summaryrefslogtreecommitdiff
path: root/MIBS/extreme/EXTREME-TRAP-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/extreme/EXTREME-TRAP-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/extreme/EXTREME-TRAP-MIB')
-rw-r--r--MIBS/extreme/EXTREME-TRAP-MIB207
1 files changed, 207 insertions, 0 deletions
diff --git a/MIBS/extreme/EXTREME-TRAP-MIB b/MIBS/extreme/EXTREME-TRAP-MIB
new file mode 100644
index 0000000..a97331b
--- /dev/null
+++ b/MIBS/extreme/EXTREME-TRAP-MIB
@@ -0,0 +1,207 @@
+--/*
+-- *
+-- * Copyright (c) 1997 - 2002 by Extreme Networks Inc.
+-- *
+-- * Extreme Networks
+-- * http://www.extremenetworks.com
+-- *
+-- * extracted from $Extreme_Id: extreme.mib,v 1.24.6.35 2006/01/09 15:15:18 build-sc Exp $
+-- *
+-- */
+
+
+-- << end >>
+
+-- ============================================================================
+--
+-- Extreme Traps
+--
+
+EXTREME-TRAP-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ extremenetworks, extremeV1Traps FROM EXTREME-BASE-MIB
+ extremeSlotNumber FROM EXTREME-SYSTEM-MIB
+ extremeSlotModuleConfiguredType FROM EXTREME-SYSTEM-MIB
+ extremeSlotModuleInsertedType FROM EXTREME-SYSTEM-MIB
+ extremeSlotModuleState FROM EXTREME-SYSTEM-MIB
+ extremePowerSupplyNumber, extremeFanNumber
+ FROM EXTREME-SYSTEM-MIB
+ extremeCurrentTemperature FROM EXTREME-SYSTEM-MIB
+ extremeEsrpGroup, extremeEsrpState,
+ extremeEsrpNetAddress FROM EXTREME-ESRP-MIB
+ extremeEsrpActivePorts, extremeEsrpInternalActivePorts
+ FROM EXTREME-ESRP-MIB
+ extremeEsrpTrackedActivePorts, extremeEsrpTrackedIpRoutes
+ FROM EXTREME-ESRP-MIB
+ extremeVlanIfIndex, extremeVlanIfDescr FROM EXTREME-VLAN-MIB
+ extremeEdpPortIfIndex, extremeEdpNeighborId,
+ extremeEdpEntryAge, extremeEdpNeighborVlanName,
+ extremeEdpNeighborVlanIpAddress FROM EXTREME-EDP-MIB
+ sysUpTime, sysDescr, ifPhysAddress,
+ ifDescr FROM RFC1213-MIB
+ ifAlias FROM IF-MIB
+ NOTIFICATION-TYPE FROM SNMPv2-SMI;
+
+ extremeOverheat NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr, extremeCurrentTemperature }
+ STATUS current
+ DESCRIPTION
+ "A overheat trap indicates that the on board
+ tempature sensor has reported a overheat
+ condition. System will shutdown until unit has
+ suficiently cooled such that operation may begin
+ again. A cold start trap will be issued when
+ the unit has come back on line."
+ ::= {extremeV1Traps 6}
+
+ extremeFanfailed NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr, extremeFanNumber }
+ STATUS current
+ DESCRIPTION
+ "A fan failed trap indicates one or more of the
+ cooling fans inside the device has failed. A
+ fanOK trap will be sent once the fan has attained
+ normal operation."
+ ::= {extremeV1Traps 7}
+
+ extremeFanOK NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr, extremeFanNumber }
+ STATUS current
+ DESCRIPTION
+ "A fan has transitioned out of a failure state and
+ is now operating correctly."
+ ::= {extremeV1Traps 8}
+
+ extremeInvalidLoginAttempt NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr }
+ STATUS current
+ DESCRIPTION
+ "A user attempted to login to console or by telnet but was
+ refused access due to incorrect username or password"
+ ::= {extremeV1Traps 9}
+
+ extremePowerSupplyFail NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr, extremePowerSupplyNumber }
+ STATUS current
+ DESCRIPTION
+ "One or more sources of power to this agent has failed.
+ Presumably a redundant power-supply has taken over."
+ ::= {extremeV1Traps 10}
+
+ extremePowerSupplyGood NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr, extremePowerSupplyNumber }
+ STATUS current
+ DESCRIPTION
+ "One or more previously bad sources of power to this agent
+ has come back to life without causing an agent restart."
+ ::= {extremeV1Traps 11}
+
+ extremeRpsAlarm NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr }
+ STATUS current
+ DESCRIPTION
+ "Attached Redundant Power Supply device is indicating
+ an alarm condition."
+ ::= {extremeV1Traps 12}
+
+ extremeRpsNoAlarm NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr }
+ STATUS current
+ DESCRIPTION
+ "Attached Redundant Power Supply device is no longer
+ indicating an alarm condition."
+ ::= {extremeV1Traps 13}
+
+--
+-- SmartTrap definition
+--
+ extremeSmartTrap NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, sysDescr }
+ STATUS current
+ DESCRIPTION
+ "Signifies that the value of one of the object identifiers
+ (or the value of an object below that in the MIB tree)
+ defined in the extremeSmartTrapRulesTable has changed,
+ and hence a new entry has been created in the
+ extremeSmartTrapInstanceTable. Such a trap is sent
+ at most once every thirty seconds if one or more entry
+ was created in the last thirty seconds."
+ ::= {extremeV1Traps 14}
+
+--
+-- Traps for Black Diamond
+--
+ extremeModuleStateChanged NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, extremeSlotNumber,
+ extremeSlotModuleConfiguredType,
+ extremeSlotModuleInsertedType,
+ extremeSlotModuleState }
+ STATUS current
+ DESCRIPTION
+ "Signifies that the value of the extremeSlotModuleState for
+ the specified extremeSlotNumber has changed."
+ ::= {extremeV1Traps 15}
+
+-- extremeModuleOverheat TRAP-TYPE
+-- ENTERPRISE extremenetworks
+-- VARIABLES {sysUpTime, extremeSlotNumber }
+-- DESCRIPTION
+-- "Signifies that the temperature sensor on the module
+-- inside this slot has reported an Overheat condition."
+-- ::= 16
+
+ extremeEsrpStateChange NOTIFICATION-TYPE
+ OBJECTS {sysUpTime, sysDescr, extremeVlanIfIndex,
+ extremeVlanIfDescr, extremeEsrpGroup, extremeEsrpState,
+ extremeEsrpNetAddress, ifPhysAddress,
+ extremeEsrpActivePorts, extremeEsrpInternalActivePorts,
+ extremeEsrpTrackedActivePorts, extremeEsrpTrackedIpRoutes
+ }
+ STATUS current
+ DESCRIPTION
+ "Signifies Esrp state change"
+ ::= {extremeV1Traps 17}
+
+ extremeSlbUnitAdded NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The server load balancer has activated a group of virtual
+ servers that it normally would not activate. This may be
+ due to the failure of another server load balancer."
+
+ ::= {extremeV1Traps 18}
+
+ extremeSlbUnitRemoved NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The server load balancer has deactivated a group of virtual
+ servers that it normally has active. This indicates that
+ something is wrong in the server load balancer; for example,
+ its ping check may be failing."
+ ::= {extremeV1Traps 19}
+
+ extremeEdpNeighborAdded NOTIFICATION-TYPE
+ OBJECTS {sysUpTime, extremeEdpPortIfIndex,
+ extremeEdpNeighborId, extremeEdpEntryAge,
+ ifAlias, ifDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "This node discovers a new neighbor through Extreme Discovery
+ Protocol."
+ ::= {extremeV1Traps 20}
+
+ extremeEdpNeighborRemoved NOTIFICATION-TYPE
+ OBJECTS {sysUpTime, extremeEdpPortIfIndex,
+ extremeEdpNeighborId, extremeEdpEntryAge,
+ ifAlias, ifDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "No EDP updates are received from this neighbor within
+ the configured timeout period and this neighbor entry is aged
+ out by the device."
+ ::= {extremeV1Traps 21}
+
+END