summaryrefslogtreecommitdiff
path: root/MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB')
-rw-r--r--MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB643
1 files changed, 643 insertions, 0 deletions
diff --git a/MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB b/MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB
new file mode 100644
index 0000000..c5629dc
--- /dev/null
+++ b/MIBS/edgeswitch/EdgeSwitch-BOXSERVICES-PRIVATE-MIB
@@ -0,0 +1,643 @@
+EdgeSwitch-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
+
+-- Broadcom Inc EdgeSwitch Box Services MIB
+-- Copyright Broadcom Inc(2004-2008) All rights reserved.
+
+-- This SNMP Management Information Specification
+-- embodies Broadcom Inc's confidential and proprietary
+-- intellectual property. Broadcom Inc retains all title
+-- and ownership in the Specification including any revisions.
+
+-- This Specification is supplied "AS IS", Broadcom Inc
+-- makes no warranty, either expressed or implied,
+-- as to the use, operation, condition, or performance of the
+-- Specification.
+
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Unsigned32, Integer32 FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION FROM SNMPv2-TC
+ DisplayString FROM RFC1213-MIB
+ fastPath FROM EdgeSwitch-REF-MIB;
+
+ fastPathBoxServices MODULE-IDENTITY
+ LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
+ ORGANIZATION "Broadcom Inc"
+ CONTACT-INFO ""
+
+ DESCRIPTION
+ "The Ubiquiti Private MIB for EdgeSwitch Box Services Feature."
+
+ -- Revision history.
+ REVISION
+ "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
+ DESCRIPTION
+ "Postal address updated."
+ REVISION
+ "200802220000Z" -- 22 Feb 2008 12:00:00 GMT
+ DESCRIPTION
+ "Ubiquiti branding related changes."
+
+ ::= { fastPath 43 }
+
+BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The temperature state"
+ SYNTAX INTEGER {
+ low(0),
+ normal(1),
+ warning(2),
+ critical(3),
+ shutdown(4),
+ notpresent(5),
+ notoperational(6)
+ }
+
+--**************************************************************************************
+-- boxServicesGroup
+--
+-- This group provides configuration and status of the Box Services
+-- feature.
+--
+--**************************************************************************************
+
+ boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
+
+ --**************************************************************************************
+ -- Some scalars
+
+ boxServicesNormalTempRangeMin OBJECT-TYPE
+ SYNTAX Integer32 (-100..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " Lower boundary of normal temperature range."
+ DEFVAL { 0 }
+ ::= { boxServicesGroup 1 }
+
+ boxServicesNormalTempRangeMax OBJECT-TYPE
+ SYNTAX Integer32 (-100..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " Upper boundary of normal temperature range."
+ DEFVAL { 45 }
+ ::= { boxServicesGroup 2 }
+
+ boxServicesTemperatureTrapEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
+ DEFVAL { enable }
+ ::= { boxServicesGroup 3 }
+
+ boxServicesPSMStateTrapEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " Enable or disable Power Supply Module state change trap."
+ DEFVAL { enable }
+ ::= { boxServicesGroup 4 }
+
+ boxServicesFanStateTrapEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " Enable or disable Fan state change trap."
+ DEFVAL { enable }
+ ::= { boxServicesGroup 5 }
+
+
+
+ boxServicesThermalShutdownSensor OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The number of the sensor which initiated thermal shutdown."
+
+ ::= { boxServicesGroup 13 }
+
+ boxServicesThermalShutdownTemperature OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The temperature of the sensor which initiated thermal shutdown."
+
+ ::= { boxServicesGroup 14 }
+
+ --**************************************************************************************
+ -- boxServicesFans
+
+ boxServicesFansTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoxServicesFansEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fan"
+ ::= { boxServicesGroup 6 }
+
+ boxServicesFansEntry OBJECT-TYPE
+ SYNTAX BoxServicesFansEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Box Services Fan Entry"
+ INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
+ ::= { boxServicesFansTable 1 }
+
+ BoxServicesFansEntry ::= SEQUENCE {
+ boxServicesFanUnitIndex
+ Unsigned32,
+ boxServicesFansIndex
+ Integer32,
+ boxServicesFanItemType
+ INTEGER,
+ boxServicesFanItemState
+ INTEGER,
+ boxServicesFanSpeed
+ OCTET STRING,
+ boxServicesFanDutyLevel
+ OCTET STRING
+ }
+
+ boxServicesFanUnitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unit index for an entry in the Box Services Fan Table"
+ ::= { boxServicesFansEntry 6 }
+
+ boxServicesFansIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique index of fan table entry"
+ ::= { boxServicesFansEntry 1 }
+
+ boxServicesFanItemType OBJECT-TYPE
+ SYNTAX INTEGER {
+ fixed(1),
+ removable(2),
+ fixedAC(3),
+ removableDC(4),
+ fixedDC(5),
+ removableAC(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of fan"
+ ::= { boxServicesFansEntry 2 }
+
+
+ boxServicesFanItemState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notpresent(1),
+ operational(2),
+ failed(3),
+ powering(4),
+ nopower(5),
+ notpowering(6),
+ incompatible(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
+ ::= { boxServicesFansEntry 3 }
+
+
+ boxServicesFanSpeed OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (13))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed of fan"
+ ::= { boxServicesFansEntry 4}
+
+ boxServicesFanDutyLevel OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (13))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The duty level of fan, in percents"
+ ::= { boxServicesFansEntry 5}
+
+
+ --**************************************************************************************
+ -- boxServicesPowSupplies
+
+ boxServicesPowSuppliesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Power supply"
+ ::= { boxServicesGroup 7 }
+
+ boxServicesPowSuppliesEntry OBJECT-TYPE
+ SYNTAX BoxServicesPowSuppliesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Box Services Power Supply Entry"
+ INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
+ ::= { boxServicesPowSuppliesTable 1 }
+
+ BoxServicesPowSuppliesEntry ::= SEQUENCE {
+ boxServicesPowerSuppUnitIndex
+ Unsigned32,
+ boxServicesPowSupplyIndex
+ Integer32,
+ boxServicesPowSupplyItemType
+ INTEGER,
+ boxServicesPowSupplyItemState
+ INTEGER
+ }
+
+ boxServicesPowerSuppUnitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unit index for an entry in the Box Services Power Supply Table"
+ ::= { boxServicesPowSuppliesEntry 4 }
+
+ boxServicesPowSupplyIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique index of power supply table entry"
+ ::= { boxServicesPowSuppliesEntry 1 }
+
+ boxServicesPowSupplyItemType OBJECT-TYPE
+ SYNTAX INTEGER {
+ fixed(1),
+ removable(2),
+ fixedAC(3),
+ removableDC(4),
+ fixedDC(5),
+ removableAC(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of power supply"
+ ::= { boxServicesPowSuppliesEntry 2 }
+
+
+ boxServicesPowSupplyItemState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notpresent(1),
+ operational(2),
+ failed(3),
+ powering(4),
+ nopower(5),
+ notpowering(6),
+ incompatible(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
+ incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
+ ::= { boxServicesPowSuppliesEntry 3 }
+
+
+
+ --**************************************************************************************
+ -- boxServicesTempSensors
+
+
+ boxServicesTempSensorsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Temperature sensor"
+ ::= { boxServicesGroup 8 }
+
+
+ boxServicesTempSensorsEntry OBJECT-TYPE
+ SYNTAX BoxServicesTempSensorsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Box Services Temperature Sensor Entry"
+ INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
+ ::= { boxServicesTempSensorsTable 1 }
+
+ BoxServicesTempSensorsEntry ::= SEQUENCE {
+ boxServicesUnitIndex
+ Unsigned32,
+ boxServicesTempSensorIndex
+ Unsigned32,
+ boxServicesTempSensorType
+ INTEGER,
+ boxServicesTempSensorState
+ BoxsTemperatureStatus,
+ boxServicesTempSensorTemperature
+ Integer32
+ }
+
+ boxServicesUnitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unit index for an entry in the Box Services Temperature Sensor Table"
+ ::= { boxServicesTempSensorsEntry 1 }
+
+ boxServicesTempSensorIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique index of temperature sensor table entry"
+ ::= { boxServicesTempSensorsEntry 2 }
+
+
+ boxServicesTempSensorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ fixed(1),
+ removable(2),
+ fixedAC(3),
+ removableDC(4),
+ fixedDC(5),
+ removableAC(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of temperature sensor"
+ ::= { boxServicesTempSensorsEntry 3 }
+
+
+ boxServicesTempSensorState OBJECT-TYPE
+ SYNTAX BoxsTemperatureStatus
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The state of temperature sensor"
+ ::= { boxServicesTempSensorsEntry 4 }
+
+
+ boxServicesTempSensorTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature value reported by sensor"
+ ::= { boxServicesTempSensorsEntry 5 }
+
+ boxServicesTempUnitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Temperature status table"
+ ::= { boxServicesGroup 15 }
+
+ boxServicesTempUnitEntry OBJECT-TYPE
+ SYNTAX BoxServicesTempUnitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Box Services Temperature Unit Entry"
+ INDEX { boxServicesTempUnitIndex }
+ ::= { boxServicesTempUnitTable 1 }
+
+ BoxServicesTempUnitEntry ::= SEQUENCE {
+ boxServicesTempUnitIndex
+ Unsigned32,
+ boxServicesTempUnitState
+ BoxsTemperatureStatus,
+ boxServicesTempUnitTemperature
+ Integer32
+ }
+
+ boxServicesTempUnitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unit index for an entry in the Box Services Temperature Unit Table"
+ ::= { boxServicesTempUnitEntry 1 }
+
+ boxServicesTempUnitState OBJECT-TYPE
+ SYNTAX BoxsTemperatureStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature state of the unit"
+ ::= { boxServicesTempUnitEntry 2 }
+
+ boxServicesTempUnitTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The highest temperature currently reported by any sensor on the unit"
+ ::= { boxServicesTempUnitEntry 3 }
+
+--**************************************************************************************
+-- boxServicesNotificationsGroup
+--
+-- This group provides notification definitions for the Box Services
+-- feature.
+--
+--**************************************************************************************
+
+ boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
+
+ --**************************************************************************************
+ -- boxServices notification definitions
+
+ boxsItemStateChangeEvent OBJECT-TYPE
+ SYNTAX INTEGER {
+ insertion(1),
+ removal(2),
+ becomeoperational(3),
+ failure(4),
+ losepower(5)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This event describes states of the fan or power supply.
+
+ insertion - hot-pluggable fan or power supply was inserted
+ removal - hot-pluggable fan or power supply was removed
+ becomeoperational - fan or power supply became operational after failure state
+ failure - fan or power supply failure happened, i.e. it is not able to perform its functions
+ losepower - a power supply was operational, but the power to it has been disconnected or has failed"
+ ::= { boxServicesNotificationsGroup 1 }
+
+ boxsTemperatureChangeEvent OBJECT-TYPE
+ SYNTAX INTEGER {
+ abovethreshold(1),
+ belowthreshold(2),
+ withinnormalrange(3)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This event describes change of the temperature.
+ To avoid flipping on boundary conditions, it is allowed to send the trap
+ taking into account some margin around thresholds.
+
+ abovethreshold - temperature increased and crossed upper threshold value
+ belowthreshold - temperature decreased and crossed lower threshold value
+ withinnormalrange - temperature returned to normal range (between threshold)"
+ ::= { boxServicesNotificationsGroup 2 }
+
+ boxsTemperatureStatusCurrentEvent OBJECT-TYPE
+ SYNTAX BoxsTemperatureStatus
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This event describes the current status of a switch."
+ ::= { boxServicesNotificationsGroup 3 }
+
+ boxsTemperatureStatusPreviousEvent OBJECT-TYPE
+ SYNTAX BoxsTemperatureStatus
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This event describes the previous status of a switch."
+ ::= { boxServicesNotificationsGroup 4 }
+
+
+
+--**************************************************************************************
+-- Traps
+--**************************************************************************************
+
+ fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
+
+
+
+ boxsFanStateChange NOTIFICATION-TYPE
+ OBJECTS {
+ boxServicesFansIndex,
+ boxsItemStateChangeEvent
+ }
+ STATUS current
+ DESCRIPTION
+ "Trap is sent when fan state change happens."
+ ::= { fastPathBoxServicesTraps 1 }
+
+ boxsPowSupplyStateChange NOTIFICATION-TYPE
+ OBJECTS {
+ boxServicesPowSupplyIndex,
+ boxsItemStateChangeEvent
+ }
+ STATUS current
+ DESCRIPTION
+ "Trap is sent when power supply state change happens."
+ ::= { fastPathBoxServicesTraps 2 }
+
+
+ boxsTemperatureChange NOTIFICATION-TYPE
+ OBJECTS {
+ boxServicesTempSensorIndex,
+ boxsTemperatureChangeEvent
+ }
+ STATUS obsolete
+ DESCRIPTION
+ "Trap is sent when temperature is changing and crossing any of the thresholds"
+ ::= { fastPathBoxServicesTraps 3 }
+
+
+ boxsThermalShutdown NOTIFICATION-TYPE
+ OBJECTS {
+ boxServicesThermalShutdownSensor,
+ boxServicesThermalShutdownTemperature
+ }
+ STATUS current
+ DESCRIPTION
+ "Trap is sent when thermal shutdown is initiated."
+ ::= { fastPathBoxServicesTraps 4 }
+
+
+ boxsTemperatureStateChange NOTIFICATION-TYPE
+ OBJECTS {
+ boxServicesTempUnitIndex,
+ boxsTemperatureStatusCurrentEvent,
+ boxsTemperatureStatusPreviousEvent
+ }
+ STATUS current
+ DESCRIPTION
+ "Trap is sent when the system temperature crosses a threshold.
+ To avoid rapid flapping between states, a hysteresis may
+ be applied."
+ ::= { fastPathBoxServicesTraps 5 }
+
+--**************************************************************************************
+-- Locator LED manage group
+--
+-- This group provides manage definitions for the Locator LED feature.
+--
+--**************************************************************************************
+
+ boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }
+
+ boxsLocatorLedUnit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Spesifies unit number where Locator LED should blink on.
+ This is write-only value. It always returns '0' on request
+ if the Locator Led feature is supported."
+ ::= { boxsLocatorLedConfigGroup 1 }
+
+ boxsLocatorLedTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates time period in seconds for Locator LED blinking.
+ The range is from 20 to 3600 seconds.
+ The dafault value is 20 seconds.
+ This is write-only value. It always returns '0' on request
+ if the Locator Led feature is supported."
+ DEFVAL { 20 }
+ ::= { boxsLocatorLedConfigGroup 2 }
+
+ boxsLocatorLedEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0),
+ enable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Starts the Locator LED blinking.
+ If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
+ If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
+ This is write-only value. It always returns '0' on request
+ if the Locator Led feature is supported."
+ ::= { boxsLocatorLedConfigGroup 3 }
+
+END