diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ibm/IBMIROCDIALOUT-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/ibm/IBMIROCDIALOUT-MIB')
| -rw-r--r-- | MIBS/ibm/IBMIROCDIALOUT-MIB | 206 |
1 files changed, 206 insertions, 0 deletions
diff --git a/MIBS/ibm/IBMIROCDIALOUT-MIB b/MIBS/ibm/IBMIROCDIALOUT-MIB new file mode 100644 index 0000000..158c413 --- /dev/null +++ b/MIBS/ibm/IBMIROCDIALOUT-MIB @@ -0,0 +1,206 @@ +-- MIB created 5/06/99 21:06:04, by +-- SMIC (the next generation) version 1.6.29, November 22, 1994. + +IBMIROCDIALOUT-MIB DEFINITIONS ::= BEGIN + +-- From file: "ibmdialOut.mi2" +-- Compile options "G A T M" + +IMPORTS + Counter32, Gauge32, Integer32, TimeTicks, IpAddress + FROM SNMPv2-SMI-v1 + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215 + DisplayString, PhysAddress, TruthValue, RowStatus, + AutonomousType, TestAndIncr + FROM SNMPv2-TC-v1 + enterprises + FROM RFC1155-SMI + ifIndex + FROM IF-MIB; + +ibmIROCroutingDialOut OBJECT IDENTIFIER ::= { ibmIROCrouting 6 } +-- MODULE-IDENTITY +-- LastUpdated +-- 9712150900Z +-- OrgName +-- IBM +-- ContactInfo +-- David D. Chen +-- Sam Henderson +-- IBM Corporation +-- 800 Park, Highway 54 +-- Research Triangle Park, NC 27709-9990 +-- Tel: 1 919 254 6182 +-- E-mail: dchen@vnet.ibm.com +-- Descr +-- DIALOUT + +ibm OBJECT IDENTIFIER ::= { enterprises 2 } +ibmProd OBJECT IDENTIFIER ::= { ibm 6 } +ibm2210 OBJECT IDENTIFIER ::= { ibmProd 72 } +ibmIROC OBJECT IDENTIFIER ::= { ibmProd 119 } +ibmIROCrouting OBJECT IDENTIFIER ::= { ibmIROC 4 } +ibmDialOutTraps OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 0 } +ibmDialOutMIB OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 1 } +ibmDialOutDomains OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 2 } +ibmDialOutConformance OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 3 } +ibmDialOutGeneral OBJECT IDENTIFIER ::= { ibmDialOutMIB 1 } +dialOutCompliances OBJECT IDENTIFIER ::= { ibmDialOutConformance 1 } +dialOutGroups OBJECT IDENTIFIER ::= { ibmDialOutConformance 2 } + +dialOutIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF DialOutIfEntry + ACCESS not-accessible + STATUS mandatory + ::= { ibmDialOutMIB 2 } + +dialOutIfEntry OBJECT-TYPE + SYNTAX DialOutIfEntry + ACCESS not-accessible + STATUS mandatory + INDEX { ifIndex } + ::= { dialOutIfTable 1 } + +DialOutIfEntry ::= SEQUENCE { + dialOutIfUserName DisplayString, + dialOutIfTimeRemaining INTEGER, + dialOutIfInactivityTimer INTEGER, + dialOutIfDTRState INTEGER, + dialOutIfProtocol INTEGER, + dialOutEnableComport TruthValue, + dialOutSendBinary TruthValue, + dialOutSupressGoAhead TruthValue, + dialOutDisableEcho TruthValue, + dialOutPortName DisplayString + } + +dialOutIfUserName OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..253)) +-- Rsyntax OCTET STRING(SIZE(0..253)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "could be null." + ::= { dialOutIfEntry 1 } + +dialOutIfTimeRemaining OBJECT-TYPE + SYNTAX INTEGER(0..2147483647) +-- Units +-- seconds + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of time the connection allowed. + Zero means no limits." + ::= { dialOutIfEntry 2 } + +dialOutIfInactivityTimer OBJECT-TYPE + SYNTAX INTEGER(0..2147483647) +-- Units +-- seconds + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of time the connection is in inactivity state." + ::= { dialOutIfEntry 3 } + +dialOutIfDTRState OBJECT-TYPE + SYNTAX INTEGER { + noChange(0), + on(1), + off(2) + } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 4 } + +dialOutIfProtocol OBJECT-TYPE + SYNTAX INTEGER { + undefined(1), + hose(2), + telnet(3) + } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 5 } + +dialOutEnableComport OBJECT-TYPE + SYNTAX TruthValue +-- Rsyntax INTEGER { +-- true(1), +-- false(2) +-- } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 6 } + +dialOutSendBinary OBJECT-TYPE + SYNTAX TruthValue +-- Rsyntax INTEGER { +-- true(1), +-- false(2) +-- } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 7 } + +dialOutSupressGoAhead OBJECT-TYPE + SYNTAX TruthValue +-- Rsyntax INTEGER { +-- true(1), +-- false(2) +-- } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 8 } + +dialOutDisableEcho OBJECT-TYPE + SYNTAX TruthValue +-- Rsyntax INTEGER { +-- true(1), +-- false(2) +-- } + ACCESS read-only + STATUS mandatory + ::= { dialOutIfEntry 9 } + +dialOutPortName OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..30)) +-- Rsyntax OCTET STRING(SIZE(0..30)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "By setting the value to a string of zero length will + reset the value of this obejct to the node default value, + usuallly is 'ALL_PORTS'." + ::= { dialOutIfEntry 10 } + +dialOutIfGroup OBJECT IDENTIFIER ::= { dialOutGroups 1 } +-- OBJECT-GROUP +-- Status +-- mandatory +-- Descr +-- Conformance group for DIALOUT general information. +-- objects +-- dialOutIfUserName, dialOutIfTimeRemaining, +-- dialOutIfInactivityTimer, dialOutIfDTRState, +-- dialOutIfProtocol, dialOutEnableComport, dialOutSendBinary, +-- dialOutSupressGoAhead, dialOutDisableEcho, dialOutPortName + +dialOutCoreCompliance OBJECT IDENTIFIER ::= { dialOutCompliances 1 } +-- MODULE-COMPLIANCE +-- Status +-- mandatory +-- Descr +-- The core compliance statement for all DIALOUT nodes. +-- Module +-- >>current<< +-- MandGroup +-- dialOutIfGroup + + +END + |