diff --git a/MIBS/huawei/HUAWEI-PERFORMANCE-MIB b/MIBS/huawei/HUAWEI-PERFORMANCE-MIB
new file mode 100644
index 0000000..4eb93d6
--- /dev/null
+++ b/MIBS/huawei/HUAWEI-PERFORMANCE-MIB
@@ -0,0 +1,371 @@
+-- ==================================================================
+-- Copyright (C) 2002 by HUAWEI TECHNOLOGIES. All rights reserved.
+--
+-- Description: HUAWEI private rmon alarm Information MIB.
+-- Reference:
+-- Version: V1.0
+-- History:
+-- Created by Qizhenglin, 2002.8.15
+-- ==================================================================
+
+HUAWEI-PERFORMANCE-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ DisplayString
+ FROM RFC1213-MIB
+ OBJECT-TYPE
+ FROM RFC-1212
+ OwnerString
+ FROM IF-MIB
+ hwInternetProtocol
+ FROM HUAWEI-MIB
+ EntryStatus
+ FROM RMON-MIB;
+
+
+ -- This mib is supplementary for RMON-MIB(rfc2819). It includes only one table.
+ -- The mib defines two new objects.One is to set the alarm object by
+ -- expression,the other is to limit the existing time of an alarm row.
+
+ rmonExtend OBJECT IDENTIFIER ::= { hwInternetProtocol 4 }
+
+ performance OBJECT IDENTIFIER ::= { rmonExtend 4 }
+
+
+ prialarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PriAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of alarm entries."
+ ::= { performance 1 }
+
+ prialarmEntry OBJECT-TYPE
+ SYNTAX PriAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of parameters that set up a periodic checking
+ for alarm conditions. For example, an instance of the
+ alarmValue object might be named alarmValue.8"
+ INDEX { prialarmIndex }
+ ::= { prialarmTable 1 }
+
+ PriAlarmEntry ::= SEQUENCE {
+ prialarmIndex INTEGER (1..65535),
+ prialarmInterval INTEGER,
+ prialarmVariable DisplayString,
+ prialarmSympol DisplayString,
+ prialarmSampleType INTEGER,
+ prialarmValue INTEGER,
+ prialarmStartupAlarm INTEGER,
+ prialarmRisingThreshold INTEGER,
+ prialarmFallingThreshold INTEGER,
+ prialarmRisingEventIndex INTEGER (0..65535),
+ prialarmFallingEventIndex INTEGER (0..65535),
+ prialarmStatCycle INTEGER,
+ prialarmStatType INTEGER,
+ prialarmOwner OwnerString,
+ prialarmStatus EntryStatus
+ }
+
+ prialarmIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ alarm table. Each such entry defines a
+ diagnostic sample at a particular interval
+ for an object on the device."
+ ::= { prialarmEntry 1 }
+
+ prialarmInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The interval in seconds over which the data is
+ sampled and compared with the rising and falling
+ thresholds. When setting this variable, care
+ should be taken in the case of deltaValue
+ sampling - the interval should be set short enough
+ that the sampled variable is very unlikely to
+ increase or decrease by more than 2^31 - 1 during
+ a single sampling interval.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 2 }
+
+ prialarmVariable OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled. Only variables that resolve to an ASN.1 primitive
+ type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
+ Gauge, or TimeTicks) may be sampled.
+
+ Because SNMP access control is articulated entirely
+ in terms of the contents of MIB views, no access
+ control mechanism exists that can restrict the value of
+ this object to identify only those objects that exist
+ in a particular MIB view. Because there is thus no
+ acceptable means of restricting the read access that
+ could be obtained through the alarm mechanism, the
+ probe must only grant write access to this object in
+ those views that have read access to all objects on
+ the probe.
+
+ During a set operation, if the supplied variable name is
+ not available in the selected MIB view, a badValue error
+ must be returned. If at any time the variable name of
+ an established alarmEntry is no longer available in the
+ selected MIB view, the probe must change the status of
+ this alarmEntry to invalid(4).
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 3 }
+
+ prialarmSympol OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The string which the alarm line described."
+ ::= {prialarmEntry 4 }
+
+ prialarmSampleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ absoluteValue(1),
+ deltaValue(2),
+ changeratioValue(3)
+ }
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The method of sampling the selected variable and
+ calculating the value to be compared against the
+ thresholds. If the value of this object is
+ absoluteValue(1), the value of the selected variable
+ will be compared directly with the thresholds at the
+ end of the sampling interval. If the value of this
+ object is deltaValue(2), the value of the selected
+ variable at the last sample will be subtracted from
+ the current value, and the difference compared with
+ the thresholds.If the value of this object is
+ changeratioValue(3),the value of the selected variable
+ will be the change ratio of the selected variable,
+ which is that the value of the selected variable at
+ the last sample will be substracted from the current
+ value,and the difference divided by the sampling
+ interval,and the result compared with the thresholds.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 5 }
+
+ prialarmValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of the statistic during the last sampling
+ period. For example, if the sample type is deltaValue,
+ this value will be the difference between the samples
+ at the beginning and end of the period. If the sample
+ type is absoluteValue, this value will be the sampled
+ value at the end of the period.
+ This is the value that is compared with the rising and
+ falling thresholds.
+
+ The value during the current sampling period is not
+ made available until the period is completed and will
+ remain available until the next period completes."
+ ::= { prialarmEntry 6 }
+
+ prialarmStartupAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ risingAlarm(1),
+ fallingAlarm(2),
+ risingOrFallingAlarm(3)
+ }
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm that may be sent when this entry is first
+ set to valid. If the first sample after this entry
+ becomes valid is greater than or equal to the
+ risingThreshold and alarmStartupAlarm is equal to
+ risingAlarm(1) or risingOrFallingAlarm(3), then a single
+ rising alarm will be generated. If the first sample
+ after this entry becomes valid is less than or equal
+ to the fallingThreshold and alarmStartupAlarm is equal
+ to fallingAlarm(2) or risingOrFallingAlarm(3), then a
+ single falling alarm will be generated.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 7 }
+
+ prialarmRisingThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the current
+ sampled value is greater than or equal to this threshold,
+ and the value at the last sampling interval was less than
+ this threshold, a single event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is greater than or
+ equal to this threshold and the associated
+ alarmStartupAlarm is equal to risingAlarm(1) or
+ risingOrFallingAlarm(3).
+
+ After a rising event is generated, another such event
+ will not be generated until the sampled value
+ falls below this threshold and reaches the
+ alarmFallingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 8 }
+
+ prialarmFallingThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the current
+ sampled value is less than or equal to this threshold,
+ and the value at the last sampling interval was greater than
+ this threshold, a single event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is less than or
+ equal to this threshold and the associated
+ alarmStartupAlarm is equal to fallingAlarm(2) or
+ risingOrFallingAlarm(3).
+
+ After a falling event is generated, another such event
+ will not be generated until the sampled value
+ rises above this threshold and reaches the
+ alarmRisingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 9 }
+
+ prialarmRisingEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a rising threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 10 }
+
+ prialarmFallingEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a falling threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { prialarmEntry 11 }
+
+ prialarmStatCycle OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ " The time alarm line exists. When the value
+ of prialarmStatType is during(2),set prialarmStatCycle
+ to decide how long the alarm line exists."
+ ::= { prialarmEntry 12 }
+
+
+ prialarmStatType OBJECT-TYPE
+ SYNTAX INTEGER{
+ forever(1),
+ during(2)
+ }
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "It expresses alarm state type.To choose forever(1)
+ , the alarm line will exist forever. To choose
+ during(2) , the alarm line will be deleted after
+ the time setting for 'prialarmStatCycle'."
+ ::= { prialarmEntry 13 }
+
+ prialarmOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { prialarmEntry 14 }
+
+ prialarmStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-create
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this alarm entry."
+ ::= { prialarmEntry 15 }
+
+ -- extend from Remote Network Monitoring Traps
+
+ rmonExtendEventsV2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Definition point for pri RMON notifications."
+ ::= { rmonExtend 0 }
+
+ pririsingAlarm NOTIFICATION-TYPE
+ OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType,
+ prialarmValue, prialarmRisingThreshold }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm
+ entry crosses its rising threshold and generates
+ an event that is configured for sending SNMP
+ traps."
+ ::= { rmonExtendEventsV2 1 }
+
+ prifallingAlarm NOTIFICATION-TYPE
+ OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType,
+ prialarmValue, prialarmFallingThreshold }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm
+ entry crosses its falling threshold and generates
+ an event that is configured for sending SNMP
+ traps."
+ ::= { rmonExtendEventsV2 2 }
+
+END