summaryrefslogtreecommitdiff
path: root/MIBS/junos/JUNIPER-IF-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/junos/JUNIPER-IF-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/junos/JUNIPER-IF-MIB')
-rw-r--r--MIBS/junos/JUNIPER-IF-MIB1179
1 files changed, 1179 insertions, 0 deletions
diff --git a/MIBS/junos/JUNIPER-IF-MIB b/MIBS/junos/JUNIPER-IF-MIB
new file mode 100644
index 0000000..823732e
--- /dev/null
+++ b/MIBS/junos/JUNIPER-IF-MIB
@@ -0,0 +1,1179 @@
+--
+-- Juniper Enterprise Specific MIB: Interface MIB Extension
+--
+-- Copyright (c) 1999-2012, Juniper Networks, Inc.
+-- All rights reserved.
+--
+-- The contents of this document are subject to change without notice.
+--
+
+JUNIPER-IF-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Gauge32, Integer32, Counter64, Counter32, Unsigned32, TimeTicks
+ FROM SNMPv2-SMI
+ CounterBasedGauge64
+ FROM HCNUM-TC
+ ifEntry,ifIndex
+ FROM IF-MIB
+ TimeStamp, TruthValue
+ FROM SNMPv2-TC
+ jnxMibs
+ FROM JUNIPER-SMI;
+
+ifJnx MODULE-IDENTITY
+ LAST-UPDATED "201109221523Z" -- Thu Sept 22 15:23:51 2011 UTC
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Technical Assistance Center
+ Juniper Networks, Inc.
+ 1133 Innovation Way
+ Sunnyvale, CA 94089
+ E-mail: support@juniper.net"
+
+ DESCRIPTION
+ "The MIB modules extends the ifTable as
+ defined in IF-MIB."
+ REVISION "201105100000Z" -- 10 May, 2011
+ DESCRIPTION
+ "New Layer2 Policer Counters Added to ifJnxTable for MX Series only"
+ REVISION "201109220000Z"
+ DESCRIPTION
+ "Added new OIDs Crc and Fcs Erros.
+ Added new Trap ifJnxErrors"
+ REVISION "200706050000Z" -- 05 June, 2007
+ DESCRIPTION
+ "New Time Domain Reflectometery Added"
+ REVISION "200210310000Z" -- 31 Oct, 2002
+ DESCRIPTION
+ "New error counters added to ifJnxTable"
+ REVISION "200106210000Z" -- 21 June, 2001
+ DESCRIPTION
+ "New objects ifHCIn1SecRate and
+ ifHCOut1SecRate added"
+ REVISION "200103150000Z" -- 15 March, 2001
+ DESCRIPTION
+ "New objects ifHCIn1SecOctets and
+ ifHCOut1SecOctets added"
+ REVISION "201510150000Z" -- 14 Oct, 2015
+ DESCRIPTION
+ "Initial Version"
+
+ REVISION "201510150000Z" -- 16 April, 2018
+ DESCRIPTION
+ "Adding table for ifJnxMediaTable"
+ REVISION "202001010000Z" -- 01 Jan, 2020
+ DESCRIPTION
+ "New object ifJnxInputErrors added"
+ ::= { jnxMibs 3 }
+
+
+--
+-- This table augments ifTable
+--
+ ifJnxTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfJnxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Juniper's extension to the interface entries.
+ The number of entries is given by the value of ifNumber.
+ This table contains additional objects for the interface
+ table."
+
+
+ ::= { ifJnx 1 }
+
+ ifJnxEntry OBJECT-TYPE
+ SYNTAX IfJnxEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing additional management information
+ applicable to a particular interface."
+ AUGMENTS { ifEntry }
+ ::= { ifJnxTable 1 }
+
+ IfJnxEntry ::=
+ SEQUENCE {
+ ifIn1SecRate Gauge32,
+ ifIn1SecOctets Gauge32,
+ ifIn1SecPkts Gauge32,
+ ifOut1SecRate Gauge32,
+ ifOut1SecOctets Gauge32,
+ ifOut1SecPkts Gauge32,
+ ifHCIn1SecRate CounterBasedGauge64,
+ ifHCOut1SecRate CounterBasedGauge64,
+ ifJnxInErrors Counter64,
+ ifJnxInFrameErrors Counter64,
+ ifJnxInQDrops Counter64,
+ ifJnxInRunts Counter64,
+ ifJnxInGiants Counter64,
+ ifJnxInDiscards Counter64,
+ ifJnxInHslCrcErrors Counter64,
+ ifJnxInHslFifoOverFlows Counter64,
+ ifJnxInL3Incompletes Counter64,
+ ifJnxInL2ChanErrors Counter64,
+ ifJnxInL2MismatchTimeouts Counter64,
+ ifJnxInInvalidVCs Counter64,
+ ifJnxInFifoErrors Counter32,
+ ifJnxBucketDrops Counter64,
+ ifJnxSramErrors Counter32,
+ ifJnxOutErrors Counter64,
+ ifJnxCollisions Counter64,
+ ifJnxCarrierTrans Counter64,
+ ifJnxOutQDrops Counter64,
+ ifJnxOutAgedErrors Counter64,
+ ifJnxOutFifoErrors Counter32,
+ ifJnxOutHslFifoUnderFlows Counter64,
+ ifJnxOutHslCrcErrors Counter32,
+ ifJnxCrcErrors Counter64,
+ ifJnxFcsErrors Counter64,
+ ifHCIn1SecOctets CounterBasedGauge64,
+ ifHCOut1SecOctets CounterBasedGauge64,
+ ifJnxInputErrors Counter64
+ }
+
+ ifIn1SecRate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bits per second (bps), delivered by
+ this (sub-)layer to its next higher (sub-)layer."
+ ::= { ifJnxEntry 1 }
+
+ ifIn1SecOctets OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets per second (Bps, Bytes per
+ second), delivered by this (sub-)layer to its next
+ higher (sub-)layer."
+ ::= { ifJnxEntry 2 }
+
+ ifIn1SecPkts OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets per second (pps), delivered
+ by this (sub-)layer to its next higher (sub-)layer."
+ ::= { ifJnxEntry 3 }
+
+ ifOut1SecRate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bits per second (bps), delivered by
+ this (sub-)layer to its next lower (sub-)layer."
+ ::= { ifJnxEntry 4 }
+
+ ifOut1SecOctets OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets per second (Bps, Bytes per
+ second), delivered by this (sub-)layer to its next
+ lower (sub-)layer."
+ ::= { ifJnxEntry 5 }
+
+ ifOut1SecPkts OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets per second (pps), delivered
+ by this (sub-)layer to its next lower (sub-)layer."
+ ::= { ifJnxEntry 6 }
+
+ ifHCIn1SecRate OBJECT-TYPE
+ SYNTAX CounterBasedGauge64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bits per second (bps), delivered by
+ this (sub-)layer to its next higher (sub-)layer.
+ This object is a 64 bit version of ifIn1SecRate."
+ ::= { ifJnxEntry 7 }
+
+ ifHCOut1SecRate OBJECT-TYPE
+ SYNTAX CounterBasedGauge64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bits per second (bps), delivered by
+ this (sub-)layer to its next lower (sub-)layer.
+ This object is a 64 bit version of ifOut1SecRate."
+ ::= { ifJnxEntry 8 }
+
+ ifJnxInErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Errors: The sum of the incoming frame aborts and FCS errors."
+ ::= { ifJnxEntry 9 }
+
+ ifJnxInFrameErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Framing Errors: The number of input packets which were
+ misaligned."
+ ::= { ifJnxEntry 10 }
+
+ ifJnxInQDrops OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Drops: The number of packets dropped by the input queue of
+ the I/O Manager ASIC."
+ ::= { ifJnxEntry 11 }
+
+ ifJnxInRunts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Runts: Frames received that are smaller than the runt
+ threshold."
+ ::= { ifJnxEntry 12 }
+
+ ifJnxInGiants OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Giants: Frames received that are larger than the giant
+ threshold."
+ ::= { ifJnxEntry 13 }
+
+ ifJnxInDiscards OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Policed Discards: Frames that the incoming packet match code
+ discarded because they were not recognized or of interest."
+ ::= { ifJnxEntry 14 }
+
+ ifJnxInHslCrcErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HS Link CRC Errors: The number of CRC errors on the
+ high-speed links between the ASICs responsible for handling
+ the router interfaces while receiving packets."
+ ::= { ifJnxEntry 15 }
+
+ ifJnxInHslFifoOverFlows OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HS link FIFO overflows: The number of FIFO overflows on the
+ high-speed links between the ASICs responsible for handling
+ the router interfaces."
+ ::= { ifJnxEntry 16 }
+
+ ifJnxInL3Incompletes OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "L3 incompletes: The number of incoming packets that fail
+ Layer 3 sanity checks of the header."
+ ::= { ifJnxEntry 17 }
+
+ ifJnxInL2ChanErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "L2 channel errors: the number of incoming packets for which
+ the sofware could not find a valid logical interface."
+ ::= { ifJnxEntry 18 }
+
+ ifJnxInL2MismatchTimeouts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "L2 mismatch timeouts: The count of malformed or short packets
+ that cause the incoming packet handler to discard the frame
+ as unreadable."
+ ::= { ifJnxEntry 19 }
+
+ ifJnxInInvalidVCs OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Invalid VCs: Number of cells that arrived for a nonexistent
+ virtual circuit."
+ ::= { ifJnxEntry 20 }
+
+ ifJnxInFifoErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "FIFO errors: The number of FIFO errors in the receive
+ direction as reported by the ASIC on the PIC."
+ ::= { ifJnxEntry 21 }
+
+ ifJnxBucketDrops OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bucket drops: Drops due to traffic load exceeding the
+ interface transmit/receive leaky bucket configuration."
+ ::= { ifJnxEntry 22 }
+
+ ifJnxSramErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SRAM errors: This counter increments when a hardware error
+ has occurred in the SRAM on the PIC."
+ ::= { ifJnxEntry 23 }
+
+ ifJnxOutErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Errors: The sum of the outgoing frame aborts and FCS errors."
+ ::= { ifJnxEntry 24 }
+
+ ifJnxCollisions OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Collisions: The number of output collisions detected on this
+ interface."
+ ::= { ifJnxEntry 25 }
+
+ ifJnxCarrierTrans OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Carrier transitions: The number of times the interface saw
+ the carrier signal transition."
+ ::= { ifJnxEntry 26 }
+
+ ifJnxOutQDrops OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Drops: The number of packets dropped by the output queue of
+ the I/O Manager ASIC."
+ ::= { ifJnxEntry 27 }
+
+ ifJnxOutAgedErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Aged packets: The number of packets that remained in shared
+ packet SDRAM for so long that the system automatically purged
+ them."
+ ::= { ifJnxEntry 28 }
+
+ ifJnxOutFifoErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "FIFO errors: The number of FIFO errors in the transmit
+ direction as reported by the ASIC on the PIC."
+ ::= { ifJnxEntry 29 }
+
+ ifJnxOutHslFifoUnderFlows OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HS link FIFO underflows: The number of FIFO underflows on the
+ high-speed links between the ASICs responsible for handling
+ the router interfaces."
+ ::= { ifJnxEntry 30 }
+
+ ifJnxOutHslCrcErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "HS Link CRC Errors: The number of CRC errors on the
+ high-speed links between the ASICs responsible for handling
+ the router interfaces while transmitting packets."
+ ::= { ifJnxEntry 31 }
+
+ ifJnxCrcErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "CRC Errors: The number of CRC errors"
+ ::= { ifJnxEntry 32 }
+
+ ifJnxFcsErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "FCS Errors: The number of FCS errors"
+ ::= { ifJnxEntry 33 }
+
+ ifHCIn1SecOctets OBJECT-TYPE
+ SYNTAX CounterBasedGauge64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes per second (Bps), delivered by
+ this (sub-)layer to its next higher (sub-)layer.
+ This object is a 64 bit version of ifIn1SecOctets."
+ ::= { ifJnxEntry 34 }
+
+ ifHCOut1SecOctets OBJECT-TYPE
+ SYNTAX CounterBasedGauge64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes per second (Bps), delivered by
+ this (sub-)layer to its next lower (sub-)layer.
+ This object is a 64 bit version of ifOut1SecOctets."
+ ::= { ifJnxEntry 35 }
+
+ ifJnxInputErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Errors: Includes all the input errors except the L3 incompletes
+ Same as ifJnxInErrors - ifJnxInL3Incompletes"
+ ::= { ifJnxEntry 36 }
+
+--
+-- This table augments ifTable to map to Chassis MIB tables
+--
+ ifChassisTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Juniper's extension to the interface entries.
+ The number of entries is given by the value of ifNumber.
+ This table contains additional objects for the interface
+ table to facilitate the identification of interfaces and
+ its mapping into the Chassis MIB tables."
+
+
+ ::= { ifJnx 2 }
+
+ ifChassisEntry OBJECT-TYPE
+ SYNTAX IfChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing additional management information
+ applicable to a particular interface."
+ AUGMENTS { ifEntry }
+ ::= { ifChassisTable 1 }
+
+ IfChassisEntry ::=
+ SEQUENCE {
+ ifChassisFpc Integer32,
+ ifChassisPic Integer32,
+ ifChassisPort Integer32,
+ ifChassisChannel Integer32,
+ ifChassisLogicalUnit Unsigned32,
+ ifChassisPicIndex OCTET STRING
+ }
+
+ ifChassisFpc OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the FPC card on which the interface
+ is located in the chassis. It is the chassis slot
+ in which the FPC card is installed for the specified
+ interface.
+
+ Although the number is labeled from 0 and up in the
+ chassis, the return value for this object always starts
+ from 1 according to Network Management convention.
+ Therefore, a value of zero means there is no real or
+ physical FPC associated with the specified interface."
+ ::= { ifChassisEntry 1 }
+
+ ifChassisPic OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the PIC card on which the interface
+ is located in the chassis. It is the PIC location
+ on the FPC card for the specified interface.
+
+ Although the number is labeled from 0 and up in the
+ chassis, the return value for this object always starts
+ from 1 according to Network Management convention.
+ Therefore, a value of zero means there is no real or
+ physical PIC associated with the specified interface."
+ ::= { ifChassisEntry 2 }
+
+ ifChassisPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the port on the PIC card on which the
+ interface is located in the chassis. It is the port
+ number on the PIC card for the specified interface.
+
+ Although the number is labeled from 0 and up in the
+ chassis, the return value for this object always starts
+ from 1 according to Network Management convention.
+ Therefore, a value of zero means there is no real or
+ physical port associated with the specified interface."
+ ::= { ifChassisEntry 3 }
+
+ ifChassisChannel OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The channel identifier for the specified interface
+ if and only if it is part of a channelized interface.
+
+ Although the channel is numbered from 0 and up in the
+ interface naming, the return value for this object
+ always starts from 1 according to Network Management
+ convention. For the interface which could not be
+ channelized, this object returns zero."
+ ::= { ifChassisEntry 4 }
+
+
+ ifChassisLogicalUnit OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The logical unit number of the specified interface.
+ It is the logical part of the interface that is
+ configured on the physical or channel part if any.
+
+ Although the logical unit number is numbered from 0 and
+ up in the interface naming, the return value for this
+ object always starts from 1 according to Network
+ Management convention. For the interface which is
+ really a physical device, this value returns zero."
+ ::= { ifChassisEntry 5 }
+
+ ifChassisPicIndex OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index or indices for the Chassis MIB tables.
+ This is the instance index which keys into the
+ jnxContentsTable in Chassis MIB.
+
+ For example, it could return an octet string of
+ '8.1.2.0' - meaning a PIC ('8', first digit)
+ at FPC slot 0 ('1-1', second digit minus one if nonzero)
+ PIC number 1 ('2-1', third digit minus one if nonzero)
+ port number whatever (fourth digit currently unused)
+ - which in turn could be plugged in by NMS directly
+ after any MIB objects in the jnxContentsTable, say
+ 'jnxContentsDescr.8.1.2.0', so NMS could get that
+ PIC object for the specified interface.
+
+ This object is valid only for those interfaces having
+ real and physical PIC cards. Otherwise, it returns
+ an octet string of four zeros '0.0.0.0.'"
+ ::= { ifChassisEntry 6 }
+
+ --
+ -- This branch contains all Interface Level PFE Notifications data.
+ --
+ ifJnxNotification OBJECT IDENTIFIER ::= { ifJnx 3 }
+
+ ifJnxNotificationPrefix OBJECT IDENTIFIER ::= { ifJnxNotification 0}
+
+ ifJnxErrors NOTIFICATION-TYPE
+ OBJECTS {
+ ifJnxCrcErrors,
+ ifJnxFcsErrors
+ }
+ STATUS current
+ DESCRIPTION
+ "A ifJnxErrors notification is sent when the value
+ of ifJnxCrcErrors or ifJnxFcsErrors increases."
+
+ ::= { ifJnxNotificationPrefix 1 }
+
+--
+-- This table augments ifTable
+--
+ ifJnxPolTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfJnxPolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Juniper's extension to the interface entries.
+ The number of entries is given by the value of ifNumber.
+ This table contains additional objects for the interface
+ table."
+
+
+ ::= { ifJnx 4 }
+
+ ifJnxPolEntry OBJECT-TYPE
+ SYNTAX IfJnxPolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing additional management information
+ applicable to a particular interface."
+ INDEX { ifIndex }
+ ::= { ifJnxPolTable 1 }
+
+ IfJnxPolEntry ::=
+ SEQUENCE {
+
+ ifJnxInPolLowOctets Counter64,
+ ifJnxInPolLowPkts Counter64,
+ ifJnxInPolLow1SecRate Counter64,
+ ifJnxInPolMLowOctets Counter64,
+ ifJnxInPolMLowPkts Counter64,
+ ifJnxInPolMLow1SecRate Counter64,
+ ifJnxInPolMHighOctets Counter64,
+ ifJnxInPolMHighPkts Counter64,
+ ifJnxInPolMHigh1SecRate Counter64,
+ ifJnxInPolHighOctets Counter64,
+ ifJnxInPolHighPkts Counter64,
+ ifJnxInPolHigh1SecRate Counter64,
+ ifJnxInPolDropOctets Counter64,
+ ifJnxInPolDropPkts Counter64,
+ ifJnxInPolDrop1SecRate Counter64,
+ ifJnxOutPolLowOctets Counter64,
+ ifJnxOutPolLowPkts Counter64,
+ ifJnxOutPolLow1SecRate Counter64,
+ ifJnxOutPolMLowOctets Counter64,
+ ifJnxOutPolMLowPkts Counter64,
+ ifJnxOutPolMLow1SecRate Counter64,
+ ifJnxOutPolMHighOctets Counter64,
+ ifJnxOutPolMHighPkts Counter64,
+ ifJnxOutPolMHigh1SecRate Counter64,
+ ifJnxOutPolHighOctets Counter64,
+ ifJnxOutPolHighPkts Counter64,
+ ifJnxOutPolHigh1SecRate Counter64,
+ ifJnxOutPolDropOctets Counter64,
+ ifJnxOutPolDropPkts Counter64,
+ ifJnxOutPolDrop1SecRate Counter64
+
+ }
+
+ ifJnxInPolLowOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Low Bytes"
+ ::= { ifJnxPolEntry 1 }
+
+
+ ifJnxInPolLowPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Low Pkts"
+ ::= { ifJnxPolEntry 2 }
+
+
+ ifJnxInPolLow1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Low 1 Sec Rate"
+ ::= { ifJnxPolEntry 3 }
+
+
+ ifJnxInPolMLowOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium Low Bytes"
+ ::= { ifJnxPolEntry 4 }
+
+
+ ifJnxInPolMLowPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium Low Pkts"
+ ::= { ifJnxPolEntry 5 }
+
+
+ ifJnxInPolMLow1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium Low 1 Sec Rate"
+ ::= { ifJnxPolEntry 6 }
+
+
+ ifJnxInPolMHighOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium High Bytes"
+ ::= { ifJnxPolEntry 7 }
+
+
+ ifJnxInPolMHighPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium High Pkts"
+ ::= { ifJnxPolEntry 8 }
+
+
+ ifJnxInPolMHigh1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium High 1 Sec Rate"
+ ::= { ifJnxPolEntry 9 }
+
+
+ ifJnxInPolHighOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input High Bytes"
+ ::= { ifJnxPolEntry 10 }
+
+
+ ifJnxInPolHighPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input High Pkts"
+ ::= { ifJnxPolEntry 11 }
+
+
+ ifJnxInPolHigh1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input High 1 Sec Rate"
+ ::= { ifJnxPolEntry 12 }
+
+ ifJnxInPolDropOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Drop Bytes"
+ ::= { ifJnxPolEntry 13 }
+
+
+ ifJnxInPolDropPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Drop Pkts"
+ ::= { ifJnxPolEntry 14 }
+
+
+ ifJnxInPolDrop1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Drop 1 Sec Rate"
+ ::= { ifJnxPolEntry 15 }
+
+ ifJnxOutPolLowOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Low Bytes"
+ ::= { ifJnxPolEntry 16 }
+
+
+ ifJnxOutPolLowPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Low Pkts"
+ ::= { ifJnxPolEntry 17 }
+
+
+ ifJnxOutPolLow1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Low 1 Sec Rate"
+ ::= { ifJnxPolEntry 18 }
+
+
+ ifJnxOutPolMLowOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Medium Low Bytes"
+ ::= { ifJnxPolEntry 19 }
+
+
+ ifJnxOutPolMLowPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Input Medium Low Pkts"
+ ::= { ifJnxPolEntry 20 }
+
+
+ ifJnxOutPolMLow1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Medium Low 1 Sec Rate"
+ ::= { ifJnxPolEntry 21 }
+
+
+ ifJnxOutPolMHighOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Medium High Bytes"
+ ::= { ifJnxPolEntry 22 }
+
+
+ ifJnxOutPolMHighPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Medium High Pkts"
+ ::= { ifJnxPolEntry 23 }
+
+
+ ifJnxOutPolMHigh1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Medium High 1 Sec Rate"
+ ::= { ifJnxPolEntry 24 }
+
+
+ ifJnxOutPolHighOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output High Bytes"
+ ::= { ifJnxPolEntry 25 }
+
+
+ ifJnxOutPolHighPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output High Pkts"
+ ::= { ifJnxPolEntry 26 }
+
+
+ ifJnxOutPolHigh1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output High 1 Sec Rate"
+ ::= { ifJnxPolEntry 27 }
+
+
+ ifJnxOutPolDropOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Drop Bytes"
+ ::= { ifJnxPolEntry 28 }
+
+ ifJnxOutPolDropPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Drop Pkts"
+ ::= { ifJnxPolEntry 29 }
+
+
+ ifJnxOutPolDrop1SecRate OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Logical Interface Policer Output Drop 1 Sec Rate"
+ ::= { ifJnxPolEntry 30 }
+
+--
+-- This table augments ifTable
+--
+ ifJnxMediaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IfJnxMediaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Juniper's extension to the interface media entries.
+ The number of entries is given by the value of ifNumber.
+ This table contains additional objects for the interface
+ table."
+
+
+ ::= { ifJnx 5 }
+
+ ifJnxMediaEntry OBJECT-TYPE
+ SYNTAX IfJnxMediaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing additional management information
+ applicable to a particular interface."
+ INDEX { ifIndex }
+ ::= { ifJnxMediaTable 1 }
+
+
+ IfJnxMediaEntry ::=
+ SEQUENCE {
+
+ ifJnxMediaType INTEGER,
+ ifJnxMediaConfigSpeed Gauge32,
+ ifJnxMediaSpeed Gauge32,
+ ifJnxMediaMaxSpeed Gauge32,
+ ifJnxMediaMode INTEGER,
+ ifJnxMediaConfigMode INTEGER,
+ ifJnxMediaAutoNegotiationEnabled TruthValue,
+ ifJnxMediaLastFlap TimeTicks,
+ ifJnxMediaLastUpdate TimeTicks,
+ ifJnxMediaConfigHighSpeed Gauge32,
+ ifJnxMediaConfigSpeedMap BITS,
+ ifJnxMediaHighSpeed Gauge32
+
+ }
+
+ ifJnxMediaType OBJECT-TYPE
+ SYNTAX INTEGER {
+ copper(1),
+ fiber(2),
+ others(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Media type of an interface."
+ ::= { ifJnxMediaEntry 1 }
+
+ ifJnxMediaConfigSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's configured bandwidth in bits
+ per second. If the bandwidth of the interface is greater than the
+ maximum value reportable by this object then this object should
+ report its maximum value (4,294,967,295) and
+ ifJnxMediaConfigHighSpeed must be used to report the interface's
+ config speed. An interface which is configured to auto-negotiate,
+ this speed will be zero. An interface which is configured to
+ auto-negotiate with 10m-100m, this speed will be one."
+ ::= { ifJnxMediaEntry 2 }
+
+ ifJnxMediaSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's current bandwidth in bits
+ per second. If the bandwidth of the interface is greater than the
+ maximum value reportable by this object then this object should
+ report its maximum value (4,294,967,295). For a sub-layer which has
+ no concept of bandwidth, this object should be zero."
+ ::= { ifJnxMediaEntry 3 }
+
+ ifJnxMediaMaxSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of maximum Speed that an interface can support in units
+ of Gbps."
+ ::= { ifJnxMediaEntry 4 }
+
+ ifJnxMediaMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ halfDuplex(1),
+ fullDuplex(2),
+ others(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An interface's current link mode."
+ ::= { ifJnxMediaEntry 5 }
+
+ ifJnxMediaConfigMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ halfDuplex(1),
+ fullDuplex(2),
+ auto(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An interface's configured link mode."
+ ::= { ifJnxMediaEntry 6 }
+
+ ifJnxMediaAutoNegotiationEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The truth value used to indicate whether port Auto-negotiation
+ is enabled on the given physical port."
+ ::= { ifJnxMediaEntry 7 }
+
+ ifJnxMediaLastFlap OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of time from the last flap of interface state."
+ ::= { ifJnxMediaEntry 8 }
+
+ ifJnxMediaLastUpdate OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of time from the last update of interface state."
+ ::= { ifJnxMediaEntry 9 }
+
+ ifJnxMediaConfigHighSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's configured bandwidth in units
+ of 1,000,000 bits per second. For interfaces
+ which do not vary in bandwidth or for those where no
+ accurate estimation can be made, this object should contain
+ the nominal bandwidth."
+ ::= { ifJnxMediaEntry 10 }
+
+ ifJnxMediaConfigSpeedMap OBJECT-TYPE
+ SYNTAX BITS {
+ auto(0),
+ mbps10(1),
+ mbps100(2),
+ mbps1000(3),
+ mbps2500(4),
+ mbps5000(5),
+ mbps10000(6),
+ mbps25000(7),
+ mbps40000(8),
+ mbps50000(9),
+ mbps100000(10)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's configured bandwidth.
+
+ The bit 'auto(0)' indicates that the speed configured is
+ auto-negotiation.
+
+ The bit 'mbps10(1)' indicates that the speed configured is
+ 10mbps.
+
+ The bit 'mbps100(2)' indicates that the speed configured is
+ 100mbps.
+
+ The bit 'mbps1000(3)' indicates that the speed configured is
+ 1000mbps.
+
+ The bit 'mbps2500(4)' indicates that the speed configured is
+ 2500mbps.
+
+ The bit 'mbps5000(5)' indicates that the speed configured is
+ 5000mbps.
+
+ The bit 'mbps10000(6)' indicates that the speed configured is
+ 10000mbps.
+
+ The bit 'mbps25000(7)' indicates that the speed configured is
+ 25000mbps.
+
+ The bit 'mbps40000(8)' indicates that the speed configured is
+ 40000mbps.
+
+ The bit 'mbps50000(9)' indicates that the speed configured is
+ 50000mbps.
+
+ The bit 'mbps100000(10)' indicates that the speed configured is
+ 100000mbps."
+
+ ::= { ifJnxMediaEntry 11 }
+
+ ifJnxMediaHighSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the interface's current bandwidth in units
+ of 1,000,000 bits per second. For interfaces
+ which do not vary in bandwidth or for those where no
+ accurate estimation can be made, this object should contain
+ the nominal bandwidth."
+ ::= { ifJnxMediaEntry 12 }
+
+END