summaryrefslogtreecommitdiff
path: root/MIBS/ibm/IBMIROCDIALOUT-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ibm/IBMIROCDIALOUT-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/ibm/IBMIROCDIALOUT-MIB')
-rw-r--r--MIBS/ibm/IBMIROCDIALOUT-MIB206
1 files changed, 206 insertions, 0 deletions
diff --git a/MIBS/ibm/IBMIROCDIALOUT-MIB b/MIBS/ibm/IBMIROCDIALOUT-MIB
new file mode 100644
index 0000000..158c413
--- /dev/null
+++ b/MIBS/ibm/IBMIROCDIALOUT-MIB
@@ -0,0 +1,206 @@
+-- MIB created 5/06/99 21:06:04, by
+-- SMIC (the next generation) version 1.6.29, November 22, 1994.
+
+IBMIROCDIALOUT-MIB DEFINITIONS ::= BEGIN
+
+-- From file: "ibmdialOut.mi2"
+-- Compile options "G A T M"
+
+IMPORTS
+ Counter32, Gauge32, Integer32, TimeTicks, IpAddress
+ FROM SNMPv2-SMI-v1
+ OBJECT-TYPE
+ FROM RFC-1212
+ TRAP-TYPE
+ FROM RFC-1215
+ DisplayString, PhysAddress, TruthValue, RowStatus,
+ AutonomousType, TestAndIncr
+ FROM SNMPv2-TC-v1
+ enterprises
+ FROM RFC1155-SMI
+ ifIndex
+ FROM IF-MIB;
+
+ibmIROCroutingDialOut OBJECT IDENTIFIER ::= { ibmIROCrouting 6 }
+-- MODULE-IDENTITY
+-- LastUpdated
+-- 9712150900Z
+-- OrgName
+-- IBM
+-- ContactInfo
+-- David D. Chen
+-- Sam Henderson
+-- IBM Corporation
+-- 800 Park, Highway 54
+-- Research Triangle Park, NC 27709-9990
+-- Tel: 1 919 254 6182
+-- E-mail: dchen@vnet.ibm.com
+-- Descr
+-- DIALOUT
+
+ibm OBJECT IDENTIFIER ::= { enterprises 2 }
+ibmProd OBJECT IDENTIFIER ::= { ibm 6 }
+ibm2210 OBJECT IDENTIFIER ::= { ibmProd 72 }
+ibmIROC OBJECT IDENTIFIER ::= { ibmProd 119 }
+ibmIROCrouting OBJECT IDENTIFIER ::= { ibmIROC 4 }
+ibmDialOutTraps OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 0 }
+ibmDialOutMIB OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 1 }
+ibmDialOutDomains OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 2 }
+ibmDialOutConformance OBJECT IDENTIFIER ::= { ibmIROCroutingDialOut 3 }
+ibmDialOutGeneral OBJECT IDENTIFIER ::= { ibmDialOutMIB 1 }
+dialOutCompliances OBJECT IDENTIFIER ::= { ibmDialOutConformance 1 }
+dialOutGroups OBJECT IDENTIFIER ::= { ibmDialOutConformance 2 }
+
+dialOutIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DialOutIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ ::= { ibmDialOutMIB 2 }
+
+dialOutIfEntry OBJECT-TYPE
+ SYNTAX DialOutIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ INDEX { ifIndex }
+ ::= { dialOutIfTable 1 }
+
+DialOutIfEntry ::= SEQUENCE {
+ dialOutIfUserName DisplayString,
+ dialOutIfTimeRemaining INTEGER,
+ dialOutIfInactivityTimer INTEGER,
+ dialOutIfDTRState INTEGER,
+ dialOutIfProtocol INTEGER,
+ dialOutEnableComport TruthValue,
+ dialOutSendBinary TruthValue,
+ dialOutSupressGoAhead TruthValue,
+ dialOutDisableEcho TruthValue,
+ dialOutPortName DisplayString
+ }
+
+dialOutIfUserName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..253))
+-- Rsyntax OCTET STRING(SIZE(0..253))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "could be null."
+ ::= { dialOutIfEntry 1 }
+
+dialOutIfTimeRemaining OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+-- Units
+-- seconds
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time the connection allowed.
+ Zero means no limits."
+ ::= { dialOutIfEntry 2 }
+
+dialOutIfInactivityTimer OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+-- Units
+-- seconds
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time the connection is in inactivity state."
+ ::= { dialOutIfEntry 3 }
+
+dialOutIfDTRState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noChange(0),
+ on(1),
+ off(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 4 }
+
+dialOutIfProtocol OBJECT-TYPE
+ SYNTAX INTEGER {
+ undefined(1),
+ hose(2),
+ telnet(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 5 }
+
+dialOutEnableComport OBJECT-TYPE
+ SYNTAX TruthValue
+-- Rsyntax INTEGER {
+-- true(1),
+-- false(2)
+-- }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 6 }
+
+dialOutSendBinary OBJECT-TYPE
+ SYNTAX TruthValue
+-- Rsyntax INTEGER {
+-- true(1),
+-- false(2)
+-- }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 7 }
+
+dialOutSupressGoAhead OBJECT-TYPE
+ SYNTAX TruthValue
+-- Rsyntax INTEGER {
+-- true(1),
+-- false(2)
+-- }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 8 }
+
+dialOutDisableEcho OBJECT-TYPE
+ SYNTAX TruthValue
+-- Rsyntax INTEGER {
+-- true(1),
+-- false(2)
+-- }
+ ACCESS read-only
+ STATUS mandatory
+ ::= { dialOutIfEntry 9 }
+
+dialOutPortName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..30))
+-- Rsyntax OCTET STRING(SIZE(0..30))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "By setting the value to a string of zero length will
+ reset the value of this obejct to the node default value,
+ usuallly is 'ALL_PORTS'."
+ ::= { dialOutIfEntry 10 }
+
+dialOutIfGroup OBJECT IDENTIFIER ::= { dialOutGroups 1 }
+-- OBJECT-GROUP
+-- Status
+-- mandatory
+-- Descr
+-- Conformance group for DIALOUT general information.
+-- objects
+-- dialOutIfUserName, dialOutIfTimeRemaining,
+-- dialOutIfInactivityTimer, dialOutIfDTRState,
+-- dialOutIfProtocol, dialOutEnableComport, dialOutSendBinary,
+-- dialOutSupressGoAhead, dialOutDisableEcho, dialOutPortName
+
+dialOutCoreCompliance OBJECT IDENTIFIER ::= { dialOutCompliances 1 }
+-- MODULE-COMPLIANCE
+-- Status
+-- mandatory
+-- Descr
+-- The core compliance statement for all DIALOUT nodes.
+-- Module
+-- >>current<<
+-- MandGroup
+-- dialOutIfGroup
+
+
+END
+