diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/hp/HP-ICF-VG-RPTR | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/hp/HP-ICF-VG-RPTR')
| -rw-r--r-- | MIBS/hp/HP-ICF-VG-RPTR | 1094 |
1 files changed, 1094 insertions, 0 deletions
diff --git a/MIBS/hp/HP-ICF-VG-RPTR b/MIBS/hp/HP-ICF-VG-RPTR new file mode 100644 index 0000000..c8ca8d2 --- /dev/null +++ b/MIBS/hp/HP-ICF-VG-RPTR @@ -0,0 +1,1094 @@ + HP-ICF-VG-RPTR DEFINITIONS ::= BEGIN + + IMPORTS + Integer32, Counter32, Counter64, + OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE + FROM SNMPv2-SMI + DisplayString, TruthValue + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP + FROM SNMPv2-CONF + icfVgPortStatus + FROM ICF-VG-RPTR + hpicfObjectModules, hpicfVg, hpicfVgRptrTrapsPrefix + FROM HP-ICF-OID; + + hpicfVgRptrMib MODULE-IDENTITY + LAST-UPDATED "200011032225Z" -- November 3, 2000 + ORGANIZATION "Hewlett Packard Company, + Network Infrastructure Solutions" + CONTACT-INFO + "Hewlett Packard Company + 8000 Foothills Blvd. + Roseville, CA 95747" + DESCRIPTION + "This MIB module contains objects that provide + HP-specific extensions to the 802.12 Repeater MIB." + + REVISION "200011032225Z" -- November 3, 2000 + DESCRIPTION "Updated division name." + + REVISION "9703060345Z" -- March 6, 1997 + DESCRIPTION + "Added NOTIFICATION-GROUP information." + REVISION "9609100236Z" -- September 10, 1996 + DESCRIPTION + "Updated division name and STATUS clauses." + REVISION "9602142253Z" -- February 14, 1996 + DESCRIPTION + "Split this MIB module from the former monolithic + hp-icf MIB. Added redundant uplink support and + additional global counters for standard-compliant + hardware support." + REVISION "9501180000Z" -- January 18, 1995 + DESCRIPTION + "Initial version of this MIB module. Released with + the HPJ2414A agent card for the HPJ2410A 100VG + repeater." + ::= { hpicfObjectModules 11 } + + + + hpVgBasic OBJECT IDENTIFIER ::= { hpicfVg 1 } + hpVgBasicGlobal OBJECT IDENTIFIER ::= { hpVgBasic 1 } + + hpVgEntityName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The local name of this 100BaseVG repeater. This is + the same value as hpicfEntityName in the case where + there is Distributed Management Protocol to access + this device. + + For SNMPv1, this name is appended to the agent + community name to obtain a community name to use + to specify that the agent should proxy to this + repeater. For example, if this agent has a + community with a community name of 'public', and + the value of this object is 'repeater1', the + community 'public/repeater1' will specify that the + agent should proxy to the public community of the + repeater1 box to obtain management information + about this repeater. + + If an agent receives a management request where + the localEntity is not specified, it will default + to the local repeater on which this agent is + executing." + ::= { hpVgBasicGlobal 1 } + + hpVgRedundantUpLinksFlag OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to indicate that the hub + is configured with redundant uplink ports." + ::= { hpVgBasicGlobal 2 } + + hpVgXcvrTable OBJECT-TYPE + SYNTAX SEQUENCE OF HpVgXcvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information about transceivers. + All uplink, downlink, and redundent links are + represented in this table" + ::= { hpVgBasicGlobal 3 } + + hpVgXcvrEntry OBJECT-TYPE + SYNTAX HpVgXcvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the transceiver table" + INDEX { hpVgXcvrGroupIndex , hpVgXcvrIndex } + ::= { hpVgXcvrTable 1 } + + HpVgXcvrEntry ::= + SEQUENCE { + hpVgXcvrGroupIndex Integer32, + hpVgXcvrIndex Integer32, + hpVgXcvrType INTEGER, + hpVgXcvrAssociatedPort Integer32, + hpVgXcvrState INTEGER, + hpVgXcvrAbandonments Counter32, + hpVgXcvrIsMovable TruthValue + } + + hpVgXcvrGroupIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The group within the repeater for which this entry + contains information. This object has the same value + as the corresponding instance of icfVgGroupIndex." + ::= { hpVgXcvrEntry 1 } + + hpVgXcvrIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The transceiver within the group for which this + entry contains information." + ::= { hpVgXcvrEntry 2 } + + hpVgXcvrType OBJECT-TYPE + SYNTAX INTEGER { + other(1), + unknown(2), + pmdMissing(3), + utp4(4), + stp2(5), + fibre(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of physical media supported by this + transceiver. One of the following values: + + other undefined + unknown true state not known + pmdMissing PMD device not attached + utp4 4-pair unshielded twisted pair + stp2 2-pair shielded twisted pair + fibre 802.12 fibre optic cabling + + This object may be 'unknown' if the implementation is + not capable of identifying the PMD media type, or + whether or not the PMD is even present." + ::= { hpVgXcvrEntry 3 } + + hpVgXcvrAssociatedPort OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The port within the group that this transceiver is + associated with. There may be multiple transceivers + associated with a single port. Also, a transceiver + may be moved between ports." + ::= { hpVgXcvrEntry 4 } + + hpVgXcvrState OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + inUse(2), + standby(3), + silent(4), + linkFailure(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is set to 'unknown' if the transceiver + is not present or its status cannot be determined. + 'inUse' indicates that the transceiver is currently + selected for use by its associated port. 'standby' + indicates the associated port is using another + tranceiver, but this tranceiver could be used if + needed. 'silent' indicates that the tranceiver is + not detecting any tones on the link. 'linkFailure' + indicates that the tranceiver was unable to train for + some reason." + ::= { hpVgXcvrEntry 5 } + + hpVgXcvrAbandonments OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of times the corresponding instance + of the hpVgXcvrState object has entered the + 'abandoned' state. For downlink ports this object + will have the value 0." + ::= { hpVgXcvrEntry 6 } + + hpVgXcvrIsMovable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A true value indicates that the transceiver can be + associated with a single port from a set of multiple + ports. A false value indicates that a transceiver + can only be associated with a single, fixed, port" + ::= { hpVgXcvrEntry 7 } + + + hpVgNullAddrTraining OBJECT-TYPE + SYNTAX INTEGER { + preventNullAddr(1), + allowNullAddr(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to control whether the repeater + will allow completion of training by end-nodes using + null MAC addresses. The 802.12 standard is written + to disallow such training. However, some end-nodes + may use this configuration at power-up before any + software is loaded. If so, the user may see frequent + training occurring on the repeater because of this. + In addition, some end-node applications may not work + when initial training fails due to the locking out of + null MAC addresses. + + The default setting of this object is to allow null + MAC addresses to train. This is recommended for most + situations, despite the fact that it contradicts the + 802.12 standard. + + For repeaters that have First Learned address + security on this hub, disallowing null-address + training provides the most extensive security until + the ports' authorized addresses are learned. + However, if this creates problems for the end-node + applications, it may be necessary to instead + explicitly assign the ports' authorized addresses + and configure this object to allow null-address + training." + ::= { hpVgBasicGlobal 4 } + + + hpVgBasicGroup OBJECT IDENTIFIER ::= { hpVgBasic 2 } + + hpVgBasicGroupTable OBJECT-TYPE + SYNTAX SEQUENCE OF HpVgBasicGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "HP specific extensions to the vgBasicGroupTable." + ::= { hpVgBasicGroup 1 } + + hpVgBasicGroupEntry OBJECT-TYPE + SYNTAX HpVgBasicGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table, containing HP extensions + for a specific group." + INDEX { hpVgGrpGroupIndex } + ::= { hpVgBasicGroupTable 1 } + + HpVgBasicGroupEntry ::= + SEQUENCE { + hpVgGrpGroupIndex Integer32, + hpVgGrpPortsAdminStatus OCTET STRING, + hpVgGrpPortsTrained OCTET STRING, + hpVgGrpPortsInTraining OCTET STRING, + hpVgGrpPortsCascaded OCTET STRING, + hpVgGrpPortsPromiscuous OCTET STRING + } + + hpVgGrpGroupIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The group within the repeater for which this entry + contains information. This object has the same value + as the corresponding instance of icfVgGroupIndex." + ::= { hpVgBasicGroupEntry 1 } + + hpVgGrpPortsAdminStatus OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hpVgGrpPortsAdminStatus is a bit map of the + state of the icfVgPortAdminStatus object for all + of the ports in this group. The object has a one + bit for each port for which the value of + icfVgPortAdminStatus is equal to 'enabled(1)' and + a zero bit for each port for which the value of + icfVgPortAdminStatus is equal to 'disabled(2)'. + + The bits are placed into the OCTET STRING in the + following order: + + octet 0 octet 1 octet 2 ... + bits 7-0 bits 7-0 bits 7-0 ... + ports 1-8 ports 9-16 ports 17-24 ... + + Values of unused bits in the last octet are + undefined." + ::= { hpVgBasicGroupEntry 2 } + + hpVgGrpPortsTrained OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hpVgGrpPortsTrained is a bit map which indicates + which ports in this group are currently online. The + object has a one bit for each port for which meets + the following conditions: + + 1. The value of the corresponding instance of the + ifVgPortAdminStatus object is equal to + 'enabled(1)'. + 2. The value of the corresponding instance of the + icfVgPortStatus object is equal to 'active(1)'. + + The object has a zero bit for each port which does + not meet the above conditions. + + The bits are placed into the OCTET STRING in the + following order: + + octet 0 octet 1 octet 2 ... + bits 7-0 bits 7-0 bits 7-0 ... + ports 1-8 ports 9-16 ports 17-24 ... + + Values of unused bits in the last octet are + undefined." + ::= { hpVgBasicGroupEntry 3 } + + hpVgGrpPortsInTraining OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hpVgGrpPortsInTraining is a bit map which + indicates which ports in this group are currently in + the training state. The object has a one bit for + each port which meets the following conditions: + + 1. The value of the corresponding instance of the + ifVgPortAdminStatus object is equal to + 'enabled(1)'. + 2. The value of the corresponding instance of the + icfVgPortStatus object is equal to + 'training(3)'. + + The object has a zero bit for each port which does + not meet the above conditions. + + The bits are placed into the OCTET STRING in the + following order: + + octet 0 octet 1 octet 2 ... + bits 7-0 bits 7-0 bits 7-0 ... + ports 1-8 ports 9-16 ports 17-24 ... + + Values of unused bits in the last octet are + undefined." + ::= { hpVgBasicGroupEntry 4 } + + hpVgGrpPortsCascaded OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hpVgGrpPortsCascaded is a bit map which + indicates which ports in this group have trained as + cascaded repeater ports. The object has a one bit + for each port which meets the following conditions: + + 1. The value of the corresponding instance of the + ifVgPortAdminStatus object is equal to + 'enabled(1)'. + 2. The value of the corresponding instance of the + icfVgPortStatus object is equal to + 'active(1)'. + 3. The value of the 'R' bit in the corresponding + instance of the icfVgPortTrainingResult object + is equal to one. + + The object has a zero bit for each port which does + not meet the above conditions. + + The bits are placed into the OCTET STRING in the + following order: + + octet 0 octet 1 octet 2 ... + bits 7-0 bits 7-0 bits 7-0 ... + ports 1-8 ports 9-16 ports 17-24 ... + + Values of unused bits in the last octet are + undefined." + ::= { hpVgBasicGroupEntry 5 } + + hpVgGrpPortsPromiscuous OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hpVgGrpPortsPromiscuous is a bit map which + indicates which ports in this group have trained for + promiscuous operation. The object has a one bit for + each port which meets the following conditions: + + 1. The value of the corresponding instance of the + ifVgPortAdminStatus object is equal to + 'enabled(1)'. + 2. The value of the corresponding instance of the + icfVgPortStatus object is equal to + 'active(1)'. + 3. The value of the 'PP' field in the corresponding + instance of the icfVgPortTrainingResult object + is equal to 01. + + The object has a zero bit for each port which does + not meet the above conditions. + + The bits are placed into the OCTET STRING in the + following order: + + octet 0 octet 1 octet 2 ... + bits 7-0 bits 7-0 bits 7-0 ... + ports 1-8 ports 9-16 ports 17-24 ... + + Values of unused bits in the last octet are + undefined." + ::= { hpVgBasicGroupEntry 6 } + + hpVgBasicPort OBJECT IDENTIFIER ::= { hpVgBasic 3 } + + hpVgBasicPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF HpVgBasicPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "HP specific extensions to the vg port table." + ::= { hpVgBasicPort 1 } + + hpVgBasicPortEntry OBJECT-TYPE + SYNTAX HpVgBasicPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "HP extended information about a specific vg port." + INDEX { hpVgPortGroupIndex, hpVgPortIndex } + ::= { hpVgBasicPortTable 1 } + + HpVgBasicPortEntry ::= + SEQUENCE { + hpVgPortGroupIndex Integer32, + hpVgPortIndex Integer32, + hpVgPortPolarityReversed TruthValue, + hpVgPortWireSkewError TruthValue, + hpVgPortAssociatedXcvrIndex Integer32, + hpVgPortNumAssociatedXcvrs Integer32 + } + + hpVgPortGroupIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The group that contains the port for which this + entry contains information." + ::= { hpVgBasicPortEntry 1 } + + hpVgPortIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The port within the group for which this entry + contains information." + ::= { hpVgBasicPortEntry 2 } + + hpVgPortPolarityReversed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to indicate that the hub port + was wired with the positive/negative polarity of its + wire pairs reversed. Note that the port will + continue to operate in this state, with the hub + inverting the polarity internally." + ::= { hpVgBasicPortEntry 3 } + + hpVgPortWireSkewError OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to indicate that a wire skew + error has been detected on this port." + ::= { hpVgBasicPortEntry 4 } + + hpVgPortAssociatedXcvrIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is the index into the transceiver table, + hpVgXcvrTable. The transceiver entry defines which + transceiver is connected to the port. This object + will be set to 0 if the port is not currently + associated with a transceiver" + ::= { hpVgBasicPortEntry 5 } + + hpVgPortNumAssociatedXcvrs OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of transceivers that are + currently associated with this port via the + hpVgXcvrTable." + ::= { hpVgBasicPortEntry 6 } + + hpVgMonitor OBJECT IDENTIFIER ::= { hpicfVg 2 } + + hpVgMonitorGlobal OBJECT IDENTIFIER ::= { hpVgMonitor 1 } + + -- Note: The hpVgMonitorGlobal counters that are composed of + -- other objects are provided to allow for event testing on + -- global error conditions. + + hpVgMonCounters OBJECT IDENTIFIER ::= { hpVgMonitorGlobal 1 } + + hpVgMonGlbReadableFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the total number of good frames of + valid frame length that have been received on all + ports in this repeater. This counter is the + summation of the values of the + icfVgPortReadableFrames counter for all of the ports + in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aReadableFramesReceived." + ::= { hpVgMonCounters 1 } + + hpVgMonGlbReadableOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in good frames that have been received on + all ports in this repeater. This counter is the + summation of the values of the + icfVgPortReadableOctets counter for all of the ports + in this repeater. + + Note that this counter will roll over very quickly. + It is provided for backward compatibility for Network + Management protocols that do not support 64 bit + counters (e.g. SNMP version 1)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aReadableOctetsReceived." + ::= { hpVgMonCounters 2 } + + hpVgMonGlbUnreadableOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in invalid frames that have been received + on all ports in this repeater. This counter is the + summation of the values of icfVgPortUnreadableOctets + counter for all of the ports in this repeater. + + Note that this counter will roll over very quickly. + It is provided for backward compatibility for Network + Management protocols that do not support 64 bit + counters (e.g. SNMP version 1)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aOctetsInUnreadableFramesRcvd." + ::= { hpVgMonCounters 3 } + + hpVgMonGlbHighPriorityFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of high + priority frames that have been received on all ports + in this repeater. This counter is a summation of the + values of the icfVgPortHighPriorityFrames counter for + all of the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aHighPriorityFramesReceived." + ::= { hpVgMonCounters 4 } + + hpVgMonGlbHighPriorityOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in high priority frames that have been + received on all ports of this repeater. This counter + is a summation of the values of the + icfVgPortHighPriorityOctets counter for all of the + ports in this repeater. + + Note that this counter will roll over very quickly. + It is provided for backward compatibility for Network + Management protocols that do not support 64 bit + counters (e.g. SNMP version 1)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aHighPriorityOctetsReceived." + ::= { hpVgMonCounters 5 } + + hpVgMonGlbBroadcastFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + broadcast packets that have been received on all + ports in this repeater. This counter is a summation + of the values of the icfVgPortBroadcastFrames counter + for all of the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aBroadcastFramesReceived." + ::= { hpVgMonCounters 6 } + + hpVgMonGlbMulticastFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + multicast packets that have been received on all + ports in this repeater. This counter is a summation + of the values of the icfVgPortMulticastFrames counter + for all of the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aMulticastFramesReceived." + ::= { hpVgMonCounters 7 } + + hpVgMonGlbIPMFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of frames + that have been received on all ports in this repeater + with an invalid packet marker. This counter is a + summation of the values of the icfVgPortIPMFrames + counter for all of the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aIPMFramesReceived." + ::= { hpVgMonCounters 8 } + + hpVgMonGlbDataErrorFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + errored frames received on all ports in this + repeater. This counter is a summation of the values + of the icfVgPortDataErrorFrames counter for all of + the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aDataErrorFramesReceived." + ::= { hpVgMonCounters 9 } + + hpVgMonGlbPriorityPromotions OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + times the priority promotion timer has expired on + any port in this repeater. This counter is a + summation of the values of the + icfVgPortPriorityPromotions counter for all of the + ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aPriorityPromotions." + ::= { hpVgMonCounters 10 } + + hpVgMonGlbHCReadableOctets OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in good frames that have been received on + all ports in this repeater. This counter is the + summation of the values of the + icfVgPortReadableOctets counter for all of the ports + in this repeater. + + This counter is a 64 bit version of + hpVgMonGlbReadableOctets. It should be used by + Network Management protocols which support 64 bit + counters (e.g. SNMPv2)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aReadableOctetsReceived." + ::= { hpVgMonCounters 11 } + + hpVgMonGlbHCUnreadableOctets OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in invalid frames that have been received + on all ports in this repeater. This counter is the + summation of the values of icfVgPortUnreadableOctets + counter for all of the ports in this repeater. + + This counter is a 64 bit version of + hpVgMonGlbUnreadableOctets. It should be used by + Network Management protocols which support 64 bit + counters (e.g. SNMPv2)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aOctetsInUnreadableFramesRcvd." + ::= { hpVgMonCounters 12 } + + hpVgMonGlbHCHighPriorityOctets OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in high priority frames that have been + received on all ports of this repeater. This counter + is a summation of the values of the + icfVgPortHighPriorityOctets counter for all of the + ports in this repeater. + + This counter is a 64 bit version of + hpVgMonGlbHighPriorityOctets. It should be used by + Network Management protocols which support 64 bit + counters (e.g. SNMPv2)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aHighPriorityOctetsReceived." + ::= { hpVgMonCounters 13 } + + hpVgMonGlbHCNormPriorityOctets OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of octets + contained in normal priority frames that have been + received on all ports of this repeater. This counter + is a summation of the values of the + icfVgPortNormPriorityOctets counter for all of the + ports in this repeater. + + This counter is a 64 bit version of + hpVgMonGlbNormPriorityOctets. It should be used by + Network Management protocols which support 64 bit + counters (e.g. SNMPv2)." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aNormalPriorityOctetsReceived." + ::= { hpVgMonCounters 14 } + + hpVgMonGlbNormPriorityFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + normal priority frames received on all ports in this + repeater. This counter is a summation of the values + of the icfVgPortNormPriorityFrames counter for all of + the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aNormalPriorityFramesReceived." + ::= { hpVgMonCounters 15 } + + hpVgMonGlbNormPriorityOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + normal priority octets received on all ports in this + repeater. This counter is a summation of the values + of the icfVgPortNormPriorityOctets counter for all of + the ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aNormalPriorityOctetsReceived." + ::= { hpVgMonCounters 16 } + + hpVgMonGlbNullAddressedFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of null + addressed packets that have been received on all + ports. This counter is a summation of the values of + the icfVgPortNullAddressedFrames counter for the + ports in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aNullAddressedFramesReceived." + ::= { hpVgMonCounters 17 } + + hpVgMonGlbOversizeFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + oversized frames that have been received on all + ports. This counter is a summation of the values of + the icfVgPortOversizeFrames counter for the ports in + this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aOversizeFramesReceived." + ::= { hpVgMonCounters 18 } + + hpVgMonGlbTransitionToTrainings OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is a count of the total number of + transitions to training on all ports. This counter is + a summation of the values of the + icfVgPortTransitionToTrainings counter for the ports + in this repeater." + REFERENCE + "IEEE Draft Std. 802.12, Draft 6, 23 November, 1994, + 13.2.4.5.1, aTransitionsIntoTraining." + ::= { hpVgMonCounters 19 } + + + hpVgMonitorGroup OBJECT IDENTIFIER ::= { hpVgMonitor 2 } + -- unused + + hpVgMonitorPort OBJECT IDENTIFIER ::= { hpVgMonitor 3 } + -- unused + + -- VG Repeater Specific traps + + + hpVgRedundantUplinkTrap NOTIFICATION-TYPE + OBJECTS { hpVgXcvrState } + STATUS current + DESCRIPTION + "An hpVgRedundantUplinkTrap is sent anytime one of + the tranceivers being used in a redundant uplink + transitions from one of the 'unknown', 'inUse' or + 'standby' states to either the 'silent' or + 'linkFailure' state. + + The hpVgXcvrState is the new value of the tranceiver + state for the tranceiver that made the transition." + ::= { hpicfVgRptrTrapsPrefix 1 } + + hpVgLossOfActiveTrap NOTIFICATION-TYPE + OBJECTS { icfVgPortStatus } + STATUS current + DESCRIPTION + "An hpVgLossOfActiveTrap is sent whenever an enabled + port transitions from the active state to either the + inactive or training state. The new value of the + port's status is returned in the trap." + ::= { hpicfVgRptrTrapsPrefix 2 } + + + -- conformance information + + hpicfVgRptrConformance + OBJECT IDENTIFIER ::= { hpicfVgRptrMib 1 } + + hpicfVgRptrCompliances + OBJECT IDENTIFIER ::= { hpicfVgRptrConformance 1 } + hpicfVgRptrGroups + OBJECT IDENTIFIER ::= { hpicfVgRptrConformance 2 } + + -- compliance statements + + hpicfVgRptrPreDot12Compliance MODULE-COMPLIANCE + STATUS obsolete + DESCRIPTION + "********* THIS COMPLIANCE IS OBSOLETE ********* + + The compliance statement for pre-standard HP 100VG + repeaters." + MODULE + MANDATORY-GROUPS { hpicfVgRptrPreDot12BasicGroup, + hpicfVgRptrPreDot12MonitorGroup } + + ::= { hpicfVgRptrCompliances 1 } + + hpicfVgRptrCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for HP 802.12 repeaters." + MODULE + MANDATORY-GROUPS { hpicfVgRptrBasicGroup, + hpicfVgRptrMonitorGroup, + hpicfVgRptrXcvrGroup, + hpicfVgRptrBasicTraps } + + GROUP hpicfVgRptrRedundantUplinkGroup + DESCRIPTION + "This group should be implemented on 802.12 + repeaters that support redundant uplinks." + + GROUP hpicfVgRptrRedundantUplinkTraps + DESCRIPTION + "This group should be implemented on 802.12 + repeaters that support redundant uplinks." + + ::= { hpicfVgRptrCompliances 2 } + + + -- units of conformance + + hpicfVgRptrPreDot12BasicGroup OBJECT-GROUP + OBJECTS { hpVgEntityName, + hpVgGrpPortsAdminStatus, + hpVgGrpPortsTrained, + hpVgGrpPortsInTraining, + hpVgGrpPortsCascaded, + hpVgGrpPortsPromiscuous, + hpVgPortPolarityReversed, + hpVgPortWireSkewError + } + STATUS obsolete + DESCRIPTION + "********* THIS GROUP IS OBSOLETE ********* + + HP specific extensions to the 802.12 Repeater MIB + providing status and configuration of pre-standard + 802.12 repeaters." + ::= { hpicfVgRptrGroups 1 } + + hpicfVgRptrBasicGroup OBJECT-GROUP + OBJECTS { hpVgEntityName, + hpVgNullAddrTraining, + hpVgGrpPortsAdminStatus, + hpVgGrpPortsTrained, + hpVgGrpPortsInTraining, + hpVgGrpPortsCascaded, + hpVgGrpPortsPromiscuous, + hpVgPortPolarityReversed, + hpVgPortWireSkewError + } + STATUS current + DESCRIPTION + "HP specific extensions to the 802.12 Repeater MIB + providing status and configuration of 802.12 + repeaters." + ::= { hpicfVgRptrGroups 2 } + + hpicfVgRptrPreDot12MonitorGroup OBJECT-GROUP + OBJECTS { hpVgMonGlbReadableFrames, + hpVgMonGlbReadableOctets, + hpVgMonGlbUnreadableOctets, + hpVgMonGlbHighPriorityFrames, + hpVgMonGlbHighPriorityOctets, + hpVgMonGlbBroadcastFrames, + hpVgMonGlbMulticastFrames, + hpVgMonGlbIPMFrames, + hpVgMonGlbDataErrorFrames, + hpVgMonGlbPriorityPromotions, + hpVgMonGlbHCReadableOctets, + hpVgMonGlbHCUnreadableOctets, + hpVgMonGlbHCHighPriorityOctets + } + STATUS obsolete + DESCRIPTION + "********* THIS GROUP IS OBSOLETE ********* + + HP specific extensions to the 802.12 Repeater MIB + providing global counters for pre-standard 802.12 + repeaters." + ::= { hpicfVgRptrGroups 3 } + + hpicfVgRptrMonitorGroup OBJECT-GROUP + OBJECTS { hpVgMonGlbReadableFrames, + hpVgMonGlbReadableOctets, + hpVgMonGlbUnreadableOctets, + hpVgMonGlbHighPriorityFrames, + hpVgMonGlbHighPriorityOctets, + hpVgMonGlbBroadcastFrames, + hpVgMonGlbMulticastFrames, + hpVgMonGlbIPMFrames, + hpVgMonGlbDataErrorFrames, + hpVgMonGlbPriorityPromotions, + hpVgMonGlbHCReadableOctets, + hpVgMonGlbHCUnreadableOctets, + hpVgMonGlbHCHighPriorityOctets, + hpVgMonGlbHCNormPriorityOctets, + hpVgMonGlbNormPriorityFrames, + hpVgMonGlbNormPriorityOctets, + hpVgMonGlbNullAddressedFrames, + hpVgMonGlbOversizeFrames, + hpVgMonGlbTransitionToTrainings + } + STATUS current + DESCRIPTION + "HP specific extensions to the 802.12 Repeater MIB + providing global counters for 802.12 repeaters." + ::= { hpicfVgRptrGroups 4 } + + hpicfVgRptrXcvrGroup OBJECT-GROUP + OBJECTS { hpVgXcvrType, + hpVgXcvrAssociatedPort, + hpVgXcvrState, + hpVgXcvrAbandonments, + hpVgXcvrIsMovable, + hpVgPortAssociatedXcvrIndex, + hpVgPortNumAssociatedXcvrs + } + STATUS current + DESCRIPTION + "A collection of objects for configuring and + monitoring tranceivers on 802.12 repeaters." + ::= { hpicfVgRptrGroups 5 } + + hpicfVgRptrRedundantUplinkGroup OBJECT-GROUP + OBJECTS { hpVgRedundantUpLinksFlag } + STATUS current + DESCRIPTION + "A collection of objects for configuring + redundant uplinks on 802.12 repeaters." + ::= { hpicfVgRptrGroups 6 } + + hpicfVgRptrBasicTraps NOTIFICATION-GROUP + NOTIFICATIONS { hpVgLossOfActiveTrap } + STATUS current + DESCRIPTION + "A collection of notifications used to indicate + port status changes on 802.12 repeaters." + ::= { hpicfVgRptrGroups 7 } + + hpicfVgRptrRedundantUplinkTraps NOTIFICATION-GROUP + NOTIFICATIONS { hpVgRedundantUplinkTrap } + STATUS current + DESCRIPTION + "A collection of notifications used to indicate + status changes on the redundant uplinks on + 802.12 repeaters." + ::= { hpicfVgRptrGroups 8 } + + END + |