summaryrefslogtreecommitdiff
path: root/MIBS/linksys/LINKSYS-Physicaldescription-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/linksys/LINKSYS-Physicaldescription-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/linksys/LINKSYS-Physicaldescription-MIB')
-rw-r--r--MIBS/linksys/LINKSYS-Physicaldescription-MIB1153
1 files changed, 1153 insertions, 0 deletions
diff --git a/MIBS/linksys/LINKSYS-Physicaldescription-MIB b/MIBS/linksys/LINKSYS-Physicaldescription-MIB
new file mode 100644
index 0000000..354d643
--- /dev/null
+++ b/MIBS/linksys/LINKSYS-Physicaldescription-MIB
@@ -0,0 +1,1153 @@
+LINKSYS-Physicaldescription-MIB DEFINITIONS ::= BEGIN
+
+-- Version: 7.46
+-- Date: 15-Jan-2007
+--
+-- 30-Jan-2004 Add rlPhdUnitGenParamTable
+-- 30-Jan-2004 Add rlPhdUnitEnvParamTable
+-- 24-Feb-2004 Add rlPhdStackOrderTopUnit
+-- 24-Feb-2004 Add rlPhdStackOrderBottomUnit
+-- 24-Feb-2004 Add rlPhdStackOrderPermutation
+-- 21-Apr-2005 Add rlPhdPortsTable switch description between:
+-- rlPhdPortsModuleNumber && rlPhdPortsStackUnit due to EWS need
+-- 27-Apr-2005 Add rlStackLinkChange trap.
+-- 16-May-2005 Add rlPhdNumberOfPoeUnits
+-- 02-Jun-2005 Add field to rlPhDUnitEnvParamTable: rlPhdUnitEnvParamUpTime
+-- 25-Jul-2005 Add rlPhdPhyLedTimeout and rlPhdPhyLedStackUnit
+-- 03-Aug-2005 Remove boundary for unit number field, checked by box
+-- this is done coz different products use different stack size
+-- 05-Sep-2005 Add rlCascadeTable
+-- 31-Oct-2005 Add rlCascadeAfterResetTable
+-- 14-Nov-2005 Change rlPhdUnitGenParamSerialNum to read-write
+-- 16-May-2006 Add field rlCascadeUnitId to rlCascadeEntry
+-- 14-Jan-2007 rlPhdModuleType was moved to a separated text file
+-- 15-Jan-2007 Devided file appolo.txt to a few files
+-- Renamed file appolo.txt to ralan-mib.mib
+-- 23-Jul-2012 IdanS: Add rlPhdUnitGenParamRegistrationDone and rlPhdUnitGenParamRegistrationSuppressed to RlPhdUnitGenParamEntry
+-- 09-Oct-2012 yahal: Add rlPhdUnitEnvParamMonitorAutoRecoveryEnable & rlPhdUnitEnvParamMonitorTemperatureStatus & rlPhdUnitEnvParamMonitorTemperatureStatus
+
+IMPORTS
+ OBJECT-TYPE, MODULE-IDENTITY, TimeTicks,
+ NOTIFICATION-TYPE FROM SNMPv2-SMI
+ DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC
+ JackType FROM MAU-MIB
+ rnd, rndNotifications FROM LINKSYS-MIB
+ RlEnvMonState FROM LINKSYS-HWENVIROMENT
+ EntitySensorStatus, EntitySensorValue FROM ENTITY-SENSOR-MIB
+ InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB
+ rndErrorDesc, rndErrorSeverity FROM LINKSYS-DEVICEPARAMS-MIB;
+
+rlPhysicalDescription MODULE-IDENTITY
+ LAST-UPDATED "200602120000Z"
+ ORGANIZATION "Linksys LLC."
+ CONTACT-INFO
+ "www.linksys.com/business/support"
+ DESCRIPTION
+ "The private MIB module definition for physical
+ device configuration."
+ REVISION "200602120000Z"
+ DESCRIPTION
+ "Removed TRAP-TYPE from IMPORTS."
+ REVISION "200310180000Z"
+ DESCRIPTION
+ "Initial version of this MIB."
+ ::= { rnd 53 }
+
+rlPhdMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MIB's version, the current version is 3.
+ 1: original version
+ 2: a. new tables
+ rlPhdModuleHotSwapTable
+ rlPhdStackOrderTable
+ b. new scalars
+ rlPhdStackReorder
+ rlPhdNumberOfUnits
+ rlPhdMaxNumberOfUnits
+ 3: a. new field rlPhdModuleRole of rlPhdModuleTable
+ b. new scalars
+ rlPhdForceMasterUnit
+ 4: a. new fields rlPhdModuleConnect1 and rlPhdModuleConnect2
+ of rlPhdModuleTable.
+ 5: a. Prefix rlPhD were replaced by prefix rlPhd
+ b. fields rlPhdModuleConnect1 and rlPhdModuleConnect2 are
+ moved from rlPhdModuleTable to rlPhdStackTable.
+ c. new fiels rlPhdStackSofrwareVer, rlPhdStackProductID and
+ rlPhdStackMacAddr of rlPhdStackTable.
+ d. new scalars
+ rlPhdStackReloadUnit
+ e. new scalars
+ rlPhdStackOrderTopUnit
+ rlPhdStackOrderBottomUnit
+ rlPhdStackOrderPermutation"
+ ::= { rlPhysicalDescription 1 }
+
+rlPhdModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each module (board) there is an entry describing it in this
+ module"
+ ::= { rlPhysicalDescription 2 }
+
+rlPhdModuleEntry OBJECT-TYPE
+ SYNTAX RlPhdModuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a module (board)"
+ INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex}
+ ::= { rlPhdModuleTable 1 }
+
+RlPhdModuleEntry ::= SEQUENCE {
+ rlPhdModuleStackUnit INTEGER,
+ rlPhdModuleIndex INTEGER,
+ rlPhdModuleType INTEGER,
+ rlPhdModuleStartingPort INTEGER,
+ rlPhdModuleNumberOfPorts INTEGER,
+ rlPhdModuleRow INTEGER,
+ rlPhdModuleColumn INTEGER,
+ rlPhdModuleRole INTEGER
+}
+
+rlPhdModuleStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the stack unit"
+ ::= { rlPhdModuleEntry 1 }
+
+rlPhdModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the module in its stack unit"
+ ::= { rlPhdModuleEntry 2 }
+
+rlPhdModuleType OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The index for each module type"
+ ::= { rlPhdModuleEntry 3 }
+
+rlPhdModuleStartingPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimal number of the port residing on this module."
+ ::= { rlPhdModuleEntry 4 }
+
+rlPhdModuleNumberOfPorts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of ports residing on this module."
+ ::= { rlPhdModuleEntry 5}
+
+rlPhdModuleRow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On which row (the uppermost being numbered 1 and the highest row
+ number asigned to the lowest row) this module resides within the
+ chassis of its stack unit."
+ ::= { rlPhdModuleEntry 6 }
+
+rlPhdModuleColumn OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On which column (the leftmost being numbered 1 and the highest column
+ number asigned to the rightmost column) this module resides within the
+ chassis of its stack unit."
+ ::= { rlPhdModuleEntry 7 }
+
+rlPhdModuleRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ standalone(1),
+ master(2),
+ backup(3),
+ slave(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The module role in the stack."
+ DEFVAL { standalone }
+ ::= { rlPhdModuleEntry 8 }
+
+rlPhdPortsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdPortsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Lists the physical or physical-related attributes of ports"
+ ::= { rlPhysicalDescription 3 }
+
+rlPhdPortsEntry OBJECT-TYPE
+ SYNTAX RlPhdPortsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each port, a entry describing attributes which are either
+ physical or are derived from the features of the device hardware"
+ INDEX { rlPhdPortsIfIndex }
+ ::= { rlPhdPortsTable 1 }
+
+RlPhdPortsEntry ::= SEQUENCE {
+ rlPhdPortsIfIndex INTEGER,
+ rlPhdPortsIfIndexName DisplayString(SIZE(1..20)),
+ rlPhdPortsMediaType INTEGER,
+ rlPhdPortsStackUnit INTEGER,
+ rlPhdPortsModuleNumber INTEGER,
+ rlPhdPortsRow INTEGER,
+ rlPhdPortsColumn INTEGER,
+ rlPhdConnectorType JackType,
+ rlPhdPortHaul INTEGER
+
+ }
+
+rlPhdPortsIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The L2 interface number associated with this port."
+ ::= { rlPhdPortsEntry 1 }
+
+rlPhdPortsIfIndexName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(1..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The L2 interface number associated with this port, in string format
+ based on the overall hardware architecture of the device (i.e., for
+ monolithic devices just numbers, devices composed of modules (boards,
+ cards) or stackable devices composed of monolithic units in form
+ <module /stack unit number> - <port number on current module /stack
+ unit number>, stackable devices in which each unit is composed of
+ modules
+ <stack unit number> - <module number> - <port number>"
+ ::= { rlPhdPortsEntry 2 }
+
+rlPhdPortsMediaType OBJECT-TYPE
+ SYNTAX INTEGER {copper(1), optic-fiber(2), combo(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The media type of this port."
+ ::= { rlPhdPortsEntry 3 }
+
+rlPhdPortsStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the slot to which this port belongs."
+ ::= { rlPhdPortsEntry 4 }
+
+rlPhdPortsModuleNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the stack unit to which this port resides in."
+ ::= { rlPhdPortsEntry 5 }
+
+rlPhdPortsRow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On which row (the uppermost being numbered 1 and the highest row
+ number asigned to the lowest row) this port resides within its
+ module."
+ ::= { rlPhdPortsEntry 6 }
+
+rlPhdPortsColumn OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On which column (the leftmost being numbered 1 and the highest column
+ number asigned to the rightmost column) this this port resides within its
+ module."
+ ::= { rlPhdPortsEntry 7 }
+
+rlPhdConnectorType OBJECT-TYPE
+ SYNTAX JackType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of connector."
+ ::= { rlPhdPortsEntry 8 }
+
+ rlPhdPortHaul OBJECT-TYPE
+ SYNTAX INTEGER {
+ not-relevant(1),
+ short(2),
+ long(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Distance supported by this port."
+ ::= { rlPhdPortsEntry 9 }
+
+rlPhdStackTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdStackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each stack unit there is an entry describing it in this table"
+ ::= { rlPhysicalDescription 4 }
+
+rlPhdStackEntry OBJECT-TYPE
+ SYNTAX RlPhdStackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a stack unit"
+ INDEX { rlPhdStackUnit }
+ ::= { rlPhdStackTable 1 }
+
+RlPhdStackEntry ::= SEQUENCE {
+ rlPhdStackUnit INTEGER,
+ rlPhdStackType INTEGER,
+ rlPhdStackConnect1 INTEGER,
+ rlPhdStackConnect2 INTEGER,
+ rlPhdStackSofrwareVer DisplayString,
+ rlPhdStackProductID DisplayString,
+ rlPhdStackMacAddr PhysAddress
+}
+
+rlPhdStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The stack unit described by this entry."
+ ::= { rlPhdStackEntry 1 }
+
+rlPhdStackType OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the stack unit described by this entry:
+ 1 - box 3202
+ 2 - box LG
+ 3 - bcm
+ 4 - prestera"
+ ::= { rlPhdStackEntry 2 }
+
+rlPhdStackConnect1 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unit number connected to the Hyper GLink left side connection -
+ 0 means not connected; other integer indicates the unit number."
+ DEFVAL { 0 }
+ ::= { rlPhdStackEntry 3 }
+
+rlPhdStackConnect2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unit number connected to the Hyper GLink right side connection -
+ 0 means not connected; other integer indicates the unit number."
+ DEFVAL { 0 }
+ ::= { rlPhdStackEntry 4 }
+
+rlPhdStackSofrwareVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Software version of the unit."
+ ::= { rlPhdStackEntry 5 }
+
+rlPhdStackProductID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Product ID of the unit."
+ ::= { rlPhdStackEntry 6 }
+
+rlPhdStackMacAddr OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical (MAC) address of the unit."
+ ::= { rlPhdStackEntry 7 }
+
+rlPhdModuleHotSwapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdModuleHotSwapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each module (board) there is an entry describing its Hot Swap
+ status"
+ ::= { rlPhysicalDescription 5 }
+
+rlPhdModuleHotSwapEntry OBJECT-TYPE
+ SYNTAX RlPhdModuleHotSwapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a module (board) Hot Swap
+ status"
+ INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex}
+ ::= { rlPhdModuleHotSwapTable 1 }
+
+RlPhdModuleHotSwapEntry ::= SEQUENCE {
+ rlPhdModuleHotSwapAdminStatus INTEGER,
+ rlPhdModuleHotSwapOperStatus INTEGER
+}
+
+rlPhdModuleHotSwapAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired state of the module. The off(1) state indicates
+ that the module is not used and its rlPhdModuleHotSwapOperStatus
+ is always off(2).
+ The on{1) state indicates that the module may be used and its
+ rlPhdModuleHotSwapOperStatus will be on(1) if it presents and
+ off(2) if it does not present."
+ DEFVAL { on }
+ ::= { rlPhdModuleHotSwapEntry 1 }
+
+rlPhdModuleHotSwapOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current Hot Swap state of the module.
+ If rlPhdModuleHotSwapAdminStatus is down(2) then
+ rlPhdModuleHotSwapOperStatus should be down(2). If
+ rlPhdModuleHotSwapAdminStatus is changed to up(1) then
+ rlPhdModuleHotSwapOperStatus should change to
+ up(1) if the module presents; it should remain in the down(2) state if
+ and only if the module does not present."
+ ::= { rlPhdModuleHotSwapEntry 2 }
+
+rlPhdStackOrderTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdStackOrderEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table enables the user to configure the order
+ of the stack units as displayed on his GUI.
+ The order of the entries in this table corresponds
+ to the last configured order. If the stack units order was
+ never configured, the order will be the same as in the rlPhdStackTable."
+ ::= { rlPhysicalDescription 6 }
+
+rlPhdStackOrderEntry OBJECT-TYPE
+ SYNTAX RlPhdStackOrderEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a stack unit in the position desired by the user"
+ INDEX { rlPhdStackOrderCurrentUnitPosition }
+ ::= { rlPhdStackOrderTable 1 }
+
+RlPhdStackOrderEntry ::= SEQUENCE {
+ rlPhdStackOrderCurrentUnitPosition INTEGER,
+ rlPhdStackOrderDesiredUnitPosition INTEGER,
+ rlPhdStackOrderUnitIndex INTEGER,
+ rlPhdStackOrderUnitType INTEGER
+}
+
+rlPhdStackOrderCurrentUnitPosition OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The current stack unit position."
+ ::= { rlPhdStackOrderEntry 1 }
+
+rlPhdStackOrderDesiredUnitPosition OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired stack unit position. Note that setting this MIB
+ object will take effect only after setting the rlPhdStackReorder MIB
+ object below. After setting this MIB object and until a further change
+ of at least one instance of the rlPhdStackOrderDesiredUnitPosition object,
+ the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and
+ the corresponding rlPhdStackOrderDesiredUnitPosition object instance
+ will be the same."
+ ::= { rlPhdStackOrderEntry 2 }
+
+rlPhdStackOrderUnitIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This is the original unit index, i.e. has the same value as rlPhdStackUnit
+ above."
+ ::= { rlPhdStackOrderEntry 3 }
+
+rlPhdStackOrderUnitType OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the stack unit described by this entry. It has the same value
+ as rlPhdStackType above. This information is duplicated here only for easier
+ retrieval by the device manager."
+ ::= { rlPhdStackOrderEntry 4 }
+
+rlPhdStackReorder OBJECT-TYPE
+ SYNTAX INTEGER {reorder(1)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this MIB object will cause the settings of the
+ rlPhdStackOrderDesiredUnitPosition MIB object instances to take effect.
+ After setting this MIB object and until a further change
+ of at least one instance of the rlPhdStackOrderDesiredUnitPosition object,
+ the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and
+ the corresponding rlPhdStackOrderDesiredUnitPosition object instance
+ will be the same."
+ ::= { rlPhysicalDescription 7 }
+
+rlPhdNumberOfUnits OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows the current number of units in the stack."
+ ::= { rlPhysicalDescription 8 }
+
+rlPhdMaxNumberOfUnits OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows the maximum number of units in the stack."
+ ::= { rlPhysicalDescription 9 }
+
+rlPhdForceMasterUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Force unit to be master."
+ ::= { rlPhysicalDescription 10 }
+
+-- The following scalar isn't suported and will be removed
+rlPhdStackFixedUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determine which unit will be on bottom/top of list
+ on Show-List command(see ."
+ ::= { rlPhysicalDescription 11 }
+
+-- The following scalar isn't suported and will be removed
+rlPhdStackFixedUnitLocation OBJECT-TYPE
+ SYNTAX INTEGER{
+ bottom(1),
+ top(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determine the bottom/top object in the stack table."
+ ::= { rlPhysicalDescription 12 }
+
+rlPhdStackReloadUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reset a specific unit."
+ ::= { rlPhysicalDescription 13 }
+
+rlPhdUnitGenParamTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdUnitGenParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each module (board) there is an entry describing it in this
+ module"
+ ::= { rlPhysicalDescription 14 }
+
+rlPhdUnitGenParamEntry OBJECT-TYPE
+ SYNTAX RlPhdUnitGenParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a module (board)"
+ INDEX { rlPhdUnitGenParamStackUnit}
+ ::= { rlPhdUnitGenParamTable 1 }
+
+RlPhdUnitGenParamEntry ::= SEQUENCE {
+ rlPhdUnitGenParamStackUnit INTEGER,
+ rlPhdUnitGenParamSoftwareVersion DisplayString,
+ rlPhdUnitGenParamFirmwareVersion DisplayString,
+ rlPhdUnitGenParamHardwareVersion DisplayString,
+ rlPhdUnitGenParamSerialNum DisplayString,
+ rlPhdUnitGenParamAssetTag DisplayString,
+ rlPhdUnitGenParamServiceTag DisplayString,
+ rlPhdUnitGenParamSoftwareDate DisplayString,
+ rlPhdUnitGenParamFirmwareDate DisplayString,
+ rlPhdUnitGenParamManufacturer DisplayString,
+ rlPhdUnitGenParamModelName DisplayString,
+ rlPhdUnitGenParamMd5ChksumBoot DisplayString,
+ rlPhdUnitGenParamMd5ChksumImage1 DisplayString,
+ rlPhdUnitGenParamMd5ChksumImage2 DisplayString,
+ rlPhdUnitGenParamRegistrationDone TruthValue,
+ rlPhdUnitGenParamRegistrationSuppressed TruthValue
+}
+
+rlPhdUnitGenParamStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The index of the stack unit to which this conceptual row corresponds."
+ ::= { rlPhdUnitGenParamEntry 1 }
+
+rlPhdUnitGenParamSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Serial number of the product."
+ ::= { rlPhdUnitGenParamEntry 2 }
+
+rlPhdUnitGenParamFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Serial number of the product."
+ ::= { rlPhdUnitGenParamEntry 3 }
+
+rlPhdUnitGenParamHardwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Serial number of the product."
+ ::= { rlPhdUnitGenParamEntry 4 }
+
+rlPhdUnitGenParamSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Serial number of the product."
+ ::= { rlPhdUnitGenParamEntry 5 }
+
+rlPhdUnitGenParamAssetTag OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Serial number of the product."
+ ::= { rlPhdUnitGenParamEntry 6 }
+
+rlPhdUnitGenParamServiceTag OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Asset tag of the product."
+ ::= { rlPhdUnitGenParamEntry 7 }
+
+rlPhdUnitGenParamSoftwareDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Date of product's software."
+ ::= { rlPhdUnitGenParamEntry 8 }
+
+rlPhdUnitGenParamFirmwareDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Date of product's firmware."
+ ::= { rlPhdUnitGenParamEntry 9 }
+
+rlPhdUnitGenParamManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Product's Manufacturer."
+ ::= { rlPhdUnitGenParamEntry 10 }
+
+rlPhdUnitGenParamModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Model Name."
+ ::= { rlPhdUnitGenParamEntry 11 }
+
+rlPhdUnitGenParamMd5ChksumBoot OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MD5 Checksum for Boot"
+ ::= { rlPhdUnitGenParamEntry 12 }
+
+rlPhdUnitGenParamMd5ChksumImage1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MD5 Checksum for Image 1"
+ ::= { rlPhdUnitGenParamEntry 13 }
+
+rlPhdUnitGenParamMd5ChksumImage2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "MD5 Checksum for Image 2"
+ ::= { rlPhdUnitGenParamEntry 14 }
+
+rlPhdUnitGenParamRegistrationDone OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Registration Done."
+ ::= { rlPhdUnitGenParamEntry 15 }
+
+rlPhdUnitGenParamRegistrationSuppressed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Registration Suppressed."
+ ::= { rlPhdUnitGenParamEntry 16 }
+
+rlPhdUnitEnvParamTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdUnitEnvParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each module (board) there is an entry describing it in this
+ module"
+ ::= { rlPhysicalDescription 15 }
+
+rlPhdUnitEnvParamEntry OBJECT-TYPE
+ SYNTAX RlPhdUnitEnvParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a module (board)"
+ INDEX { rlPhdUnitEnvParamStackUnit}
+ ::= { rlPhdUnitEnvParamTable 1 }
+
+RlPhdUnitEnvParamEntry ::= SEQUENCE {
+ rlPhdUnitEnvParamStackUnit INTEGER,
+ rlPhdUnitEnvParamMainPSStatus RlEnvMonState,
+ rlPhdUnitEnvParamRedundantPSStatus RlEnvMonState,
+ rlPhdUnitEnvParamFan1Status RlEnvMonState,
+ rlPhdUnitEnvParamFan2Status RlEnvMonState,
+ rlPhdUnitEnvParamFan3Status RlEnvMonState,
+ rlPhdUnitEnvParamFan4Status RlEnvMonState,
+ rlPhdUnitEnvParamFan5Status RlEnvMonState,
+ rlPhdUnitEnvParamTempSensorValue EntitySensorValue,
+ rlPhdUnitEnvParamTempSensorStatus EntitySensorStatus,
+ rlPhdUnitEnvParamUpTime TimeTicks,
+ rlPhdUnitEnvParamMonitorAutoRecoveryEnable TruthValue,
+ rlPhdUnitEnvParamMonitorTemperatureStatus INTEGER,
+ rlPhdUnitEnvParamMonitorOperStatus TruthValue
+}
+
+rlPhdUnitEnvParamStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The index of the stack unit to which this conceptual row corresponds.
+ Note that the index will be the same index as the index
+ of a 'chassis' physical entity in the entity MIB of the product."
+ ::= { rlPhdUnitEnvParamEntry 1 }
+
+rlPhdUnitEnvParamMainPSStatus OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the main PS being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 2 }
+
+rlPhdUnitEnvParamRedundantPSStatus OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the redundant PS being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 3 }
+
+rlPhdUnitEnvParamFan1Status OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the FAN 1 being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 4 }
+
+rlPhdUnitEnvParamFan2Status OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the FAN 2 being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 5 }
+
+rlPhdUnitEnvParamFan3Status OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the FAN 3 being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 6 }
+
+rlPhdUnitEnvParamFan4Status OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the FAN 4 being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 7 }
+
+rlPhdUnitEnvParamFan5Status OBJECT-TYPE
+ SYNTAX RlEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mandatory state of the FAN 5 being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 8 }
+
+rlPhdUnitEnvParamTempSensorValue OBJECT-TYPE
+ SYNTAX EntitySensorValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current value for the Sensor being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 9 }
+
+rlPhdUnitEnvParamTempSensorStatus OBJECT-TYPE
+ SYNTAX EntitySensorStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status value for the Sensor being instrumented."
+ ::= { rlPhdUnitEnvParamEntry 10 }
+
+rlPhdUnitEnvParamUpTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Up time of the unit in 100th of second (sec/100)."
+ ::= { rlPhdUnitEnvParamEntry 11 }
+
+rlPhdUnitEnvParamMonitorAutoRecoveryEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Disable environment automatic recovery option"
+ ::= { rlPhdUnitEnvParamEntry 12 }
+
+rlPhdUnitEnvParamMonitorTemperatureStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ overTemperatureThreshold(2),
+ overCriticalTemperatureThreshold(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display environment monitoring chassis temperature status"
+ ::= { rlPhdUnitEnvParamEntry 13 }
+
+rlPhdUnitEnvParamMonitorOperStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display environment automatic recovery current status (active/not active)"
+ ::= { rlPhdUnitEnvParamEntry 14 }
+
+rlPhdStackOrderTopUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This scalar mib holds the Top unit for the stack order command"
+ ::= { rlPhysicalDescription 16 }
+
+rlPhdStackOrderBottomUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This scalar mib holds the Bottom unit for the stack order command"
+ ::= { rlPhysicalDescription 17 }
+rlPhdStackOrderPermutation OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This scalar mib holds stack permutation"
+ ::= { rlPhysicalDescription 18 }
+
+rlPhdNumberOfPoeUnits OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows the current number of poe units in the stack."
+ ::= { rlPhysicalDescription 19 }
+
+rlPhdPoeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhdPoeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each module (board) there is an entry describing it in this
+ module"
+ ::= { rlPhysicalDescription 20 }
+
+rlPhdPoeEntry OBJECT-TYPE
+ SYNTAX RlPhdPoeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a module (board)"
+ INDEX { rlPhdPoeStackUnit }
+ ::= { rlPhdPoeTable 1 }
+
+RlPhdPoeEntry ::= SEQUENCE {
+ rlPhdPoeStackUnit INTEGER,
+ rlPhdPoePresent INTEGER
+}
+
+rlPhdPoeStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The stack unit to which this module belongs."
+ ::= { rlPhdPoeEntry 1 }
+
+rlPhdPoePresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(1),
+ yes(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present state of the PoE module. The no(1) state indicates
+ that the PoE module is not present. The yes{2) state indicates that the
+ PoE module is present."
+ ::= { rlPhdPoeEntry 2 }
+
+-- The light unit scalars
+rlPhdPhyLedStackUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This scalar mib holds the unit number for the stack light command"
+ ::= { rlPhysicalDescription 21 }
+
+rlPhdPhyLedTimeout OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This scalar mib holds the timeout for the stack light command.
+ May be in the range 2..60 sec. (default - 5 sec.), if the timeout = 0
+ - all units return to normal state."
+ ::= { rlPhysicalDescription 22 }
+
+rlCascadeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlCascadeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each cascaded port for stacking unit there is an entry describing it in this table"
+ ::= { rlPhysicalDescription 23 }
+
+rlCascadeEntry OBJECT-TYPE
+ SYNTAX RlCascadeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry of this table specifies a cascaded link information in a unit"
+ INDEX { ifIndex }
+ ::= { rlCascadeTable 1 }
+
+RlCascadeEntry ::= SEQUENCE {
+ rlCascadeNeighborIfIndex InterfaceIndexOrZero,
+ rlCascadeNeighborUnit INTEGER,
+ rlCascadeTrunkId INTEGER,
+ rlCascadeUnitId INTEGER
+}
+
+rlCascadeNeighborIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of a stacking port in the neighbor unit -
+ 0 means not connected; other integer indicates the IfIndex."
+ ::= { rlCascadeEntry 1 }
+
+rlCascadeNeighborUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unit number of the neighbor unit -
+ 0 means not connected; other integer indicates the unit number."
+ ::= { rlCascadeEntry 2 }
+
+rlCascadeTrunkId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the trunk, the stacking port is member,
+ zero if the port is not member of trunk."
+ ::= { rlCascadeEntry 3 }
+
+rlCascadeUnitId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unit number matching the current ifIndex"
+ ::= { rlCascadeEntry 4 }
+
+rlCascadeAfterResetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlCascadeAfterResetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "For each cascaded port for stacking unit there is an entry describing it in this table after reset"
+ ::= { rlPhysicalDescription 24 }
+
+rlCascadeAfterResetEntry OBJECT-TYPE
+ SYNTAX RlCascadeAfterResetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry of this table specifies a cascaded port information in a unit after reset"
+ INDEX { rlCascadeIfIndexAfterReset }
+ ::= { rlCascadeAfterResetTable 1 }
+
+RlCascadeAfterResetEntry ::= SEQUENCE {
+ rlCascadeIfIndexAfterReset InterfaceIndex,
+ rlCascadeTrunkIdAfterReset INTEGER,
+ rlCascadeRowStatus RowStatus
+}
+
+rlCascadeIfIndexAfterReset OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of a stacking port after reset."
+ ::= { rlCascadeAfterResetEntry 1 }
+
+rlCascadeTrunkIdAfterReset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Id of the trunk, the stacking port will be member after reset,
+ zero if the port is not member of trunk."
+ ::= { rlCascadeAfterResetEntry 2 }
+
+rlCascadeRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "This object indicates the status of this entry."
+ ::= { rlCascadeAfterResetEntry 3 }
+
+
+-- Stack MIB Trap Definitions
+
+rlStackUnitRemoved NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that a unit was removed from the stack."
+ ::= { rndNotifications 186 }
+
+rlStackConfigChangedRingChain NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that the configuration of the stack has changed.
+ - from ring to chain
+ - from chain to ring."
+
+ ::= { rndNotifications 187 }
+
+rlStackBackupUnitRemoved NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that the backup unit was removed from the stack."
+ ::= { rndNotifications 188 }
+
+rlStackMasterSwitchover NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that a new master was elected.
+ The old maste is the backup now. "
+ ::= { rndNotifications 189 }
+
+rlStackUnitDifferentSwVersion NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that the new unit added to the stack has
+ different software version than the master."
+ ::= { rndNotifications 190 }
+
+rlStackDuplicateUnitNotJoin NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that a new unit with duplicated unit id was
+ added to the stack - but it will not join the stack."
+ ::= { rndNotifications 191 }
+
+rlStackLinkChange NOTIFICATION-TYPE
+ OBJECTS { rndErrorDesc, rndErrorSeverity }
+ STATUS current
+ DESCRIPTION
+ "Trap indicating that Link has change in one of the Stacking Ports."
+ ::= { rndNotifications 195 }
+
+END