summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-APPN-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/enterasys/CTRON-APPN-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/enterasys/CTRON-APPN-MIB')
-rw-r--r--MIBS/enterasys/CTRON-APPN-MIB3213
1 files changed, 3213 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTRON-APPN-MIB b/MIBS/enterasys/CTRON-APPN-MIB
new file mode 100644
index 0000000..76765ac
--- /dev/null
+++ b/MIBS/enterasys/CTRON-APPN-MIB
@@ -0,0 +1,3213 @@
+CTRON-APPN-MIB DEFINITIONS ::= BEGIN
+
+-- ctron-appn-mib.txt
+-- Revision: 1.00.03
+-- Part Number: 2171066
+-- Date: June 20, 1996
+
+-- Cabletron Systems, Inc.
+-- 35 Industrial Way, P.O. Box 5005
+-- Rochester, NH 03867-0505
+-- (603) 332-9400
+-- support@ctron.com
+
+-- This module provides authoritative definitions for Cabletron's
+-- enterprise specific APPN Routing Services MIB.
+--
+--
+-- This module will be extended as required.
+--
+-- Cabletron Systems reserves the right to make changes in
+-- specification and other information contained in this document
+-- without prior notice. The reader should consult Cabletron Systems
+-- to determine whether any such changes have been made.
+--
+-- In no event shall Cabletron Systems be liable for any incidental,
+-- indirect, special, or consequential damages whatsoever (including
+-- but not limited to lost profits) arising out of or related to this
+-- document or the information contained in it, even if Cabletron
+-- Systems has been advised of, known, or should have known, the
+-- possibility of such damages.
+--
+-- Cabletron grants vendors, end-users, and other interested parties
+-- a non-exclusive license to use this Specification in connection
+-- with the management of Cabletron products.
+
+
+-- Copyright August 95 Cabletron Systems
+
+
+IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+ nwRtrProtoSuites
+ FROM ROUTER-OIDS
+ DisplayString
+ FROM RFC1213-MIB
+ Counter, TimeTicks
+ FROM RFC1155-SMI;
+
+-- The APPN Router Group.
+
+nwAppnRouter OBJECT IDENTIFIER ::= { nwRtrProtoSuites 5 }
+
+nwAppnMibs OBJECT IDENTIFIER ::= { nwAppnRouter 1 }
+nwAppnComponents OBJECT IDENTIFIER ::= { nwAppnRouter 2 }
+
+-- APPN Router Component Groups
+
+nwAppnSystem OBJECT IDENTIFIER ::= { nwAppnComponents 1 }
+nwAppnForwarding OBJECT IDENTIFIER ::= { nwAppnComponents 2 }
+nwAppnTopology OBJECT IDENTIFIER ::= { nwAppnComponents 4 }
+nwAppnFib OBJECT IDENTIFIER ::= { nwAppnComponents 5 }
+nwAppnEndSystems OBJECT IDENTIFIER ::= { nwAppnComponents 6 }
+nwAppnAccessControl OBJECT IDENTIFIER ::= { nwAppnComponents 7 }
+nwAppnFilters OBJECT IDENTIFIER ::= { nwAppnComponents 8 }
+nwAppnRedirector OBJECT IDENTIFIER ::= { nwAppnComponents 9 }
+nwAppnEvent OBJECT IDENTIFIER ::= { nwAppnComponents 10 }
+nwAppnWorkGroup OBJECT IDENTIFIER ::= { nwAppnComponents 11 }
+
+
+-- APPN Router System Groups
+
+nwAppnSysConfig OBJECT IDENTIFIER ::= { nwAppnSystem 1 }
+nwAppnSysAdministration OBJECT IDENTIFIER ::= { nwAppnSystem 2 }
+
+-- APPN Router System Configuration Groups
+
+nwAppnSysCfgLocalNode OBJECT IDENTIFIER ::= { nwAppnSysConfig 2 }
+nwAppnSysCfgTables OBJECT IDENTIFIER ::= { nwAppnSysConfig 3 }
+
+-- APPN Router Forwarding Groups
+
+nwAppnFwdSystem OBJECT IDENTIFIER ::= { nwAppnForwarding 1 }
+nwAppnFwdInterfaces OBJECT IDENTIFIER ::= { nwAppnForwarding 2 }
+nwAppnFwdLinks OBJECT IDENTIFIER ::= { nwAppnForwarding 3 }
+
+nwAppnFwdCounters OBJECT IDENTIFIER ::= { nwAppnFwdSystem 1 }
+nwAppnFwdIfConfig OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 1 }
+nwAppnIfCn OBJECT IDENTIFIER ::= { nwAppnFwdIfConfig 3 }
+nwAppnFwdIfCounters OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 2 }
+nwAppnFwdLsConfig OBJECT IDENTIFIER ::= { nwAppnFwdLinks 1 }
+nwAppnFwdLsCounters OBJECT IDENTIFIER ::= { nwAppnFwdLinks 2 }
+
+
+-- APPN Router Routing Groups
+
+nwAppnDistanceVector OBJECT IDENTIFIER ::= { nwAppnTopology 1 }
+nwAppnLinkState OBJECT IDENTIFIER ::= { nwAppnTopology 2 }
+
+nwAppnIsr OBJECT IDENTIFIER ::= { nwAppnLinkState 1 }
+
+nwAppnIsrSystem OBJECT IDENTIFIER ::= { nwAppnIsr 1 }
+nwAppnIsrInterfaces OBJECT IDENTIFIER ::= { nwAppnIsr 2 }
+nwAppnIsrDatabase OBJECT IDENTIFIER ::= { nwAppnIsr 3 }
+nwAppnIsrFilters OBJECT IDENTIFIER ::= { nwAppnIsr 4 }
+
+nwAppnIsrConfig OBJECT IDENTIFIER ::= { nwAppnIsrSystem 1 }
+nwAppnIsrCounters OBJECT IDENTIFIER ::= { nwAppnIsrSystem 2 }
+
+nwAppnIsrIfConfig OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 1 }
+nwAppnIsrIfCounters OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 2 }
+
+-- APPN Router Host End Systems Groups ( NOT USED )
+
+nwAppnHostsSystem OBJECT IDENTIFIER ::= { nwAppnEndSystems 1 }
+nwAppnHostsInterfaces OBJECT IDENTIFIER ::= { nwAppnEndSystems 2 }
+
+
+-- APPN Router Event Log Group
+
+nwAppnEventLogConfig OBJECT IDENTIFIER ::= { nwAppnEvent 1 }
+nwAppnEventLogFilterTable OBJECT IDENTIFIER ::= { nwAppnEvent 2 }
+nwAppnEventLogTable OBJECT IDENTIFIER ::= { nwAppnEvent 3 }
+
+
+
+
+-- APPN MIB Group
+-- This group contains information about the revision level of this
+-- MIB within the device. It allows verification of the released
+-- version without having to read other objects.
+
+nwAppnMibRevText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current revision level of the Cabletron APPN
+ Router MIB in textual format."
+ ::= { nwAppnMibs 1 }
+
+
+-- APPN Routing Services System Group
+-- This group contains the objects related to APPN Routing Services at a
+-- global system-wide level.
+
+-- APPN Routing Services System Configuration Group
+-- This group contains the objects that pertain to the setup and
+-- configuration of APPN Routing Services at a global,
+-- system-wide level.
+
+nwAppnSysRouterId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3..17))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the APPN Fully-Qualified Control Point name that is used
+ to uniquely identify APPN Routing Services in an APPN network. The
+ name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network
+ identifier and CCCCCCCC is the Control Point name. Valid characters
+ to make up these two strings are uppercase letters A through Z,
+ numerics 0 through 9, and the special characters $, @, and #. The
+ first character of the string must NOT be numeric. Each string must
+ be a maximum length of 8 characters with no embedded spaces and the
+ strings are joined by a dot. nwAppnSysRouterId cannot be modified
+ while APPN routing services is in any operational state other than
+ DISABLED as reflected in nwAppnSysOperStatus. Otherwise, the
+ request will be rejected."
+ ::= { nwAppnSysConfig 1 }
+
+
+
+-- APPN Routing Services System Group
+-- This group contains the objects related to initializing APPN Routing Services
+-- at a global, system-wide level.
+-- All parameters (except for Stop Type) cannot be modified unless the
+-- operational state is disabled. Otherwise, the request will be rejected.
+
+nwAppnSysNodeType OBJECT-TYPE
+ SYNTAX INTEGER {
+ networknode(1)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the node type supported by APPN Routing Services which
+ is always of type Network Node. "
+ DEFVAL { networknode }
+ ::= { nwAppnSysCfgLocalNode 1 }
+
+nwAppnSysCpAlias OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the Control Point alias name used by APPN Routing
+ Services. "
+ ::= { nwAppnSysCfgLocalNode 2 }
+
+nwAppnSysModeCosMap OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether mode to COS mapping is supported by
+ APPN Routing Services."
+ DEFVAL { yes }
+ ::= { nwAppnSysCfgLocalNode 3 }
+
+nwAppnSysMdsSupport OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether Management Services supports Multiple
+ Domain Support and Management Services capabilities. "
+ DEFVAL { yes }
+ ::= { nwAppnSysCfgLocalNode 4 }
+
+nwAppnSysMaxLocates OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum Number of locate requests that APPN Routing
+ Services can concurrently process. Note: if nwAppnSysMaxLocates is
+ set to a value too small, it will be internally increased to a
+ higher value after APPN Routing Services has been successfully
+ enabled. A subsequent GET operation on nwAppnSysMaxLocates will
+ reflect this new value."
+ DEFVAL { 10 }
+ ::= { nwAppnSysCfgLocalNode 6 }
+
+nwAppnSysDirCacheSize OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies number of located resources maintained in the Directory
+ Cache. Note: if nwAppnSysDirCacheSize is set to a value too small,
+ it will be internally increased to a higher value after APPN routing
+ services has been successfully enabled. A subsequent GET
+ operation on nwAppnSysDirCacheSize will reflect this new value. "
+ DEFVAL { 255 }
+ ::= { nwAppnSysCfgLocalNode 7 }
+
+nwAppnSysMaxDirEntries OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum number of directory entries. If zero is selected,
+ the number of entries is unlimited. "
+ DEFVAL { 0 }
+ ::= { nwAppnSysCfgLocalNode 8}
+
+nwAppnSysLocateTimeout OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies time in seconds before a network search will timeout. Zero
+ indicates that the search has no timeout."
+ DEFVAL { 0 }
+ ::= { nwAppnSysCfgLocalNode 9 }
+
+nwAppnSysRegCds OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether the local or domain resources can be registered
+ with the Central Directory Server."
+ DEFVAL { yes }
+ ::= { nwAppnSysCfgLocalNode 10 }
+
+nwAppnSysMdsSendQSize OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies size of the MDS send alert Queue."
+ DEFVAL { 100 }
+ ::= { nwAppnSysCfgLocalNode 11 }
+
+nwAppnSysCosSize OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum number of COS definitions maintained in the COS
+ database weights cache. It determines the size of the COS Database
+ weights cache. Note: if nwAppnSysCosSize is set to a value too
+ small, it will be internally increased to a higher value after
+ APPN Routing Services has been successfully enabled. A subsequent
+ GET operation on nwAppnSysCosSize will reflect this new value. "
+ DEFVAL { 16 }
+ ::= { nwAppnSysCfgLocalNode 12 }
+
+nwAppnSysTreeSize OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the number of routes maintained in the Topology Database
+ routing tree cache. Note: if nwAppnSysTreeSize is set to a value
+ too small, it will be internally increased to a higher value after
+ APPN Routing Services has been successfully enabled. A subsequent
+ GET operation on nwAppnSysTreeSize will reflect this new value. "
+ DEFVAL { 40 }
+ ::= { nwAppnSysCfgLocalNode 13 }
+
+nwAppnSysTreeUseLimit OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum number of times a cached tree will be used to compute a
+ route before the tree is discarded and recomputed. This
+ allows the APPN Routing Services to balance sessions among
+ equal weight routes. A low value provides better load balancing
+ at the expense of increased activation latency. "
+ DEFVAL { 40 }
+ ::= { nwAppnSysCfgLocalNode 14 }
+
+nwAppnSysMaxTdmNodes OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum number of nodes that can be stored in the Topology
+ Database. Zero means unlimited. "
+ DEFVAL { 0 }
+ ::= { nwAppnSysCfgLocalNode 15 }
+
+nwAppnSysMaxTdmTGs OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum number of transmission groups that can be stored in
+ Topology Database. Zero means unlimited. "
+ DEFVAL { 0 }
+ ::= { nwAppnSysCfgLocalNode 16 }
+
+nwAppnSysMaxIsrSessions OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum number of intermediate routing sessions permitted
+ by APPN Routing Services at one time. This must be a non-negative
+ number."
+ DEFVAL { 1000 }
+ ::= { nwAppnSysCfgLocalNode 18 }
+
+nwAppnSysIsrUpperThresh OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The thresholds control the congestion status of APPN routing
+ services. If the number of ISR sessions exceeds the upper
+ threshold, congestion status changes from uncongested to congested.
+ When this occurs, the status will not become uncongested until the
+ the number of ISR sessions fall below the lower threshold. The
+ lower threshold should be less than the upper threshold to prevent
+ thrashing. The upper threshold should be lower than
+ nwAppnSysMaxIsrSessions. This must be a non-negative number."
+ DEFVAL { 900 }
+ ::= { nwAppnSysCfgLocalNode 19 }
+
+nwAppnSysIsrLowerThresh OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifes the number of ISR sessions at which congestion status will
+ revert to uncongested. This must be a non-negative number.
+ nwAppnSysIsrLowerThresh must be less than nwAppnSysIsrUpperThresh
+ to prevent thrashing. "
+ DEFVAL { 800 }
+ ::= { nwAppnSysCfgLocalNode 20 }
+
+nwAppnSysIsrMaxRuSize OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum RU size supported for intermediate sessions.
+ Note: the number provided will be rounded up to the
+ next valid RU size if necessary after APPN Routing Services has
+ been successfully enabled. A subsequent GET operation on
+ nwAppnSysMaxLocates will reflect this new value."
+ DEFVAL { 1024 }
+ ::= { nwAppnSysCfgLocalNode 21 }
+
+nwAppnSysIsrRcvPaceWind OBJECT-TYPE
+ SYNTAX INTEGER (1..63)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies suggested receive pacing window size for intermediate
+ sessions. This value may be used as a fixed window size for
+ fixed pacing, or as a tuning value for adaptive pacing. "
+ DEFVAL { 8 }
+ ::= { nwAppnSysCfgLocalNode 22 }
+
+nwAppnSysRtAddResist OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies a desirability factor for APPN Routing Services to
+ perform intermediate session routing. 255 is least desirable
+ and 0 is more desirable. "
+ DEFVAL { 0 }
+ ::= { nwAppnSysCfgLocalNode 23 }
+
+nwAppnSysStopType OBJECT-TYPE
+ SYNTAX INTEGER {
+ abort(1), -- Shutdown APPN Routing Services immediately
+ immediate(2), -- deactivate links then abort(1)
+ quiesce(3), -- advertize quiesce, deactivate endpoint
+ -- sessions, then immediate(2)
+ quiesceIsr(4) -- allow all isr sessions to end then
+ -- quiesce(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the type of APPN Routing Services shutdown.
+ Once specified, select disable from nwAppnSysAdminStatus. The
+ shutdown choices are as follows:
+
+ abort(1) All APPN Routing Services components are immediately
+ stopped and resources released. To become active again,
+ the APPN Routing Services must be enabled.
+ immediate(2) APPN Routing Services immediately deactivates all links
+ then performs abort(1) processing.
+ quiesce(3) APPN Routing Services indicates to other APPN network
+ nodes that it is quiesced. Session limits
+ are reset on all modes, UNBINDs are issued
+ on all endpoint sessions (CP-CP sessions last),
+ and then immediate(2) processing is performed.
+ quiesceIsr(4) Allows all intermediate sessions to end,
+ then performs the quiesce(3) processing."
+ DEFVAL { quiesceIsr }
+ ::= { nwAppnSysCfgLocalNode 24 }
+
+nwAppnSysBlockNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This represents the 3 hexadecimal digit block number which
+ precedes the 5 digit id number in the 8 digit node id used in
+ XIDs and Alerts. The block number identifies the product type.
+ Both the block number and id number combined, uniquely identify
+ this instance of APPN Routing Services within the installation
+ network."
+-- DEFVAL { 'e08'H }
+ ::= { nwAppnSysCfgLocalNode 25 }
+
+nwAppnSysIdNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(5))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This represents the 5 hexadecimal digit id number which follows
+ the 3 digit block number in the 8 digit node id used in XIDs and
+ Alerts. The id number uniquely identifies this instance of APPN
+ Routing Services within a product type indicated by the block number.
+ Both the block number and id number combined, uniquely identify
+ this instance of APPN Routing Services within the installation
+ network."
+-- DEFVAL { '00000'H }
+ ::= { nwAppnSysCfgLocalNode 26 }
+
+
+-- APPN Router System Group - Local APPN Routing Service Parameters
+-- This group contains tables related to configuring:
+--
+-- LU Definition Table
+
+
+--
+-- LU Table
+--
+
+
+nwAppnSysLuTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnSysLuEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains entries for LUs that are owned by adjacent
+ LEN nodes. Defining or deleting an entry is equivalent to defining
+ or deleting an entry in the directory database. To add an entry,
+ set nwAppnSysLuControl to other. To delete an entry, set
+ nwAppnSysLuControl to delete."
+ ::= { nwAppnSysCfgTables 1 }
+
+nwAppnSysLuEntry OBJECT-TYPE
+ SYNTAX NwAppnSysLuEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry defines an LU entry in the directory database. The
+ fully qualified CP name and the name of the LU are the indexes into
+ this table."
+ INDEX { nwAppnSysCpName, nwAppnSysLuName }
+ ::= { nwAppnSysLuTable 1 }
+
+NwAppnSysLuEntry ::= SEQUENCE {
+ nwAppnSysCpName DisplayString,
+ nwAppnSysLuName DisplayString,
+ nwAppnSysLuControl INTEGER
+ }
+
+nwAppnSysCpName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3..17))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the fully qualified name of the Control Point
+ containing the LU being defined. The format of this name
+ is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and
+ CCCCCCCC is the LU or Control Point name. Valid characters to make
+ up these two strings are uppercase letters A through Z, numerics 0
+ through 9 and the special charcters $, @, and #. The first character
+ of the name must NOT be numeric. Each string must be a maximum length
+ of 8 characters with no embedded spaces and the strings are joined by
+ a dot. This CP name must appear as an Adjacent CP in a link station
+ definition where the adjacent CP type is EN and CP-CP session support
+ is NO."
+ ::= { nwAppnSysLuEntry 1 }
+
+nwAppnSysLuName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the name of the LU being registered. The name format is
+ LLLLLLLL where LLLLLLLL are the characters: uppercase letters
+ A through Z, numerics 0 through 9, and the special characters
+ $, @, and #. The first character of the name must NOT be numeric.
+ The string must be a maximum length of 8 characters with no
+ embedded spaces. Note that the nework identifier of the LU is
+ taken from the fully qualified control point name of the adjacent
+ LEN node (nwAppnSysCpName) which owns the LU. "
+ ::= { nwAppnSysLuEntry 2 }
+
+nwAppnSysLuControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ delete(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this object to delete to remove an entry."
+ ::= { nwAppnSysLuEntry 3 }
+
+
+
+-- APPN System Administration Group
+-- This group contains the objects that pertain to the administration of
+-- APPN Routing Services at a global, system-wide level.
+
+nwAppnSysAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disable(2), -- shut down APPN Routing Services
+ enabled(3) -- start up APPN Routing Services
+
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the system-wide administrative state of APPN Routing Services.
+ If enable(3) is selected, APPN Routing Services is activated.
+
+ There are two cases: the very first activation, and activations
+ subsequent to the successful first activation. Before activating
+ APPN Routing Services the very first time, nwAppnSysRouterId in
+ the System Configuration branch and all objects under
+ nwAppnSysCfgLocalNode must be assigned a value. If not explicitly
+ assigned, default values will be used for objects under
+ nwAppnSysCfgLocalNode. After this first activation has completed
+ successfully, all objects under nwAppnSysCfgLocalNode will be
+ saved in non-volatile RAM and restored for the next node activation
+ at power up time. After this subsequent power up, enable(3) may be
+ selected without setting nwAppnSysRouterId or any objects under
+ under nwAppnSysCfgLocalNode. Those values defined prior to the
+ last power up or reset will be used.
+
+ If disable(2) is selected, APPN Routing Services will become
+ inactive in the manner specifed by nwAppnSysStopType. To
+ modify objects under nwAppnSysCfgLocalNode, nwAppnSysAdminStatus
+ must be disabled. "
+
+ ::= { nwAppnSysAdministration 1 }
+
+nwAppnSysOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disabled(2), -- inactive
+ enabled(3), -- active
+ pendingDisable(4), -- deactivate in progress
+ pendingEnable(5) -- activate in progress
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current operating system-wide status of APPN
+ Routing Services. "
+ ::= { nwAppnSysAdministration 2 }
+
+nwAppnSysAdminReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ reset(2) -- force a reset
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets APPN Routing Services system-wide. Reset (2) forces a
+ restart of APPN Routing Services without a graceful shutdown on
+ any active router ports, without affecting any other routing
+ services."
+ ::= { nwAppnSysAdministration 3 }
+
+nwAppnSysOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the elapsed time, in hundredths of a second, that
+ nwAppnOperStatus has been in its current state."
+ ::= { nwAppnSysAdministration 4 }
+
+nwAppnSysVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current revision level of APPN routing
+ services in textual format."
+ ::= { nwAppnSysAdministration 5 }
+
+
+-- APPN Forwarding Group
+-- This group contains the managed objects used to setup and configure
+-- APPN Routing Services for aggregate, system-wide, port Message Unit
+-- (MU) and byte counters.
+
+
+nwAppnFwdCtrAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the aggregate, system-wide,
+ port Message Unit (MU) and byte counters. Enabled (3) causes
+ these counters to become active. Disabled (2) causes these
+ counters to become inactive."
+ ::= { nwAppnFwdCounters 1 }
+
+nwAppnFwdCtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the aggregate, system-wide port Message Unit (MU)
+ and byte counters. Reset (2) resets the aggregate counters to 0.
+ nwAppnFwdCtrOperationalTime is also reset to 0."
+ ::= { nwAppnFwdCounters 2 }
+
+nwAppnFwdCtrOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the elapsed time, in hundredths of a second,
+ that nwAppnFwdCtrAdminStatus has been in the current state."
+ ::= { nwAppnFwdCounters 3 }
+
+nwAppnFwdCtrInMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have
+ been received system-wide (for all ports) during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 4 }
+
+nwAppnFwdCtrOutMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have
+ been transmitted system-wide (for all ports) during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 5 }
+
+nwAppnFwdCtrFwdMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have
+ been forwarded system-wide (for all ports) during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 6 }
+
+nwAppnFwdCtrFilteredMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 7 }
+
+nwAppnFwdCtrDiscardMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 8 }
+
+nwAppnFwdCtrAddrErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs)
+ that have been received system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime, that contain an address error(s)
+ in the SNA header."
+ ::= { nwAppnFwdCounters 9 }
+
+nwAppnFwdCtrLenErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been received system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime, that contain a length error."
+ ::= { nwAppnFwdCounters 10 }
+
+nwAppnFwdCtrHdrErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been received system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime, that contain an SNA header error
+ other than an address or length error."
+ ::= { nwAppnFwdCounters 11 }
+
+nwAppnFwdCtrInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates number of bytes in Message Units (MUs) that have
+ been received system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 12 }
+
+nwAppnFwdCtrOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs) that
+ have been forwarded system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 13 }
+
+nwAppnFwdCtrFwdBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs) that
+ have been forwarded system-wide (for all ports), during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 14 }
+
+nwAppnFwdCtrFilteredBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 15 }
+
+nwAppnFwdCtrDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 16 }
+
+nwAppnFwdCtrHostInMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been delivered system-wide (for all ports), to local half
+ sessions during nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 17 }
+
+nwAppnFwdCtrHostOutMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been successfully sent from local half sessions system-wide
+ (for all ports), to Path Control during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 18 }
+
+nwAppnFwdCtrHostDiscardMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 19 }
+
+
+nwAppnFwdCtrHostInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs)
+ that have been delivered system-wide (for all ports), to
+ local half sessions during nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 20 }
+
+nwAppnFwdCtrHostOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs)
+ that have been successfully sent from local half sessions
+ system-wide (for all ports), to Path Control during
+ nwAppnFwdCtrOperationalTime."
+ ::= { nwAppnFwdCounters 21 }
+
+nwAppnFwdCtrHostDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdCounters 22 }
+
+
+-- APPN Forwarding Port Table
+-- This table contains the managed objects used to setup and configure
+-- each port used by APPN Routing Services.
+--
+--
+nwAppnFwdIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnFwdIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains an entry for each router port which can
+ be used by APPN Routing Services. This table is indexed by
+ nwAppnFwdIfIndex, which indicates the value of MIB 2 ifindex
+ which identifes the router port for which an entry exists.
+ These port configuration entries will be provided automatically
+ based on physical port configuration. Such entries cannot be
+ deleted - only modified."
+ ::= { nwAppnFwdIfConfig 1 }
+
+nwAppnFwdIfEntry OBJECT-TYPE
+ SYNTAX NwAppnFwdIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the APPN Routing Services port
+ configuration for the router port for which the entry exists."
+ INDEX { nwAppnFwdIfIndex }
+ ::= { nwAppnFwdIfTable 1 }
+
+NwAppnFwdIfEntry ::=
+ SEQUENCE {
+ nwAppnFwdIfIndex INTEGER,
+ nwAppnFwdIfAdminStatus INTEGER,
+ nwAppnFwdIfOperStatus INTEGER,
+ nwAppnFwdIfOperationalTime TimeTicks,
+ nwAppnFwdIfControl INTEGER,
+ nwAppnFwdIfMtu INTEGER,
+ nwAppnFwdIfForwarding INTEGER,
+ nwAppnFwdIfFrameType INTEGER,
+ nwAppnFwdIfAclIdentifier INTEGER,
+ nwAppnFwdIfAclStatus INTEGER,
+ nwAppnFwdIfCacheControl INTEGER,
+ nwAppnFwdIfCacheEntries Counter,
+ nwAppnFwdIfCacheHits Counter,
+ nwAppnFwdIfCacheMisses Counter
+ }
+
+nwAppnFwdIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the value of MIB2 ifindex, which identifies the
+ router port for which the entry exists. "
+ ::= { nwAppnFwdIfEntry 1 }
+
+nwAppnFwdIfAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disable(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of an APPN Routing Services
+ port for which the entry exists. enabled(3) causes the
+ APPN Routing Services port to become active. disable(2)
+ causes it to become inactive. There are various choices
+ for the method by which the port can be disabled, which are
+ enumerated by nwAppnExtIfStopType. "
+ ::= { nwAppnFwdIfEntry 2 }
+
+nwAppnFwdIfOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disabled(2), -- inactive
+ enabled(3), -- active
+ pendingDisable(4), -- deactivate in progress
+ pendingEnable(5) -- activate in progress
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current operating condition of the APPN Routing
+ Services port for which the entry exists."
+ ::= { nwAppnFwdIfEntry 3 }
+
+nwAppnFwdIfOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the elapsed time, in hundredths of a second, that
+ nwAppnFwdIfOperStatus has been in the current state."
+ ::= { nwAppnFwdIfEntry 4 }
+
+nwAppnFwdIfControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 5 }
+
+nwAppnFwdIfMtu OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 6 }
+
+nwAppnFwdIfForwarding OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 7 }
+
+nwAppnFwdIfFrameType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ethernet(2),
+ i8022(4),
+ sync(8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the framing type for the APPN Routing Services port
+ for which the entry exists. "
+ ::= { nwAppnFwdIfEntry 8 }
+
+nwAppnFwdIfAclIdentifier OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 9 }
+
+nwAppnFwdIfAclStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 10 }
+
+nwAppnFwdIfCacheControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disable(2),
+ enable(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 11 }
+
+nwAppnFwdIfCacheEntries OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 12 }
+
+nwAppnFwdIfCacheHits OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 13 }
+
+nwAppnFwdIfCacheMisses OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs. Setting this object has no effect."
+ ::= { nwAppnFwdIfEntry 14 }
+
+
+-- The APPN Routing Services Port Extension Table
+-- This table contains additional objects used to setup and configure
+-- APPN Routing Services on a per port basis.
+
+nwAppnExtensionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnExtEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains additional APPN definitions for each
+ physical port. Entries cannot be added to or deleted from this
+ table. With the exception of nwAppnExtIfStopType, objects in
+ this table may only be modified when nwAppnFwdIfAdminStatus
+ is disabled. Note: if APPN Routing Services is not active, no
+ entries will exist for this table. "
+ ::= { nwAppnFwdIfConfig 2 }
+
+nwAppnExtEntry OBJECT-TYPE
+ SYNTAX NwAppnExtEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies additional APPN configuration parameters
+ for the port for which this entry exists."
+ INDEX { nwAppnExtIfIndex }
+ ::= { nwAppnExtensionTable 1 }
+
+NwAppnExtEntry ::=
+ SEQUENCE {
+ nwAppnExtIfIndex INTEGER,
+ nwAppnExtIfPortName DisplayString,
+ nwAppnExtIfPortType INTEGER,
+ nwAppnExtIfDlcType INTEGER,
+ nwAppnExtIfMaxRBtuSize INTEGER,
+ nwAppnExtIfTotLsActLim INTEGER,
+ nwAppnExtIfInbLsActLim INTEGER,
+ nwAppnExtIfOutbLsActLim INTEGER,
+ nwAppnExtIfLocalLsRole INTEGER,
+ nwAppnExtIfActXidXchgLimit INTEGER,
+ nwAppnExtIfNonActXidXchgLimit INTEGER,
+ nwAppnExtIfLsXmitRcvCap INTEGER,
+ nwAppnExtIfMaxIfrmRcvd INTEGER,
+ nwAppnExtIfDfltTargetPacing INTEGER,
+ nwAppnExtIfDfltMaxSBtuSize INTEGER,
+ nwAppnExtIfDfltEffectCap INTEGER,
+ nwAppnExtIfDfltConnectCost INTEGER,
+ nwAppnExtIfDfltByteCost INTEGER,
+ nwAppnExtIfDfltSecurity INTEGER,
+ nwAppnExtIfDfltPropDelay INTEGER,
+ nwAppnExtIfDfltUsrDef1 INTEGER,
+ nwAppnExtIfDfltUsrDef2 INTEGER,
+ nwAppnExtIfDfltUsrDef3 INTEGER,
+ nwAppnExtIfStopType INTEGER,
+ nwAppnExtIfCpCpSupp INTEGER,
+ nwAppnExtIfLimitedRsrc INTEGER,
+ nwAppnExtIfAddress OCTET STRING,
+ nwAppnExtIfSsap OCTET STRING
+ }
+
+nwAppnExtIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the primary index into the APPN port extension table.
+ This number corresponds to the index into the nwAppnFwdIfTable. "
+ ::= { nwAppnExtEntry 1 }
+
+nwAppnExtIfPortName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the user friendly name for this port. "
+ ::= { nwAppnExtEntry 2 }
+
+nwAppnExtIfPortType OBJECT-TYPE
+ SYNTAX INTEGER {
+ nonswitched(1),
+ switched(2),
+ satf(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the type of line used by the port. The value
+ corresponds to one of the following: nonswitched(1),
+ switched(2), or satf(3). "
+ ::= { nwAppnExtEntry 4 }
+
+nwAppnExtIfDlcType OBJECT-TYPE
+ SYNTAX INTEGER {
+ llc2(1),
+ sdlc(2),
+ x25(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the type of DLC using the port. "
+ ::= { nwAppnExtEntry 5 }
+
+nwAppnExtIfMaxRBtuSize OBJECT-TYPE
+ SYNTAX INTEGER (99..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the maximum Message Unit (MU) size that can be received. "
+ DEFVAL { 2048 }
+ ::= { nwAppnExtEntry 6 }
+
+nwAppnExtIfTotLsActLim OBJECT-TYPE
+ SYNTAX INTEGER (1..256)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of links that can be active on this
+ port. If nwAppnExtIfPortType = nonswitched(1) and
+ nwAppnExtIfLocalLsRole = negotiable(1), or secondary(3), then
+ this value must be set to 1. "
+ DEFVAL { 16 }
+ ::= { nwAppnExtEntry 7 }
+
+nwAppnExtIfInbLsActLim OBJECT-TYPE
+ SYNTAX INTEGER (0..256)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of inbound links that can be active on
+ this port. If nwAppnExtIfPortType = nonswitched(1) and
+ nwAppnExtIfLocalLsRole = negotiable(1) or primary(2), then this
+ value must be set to 0. "
+ DEFVAL { 8 }
+ ::= { nwAppnExtEntry 8 }
+
+nwAppnExtIfOutbLsActLim OBJECT-TYPE
+ SYNTAX INTEGER (0..256)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of outbound links that can be active on
+ this port. If nwAppnExtIfPortType = nonswitched(1) and
+ nwAppnExtIfLocalLsRole = negotiable(1), then this value must be
+ set to 0. If nwAppnExtIfLocalLsRole = primary(2), then this value
+ must be set the same as nwAppnExtIfTotLsActLim. "
+ DEFVAL { 8 }
+ ::= { nwAppnExtEntry 9 }
+
+nwAppnExtIfLocalLsRole OBJECT-TYPE
+ SYNTAX INTEGER { negotiable(1),
+ primary(2),
+ secondary(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the link station role - primary, secondary, or
+ negotiable. For nwAppnExtIfPortType = satf(3), the link station
+ role must be negotiable(1). "
+ DEFVAL { negotiable }
+ ::= { nwAppnExtEntry 10 }
+
+nwAppnExtIfActXidXchgLimit OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of activation XIDs that may be
+ exchanged. "
+ DEFVAL { 9 }
+ ::= { nwAppnExtEntry 11 }
+
+nwAppnExtIfNonActXidXchgLimit OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of non-activation XIDs that may be
+ exchanged. "
+ DEFVAL { 5 }
+ ::= { nwAppnExtEntry 12 }
+
+nwAppnExtIfLsXmitRcvCap OBJECT-TYPE
+ SYNTAX INTEGER { twowaysimultaneous(1),
+ twowayalternating(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the link station's transmit/receive capability. "
+ DEFVAL { twowaysimultaneous }
+ ::= { nwAppnExtEntry 13 }
+
+nwAppnExtIfMaxIfrmRcvd OBJECT-TYPE
+ SYNTAX INTEGER (1..127)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the maximum number of I-frames received before an
+ acknowledgment is sent to the sender. "
+ DEFVAL { 4 }
+ ::= { nwAppnExtEntry 14 }
+
+nwAppnExtIfDfltTargetPacing OBJECT-TYPE
+ SYNTAX INTEGER (1..32767)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the pacing window size for BINDs on this transmission
+ group. "
+ DEFVAL { 7 }
+ ::= { nwAppnExtEntry 15 }
+
+nwAppnExtIfDfltMaxSBtuSize OBJECT-TYPE
+ SYNTAX INTEGER (99..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the maximum Message Unit (MU) size which can be sent. "
+ DEFVAL { 2048 }
+ ::= { nwAppnExtEntry 16 }
+
+nwAppnExtIfDfltEffectCap OBJECT-TYPE
+ SYNTAX INTEGER (0..603979776)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the default maximum kilo bits per second rate
+ (line speed) for all links on this port. "
+ ::= { nwAppnExtEntry 17 }
+
+nwAppnExtIfDfltConnectCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the default cost per connect time for all link
+ stations on this port. 0 is the lowest cost and 255 is the
+ largest cost. "
+ ::= { nwAppnExtEntry 18 }
+
+nwAppnExtIfDfltByteCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the default Cost per Byte for link stations. 0 is
+ the lowest cost and 255 is the largest cost. "
+ ::= { nwAppnExtEntry 19 }
+
+nwAppnExtIfDfltSecurity OBJECT-TYPE
+ SYNTAX INTEGER { nonsecure(1), --X'01'
+ publicSwitchNw(32), --X'20'
+ undergroundCable(64), --X'40'
+ secureConduit(96), --X'60'
+ guardedConduit(128), --X'80'
+ encrypted(160), --X'A0'
+ guardedRadiation(192) --X'C0'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specify one of the following security selections:
+
+ non-secure - specifies no security.
+ public switched - data flows over a public switched
+ network.
+ underground cable - data transmitted over a secure
+ underground cable.
+ secure conduit - line is secure conduit that is not
+ guarded.
+ guarded conduit - conduit that is protected against
+ physical tapping.
+ encrypted - encryption over the line.
+ guarded radiation - line is proected against physical
+ and radiation tapping. "
+
+ ::= { nwAppnExtEntry 20 }
+
+nwAppnExtIfDfltPropDelay OBJECT-TYPE
+ SYNTAX INTEGER {
+ minimum(0), --X'00'
+ negligible(384), --X'4C'
+ terrestrial(9216), --X'71'
+ packetswitched(147456), --X'91'
+ long(294912), --X'99'
+ maximum(2013265920) --X'FF'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the propagation delay which represents the relative
+ time it takes for a signal to travel the length of the link in
+ microseconds, with some of the more common default values
+ enumerated. The default times in parentheses are in microseconds.
+ These default values fall into the following ranges:
+
+ minimum - no propagation delay
+ negligible, lan - less than 480 microseconds
+ terrestrial, telephone - between 480 and 49,512
+ microseconds
+ packetswitched - between 49,512 and 245,760
+ microseconds
+ long, satellite - more than 245760 microseconds.
+ maximum - the maximum propagation delay. "
+ ::= { nwAppnExtEntry 21 }
+
+nwAppnExtIfDfltUsrDef1 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 1. "
+ DEFVAL { 128 }
+ ::= { nwAppnExtEntry 22 }
+
+nwAppnExtIfDfltUsrDef2 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 2. "
+ DEFVAL { 128 }
+ ::= { nwAppnExtEntry 23 }
+
+nwAppnExtIfDfltUsrDef3 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 3. "
+ DEFVAL { 128 }
+ ::= { nwAppnExtEntry 24 }
+
+nwAppnExtIfStopType OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediate(1),
+ orderly(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the type of shutdown for APPN Routing Services
+ on the port. Once set, nwAppnFwdIfAdminStatus may
+ be set to disable. The disable choices are as follows:
+
+ immediate(1) causes the link stations belonging to the
+ physical port to be disabled immediately
+ without flushing pending messages and
+ without initiating an orderly disconnect sequence.
+ orderly(2) causes pending messages in link stations to be
+ flushed, followed by an orderly disconnect
+ sequence. The link station is then disabled. "
+ DEFVAL { orderly }
+ ::= { nwAppnExtEntry 25 }
+
+nwAppnExtIfCpCpSupp OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether CP-CP sessions are permitted on dynamic
+ links generated on this port. "
+ DEFVAL { yes }
+ ::= { nwAppnExtEntry 26 }
+
+nwAppnExtIfLimitedRsrc OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether dynamic links generated on this port
+ are a limited resource. A limited resource link will
+ be deactivated when there are no sessions using the link."
+ DEFVAL { no }
+ ::= { nwAppnExtEntry 27 }
+
+nwAppnExtIfAddress OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the physical address of this port depending on the
+ media type. For token ring or ethernet ports, the information is
+ the 6 byte MAC address which starts in byte 1 and ends in byte 6.
+ For token ring ports the MAC address must be specified in non-
+ canonical format. For ethernet ports the MAC address must be
+ specified in canonical format. For frame relay ports, there is
+ no associated address, i.e., it will be a zero length octet string."
+ ::= { nwAppnExtEntry 28 }
+
+nwAppnExtIfSsap OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For token ring or ethernet ports specifies the Source SAP Address
+ of this port. "
+ DEFVAL { '04'h }
+ ::= { nwAppnExtEntry 29 }
+
+
+--
+-- Connection Network Tables
+--
+
+nwAppnIfCnPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnIfCnPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains definitions for the Connection
+ Network port table which defines which local ports can
+ access a connection network. To add a row to the table,
+ nwAppnIfCnPtFqName and nwAppnIfCnPtName are required entries.
+ To delete a row, set the control field to delete.
+ Adding the first row for a connection network implicitly
+ creates the connection network and deleting the last
+ remaining row for a connection network implicitly removes
+ the connection network."
+ ::= { nwAppnIfCn 1 }
+
+nwAppnIfCnPortEntry OBJECT-TYPE
+ SYNTAX NwAppnIfCnPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the APPN Connection Network port definitions."
+ INDEX { nwAppnIfCnPtFqName, nwAppnIfCnPtName }
+ ::= { nwAppnIfCnPortTable 1 }
+
+NwAppnIfCnPortEntry ::=
+ SEQUENCE {
+ nwAppnIfCnPtFqName DisplayString,
+ nwAppnIfCnPtName DisplayString,
+ nwAppnIfCnPtControl INTEGER
+ }
+
+nwAppnIfCnPtFqName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3..17))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the fully-qualified Name of the Virtual Routing Node.
+ The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the
+ network identifier and CCCCCCCC is the Control Point name. Valid
+ characters to make up these two strings are uppercase letters
+ A through Z, numerics 0 through 9, and the special characters
+ $, @, and #. The first character of the name must NOT be
+ numeric. Each string must be a maximum length of 8 characters
+ with no embedded spaces and the strings are joined by a dot. "
+ ::= { nwAppnIfCnPortEntry 1 }
+
+nwAppnIfCnPtName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies one of the ports which can access this Connection
+ Network."
+ ::= { nwAppnIfCnPortEntry 2 }
+
+nwAppnIfCnPtControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ delete(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this object to delete to delete this port from this
+ Connection Network."
+ ::= { nwAppnIfCnPortEntry 3 }
+
+
+nwAppnIfCnTgCharTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnIfCnTgCharEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the APPN definitions for a Connection
+ Network's transmission group characteristics. Rows may be
+ neither added nor deleted, only modified. Rows are
+ added/deleted implicitly through CnPortTable."
+ ::= { nwAppnIfCn 2 }
+
+
+nwAppnIfCnTgCharEntry OBJECT-TYPE
+ SYNTAX NwAppnIfCnTgCharEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the APPN transmission group characteristics for
+ the Connection Network."
+ INDEX { nwAppnIfCnTgFqName }
+ ::= { nwAppnIfCnTgCharTable 1 }
+
+NwAppnIfCnTgCharEntry ::=
+ SEQUENCE {
+ nwAppnIfCnTgFqName DisplayString,
+ nwAppnIfCnTgEffectCap INTEGER,
+ nwAppnIfCnTgConnectCost INTEGER,
+ nwAppnIfCnTgByteCost INTEGER,
+ nwAppnIfCnTgSecurity INTEGER,
+ nwAppnIfCnTgPropDelay INTEGER,
+ nwAppnIfCnTgUsrDef1 INTEGER,
+ nwAppnIfCnTgUsrDef2 INTEGER,
+ nwAppnIfCnTgUsrDef3 INTEGER
+ }
+
+nwAppnIfCnTgFqName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3..17))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the fully-qualified Name of the Virtual Routing Node.
+ The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the
+ network identifier and CCCCCCCC is the Control Point name. Valid
+ characters to make up these two strings are uppercase letters
+ A through Z, numerics 0 through 9, and the special characters
+ #, $, and @. The first character of the name must NOT be
+ numeric. Each string must be a maximum length of 8 characters
+ with no embedded spaces and the strings are joined by a dot. "
+ ::= { nwAppnIfCnTgCharEntry 1 }
+
+nwAppnIfCnTgEffectCap OBJECT-TYPE
+ SYNTAX INTEGER (0..603979776)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the maximum kilo bits per second rate (link speed) for
+ the connection network. "
+ ::= { nwAppnIfCnTgCharEntry 2 }
+
+nwAppnIfCnTgConnectCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the cost per connect time for the Connection Network.
+ 0 is the lowest cost and 255 is the largest cost."
+ ::= { nwAppnIfCnTgCharEntry 3 }
+
+nwAppnIfCnTgByteCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the cost per byte for the Connection Network.
+ 0 is the lowest cost and 255 is the largest cost."
+ ::= { nwAppnIfCnTgCharEntry 4 }
+
+nwAppnIfCnTgSecurity OBJECT-TYPE
+ SYNTAX INTEGER { nonsecure(1), --X'01'
+ publicSwitchNw(32), --X'20'
+ undergroundCable(64), --X'40'
+ secureConduit(96), --X'60'
+ guardedConduit(128), --X'80'
+ encrypted(160), --X'A0'
+ guardedRadiation(192) --X'C0'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Connection Network, specify one of the following
+ security selections:
+ non-secure - specifies no security.
+ public switched - data flows over a public switched
+ network.
+ underground cable - data transmitted over a secure
+ underground cable.
+ secure conduit - line is secure conduit that is not
+ guarded.
+ guarded conduit - conduit that is protected against
+ physical tapping.
+ encrypted - encryption over the line.
+ guarded radiation - line is proected against physical
+ and radiation tapping. "
+ ::= { nwAppnIfCnTgCharEntry 5 }
+
+nwAppnIfCnTgPropDelay OBJECT-TYPE
+ SYNTAX INTEGER {
+ minimum(0), --X'00'
+ negligible(384), --X'4C'
+ terrestrial(9216), --X'71'
+ packetswitched(147456), --X'91'
+ long(294912), --X'99'
+ maximum(2013265920) --X'FF'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the propagation delay which represents the time it
+ takes for a signal to travel the length of the link in
+ microseconds, with some of the more common default values
+ enumerated. The default times in parentheses are in microseconds.
+ These default values fall into the following ranges:
+
+ minimum - no propagation delay
+ negligible, lan - less than 480 microseconds
+ terrestrial, telephone - between 480 and 49,512
+ microseconds
+ packetswitched - between 49,512 and 245,760
+ microseconds
+ long, satellite - more than 245760 microseconds.
+ maximum - the maximum propagation delay. "
+ ::= { nwAppnIfCnTgCharEntry 6 }
+
+nwAppnIfCnTgUsrDef1 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 1. "
+ DEFVAL { 128 }
+ ::= { nwAppnIfCnTgCharEntry 7 }
+
+nwAppnIfCnTgUsrDef2 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 2. "
+ DEFVAL { 128 }
+ ::= { nwAppnIfCnTgCharEntry 8 }
+
+nwAppnIfCnTgUsrDef3 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 3. "
+ DEFVAL { 128 }
+ ::= { nwAppnIfCnTgCharEntry 9 }
+
+
+-- APPN Forwarding Ports Counter Table
+-- This table contains the objects that specify the Message Unit (MU) and byte
+-- counters for each port used by APPN Routing Services.
+--
+--
+nwAppnFwdIfCtrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnFwdIfCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the Message Unit (MU) and byte counters for
+ each port configured and enabled for APPN Routing Services. "
+ ::= { nwAppnFwdIfCounters 1 }
+
+nwAppnFwdIfCtrEntry OBJECT-TYPE
+ SYNTAX NwAppnFwdIfCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry indicates Message Units (MU) and byte counts on
+ the router port for which this entry exists."
+ INDEX { nwAppnFwdIfCtrIfIndex }
+ ::= { nwAppnFwdIfCtrTable 1 }
+
+NwAppnFwdIfCtrEntry ::=
+ SEQUENCE {
+ nwAppnFwdIfCtrIfIndex INTEGER,
+ nwAppnFwdIfCtrAdminStatus INTEGER,
+ nwAppnFwdIfCtrReset INTEGER,
+ nwAppnFwdIfCtrOperationalTime TimeTicks,
+ nwAppnFwdIfCtrInMus Counter,
+ nwAppnFwdIfCtrOutMus Counter,
+ nwAppnFwdIfCtrFwdMus Counter,
+ nwAppnFwdIfCtrFilteredMus Counter,
+ nwAppnFwdIfCtrDiscardMus Counter,
+ nwAppnFwdIfCtrAddrErrMus Counter,
+ nwAppnFwdIfCtrLenErrMus Counter,
+ nwAppnFwdIfCtrHdrErrMus Counter,
+ nwAppnFwdIfCtrInBytes Counter,
+ nwAppnFwdIfCtrOutBytes Counter,
+ nwAppnFwdIfCtrFwdBytes Counter,
+ nwAppnFwdIfCtrFilteredBytes Counter,
+ nwAppnFwdIfCtrDiscardBytes Counter,
+ nwAppnFwdIfCtrHostInMus Counter,
+ nwAppnFwdIfCtrHostOutMus Counter,
+ nwAppnFwdIfCtrHostDiscardMus Counter,
+ nwAppnFwdIfCtrHostInBytes Counter,
+ nwAppnFwdIfCtrHostOutBytes Counter,
+ nwAppnFwdIfCtrHostDiscardBytes Counter
+ }
+
+nwAppnFwdIfCtrIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the value of MIB 2 ifindex, which identifies the
+ router port for which the entry exists. This is the primary
+ index into the APPN per-port counter table. "
+ ::= { nwAppnFwdIfCtrEntry 1 }
+
+nwAppnFwdIfCtrAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the per-port Message Unit
+ (MU) and byte counters on the router port for which the entry
+ exists. enabled(3) causes these counters to become active.
+ disabled(2) causes these counters to become inactive."
+ ::= { nwAppnFwdIfCtrEntry 2 }
+
+nwAppnFwdIfCtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the per-port Message Unit (MU) and byte counters on the
+ router port for which this entry exists. reset (2) resets the
+ counters to 0. nwAppnFwdIfCtrOperationalTime is also reset to 0."
+ ::= { nwAppnFwdIfCtrEntry 3 }
+
+nwAppnFwdIfCtrOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the amount of time in hundreths of a second that the
+ per-port Message Unit (MU) and byte counters have been active on
+ the APPN routing services port for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 4 }
+
+nwAppnFwdIfCtrInMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have been
+ received, during nwAppnFwdIfCtrOperationaltime on the router port
+ for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 5 }
+
+nwAppnFwdIfCtrOutMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have been
+ transmitted, during nwAppnFwdIfCtrOperationalTime, on the router
+ port for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 6 }
+
+nwAppnFwdIfCtrFwdMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MU)s that have
+ been forwarded during nwAppnFwdIfCtrOperationalTime on the router
+ port for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 7 }
+
+nwAppnFwdIfCtrFilteredMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 8 }
+
+nwAppnFwdIfCtrDiscardMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 9 }
+
+nwAppnFwdIfCtrAddrErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that contain
+ an address error in the SNA header that have been received
+ during nwAppnFwdIfCtrOperationalTime on the router port for which
+ this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 10 }
+
+nwAppnFwdIfCtrLenErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that contain
+ a length error that have been received during
+ nwAppnFwdIfCtrOperationalTime on the router port for which
+ this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 11 }
+
+nwAppnFwdIfCtrHdrErrMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that contain
+ a header error other than an address or length error that have
+ been received during nwAppnFwdIfCtrOperationalTime on the router
+ port for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 12 }
+
+nwAppnFwdIfCtrInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in the Message Units (MU)s
+ that have been received, during nwAppnFwdIfCtrOperationalTime,
+ on the router port for which the entry exists."
+ ::= { nwAppnFwdIfCtrEntry 13 }
+
+nwAppnFwdIfCtrOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in the Message Units (MU)s
+ that have been transmitted, during nwAppnFwdIfCtrOperationalTime,
+ on the router port for which the entry exists."
+ ::= { nwAppnFwdIfCtrEntry 14 }
+
+nwAppnFwdIfCtrFwdBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MU)s that
+ have been forwarded during nwAppnFwdIfCtrOperationalTime on the
+ router port for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 15 }
+
+nwAppnFwdIfCtrFilteredBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 16 }
+
+nwAppnFwdIfCtrDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 17 }
+
+nwAppnFwdIfCtrHostInMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been delivered to local half sessions during
+ nwAppnFwdIfCtrOperationalTime on the router port for which this
+ entry exists."
+ ::= { nwAppnFwdIfCtrEntry 18 }
+
+nwAppnFwdIfCtrHostOutMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of Message Units (MUs) that have
+ been successfully sent from local half sessions to Path Control
+ during nwAppnFwdIfCtrOperationalTime on the router port for
+ which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 19 }
+
+nwAppnFwdIfCtrHostDiscardMus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 20 }
+
+nwAppnFwdIfCtrHostInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs)
+ that have been delivered to local half sessions during
+ nwAppnFwdIfCtrOperationalTime on the router port for which this
+ entry exists."
+ ::= { nwAppnFwdIfCtrEntry 21 }
+
+nwAppnFwdIfCtrHostOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total number of bytes in Message Units (MUs) that
+ have been successfully sent from local half sessions to Path
+ Control during nwAppnFwdIfCtrOperationalTime on the router port
+ for which this entry exists."
+ ::= { nwAppnFwdIfCtrEntry 22 }
+
+nwAppnFwdIfCtrHostDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdIfCtrEntry 23 }
+
+
+
+-- APPN Forwarding Adjacent Link Station Table
+-- This table contains the managed objects used to set up and configure
+-- links to adjacent link stations. Only those links that are configured by the
+-- user can be modified. Links which are active cannot be modified.
+-- If an attempt is made to modify an active link, the operational status
+-- will indicate busy-failed.
+
+nwAppnFwdLsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnFwdLsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the configuration and management
+ information for links to adjacent link stations. This table is
+ indexed by nwAppnFwdLsName. Operations which apply are add,
+ delete, modify, enable, and disable. To add a row to the
+ table, the required fields in the row must be provided.
+ The required fields are nwAppnFwdLsPortName and
+ nwAppnFwdLsDestAddr. All other fields which are not provided
+ will be defaulted. To enable a link select enable(3) from
+ nwAppnFwdLsAdminStatus. To delete a row, set nwAppnFwdLsControl
+ to delete(3). To disable a link set nwAppnFwdLsStopType and
+ then select disable(2) in nwAppnFwdLsAdminStatus.
+ If nwAppnFwdLsStopType is not selected, the link is disabled in
+ an orderly fashion. "
+ ::= { nwAppnFwdLsConfig 1 }
+
+nwAppnFwdLsEntry OBJECT-TYPE
+ SYNTAX NwAppnFwdLsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the configuration for a link to an adjacent link
+ station for which the entry exists."
+ INDEX { nwAppnFwdLsName }
+ ::= { nwAppnFwdLsTable 1 }
+
+NwAppnFwdLsEntry ::=
+ SEQUENCE {
+ nwAppnFwdLsName DisplayString,
+ nwAppnFwdLsAdminStatus INTEGER,
+ nwAppnFwdLsOperStatus INTEGER,
+ nwAppnFwdLsOperationalTime TimeTicks,
+ nwAppnFwdLsControl INTEGER,
+ nwAppnFwdLsPortName DisplayString,
+ nwAppnFwdLsAdjCpName DisplayString,
+ nwAppnFwdLsAdjCpType INTEGER,
+ nwAppnFwdLsAutoActSupport INTEGER,
+ nwAppnFwdLsLimitedRsrc INTEGER,
+ nwAppnFwdLsSscpSession INTEGER,
+ nwAppnFwdLsPuName DisplayString,
+ nwAppnFwdLsBackLvlLenEN INTEGER,
+ nwAppnFwdLsCpCpSessSupp INTEGER,
+ nwAppnFwdLsEffectCap INTEGER,
+ nwAppnFwdLsConnectCost INTEGER,
+ nwAppnFwdLsByteCost INTEGER,
+ nwAppnFwdLsSecurity INTEGER,
+ nwAppnFwdLsPropDelay INTEGER,
+ nwAppnFwdLsUsrDef1 INTEGER,
+ nwAppnFwdLsUsrDef2 INTEGER,
+ nwAppnFwdLsUsrDef3 INTEGER,
+ nwAppnFwdLsTrgtPacingCount INTEGER,
+ nwAppnFwdLsMaxSendBtu INTEGER,
+ nwAppnFwdLsNumActiveSession INTEGER,
+ nwAppnFwdLsdynamicLs INTEGER,
+ nwAppnFwdLsStopType INTEGER,
+ nwAppnFwdLsPortNbr INTEGER,
+ nwAppnFwdLsDestAddr OCTET STRING,
+ nwAppnFwdLsDsap OCTET STRING,
+ nwAppnFwdLsBlockNum DisplayString,
+ nwAppnFwdLsIdNum DisplayString
+ }
+
+nwAppnFwdLsName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the primary index to the adjacent link station table
+ (nwAppnFwdLsTable). "
+ ::= { nwAppnFwdLsEntry 1 }
+
+nwAppnFwdLsAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disable(2),
+ enable(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of a link to an adjacent
+ link station. enabled(3) causes the link to become established.
+ disable(2) causes the link to terminate. There are various
+ severities of disabling a link which are selected via the leaf
+ node nwAppnFwdLsStopType described further within this branch. "
+ ::= { nwAppnFwdLsEntry 2 }
+
+nwAppnFwdLsOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disabled(2), -- inactive
+ enabled(3), -- active
+ pendingDisable(4), -- deactivate in progress
+ pendingEnable(5) -- activate in progress
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the current operating status of the link for which this
+ entry exists."
+ ::= { nwAppnFwdLsEntry 3 }
+
+nwAppnFwdLsOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the elapsed time, in hundredths of a second, that
+ nwAppnFwdLsAdminStatus has been either enabled or DISABLED.
+ If the operational state is pending-disable,
+ nwAppnFwdLsOperationalTime indicates the amount of time since
+ the state was enabled. If the operational state is pending-enable,
+ nwAppnFwdLsOperationalTime indicates the amount of time since the
+ state was DISABLED."
+ ::= { nwAppnFwdLsEntry 4 }
+
+nwAppnFwdLsControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ delete(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this object to delete in order to delete the entry."
+ ::= { nwAppnFwdLsEntry 5 }
+
+nwAppnFwdLsPortName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This link station port name corresponds to the port name
+ index into the the nwAppnExtensionTable which describes the
+ router port on which the adjacent link station is defined."
+ ::= { nwAppnFwdLsEntry 6 }
+
+nwAppnFwdLsAdjCpName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (3..17))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the fully-qualified, 17 byte long, adjacent Control
+ Point name. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN
+ is the network identifier and CCCCCCCC is the Control Point name.
+ Valid characters to make up these two strings are uppercase
+ letters A through Z, numerics 0 through 9, and the special
+ characters $, # and @. The first character of the name must NOT
+ be numeric. Each string must be a maximum length of 8 characters
+ with no embedded spaces and the strings are joined by a dot. "
+ ::= { nwAppnFwdLsEntry 7 }
+
+nwAppnFwdLsAdjCpType OBJECT-TYPE
+ SYNTAX INTEGER { endnode(1), networknode(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the adjacent node type. The following values are
+ valid: endnode(1), networknode(2). endnode(1) includes both
+ End Node and LEN node types."
+ DEFVAL { endnode }
+ ::= { nwAppnFwdLsEntry 8 }
+
+nwAppnFwdLsAutoActSupport OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether the link is automatically enabled when
+ a session is activated over the link. It is an error to set
+ this to yes(1) when nwAppnFwdLsCpCpSessSupp is set to yes(1). "
+ DEFVAL { no }
+ ::= { nwAppnFwdLsEntry 10 }
+
+nwAppnFwdLsLimitedRsrc OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether this link is to be deactivated when
+ there are no sessions using the link. If
+ nwAppnFwdLsCpCpSessSupp is yes, however, the link will
+ not be deactivated if CP-CP sessions are terminated.
+ Note also that a link over a non-switched port cannot
+ be configured as a limited resource."
+ DEFVAL { no }
+ ::= { nwAppnFwdLsEntry 11 }
+
+nwAppnFwdLsSscpSession OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Requests a host system to initiate sessions between its SSCP and
+ dependent LUs within APPN Routing Services. If set to yes,
+ then nwAppnFwdLsPuName is required. Note: once this parameter
+ is set along with other link station parameters associated with
+ a link station definition, it cannot be modified. In order to
+ change it, the link station definition itself must be deleted and
+ then redefined with the new parameter."
+ DEFVAL { no }
+ ::= { nwAppnFwdLsEntry 12 }
+
+nwAppnFwdLsPuName OBJECT-TYPE
+SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the name of the local PU if nwAppnFwdLsSscpSession is
+ set to yes. Valid characters are uppercase A through Z and
+ numerics 0 through 9. The name must start with an alphabetic
+ character. Note: once this parameter is set along with other
+ link station parameters associated with a link station definition,
+ it cannot be modified. In order to change it, the link station
+ definition itself must be deleted and then redefined with the new
+ parameter."
+ ::= { nwAppnFwdLsEntry 13 }
+
+nwAppnFwdLsBackLvlLenEN OBJECT-TYPE
+ SYNTAX INTEGER { no(1), xid3(2), xid0(3), noxid(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether or not the adjacent node is a back level
+ LEN Node. If so, specify the type of back level LEN node as
+ follows:
+
+ xid3(2) - supports XID-3 protocols, but does not include
+ Network Name control vector in the XID.
+
+ xid0(3) - Supports XID-0 protocols. Not valid if
+ nwAppnExtIfLocalLsRole is negotiable(1).
+
+ noxid(4) - Does not support XID protocols. Valid only if
+ nwAppnExtIfPortType is nonswitched(1) and not
+ valid if nwAppnExtIfLocalLsRole is negotiable(1).
+
+ If not no(1), then nwAppnFwdLsAdjCpName and nwAppnFwdLsIdNum
+ must be specified. "
+ DEFVAL { no }
+ ::= { nwAppnFwdLsEntry 14 }
+
+nwAppnFwdLsCpCpSessSupp OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether this link supports CP to CP sessions."
+ DEFVAL { yes }
+ ::= { nwAppnFwdLsEntry 16 }
+
+nwAppnFwdLsEffectCap OBJECT-TYPE
+ SYNTAX INTEGER (0..603979776)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies th maximum kilo bits per second rate (link speed)
+ for the link. "
+ ::= { nwAppnFwdLsEntry 17 }
+
+nwAppnFwdLsConnectCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the cost per connect time for the link. Zero is the
+ lowest cost and 255 is the largest cost."
+ ::= { nwAppnFwdLsEntry 18 }
+
+nwAppnFwdLsByteCost OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the cost per Byte for the link. Zero is the lowest
+ cost and 255 is the largest cost."
+ ::= { nwAppnFwdLsEntry 19 }
+
+nwAppnFwdLsSecurity OBJECT-TYPE
+ SYNTAX INTEGER { nonsecure(1), --X'01'
+ publicSwitchNw(32), --X'20'
+ undergroundCable(64), --X'40'
+ secureConduit(96), --X'60'
+ guardedConduit(128), --X'80'
+ encrypted(160), --X'A0'
+ guardedRadiation(192) --X'C0'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Security selections available for the link are as follows:
+
+ non-secure - specifies no security.
+ public switched - data flows over a public switched
+ network.
+ underground cable - data transmitted over a secure
+ underground cable.
+ secure conduit - line is secure conduit that is not
+ guarded.
+ guarded conduit - conduit that is protected against
+ physical tapping.
+ encrypted - encryption over the line.
+ guarded radiation - line is proected against physical
+ and radiation tapping. "
+ ::= { nwAppnFwdLsEntry 20 }
+
+nwAppnFwdLsPropDelay OBJECT-TYPE
+ SYNTAX INTEGER {
+ minimum(0), --X'00'
+ negligible(384), --X'4C'
+ terrestrial(9216), --X'71'
+ packetswitched(147456), --X'91'
+ long(294912), --X'99'
+ maximum(2013265920) --X'FF'
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the propagation delay which represents the relative
+ time it takes for a signal to travel the length of the link in
+ microseconds, with some of the more common default values
+ enumerated. The default times in parentheses are in microseconds.
+ These default values fall into the following ranges:
+
+ minimum - no propagation delay
+ negligible, lan - less than 480 microseconds
+ terrestrial, telephone - between 480 and 49,512
+ microseconds
+ packetswitched - between 49,512 and 245,760
+ microseconds
+ long, satellite - more than 245760 microseconds.
+ maximum - the maximum propagation delay. "
+ ::= { nwAppnFwdLsEntry 21 }
+
+nwAppnFwdLsUsrDef1 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 1. "
+ DEFVAL { 128 }
+ ::= { nwAppnFwdLsEntry 22 }
+
+nwAppnFwdLsUsrDef2 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 2. "
+ DEFVAL { 128 }
+ ::= { nwAppnFwdLsEntry 23 }
+
+nwAppnFwdLsUsrDef3 OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies user defined parameter 3. "
+ DEFVAL { 128 }
+ ::= { nwAppnFwdLsEntry 24 }
+
+nwAppnFwdLsTrgtPacingCount OBJECT-TYPE
+ SYNTAX INTEGER (0..32767)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Species the desired pacing window size for BINDs on this
+ transmission group. The number is a value between 0 and 32767
+ and is significant only when fixed bind pacing is being used."
+ DEFVAL { 7 }
+ ::= { nwAppnFwdLsEntry 25 }
+
+nwAppnFwdLsMaxSendBtu OBJECT-TYPE
+ SYNTAX INTEGER (99..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies maximum Message Unit (MU) size that can be sent."
+ DEFVAL { 2048 }
+ ::= { nwAppnFwdLsEntry 26 }
+
+nwAppnFwdLsNumActiveSession OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies total number of active sessions on this link.
+ This includes both end point sessions and intermediate sessions."
+ ::= { nwAppnFwdLsEntry 27 }
+
+nwAppnFwdLsdynamicLs OBJECT-TYPE
+ SYNTAX INTEGER { yes(1), no(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies whether this link station was dynamically
+ allocated (yes(1)) or whether the link station was defined by
+ the user (no(2))."
+ ::= { nwAppnFwdLsEntry 28 }
+
+nwAppnFwdLsStopType OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediate(1),
+ orderly(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the type of shutdown for a link. Once selected,
+ set disable in nwAppnFwdIfAdminStatus. The shutdown choices are
+ as follows:
+
+ immediate(1) causes the link station to disconnect
+ immediately without flushing remaining Message Unit (MU)s.
+ orderly(2) causes the link station to disconnect
+ after successfully flushing remaining Message Unit (MU)s. "
+ DEFVAL { orderly }
+ ::= { nwAppnFwdLsEntry 29 }
+
+nwAppnFwdLsPortNbr OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This link station port number corresponds to the index into
+ the nwAppnFwdIfTable and the nwAppnExtensionTable, which
+ together describe the port used by APPN Routing Services."
+ ::= { nwAppnFwdLsEntry 30 }
+
+nwAppnFwdLsDestAddr OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the destination address of the adjacent link station
+ depending on the media type. For token ring or ethernet ports,
+ the information is the 6 byte Destination MAC Address which
+ starts in byte 1 and ends in byte 6. For token ring ports,
+ the MAC address must be specified in non-canonical format.
+ For ethernet ports the MAC address must be specified in
+ canonical format. For frame relay, the address is a non-null
+ terminated string which is the ascii representation of the DLCI."
+ ::= { nwAppnFwdLsEntry 31 }
+
+nwAppnFwdLsDsap OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For a token ring or ethernet network, specifies the destination
+ SAP address associated with the adjacent link station. "
+ DEFVAL { '04'h }
+ ::= { nwAppnFwdLsEntry 32 }
+
+nwAppnFwdLsBlockNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This represents the 3 hexadecimal digit block number which
+ precedes the 5 digit id number in the 8 digit node id of the
+ adjacent node. The node id is used in XIDs and Alerts. The
+ block number identifies the product type. Both the block number
+ and id number combined, uniquely identify the adjacent node
+ within the installation network."
+ ::= { nwAppnFwdLsEntry 33 }
+
+nwAppnFwdLsIdNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(5))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This represents the 5 hexadecimal digit id number which follows
+ the 3 digit block number in the 8 digit node id of the adjacent
+ node. The node id is used in XIDs and Alerts. The id number
+ uniquely identifies the adjacent node within a product type
+ indicated by its block number. Both the block number and id number
+ combined, uniquely identify the adjacent node within the
+ installation network."
+ ::= { nwAppnFwdLsEntry 34 }
+
+
+
+-- APPN Forwarding Link Station Counter Table
+
+-- APPN Forwarding link station Counter Table
+-- This table contains the objects that specify Basic Link Unit (BLU) and
+-- byte counters for each configured adjacent link station.
+--
+nwAppnFwdLsCtrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnFwdLsCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains the Basic Link Unit (BLU) and byte
+ counters for each configured adjacent link station."
+ ::= { nwAppnFwdLsCounters 1 }
+
+nwAppnFwdLsCtrEntry OBJECT-TYPE
+ SYNTAX NwAppnFwdLsCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry indicates the Basic Link Unit (BLU) and byte
+ count for the configured adjacent link station for which the
+ entry exists. "
+
+ INDEX { nwAppnFwdLsCtrLsName }
+ ::= { nwAppnFwdLsCtrTable 1 }
+
+NwAppnFwdLsCtrEntry ::=
+ SEQUENCE {
+ nwAppnFwdLsCtrLsName DisplayString,
+ nwAppnFwdLsCtrAdminStatus INTEGER,
+ nwAppnFwdLsCtrReset INTEGER,
+ nwAppnFwdLsCtrOperationalTime TimeTicks,
+ nwAppnFwdLsCtrInBlus Counter,
+ nwAppnFwdLsCtrOutBlus Counter,
+ nwAppnFwdLsCtrFwdBlus Counter,
+ nwAppnFwdLsCtrFilteredBlus Counter,
+ nwAppnFwdLsCtrDiscardBlus Counter,
+ nwAppnFwdLsCtrAddrErrBlus Counter,
+ nwAppnFwdLsCtrLenErrBlus Counter,
+ nwAppnFwdLsCtrHdrErrBlus Counter,
+ nwAppnFwdLsCtrInBytes Counter,
+ nwAppnFwdLsCtrOutBytes Counter,
+ nwAppnFwdLsCtrFwdBytes Counter,
+ nwAppnFwdLsCtrFilteredBytes Counter,
+ nwAppnFwdLsCtrDiscardBytes Counter,
+ nwAppnFwdLsCtrHostInBlus Counter,
+ nwAppnFwdLsCtrHostOutBlus Counter,
+ nwAppnFwdLsCtrHostDiscardBlus Counter,
+ nwAppnFwdLsCtrHostInBytes Counter,
+ nwAppnFwdLsCtrHostOutBytes Counter,
+ nwAppnFwdLsCtrHostDiscardBytes Counter
+ }
+
+nwAppnFwdLsCtrLsName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the primary index into the link station
+ counter table. This index is the link station name. "
+ ::= { nwAppnFwdLsCtrEntry 1 }
+
+nwAppnFwdLsCtrAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the administrative state of the Basic Link Unit (BLU)
+ and byte counters on the link for which this entry exists.
+ enabled(3) causes these counters to reset and become active.
+ disabled(2) causes these counters to become inactive. "
+ ::= { nwAppnFwdLsCtrEntry 2 }
+
+nwAppnFwdLsCtrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the Basic Link Unit (BLU) and byte counters on the link
+ for which this entry exists. reset(2) resets the counters to 0.
+ nwAppnFwdLsCtrOperationalTime is also reset to 0."
+ ::= { nwAppnFwdLsCtrEntry 3 }
+
+nwAppnFwdLsCtrOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the amount of time in hundreths of a second that the
+ Basic Link Unit (BLU) and byte counters have been active on the
+ link for which this entry exists."
+ ::= { nwAppnFwdLsCtrEntry 4 }
+
+nwAppnFwdLsCtrInBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of Basic Link Unit (BLU)s that have
+ been received, during nwAppnFwdLsCtrOperationaltime, on the link
+ for which this entry exists. This includes both information
+ (I-frame) and XID BLUs."
+ ::= { nwAppnFwdLsCtrEntry 5 }
+
+nwAppnFwdLsCtrOutBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of Basic Link Unit (BLU)s that have
+ been transmitted, during nwAppnFwdLsCtrOperationalTime, on the
+ link for which this entry exists. This includes both information
+ (I-frame) and XID BLUs."
+ ::= { nwAppnFwdLsCtrEntry 6 }
+
+nwAppnFwdLsCtrFwdBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 7 }
+
+nwAppnFwdLsCtrFilteredBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 8 }
+
+nwAppnFwdLsCtrDiscardBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 9 }
+
+nwAppnFwdLsCtrAddrErrBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 10 }
+
+nwAppnFwdLsCtrLenErrBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of received Basic Link Unit (BLU)s
+ during nwAppnFwdLsCtrOperationalTime which have invalid DLC
+ headers on the link for which this entry exists."
+ ::= { nwAppnFwdLsCtrEntry 11 }
+
+nwAppnFwdLsCtrHdrErrBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of received Basic Link Unit (BLU)s
+ during nwAppnFwdLsCtrOperationalTime which have length errors
+ on the link for which this entry exists."
+ ::= { nwAppnFwdLsCtrEntry 12 }
+
+nwAppnFwdLsCtrInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of bytes that have been received,
+ during nwAppnFwdLsCtrOperationalTime, on the link for which
+ the entry exists. This includes bytes contained in
+ information (I-frames) and XID BLUs."
+ ::= { nwAppnFwdLsCtrEntry 13 }
+
+nwAppnFwdLsCtrOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the total number of bytes that have been transmitted,
+ during nwAppnFwdLsCtrOperationalTime, on the link for which the
+ entry exists. This includes bytes contained in information
+ (I-frames) and XID BLUs."
+ ::= { nwAppnFwdLsCtrEntry 14 }
+
+nwAppnFwdLsCtrFwdBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 15 }
+
+nwAppnFwdLsCtrFilteredBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 16 }
+
+nwAppnFwdLsCtrDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 17 }
+
+nwAppnFwdLsCtrHostInBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 18 }
+
+nwAppnFwdLsCtrHostOutBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 19 }
+
+nwAppnFwdLsCtrHostDiscardBlus OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 20 }
+
+nwAppnFwdLsCtrHostInBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 21 }
+
+nwAppnFwdLsCtrHostOutBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 22 }
+
+nwAppnFwdLsCtrHostDiscardBytes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnFwdLsCtrEntry 23 }
+
+-- Link State-Based Protocols
+-- This group contains the managed objects for Link State protocols for
+-- APPN Routing Services.
+
+-- APPN ISR System Group
+-- This group contains the managed objects for global, system-wide
+-- APPN Intermediate Session Routing (ISR) LinkState based routing protocol.
+
+-- APPN ISR System Configuration Parameters
+-- This group contains the objects that pertain to the setup and
+-- configuration of the APPN ISR LinkState based routing protocol.
+
+
+
+-- Link State-Based Protocols
+-- This group contains the objects that apply to the Link State based routing
+-- protocols supported by APPN Routing Services.
+
+-- APPN ISR System Group
+-- This group contains the objects that pertain to the APPN Intermediate Session
+-- Routing (ISR) LinkState-based routing protocol at a system-wide, global level.
+
+-- APPN ISR System Configuration Parameters
+-- This group contains the objects that pertain to the setup and configuration
+-- of the APPN ISR Link State based routing protocol at a system-wide, global level.
+
+
+nwAppnIsrAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disable(2), -- disable
+ enable(3) -- enable
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Intermediate Session Routing cannot be turned on and
+ off. Any modifications to this leaf will have no
+ affect. "
+ ::= { nwAppnIsrConfig 1 }
+
+nwAppnIsrOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- none of the following
+ disabled(2), -- inactive
+ enabled(3), -- active
+ pendingDisable(4), -- deactivate in progress
+ pendingEnable(5) -- activate in progress
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the current operating condition of the ISR routing
+ protocol, system-wide."
+ ::= { nwAppnIsrConfig 2 }
+
+nwAppnIsrAdminReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1) -- none of the following
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object does not apply to this protocol. It is a common
+ object, inherited from the MIB framework used to provide a
+ common management interface to all the Cabletron Routing Services
+ protocol-specific MIBs."
+ ::= { nwAppnIsrConfig 3 }
+
+nwAppnIsrOperationalTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the elapsed time, in hundredths of a second, that
+ nwAppnOperStatus has been in its current state."
+ ::= { nwAppnIsrConfig 4 }
+
+nwAppnIsrVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current revision level of the ISR firmware in
+ textual format. This is the same version number as that of APPN
+ Routing Services firmware, nwAppnSysVersion. "
+ ::= { nwAppnIsrConfig 5 }
+
+
+-- APPN Event Group
+nwAppnEventAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set the administrative state of APPN Routing Services event
+ logging. enabled(3) causes the event log to become active.
+ disabled(2) causes the event log to become inactive."
+ ::= { nwAppnEventLogConfig 1 }
+
+nwAppnEventMaxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets the maximum number of entries allowed in the event log
+ table. When the number of entries reaches the value of
+ nwAppnEventMaxEntries the first (oldest) entry is deleted
+ to allow a new entry to be added."
+ ::= { nwAppnEventLogConfig 2 }
+
+nwAppnEventTraceAll OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ disabled(2),
+ enabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "enabled(3) allows logging of all event types on all ports.
+ disabled(2) causes the filter table to specify which events to
+ log."
+ ::= { nwAppnEventLogConfig 3 }
+
+
+-- Event Log Filter Table
+-- The Event Log Filter Table contains the managed objects used to setup
+-- and configure event log filters for APPN Routing Services events.
+
+
+nwAppnEventFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnEventFilterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains descriptions of how to filter log entries."
+ ::= { nwAppnEventLogFilterTable 1 }
+
+nwAppnEventFilterEntry OBJECT-TYPE
+ SYNTAX NwAppnEventFilterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies the filter for log entries. The
+ instance nwAppnEventProtocol refers to the instance used
+ in the nwRtgProtocolTable and nwComponentTable specified
+ by the ctrouter-mib.txt. "
+ INDEX { nwAppnEventFltrProtocol, nwAppnEventFltrIfNum }
+ ::= { nwAppnEventFilterTable 1 }
+
+NwAppnEventFilterEntry ::=
+ SEQUENCE {
+ nwAppnEventFltrProtocol INTEGER,
+ nwAppnEventFltrIfNum INTEGER,
+ nwAppnEventFltrControl INTEGER,
+ nwAppnEventFltrType INTEGER,
+ nwAppnEventFltrSeverity INTEGER,
+ nwAppnEventFltrAction INTEGER
+ }
+
+nwAppnEventFltrProtocol OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Selects the protocol to log events from."
+ ::= { nwAppnEventFilterEntry 1 }
+
+nwAppnEventFltrIfNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the APPN Routing Services port on which to log events. "
+ ::= { nwAppnEventFilterEntry 2 }
+
+nwAppnEventFltrControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ delete(2),
+ add(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this field to delete will allow entries to be
+ removed from the table. This is done by adding new entries
+ with instance fields that match the entry to be removed from
+ the table. The new entry being added must have this control
+ field set to delete in order for the matching entry already
+ in the table to be deleted. Setting this field to add will
+ add the entry to the table."
+ ::= { nwAppnEventFilterEntry 3 }
+
+nwAppnEventFltrType OBJECT-TYPE
+ SYNTAX INTEGER {
+ misc(1),
+ timer(2),
+ rcv(4),
+ xmit(8),
+ event(16),
+ error(32)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This bit field mask filter will allow only events of
+ certain types to be logged. By default all types will be
+ logged. Clearing event types from this field will cause
+ those types not to be logged. Adding event types to this
+ field will enable those types to be logged. "
+ ::= { nwAppnEventFilterEntry 4 }
+
+nwAppnEventFltrSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ highest(1),
+ highmed(2),
+ highlow(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This filter controls the amount of logging by ignoring events
+ of lower priority than that specified by the filter value.
+ Specifying highest(1) causes all events except those of highest
+ severity to be ignored. Specifying highmed(2) causes lowest
+ severity events to be ignored. Specifying highlow(3) causes
+ all events to be logged. highmed(2) is the default setting."
+ ::= { nwAppnEventFilterEntry 5 }
+
+nwAppnEventFltrAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ log(1),
+ trap(2),
+ logTrap(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This field specifies how the events are to be logged.
+ Specifying log(1) stores the events in the event log
+ table (defined below). Specifying trap(2) sends events
+ out through the trap mechanism. Specifying logTrap(3)
+ does both. "
+ ::= { nwAppnEventFilterEntry 6 }
+
+-- Event Log Table
+-- The Event Log Table contains the logged events.
+
+nwAppnEventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NwAppnEventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains all events that have been logged."
+ ::= { nwAppnEventLogTable 1 }
+
+nwAppnEventEntry OBJECT-TYPE
+ SYNTAX NwAppnEventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Each entry specifies events that have been logged."
+ INDEX { nwAppnEventNumber }
+ ::= { nwAppnEventTable 1 }
+
+NwAppnEventEntry ::=
+ SEQUENCE {
+ nwAppnEventNumber INTEGER,
+ nwAppnEventTime TimeTicks,
+ nwAppnEventType INTEGER,
+ nwAppnEventSeverity INTEGER,
+ nwAppnEventProtocol INTEGER,
+ nwAppnEventIfNum INTEGER,
+ nwAppnEventTextString OCTET STRING
+ }
+
+nwAppnEventNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This ordinal number uniquely identifies events."
+ ::= { nwAppnEventEntry 1 }
+
+nwAppnEventTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This number specifies when the event was logged."
+ ::= { nwAppnEventEntry 2 }
+
+nwAppnEventType OBJECT-TYPE
+ SYNTAX INTEGER {
+ misc(1),
+ timer(2),
+ rcv(4),
+ xmit(8),
+ event(16),
+ diags(32),
+ error(64)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies type of event logged."
+ ::= { nwAppnEventEntry 3 }
+
+nwAppnEventSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ highest(1),
+ highmed(2),
+ highlow(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the severity of the event logged."
+ ::= { nwAppnEventEntry 4 }
+
+nwAppnEventProtocol OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the protocol where the event occured."
+ ::= { nwAppnEventEntry 5 }
+
+nwAppnEventIfNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the APPN Routing Services port the event occurred on."
+ ::= { nwAppnEventEntry 6 }
+
+nwAppnEventTextString OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the actual text string to be logged."
+ ::= { nwAppnEventEntry 7 }
+
+END