER ::= { ogFailoverMibObjects 1 } + ogfovrEventTable OBJECT IDENTIFIER ::= { ogfovrEvent 1 } + ogfovrEventEntry OBJECT IDENTIFIER ::= { ogfovrEventTable 1 } + + ogfovrEventPrimary OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the network interface which failed" + ::= { ogfovrEventEntry 10 } + + ogfovrEventSecondary OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the network interface which was connected + instead" + ::= { ogfovrEventEntry 11 } + + ogfovrEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { ogfovrEventPrimary, ogfovrEventSecondary } + DESCRIPTION + "The alert sent when a network failover event occurs" + ::= 2002 + + -- Ups trap + ogNetUpsMibObjects OBJECT IDENTIFIER ::= { ogNetUpsMib 10 } + ognupsEvent OBJECT IDENTIFIER ::= { ogNetUpsMibObjects 1 } + ognupsEventTable OBJECT IDENTIFIER ::= { ognupsEvent 1 } + ognupsEventEntry OBJECT IDENTIFIER ::= { ognupsEventTable 1 } + + ognupsEventName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the UPS pertaining to the status event" + ::= { ognupsEventEntry 10 } + + ognupsEventType OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of status event" + ::= { ognupsEventEntry 11 } + + ognupsEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ognupsEventName, + ognupsEventType } + DESCRIPTION + "The alert sent when a UPS status event occurs" + ::= 2003 + + -- Data Usage trap + ogDataMibObjects OBJECT IDENTIFIER ::= { ogDataMib 10 } + ogdataEvent OBJECT IDENTIFIER ::= { ogDataMibObjects 1 } + ogdataEventTable OBJECT IDENTIFIER ::= { ogdataEvent 1 } + ogdataEventEntry OBJECT IDENTIFIER ::= { ogdataEventTable 1 } + + ogdataEventBytes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of bytes which triggers this usage alert" + ::= { ogdataEventEntry 10 } + + ogdataEventSeconds OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The time in seconds over which bytes are measured" + ::= { ogdataEventEntry 11 } + + ogdataEventDevice OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ID for the interface thos pertains to" + ::= { ogdataEventEntry 12 } + + ogdataEventState OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Whether data usage alert is on (1) or off (0)" + ::= { ogdataEventEntry 13 } + + ogdataEventOccurred TRAP-TYPE + ENTERPRISE opengear + VARIABLES { + ogdataEventBytes, + ogdataEventSeconds, + ogdataEventDevice, + ogdataEventState } + DESCRIPTION + "The trap sent when a data usage alert occurs" + ::= 2004 + +END |