summaryrefslogtreecommitdiff
path: root/MIBS/mrv/NBS-EFM-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/mrv/NBS-EFM-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/mrv/NBS-EFM-MIB')
-rw-r--r--MIBS/mrv/NBS-EFM-MIB1143
1 files changed, 1143 insertions, 0 deletions
diff --git a/MIBS/mrv/NBS-EFM-MIB b/MIBS/mrv/NBS-EFM-MIB
new file mode 100644
index 0000000..82451e7
--- /dev/null
+++ b/MIBS/mrv/NBS-EFM-MIB
@@ -0,0 +1,1143 @@
+
+NBS-EFM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+
+ Counter32, Counter64,
+ OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI
+
+ OBJECT-GROUP
+ FROM SNMPv2-CONF
+
+ InterfaceIndex
+ FROM IF-MIB
+
+ nbs, Unsigned16TC
+ FROM NBS-MIB
+
+ ;
+
+
+nbsEfmMib MODULE-IDENTITY
+ LAST-UPDATED "201610190000Z" -- October 19, 2016
+ ORGANIZATION "NBS"
+ CONTACT-INFO
+ "For technical support, please contact your service channel"
+ DESCRIPTION
+ "Private MRV MIB for representing 802.3ah (Ethernet in the
+ First Mile) information"
+
+ ::= { nbs 300 }
+
+
+-- *******************************************************************
+-- NBS-EFM-MIB Objects Identifier Definition
+-- *******************************************************************
+
+nbsEfmProduct OBJECT IDENTIFIER ::= { nbsEfmMib 2 }
+nbsEfmNc316Nm OBJECT IDENTIFIER ::= { nbsEfmProduct 1 }
+
+nbsEfmObjects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "all MIB objects in nbsEfm MIB."
+::= { nbsEfmMib 1 }
+
+-- *******************************************************************
+-- Groups in NBS-EFM-MIB - all under nbsEfmObjects
+-- *******************************************************************
+
+
+-- nbsEfmDteMacGrp OBJECT-IDENTITY
+-- STATUS current
+-- DESCRIPTION
+-- "All DTE MAC Objects."
+-- ::= { nbsEfmObjects 1 }
+
+-- nbsEfmMauGrp OBJECT-IDENTITY
+-- STATUS current
+-- DESCRIPTION
+-- "All MAU objects."
+-- ::= { nbsEfmObjects 2 }
+
+nbsEfmOamGrp OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "All OAM objects."
+::= { nbsEfmObjects 3 }
+
+-- nbsEfmOmpGrp OBJECT-IDENTITY
+-- STATUS current
+-- DESCRIPTION
+-- "All OMP objects."
+-- ::= { nbsEfmObjects 4 }
+
+-- nbsOsTraps OBJECT-IDENTITY
+-- STATUS current
+-- DESCRIPTION
+-- "All Defined Specific Traps."
+-- ::= { nbsOsMIBObjects 5 }
+
+
+
+-- *******************************************************************
+-- Objects in the OAM Group.
+-- *******************************************************************
+
+
+
+nbsEfmOamTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NbsEfmOamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Operations, Administration, and Management information"
+ ::= { nbsEfmOamGrp 1 }
+
+nbsEfmOamEntry OBJECT-TYPE
+ SYNTAX NbsEfmOamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains a desription of a particular Oam. There are two
+ entries for each OAM link, one entry for the local side,
+ one for the remote."
+ INDEX { nbsEfmPhysicalIfIndex }
+ ::= { nbsEfmOamTable 1 }
+
+
+NbsEfmOamEntry ::= SEQUENCE {
+ nbsEfmPhysicalIfIndex InterfaceIndex,
+ nbsEfmOamIfIndex InterfaceIndex,
+ nbsEfmOamPeerIfIndex InterfaceIndex,
+ nbsEfmOamMode INTEGER,
+ nbsEfmOamCfg OCTET STRING,
+ nbsEfmOamPduCfg Unsigned16TC,
+ nbsEfmOamFlagsField OCTET STRING,
+ nbsEfmOamState OCTET STRING,
+ nbsEfmOamVendorOUI OCTET STRING,
+ nbsEfmOamVendorDeviceId Unsigned16TC,
+ nbsEfmOamVendorDeviceVersion Unsigned16TC,
+ nbsEfmOamPDUTx Counter32,
+ nbsEfmOamPDURx Counter32,
+ nbsEfmOamUnsupportedCodesRx Counter32,
+ nbsEfmOamInformationTx Counter32,
+ nbsEfmOamInformationRx Counter32,
+ nbsEfmOamEventNotificationTx Counter32,
+ nbsEfmOamUniEventNotificationRx Counter32,
+ nbsEfmOamDupEventNotificationRx Counter32,
+ nbsEfmOamLoopbackControlTx Counter32,
+ nbsEfmOamLoopbackControlRx Counter32,
+ nbsEfmOamVariableRequestTx Counter32,
+ nbsEfmOamVariableRequestRx Counter32,
+ nbsEfmOamVariableResponseTx Counter32,
+ nbsEfmOamVariableResponseRx Counter32,
+ nbsEfmOamOrganizationSpecificTx Counter32,
+ nbsEfmOamOrganizationSpecificRx Counter32,
+ nbsEfmOamErrSymPerCfgDuration Counter64,
+ nbsEfmOamErrSymPerCfgThreshld Counter32,
+ nbsEfmOamErrSymPerEvtTime Unsigned16TC,
+ nbsEfmOamErrSymPerEvtWindow Counter64,
+ nbsEfmOamErrSymPerEvtThreshld Counter64,
+ nbsEfmOamErrSymPerEvtCount Counter64,
+ nbsEfmOamErrFrmCfgDuration Counter32,
+ nbsEfmOamErrFrmCfgThreshld Counter32,
+ nbsEfmOamErrFrmEvtTime Unsigned16TC,
+ nbsEfmOamErrFrmEvtWindow Unsigned16TC,
+ nbsEfmOamErrFrmEvtThreshld Counter32,
+ nbsEfmOamErrFrmEvtCount Counter64,
+ nbsEfmOamErrFrmPerCfgDuration Counter32,
+ nbsEfmOamErrFrmPerCfgThreshld Counter32,
+ nbsEfmOamErrFrmPerEvtTime Unsigned16TC,
+ nbsEfmOamErrFrmPerEvtWindow Counter32,
+ nbsEfmOamErrFrmPerEvtThreshld Counter32,
+ nbsEfmOamErrFrmPerEvtCount Counter64,
+ nbsEfmOamErrFrmSecSumCfgDuration Unsigned16TC,
+ nbsEfmOamErrFrmSecSumCfgThreshld Unsigned16TC,
+ nbsEfmOamErrFrmSecSumEvtTime Unsigned16TC,
+ nbsEfmOamErrFrmSecSumEvtWindow Unsigned16TC,
+ nbsEfmOamErrFrmSecSumEvtThreshld Unsigned16TC,
+ nbsEfmOamErrFrmSecSumEvtCount Counter32,
+ nbsEfmOamFramesLostDueToOamError Counter32,
+ nbsEfmOamAdminState INTEGER,
+ nbsEfmOamOperState OCTET STRING
+}
+
+nbsEfmPhysicalIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ifIndex from the MIB-II Interface Table for the physical
+ port on which this OAM traffic flows."
+ ::= { nbsEfmOamEntry 1 }
+
+nbsEfmOamIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ifIndex from the MIB-II Interface Table for this OAM
+ interface."
+ ::= {nbsEfmOamEntry 2 }
+
+nbsEfmOamPeerIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ifIndex from the MIB-II Interface Table for the physical
+ port on the other side of the OAM link. For
+ example, if this table entry corresponds to a local
+ OAM device, this object would hold the ifIndex of the
+ remote port."
+ ::= { nbsEfmOamEntry 3 }
+
+nbsEfmOamMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ notSupported (1),
+ passive (2),
+ active (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A GET operation returns the current mode of the OAM
+ sublayer entity (see 57.2.6), either passive or
+ active. A SET operation changes the mode of operation
+ of the OAM entity to the indicated value. A SET
+ operation shall have no effect on a device whose mode
+ cannot be changed through management or that can only
+ operate in a single mode."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 4 }
+
+
+-- nbsEfmOamRemoteMACAddress OBJECT-TYPE
+-- SYNTAX MacAddress
+-- ACCESS read-only
+-- STATUS mandatory
+-- DESCRIPTION
+-- "The value of the source-address parameter of the last
+-- OAMPDU passed by the OAM subordinate sublayer to the OAM
+-- sublayer. This value is updated on reception of a valid
+-- frame with (1) a destinationField equal to the reserved
+-- multicast address for Slow-Protocols specified in CROSS
+-- REF Table 43B-1, (2) lengthOrType field value equal to
+-- the reserved Type for Slow-Protocols as specified in
+-- CROSS REF Table 43B-2, (3) a Slow-Protocols subtype
+-- value equal to the subtype reserved for OAM as specified
+-- in Table 43B-3."
+-- ::= {nbsEfmOamEntry 4 }
+
+nbsEfmOamCfg OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string of three bits corresponding to the OAM
+ Configuration field (see Table 57-7) in the most recently
+ received Information OAMPDU. The first bit corresponds to
+ the OAM Mode bit in the OAM Configuration field. The
+ second bit corresponds to the Unidirectional Support bit
+ in the OAM Configuration field. The third bit corresponds
+ to the Loopback Support bit in the OAM Configuration
+ field.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ the OAM code equals the OAM Information code."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 5 }
+
+nbsEfmOamPduCfg OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An eleven bit value corresponding to the Maximum PDU Size
+ value within the OAMPDU Configuration field (see Table
+ 57-8) in the most recently sent Information OAMPDU.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ the OAM code equals the OAM Information code."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 6 }
+
+nbsEfmOamFlagsField OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string of five bits corresponding to the Flags field
+ (see Table 57-3) in the most recently transmitted OAMPDU.
+ The first bit corresponds to the Link Fault bit in the
+ Flags field. The second bit corresponds to the Dying Gasp
+ bit in the Flags field. The third bit corresponds to the
+ Critical Event bit in the Flags field. The fourth bit
+ corresponds to the Remote Stable bit in the Flags field.
+ The fifth bit corresponds to the Local Stable bit in the
+ Flags field."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 7 }
+
+
+nbsEfmOamState OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string of three bits corresponding to the State field
+ (see Table 57-6) of the most recently sent Information
+ OAMPDU. The first and second bits corresponds to the
+ Parser Action bits in the State field. The third bit
+ corresponds to the Multiplexer Action bit in the State
+ field.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ a OAMPDU code equal to the Information code as specified
+ in Table 57-4."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 8 }
+
+nbsEfmOamVendorOUI OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of the OUI variable in the Vendor Identifier
+ field (see Table 57-9) of the most recently sent
+ Information OAMPDU.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ a OAMPDU code equal to the Information code as specified
+ in Table 57-4."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 9 }
+
+nbsEfmOamVendorDeviceId OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of the Device Identifier variable in the Vendor
+ Identifier field (see Table 57-9) of the most recently
+ sent Information OAMPDU.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ a OAMPDU code equal to the Information code as specified
+ in Table 57-4."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 10 }
+
+nbsEfmOamVendorDeviceVersion OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of the Version Identifier variable in the
+ Vendor Identifier field (see Table 57-9) of the most
+ recently sent Information OAMPDU.
+ This value is updated on reception of a valid frame, with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ a OAMPDU code equal to the Information code as specified
+ in Table 57-4."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 11 }
+
+nbsEfmOamPDUTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate sublayer
+ for transmission. This counter is incremented when a
+ OAM:MA_DATA.request service service primitive is generated
+ within the OAM sublayer."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 12 }
+
+nbsEfmOamPDURx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed by the OAM subordinate sublayer
+ to the OAM sublayer. This counter is incremented on
+ reception of a valid frame with (1) a destinationField
+ equal to the reserved multicast address for Slow_Protocols
+ specified in CROSS REF Table 43B-1, (2) lengthOrType field
+ value equal to the reserved Type for Slow_Protocols as
+ specified in CROSS REF Table 43B-2, (3) a Slow_Protocols
+ subtype value equal to the subtype reserved for OAM as
+ specified in Table 43B-3."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 13 }
+
+nbsEfmOamUnsupportedCodesRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain an OAM code from
+ Table 57-4 that are not supported by the device. This
+ counter is incremented on reception of a valid frame with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ an OAM code for a function that is not supported by the
+ device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 14 }
+
+nbsEfmOamInformationTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate sublayer
+ for transmission that contain the OAM Information code
+ specified in Table CROSS REF 57-4. This counter is
+ incremented when a OAM:MA_DATA.request service primitive
+ is generated within the OAM sublayer with an OAM code
+ indicating an OAM Information operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 15 }
+
+nbsEfmOamInformationRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain the OAM
+ Information code specified in Table 57-4. This
+ counter is incremented on reception of a valid frame with
+ (1) destinationField equal to the reserved multicast
+ address for Slow_Protocols specified in CROSS REF Table
+ 43B-1, (2) lengthOrType field value equal to the reserved
+ Type for Slow_Protocols as specified in CROSS REF Table
+ 43B-2, (3) a Slow_Protocols subtype value equal to the
+ subtype reserved for OAM as specified in Table 43B-3, (4)
+ an OAM code for a function that is not supported by the
+ device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 16 }
+
+nbsEfmOamEventNotificationTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate sublayer
+ for transmission that contain the Event Notification code
+ specified in Table 57-4. This counter is incremented when
+ a OAM:MA_DATA.request service primitive is generated
+ within the OAM sublayer with an OAM code indicating an
+ Event Notification operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 17 }
+
+
+nbsEfmOamUniEventNotificationRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the OAMPDUs received that contain the Event
+ Notification code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in CROSS REF Table 43B-3,
+ (4) the OAM code equals the Event Notification code, (5)
+ the Sequence Number field is not equal to the Sequence
+ Number field of the last received Event Notification
+ OAMPDU and is supported by the device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 18 }
+
+nbsEfmOamDupEventNotificationRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the OAMPDUs received that contain the Event
+ Notification code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in CROSS REF Table 43B-3,
+ (4) the OAM code equals the Event Notification code, (5)
+ the Sequence Number field is equal to the Sequence
+ Number field of the last received Event Notification
+ OAMPDU."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 19 }
+
+nbsEfmOamLoopbackControlTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate
+ sublayer for transmission that contain the Loopback
+ Control code specified in Table 57-4. This counter is
+ incremented when a OAM:MA_DATA.request service primitive
+ is generated within the OAM sublayer with an OAM code
+ indicating a Loopback Control operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 20 }
+
+
+nbsEfmOamLoopbackControlRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain the Loopback
+ Control code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in Table 43B-3, (4) the OAM
+ code equals the Loopback Control code and is supported by
+ the device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 21 }
+
+nbsEfmOamVariableRequestTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate sublayer
+ for transmission that contain the Variable Request code
+ specified in Table 57-4. This counter is incremented when
+ a OAM:MA_DATA.request service primitive is generated
+ within the OAM sublayer with an OAM code indicating a
+ Variable Request operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 22 }
+
+nbsEfmOamVariableRequestRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain the Variable
+ Request code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in Table 43B-3, (4) the OAM
+ code equals the Variable Request code and is supported by
+ the device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 23 }
+
+nbsEfmOamVariableResponseTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs passed to the OAM subordinate sublayer
+ for transmission that contain the Variable Response code
+ specified in Table 57-4. This counter is incremented when
+ a OAM:MA_DATA.request service primitive is generated
+ within the OAM sublayer with an OAM code indicating a
+ Variable Response operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 24 }
+
+nbsEfmOamVariableResponseRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain the Variable
+ Response code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in Table 43B-3, (4) the OAM
+ code equals the Variable Response code and is supported by
+ the device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 25 }
+
+nbsEfmOamOrganizationSpecificTx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of Organization Specific OAMPDUs passed to the
+ OAM subordinate sublayer for transmission that contain the
+ Organization Specific code specified in Table 57-4. This
+ counter is incremented when a OAM:MA_DATA.request service
+ primitive is generated within the OAM sublayer with an OAM
+ code indicating a Organization Specific operation."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 26 }
+
+nbsEfmOamOrganizationSpecificRx OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of OAMPDUs received that contain the Organization
+ Specific code specified in Table 57-4. This counter is
+ incremented on reception of a valid frame, with (1)
+ destinationField equal to the reserved multicast address
+ for Slow_Protocols specified in CROSS REF Table 43B-1, (2)
+ lengthOrType field value equal to the reserved Type for
+ Slow_Protocols as specified in CROSS REF Table 43B-2, (3)
+ a Slow_Protocols subtype value equal to the subtype
+ reserved for OAM as specified in Table 43B-3, (4) the OAM
+ code equals the Organization Specific code and is
+ supported by the device."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 27 }
+
+nbsEfmOamErrSymPerCfgDuration OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An eight-octet value indicating the duration of the
+ Errored Symbol Period Event (see 57.5.3.1) window, in
+ terms of symbols."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 28 }
+
+nbsEfmOamErrSymPerCfgThreshld OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A four-octet value indicating the number of errored
+ symbols in the period that must be exceeded in order for
+ the Errored Symbol Period Event to be generated."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 29 }
+
+nbsEfmOamErrSymPerEvtTime OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Event Time Stamp field in
+ the most recently transmitted Errored Symbol Period Event
+ TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Symbol Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 30 }
+
+nbsEfmOamErrSymPerEvtWindow OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Symbol Window
+ field in the most recently transmitted Errored Symbol
+ Period Event TLV in an Event Notification OAMPDU (see
+ 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Symbol Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 31 }
+
+nbsEfmOamErrSymPerEvtThreshld OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Symbol Threshold
+ field in the most recently transmitted Errored Symbol
+ Period Event TLV in an Event Notification OAMPDU (see
+ 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Symbol Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 32 }
+
+nbsEfmOamErrSymPerEvtCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Error Running Total field
+ in the most recently transmitted Errored Symbol Period
+ Event TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Symbol Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 33 }
+
+nbsEfmOamErrFrmCfgDuration OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A four-octet value indicating the duration of the Errored
+ Frame Event (see 57.5.3.2) window, in terms of number of
+ 100ms intervals."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 34 }
+
+nbsEfmOamErrFrmCfgThreshld OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A four-octet field indicating the number of errored
+ frames in the period that must be exceeded in order for
+ the Errored Frame Event to be generated."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 35 }
+
+nbsEfmOamErrFrmEvtTime OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Event Time Stamp field in
+ the most recently transmitted Errored Frame Event TLV in
+ an Event Notification OAMPDU (see 57.4.3.2). This integer
+ is updated when a OAM:MA_DATA.request service primitive is
+ generated within the OAM sublayer with an OAMPDU Code
+ field value equal to the Event Notification code as
+ specified in Table 57-4 and Event TLV Type field equal to
+ the Errored Frame Event value as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 36 }
+
+nbsEfmOamErrFrmEvtWindow OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Window
+ field in the most recently transmitted Errored Frame
+ Event TLV in an Event Notification OAMPDU (see
+ 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Event value as
+ specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 37 }
+
+nbsEfmOamErrFrmEvtThreshld OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Threshold
+ field in the most recently transmitted Errored Frame Event
+ TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Event value as
+ specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 38 }
+
+nbsEfmOamErrFrmEvtCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Error Running Total field
+ in the most recently transmitted Errored Frame Event TLV
+ in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Event value as
+ specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 39 }
+
+nbsEfmOamErrFrmPerCfgDuration OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A four-octet value indicating the duration of the Errored
+ Frame Period Event (see 57.5.3.3) window, in terms of the
+ number of minFrameSize frames that can be transmitted on
+ the underlying physical layer."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 40 }
+
+nbsEfmOamErrFrmPerCfgThreshld OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A four-octet value indicating the number of errored
+ frames in the period that must be exceeded in order for
+ the Errored Frame Period Event to be generated."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 41 }
+
+nbsEfmOamErrFrmPerEvtTime OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Event Time Stamp field
+ in the most recently transmitted Errored Frame Period
+ Event TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 42 }
+
+nbsEfmOamErrFrmPerEvtWindow OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Window field
+ in the most recently transmitted Errored Frame Period
+ Event TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 43 }
+
+nbsEfmOamErrFrmPerEvtThreshld OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Threshold field
+ in the most recently transmitted Errored Frame Period
+ Event TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 44 }
+
+nbsEfmOamErrFrmPerEvtCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Error Running Total field
+ in the most recently transmitted Errored Frame Period
+ Event TLV in an Event Notification OAMPDU (see 57.4.3.2).
+ This integer is updated when a OAM:MA_DATA.request
+ service primitive is generated within the OAM sublayer
+ with an OAMPDU Code field value equal to the Event
+ Notification code as specified in Table 57-4 and Event TLV
+ Type field equal to the Errored Frame Period Event value
+ as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 45 }
+
+nbsEfmOamErrFrmSecSumCfgDuration OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A two-octet value indicating the duration of the Errored
+ Frame Seconds Summary Event (see 57.5.3.4) window, in
+ terms of number of 100ms intervals."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 46 }
+
+nbsEfmOamErrFrmSecSumCfgThreshld OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A two-octet value indicating the number of errored frame
+ seconds in the period that must be exceeded in order for
+ the Errored Frame Seconds Summary Event to be generated."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 47 }
+
+nbsEfmOamErrFrmSecSumEvtTime OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Event Time Stamp field
+ in the most recently transmitted Errored Frame Seconds
+ Summary Event TLV in an Event Notification OAMPDU (see
+ 57.4.3.2). This integer is updated when a
+ OAM:MA_DATA.request service primitive is generated within
+ the OAM sublayer with an OAMPDU Code field value equal to
+ the Event Notification code as specified in Table 57-4 and
+ Event TLV Type field equal to the Errored Frame Seconds
+ Summary Event value as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 48 }
+
+nbsEfmOamErrFrmSecSumEvtWindow OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Seconds
+ Window field in the most recently transmitted Errored
+ Frame Seconds Summary Event TLV in an Event Notification
+ OAMPDU (see 57.4.3.2). This integer is updated when a
+ OAM:MA_DATA.request service primitive is generated within
+ the OAM sublayer with an OAMPDU Code field value equal to
+ the Event Notification code as specified in Table 57-4 and
+ Event TLV Type field equal to the Errored Frame Seconds
+ Summary Event value as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 49 }
+
+nbsEfmOamErrFrmSecSumEvtThreshld OBJECT-TYPE
+ SYNTAX Unsigned16TC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Errored Frame Seconds
+ Threshold field in the most recently transmitted Errored
+ Frame Seconds Summary Event TLV in an Event Notification
+ OAMPDU (see 57.4.3.2). This integer is updated when a
+ OAM:MA_DATA.request service primitive is generated within
+ the OAM sublayer with an OAMPDU Code field value equal to
+ the Event Notification code as specified in Table 57-4 and
+ Event TLV Type field equal to the Errored Frame Seconds
+ Summary Event value as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 50 }
+
+nbsEfmOamErrFrmSecSumEvtCount OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An integer corresponding to the Error Running Total field
+ in the most recently transmitted Errored Frame Seconds
+ Summary Event TLV in an Event Notification OAMPDU (see
+ 57.4.3.2). This integer is updated when a
+ OAM:MA_DATA.request service primitive is generated within
+ the OAM sublayer with an OAMPDU Code field value equal to
+ the Event Notification code as specified in Table 57-4 and
+ Event TLV Type field equal to the Errored Frame Seconds
+ Summary Event value as specified in Table 57-10."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= {nbsEfmOamEntry 51 }
+
+nbsEfmOamFramesLostDueToOamError OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of frames that would otherwise be transmitted by
+ the OAM sublayer, but could not be due to an internal OAM
+ sublayer transmit error. If this counter is incremented,
+ then none of the other counters in this section are
+ incremented. The exact meaning and mechanism for
+ incrementing this counter is implementation dependent."
+ REFERENCE "IEEE 802.3ah, Clause 57"
+ ::= { nbsEfmOamEntry 52 }
+
+nbsEfmOamAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notSupported (1),
+ disable (2),
+ enable (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A value that identifies the operational state of the OAM
+ sublayer. An interface which can provide the OAM sublayer
+ functions specified in Clause 57 will be enabled to do so
+ when this attribute has the enumeration enable(3). When
+ this attribute has the enumeration disable(2) the interface
+ will act as it would if it had no OAM sublayer."
+ DEFVAL { enable }
+ ::= {nbsEfmOamEntry 53 }
+
+nbsEfmOamOperState OBJECT-TYPE
+
+ SYNTAX OCTET STRING(SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object declares configurable (*) and operational reasons for
+ disabling OAM service. The reason applies only if the bit is set.
+ Multiple bits may be set concurrently. OAM service is enabled
+ when no bits are set.
+
+ Bit Reason to disable
+ --- ----------------------------------------------
+ 0 reserved
+ 1 reserved
+ 2 reserved
+ 3 reserved
+ 4 reserved
+ 5 Temporarily disabled for download processing
+ 6 Administratively disabled (*)
+ 7 OAM service is not available
+
+ OCTET STRING bitmasks count the leftmost bit (MSB) as 0."
+
+ ::= {nbsEfmOamEntry 54 }
+
+
+
+
+
+-- ***********************************************************************
+-- Conformance information.
+-- ***********************************************************************
+nbsEfmConformance OBJECT IDENTIFIER ::= { nbsEfmMib 3 }
+nbsEfmGroups OBJECT IDENTIFIER ::= { nbsEfmConformance 1 }
+
+-- units of conformance
+nbsEfmOamGroup OBJECT-GROUP
+OBJECTS {
+ nbsEfmPhysicalIfIndex,
+ nbsEfmOamIfIndex,
+ nbsEfmOamPeerIfIndex,
+ nbsEfmOamMode,
+ nbsEfmOamCfg,
+ nbsEfmOamPduCfg,
+ nbsEfmOamFlagsField,
+ nbsEfmOamState,
+ nbsEfmOamVendorOUI,
+ nbsEfmOamVendorDeviceId,
+ nbsEfmOamVendorDeviceVersion,
+ nbsEfmOamPDUTx,
+ nbsEfmOamPDURx,
+ nbsEfmOamUnsupportedCodesRx,
+ nbsEfmOamInformationTx,
+ nbsEfmOamInformationRx,
+ nbsEfmOamEventNotificationTx,
+ nbsEfmOamUniEventNotificationRx,
+ nbsEfmOamDupEventNotificationRx,
+ nbsEfmOamLoopbackControlTx,
+ nbsEfmOamLoopbackControlRx,
+ nbsEfmOamVariableRequestTx,
+ nbsEfmOamVariableRequestRx,
+ nbsEfmOamVariableResponseTx,
+ nbsEfmOamVariableResponseRx,
+ nbsEfmOamOrganizationSpecificTx,
+ nbsEfmOamOrganizationSpecificRx,
+ nbsEfmOamErrSymPerCfgDuration,
+ nbsEfmOamErrSymPerCfgThreshld,
+ nbsEfmOamErrSymPerEvtTime,
+ nbsEfmOamErrSymPerEvtWindow,
+ nbsEfmOamErrSymPerEvtThreshld,
+ nbsEfmOamErrSymPerEvtCount,
+ nbsEfmOamErrFrmCfgDuration,
+ nbsEfmOamErrFrmCfgThreshld,
+ nbsEfmOamErrFrmEvtTime,
+ nbsEfmOamErrFrmEvtWindow,
+ nbsEfmOamErrFrmEvtThreshld,
+ nbsEfmOamErrFrmEvtCount,
+ nbsEfmOamErrFrmPerCfgDuration,
+ nbsEfmOamErrFrmPerCfgThreshld,
+ nbsEfmOamErrFrmPerEvtTime,
+ nbsEfmOamErrFrmPerEvtWindow,
+ nbsEfmOamErrFrmPerEvtThreshld,
+ nbsEfmOamErrFrmPerEvtCount,
+ nbsEfmOamErrFrmSecSumCfgDuration,
+ nbsEfmOamErrFrmSecSumCfgThreshld,
+ nbsEfmOamErrFrmSecSumEvtTime,
+ nbsEfmOamErrFrmSecSumEvtWindow,
+ nbsEfmOamErrFrmSecSumEvtThreshld,
+ nbsEfmOamErrFrmSecSumEvtCount,
+ nbsEfmOamFramesLostDueToOamError,
+ nbsEfmOamAdminState,
+ nbsEfmOamOperState
+}
+STATUS current
+DESCRIPTION
+ "OAM attributes."
+::= { nbsEfmGroups 3 }
+
+END