diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/meinberg/MBG-SNMP-LT-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/meinberg/MBG-SNMP-LT-MIB')
| -rwxr-xr-x | MIBS/meinberg/MBG-SNMP-LT-MIB | 4111 |
1 files changed, 4111 insertions, 0 deletions
diff --git a/MIBS/meinberg/MBG-SNMP-LT-MIB b/MIBS/meinberg/MBG-SNMP-LT-MIB new file mode 100755 index 0000000..23c180c --- /dev/null +++ b/MIBS/meinberg/MBG-SNMP-LT-MIB @@ -0,0 +1,4111 @@ +-- ************************************************************************** +-- +-- $Id: MBG-LANTIME-MIB.mib 1.1 2012/08/31 06:25:09 philipp TRASH $ +-- $Name: $ +-- +-- Copyright (c) Meinberg Funkuhren, 31812 Bad Pyrmont, Germany +-- +-- Description: +-- Management Information Base for Meinberg LANTIME time server +-- +-- ************************************************************************** +-- +-- $Log: MBG-LANTIME-MIB.mib $ +-- Revision 1.1 2012/08/31 06:25:09 philipp +-- Revision 1.9 2011/30/03 12:00:00 philipp +-- - added mbgLtPtp and PTP traps objects +-- Revision 1.8 2011/28/02 10:12:45 heiko +-- - added PTP objects +-- Revision 1.7 2008/09/11 08:05:53 heiko +-- - added MRS objects and Traps +-- Revision 1.3.1.1 2008/09/10 13:18:48 heiko +-- - 5.26e added MRS (XMR) Objects and Traps +-- Revision 1.3 2006/08/24 13:07:55 heiko +-- - now up to 7 external NTP servers +-- - "prefer" flag can be set for each external NTP server +-- - renumbered the remaining objects in mbgLtCfgNtp +-- Revision 1.2 2006/08/23 09:51:05 heiko +-- - new object mbgLtCmdSetRefTime for setting the time of the refclock via SNMP +-- Revision 1.1 2006/08/23 09:35:41 heiko +-- +-- ************************************************************************** + +MBG-SNMP-LT-MIB DEFINITIONS ::= BEGIN + + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE , Integer32, NOTIFICATION-TYPE + FROM SNMPv2-SMI + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP + FROM SNMPv2-CONF + DisplayString FROM SNMPv2-TC + + mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB; + + +mbgLantime MODULE-IDENTITY + LAST-UPDATED "201201250745Z" + ORGANIZATION "www.meinberg.de" + CONTACT-INFO + "postal: Meinberg Funkuhren + Lange Wand 9 + 31812 Bad Pyrmont + Germany + + email: info@meinberg.de" + DESCRIPTION + " Meinberg SNMP Management Information Base " + REVISION "201201250745Z" + DESCRIPTION + " Changed MIB module name." + REVISION "201103300000Z" + DESCRIPTION + " Version 5.32l, added mbgLtPtp and PTP traps objects" + REVISION "201103290000Z" + DESCRIPTION + " Version 5.32c, added mbgLtPtp Branch with PTP information objects " + REVISION "201001190000Z" + DESCRIPTION + " Revised edition (V5.30i), added NTP Sync Trap definition" + REVISION "200912030000Z" + DESCRIPTION + " Revised edition (V5.30g), added NTP Client Monitoring Trap definition" + REVISION "200809100000Z" + DESCRIPTION + "Revised edition (V5.26e), added MRS Objects and Traps" + REVISION "200807150000Z" + DESCRIPTION + "Revised edition (V5.26), added ReceiverSync Trap (14)" + REVISION "200806150000Z" + DESCRIPTION + "Revised edition (V5.25), changed postal address" + REVISION "200608230000Z" + DESCRIPTION + "Revised edition (V4.38), added mbgLtCmdSetRefTime" + REVISION "200603200000Z" + DESCRIPTION + "Revised edition (V4.36) with changed Trap OID base" + REVISION "200507080000Z" + DESCRIPTION + "Revised edition (V4.25)" + ::= { mbgSnmpRoot 3 } + +-- +-- General LANTIME information objects +-- + +mbgLtInfo OBJECT IDENTIFIER ::= { mbgLantime 0 } + +mbgLtFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the installed firmware version of your LANTIME" + ::= { mbgLtInfo 1 } + +mbgLtFirmwareVersionVal OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the installed firmware version of your LANTIME as an Integer32 value" + ::= { mbgLtInfo 2 } + + +-- +-- Lantime NTP states +-- +mbgLtNtp OBJECT IDENTIFIER ::= { mbgLantime 1 } + + + +mbgLtNtpCurrentState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "actual state of the NTP as string" + --- possible strings: + --- "not synchronized" + --- "no good refclock (->local)" + --- "sync to external refclock" + --- "sync to serial refclock" + --- "Normal Operation (->PPS)" + --- "Normal Operation (->internal refclock)" + --- internal refclocks (PlugIn cards) have to be linked + --- via /dev/refclock-2 and /dev/refclock-3 + ::= { mbgLtNtp 1 } + +mbgLtNtpCurrentStateVal OBJECT-TYPE + SYNTAX INTEGER { + notSynchronized(0), + noGoodRefclock(1), + syncToExtRefclock(2), + syncToSerialRefclock(3), + normalOperationPPS(4), + normalOperationRefclock(5), + unknown(99) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current state of the NTP as Integer32 value" + --- "0 : not synchronized" + --- "1 : no good refclock (->local)" + --- "2 : sync to external refclock" + --- "3 : sync to serial refclock" + --- "4 : Normal Operation (->PPS)" + --- "5 : Normal Operation (->internal refclock)" + DEFVAL { 99 } + ::= { mbgLtNtp 2 } + +mbgLtNtpStratum OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Stratum value of the NTP " + DEFVAL { 99 } + ::= { mbgLtNtp 3 } + +mbgLtNtpActiveRefclockId OBJECT-TYPE + SYNTAX INTEGER { + localClock(0), + serialRefclock(1), + pps(2), + externalRefclock(3), + notSync(99) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index of the current refclock selected by the NTP " + --- "0 : local clock" + --- "1 : serial refclock + --- "2 : PPS (Lantime/RD: second serial refclock" + --- "3 : external Refclock (Lantime/RD: PPS) + --- "99: NTP has not sync to any refclock" + DEFVAL { 99 } + ::= { mbgLtNtp 4 } + +mbgLtNtpActiveRefclockName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of the current refclock selected by the NTP " + ::= { mbgLtNtp 5 } + +mbgLtNtpActiveRefclockOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time offset between the current selected refclock and time of NTP as string" + ::= { mbgLtNtp 6 } + +mbgLtNtpActiveRefclockOffsetVal OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time offset in micro seconds between the current selected refclock and time of NTP " + DEFVAL { 1024000000 } + ::= { mbgLtNtp 7 } + +mbgLtNtpNumberOfRefclocks OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of refclocks configured in the NTP " + DEFVAL { 0 } + ::= { mbgLtNtp 8 } + +mbgLtNtpAuthKeyId OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Authentication Key ID of active refclock is active " + DEFVAL { 0 } + ::= { mbgLtNtp 9 } + +mbgLtNtpVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "integrated NTP version " + ::= { mbgLtNtp 10 } + + +-- +-- Lantime Refclock states +-- + +mbgLtRefclock OBJECT IDENTIFIER ::= { mbgLantime 2 } + +mbgLtRefClockType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of refclock connected to NTP time server " + ::= { mbgLtRefclock 1 } + +mbgLtRefClockTypeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + mbgGPS167(1), + mbgGPS167BGTTGP(2), + mbgPZF509(3), + mbgPZF509BGTTGP(4), + mbgSHS(5), + mbgSHSBGT(6), + mbgSHSFRC(7), + mbgSHSFRCBGT(8), + mbgTCR509(9), + mbgTCR509BGTTGP(10), + mbgRDT(11), + mbgRDTBGTTGP(12), + mbgEDT(13), + mbgEDTBGTTGP(14), + mbgAHS(15), + mbgDHS(16), + mbgNDT167(17), + mbgNDT167BGT(18), + mbgDCT(19), + mbgDCTBGT(20), + mbgSHSTCR(21), + mbgSHSTCRBGT(22) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: GPS167 1HE" + --- " 2: GPS167 BGT/TGP" + --- " 3: PZF509 1HE" + --- " 4: PZF509 BGT/TGP" + --- " 5: SHS 1HE" + --- " 6: SHS BGT" + --- " 7: SHS-FRC 1HE" + --- " 8: SHS-FRC BGT" + --- " 9: TCR509 1HE" + --- "10: TCR509 BGT/TGP" + --- "11: RDT 1HE" + --- "12: RDT BGT/TGP" + --- "13: EDT 1HE" + --- "14: EDT BGT/TGP" + --- "15: AHS" + --- "16: DHS" + --- "17: NDT167 1HE" + --- "18: NDT167 BGT" + --- "19: DCT 1HE" + --- "20: DCT BGT" + --- "21: SHS-TCR 1HE" + --- "22: SHS-TCR BGT" + + + DEFVAL { 0 } + ::= { mbgLtRefclock 2 } + + +mbgLtRefClockMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current mode of refclock connected to NTP time server " + ::= { mbgLtRefclock 3 } + +mbgLtRefClockModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + normalOperation(1), + trackingSearching(2), + antennaFaulty(3), + warmBoot(4), + coldBoot(5), + antennaShortcircuit(6) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current mode of refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: Normal Operation" + --- " 2: Tracking/Searching" + --- " 3: Antenna Faulty" + --- " 4: Warm Boot" + --- " 5: Cold Boot" + --- " 6: Antenna Short Circuit" + DEFVAL { 0 } + ::= { mbgLtRefclock 4 } + +mbgLtRefGpsState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of GPS refclock conneted to NTP time server " + ::= { mbgLtRefclock 5 } + +mbgLtRefGpsStateVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + synchronized(1), + notsynchronized(2) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of GPS refclock conneted to NTP time server as value" + --- " 0: not available" + --- " 1: synchronized" + --- " 2: not synchronized" + DEFVAL { 0 } + ::= { mbgLtRefclock 6 } + +mbgLtRefGpsPosition OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Position of GPS refclock conneted to NTP time server " + ::= { mbgLtRefclock 7 } + +mbgLtRefGpsSatellites OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Satellites in view and good of GPS refclock connected to NTP time server " + ::= { mbgLtRefclock 8 } + +mbgLtRefGpsSatellitesGood OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current good Satellites of GPS refclock connected to NTP time server as value" + ::= { mbgLtRefclock 9 } + +mbgLtRefGpsSatellitesInView OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Satellites in view of GPS refclock conneted to NTP time server as value" + ::= { mbgLtRefclock 10 } + +mbgLtRefPzfState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of DCF77/PZF refclock connected to NTP time server " + ::= { mbgLtRefclock 11 } + +mbgLtRefPzfStateVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + sync(1), + notsyncnow(2), + neversynced(3) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of DCF77/PZF refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: sync" + --- " 2: not sync now" + --- " 3: never synced" + DEFVAL { 0 } + ::= { mbgLtRefclock 12 } + +mbgLtRefPzfKorrelation OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Korrelation of DCF77/PZF refclock connected to NTP time server " + --- " 0: not available" + --- " 254: Antenna Faulty" + --- " 255: Gsync" + --- " minimum of 60 to get synchronization" + --- " optimal value of 75" + DEFVAL { 0 } + ::= { mbgLtRefclock 13 } + +mbgLtRefPzfField OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current strength of field of DCF77/PZF refclock connected to NTP time server " + --- " 0: not available" + DEFVAL { 0 } + ::= { mbgLtRefclock 14 } + + +mbgLtRefGpsMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of GPS refclock connected to NTP time server " + ::= { mbgLtRefclock 15 } + +mbgLtRefGpsModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + normalOperation(1), + trackingSearching(2), + antennaFaulty(3), + warmBoot(4), + coldBoot(5), + antennaShortcircuit(6) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of GPS refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: Normal Operation" + --- " 2: Tracking/Searching" + --- " 3: Antenna Faulty" + --- " 4: Warm Boot" + --- " 5: Cold Boot" + --- " 6: Antenna Short Circuit" + --- This variable was formerly known as mbgLtRefClockModeVal + DEFVAL { 0 } + ::= { mbgLtRefclock 16 } + +mbgLtRefIrigMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of IRIG refclock conneted to NTP time server " + ::= { mbgLtRefclock 17 } + +mbgLtRefIrigModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + locked(1), + notlocked(2), + telegramError(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of IRIG refclock conneted to NTP time server as value" + --- " 0: not available" + --- " 1: Sync (locked)" + --- " 2: Not sync (not locked)" + --- " 3: Telegram error" + DEFVAL { 0 } + ::= { mbgLtRefclock 18 } + + +mbgLtRefPzfMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of PZF refclock connected to NTP time server " + ::= { mbgLtRefclock 19 } + +mbgLtRefPzfModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + normalOperation(1), + antennaFaulty(2) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of PZF refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: Normal Operation" + --- " 2: Antenna Faulty" + DEFVAL { 0 } + ::= { mbgLtRefclock 20 } + + +mbgLtRefIrigState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of IRIG refclock connected to NTP time server " + ::= { mbgLtRefclock 21 } + +mbgLtRefIrigStateVal OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of IRIG refclock connected to NTP time server as value" + --- Please refer to manual for IRIG states. They are represented by set/unset bits, + --- so this value is a "binary" form combining all possible IRIG states of our IRIG refclock + DEFVAL { 0 } + ::= { mbgLtRefclock 22 } + +mbgLtRefSHSMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of SHS system connected to NTP time server " + ::= { mbgLtRefclock 23 } + +mbgLtRefSHSModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + normalOperation(1), + stoppedTimeLimitError(2) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of SHS system connected to NTP time server as value" + --- " 0: not available" + --- " 1: Normal Operation" + --- " 2: Stopped/Time Limit Error" + DEFVAL { 0 } + ::= { mbgLtRefclock 24 } + +mbgLtRefSHSTimeDiff OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current time difference between the two SHS reference time sources in miliseconds" + DEFVAL { 0 } + ::= { mbgLtRefclock 25 } + +mbgLtRefDctState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of DCF77 refclock connected to NTP time server " + ::= { mbgLtRefclock 26 } + +mbgLtRefDctStateVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + sync(1), + notsyncnow(2), + neversynced(3) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current State of DCF77 refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: sync" + --- " 2: not sync now" + --- " 3: never synced" + DEFVAL { 0 } + ::= { mbgLtRefclock 27 } + +mbgLtRefDctField OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current strength of field of DCF77 refclock connected to NTP time server " + --- " 0: not available" + DEFVAL { "0" } + ::= { mbgLtRefclock 28 } + +mbgLtRefDctMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of DCF77 refclock connected to NTP time server " + ::= { mbgLtRefclock 29 } + +mbgLtRefDctModeVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + normalOperation(1), + antennaFaulty(2) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "current Mode of DCF77 refclock connected to NTP time server as value" + --- " 0: not available" + --- " 1: Normal Operation" + --- " 2: Antenna Faulty" + DEFVAL { 0 } + ::= { mbgLtRefclock 30 } + + + +mbgLtRefGpsLeapSecond OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Date and Time of leap second announcement received via GPS" + ::= { mbgLtRefclock 31 } + +mbgLtRefGpsLeapCorrection OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Leap Second Correction received via GPS" + --- Possible values are: + --- -1 (negative leap second, never happened so far) + --- 0 (no leap second announcement received) + --- 1 (positive leap second, will be inserted between 23:59:59 on the the leap second date + --- and 00:00:00 on the day after the leap second date + DEFVAL { 0 } + ::= { mbgLtRefclock 32 } + +-- +-- MRS (Multi Reference Source) Section +-- +mbgLtMrs OBJECT IDENTIFIER ::= { mbgLtRefclock 50 } + +mbgLtRefMrsRef OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ID of currently active reference source as a string" + -- Examples: gps,ntp,irig,pps,frequency,ptp + + ::= { mbgLtMrs 1 } + + +mbgLtRefMrsRefVal OBJECT-TYPE + SYNTAX INTEGER { + notavailable(0), + refGps(1), + refIrig(2), + refPps(3), + refFreq(4), + refPtp(5), + refNtp(6), + refFreeRun(99) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "currently active reference as a value" + -- 0: not available (no MRS/initializing) + -- 1: GPS + -- 2: IRIG (Time Code, both DCLS and AM possible) + -- 3: PPS (Pulse Per Second) + -- 4: Frequency (e.g. 10MHz) + -- 5: PTP/IEEE1588 (synchronized by a PTP Grandmaster) + -- 6: NTP/Network Time Protocol (synchronized by an NTP server) + -- 99: Free running (no sync source, internal oscillator is freewheeling) + + ::= { mbgLtMrs 2 } + + +mbgLtRefMrsRefList OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of all supported MRS references in a comma separated list" + -- Example: "gps,irig,ntp,ptp,pps,freq" + + ::= { mbgLtMrs 3 } + + +mbgLtRefMrsPrioList OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of all active MRS references in a comma separated list sorted by priority" + -- Example: "gps,irig,ntp,ptp,pps,freq" + -- "active" means that a priority has been assigne to the reference + + ::= { mbgLtMrs 4 } + + +-- +-- MRS Reference Sources Status Section +-- +mbgLtMrsRef OBJECT IDENTIFIER ::= { mbgLtMrs 10 } + +mbgLtMrsRefGps OBJECT IDENTIFIER ::= { mbgLtMrsRef 1 } + +mbgLtMrsGpsOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefGps 1 } + +mbgLtMrsGpsOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefGps 2 } + +mbgLtMrsGpsOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsGpsOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsGpsOffsVal with + -- 10^(-x) where x is mbgLtMrsGpsOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefGps 3 } + + +mbgLtMrsGpsPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefGps 4 } + + +mbgLtMrsGpsState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefGps 5 } + +mbgLtMrsGpsStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefGps 6 } + + +mbgLtMrsGpsPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefGps 7 } + + +-- +-- IRIG reference source (for both AM and DCLS input interfaces) +-- +mbgLtMrsRefIrig OBJECT IDENTIFIER ::= { mbgLtMrsRef 2 } + +mbgLtMrsIrigOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefIrig 1 } + +mbgLtMrsIrigOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefIrig 2 } + +mbgLtMrsIrigOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsIrigOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsIrigOffsVal with + -- 10^(-x) where x is mbgLtMrsIrigOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefIrig 3 } + + +mbgLtMrsIrigPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefIrig 4 } + + +mbgLtMrsIrigState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefIrig 5 } + +mbgLtMrsIrigStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefIrig 6 } + +mbgLtMrsIrigCorr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Correction Value (Fixed Offset) of this reference in nanoseconds" + -- Example : "+100" + + ::= { mbgLtMrsRefIrig 7 } + +mbgLtMrsIrigOffsLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Offset Limit in nanoseconds, if exceeded this will trigger a notification" + -- Example : "100" + + ::= { mbgLtMrsRefIrig 8 } + +mbgLtMrsIrigPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefIrig 9 } + + +-- +-- PPS reference source +-- +mbgLtMrsRefPps OBJECT IDENTIFIER ::= { mbgLtMrsRef 3 } + +mbgLtMrsPpsOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefPps 1 } + +mbgLtMrsPpsOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefPps 2 } + +mbgLtMrsPpsOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsPpsOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsPpsOffsVal with + -- 10^(-x) where x is mbgLtMrsPpsOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefPps 3 } + + +mbgLtMrsPpsPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefPps 4 } + + +mbgLtMrsPpsState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefPps 5 } + +mbgLtMrsPpsStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefPps 6 } + + +mbgLtMrsPpsCorr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Correction Value (Fixed Offset) of this reference in nanoseconds" + -- Example : "+100" + + ::= { mbgLtMrsRefPps 7 } + +mbgLtMrsPpsOffsLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Offset Limit in nanoseconds, if exceeded this will trigger a notification" + -- Example : "100" + + ::= { mbgLtMrsRefPps 8 } + + +mbgLtMrsPpsPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefPps 9 } + + +-- +-- Frequency reference source (can be 10 MHz or 2048kHz) +-- +mbgLtMrsRefFreq OBJECT IDENTIFIER ::= { mbgLtMrsRef 4 } + +mbgLtMrsFreqOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefFreq 1 } + +mbgLtMrsFreqOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefFreq 2 } + +mbgLtMrsFreqOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsFreqOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsFreqOffsVal with + -- 10^(-x) where x is mbgLtMrsFreqOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefFreq 3 } + + +mbgLtMrsFreqPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefFreq 4 } + + +mbgLtMrsFreqState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefFreq 5 } + +mbgLtMrsFreqStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefFreq 6 } + +mbgLtMrsFreqCorr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Correction Value (Fixed Offset) of this reference in nanoseconds" + -- Example : "+100" + + ::= { mbgLtMrsRefFreq 7 } + +mbgLtMrsFreqOffsLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Offset Limit in nanoseconds, if exceeded this will trigger a notification" + -- Example : "100" + + ::= { mbgLtMrsRefFreq 8 } + +mbgLtMrsFreqPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefFreq 9 } + +-- +-- PTP/IEEE1588 reference source +-- +mbgLtMrsRefPtp OBJECT IDENTIFIER ::= { mbgLtMrsRef 5 } + +mbgLtMrsPtpOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefPtp 1 } + +mbgLtMrsPtpOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefPtp 2 } + +mbgLtMrsPtpOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsPtpOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsPtpOffsVal with + -- 10^(-x) where x is mbgLtMrsPtpOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefPtp 3 } + + +mbgLtMrsPtpPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefPtp 4 } + + +mbgLtMrsPtpState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefPtp 5 } + +mbgLtMrsPtpStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefPtp 6 } + + +mbgLtMrsPtpCorr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Correction Value (Fixed Offset) of this reference in nanoseconds" + -- Example : "+100" + + ::= { mbgLtMrsRefPtp 7 } + +mbgLtMrsPtpOffsLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Offset Limit in nanoseconds, if exceeded this will trigger a notification" + -- Example : "100" + + ::= { mbgLtMrsRefPtp 8 } + +mbgLtMrsPtpPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefPtp 9 } + +-- +-- NTP reference source +-- +mbgLtMrsRefNtp OBJECT IDENTIFIER ::= { mbgLtMrsRef 6 } + +mbgLtMrsNtpOffs OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit included in the string" + -- Example : "100.0ns" + + ::= { mbgLtMrsRefNtp 1 } + +mbgLtMrsNtpOffsVal OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset of this reference to the currently active reference, unit see below" + -- Example : "100" + + ::= { mbgLtMrsRefNtp 2 } + +mbgLtMrsNtpOffsBase OBJECT-TYPE + SYNTAX INTEGER { + baseSeconds(0), + baseMiliseconds(3), + baseMicroseconds(6), + baseNanoseconds(9) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "base of the offset value shown in mbgLtMrsNtpOffsVal" + -- In order to calculate the offset in seconds, multiply mbgLtMrsNtpOffsVal with + -- 10^(-x) where x is mbgLtMrsNtpOffsBase + -- Example: + -- mbgLtMrsOffsVal = 65 + -- mbgLtMrsOffsBase = 9 + -- Offset is 65*10^(-9) = 0.000000065 Seconds + + ::= { mbgLtMrsRefNtp 3 } + + +mbgLtMrsNtpPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the configured priority of this reference" + + ::= { mbgLtMrsRefNtp 4 } + + +mbgLtMrsNtpState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as a string" + -- Example: "is Master", "no signal" + + ::= { mbgLtMrsRefNtp 5 } + +mbgLtMrsNtpStateVal OBJECT-TYPE + SYNTAX INTEGER { + notAvailable(0), + notSupported(1), + notConnected(2), + noSignal(3), + hasLocked(4), + isAvailable(5), + isAccurate(6), + isMaster(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "the current status of this reference as an Integer value" + + -- 0: reference source not available + -- 1: not supported in this system + -- 2: nothing connected to this input* + -- 3: no signal detected* + -- 4: reference source has locked to the signal* + -- 5: reference is available + -- 6: reference is considered valid and accurate* + -- 7: reference is the current MRS master + -- NOTE: + -- States marked with * are not supported by all references + + ::= { mbgLtMrsRefNtp 6 } + +mbgLtMrsNtpCorr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Correction Value (Fixed Offset) of this reference in nanoseconds" + -- Example : "+100" + + ::= { mbgLtMrsRefNtp 7 } + +mbgLtMrsNtpOffsLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Offset Limit in nanoseconds, if exceeded this will trigger a notification" + -- Example : "100" + + ::= { mbgLtMrsRefNtp 8 } + + +mbgLtMrsNtpPrecision OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Precision Factor of this reference in nanoseconds" + -- Example : "100" + -- Note: Only positive values allowed + + ::= { mbgLtMrsRefNtp 9 } + +-- +-- Lantime SNMP trap definitions +-- + +mbgLtNotifications OBJECT IDENTIFIER ::= { mbgLantime 3 } +mbgLtTraps OBJECT IDENTIFIER ::= { mbgLtNotifications 0 } + + +mbgLtTrapNTPNotSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when NTP is not synchronised " + ::= { mbgLtTraps 1 } + +mbgLtTrapNTPStopped NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when NTP is stopped " + ::= { mbgLtTraps 2 } + +mbgLtTrapServerBoot NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when time server has finished boot sequence " + ::= { mbgLtTraps 3 } + +mbgLtTrapReceiverNotResponding NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when receiver is not responding " + ::= { mbgLtTraps 4 } + +mbgLtTrapReceiverNotSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when receiver is not synchronised " + ::= { mbgLtTraps 5 } + +mbgLtTrapAntennaFaulty NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when connection to antenna is broken " + ::= { mbgLtTraps 6 } + +mbgLtTrapAntennaReconnect NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when antenna has been reconnected " + ::= { mbgLtTraps 7 } + +mbgLtTrapConfigChanged NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when timeserver reloaded its configuration " + ::= { mbgLtTraps 8 } + +mbgLtTrapLeapSecondAnnounced NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a leap second has been announced " + ::= { mbgLtTraps 9 } + +mbgLtTrapSHSTimeLimitError NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when SHS timelimit exceeded " + ::= { mbgLtTraps 10 } + +mbgLtTrapSecondaryRecNotSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when secondary receiver in SHS system is not synchronised " + ::= { mbgLtTraps 11 } + +mbgLtTrapPowerSupplyFailure NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when one of the redundant power supplies fails" + ::= { mbgLtTraps 12 } + +mbgLtTrapAntennaShortCircuit NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a connected antenna fails due to a short circuit" + ::= { mbgLtTraps 13 } + +mbgLtTrapReceiverSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when receiver is synchronised " + ::= { mbgLtTraps 14 } + +mbgLtTrapNTPClientAlarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable. " + ::= { mbgLtTraps 15 } + +mbgLtTrapPowerSupplyUp NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a power supply returned to a healthy state. " + ::= { mbgLtTraps 16 } + +mbgLtTrapNetworkDown NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a monitored network port is down. " + ::= { mbgLtTraps 17 } + +mbgLtTrapNetworkUp NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a monitored network port is up. " + ::= { mbgLtTraps 18 } + +mbgLtTrapSecondaryRecNotResp NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when secondary receiver is not responding " + ::= { mbgLtTraps 19 } + + +mbgLtTrapXmrLimitExceeded NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a reference offset exceeds the configured limit" + ::= { mbgLtTraps 30 } + +mbgLtTrapXmrRefDisconnect NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a reference signal has been lost" + ::= { mbgLtTraps 31 } + + +mbgLtTrapXmrRefReconnect NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a reference signal recovered" + ::= { mbgLtTraps 32 } + +mbgLtTrapFdmError NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when the Fdm module generates an alarm " + ::= { mbgLtTraps 33 } + +mbgLtTrapSHSTimeLimitWarning NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when SHS warning limit exceeded " + ::= { mbgLtTraps 34 } + +mbgLtTrapSecondaryRecSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when secondary receiver is synchronised " + ::= { mbgLtTraps 35 } + +mbgLtTrapNTPSync NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when NTP is synchronised " + ::= { mbgLtTraps 36 } + +mbgLtTrapPtpPortDisconnected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when PTP network port got disconnected" + ::= { mbgLtTraps 37 } + +mbgLtTrapPtpPortConnected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when PTP network port got connected" + ::= { mbgLtTraps 38 } + +mbgLtTrapPtpStateChanged NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when PTP state changed (e.g. from 'passive' to 'master')" + ::= { mbgLtTraps 39 } + +mbgLtTrapPtpError NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when PTP raised an error" + ::= { mbgLtTraps 40 } + +mbgLtTrapNormalOperation NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when the system returned to a healthy state " + ::= { mbgLtTraps 77 } + +mbgLtTrapHeartbeat NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent periodically to indicate that time server is still alive " + ::= { mbgLtTraps 88 } + +mbgLtTrapTestNotification NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "trap to be sent when a test notification has been requested " + ::= { mbgLtTraps 99 } + +mbgLtTrapMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "used as a payload object for all traps, holds a clear text event message" + DEFVAL { "no event" } + ::= { mbgLtTraps 100 } + +-- +-- Meinberg Lantime CFG MIB objects for agent module +-- + + +mbgLtCfg OBJECT IDENTIFIER ::= { mbgLantime 4 } + +-- +-- Network parameters +-- + + +mbgLtCfgNetwork OBJECT IDENTIFIER ::= { mbgLtCfg 1 } + +mbgLtCfgHostname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hostname configured for this LANTIME" + ::= { mbgLtCfgNetwork 1 } + +mbgLtCfgDomainname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The domainname configured for this LANTIME" + ::= { mbgLtCfgNetwork 2 } + + +mbgLtCfgNameserver1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first nameserver used by this LANTIME" + ::= { mbgLtCfgNetwork 3 } + +mbgLtCfgNameserver2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second nameserver used this LANTIME" + ::= { mbgLtCfgNetwork 4 } + +mbgLtCfgSyslogserver1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first syslog server we are sending log entries to" + ::= { mbgLtCfgNetwork 5 } + +mbgLtCfgSyslogserver2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second syslog server we are sending log entries to" + ::= { mbgLtCfgNetwork 6 } + +mbgLtCfgTelnetAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is telnet administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 7 } + +mbgLtCfgFTPAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is FTP administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 8 } + +mbgLtCfgHTTPAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is web based administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 9 } + +mbgLtCfgHTTPSAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is secure web based administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 10 } + +mbgLtCfgSNMPAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is SNMP administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 11 } + +mbgLtCfgSambaAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is Samba administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 12 } + +mbgLtCfgIPv6Access OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 support enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 13 } + +mbgLtCfgSSHAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is SSH administration enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNetwork 14 } + + + + +-- +-- NTP parameters +-- + + +mbgLtCfgNTP OBJECT IDENTIFIER ::= { mbgLtCfg 2 } + + +mbgLtCfgNTPServer1 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 1 } +mbgLtCfgNTPServer2 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 2 } +mbgLtCfgNTPServer3 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 3 } +mbgLtCfgNTPServer4 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 4 } +mbgLtCfgNTPServer5 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 5 } +mbgLtCfgNTPServer6 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 6 } +mbgLtCfgNTPServer7 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 7 } + +mbgLtCfgNTPServer1IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer1 1 } + +mbgLtCfgNTPServer1Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer1 2 } + +mbgLtCfgNTPServer1Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer1 3 } + +mbgLtCfgNTPServer1Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer1 4 } + + + +mbgLtCfgNTPServer2IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer2 1 } + +mbgLtCfgNTPServer2Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer2 2 } + +mbgLtCfgNTPServer2Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer2 3 } + +mbgLtCfgNTPServer2Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer2 4 } + + + + +mbgLtCfgNTPServer3IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer3 1 } + +mbgLtCfgNTPServer3Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer3 2 } + +mbgLtCfgNTPServer3Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer3 3 } + +mbgLtCfgNTPServer3Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer3 4 } + + + + +mbgLtCfgNTPServer4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer4 1 } + +mbgLtCfgNTPServer4Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer4 2 } + +mbgLtCfgNTPServer4Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer4 3 } + +mbgLtCfgNTPServer4Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer4 4 } + + + +mbgLtCfgNTPServer5IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer5 1 } + +mbgLtCfgNTPServer5Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer5 2 } + +mbgLtCfgNTPServer5Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer5 3 } + +mbgLtCfgNTPServer5Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer5 4 } + + + + +mbgLtCfgNTPServer6IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer6 1 } + +mbgLtCfgNTPServer6Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer6 2 } + +mbgLtCfgNTPServer6Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer6 3 } + +mbgLtCfgNTPServer6Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer6 4 } + + + +mbgLtCfgNTPServer7IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address for external NTP server" + ::= { mbgLtCfgNTPServer7 1 } + +mbgLtCfgNTPServer7Key OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key for external NTP server" + ::= { mbgLtCfgNTPServer7 2 } + +mbgLtCfgNTPServer7Autokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer7 3 } + +mbgLtCfgNTPServer7Prefer OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the preferred flag enabled for the external NTP server" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTPServer7 4 } + + + + + +mbgLtCfgNTPStratumLocalClock OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The stratum value assigned to the local clock of the timeserver" + ::= { mbgLtCfgNTP 8 } + + +mbgLtCfgNTPTrustedKey OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The key used for the internal refclock of the timeserver" + ::= { mbgLtCfgNTP 9 } + +mbgLtCfgNTPBroadcastIP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "NTP broadcast IP address" + ::= { mbgLtCfgNTP 10 } + +mbgLtCfgNTPBroadcastKey OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Key used for NTP broadcasts" + ::= { mbgLtCfgNTP 11 } + + +mbgLtCfgNTPBroadcastAutokey OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is autokey generation used for NTP broadcasts" + ::= { mbgLtCfgNTP 12 } + + +mbgLtCfgNTPAutokeyFeature OBJECT-TYPE + + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the NTP autokey feature enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTP 13 } + + +mbgLtCfgNTPAtomPPS OBJECT-TYPE + + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is the NTP atom pps feature enabled" + --- "1 = true, 2 = false" + ::= { mbgLtCfgNTP 14 } + + + + +-- +-- EMail parameters +-- + + +mbgLtCfgEMail OBJECT IDENTIFIER ::= { mbgLtCfg 3 } + +mbgLtCfgEMailTo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EMail address to send alerts etc. to (receiving address)" + ::= { mbgLtCfgEMail 1 } + +mbgLtCfgEMailFrom OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EMail address to send alerts etc. from (sending address)" + ::= { mbgLtCfgEMail 2 } + +mbgLtCfgEMailSmarthost OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SMTP smarthost used to send mail" + ::= { mbgLtCfgEMail 3 } + + +-- +-- SNMP parameters +-- + + + +mbgLtCfgSNMP OBJECT IDENTIFIER ::= { mbgLtCfg 4 } + +mbgLtCfgSNMPTrapReceiver1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "First SNMP trap receiver host" + ::= { mbgLtCfgSNMP 1 } + +mbgLtCfgSNMPTrapReceiver2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Second SNMP trap receiver host" + ::= { mbgLtCfgSNMP 2 } + +mbgLtCfgSNMPTrapRec1Community OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "First SNMP trap receiver community" + ::= { mbgLtCfgSNMP 3 } + +mbgLtCfgSNMPTrapRec2Community OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Second SNMP trap receiver community" + ::= { mbgLtCfgSNMP 4 } + + +mbgLtCfgSNMPReadOnlyCommunity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP community string for read-only access" + ::= { mbgLtCfgSNMP 5 } + + +mbgLtCfgSNMPReadWriteCommunity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP community string for read-write access" + ::= { mbgLtCfgSNMP 6 } + + +mbgLtCfgSNMPContact OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP contact string for Lantime" + ::= { mbgLtCfgSNMP 7 } + + +mbgLtCfgSNMPLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNMP location string for Lantime" + ::= { mbgLtCfgSNMP 8 } + + +-- +-- Winpopup parameters +-- + +mbgLtCfgWinpopup OBJECT IDENTIFIER ::= { mbgLtCfg 5 } + +mbgLtCfgWMailAddress1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "First windows popup alert receiver" + ::= { mbgLtCfgWinpopup 1 } + +mbgLtCfgWMailAddress2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Second windows popup alert receiver" + ::= { mbgLtCfgWinpopup 2 } + + +-- +-- Wallmount display parameters +-- + + +mbgLtCfgWalldisplay OBJECT IDENTIFIER ::= { mbgLtCfg 6 } + +mbgLtCfgVP100Display1IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address of first VP100 wall display" + ::= { mbgLtCfgWalldisplay 1 } + +mbgLtCfgVP100Display1SN OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Serial number of first VP100 wall display" + ::= { mbgLtCfgWalldisplay 2 } + +mbgLtCfgVP100Display2IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP address of second VP100 wall display" + ::= { mbgLtCfgWalldisplay 3 } + +mbgLtCfgVP100Display2SN OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Serial number of second VP100 wall display" + ::= { mbgLtCfgWalldisplay 4 } + + + + +-- +-- Notify parameters +-- + + +mbgLtCfgNotify OBJECT IDENTIFIER ::= { mbgLtCfg 7 } + +mbgLtCfgNotifyNTPNotSync OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a NTP_not_sync event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 1 } + +mbgLtCfgNotifyNTPStopped OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a NTP_stopped event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 2 } + +mbgLtCfgNotifyServerBoot OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a server_boot event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 3 } + +mbgLtCfgNotifyRefclkNoResponse OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a refclock_not_responding event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 4 } + +mbgLtCfgNotifyRefclockNotSync OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a refclock_not_sync event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 5 } + +mbgLtCfgNotifyAntennaFaulty OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of an antenna_faulty event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 6 } + +mbgLtCfgNotifyAntennaReconnect OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of an antenna_reconnect event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 7 } + +mbgLtCfgNotifyConfigChanged OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a config_changed event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these" + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 8 } + +mbgLtCfgNotifySHSTimeLimitError OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a SHS_timelimiterror event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these." + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 9 } + + + +mbgLtCfgNotifyLeapSecond OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Which alerts are sent in case of a Leap_Second_Announced event" + --- possible strings: + --- "email (sending an e-mail)" + --- "wmail (sending a win popup message)" + --- "snmp (sending a SNMP trap)" + --- "disp (showing an alert on wall display)" + --- "or a comma separated combination of these." + --- "An empty string disables notification for this event." + --- "Example: wmail,email (sending a win popup and e-mail message)" + + ::= { mbgLtCfgNotify 10 } + + + + +-- +-- Ethernet parameters +-- + + +mbgLtCfgEthernet OBJECT IDENTIFIER ::= { mbgLtCfg 8 } + +mbgLtCfgEthernetIf0 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 0 } +mbgLtCfgEthernetIf1 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 1 } +mbgLtCfgEthernetIf2 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 2 } +mbgLtCfgEthernetIf3 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 3 } +mbgLtCfgEthernetIf4 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 4 } +mbgLtCfgEthernetIf5 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 5 } +mbgLtCfgEthernetIf6 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 6 } +mbgLtCfgEthernetIf7 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 7 } +mbgLtCfgEthernetIf8 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 8 } +mbgLtCfgEthernetIf9 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 9 } + + + + + +mbgLtCfgEthernetIf0IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 1 } + +mbgLtCfgEthernetIf0IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 2 } + +mbgLtCfgEthernetIf0IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 3 } + + +mbgLtCfgEthernetIf0DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf0 4 } + +mbgLtCfgEthernetIf0IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 5 } + +mbgLtCfgEthernetIf0IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 6 } + +mbgLtCfgEthernetIf0IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the first ethernet interface" + ::= { mbgLtCfgEthernetIf0 7 } + +mbgLtCfgEthernetIf0IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf0 8 } + +mbgLtCfgEthernetIf0NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf0 9 } + + +mbgLtCfgEthernetIf1IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 1 } + +mbgLtCfgEthernetIf1IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 2 } + +mbgLtCfgEthernetIf1IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 3 } + + +mbgLtCfgEthernetIf1DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf1 4 } + +mbgLtCfgEthernetIf1IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 5 } + +mbgLtCfgEthernetIf1IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 6 } + +mbgLtCfgEthernetIf1IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the second ethernet interface" + ::= { mbgLtCfgEthernetIf1 7 } + +mbgLtCfgEthernetIf1IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf1 8 } + +mbgLtCfgEthernetIf1NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf1 9 } + + +mbgLtCfgEthernetIf2IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 1 } + +mbgLtCfgEthernetIf2IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 2 } + +mbgLtCfgEthernetIf2IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 3 } + + +mbgLtCfgEthernetIf2DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf2 4 } + +mbgLtCfgEthernetIf2IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 5 } + +mbgLtCfgEthernetIf2IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 6 } + +mbgLtCfgEthernetIf2IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the third ethernet interface" + ::= { mbgLtCfgEthernetIf2 7 } + +mbgLtCfgEthernetIf2IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf2 8 } + +mbgLtCfgEthernetIf2NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf2 9 } + + +mbgLtCfgEthernetIf3IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 1 } + +mbgLtCfgEthernetIf3IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 2 } + +mbgLtCfgEthernetIf3IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 3 } + + +mbgLtCfgEthernetIf3DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf3 4 } + +mbgLtCfgEthernetIf3IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 5 } + +mbgLtCfgEthernetIf3IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 6 } + +mbgLtCfgEthernetIf3IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the fourth ethernet interface" + ::= { mbgLtCfgEthernetIf3 7 } + +mbgLtCfgEthernetIf3IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf3 8 } + +mbgLtCfgEthernetIf3NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf3 9 } + + +mbgLtCfgEthernetIf4IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 1 } + +mbgLtCfgEthernetIf4IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 2 } + +mbgLtCfgEthernetIf4IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 3 } + + +mbgLtCfgEthernetIf4DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf4 4 } + +mbgLtCfgEthernetIf4IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 5 } + +mbgLtCfgEthernetIf4IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 6 } + +mbgLtCfgEthernetIf4IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the fifth ethernet interface" + ::= { mbgLtCfgEthernetIf4 7 } + +mbgLtCfgEthernetIf4IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf4 8 } + +mbgLtCfgEthernetIf4NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf4 9 } + + +mbgLtCfgEthernetIf5IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 1 } + +mbgLtCfgEthernetIf5IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 2 } + +mbgLtCfgEthernetIf5IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 3 } + + +mbgLtCfgEthernetIf5DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf5 4 } + +mbgLtCfgEthernetIf5IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 5 } + +mbgLtCfgEthernetIf5IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 6 } + +mbgLtCfgEthernetIf5IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the sixth ethernet interface" + ::= { mbgLtCfgEthernetIf5 7 } + +mbgLtCfgEthernetIf5IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf5 8 } + +mbgLtCfgEthernetIf5NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf5 9 } + + +mbgLtCfgEthernetIf6IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 1 } + +mbgLtCfgEthernetIf6IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 2 } + +mbgLtCfgEthernetIf6IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 3 } + + +mbgLtCfgEthernetIf6DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf6 4 } + +mbgLtCfgEthernetIf6IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 5 } + +mbgLtCfgEthernetIf6IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 6 } + +mbgLtCfgEthernetIf6IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the seventh ethernet interface" + ::= { mbgLtCfgEthernetIf6 7 } + +mbgLtCfgEthernetIf6IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf6 8 } + +mbgLtCfgEthernetIf6NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf6 9 } + + +mbgLtCfgEthernetIf7IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 1 } + +mbgLtCfgEthernetIf7IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 2 } + +mbgLtCfgEthernetIf7IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 3 } + + +mbgLtCfgEthernetIf7DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf7 4 } + +mbgLtCfgEthernetIf7IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 5 } + +mbgLtCfgEthernetIf7IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 6 } + +mbgLtCfgEthernetIf7IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the eighth ethernet interface" + ::= { mbgLtCfgEthernetIf7 7 } + +mbgLtCfgEthernetIf7IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf7 8 } + +mbgLtCfgEthernetIf7NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf7 9 } + + +mbgLtCfgEthernetIf8IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 1 } + +mbgLtCfgEthernetIf8IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 2 } + +mbgLtCfgEthernetIf8IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 3 } + + +mbgLtCfgEthernetIf8DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf8 4 } + +mbgLtCfgEthernetIf8IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 5 } + +mbgLtCfgEthernetIf8IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 6 } + +mbgLtCfgEthernetIf8IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the nineth ethernet interface" + ::= { mbgLtCfgEthernetIf8 7 } + +mbgLtCfgEthernetIf8IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf8 8 } + +mbgLtCfgEthernetIf8NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf8 9 } + + +mbgLtCfgEthernetIf9IPv4IP OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 1 } + +mbgLtCfgEthernetIf9IPv4Netmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 netmask of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 2 } + +mbgLtCfgEthernetIf9IPv4Gateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 gateway address of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 3 } + + +mbgLtCfgEthernetIf9DHCPClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is DHCP used to get IP parameters for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf9 4 } + +mbgLtCfgEthernetIf9IPv6IP1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The first IPv6 address of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 5 } + +mbgLtCfgEthernetIf9IPv6IP2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The second IPv6 address of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 6 } + +mbgLtCfgEthernetIf9IPv6IP3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The third IPv6 address of the tenth ethernet interface" + ::= { mbgLtCfgEthernetIf9 7 } + +mbgLtCfgEthernetIf9IPv6Autoconf OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is IPv6 Autoconf used for this interface" + --- "1 = true, 2 = false" + ::= { mbgLtCfgEthernetIf9 8 } + +mbgLtCfgEthernetIf9NetLinkMode OBJECT-TYPE + SYNTAX INTEGER { + autosensing(0), + link10half(1), + link10full(2), + link100half(3), + link100full(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Link mode for this interface" + + ::= { mbgLtCfgEthernetIf9 9 } + + +-- +-- SHS specific parameters +-- + + +mbgLtCfgSHS OBJECT IDENTIFIER ::= { mbgLtCfg 9 } + + +mbgLtCfgSHSCritLimit OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Max. number of milliseconds the two SHS references can differ before a SHS Critical Timelimit error is issued" + ::= { mbgLtCfgSHS 1 } + +mbgLtCfgSHSWarnLimit OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Max. number of milliseconds the two SHS references can differ before a SHS Warning Timelimit error is issued" + ::= { mbgLtCfgSHS 2 } + + +-- +-- MRS specific parameters +-- + +mbgLtCfgMRS OBJECT IDENTIFIER ::= { mbgLtCfg 10 } + +mbgLtCfgMRSRefPriority OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Priority of MRS Reference Sources, as a comma-separated list" + --- Example: "gps,irig,ntp" + --- Possible reference sources are: + ::= { mbgLtCfgMRS 1 } + + + +-- +-- Lantime SNMP commands +-- + +mbgLtCmd OBJECT IDENTIFIER ::= { mbgLantime 5 } + +mbgLtCmdExecute OBJECT-TYPE + SYNTAX INTEGER { + ready(0), + doReboot(1), + doFirmwareUpdate (2), + doReloadConfig (3), + doGenerateSSHKey (4), + doGenerateHTTPSKey (5), + doResetFactoryDefaults (6), + doGenerateNewNTPAutokeyCert (7), + doSendTestNotification (8), + doResetSHSTimeLimitError (9) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Send a command to the timeserver to be executed" + + ::={ mbgLtCmd 1 } + +mbgLtCmdSetRefTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the time of the reference clock and the LANTIME itself" + -- The new time has to be specified in UTC time and + -- can be either written as a valid ISO8601 date and time string + -- e.g. 2006-08-23 16:05:30 (=08/23/2006, 4:05:30pm) + -- or a simple number representing the number of seconds + -- since 01/01/1970 + + ::={ mbgLtCmd 2 } + + + +mbgLtPtp OBJECT IDENTIFIER ::= { mbgLantime 10 } + + +mbgLtPtpMode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display current PTPv2 modus as string" + ::= { mbgLtPtp 1 } + + +mbgLtPtpModeVal OBJECT-TYPE + SYNTAX INTEGER { + stopped (0), + master (1), + slave (2), + ordinary (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display current PTPv2 modus as integer" + ::= { mbgLtPtp 2 } + + +mbgLtPtpPortState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current PTPv2 port state as string" + ::= { mbgLtPtp 3 } + + +mbgLtPtpPortStateVal OBJECT-TYPE + SYNTAX INTEGER { + uncalibrated (0), + initializing (1), + listening (2), + master (3), + slave (4), + unicastmaster (5), + unicastslave (6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current PTPv2 port state as integer" + ::= { mbgLtPtp 4 } + + +mbgLtPtpOffsetFromGM OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current PTPv2 offset from grandmaster as string" + ::= { mbgLtPtp 5 } + + +mbgLtPtpOffsetFromGMVal OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + UNITS "ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current PTPv2 offset from grandmaster in nanoseconds" + ::= { mbgLtPtp 6 } + + +mbgLtPtpDelay OBJECT-TYPE + SYNTAX DisplayString + UNITS "ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the current network delay in nanoseconds as string" + ::= { mbgLtPtp 7 } + + +mbgLtPtpDelayVal OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + UNITS "ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the current network delay in nanoseconds" + ::= { mbgLtPtp 8 } + + + + +-- +-- FDM Powerline Frequency Deviation Monitor Module +-- + +mbgLtFdm OBJECT IDENTIFIER ::= { mbgLantime 11 } + +mbgLtFdmPlFreq OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the current powerline frequency in mHz as an Integer32 value" + ::= { mbgLtFdm 1 } + +mbgLtFdmFreqDev OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the current frequency deviation in mHz as an Integer32 value" + ::= { mbgLtFdm 2 } + +mbgLtFdmNomFreq OBJECT-TYPE + SYNTAX Integer32 (-2147483648..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "shows the nominal frequency in mHz as an Integer32 value" + -- can be 50000 (50Hz) or 60000 (60Hz) + ::= { mbgLtFdm 3 } + + + + + +mbgLtConformance OBJECT IDENTIFIER ::= { mbgLantime 90 } +mbgLtCompliances OBJECT IDENTIFIER ::= { mbgLtConformance 1 } +mbgLtGroups OBJECT IDENTIFIER ::= { mbgLtConformance 2 } + +mbgLtCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for SNMP entities which implement version 2 + of the LANTIME MIB" + MODULE -- this module + MANDATORY-GROUPS { + mbgLtObjectsGroup, + mbgLtTrapsGroup + } + ::= { mbgLtCompliances 1 } + + +mbgLtObjectsGroup OBJECT-GROUP + OBJECTS { + mbgLtFirmwareVersion, + mbgLtFirmwareVersionVal, + mbgLtNtpCurrentState, + mbgLtNtpCurrentStateVal, + mbgLtNtpStratum, + mbgLtNtpActiveRefclockId, + mbgLtNtpActiveRefclockName, + mbgLtNtpActiveRefclockOffset, + mbgLtNtpActiveRefclockOffsetVal, + mbgLtNtpNumberOfRefclocks, + mbgLtNtpAuthKeyId, + mbgLtNtpVersion, + mbgLtRefClockType, + mbgLtRefClockTypeVal, + mbgLtRefClockMode, + mbgLtRefClockModeVal, + mbgLtRefGpsState, + mbgLtRefGpsStateVal, + mbgLtRefGpsPosition, + mbgLtRefGpsSatellites, + mbgLtRefGpsSatellitesGood, + mbgLtRefGpsSatellitesInView, + mbgLtRefPzfState, + mbgLtRefPzfStateVal, + mbgLtRefPzfKorrelation, + mbgLtRefPzfField, + mbgLtRefGpsMode, + mbgLtRefGpsModeVal, + mbgLtRefIrigMode, + mbgLtRefIrigModeVal, + mbgLtRefPzfMode, + mbgLtRefPzfModeVal, + mbgLtRefIrigState, + mbgLtRefIrigStateVal, + mbgLtRefSHSMode, + mbgLtRefSHSModeVal, + mbgLtRefSHSTimeDiff, + mbgLtRefDctState, + mbgLtRefDctStateVal, + mbgLtRefDctField, + mbgLtRefDctMode, + mbgLtRefDctModeVal, + mbgLtRefGpsLeapSecond, + mbgLtRefGpsLeapCorrection, + mbgLtRefMrsRef, + mbgLtRefMrsRefVal, + mbgLtRefMrsRefList, + mbgLtRefMrsPrioList, + mbgLtMrsGpsOffs, + mbgLtMrsGpsOffsVal, + mbgLtMrsGpsOffsBase, + mbgLtMrsGpsPrio, + mbgLtMrsGpsState, + mbgLtMrsGpsStateVal, + mbgLtMrsGpsPrecision, + mbgLtMrsIrigOffs, + mbgLtMrsIrigOffsVal, + mbgLtMrsIrigOffsBase, + mbgLtMrsIrigPrio, + mbgLtMrsIrigState, + mbgLtMrsIrigStateVal, + mbgLtMrsIrigCorr, + mbgLtMrsIrigOffsLimit, + mbgLtMrsIrigPrecision, + mbgLtMrsPpsOffs, + mbgLtMrsPpsOffsVal, + mbgLtMrsPpsOffsBase, + mbgLtMrsPpsPrio, + mbgLtMrsPpsState, + mbgLtMrsPpsStateVal, + mbgLtMrsPpsCorr, + mbgLtMrsPpsOffsLimit, + mbgLtMrsPpsPrecision, + mbgLtMrsFreqOffs, + mbgLtMrsFreqOffsVal, + mbgLtMrsFreqOffsBase, + mbgLtMrsFreqPrio, + mbgLtMrsFreqState, + mbgLtMrsFreqStateVal, + mbgLtMrsFreqCorr, + mbgLtMrsFreqOffsLimit, + mbgLtMrsFreqPrecision, + mbgLtMrsPtpOffs, + mbgLtMrsPtpOffsVal, + mbgLtMrsPtpOffsBase, + mbgLtMrsPtpPrio, + mbgLtMrsPtpState, + mbgLtMrsPtpStateVal, + mbgLtMrsPtpCorr, + mbgLtMrsPtpOffsLimit, + mbgLtMrsPtpPrecision, + mbgLtMrsNtpOffs, + mbgLtMrsNtpOffsVal, + mbgLtMrsNtpOffsBase, + mbgLtMrsNtpPrio, + mbgLtMrsNtpState, + mbgLtMrsNtpStateVal, + mbgLtMrsNtpCorr, + mbgLtMrsNtpOffsLimit, + mbgLtMrsNtpPrecision, + mbgLtTrapMessage, + mbgLtCfgHostname, + mbgLtCfgDomainname, + mbgLtCfgNameserver1, + mbgLtCfgNameserver2, + mbgLtCfgSyslogserver1, + mbgLtCfgSyslogserver2, + mbgLtCfgTelnetAccess, + mbgLtCfgFTPAccess, + mbgLtCfgHTTPAccess, + mbgLtCfgHTTPSAccess, + mbgLtCfgSNMPAccess, + mbgLtCfgSambaAccess, + mbgLtCfgIPv6Access, + mbgLtCfgSSHAccess, + mbgLtCfgNTPServer1IP, + mbgLtCfgNTPServer1Key, + mbgLtCfgNTPServer1Autokey, + mbgLtCfgNTPServer1Prefer, + mbgLtCfgNTPServer2IP, + mbgLtCfgNTPServer2Key, + mbgLtCfgNTPServer2Autokey, + mbgLtCfgNTPServer2Prefer, + mbgLtCfgNTPServer3IP, + mbgLtCfgNTPServer3Key, + mbgLtCfgNTPServer3Autokey, + mbgLtCfgNTPServer3Prefer, + mbgLtCfgNTPServer4IP, + mbgLtCfgNTPServer4Key, + mbgLtCfgNTPServer4Autokey, + mbgLtCfgNTPServer4Prefer, + mbgLtCfgNTPServer5IP, + mbgLtCfgNTPServer5Key, + mbgLtCfgNTPServer5Autokey, + mbgLtCfgNTPServer5Prefer, + mbgLtCfgNTPServer6IP, + mbgLtCfgNTPServer6Key, + mbgLtCfgNTPServer6Autokey, + mbgLtCfgNTPServer6Prefer, + mbgLtCfgNTPServer7IP, + mbgLtCfgNTPServer7Key, + mbgLtCfgNTPServer7Autokey, + mbgLtCfgNTPServer7Prefer, + mbgLtCfgNTPStratumLocalClock, + mbgLtCfgNTPTrustedKey, + mbgLtCfgNTPBroadcastIP, + mbgLtCfgNTPBroadcastKey, + mbgLtCfgNTPBroadcastAutokey, + mbgLtCfgNTPAutokeyFeature, + mbgLtCfgNTPAtomPPS, + mbgLtCfgEMailTo, + mbgLtCfgEMailFrom, + mbgLtCfgEMailSmarthost, + mbgLtCfgSNMPTrapReceiver1, + mbgLtCfgSNMPTrapReceiver2, + mbgLtCfgSNMPTrapRec1Community, + mbgLtCfgSNMPTrapRec2Community, + mbgLtCfgSNMPReadOnlyCommunity, + mbgLtCfgSNMPReadWriteCommunity, + mbgLtCfgSNMPContact, + mbgLtCfgSNMPLocation, + mbgLtCfgWMailAddress1, + mbgLtCfgWMailAddress2, + mbgLtCfgVP100Display1IP, + mbgLtCfgVP100Display1SN, + mbgLtCfgVP100Display2IP, + mbgLtCfgVP100Display2SN, + mbgLtCfgNotifyNTPNotSync, + mbgLtCfgNotifyNTPStopped, + mbgLtCfgNotifyServerBoot, + mbgLtCfgNotifyRefclkNoResponse, + mbgLtCfgNotifyRefclockNotSync, + mbgLtCfgNotifyAntennaFaulty, + mbgLtCfgNotifyAntennaReconnect, + mbgLtCfgNotifyConfigChanged, + mbgLtCfgNotifySHSTimeLimitError, + mbgLtCfgNotifyLeapSecond, + mbgLtCfgEthernetIf0IPv4IP, + mbgLtCfgEthernetIf0IPv4Netmask, + mbgLtCfgEthernetIf0IPv4Gateway, + mbgLtCfgEthernetIf0DHCPClient, + mbgLtCfgEthernetIf0IPv6IP1, + mbgLtCfgEthernetIf0IPv6IP2, + mbgLtCfgEthernetIf0IPv6IP3, + mbgLtCfgEthernetIf0IPv6Autoconf, + + mbgLtCfgEthernetIf0NetLinkMode, + mbgLtCfgEthernetIf1IPv4IP, + mbgLtCfgEthernetIf1IPv4Netmask, + mbgLtCfgEthernetIf1IPv4Gateway, + mbgLtCfgEthernetIf1DHCPClient, + mbgLtCfgEthernetIf1IPv6IP1, + mbgLtCfgEthernetIf1IPv6IP2, + mbgLtCfgEthernetIf1IPv6IP3, + mbgLtCfgEthernetIf1IPv6Autoconf, + mbgLtCfgEthernetIf1NetLinkMode, + mbgLtCfgEthernetIf2IPv4IP, + mbgLtCfgEthernetIf2IPv4Netmask, + mbgLtCfgEthernetIf2IPv4Gateway, + mbgLtCfgEthernetIf2DHCPClient, + mbgLtCfgEthernetIf2IPv6IP1, + mbgLtCfgEthernetIf2IPv6IP2, + mbgLtCfgEthernetIf2IPv6IP3, + mbgLtCfgEthernetIf2IPv6Autoconf, + mbgLtCfgEthernetIf2NetLinkMode, + mbgLtCfgEthernetIf3IPv4IP, + mbgLtCfgEthernetIf3IPv4Netmask, + mbgLtCfgEthernetIf3IPv4Gateway, + mbgLtCfgEthernetIf3DHCPClient, + mbgLtCfgEthernetIf3IPv6IP1, + mbgLtCfgEthernetIf3IPv6IP2, + mbgLtCfgEthernetIf3IPv6IP3, + mbgLtCfgEthernetIf3IPv6Autoconf, + mbgLtCfgEthernetIf3NetLinkMode, + mbgLtCfgEthernetIf4IPv4IP, + mbgLtCfgEthernetIf4IPv4Netmask, + mbgLtCfgEthernetIf4IPv4Gateway, + mbgLtCfgEthernetIf4DHCPClient, + mbgLtCfgEthernetIf4IPv6IP1, + mbgLtCfgEthernetIf4IPv6IP2, + mbgLtCfgEthernetIf4IPv6IP3, + mbgLtCfgEthernetIf4IPv6Autoconf, + mbgLtCfgEthernetIf4NetLinkMode, + mbgLtCfgEthernetIf5IPv4IP, + mbgLtCfgEthernetIf5IPv4Netmask, + mbgLtCfgEthernetIf5IPv4Gateway, + mbgLtCfgEthernetIf5DHCPClient, + mbgLtCfgEthernetIf5IPv6IP1, + mbgLtCfgEthernetIf5IPv6IP2, + mbgLtCfgEthernetIf5IPv6IP3, + mbgLtCfgEthernetIf5IPv6Autoconf, + mbgLtCfgEthernetIf5NetLinkMode, + mbgLtCfgEthernetIf6IPv4IP, + mbgLtCfgEthernetIf6IPv4Netmask, + mbgLtCfgEthernetIf6IPv4Gateway, + mbgLtCfgEthernetIf6DHCPClient, + mbgLtCfgEthernetIf6IPv6IP1, + mbgLtCfgEthernetIf6IPv6IP2, + mbgLtCfgEthernetIf6IPv6IP3, + mbgLtCfgEthernetIf6IPv6Autoconf, + mbgLtCfgEthernetIf6NetLinkMode, + mbgLtCfgEthernetIf7IPv4IP, + mbgLtCfgEthernetIf7IPv4Netmask, + mbgLtCfgEthernetIf7IPv4Gateway, + mbgLtCfgEthernetIf7DHCPClient, + mbgLtCfgEthernetIf7IPv6IP1, + mbgLtCfgEthernetIf7IPv6IP2, + mbgLtCfgEthernetIf7IPv6IP3, + mbgLtCfgEthernetIf7IPv6Autoconf, + mbgLtCfgEthernetIf7NetLinkMode, + mbgLtCfgEthernetIf8IPv4IP, + mbgLtCfgEthernetIf8IPv4Netmask, + mbgLtCfgEthernetIf8IPv4Gateway, + mbgLtCfgEthernetIf8DHCPClient, + mbgLtCfgEthernetIf8IPv6IP1, + mbgLtCfgEthernetIf8IPv6IP2, + mbgLtCfgEthernetIf8IPv6IP3, + mbgLtCfgEthernetIf8IPv6Autoconf, + mbgLtCfgEthernetIf8NetLinkMode, + mbgLtCfgEthernetIf9IPv4IP, + mbgLtCfgEthernetIf9IPv4Netmask, + mbgLtCfgEthernetIf9IPv4Gateway, + mbgLtCfgEthernetIf9DHCPClient, + mbgLtCfgEthernetIf9IPv6IP1, + mbgLtCfgEthernetIf9IPv6IP2, + mbgLtCfgEthernetIf9IPv6IP3, + mbgLtCfgEthernetIf9IPv6Autoconf, + mbgLtCfgEthernetIf9NetLinkMode, + mbgLtCfgSHSCritLimit, + mbgLtCfgSHSWarnLimit, + mbgLtCfgMRSRefPriority, + mbgLtCmdExecute, + mbgLtCmdSetRefTime, + mbgLtFdmPlFreq, + mbgLtFdmFreqDev, + mbgLtFdmNomFreq, + mbgLtPtpMode, + mbgLtPtpModeVal, + mbgLtPtpPortState, + mbgLtPtpPortStateVal, + mbgLtPtpOffsetFromGM, + mbgLtPtpOffsetFromGMVal, + mbgLtPtpDelay, + mbgLtPtpDelayVal + } + STATUS current + DESCRIPTION + "The collection of objects for the LANTIME MIB" + ::= { mbgLtGroups 1 } + +mbgLtTrapsGroup NOTIFICATION-GROUP + NOTIFICATIONS { + mbgLtTrapNTPNotSync, + mbgLtTrapNTPStopped, + mbgLtTrapServerBoot, + mbgLtTrapReceiverNotResponding, + mbgLtTrapReceiverNotSync, + mbgLtTrapAntennaFaulty, + mbgLtTrapAntennaReconnect, + mbgLtTrapConfigChanged, + mbgLtTrapLeapSecondAnnounced, + mbgLtTrapSHSTimeLimitError, + mbgLtTrapSecondaryRecNotSync, + mbgLtTrapPowerSupplyFailure, + mbgLtTrapAntennaShortCircuit, + mbgLtTrapReceiverSync, + mbgLtTrapNTPClientAlarm, + mbgLtTrapPowerSupplyUp, + mbgLtTrapNetworkDown, + mbgLtTrapNetworkUp, + mbgLtTrapSecondaryRecNotResp, + mbgLtTrapXmrLimitExceeded, + mbgLtTrapXmrRefDisconnect, + mbgLtTrapXmrRefReconnect, + mbgLtTrapFdmError, + mbgLtTrapSHSTimeLimitWarning, + mbgLtTrapSecondaryRecSync, + mbgLtTrapNTPSync, + mbgLtTrapNormalOperation, + mbgLtTrapHeartbeat, + mbgLtTrapTestNotification, + mbgLtTrapPtpPortDisconnected, + mbgLtTrapPtpPortConnected, + mbgLtTrapPtpStateChanged, + mbgLtTrapPtpError + } + STATUS current + DESCRIPTION + "The collection of traps for the LANTIME MIB" + ::= { mbgLtGroups 2 } + +END |