Diffstat (limited to 'MIBS/oneaccess/ONEACCESS-SYS-MIB')
-rw-r--r--MIBS/oneaccess/ONEACCESS-SYS-MIB483
1 files changed, 483 insertions, 0 deletions
diff --git a/MIBS/oneaccess/ONEACCESS-SYS-MIB b/MIBS/oneaccess/ONEACCESS-SYS-MIB
new file mode 100644
index 0000000..da08612
--- /dev/null
+++ b/MIBS/oneaccess/ONEACCESS-SYS-MIB
@@ -0,0 +1,483 @@
+-- *****************************
+-- * *
+-- * ONEOS MIB *
+-- * *
+-- *****************************
+--
+-- ONEOS_MIB_STD_V05.1.R005_E001
+--
+-- Creation date : 18/02/2003
+--
+-- Compatibility with ONEOS_V31
+--
+-- Compatibility with ONEOS_V32
+--
+-- Compatibility with ONEOS_V33
+--
+-- Compatibility with ONEOS_V34
+--
+-- Modified for ONEOS_V32R2E26 : oacSysIMSysMainBoard added
+--
+-- 10032005 : Add hardware description
+--
+-- 20060111 : Add oacSysSecureCrashlogCount
+--
+-- 20100412 : Add oacSysStartCaused
+--
+-- 20100811 : Add objects for Factory area description
+--
+-- 20120824 : Add object Product Name
+--
+ ONEACCESS-SYS-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,Unsigned32
+ FROM SNMPv2-SMI
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ TEXTUAL-CONVENTION, DisplayString
+ FROM SNMPv2-TC
+ oacExpIMSystem,oacMIBModules
+ FROM ONEACCESS-GLOBAL-REG;
+
+ oacSysMIBModule MODULE-IDENTITY
+ LAST-UPDATED "201405050001Z"
+ ORGANIZATION " OneAccess "
+ CONTACT-INFO
+ "Pascal KESTELOOT
+ Postal: ONE ACCESS
+ 381 Avenue du General de Gaulle
+ 92140 Clamart, France
+ FRANCE
+
+ Tel: (+33) 01 41 87 70 00
+ Fax: (+33) 01 41 87 74 00
+
+ E-mail: pascal.kesteloot@oneaccess-net.com"
+
+ DESCRIPTION
+ "Add Cpu usage table for multicore HW"
+
+ REVISION "201405050001Z"
+
+ DESCRIPTION
+ "Contact updated"
+ REVISION "201106150000Z"
+
+ DESCRIPTION
+ "oacExpIMSysFactory OID updated"
+ REVISION "201012140001Z"
+
+ DESCRIPTION "Add objects for Factory area description."
+ REVISION "201008111000Z" -- August 11, 2010
+
+ DESCRIPTION
+ "Fixed minor corrections. changed oacExpIMSysHwcDescription
+ type from OCTET STRING to DisplayString."
+ REVISION "201007081000Z"
+
+ DESCRIPTION
+ "This MIB module describes system Management objects."
+
+ ::= { oacMIBModules 671 }
+
+
+-- ----------------------------------------------------------------------------
+-- >> textual conventions
+-- ----------------------------------------------------------------------------
+
+OASysHwcClass ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The object specify the class of OASysHwc"
+ SYNTAX INTEGER
+ {
+ board(0),
+ cpu(1),
+ slot(2)
+ }
+
+OASysHwcType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The object specify the type of OASysHwc"
+ SYNTAX INTEGER
+ {
+ mainboard(0),
+ microprocessor(1),
+ ram(2),
+ flash(3),
+ dsp(4),
+ uplink(5),
+ module(6)
+ }
+
+OASysCoreType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The object specify the type of Core usage"
+ SYNTAX INTEGER
+ {
+ controlplane(0),
+ dataforwarding(1),
+ application(2),
+ mixed(3)
+ }
+
+
+oacExpIMSysStatistics OBJECT IDENTIFIER ::= { oacExpIMSystem 1 }
+oacExpIMSysHardwareDescription OBJECT IDENTIFIER ::= { oacExpIMSystem 2 }
+
+oacSysMemStatistics OBJECT IDENTIFIER ::= { oacExpIMSysStatistics 1 }
+oacSysCpuStatistics OBJECT IDENTIFIER ::= { oacExpIMSysStatistics 2 }
+
+oacSysSecureCrashlogCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of avaiable crash logs"
+ ::= { oacExpIMSysStatistics 100 }
+
+oacSysStartCaused OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cause of system start"
+ ::= { oacExpIMSysStatistics 200 }
+
+oacSysIMSysMainBoard OBJECT IDENTIFIER ::= { oacExpIMSysHardwareDescription 1 }
+
+oacExpIMSysHwComponents OBJECT IDENTIFIER ::= { oacExpIMSysHardwareDescription 2 }
+
+oacExpIMSysFactory OBJECT IDENTIFIER ::= { oacExpIMSysHardwareDescription 3 }
+
+
+oacSysIMSysMainIdentifier OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor's authoritative identification of
+ the main board. This value is allocated within
+ the SMI enterprise subtree"
+ ::= { oacSysIMSysMainBoard 1 }
+
+oacSysIMSysMainManufacturedIdentity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique ID string self to each equipment.
+ By default, it is retrieved from the
+ manufacturer of the equipment. Can also be
+ configure by CLI ( see command 'snmp chassis-id')
+ for customer purposes"
+ ::= { oacSysIMSysMainBoard 2 }
+
+oacSysIMSysMainManufacturedDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the date of the manufacturing of
+ the equipment"
+ ::= { oacSysIMSysMainBoard 3 }
+
+oacSysIMSysMainCPU OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of the main CPU used
+ on the main board"
+ ::= { oacSysIMSysMainBoard 4 }
+
+oacSysIMSysMainBSPVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current BSP version supported
+ on the equipment"
+ ::= { oacSysIMSysMainBoard 5 }
+
+oacSysIMSysMainBootVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current boot version supported
+ on the equipment"
+ ::= { oacSysIMSysMainBoard 6 }
+
+oacSysIMSysMainBootDateCreation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the date the current boot version
+ has been generated"
+ ::= { oacSysIMSysMainBoard 7 }
+
+
+
+
+oacSysMemoryFree OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes in free memory "
+ ::= { oacSysMemStatistics 1 }
+
+oacSysMemoryAllocated OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes in allocated memory "
+ ::= { oacSysMemStatistics 2 }
+
+oacSysMemoryTotal OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of bytes in the system memory partition "
+ ::= { oacSysMemStatistics 3 }
+
+oacSysMemoryUsed OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used memory expressed in percent of the total memory size "
+ ::= { oacSysMemStatistics 4 }
+
+oacSysCpuUsed OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used cpu in percent "
+ ::= { oacSysCpuStatistics 1 }
+
+------------------------------------------------------------------------------
+-->> Cpu usage table for multicore HW
+------------------------------------------------------------------------------
+oacSysCpuUsedCoresCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Cores for the equipment"
+ ::= { oacSysCpuStatistics 2 }
+
+oacSysCpuUsedCoresTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OacSysCpuUsedCoresEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table for Oneaccess hardware Cores"
+ ::= { oacSysCpuStatistics 3 }
+
+oacSysCpuUsedCoresEntry OBJECT-TYPE
+ SYNTAX OacSysCpuUsedCoresEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for a hardware Core"
+ INDEX { oacSysCpuUsedIndex }
+ ::= { oacSysCpuUsedCoresTable 1 }
+
+OacSysCpuUsedCoresEntry ::=
+ SEQUENCE {
+ oacSysCpuUsedIndex Unsigned32,
+ oacSysCpuUsedCoreType OASysCoreType,
+ oacSysCpuUsedValue Unsigned32,
+ oacSysCpuUsedOneMinuteValue Unsigned32
+ }
+
+oacSysCpuUsedIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Core index"
+ ::= { oacSysCpuUsedCoresEntry 1 }
+
+oacSysCpuUsedCoreType OBJECT-TYPE
+ SYNTAX OASysCoreType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of the core"
+ ::= { oacSysCpuUsedCoresEntry 2 }
+
+ oacSysCpuUsedValue OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used cpu in percent : equivalent for core 0 to the oacSysCpuUsed object. This is the current value"
+ ::= { oacSysCpuUsedCoresEntry 3 }
+
+ oacSysCpuUsedOneMinuteValue OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cpu load for the last minute period"
+ ::= { oacSysCpuUsedCoresEntry 4 }
+
+
+oacSysLastRebootCause OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "To display the cause for the last reboot."
+ ::= { oacExpIMSysStatistics 3 }
+
+-- ----------------------------------------------------------------------------
+-- >> hardware components
+-- ----------------------------------------------------------------------------
+oacExpIMSysHwComponentsCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of components for the equipment"
+ ::= { oacExpIMSysHwComponents 1 }
+
+oacExpIMSysHwComponentsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OacExpIMSysHwComponentsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table for Oneaccess hardware components"
+ ::= { oacExpIMSysHwComponents 2 }
+
+oacExpIMSysHwComponentsEntry OBJECT-TYPE
+ SYNTAX OacExpIMSysHwComponentsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table entry for a hardware component"
+ INDEX { oacExpIMSysHwcIndex }
+ ::= { oacExpIMSysHwComponentsTable 1 }
+
+OacExpIMSysHwComponentsEntry ::=
+ SEQUENCE {
+ oacExpIMSysHwcIndex Unsigned32,
+ oacExpIMSysHwcClass OASysHwcClass,
+ oacExpIMSysHwcType OASysHwcType,
+ oacExpIMSysHwcDescription DisplayString,
+ oacExpIMSysHwcSerialNumber DisplayString,
+ oacExpIMSysHwcManufacturer DisplayString,
+ oacExpIMSysHwcManufacturedDate DisplayString,
+ oacExpIMSysHwcProductName DisplayString
+ }
+
+oacExpIMSysHwcIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Component index"
+ ::= { oacExpIMSysHwComponentsEntry 1 }
+
+oacExpIMSysHwcClass OBJECT-TYPE
+ SYNTAX OASysHwcClass
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Class of the component"
+ ::= { oacExpIMSysHwComponentsEntry 2 }
+
+oacExpIMSysHwcType OBJECT-TYPE
+ SYNTAX OASysHwcType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of the component"
+ ::= { oacExpIMSysHwComponentsEntry 3 }
+
+oacExpIMSysHwcDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Component description, identifies the component"
+ ::= { oacExpIMSysHwComponentsEntry 4 }
+
+oacExpIMSysHwcSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Component's serial number"
+ ::= { oacExpIMSysHwComponentsEntry 5 }
+
+oacExpIMSysHwcManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Component manufacturer"
+ ::= { oacExpIMSysHwComponentsEntry 6 }
+
+oacExpIMSysHwcManufacturedDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Component's manufacturing date"
+ ::= { oacExpIMSysHwComponentsEntry 7 }
+
+oacExpIMSysHwcProductName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Product name"
+ ::= { oacExpIMSysHwComponentsEntry 8 }
+
+-- ----------------------------------------------------------------------------
+-- Factory area
+-- ----------------------------------------------------------------------------
+
+oacExpIMSysFactorySupplierID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..14))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Supplier ID. Mapped to Mid field of product-info-area.
+ String is empty if Mid field is not included in
+ product-info-area."
+ ::= { oacExpIMSysFactory 1 }
+
+oacExpIMSysFactoryProductSalesCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..22))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OA Product Sales Code. Mapped to Mcode field of
+ product-info-area. String is empty if Mcode field
+ is not included in product-info-area."
+ ::= { oacExpIMSysFactory 2 }
+
+oacExpIMSysFactoryHwRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (2..7))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware Revision. Mapped to Mrevision field of
+ product-info-area. String is empty if Mrevision
+ field is not included in product-info-area."
+ ::= { oacExpIMSysFactory 3 }
+
+END
+--