diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-BDG-MIB | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/enterasys/CTRON-BDG-MIB')
| -rw-r--r-- | MIBS/enterasys/CTRON-BDG-MIB | 1677 |
1 files changed, 1677 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-BDG-MIB b/MIBS/enterasys/CTRON-BDG-MIB new file mode 100644 index 0000000..29521a4 --- /dev/null +++ b/MIBS/enterasys/CTRON-BDG-MIB @@ -0,0 +1,1677 @@ +CTRON-BDG-MIB DEFINITIONS ::= BEGIN + + -- ctron-bdg-mib.txt + -- Part Number: 2170561-01 + -- Revision: 1.01.01 + -- Date: June 22, 1996 + + -- Cabletron Systems, Inc. + -- 35 Industrial Way, P.O. Box 5005 + -- Rochester, NH 03867-0505 + -- (603) 332-9400 + -- support@ctron.com + + -- This module provides authoritative definitions for Cabletron's + -- enterprise-specific common MIB. + -- + -- This module will be extended, as required. + -- + + -- Cabletron Systems reserves the right to make changes in + -- specification and other information contained in this document + -- without prior notice. The reader should consult Cabletron Systems + -- to determine whether any such changes have been made. + -- + -- In no event shall Cabletron Systems be liable for any incidental, + -- indirect, special, or consequential damages whatsoever (including + -- but not limited to lost profits) arising out of or related to this + -- document or the information contained in it, even if Cabletron + -- Systems has been advised of, known, or should have known, the + -- possibility of such damages. + -- + -- Cabletron grants vendors, end-users, and other interested parties + -- a non-exclusive license to use this Specification in connection + -- with the management of Cabletron products. + + -- Copyright August 95 Cabletron Systems + + + IMPORTS + OBJECT-TYPE FROM RFC-1212 + bridge, layerMgmt + FROM IRM-OIDS + Counter FROM RFC1155-SMI; + + +bridgeRev1 OBJECT IDENTIFIER ::= { bridge 1 } +bdgdevice OBJECT IDENTIFIER ::= { bridgeRev1 1 } + +bdgPort OBJECT IDENTIFIER ::= { bridgeRev1 2 } + +filterDB OBJECT IDENTIFIER ::= { bridgeRev1 3 } + +trapTypes OBJECT IDENTIFIER ::= { bridgeRev1 4 } + +bdgTables OBJECT IDENTIFIER ::= { bridgeRev1 5 } + +acqDB OBJECT IDENTIFIER ::= { filterDB 1 } + +permDB OBJECT IDENTIFIER ::= { filterDB 2 } + +specialDB OBJECT IDENTIFIER ::= { filterDB 3 } + +acqStats OBJECT IDENTIFIER ::= { acqDB 1 } + +acqOptions OBJECT IDENTIFIER ::= { acqDB 2 } + +permStats OBJECT IDENTIFIER ::= { permDB 1 } + +permOptions OBJECT IDENTIFIER ::= { permDB 2 } + +specStats OBJECT IDENTIFIER ::= { specialDB 1 } + +specFilters OBJECT IDENTIFIER ::= { specialDB 2 } + + +-- Device Object Definitions +-- +-- This section defines the objects under the Device node. +-- +-- Instance Identifiers for Device Objects +-- +-- There is only one instance of a Device object, thus the Instance +-- Identifier is 0. +-- +-- Device Objects + + +bdgdeviceDisableBdg OBJECT-TYPE +SYNTAX INTEGER + { + disableBridge (0), + enableBridge (1) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Indicates if the bridge will be disabled." +::= { bdgdevice 1 } + + +bdgdeviceRestoreSettings OBJECT-TYPE +SYNTAX INTEGER + { + restoreSettings (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Restore the following settings to their default values: + Bridge Name to ETHERNET_BRIDGE, + Location to LOCAL, + Port 1 Name to PORT_1, + Port 2 Name to PORT_2, + Port 1 Network Name to LAN_1, + Port 2 Network Name to LAN_2, + Ageing Time for Acquired Database to 300 seconds, + Erase the acquired database, + Erase the permanent database, + Place sixteen default multicast addresses into + the permanent and acquired databases, + Type of Spanning Tree to 802.1, + Type of Filtering to IEEE 802.1, + Bridge Max Age to 20 seconds, + Bridge Forward Delay to 15 seconds, + Bridge Hello Time to 2 seconds, + Bridge Priority to 8000, + Port 1 Priority to 80, + Port 2 Priority to 80, + Port 1 Path Cost to 100, + Port 2 Path Cost to 100, + Restart the bridge." +::= { bdgdevice 2 } + + +bdgdeviceBdgName OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The user-defined name (up to 32 characters long) of the bridge. + The default bridge name is ETHERNET_BRIDGE." +::= { bdgdevice 4 } + + +bdgdeviceNumPorts OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of ports present on the bridge." +::= { bdgdevice 5 } + + +bdgdeviceType OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The type of bridge, NB25E, IRBM, or NB20E." +::= { bdgdevice 6 } + + +bdgdeviceVersion OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The release version of the firmware installed in the bridge." +::= { bdgdevice 7 } + + +bdgdeviceLocation OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The user-defined name to indicate the location of the bridge on + the network. The default location name is LOCAL." +::= { bdgdevice 8 } + + +bdgdeviceStatus OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The status of the bridge, ON-LINE, STAND BY or DISABLED." +::= { bdgdevice 9 } + + +bdgdeviceRestartBdg OBJECT-TYPE +SYNTAX INTEGER + { + restartBridge (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Force the bridge to undergo a software reset." +::= { bdgdevice 10 } + + +bdgdeviceFrFwd OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames forwarded by the bridge." +::= { bdgdevice 11 } + + +bdgdeviceFrRx OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames received by the bridge." +::= { bdgdevice 12 } + + +bdgdeviceFrFlt OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames filtered by the bridge." +::= { bdgdevice 13 } + + +bdgdeviceErr OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The total number of network errors that have occurred." +::= { bdgdevice 14 } + + +bdgdeviceSwitchSetting OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Indicates the current switch settings read from the bridge + hardware." +::= { bdgdevice 15 } + + +bdgdeviceNumRestarts OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of times the bridge has been powered up or restarted." +::= { bdgdevice 16 } + + +bdgdeviceTypeFiltering OBJECT-TYPE +SYNTAX INTEGER + { + ieee8021 (0), + specialDB (1), + both (2) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The type of filtering to be performed by the bridge. The default + is IEEE 802.1." +::= { bdgdevice 17 } + + +bdgdeviceSTAProtocol OBJECT-TYPE +SYNTAX INTEGER + { + ieee8021 (0), + dec (1), + none (2) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The spanning tree algorithm under which the bridge is operating. + The selections are as follows: + - IEEE 802.1 compliant spanning tree algorithm + environment (802.1) + - DEC LAN Bridge 100 environment (DEC) + - Without the spanning tree algorithm enabled (NONE) + The default is 802.1." +::= { bdgdevice 18 } + + +bdgdeviceBridgeID OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The unique identifier of the bridge. The first two bytes of the + identifier are the bridge priority and the last six bytes are the + Ethernet address." +::= { bdgdevice 19 } + + +bdgdeviceTopChgCnt OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of times the bridge's Topology Change Flag has been + changed since the bridge was powered up or initialized." +::= { bdgdevice 20 } + + +bdgdeviceRootCost OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The cost of the path to the root from this bridge." +::= { bdgdevice 21 } + + +bdgdeviceRootPort OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The port identifier for the port which offers the lowest cost + path to the root, i.e. that port for which the sum of the values + of the designated cost and path cost parameters held for the port + is lowest." +::= { bdgdevice 22 } + + +bdgdeviceHelloTime OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The time interval between the transmission of Configuration + BPDU's by a bridge which is attempting to become the root or is + the root." +::= { bdgdevice 23 } + + +bdgdeviceBdgMaxAge OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The value of the Max Age parameter when the bridge is the root + or is attempting to become the root. A time of 6 to 40 seconds is + allowed. The default is 20 seconds." +::= { bdgdevice 24 } + + +bdgdeviceBdgFwdDly OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The value of the forward delay parameter when the bridge is the + root or is attempting to become the root. A time of 4 to 30 + seconds is allowed." +::= { bdgdevice 25 } + + +bdgdeviceTimeTopChg OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The time in seconds that has elapsed since the bridge's Topology + Change Flag last recorded the value of a topology change." +::= { bdgdevice 26 } + + +bdgdeviceTopChg OBJECT-TYPE +SYNTAX INTEGER +{ + noTopologyChangeInProgress (0), + topologyChangeInProgress (1) +} +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Indicates if a bridge topology change is in progress." +::= { bdgdevice 27 } + + +bdgdeviceDesigRoot OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The unique identifier of the bridge recorded as the root." +::= { bdgdevice 28 } + + +bdgdeviceMaxAge OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The maximum age of received protocol information before it is + discarded." +::= { bdgdevice 29 } + + +bdgdeviceHoldTime OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The minimum time period elapsing between the transmission of + configuration BPDU's through a given bridge port." +::= { bdgdevice 30 } + + +bdgdeviceFwdDly OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The time spent in the listening state while moving from the + blocking state to the learning state, or the time spent in the + learning state while moving from the listening state to the + forwarding state." +::= { bdgdevice 31 } + + +bdgdeviceBdgHello OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The value of the Hello Time parameter when the bridge is the + root or is attempting to become the root. A time of 1 to 10 + seconds is allowed. The default is 2 seconds." +::= { bdgdevice 32 } + + +bdgdeviceBdgPriority OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The part of the bridge address that contains the identifier used + in the spanning tree for priority comparisons. Allowed range is 0 + through FFFF. The default is 8000." +::= { bdgdevice 33 } + + +bdgdeviceResetCounts OBJECT-TYPE +SYNTAX INTEGER + { + resetCounts (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Reset all counters to zero." +::= { bdgdevice 34 } + + +bdgdeviceUptime OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The time, in seconds, that has elapsed since the bridge was last + reset or initialized." +::= { bdgdevice 35 } + + +bdgdeviceTrapType OBJECT-TYPE +SYNTAX OBJECT IDENTIFIER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Contains the object identifier of the first VarBinding in the + last trap generated by the bridge." +::= { bdgdevice 36 } + + +-- Port Object Definitions +-- +-- This section defines the objects under the Port node. +-- +-- Instance Identifiers for Port Objects +-- +-- The Instance Identifier for port objects is the number of the port on +-- the bridge. Valid instance identifiers for the ports on the IRBM, +-- NB25E, and NB20E bridges are 1 and 2. +-- +-- Port Objects + + +bdgPortAddress OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The Ethernet address of the port." +::= { bdgPort 1 } + +bdgPortName OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The user-defined name assigned to the port. The default port 1 + name is PORT_1 and the default Port 2 name is PORT_2." +::= { bdgPort 2 } + +bdgPortType OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The IEEE specification the port meets, e.g. 802.3." +::= { bdgPort 3 } + +bdgPortStatus OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The status in which the port is operating. The status messages + for Ports 1 and 2 are: + + OFF - The port is off, due to a failed network interface + chip associated with that port. + + OK/SQE ON - The port is communicating with the network + and the transceiver making the connection to the network + has SQE enabled. + + OK/SQE OFF - The port is communicating with the network + and the transceiver making the connection to the network + has SQE disabled. + + CARRIER LOST - Communication with the network has not + been established or has been lost." +::= { bdgPort 4 } + +bdgPortNetName OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The user-defined name assigned to a network segment connected to + the port. The default network name for Port 1 is LAN_1 and the + default network name for Port 2 is LAN_2." +::= { bdgPort 5 } + +bdgPortFrRx OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames received at the specified port." +::= { bdgPort 6 } + +bdgPortDisInb OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The total number of valid frames that were received at the port + but then discarded by the bridge in the forwarding process." +::= { bdgPort 7 } + +bdgPortFwdOutb OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames forwarded successfully to the appropriate + port." +::= { bdgPort 8 } + +bdgPortDisLOB OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets that were discarded by the bridge because + of a lack of buffer space to maintain the data." +::= { bdgPort 9 } + +bdgPortDisTDE OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames that were intended for forwarding but were + discarded when the maximum time period set for transmission was + exceeded before forwarding was possible." +::= { bdgPort 10 } + +bdgPortDisErr OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames that could not be transmitted because the + frame was too large for the attached network (1526 bytes, + including preamble, for 802.3 networks)." +::= { bdgPort 11 } + +bdgPortColl OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of collisions that have occurred on the network at + the specified port." +::= { bdgPort 12 } + +bdgPortTxAbrt OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmissions that have been aborted due to + excessive collisions (over 16 attempts to transmit the same + packet)." +::= { bdgPort 13 } + +bdgPortOowColl OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of collisions out of the standard collision window + (51.2 uS). This indicates a network problem." +::= { bdgPort 14 } + +bdgPortCRCErr OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets detected with Cyclical Redundancy Check + failures." +::= { bdgPort 15 } + +bdgPortFrAlErr OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of errors due to misaligned packets." +::= { bdgPort 16 } + +bdgPortPriority OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The part of the port identifier which is used with the spanning + tree algorithm when determining which port in a LAN segment has + priority. The default is 80." +::= { bdgPort 17 } + +bdgPortState OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The current state of the port, DISABLED, LISTENING, LEARNING, + FORWARDING or BLOCKING." +::= { bdgPort 18 } + +bdgPortPathCost OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The contributory cost of the applicable port to the overall cost + of the path when the specified port is the root port. Allowable + range is 1 to 65535. The default is 100." +::= { bdgPort 19 } + +bdgPortDesigCost OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The cost of the path of this port to the root bridge on the + network." +::= { bdgPort 20 } + +bdgPortDesigBrdg OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The network address of the bridge that is assumed to be the root + bridge on the network." +::= { bdgPort 21 } + +bdgPortDesigPort OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The port identifier of the bridge port believed to be the + designated port for the LAN associated with the port." +::= { bdgPort 22 } + +bdgPortTopChgAck OBJECT-TYPE +SYNTAX INTEGER + { + noTopologyChangeIsOccurring (0), + topologyChangeIsOccurring (1) + } +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The value of the topology change acknowledgement flag in the + next configuration BPDU to be transmitted on the associated port." +::= { bdgPort 23 } + +bdgPortDesigRoot OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The unique bridge identifier of the bridge that is assumed to be + the root bridge on the network." +::= { bdgPort 24 } + +bdgPortRuntPackets OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets received at the indicated bdgPort that were + less than the IEEE 802.3 minimum Ethernet frame size of 64 bytes." +::= { bdgPort 25 } + +bdgPortOversizePackets OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets received at the indicated port that were + greater than the IEEE 802.3 maximum Ethernet frame size of 1518 + bytes." +::= { bdgPort 26 } + +bdgPortFrFilt OBJECT-TYPE +SYNTAX Counter +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames received at the indicated port that were + filtered by the bridge." +::= { bdgPort 27 } + + +-- Acquired Database Statistical Object Definitions +-- +-- This section defines the objects under the Acquired Database +-- Statistics node. +-- +-- Instance Identifiers for Acquired Database Statistical Objects +-- +-- There is only one instance of an Acquired Database Statistical object, +-- thus the Instance Identifier is 0. +-- +-- Acquired Database Statistical Objects + + +acqTotalEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The total number of entries in the acquired database." +::= { acqStats 1 } + +acqMaxEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The maximum number of entries allowed in the acquired database." +::= { acqStats 2 } + +acqStaticEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of addresses added to the Acquired database by the + user or network manager." +::= { acqStats 3 } + +acqStaticAgeTime OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The length of time allowed for a static entry in the Acquired + database to be inactive before it is dropped from the database. + This time is fixed at zero." +::= { acqStats 4 } + +acqDynEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of entries that have been accumulated in the Acquired + database through the bridge's learning process." +::= { acqStats 5 } + +acqDynAgeTime OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-write +STATUS mandatory +DESCRIPTION + "The length of time allowed for a dynamic entry in the acquired + database to be inactive before it is dropped from the database. A + time from 10 - 1,000,000 seconds is allowed. The default is 300 + seconds." +::= { acqStats 6 } + +acqEraseDatabase OBJECT-TYPE +SYNTAX INTEGER + { + eraseAcquiredDatabase (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set to zero to erase all entries in the acquired database." +::= { acqStats 7 } + + +-- Acquired Database Option Object Definitions +-- +-- This section defines the objects under the Acquired Database +-- Option node. +-- +-- Instance Identifiers for Acquired Database Option Objects +-- +-- The instance identifier for the acquired database option objects is +-- the 6-byte Ethernet address of the device to be added, deleted or +-- displayed to/from the acquired database. +-- +-- Acquired Database Option Objects + + +acqCreate00 OBJECT-TYPE +SYNTAX INTEGER + { + createAcquiredEntryFilterPort1FilterPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the acquired database to filter packets entering + ports 1 and 2 if those packets are destined for the specified + address." +::= { acqOptions 1 } + +acqCreate20 OBJECT-TYPE +SYNTAX INTEGER + { + createAcquiredEntryForwardPort1FilterPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the acquired database to forward packets + entering port1 to port2 and filter packets entering port2 if + those packets are destined for the specified address." +::= { acqOptions 2 } + +acqCreate01 OBJECT-TYPE +SYNTAX INTEGER + { + createAcquiredEntryFilterPort1ForwardPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the acquired database to filter packets entering + port 1 and forward packets entering port 2 to port 1 if those + packets are destined for the specified address." +::= { acqOptions 3 } + +acqCreate21 OBJECT-TYPE +SYNTAX INTEGER + { + createAcquiredEntryForwardPort1ForwardPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the acquired database to forward packets + entering port 1 to port 2 and to forward packets entering port 2 + to port 1 if those packets are destined for the specified + address." +::= { acqOptions 4 } + +acqDelete OBJECT-TYPE +SYNTAX INTEGER + { + deleteAcquiredEntry (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Delete an entry from the acquired database." +::= { acqOptions 5 } + +acqDispType OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Display the entry type, STATIC or DYNAMIC." +::= { acqOptions 6 } + +acqDispOutp1 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (2) + } +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The outbound port for packets entering port 1." +::= { acqOptions 7 } + +acqDispOutp2 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (1) + } +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The outbound port for packets entering port 2." +::= { acqOptions 8 } + +acqSrcAddress OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The source address of this acquired database entry, i.e. the + instance." +::= { acqOptions 9 } + +-- Permanent Database Statistical Object Definitions +-- +-- This section defines the objects under the Permanent Database +-- Statistics node. +-- +-- Instance Identifiers for Permanent Database Statistical Objects +-- +-- There is only one instance of an Permanent Database Statistical +-- object, thus the Instance Identifier is 0. +-- +-- Permanent Database Statistical Objects + + +permMaxEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The maximum number of entries allowed in the permanent database." +::= { permStats 1 } + +permCurrEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of entries currently recorded in the bridge's + permanent database." +::= { permStats 2 } + +permEraseDatabase OBJECT-TYPE +SYNTAX INTEGER + { + erasePermanentDatabase (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Erase all entries in the permanent database." +::= { permStats 3 } + +-- Permanent Database Option Object Definitions +-- +-- This section defines the objects under the Permanent Database +-- Option node. +-- +-- Instance Identifiers for Permanent Database Option Objects +-- +-- The instance identifier for the permanent database option objects is +-- the 6-byte Ethernet address of the device to be added, deleted or +-- displayed to/from the permanent database. +-- +-- Permanent Database Option Objects + +permCreate00 OBJECT-TYPE +SYNTAX INTEGER + { + createPermanentEntryFilterPort1FilterPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the permanent database to filter packets + entering ports 1 and 2 if those packets are destined for the + specified address." +::= { permOptions 1 } + +permCreate20 OBJECT-TYPE +SYNTAX INTEGER + { + createPermanentEntryForwardPort1FilterPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the permanent database to forward packets + entering port 1 and filter packets entering port 2 if those + packets are destined for the specified address." +::= { permOptions 2 } + +permCreate01 OBJECT-TYPE +SYNTAX INTEGER + { + createPermanentEntryFilterPort1ForwardPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the permanent database to filter packets + entering port 1 and forward packets entering port 2 if those + packets are destined for the specified address." +::= { permOptions 3 } + +permCreate21 OBJECT-TYPE +SYNTAX INTEGER + { + createPermanentEntryForwardPort1ForwardPort2 (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Add an entry to the permanent database to forward packets + entering ports 1 and 2 if those packets are destined for the + specified address." +::= { permOptions 4 } + +permDelete OBJECT-TYPE +SYNTAX INTEGER + { + deletePermanentEntry (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Delete an entry from the permanent database." +::= { permOptions 5 } + +permDispType OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Display the entry type, STATIC or DYNAMIC." +::= { permOptions 6 } + +permDispOutp1 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (2) + } +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The outbound port for packets entering port 1." +::= { permOptions 7 } + +permDispOutp2 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (1) + } +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The outbound port for packets entering port 2." +::= { permOptions 8 } + +permSrcAddress OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The source address in this permanent database entry, i.e. the + instance." +::= { permOptions 9 } + +-- Special Database Statistical Object Definitions +-- +-- This section defines the objects under the Special Database +-- Statistical node. +-- +-- Instance Identifiers for Special Database Statistical Objects +-- +-- There is only one instance of a Special Database Statistical object, +-- thus the Instance Identifier is 0. +-- +-- Special Database Statistical Objects + +specNumEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of filters in the special database." +::= { specStats 1 } + +specMaxEntries OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The maximum number of filters the special database can contain." +::= { specStats 2 } + +specNextFilterNum OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of the next available filter that can be added to the + special database." +::= { specStats 3 } + +-- Special Database Filter Object Definitions +-- +-- This section defines the objects under the Special Database +-- Filter node. +-- +-- Instance Identifiers for Special Database Filter Objects +-- +-- The instance identifier of the special database filter objects +-- is the filter number, values from 1 through 10 are allowed. +-- +-- Special Database Filter Objects + +specEnable OBJECT-TYPE +SYNTAX INTEGER + { + disableFilter (0), + enableFilter (1) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Enable or disable the filter." +::= { specFilters 1 } + +specPort1 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (2) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set port 1 to filter or forward packets." +::= { specFilters 2 } + +specPort2 OBJECT-TYPE +SYNTAX INTEGER + { + filter (0), + relay (1) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set port 2 to filter or forward packets." +::= { specFilters 3 } + +specDestAddress OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set the special database to filter packets with a specific + destination address." +::= { specFilters 4 } + +specSrcAddress OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set the special database to filter packets with a specific + source address." +::= { specFilters 5 } + +specType OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set the special database to filter packets with a specific type + field." +::= { specFilters 6 } + +specDataField OBJECT-TYPE +SYNTAX OCTET STRING +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Set the special database to filter packets based on the first + sixteen bytes of data in the packet." +::= { specFilters 7 } + +specDeleteFilter OBJECT-TYPE +SYNTAX INTEGER + { + deleteFilter (0) + } +ACCESS read-write +STATUS mandatory +DESCRIPTION + "Delete a filter from the special database." +::= { specFilters 8 } + + +-- TRAP TYPES OBJECT DEFINITIONS +-- +-- This section describes the trap types that the bridge can generate. These +-- are not objects, but Object Identifiers used to indicate the specific trap. +-- They are taken from the object space and are thus documented here. +-- +-- The SNMP trap messages are composed of two user definable areas: +-- a) the specific trap type and +-- b) the VarBindings (e.g. the interesting information) +-- +-- The specific trap type is an integer that is used to determine the +-- specific trap which has occurred. The "interesting information" contains +-- a group of object identifiers and their values that provide information +-- about the trap. +-- +-- Trap Decription +-- +-- BridgeStatus +-- +-- Specific Trap Type Code - 0x0301 +-- +-- When the bridge status changes, a trap will be generated. The +-- interesting information includes the current status of the bridge. +-- +-- +-- Trap Description +-- +-- AcqDbaseFull +-- +-- Specific Trap Type Code - 0x0302 +-- +-- When the acquired portion of the bridge's filtering database is full, a +-- trap is generated. The interesting information included with this trap +-- is the number of entries in the acquired database. + +-- Formal definition of the Layer Management MIB. (e.g. PC cards ) + + lmcommon OBJECT IDENTIFIER ::= { layerMgmt 1 } + + mAC OBJECT IDENTIFIER ::= { layerMgmt 2 } + + ieee8023 OBJECT IDENTIFIER ::= { mAC 1 } + + pcIF OBJECT IDENTIFIER ::= { ieee8023 1 } + + pcIfRev OBJECT IDENTIFIER ::= { pcIF 1 } + + + +pcDeviceName OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "Name of the PC device" +::= { pcIfRev 1 } + + +pcBoardType OBJECT-TYPE + +SYNTAX OBJECT IDENTIFIER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "An object Identifier that indicates the type of the PC + board. This will include MAC type and Media type." + + +::= { pcIfRev 2 } + +pcOwnerName OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The owner of this PC." + + +::= { pcIfRev 3 } + +pcLocation OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "A text description of the location of this PC." + +::= { pcIfRev 4 } + +pcMMACAddr OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The MAC address of the MMAC that this PC is connected to." + + +::= { pcIfRev 5 } + +pcMMACBoard OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The slot number of the board in the MMAC that this PC is +connected to." + + +::= { pcIfRev 6 } + +pcMMACPort OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of the port on the board of the MMAC that this +PC is connected to." +::= { pcIfRev 7 } + +pcApplication OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "A text description of the network application running on +this PC." + + +::= { pcIfRev 8 } + +pcDriverRev OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The revision of the LAN card driver." +::= { pcIfRev 9 } + +pcOnboardMemory OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of Kilobytes of memory (eg. a 16K board would +reply 16)" + +::= { pcIfRev 10 } + +pcComment OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "A user-defined character string." + + +::= { pcIfRev 11 } + +pcMACAddr OBJECT-TYPE + +SYNTAX OCTET STRING +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The MAC address of the PC card." + + +::= { pcIfRev 12 } + +pcFramesXmit OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of MAC frames transmitted by this PC card." + + +::= { pcIfRev 13 } + +pcBytesXmit OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number bytes transmitted by this PC card." + + +::= { pcIfRev 14 } + +pcMcastXmit OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of multicasted frames sent by this PC card." + +::= { pcIfRev 15 } + +pcBcastXmit OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of broadcast frames from this PC card." + + +::= { pcIfRev 16 } + +pcDeferXmit OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packets that were deferred due to +busy media." + +::= { pcIfRev 17 } + +pcSglColl OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packet experiencing a single +collision." + +::= { pcIfRev 18 } + +pcMultiColl OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packets that have experienced +multiple collisions." + +::= { pcIfRev 19 } + +pcTotXmitErrs OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The total number of transmit errors." + +::= { pcIfRev 20 } + +pcLateColls OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packets that experienced late +collisions." + + +::= { pcIfRev 21 } + +pcXcessColls OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packets aborted due to excess +collisions." + +::= { pcIfRev 22 } + +pcCarrErr OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of transmit packets that experience carrier +sense errors (ie. lose carrier during transmission)." + +::= { pcIfRev 23 } + +pcFramesRec OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of frames received." + +::= { pcIfRev 24 } + +pcBytesRec OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of bytes received by this station." + + +::= { pcIfRev 25 } + +pcMcastRec OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of multicasted frames received." + +::= { pcIfRev 26 } + +pcBcastRec OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of broadcast packets received." + +::= { pcIfRev 27 } + +pcTotRecErrs OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The total number of receive errors." + +::= { pcIfRev 28 } + +pcTooLong OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets received that are too long (over 1518 +bytes)." + +::= { pcIfRev 29 } + +pcTooShort OBJECT-TYPE +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets that are too short. (under 64 bytes +long)." + +::= { pcIfRev 30 } + +pcAlignErrs OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of alignment errors in receive packets." + + +::= { pcIfRev 31 } + +pcCRCErrs OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of receive packets with CRC errors." + +::= { pcIfRev 32 } + +pcLenErrs OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of packets whose length is not equal to the +number of bytes received." + +::= { pcIfRev 33 } + +pcIntRecErr OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of receive packets that experienced internal +errors (eg. no receive buffers)." + +::= { pcIfRev 34 } + +pcSqeErr OBJECT-TYPE + +SYNTAX INTEGER +ACCESS read-only +STATUS mandatory +DESCRIPTION + "The number of SQE errors." + +::= { pcIfRev 35 } + +END |