diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/dell/DELL-RAC-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/dell/DELL-RAC-MIB')
| -rw-r--r-- | MIBS/dell/DELL-RAC-MIB | 7229 |
1 files changed, 7229 insertions, 0 deletions
diff --git a/MIBS/dell/DELL-RAC-MIB b/MIBS/dell/DELL-RAC-MIB new file mode 100644 index 0000000..dd2f031 --- /dev/null +++ b/MIBS/dell/DELL-RAC-MIB @@ -0,0 +1,7229 @@ +-- +-- Dell Remote Access Controller (RAC) and Chassis Management Controller (CMC) +-- Management Information Base +-- +-- This MIB is the legacy iDRAC MIB. Changes are no longer made to this MIB +-- for iDRACs. iDRACs don't support all of the objects and traps defined +-- in this MIB. There is a new and more extensive iDRAC MIB available for +-- newer iDRACs (iDRAC7 and newer). +-- +-- This MIB is also the CMC MIB. Changes are made to this MIB only for CMCs now. +-- +-- Copyright (c) 2017 Dell Inc. +-- +-- Last Changed Revision: 19 +-- Last Changed Date: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017) +-- Text Last Updated: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017) +-- + +DELL-RAC-MIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises, TimeTicks + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215 + DisplayString + FROM RFC1213-MIB; + +-- text convention ------------------------------------------------------------------------ + + ------------------------------------------------------------------------------- + -- This data type is used to model textual information taken + -- from the NVT ASCII character set. By convention, objects + -- with this syntax are declared as having + -- SIZE (0..1023) + ------------------------------------------------------------------------------- + DellString ::= DisplayString (SIZE (0..1023)) + + DellRacType ::= INTEGER + { + other(1), -- the DRAC type is not one of the following + unknown(2), -- the DRAC type is unknown + dracIII(3), -- Drac III + era(4), -- ERA + drac4(5), -- Drac 4 + drac5(6), -- Drac 5 + drac5MC(7), -- Drac 5/MC + cmc(8), -- CMC + idrac(9), -- iDRAC + idrac7monolithic(16), -- iDRAC7 Monolithic + idrac7modular(17), -- iDRAC7 Modular + vrtxCMC(18), -- VRTX CMC + fx2CMC(19), -- FX2 Family CMC + idrac8monolithic(32), -- iDRAC8 Monolithic + idrac8modular(33) -- iDRAC8 Modular + } + + DellStatus ::= INTEGER + { + other(1), -- the status of the object is not one of the following: + unknown(2), -- the status of the object is unknown + -- (not known or monitored) + ok(3), -- the status of the object is ok + nonCritical(4), -- the status of the object is warning, non-critical + critical(5), -- the status of the object is critical (failure) + nonRecoverable(6) -- the status of the object is non-recoverable (dead) + } + + ------------------------------------------------------------------------------- + -- DellPowerReading is a string representation of a floating point value, + -- having exactly 3 digits of precision, and a maximum of 31 characters. + -- + -- DellChassisPowerIndexRange defines the possible chassis power instances + -- in this MIB. + -- + -- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU) + -- instances, per chassis power instance, in this MIB. + -- + -- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring + -- capabilities. + -- + -- DellTemperatureReading is an integer value, expressed in degrees Celsius. + ------------------------------------------------------------------------------- + DellPowerReading ::= DisplayString (SIZE (0..32)) + + DellCMCPowerIndexRange ::= INTEGER (1..1) + + DellCMCPSUIndexRange ::= INTEGER (1..6) + + DellCMCPSUCapable ::= INTEGER + { + absent(1), -- power supply is not present + none(2), -- no power monitoring abilities + basic(3) -- basic power monitoring abilities + } + + DellTemperatureReading ::= INTEGER + + ------------------------------------------------------------------------------- + -- DellTimestamp is defined in the displayable format: + -- + -- yyyymmddHHMMSS.uuuuuuDooo + -- + -- where yyyy is the year, mm is the month number, dd is the day of the month, + -- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the + -- number of microseconds, D is the UTC offset direction, and ooo is the + -- offset from UTC, in minutes. + -- + -- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC. + -- + -- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT + -- would be represented as: 19940525133015.000000-300 + ------------------------------------------------------------------------------- + DellTimestamp ::= DisplayString (SIZE (26)) + + ------------------------------------------------------------------------------- + -- DellCMCServerIndexRange defines the possible chassis server instances + -- in this MIB. + -- + -- DellCMCServerCapable is an enumeration of server presence and/or monitoring + -- capabilities. + ------------------------------------------------------------------------------- + DellCMCServerIndexRange ::= INTEGER (1..32) + + DellCMCServerCapable ::= INTEGER + { + absent(1), -- server is not present + none(2), -- no server monitoring abilities + basic(3), -- basic server monitoring abilities + off(4) -- server is powered off + } + + DellCMCServerStorageMode ::= INTEGER + { + notApplicable(1), -- not applicable to server + joined(2), -- storage mode is Joined + splitDualHost(3), -- storage mode is Split Dual Host + splitSingleHost(4), -- storage mode is Split Single Host + unknown(99) -- storage mode is unknown + } + + DellCMCServerIntrusionState ::= INTEGER + { + notApplicable(1), -- not applicable to server + closed(2), -- intrusion state is Closed + open(3), -- intrusion state is Open + unknown(99) -- intrusion state is unknown + } + + +-- MIB Objects and Tables -------------------------------------------------------- + + dell OBJECT IDENTIFIER ::= { enterprises 674 } + server3 OBJECT IDENTIFIER ::= { dell 10892 } + drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 } + drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 } + drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 } + drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 } + + drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 } + + drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 } + drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 } + drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 } + drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 } + + drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 } + + DrsCMCPowerTableEntry ::= SEQUENCE + { + drsChassisIndex DellCMCPowerIndexRange, + drsPotentialPower DellPowerReading, + drsIdlePower DellPowerReading, + drsMaxPowerSpecification DellPowerReading, + drsPowerSurplus DellPowerReading, + drsKWhCumulative DellPowerReading, + drsKWhCumulativeTime DellTimestamp, + drsWattsPeakUsage DellPowerReading, + drsWattsPeakTime DellTimestamp, + drsWattsMinUsage DellPowerReading, + drsWattsMinTime DellTimestamp, + drsWattsResetTime DellTimestamp, + drsWattsReading DellPowerReading, + drsAmpsReading DellPowerReading + } + + DrsCMCPSUTableEntry ::= SEQUENCE + { + drsPSUChassisIndex DellCMCPowerIndexRange, + drsPSUIndex DellCMCPSUIndexRange, + drsPSULocation DellString, + drsPSUMonitoringCapable DellCMCPSUCapable, + drsPSUVoltsReading DellPowerReading, + drsPSUAmpsReading DellPowerReading, + drsPSUWattsReading DellPowerReading + } + + drsChassisServerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5 } + + DrsCMCServerTableEntry ::= SEQUENCE + { + drsServerIndex DellCMCServerIndexRange, + drsServerMonitoringCapable DellCMCServerCapable, + drsServerServiceTag DellString, + drsServerSlotName DellString, + drsServerSlotNumber DellString, + drsServerNodeID DellString, + drsServerModel DellString, + drsServerAssetTag DellString, + drsServerNumStorageControllers INTEGER, + drsServerStorageMode DellCMCServerStorageMode, + drsServerIntrusionState DellCMCServerIntrusionState, + drsServerAssignedServerSlots DellString + } + +-- Storage details start +storageDetailsGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 6 } +software OBJECT IDENTIFIER ::= { storageDetailsGroup 1 } +storageManagement OBJECT IDENTIFIER ::= { software 20 } +physicalDevices OBJECT IDENTIFIER ::= { storageManagement 130 } +logicalDevices OBJECT IDENTIFIER ::= { storageManagement 140 } + + +------------------------------------------------------------------------------ +-- Textual Conventions +------------------------------------------------------------------------------ + +FQDDString ::= DisplayString (SIZE (0..512)) + +ObjectStatusEnum ::= INTEGER { + other(1), -- the status of the object is not one of the + -- following: + unknown(2), -- the status of the object is unknown + -- (not known or monitored) + ok(3), -- the status of the object is ok + nonCritical(4), -- the status of the object is warning, non-critical + critical(5), -- the status of the object is critical (failure) + nonRecoverable(6) -- the status of the object is non-recoverable (dead) +} +BooleanType ::= INTEGER (0..1) -- 0 = FALSE, 1 = TRUE + + +-- Storage details end + + + drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 } + drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 } + drsCMCAlert2Group OBJECT IDENTIFIER ::= { drsOutofBandGroup 21 } + drsChassisAlert2Variables OBJECT IDENTIFIER ::= { drsCMCAlert2Group 10 } + + drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 } + drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 } + + +-- Variables and Traps ------------------------------------------------------------------------ + + ------------------------------------------------------------------------------- + -- group: product information + ------------------------------------------------------------------------------- + + drsProductName OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller." + ::= { drsProductInfoGroup 1 } + + drsProductShortName OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. " + ::= { drsProductInfoGroup 2 } + + drsProductDescription OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. " + ::= { drsProductInfoGroup 3 } + + drsProductManufacturer OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. " + ::= { drsProductInfoGroup 4 } + + drsProductVersion OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. " + ::= { drsProductInfoGroup 5 } + + drsChassisServiceTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. " + ::= { drsProductInfoGroup 6 } + + drsProductURL OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. " + ::= { drsProductInfoGroup 7 } + + drsProductChassisAssetTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. " + ::= { drsProductInfoGroup 8 } + + drsProductChassisLocation OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. " + ::= { drsProductInfoGroup 9 } + + drsProductChassisName OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. " + ::= { drsProductInfoGroup 10 } + + drsSystemServiceTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. " + ::= { drsProductInfoGroup 11 } + + drsProductSystemAssetTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. " + ::= { drsProductInfoGroup 12 } + + drsProductSystemSlot OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. " + ::= { drsProductInfoGroup 13 } + + drsProductType OBJECT-TYPE + SYNTAX DellRacType + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card " + ::= { drsProductInfoGroup 14 } + + drsProductChassisDataCenter OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0015 This attribute defines the Data Center locator of the chassis. " + ::= { drsProductInfoGroup 15 } + + drsProductChassisAisle OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0016 This attribute defines the Aisle locator of the chassis. " + ::= { drsProductInfoGroup 16 } + + drsProductChassisRack OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0017 This attribute defines the Rack locator of the chassis. " + ::= { drsProductInfoGroup 17 } + + drsProductChassisRackSlot OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. " + ::= { drsProductInfoGroup 18 } + + drsProductChassisModel OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0019 This attribute defines the Model of the chassis." + ::= { drsProductInfoGroup 19 } + + drsProductChassisExpressServiceCode OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0020 This attribute defines the Express Service Code of the chassis." + ::= { drsProductInfoGroup 20 } + + drsProductChassisSystemID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0021 This attribute defines the System ID of the chassis." + ::= { drsProductInfoGroup 21 } + + drsProductChassisSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0001.0022 This attribute defines the size of the + chassis in rack units (U). A U is a standard unit of + measure for the height of a rack or rack-mountable component." + ::= { drsProductInfoGroup 22 } + + ------------------------------------------------------------------------------- + -- group: firmware + ------------------------------------------------------------------------------- + + drsFirmwareVersion OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of chassis management controller 1." + ::= { drsFirmwareGroup 1 } + + drsiKVMFirmwareVersion OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0002.0002 This attribute defines the firmware version of the iKVM. " + ::= { drsFirmwareGroup 2 } + + drsFirmwareVersion2 OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0001.0002.0003 This attribute defines the firmware version of chassis management controller 2." + ::= { drsFirmwareGroup 3 } + + ------------------------------------------------------------------------------- + -- group: chassis status + ------------------------------------------------------------------------------- + + drsGlobalSystemStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status + being monitored by the chassis management card." + ::= { drsStatusGroup 1 } + + drsGlobalCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 1 } + + drsIOMCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 2 } + + drsKVMCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 3 } + + drsRedCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 4 } + + drsPowerCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 5 } + + drsFanCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 6 } + + drsBladeCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 7 } + + drsTempCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 8 } + + drsCMCCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status + being monitored by the chassis management card." + ::= { drsStatusNowGroup 9 } + + drsChassisFrontPanelAmbientTemperature OBJECT-TYPE + SYNTAX DellTemperatureReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0010 This attribute defines the ambient temperature + reading (in degrees Celsius) for the chassis front panel controller." + ::= { drsStatusNowGroup 10 } + + drsCMCAmbientTemperature OBJECT-TYPE + SYNTAX DellTemperatureReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0011 This attribute defines the ambient temperature + reading (in degrees Celsius) for the chassis management card." + ::= { drsStatusNowGroup 11 } + + drsCMCProcessorTemperature OBJECT-TYPE + SYNTAX DellTemperatureReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0012 This attribute defines the temperature reading + (in degrees Celsius) for the chassis management card processor." + ::= { drsStatusNowGroup 12 } + + drsGlobalPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 1 } + + drsIOMPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 2 } + + drsKVMPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 3 } + + drsRedPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 4 } + + drsPowerPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 5 } + + drsFanPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status + being monitored by the chassis management card." + ::= { drsStatusPrevGroup 6 } + + drsBladePrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status + recorded by the chassis management card." + ::= { drsStatusPrevGroup 7 } + + drsTempPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status + being monitored by the chassis management card." + ::= { drsStatusPrevGroup 8 } + + drsCMCPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status + being monitored by the chassis management card." + ::= { drsStatusPrevGroup 9 } + + drsGlobalChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent + global status change." + ::= { drsStatusChangeGroup 1 } + + drsIOMChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent + IOM status change." + ::= { drsStatusChangeGroup 2 } + + drsKVMChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent + iKVM status change." + ::= { drsStatusChangeGroup 3 } + + drsRedChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent + Redundancy status change." + ::= { drsStatusChangeGroup 4 } + + drsPowerChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent + power health status change." + ::= { drsStatusChangeGroup 5 } + + drsFanChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent + Fan health status change." + ::= { drsStatusChangeGroup 6 } + + drsBladeChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent + Blade health status change." + ::= { drsStatusChangeGroup 7 } + + drsTempChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent + Temp Sensor health status change." + ::= { drsStatusChangeGroup 8 } + + drsCMCChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent + CMC health status change." + ::= { drsStatusChangeGroup 9 } + + ------------------------------------------------------------------------------- + -- group: chassis power + ------------------------------------------------------------------------------- + + drsCMCPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF DrsCMCPowerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0004.0001 This object defines the CMC power table." + ::= { drsChassisPowerGroup 1 } + + drsCMCPowerTableEntry OBJECT-TYPE + SYNTAX DrsCMCPowerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry." + INDEX { drsChassisIndex } + ::= { drsCMCPowerTable 1 } + + drsCMCPSUTable OBJECT-TYPE + SYNTAX SEQUENCE OF DrsCMCPSUTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0004.0002 This object defines the CMC PSU table." + ::= { drsChassisPowerGroup 2 } + + drsCMCPSUTableEntry OBJECT-TYPE + SYNTAX DrsCMCPSUTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry." + INDEX { drsPSUChassisIndex, drsPSUIndex } + ::= { drsCMCPSUTable 1 } + + ------------------------------------------------------------------------------- + -- table: CMC power information + ------------------------------------------------------------------------------- + + drsChassisIndex OBJECT-TYPE + SYNTAX DellCMCPowerIndexRange + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0001 This attribute defines the index + (one-based) of the associated chassis." + ::= { drsCMCPowerTableEntry 1 } + + drsPotentialPower OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by + the chassis infrastructure, plus the sum of the maximum power requirements + for all currently powered-on servers." + ::= { drsCMCPowerTableEntry 2 } + + drsIdlePower OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by + the chassis infrastructure, plus the sum of the minimum power requirements + for all currently powered-on servers." + ::= { drsCMCPowerTableEntry 3 } + + drsMaxPowerSpecification OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts) + at which server throttling will take place." + ::= { drsCMCPowerTableEntry 4 } + + + drsPowerSurplus OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts) + remaining above the drsPotentialPower reading." + ::= { drsCMCPowerTableEntry 5 } + + drsKWhCumulative OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power + usage (in KWh) since last reset." + ::= { drsCMCPowerTableEntry 6 } + + drsKWhCumulativeTime OBJECT-TYPE + SYNTAX DellTimestamp + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent + chassis power accumulator reset." + ::= { drsCMCPowerTableEntry 7 } + + drsWattsPeakUsage OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power + usage (in Watts) since last reset." + ::= { drsCMCPowerTableEntry 8 } + + drsWattsPeakTime OBJECT-TYPE + SYNTAX DellTimestamp + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent + chassis peak power usage." + ::= { drsCMCPowerTableEntry 9 } + + drsWattsMinUsage OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power + usage (in Watts) since last reset." + ::= { drsCMCPowerTableEntry 10 } + + drsWattsMinTime OBJECT-TYPE + SYNTAX DellTimestamp + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent + chassis minimum power usage." + ::= { drsCMCPowerTableEntry 11 } + + drsWattsResetTime OBJECT-TYPE + SYNTAX DellTimestamp + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent + reset of the chassis min/peak Watts readings." + ::= { drsCMCPowerTableEntry 12 } + + drsWattsReading OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power + usage (in Watts)." + ::= { drsCMCPowerTableEntry 13 } + + drsAmpsReading OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current + usage (in Watts)." + ::= { drsCMCPowerTableEntry 14 } + + ------------------------------------------------------------------------------- + -- table: CMC PSU info + ------------------------------------------------------------------------------- + + drsPSUChassisIndex OBJECT-TYPE + SYNTAX DellCMCPowerIndexRange + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0001 This attribute defines the index + (one-based) of the associated chassis." + ::= { drsCMCPSUTableEntry 1 } + + drsPSUIndex OBJECT-TYPE + SYNTAX DellCMCPSUIndexRange + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0002 This attribute defines the index + (one-based) of the associated CMC PSU." + ::= { drsCMCPSUTableEntry 2 } + + drsPSULocation OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0003 This attribute defines the location + of the CMC PSU." + ::= { drsCMCPSUTableEntry 3 } + + drsPSUMonitoringCapable OBJECT-TYPE + SYNTAX DellCMCPSUCapable + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring + capabilities, or the absence of a PSU in this location." + ::= { drsCMCPSUTableEntry 4 } + + drsPSUVoltsReading OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous + PSU Voltage reading." + ::= { drsCMCPSUTableEntry 5 } + + drsPSUAmpsReading OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous + PSU Current reading." + ::= { drsCMCPSUTableEntry 6 } + + drsPSUWattsReading OBJECT-TYPE + SYNTAX DellPowerReading + ACCESS read-only + STATUS mandatory + DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous + PSU Wattage reading." + ::= { drsCMCPSUTableEntry 7 } + + ------------------------------------------------------------------------------- + -- group: chassis servers + ------------------------------------------------------------------------------- + + drsCMCServerTable OBJECT-TYPE + SYNTAX SEQUENCE OF DrsCMCServerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0005.0001 This object defines the CMC server table." + ::= { drsChassisServerGroup 1 } + + drsCMCServerTableEntry OBJECT-TYPE + SYNTAX DrsCMCServerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION "0005.0001.0001 This object defines the CMC server table entry." + INDEX { drsServerIndex } + ::= { drsCMCServerTable 1 } + + ------------------------------------------------------------------------------- + -- table: CMC Server info + ------------------------------------------------------------------------------- + + drsServerIndex OBJECT-TYPE + SYNTAX DellCMCServerIndexRange + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0001 This attribute defines the index + (one-based) of the associated CMC server." + ::= { drsCMCServerTableEntry 1 } + + drsServerMonitoringCapable OBJECT-TYPE + SYNTAX DellCMCServerCapable + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0002 This attribute defines the server monitoring + capabilities, or the absence of a server in this location." + ::= { drsCMCServerTableEntry 2 } + + drsServerServiceTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0003 This attribute defines the Service Tag + of the CMC server." + ::= { drsCMCServerTableEntry 3 } + + drsServerSlotName OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0004 This attribute defines the Slot Name + of the CMC server." + ::= { drsCMCServerTableEntry 4 } + + drsServerSlotNumber OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0005 This attribute defines the Chassis + Slot Number of the CMC server." + ::= { drsCMCServerTableEntry 5 } + + drsServerNodeID OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0006 This attribute defines the Node ID + of the CMC server. The Node ID provides a unique identifier + for the server." + ::= { drsCMCServerTableEntry 6 } + + drsServerModel OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0007 This attribute defines the Model + of the CMC server." + ::= { drsCMCServerTableEntry 7 } + + drsServerAssetTag OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0008 This attribute defines the Asset Tag + of the CMC server." + ::= { drsCMCServerTableEntry 8 } + + drsServerNumStorageControllers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0009 This attribute defines the number of + storage controllers on the storage sled. The value + will be zero if this is not a storage sled." + ::= { drsCMCServerTableEntry 9 } + + drsServerStorageMode OBJECT-TYPE + SYNTAX DellCMCServerStorageMode + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0010 This attribute defines the Storage + Mode of the storage sled." + ::= { drsCMCServerTableEntry 10 } + + drsServerIntrusionState OBJECT-TYPE + SYNTAX DellCMCServerIntrusionState + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0011 This attribute defines the Intrusion + State of the CMC server if supported by the server." + ::= { drsCMCServerTableEntry 11 } + + drsServerAssignedServerSlots OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0005.0001.0001.0012 This attribute defines the the server + slots to which a storage sled is assigned. If this is + a storage sled that is assigned to one more or more + server slots, the value will be a comma-separated list + of one or more server slot names. If the storage sled + is not assigned to a server slot, the value will be an + empty string. If this is not a storage sled, the value + will be N/A." + ::= { drsCMCServerTableEntry 12 } + +------------------------------------------------------------------------------- +-- Storage Details Group +-- +-- OID Format: 1.3.6.1.4.1.674.10892.5.5 +------------------------------------------------------------------------------- + + +------------------------------------------------------------------------------- +-- Battery Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.<a>.<i1> +------------------------------------------------------------------------------- + +BatteryTableEntry ::=SEQUENCE { + batteryNumber INTEGER, + batteryState INTEGER, + batteryComponentStatus ObjectStatusEnum, + batteryPredictedCapacity INTEGER, + batteryFQDD DisplayString, + batteryDisplayName DisplayString +} + +batteryTable OBJECT-TYPE + SYNTAX SEQUENCE OF BatteryTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed batteries. The number of + entries is related to number of Batteries + discovered in the system. The maximum number of entries + is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 15 } + +batteryTableEntry OBJECT-TYPE + SYNTAX BatteryTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the battery table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { batteryNumber } + ::= { batteryTable 1 } + +batteryNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this battery entry. + " + ::= { batteryTableEntry 1 } + +batteryState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + degraded(4), + missing(5), + charging(6), + belowThreshold(7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current state of battery. + Possible values: + 1: The current state could not be determined. + 2: The battery is operating normally. + 3: The battery has failed and needs to be replaced. + 4: The battery temperature is high or charge level is depleting. + 5: The battery is missing or not detected. + 6: The battery is undergoing the re-charge phase. + 7: The battery voltage or charge level is below the threshold. + " + ::= { batteryTableEntry 4 } + +batteryComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the battery itself without the + propagation of any contained component status. + Possible values: + 1: Other + 2: Unknown + 3: OK + 4: Non-critical + 5: Critical + 6: Non-recoverable" + ::= { batteryTableEntry 6 } + +batteryPredictedCapacity OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + failed(2), + ready(3) + } + ACCESS read-only + STATUS obsolete + DESCRIPTION + "This entry is obsolete. Use the batteryComponentStatus or + batteryState instead. + " + ::= { batteryTableEntry 10 } + +batteryFQDD OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery's Fully Qualified Device Descriptor (FQDD) as + represented in Storage Management. + " + ::= { batteryTableEntry 20 } + +batteryDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The battery's friendly FQDD as represented in Storage Management." + ::= { batteryTableEntry 21 } + + + + +------------------------------------------------------------------------------- +-- Controller Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.<a>.<i1> +------------------------------------------------------------------------------- + +ControllerTableEntry ::=SEQUENCE { + controllerNumber INTEGER, + controllerName DisplayString, + controllerRebuildRate INTEGER, + controllerFWVersion DisplayString, + controllerCacheSizeInMB INTEGER, + controllerRollUpStatus ObjectStatusEnum, + controllerComponentStatus ObjectStatusEnum, + controllerDriverVersion DisplayString, + controllerPCISlot DisplayString, + controllerReconstructRate INTEGER, + controllerPatrolReadRate INTEGER, + controllerBGIRate INTEGER, + controllerCheckConsistencyRate INTEGER, + controllerPatrolReadMode INTEGER, + controllerPatrolReadState INTEGER, + controllerPersistentHotSpare BooleanType, + controllerSpinDownUnconfiguredDrives BooleanType, + controllerSpinDownHotSpareDrives BooleanType, + controllerSpinDownTimeInterval INTEGER, + controllerPreservedCache BooleanType, + controllerCheckConsistencyMode INTEGER, + controllerCopyBackMode INTEGER, + controllerSecurityStatus INTEGER, + controllerEncryptionKeyPresent BooleanType, + controllerEncryptionCapability INTEGER, + controllerLoadBalanceSetting INTEGER, + controllerMaxCapSpeed INTEGER, + controllerSASAddress DisplayString, + controllerFQDD FQDDString, + controllerDisplayName DisplayString, + controllerT10PICapability INTEGER, + controllerRAID10UnevenSpansSupported BooleanType, + controllerEnhancedAutoImportForeignConfigMode INTEGER, + controllerBootModeSupported BooleanType, + controllerBootMode INTEGER, + controllerHighAvailabilityMode INTEGER, + controllerPeerController FQDDString, + controllerEncryptionKeyIdentifier DisplayString +} + +controllerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ControllerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed RAID controllers. The number of entries + is related to number of RAID controllers discovered in the + system. The maximum number of entries is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 1 } + +controllerTableEntry OBJECT-TYPE + SYNTAX ControllerTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the table of RAID controllers. A row in this table + cannot be created or deleted by SNMP operations on columns of + the table." + INDEX { controllerNumber } + ::= { controllerTable 1 } + +controllerNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this controller entry." + ::= { controllerTableEntry 1 } + + +controllerName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's name as represented in Storage Management. + " + ::= { controllerTableEntry 2 } + +controllerRebuildRate OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The rebuild rate is the percentage of the controller's + resources dedicated to rebuilding a failed disk when a rebuild + is necessary. + " + ::= { controllerTableEntry 7 } + +controllerFWVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's current firmware version. + " + ::= { controllerTableEntry 8 } + +controllerCacheSizeInMB OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's current amount of cache memory in megabytes. + " + ::= { controllerTableEntry 9 } + +controllerRollUpStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Severity of the controller state. + This is the combined status of the controller and its components. + Possible values: + 1: Other. + 2: Unknown. + 3: OK + 4: Non-critical + 5: Critical. + 6: Non-recoverable. + " + ::= { controllerTableEntry 37 } + +controllerComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the controller itself without the + propagation of any contained component status. + Possible values: + 1: Other + 2: Unknown + 3: OK + 4: Non-critical + 5: Critical + 6: Non-recoverable" + ::= { controllerTableEntry 38 } + +controllerDriverVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Currently installed driver version for this controller on the host. + " + ::= { controllerTableEntry 41 } + +controllerPCISlot OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The PCI slot on the server where the controller is seated. This + data is not reported for embedded or integrated controllers, + " + ::= { controllerTableEntry 42 } + +controllerReconstructRate OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The reconstruct rate is the percentage of the controller's resources + dedicated to reconstructing a disk group after adding a physical disk + or changing the RAID level of a virtual disk residing on the disk + group. + " + ::= { controllerTableEntry 48 } + +controllerPatrolReadRate OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The patrol read rate is the percentage of the controller's + resources dedicated to perform a patrol read on disks participating + in a virtual disk or hot spares. + " + ::= { controllerTableEntry 49 } + +controllerBGIRate OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The background initialization (BGI) rate is the percentage of the + controller's resources dedicated to performing the background + initialization of a redundant virtual disk after it is created. + " + ::= { controllerTableEntry 50 } + +controllerCheckConsistencyRate OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The check consistency rate is the percentage of the + controller's resources dedicated to performing a check consistency + on a redundant virtual disk. + " + ::= { controllerTableEntry 51 } + +controllerPatrolReadMode OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + notSupported(2), + disabled(3), + auto(4), + manual(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Identifies the patrol read mode setting for the controller. + Possible values: + 1: Not one of the following or could not be determined. + 2: Not Supported on this controller. + 3: Disabled. + 4: Automatic. + 5: Manual. + " + ::= { controllerTableEntry 52 } + +controllerPatrolReadState OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + stopped(2), + active(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This property displays the current state of the patrol read process. + Possible values: + 1: Not one of the following or could not be determined. + 2: Patrol read is not running. + 3: Patrol read is running. + " + ::= { controllerTableEntry 53 } + +controllerPersistentHotSpare OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether hot spare drives would be restored on insertion + into the same slot. + " + ::= { controllerTableEntry 59 } + +controllerSpinDownUnconfiguredDrives OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether un-configured drives would be put in power + save mode by the controller. + " + ::= { controllerTableEntry 60 } + +controllerSpinDownHotSpareDrives OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether hot spare drives would be put in power + save mode by the controller. + " + ::= { controllerTableEntry 61 } + +controllerSpinDownTimeInterval OBJECT-TYPE + SYNTAX INTEGER (30..1440) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The duration in minutes after which, the unconfigured or hot + spare drives will be spun down to power save mode. + " + ::= { controllerTableEntry 62 } + +controllerPreservedCache OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether preserved cache or pinned cache is + present on the controller. + " + ::= { controllerTableEntry 69 } + +controllerCheckConsistencyMode OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + unsupported(2), + normal(3), + stopOnError(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current check consistency mode setting + for the controller. + Possible values: + 1: Not one of the following. + 2: Not supported on this controller. + 3: Normal check consistency operation. + 4: Check consistency operation will stop on encountering + an error. + " + ::= { controllerTableEntry 70 } + +controllerCopyBackMode OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + unsupported(2), + on(3), + onWithSmart(4), + off(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current copy back mode setting + for the controller. + Possible values: + 1: Not one of the following. + 2: Not supported on this controller. + 3: Disks assigned as spares could revert back to spare status. + 4: Data from physical disk participating in a + virtual disk could be automatically copied to the assigned + hot spare in case former has a predictive failure event. + 5: Copyback mode is disabled. + " + ::= { controllerTableEntry 71 } + +controllerSecurityStatus OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + none(2), + lkm(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's current security/encryption status.. + Possible values: + 1: The current status could not be determined. + 2: Controller is not operating in an encryption mode. + 3: Controller is operating in the Local Key Management + (LKM) encryption mode. + " + ::= { controllerTableEntry 72 } + +controllerEncryptionKeyPresent OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether encryption key is assigned for the controller. + " + ::= { controllerTableEntry 73 } + +controllerEncryptionCapability OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + none(2), + lkm(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of encryption supported by the controller. + Possible values: + 1: Not one of the following. + 2: No encryption supported, + 3: Local Key Management, + " + ::= { controllerTableEntry 74 } + +controllerLoadBalanceSetting OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + unsupported(2), + auto(3), + none(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The ability of the controller to automatically use both + controller ports (or connectors) connected to the same enclosure in + order to route I/O requests. + Possible values: + 1: Not one of the following. + 2: Not supported. + 3: Automatic load balancing is active. + 4: Load balancing is inactive. + " + ::= { controllerTableEntry 75 } + +controllerMaxCapSpeed OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + oneDotFiveGbps(2), + threeGbps(3), + sixGbps(4), + twelveGbps(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum speed of the controller.in + Gigbits per second (Gbps). + Possible values: + 1: The speed could not be determined. + 2. 1.5 Gbps + 3: 3.0 Gbps + 4: 6.0 Gbps + 5: 12.0 Gbps + " + ::= { controllerTableEntry 76 } + +controllerSASAddress OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SAS address of the controller. + " + ::= { controllerTableEntry 77 } + +controllerFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's Fully Qualified Device Descriptor (FQDD) as + represented in Storage Management. + " + ::= { controllerTableEntry 78 } + +controllerDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The controller's friendly FQDD as represented in Storage + Management." + ::= { controllerTableEntry 79 } + +controllerT10PICapability OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + capable(2), + notCapable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the controller supports the T10 PI (Protection + Information). These protection fields are known as DIF + (Data Integrity Fields). + Possible values: + 1: Not one of the following. + 2: Capable of supporting T10 PI. + 3: Not capable of supporting T10 PI. + " + ::= { controllerTableEntry 80 } + +controllerRAID10UnevenSpansSupported OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether uneven spans for RAID 10 virtual disk + is supported on the controller. + " + ::= { controllerTableEntry 81 } + +controllerEnhancedAutoImportForeignConfigMode OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + notSupported(2), + disabled(3), + enabled(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the status of enhanced auto-import of foreign + configuration property of the controller. + 1: Not one of the following. + 2: Not Supported. + 3: Disabled. + 4: Enabled. + " + ::= { controllerTableEntry 82 } + +controllerBootModeSupported OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether headless boot mode settings are supported + on the controller. + " + ::= { controllerTableEntry 83 } + +controllerBootMode OBJECT-TYPE + SYNTAX INTEGER + { + notApplicable(1), + user(2), + contOnError(3), + headlessContOnError(4), + headlessSafe(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the boot mode of the controller. + Possible values: + 1: Not applicable for this controller. + 2: User mode: User interaction required for all boot messages (not + applicable for uEFI environments). + 3: Continue Boot On Error. User interaction only required for + critical messages. + 4: Headless Mode Continue On Error. User interaction is not required. + Controller boot may halt on Error. + 5: Headless Safe Mode. Controller shall boot to safe mode on critical + errors. + " + ::= { controllerTableEntry 84 } + +controllerHighAvailabilityMode OBJECT-TYPE + SYNTAX INTEGER + { + none (1), + faultTolerantActivePassive (2), + faultTolerantActiveActive (3), + degraded (4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the fault-tolerant mode of the controller. + Possible values: + 1: None + 2: Fault Tolerant(Active/Passive) + 3: Fault Tolerant(Active/Active) + 4: Degraded + " + ::= { controllerTableEntry 85 } + +controllerPeerController OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The peer controller's Fully Qualified Device Descriptor (FQDD) as + represented in Storage Management. + " + ::= { controllerTableEntry 86 } + +controllerEncryptionKeyIdentifier OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Displays the encryption security key identifier of the controller, if the + controller is encryption enabled and a security key is configured for the + controller." + ::= { controllerTableEntry 87 } + + + + +------------------------------------------------------------------------------- +-- Physical Disk Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.<a>.<i1> +------------------------------------------------------------------------------- + +PhysicalDiskTableEntry ::=SEQUENCE { + physicalDiskNumber INTEGER, + physicalDiskName DisplayString, + physicalDiskManufacturer DisplayString, + physicalDiskState INTEGER, + physicalDiskProductID DisplayString, + physicalDiskSerialNo DisplayString, + physicalDiskRevision DisplayString, + physicalDiskCapacityInMB INTEGER, + physicalDiskUsedSpaceInMB INTEGER, + physicalDiskFreeSpaceInMB INTEGER, + physicalDiskBusType INTEGER, + physicalDiskSpareState INTEGER, + physicalDiskComponentStatus ObjectStatusEnum, + physicalDiskPartNumber DisplayString, + physicalDiskSASAddress DisplayString, + physicalDiskNegotiatedSpeed INTEGER, + physicalDiskCapableSpeed INTEGER, + physicalDiskSmartAlertIndication BooleanType, + physicalDiskManufactureDay DisplayString, + physicalDiskManufactureWeek DisplayString, + physicalDiskManufactureYear DisplayString, + physicalDiskMediaType INTEGER, + physicalDiskPowerState INTEGER, + physicalDiskRemainingRatedWriteEndurance INTEGER, + physicalDiskOperationalState INTEGER, + physicalDiskProgress INTEGER, + physicalDiskSecurityStatus INTEGER, + physicalDiskFormFactor INTEGER, + physicalDiskFQDD FQDDString, + physicalDiskDisplayName DisplayString, + physicalDiskT10PICapability INTEGER, + physicalDiskBlockSizeInBytes INTEGER, + physicalDiskProtocolVersion DisplayString, + physicalDiskPCIeNegotiatedLinkWidth INTEGER, + physicalDiskPCIeCapableLinkWidth INTEGER, + physicalDiskCurrentActiveController FQDDString, + physicalDiskFailoverController FQDDString, + physicalDiskForeignKeyIdentifier DisplayString + } + +physicalDiskTable OBJECT-TYPE + SYNTAX SEQUENCE OF PhysicalDiskTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed physical disks. The number of entries is + related to number of physical Disks discovered in the system. + The maximum number of entries is implementation dependent. + Note: The properties in this table may not be applicable to + all entries. + " + ::= { physicalDevices 4 } + +physicalDiskTableEntry OBJECT-TYPE + SYNTAX PhysicalDiskTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the physical Disk table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { physicalDiskNumber } + ::= { physicalDiskTable 1 } + +physicalDiskNumber OBJECT-TYPE + SYNTAX INTEGER (1..1000000000) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this physical disk entry. + " + ::= { physicalDiskTableEntry 1 } + +physicalDiskName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical disk's name as represented in Storage Management. + " + ::= { physicalDiskTableEntry 2 } + +physicalDiskManufacturer OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the physical disk's manufacturer. + " + ::= { physicalDiskTableEntry 3 } + +physicalDiskState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + online(3), + foreign(4), + offline(5), + blocked(6), + failed(7), + nonraid(8), + removed(9), + readonly(10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this physical disk. + Possible states: + 1: The current state could not be determined. + 2: The physical disk is available for use, but no RAID configuration + has been assigned. + 3: A RAID configuration has been assigned to the physical disk. + 4: The physical disk has been moved from another + controller and contains all or some portion of a virtual disk. + 5: The physical disk is not available to the RAID + controller. + 6: The physical disk is currently blocked by + controller. + 7: The physical disk is not operational. + 8: The physical disk is not a RAID capable disk + 9: The physical disk has been removed. + 10:The physical disk media has been placed in read only mode. + " + ::= { physicalDiskTableEntry 4 } + +physicalDiskProductID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The model number of the physical disk. + " + ::= { physicalDiskTableEntry 6 } + +physicalDiskSerialNo OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical disk's unique identification number + from the manufacturer. + " + ::= { physicalDiskTableEntry 7 } + +physicalDiskRevision OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware version of the physical disk. + " + ::= { physicalDiskTableEntry 8 } + +physicalDiskCapacityInMB OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the physical disk in megabytes. + " + ::= { physicalDiskTableEntry 11 } + +physicalDiskUsedSpaceInMB OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of used space in megabytes on the physical + disk. This is not applicable for NVMe devices. + " + ::= { physicalDiskTableEntry 17 } + +physicalDiskFreeSpaceInMB OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of free space in megabytes on the physical + disk. This is not applicable for NVMe devices. + " + ::= { physicalDiskTableEntry 19 } + +physicalDiskBusType OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + scsi(2), + sas(3), + sata(4), + fibre(5), + pcie(6) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The bus type of the physical disk. + Possible values: + 1: The bus type could not be determined. + 2: Small Computer System Interface (SCSI). + 3: Serial Attached SCSI (SAS). + 4: Serial Advanced Technology Attachment (SATA). + 5: Fibre channel. + 6: PCIe. + " + ::= { physicalDiskTableEntry 21 } + +physicalDiskSpareState OBJECT-TYPE + SYNTAX INTEGER + { + notASpare(1), + dedicatedHotSpare(2), + globalHotSpare(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the disk as a spare. + Possible values: + 1: Physical disk is not a spare. + 2: Physical disk is a dedicated hot spare. + 3: Physical disk is a global hot spare. + " + ::= { physicalDiskTableEntry 22 } + +physicalDiskComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the physical disk itself without the + propagation of any contained component status. + Possible values: + 1: Other + 2: Unknown + 3: OK + 4: Non-critical + 5: Critical + 6: Non-recoverable + " + ::= { physicalDiskTableEntry 24 } + +physicalDiskPartNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The part number of the disk. + " + ::= { physicalDiskTableEntry 27 } + +physicalDiskSASAddress OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SAS address of the physical disk. + " + ::= { physicalDiskTableEntry 28 } + +physicalDiskNegotiatedSpeed OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + oneDotFiveGbps(2), + threeGbps(3), + sixGbps(4), + twelveGbps(5), + fiveGTps(6), + eightGTps(7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The data transfer speed that the disk negotiated while spinning up + in Gigbits per second (Gbps). + Possible values: + 1: The speed could not be determined. + 2. 1.5 Gbps + 3: 3.0 Gbps + 4: 6.0 Gbps + 5: 12.0 Gbps + 6: 5 GT/s (applicable for NVMe devices). + 7: 8 GT/s (applicable for NVMe devices). + " + ::= { physicalDiskTableEntry 29 } + +physicalDiskCapableSpeed OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + oneDotFiveGbps(2), + threeGbps(3), + sixGbps(4), + twelveGbps(5), + fiveGTps(6), + eightGTps(7) + + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum data transfer speed supported by the disk + in Gigbits per second (Gbps). + Possible values: + 1: The speed could not be determined. + 2. 1.5 Gbps + 3: 3.0 Gbps + 4: 6.0 Gbps + 5: 12.0 Gbps + 6: 5 GT/s (applicable for NVMe devices). + 7: 8 GT/s (applicable for NVMe devices). + " + ::= { physicalDiskTableEntry 30 } + +physicalDiskSmartAlertIndication OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the physical disk has received a predictive + failure alert. + " + ::= { physicalDiskTableEntry 31 } + +physicalDiskManufactureDay OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The day of the week (1=Sunday thru 7=Saturday) + on which the physical disk was manufactured. + " + ::= { physicalDiskTableEntry 32 } + +physicalDiskManufactureWeek OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The week (1 thru 53) in which the physical disk + was manufactured. + " + ::= { physicalDiskTableEntry 33 } + +physicalDiskManufactureYear OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The four digit year in which the physical disk was manufactured. + " + ::= { physicalDiskTableEntry 34 } + +physicalDiskMediaType OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + hdd(2), + ssd(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The media type of the physical disk. + Possible Values: + 1: The media type could not be determined. + 2: Hard Disk Drive (HDD). + 3: Solid State Device (SSD). + " + ::= { physicalDiskTableEntry 35 } + +physicalDiskPowerState OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + spunUp(2), + spunDown(3), + transition(4), + on(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power state of the physical disk. + Possible Values: + 1: Not one of the following. + 2: The physical disk is in the spun up state. + 3: The physical disk is in the spun down state. + 4: The physical disk is changing from spun down state + to spun up state or vice versa. + 5: The Solid State Device (SSD) is powered on. + " + ::= { physicalDiskTableEntry 42 } + +physicalDiskRemainingRatedWriteEndurance OBJECT-TYPE + SYNTAX INTEGER (0..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This property is applicable to SSD media type only. This indicates + the wear-out percentage of the SSD. Typically it is a value between + 0 to 100. However, if the value is not available or not applicable + (in the case of HDD media type) the value will be 255. + " + ::= { physicalDiskTableEntry 49 } + +physicalDiskOperationalState OBJECT-TYPE + SYNTAX INTEGER + { + notApplicable(1), + rebuild(2), + clear(3), + copyback(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the physical disk when there are progressive + operations ongoing. + Possible values: + 1: There is no active operation running. + 2: Data from a redundant virtual disk is + currently being rebuilt onto the physical disk. + 3: Data on the disk is being erased. + 4: Data is being copied from a hot spare disk to + the physical disk or vice versa. + " + ::= { physicalDiskTableEntry 50 } + +physicalDiskProgress OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The progress percentage of the operation that is being + performed on the physical disk. This is applicable + only if there is a progressive operations ongoing + " + ::= { physicalDiskTableEntry 51 } + +physicalDiskSecurityStatus OBJECT-TYPE + SYNTAX INTEGER + { + supported(1), + notSupported(2), + secured(3), + locked(4), + foreign(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The security/encryption status of the physical disk. + Possible Values: + 1: The physical disk supports encryption. + 2: The physical disk does not support encryption + 3: The physical disk is encrypted. + 4: The physical disk is locked by a key. + 5: The physical disk is locked by a foreign key. + " + ::= { physicalDiskTableEntry 52 } + +physicalDiskFormFactor OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + oneDotEight(2), + twoDotFive(3), + threeDotFive(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The form factor of the physical disk. + Possible values: + 1: The form factor could not be determined. + 2: 1.8 inch. + 3: 2.5 inch. + 4: 3.5 inch. + " + ::= { physicalDiskTableEntry 53 } + +physicalDiskFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical disk's Fully Qualified Device Descriptor (FQDD) + as represented in Storage Management. + " + ::= { physicalDiskTableEntry 54 } + +physicalDiskDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical disk's friendly FQDD as represented in Storage + Management. + " + ::= { physicalDiskTableEntry 55 } + +physicalDiskT10PICapability OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + capable(2), + notCapable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the physical disk supports the T10 PI (Protection + Information). These protection fields are known as DIF + (Data Integrity Fields). + Possible values: + 1: Not one of the following. + 2: Capable of supporting T10 PI. + 3: Not capable of supporting T10 PI. + " + ::= { physicalDiskTableEntry 57 } + +physicalDiskBlockSizeInBytes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The block size (in bytes) of the physical disk. This is not + applicable for NVMe devices. + Possible values: + 1: 512. + 2: 4096 + " + ::= { physicalDiskTableEntry 58 } + +physicalDiskProtocolVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Applicable for NVMe devices only. The NVMe protocol version supported + by the device. + " + ::= { physicalDiskTableEntry 59 } + +physicalDiskPCIeNegotiatedLinkWidth OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + notApplicable(2), + byOne(3), + byTwp(4), + byFour(5), + byEight(6), + bySixteen(7), + byThirtyTwp(8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Applicable for NVMe devices only. The PCIe link width negotiated with the host + during device initialization. + " + ::= { physicalDiskTableEntry 60 } + +physicalDiskPCIeCapableLinkWidth OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + notApplicable(2), + byOne(3), + byTwp(4), + byFour(5), + byEight(6), + bySixteen(7), + byThirtyTwp(8) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Applicable for NVMe devices only. The PCIe link widths the device is capable of + supporting. + " + ::= { physicalDiskTableEntry 61 } + +physicalDiskCurrentActiveController OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Fully Qualified Device Descriptor (FQDD) of + the current active controller. + " + ::= { physicalDiskTableEntry 62 } + +physicalDiskFailoverController OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Fully Qualified Device Descriptor (FQDD) of + the failover controller. + " + ::= { physicalDiskTableEntry 63 } + +physicalDiskForeignKeyIdentifier OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Displays the encryption key identifier of the physical disk if it is in + locked or foreign state." + + ::= { physicalDiskTableEntry 64 } + + + +------------------------------------------------------------------------------- +-- Virtual Disk Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.<a>.<i1> +------------------------------------------------------------------------------- +VirtualDiskTableEntry ::=SEQUENCE { + virtualDiskNumber INTEGER, + virtualDiskName DisplayString, + virtualDiskState INTEGER, + virtualDiskSizeInMB INTEGER, + virtualDiskWritePolicy INTEGER, + virtualDiskReadPolicy INTEGER, + virtualDiskLayout INTEGER, + virtualDiskStripeSize INTEGER, + virtualDiskComponentStatus ObjectStatusEnum, + virtualDiskBadBlocksDetected BooleanType, + virtualDiskSecured BooleanType, + virtualDiskIsCacheCade BooleanType, + virtualDiskDiskCachePolicy INTEGER, + virtualDiskOperationalState INTEGER, + virtualDiskProgress INTEGER, + virtualDiskAvailableProtocols DisplayString, + virtualDiskMediaType DisplayString, + virtualDiskRemainingRedundancy INTEGER, + virtualDiskFQDD FQDDString, + virtualDiskDisplayName DisplayString, + virtualDiskT10PIStatus INTEGER, + virtualDiskBlockSizeInBytes INTEGER, + virtualDiskAdapter1AccessPolicy INTEGER, + virtualDiskAdapter2AccessPolicy INTEGER, + virtualDiskAdapter3AccessPolicy INTEGER, + virtualDiskAdapter4AccessPolicy INTEGER, + virtualDiskCurrentActiveController FQDDString, + virtualDiskFailoverController FQDDString +} + +virtualDiskTable OBJECT-TYPE + SYNTAX SEQUENCE OF VirtualDiskTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed virtual disks. The number of entries is related + to number of virtual disks discovered in the system. + The maximum number of entries is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { logicalDevices 1 } + +virtualDiskTableEntry OBJECT-TYPE + SYNTAX VirtualDiskTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the virtual disk table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { virtualDiskNumber } + ::= { virtualDiskTable 1 } + +virtualDiskNumber OBJECT-TYPE + SYNTAX INTEGER (1..100000000) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this virtual disk entry. + " + ::= { virtualDiskTableEntry 1 } + +virtualDiskName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The virtual disk's label as entered by the user. + " + ::= { virtualDiskTableEntry 2 } + +virtualDiskState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + online(2), + failed(3), + degraded(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this virtual disk + (which includes any member physical disks.) + Possible states: + 1: The current state could not be determined. + 2: The virtual disk is operating normally or optimally. + 3: The virtual disk has encountered a failure. The data on disk + is lost or is about to be lost. + 4: The virtual disk encounterd a failure with one or all of the + constituent redundant physical disks. The data on the virtual + disk might no longer be fault tolerant. + " + ::= { virtualDiskTableEntry 4 } + +virtualDiskSizeInMB OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The size of the virtual disk in megabytes. + " + ::= { virtualDiskTableEntry 6 } + +virtualDiskWritePolicy OBJECT-TYPE + SYNTAX INTEGER + { + writeThrough(1), + writeBack(2), + writeBackForce(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The write policy used by the controller for write operations on + this virtual disk. + Possible values: + 1: Write Through. + 2: Write Back. + 3: Force Write Back. + " + ::= { virtualDiskTableEntry 10 } + +virtualDiskReadPolicy OBJECT-TYPE + SYNTAX INTEGER + { + noReadAhead(1), + readAhead(2), + adaptiveReadAhead(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The read policy used by the controller for read operations on + this virtual disk. + Possible values: + 1: No Read Ahead. + 2: Read Ahead. + 3: Adaptive Read Ahead. + " + ::= { virtualDiskTableEntry 11 } + +virtualDiskLayout OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + r0(2), + r1(3), + r5(4), + r6(5), + r10(6), + r50(7), + r60(8), + concatRaid1(9), + concatRaid5(10) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The virtual disk's RAID type. + Possible values: + 1: Not one of the following + 2: RAID-0 + 3: RAID-1 + 4: RAID-5 + 5: RAID-6 + 6: RAID-10 + 7: RAID-50 + 8: RAID-60 + 9: Concatenated RAID 1 + 10: Concatenated RAID 5 + " + ::= { virtualDiskTableEntry 13 } + +virtualDiskStripeSize OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + default(2), + fiveHundredAndTwelvebytes(3), + oneKilobytes(4), + twoKilobytes(5), + fourKilobytes(6), + eightKilobytes(7), + sixteenKilobytes(8), + thirtyTwoKilobytes(9), + sixtyFourKilobytes(10), + oneTwentyEightKilobytes(11), + twoFiftySixKilobytes(12), + fiveOneTwoKilobytes(13), + oneMegabye(14), + twoMegabytes(15), + fourMegabytes(16), + eightMegabytes(17), + sixteenMegabytes(18) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The stripe size of this virtual disk. + Possible values: + 1: Not one of the following + 2: Default. + 3: 512 bytes + 4: 1 kB, + 5: 2 kB, + 6: 4 kB, + 7: 8 kB, + 8: 16 kB, + 9: 32 kB, + 10: 64 kB, + 11: 128 kB, + 12: 256 kB, + 13: 512 kB, + 14: 1 MB, + 15: 2 MB, + 16: 4 MB, + 17: 8 MB, + 18: 16 MB + " + ::= { virtualDiskTableEntry 14 } + +virtualDiskComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the virtual disk itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { virtualDiskTableEntry 20 } + +virtualDiskBadBlocksDetected OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the virtual disk has bad blocks. + " + ::= { virtualDiskTableEntry 23 } + +virtualDiskSecured OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the virtual disk is secured or not. + " + ::= { virtualDiskTableEntry 24 } + +virtualDiskIsCacheCade OBJECT-TYPE + SYNTAX BooleanType + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the virtual disk is being used as a secondary + cache by the controller. + " + ::= { virtualDiskTableEntry 25 } + +virtualDiskDiskCachePolicy OBJECT-TYPE + SYNTAX INTEGER + { + enabled(1), + disabled(2), + defullt(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The cache policy of the physical disks that are + part of this virtual disk + Possible values: + 1: Enabled. + 2: Disabled. + 3: Default. + " + ::= { virtualDiskTableEntry 26 } + +virtualDiskOperationalState OBJECT-TYPE + SYNTAX INTEGER + { + notApplicable(1), + reconstructing(2), + resynching(3), + initializing(4), + backgroundInit(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The state of the virtual disk when there are progressive + operations ongoing. + Possible values: + 1: There is no active operation running. + 2: The virtual disk configuration has changed. + The physical disks included in the virtual disk are being + modified to support the new configuration. + 3: A Consistency Check (CC) is being performed + on the virtual disk. + 4: The virtual disk is being initialized. + 5: BackGround Initialization (BGI) is being performed + on the virtual disk. + " + ::= { virtualDiskTableEntry 30 } + +virtualDiskProgress OBJECT-TYPE + SYNTAX INTEGER (0..100) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The progress percentage of the operation that is being + performed on the virtual disk. This is applicable + only if there is a progressive operations ongoing + " + ::= { virtualDiskTableEntry 31 } + +virtualDiskAvailableProtocols OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "List of protocols support by physical disks part of this virtual + disk. For e.g. SAS for Serial Attached SCSI or SATA for + Serial Advanced Technology Attachment. + " + ::= { virtualDiskTableEntry 32 } + +virtualDiskMediaType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "List of media types of the physical disks part of this virtual + disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. + " + ::= { virtualDiskTableEntry 33 } + +virtualDiskRemainingRedundancy OBJECT-TYPE + SYNTAX INTEGER (0..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of physical disks which can be lost before the + virtual disk loses its redundancy. + " + ::= { virtualDiskTableEntry 34 } + +virtualDiskFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The virtual disk's Fully Qualified Device Descriptor (FQDD) as + represented in Storage Management. + " + ::= { virtualDiskTableEntry 35 } + +virtualDiskDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The virtual disk's friendly FQDD as represented in Storage + Management. + " + ::= { virtualDiskTableEntry 36 } + +virtualDiskT10PIStatus OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + enabled(2), + disabled(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the virtual disk supports the T10 PI (Protection + Information). These protection fields are known as DIF + (Data Integrity Fields). + Possible values: + 1: Not one of the following. + 2: Enabled. + 3: Disabled. + " + ::= { virtualDiskTableEntry 37 } + +virtualDiskBlockSizeInBytes OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The block size (in bytes) of the physical disk part of the virtual disk. + Possible values: + 1: 512. + 2: 4096 + " + ::= { virtualDiskTableEntry 38 } + +virtualDiskAdapter1AccessPolicy OBJECT-TYPE + SYNTAX INTEGER + { + noAccess (1), + fullAccess (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the access policy of the virtual disk with the virtual + adapters. + Possible values: + 1: No Access. + 2: Full Access + " + ::= { virtualDiskTableEntry 39 } + +virtualDiskAdapter2AccessPolicy OBJECT-TYPE + SYNTAX INTEGER + { + noAccess (1), + fullAccess (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the access policy of the virtual disk with the virtual + adapters. + Possible values: + 1: No Access. + 2: Full Access + " + ::= { virtualDiskTableEntry 40 } + +virtualDiskAdapter3AccessPolicy OBJECT-TYPE + SYNTAX INTEGER + { + noAccess (1), + fullAccess (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the access policy of the virtual disk with the virtual + adapters. + Possible values: + 1: No Access. + 2: Full Access + " + ::= { virtualDiskTableEntry 41 } + +virtualDiskAdapter4AccessPolicy OBJECT-TYPE + SYNTAX INTEGER + { + noAccess (1), + fullAccess (2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the access policy of the virtual disk with the virtual + adapters. + Possible values: + 1: No Access. + 2: Full Access + " + ::= { virtualDiskTableEntry 42 } + +virtualDiskCurrentActiveController OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Fully Qualified Device Descriptor (FQDD) of + the current active controller. + " + ::= { virtualDiskTableEntry 43 } + +virtualDiskFailoverController OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the Fully Qualified Device Descriptor (FQDD) of + the failover controller. + " + ::= { virtualDiskTableEntry 44 } + + +------------------------------------------------------------------------------- +-- Enclosure Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.<a>.<i1> +------------------------------------------------------------------------------- + +EnclosureTableEntry ::=SEQUENCE { + enclosureNumber INTEGER, + enclosureName DisplayString, + enclosureState INTEGER, + enclosureServiceTag DisplayString, + enclosureAssetTag DisplayString, + enclosureConnectedPort DisplayString, + enclosureRollUpStatus ObjectStatusEnum, + enclosureComponentStatus ObjectStatusEnum, + enclosureFirmwareVersion DisplayString, + enclosureSASAddress DisplayString, + enclosureDriveCount INTEGER, + enclosureTotalSlots INTEGER, + enclosureFanCount DisplayString, + enclosurePSUCount DisplayString, + enclosureEMMCount DisplayString, + enclosureTempProbeCount DisplayString, + enclosureRedundantPath DisplayString, + enclosurePosition DisplayString, + enclosureBackplaneBayID DisplayString, + enclosureFQDD FQDDString, + enclosureDisplayName DisplayString, + enclosureType INTEGER +} + +enclosureTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosureTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed enclosures/backplanes. The number of entries is + related to number of internal backplane(s) discovered in the system + and external storage enclosure(s) attached to the system.. + The maximum number of entries is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 3 } + +enclosureTableEntry OBJECT-TYPE + SYNTAX EnclosureTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the enclosure table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { enclosureNumber } + ::= { enclosureTable 1 } + +enclosureNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this enclossre/backplane. + " + ::= { enclosureTableEntry 1 } + +enclosureName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure/backplane's name as represented in Storage Management. + " + ::= { enclosureTableEntry 2 } + +enclosureState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + missing(4), + degraded(5), + foreign(6), + offline(7), + online(8), + blocked(9) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this enclosure/backplane. + Possible states: + 1: The current state could not be determined. + 2: The enclosure is operating normally. + 3: The enclosure has encountered a hardware problem or is not + responding. + 4: The enclosure is no longer connected to the controller or + there exists a problem communicating to the enclosure. + 5: The enclosure is unstable. + 6: The enclosure is inactive due to being configured by another + controller. + 7: The enclosure is offline and inaccessible. + 8: The enclosure is online and accessible. + 9: The enclosure is currently blocked by another controller. + " + ::= { enclosureTableEntry 4 } + +enclosureServiceTag OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Enclosure identification used when consulting customer support. + " + ::= { enclosureTableEntry 8 } + +enclosureAssetTag OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The asset tag information for the enclosure." + ::= { enclosureTableEntry 9 } + +enclosureConnectedPort OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The port on the controller to which the + storage enclosure is connected. + " + ::= { enclosureTableEntry 19 } + +enclosureRollUpStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Severity of the enclosure/backplane state. + This is the combined status of the enclosure and its sub-components. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical. + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosureTableEntry 23 } + +enclosureComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the enclosure/backplane.itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosureTableEntry 24 } + +enclosureFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The firmware information for the enclosure/backplane. + " + ::= { enclosureTableEntry 26 } + +enclosureSASAddress OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SAS address of the enclosure/backplane. + " + ::= { enclosureTableEntry 30 } + +enclosureDriveCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of disks present in the enclosure/backplane. + " + ::= { enclosureTableEntry 31 } + +enclosureTotalSlots OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total physical drive slots in a storage enclosure + or server backplane. + " + ::= { enclosureTableEntry 32 } + +enclosureFanCount OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of fans present in the storage enclosure. + " + ::= { enclosureTableEntry 40 } + +enclosurePSUCount OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Power Supply Units (PSU) present + in the storage enclosure. + " + ::= { enclosureTableEntry 41 } + +enclosureEMMCount OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Enclosure Management Modules (EMM) + present in the storage enclosure. + " + ::= { enclosureTableEntry 42 } + +enclosureTempProbeCount OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of temperature sensing devices + present in the storage enclosure. + " + ::= { enclosureTableEntry 43 } + +enclosureRedundantPath OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates whether the controller has multiply paths to + reach the storage enclosure. + " + ::= { enclosureTableEntry 44 } + +enclosurePosition OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The possition of the storage enclosure within a daisy chain. + " + ::= { enclosureTableEntry 45 } + +enclosureBackplaneBayID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The unique bay ID of the backplane. + " + ::= { enclosureTableEntry 46 } + +enclosureFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) + as represented in Storage Management. + " + ::= { enclosureTableEntry 47 } + +enclosureDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure/backplane's friendly FQDD as represented in + Storage Management. + " + ::= { enclosureTableEntry 48 } + +enclosureType OBJECT-TYPE + SYNTAX INTEGER + { + other(1), + notApplicable(2), + sassata(3), + pcie(4), + universal(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The protocol supported by the backplane. + Possible states: + 1: Not one of the following or could not be determined. + 2: Not applicable (i.e. object is not a backplane). + 3: Supports SAS/SATA. + 4: Supports PCIe. + 5: Both SAS/SATA and PCIe. + " + ::= { enclosureTableEntry 49 } + + +------------------------------------------------------------------------------- +-- Enclosure Management Module Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.<a>.<i1> +------------------------------------------------------------------------------- + +EnclosureManagementModuleTableEntry ::=SEQUENCE { + enclosureManagementModuleNumber INTEGER, + enclosureManagementModuleName DisplayString, + enclosureManagementModuleState INTEGER, + enclosureManagementModulePartNumber DisplayString, + enclosureManagementModuleFWVersion DisplayString, + enclosureManagementModuleComponentStatus ObjectStatusEnum, + enclosureManagementModuleFQDD FQDDString, + enclosureManagementModuleDisplayName DisplayString +} + +enclosureManagementModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosureManagementModuleTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed Enclosure Management Modules (EMM) + in the external storage enclosure(s). The number of + entries is related to number of enclosure management modules + discovered in the enclosure(s). The maximum number of entries + is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 13 } + +enclosureManagementModuleTableEntry OBJECT-TYPE + SYNTAX EnclosureManagementModuleTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the enclosure management module table. A row in + this table cannot be created or deleted by SNMP operations + on columns of the table. + " + INDEX { enclosureManagementModuleNumber } + ::= { enclosureManagementModuleTable 1 } + +enclosureManagementModuleNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this enclosure management module. + " + ::= { enclosureManagementModuleTableEntry 1 } + +enclosureManagementModuleName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure management module's name as + represented in Storage Management. + " + ::= { enclosureManagementModuleTableEntry 2 } + +enclosureManagementModuleState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + missing(4), + degraded(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this enclosure management module. + Possible states: + 1: The current state could not be determined. + 2: The enclosure management module is operating normally. + 3: The enclosure management module has encountered a + hardware problem or is not responding. + 4: The enclosure management module is no longer connected + to the enclosure or there exists a problem communicating to it. + 5: The enclosure management module is unstable. + " + ::= { enclosureManagementModuleTableEntry 4 } + +enclosureManagementModulePartNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The part number of the enclosure management module. + " + ::= { enclosureManagementModuleTableEntry 6 } + +enclosureManagementModuleFWVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Firmware version of the enclosure management module. + " + ::= { enclosureManagementModuleTableEntry 8 } + +enclosureManagementModuleComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the enclosure management module.itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosureManagementModuleTableEntry 11 } + +enclosureManagementModuleFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure management module's Fully Qualified Device + Descriptor (FQDD) as represented in Storage Management. + " + ::= { enclosureManagementModuleTableEntry 15 } + +enclosureManagementModuleDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The enclosure management module's friendly FQDD as represented in + Storage Management. + " + ::= { enclosureManagementModuleTableEntry 16 } + + + +------------------------------------------------------------------------------- +-- Enclosure Fan Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.<a>.<i1> +------------------------------------------------------------------------------- + +EnclosureFanTableEntry ::=SEQUENCE { + enclosureFanNumber INTEGER, + enclosureFanName DisplayString, + enclosureFanState INTEGER, + enclosureFanSpeed INTEGER, + enclosureFanComponentStatus ObjectStatusEnum, + enclosureFanFQDD FQDDString, + enclosureFanDisplayName DisplayString +} + +enclosureFanTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosureFanTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed fans in the external storage enclosure(s). + The number of entries is related to number of fans discovered in + the enclosure(s). The maximum number of entries is implementation + dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 7 } + +enclosureFanTableEntry OBJECT-TYPE + SYNTAX EnclosureFanTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the fan table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { enclosureFanNumber } + ::= { enclosureFanTable 1 } + +enclosureFanNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this fan. + " + ::= { enclosureFanTableEntry 1 } + +enclosureFanName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fan's name as represented in Storage Management. + " + ::= { enclosureFanTableEntry 2 } + +enclosureFanState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + missing(4), + degraded(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this fan. + Possible states: + 1: The current state could not be determined. + 2: The fan is operating normally. + 3: The fan has encountered a hardware problem or is not + responding. + 4: The fan is no longer connected to the enclosure or + there exists a problem communicating to it. + 5: The fan is unstable. + " + ::= { enclosureFanTableEntry 4 } + +enclosureFanSpeed OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Indicates the current relative speed of the fan in RPMs. + " + ::= { enclosureFanTableEntry 11 } + +enclosureFanComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the fan itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosureFanTableEntry 15 } + +enclosureFanFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fan's Fully Qualified Device Descriptor (FQDD) + as represented in Storage Management. + " + ::= { enclosureFanTableEntry 20 } + +enclosureFanDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The fan's friendly FQDD as represented in + Storage Management. + " + ::= { enclosureFanTableEntry 21 } + + + + +------------------------------------------------------------------------------- +-- Enclosure Power Supply Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.<a>.<i1> +------------------------------------------------------------------------------- +EnclosurePowerSupplyTableEntry ::=SEQUENCE { + enclosurePowerSupplyNumber INTEGER, + enclosurePowerSupplyName DisplayString, + enclosurePowerSupplyState INTEGER, + enclosurePowerSupplyPartNumber DisplayString, + enclosurePowerSupplyComponentStatus ObjectStatusEnum, + enclosurePowerSupplyFQDD FQDDString, + enclosurePowerSupplyDisplayName DisplayString +} + +enclosurePowerSupplyTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosurePowerSupplyTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed Power Supply Units(PSU) in the external + storage enclosure(s). The number of entries is related to number + of power supply unit(s) discovered in the enclosure(s). The + maximum number of entries is implementation + dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 9 } + +enclosurePowerSupplyTableEntry OBJECT-TYPE + SYNTAX EnclosurePowerSupplyTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the power supply unit table. A row in this table cannot + be created or deleted by SNMP operations on columns of the table. + " + INDEX { enclosurePowerSupplyNumber } + ::= { enclosurePowerSupplyTable 1 } + +enclosurePowerSupplyNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this power supply unit. + " + ::= { enclosurePowerSupplyTableEntry 1 } + +enclosurePowerSupplyName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power supply unit's name as represented in + Storage Management. + " + ::= { enclosurePowerSupplyTableEntry 2 } + +enclosurePowerSupplyState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + missing(4), + degraded(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this power supply unit. + Possible states: + 1: The current state could not be determined. + 2: The power supply unit is operating normally. + 3: The power supply unit has encountered a hardware problem + or is not responding. + 4: The power supply unit is no longer connected to the enclosure + or there exists a problem communicating to it. + 5: The power supply unit is unstable. + " + ::= { enclosurePowerSupplyTableEntry 4 } + +enclosurePowerSupplyPartNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The part number of the power supply unit. + " + ::= { enclosurePowerSupplyTableEntry 7 } + +enclosurePowerSupplyComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the power supply unit itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosurePowerSupplyTableEntry 9 } + +enclosurePowerSupplyFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power supply unit's Fully Qualified Device Descriptor (FQDD) + as represented in Storage Management. + " + ::= { enclosurePowerSupplyTableEntry 15 } + +enclosurePowerSupplyDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The power supply unit's friendly FQDD as represented in + Storage Management. + " + ::= { enclosurePowerSupplyTableEntry 16 } + + +------------------------------------------------------------------------------- +-- Enclosure Temperature Probe Table +-- +-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.<a>.<i1> +------------------------------------------------------------------------------- +EnclosureTemperatureProbeTableEntry ::=SEQUENCE { + enclosureTemperatureProbeNumber INTEGER, + enclosureTemperatureProbeName DisplayString, + enclosureTemperatureProbeState INTEGER, + enclosureTemperatureProbeMinWarningValue INTEGER, + enclosureTemperatureProbeMinCriticalValue INTEGER, + enclosureTemperatureProbeMaxWarningValue INTEGER, + enclosureTemperatureProbeMaxCriticalValue INTEGER, + enclosureTemperatureProbeCurValue INTEGER, + enclosureTemperatureProbeComponentStatus ObjectStatusEnum, + enclosureTemperatureProbeFQDD FQDDString, + enclosureTemperatureProbeDisplayName DisplayString +} + +enclosureTemperatureProbeTable OBJECT-TYPE + SYNTAX SEQUENCE OF EnclosureTemperatureProbeTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table of managed temperature probes in the external storage + enclosure(s). The number of entries is related to number of + temperature probes discovered in the enclosure(s). The maximum + number of entries is implementation dependent. + Note: The properties in this table may not be applicable to all + entries. + " + ::= { physicalDevices 11 } + +enclosureTemperatureProbeTableEntry OBJECT-TYPE + SYNTAX EnclosureTemperatureProbeTableEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the temperature probe table. A row in this table cannot be + created or deleted by SNMP operations on columns of the table. + " + INDEX { enclosureTemperatureProbeNumber } + ::= { enclosureTemperatureProbeTable 1 } + +enclosureTemperatureProbeNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Instance number of this temperature probe. + " + ::= { enclosureTemperatureProbeTableEntry 1 } + +enclosureTemperatureProbeName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature probe's name as represented in + Storage Management. + " + ::= { enclosureTemperatureProbeTableEntry 2 } + +enclosureTemperatureProbeState OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + ready(2), + failed(3), + missing(4), + degraded(5), + overWarning(6), + underWarning(7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The current state of this temperature probe. + Possible states: + 1: The current state could not be determined. + 2: The temperature probe is operating normally. + 3: The temperature probe has encountered a hardware problem + or is not responding. + 4: The temperature probe is no longer connected to the enclosure + or there exists a problem communicating to it. + 5: The temperature probe is unstable. + 6: The temperature probe is Over Warning Temperature. + 7: The temperature probe is Under Warning Temperature. + " + ::= { enclosureTemperatureProbeTableEntry 4 } + +enclosureTemperatureProbeMinWarningValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature that will force the probe into + a warning state. + " + ::= { enclosureTemperatureProbeTableEntry 7 } + +enclosureTemperatureProbeMinCriticalValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minimum temperature that will force the probe into + a error state. + " + ::= { enclosureTemperatureProbeTableEntry 8 } + +enclosureTemperatureProbeMaxWarningValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum temperature that will force the probe into + a warning state. + " + ::= { enclosureTemperatureProbeTableEntry 9 } + +enclosureTemperatureProbeMaxCriticalValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum temperature that will force the probe into + a warning state. + " + ::= { enclosureTemperatureProbeTableEntry 10 } + +enclosureTemperatureProbeCurValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum temperature that will force the probe into + a warning state. + " + ::= { enclosureTemperatureProbeTableEntry 11 } + +enclosureTemperatureProbeComponentStatus OBJECT-TYPE + SYNTAX ObjectStatusEnum + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The status of the enclosure management module.itself without the + propagation of any contained component status. + Possible values: + 1: Other. + 2: Unknown. + 3: OK. + 4: Non-critical . + 5: Critical. + 6: Non-recoverable. + " + ::= { enclosureTemperatureProbeTableEntry 13 } + +enclosureTemperatureProbeFQDD OBJECT-TYPE + SYNTAX FQDDString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature probe's Fully Qualified Device Descriptor (FQDD) + as represented in Storage Management. + " + ::= { enclosureTemperatureProbeTableEntry 15 } + +enclosureTemperatureProbeDisplayName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature probe's friendly FQDD as represented + in Storage Management. + " + ::= { enclosureTemperatureProbeTableEntry 16 } + + + ------------------------------------------------------------------------------- + -- group: Chassis Alerts 1 + ------------------------------------------------------------------------------- + + drsCASubSystem OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert" + ::= { drsChassisAlertVariables 1 } + + drsCASSCurrStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting + Sub-System" + ::= { drsChassisAlertVariables 2 } + + drsCASSPrevStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting + Sub-System" + ::= { drsChassisAlertVariables 3 } + + drsCASSChangeTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of + the Alerting Sub-System" + ::= { drsChassisAlertVariables 4 } + + drsCAMessage OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert" + ::= { drsChassisAlertVariables 5 } + + alertCMCTestTrap TRAP-TYPE + ENTERPRISE drsOutofBandGroup + DESCRIPTION "The CMC has generated a test trap" + --#TYPE "CMC Test Trap" + --#SUMMARY "CMC Test Trap" + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 2000 + + alertCMCNormalTrap TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsProductChassisName, + drsProductChassisLocation, + drsGlobalCurrStatus, + drsCASubSystem, + drsCASSCurrStatus, + drsCASSPrevStatus, + drsCASSChangeTime, + drsCAMessage } + DESCRIPTION "The CMC reported a return-to-normal or informational event." + --#TYPE "CMC Return-to-Normal / Informational Trap" + --#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s" + --#ARGUMENTS {0,1,7} + --#SEVERITY NORMAL + --#CATEGORY Error Events + ::= 2002 + + alertCMCWarningTrap TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsProductChassisName, + drsProductChassisLocation, + drsGlobalCurrStatus, + drsCASubSystem, + drsCASSCurrStatus, + drsCASSPrevStatus, + drsCASSChangeTime, + drsCAMessage } + DESCRIPTION "The CMC reported a warning event." + --#TYPE "CMC Warning Trap" + --#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s" + --#ARGUMENTS {0,1,7} + --#SEVERITY WARNING + --#CATEGORY Error Events + ::= 2003 + + alertCMCCriticalTrap TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsProductChassisName, + drsProductChassisLocation, + drsGlobalCurrStatus, + drsCASubSystem, + drsCASSCurrStatus, + drsCASSPrevStatus, + drsCASSChangeTime, + drsCAMessage } + DESCRIPTION "The CMC reported a critical event." + --#TYPE "CMC Critical Trap" + --#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s" + --#ARGUMENTS {0,1,7} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 2004 + + alertCMCNonRecoverableTrap TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsProductChassisName, + drsProductChassisLocation, + drsGlobalCurrStatus, + drsCASubSystem, + drsCASSCurrStatus, + drsCASSPrevStatus, + drsCASSChangeTime, + drsCAMessage } + DESCRIPTION "The CMC reported a catastrophic event." + --#TYPE "CMC Non-Recoverable Trap" + --#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s" + --#ARGUMENTS {0,1,7} + --#SEVERITY NON-RECOVERABLE + --#CATEGORY Error Events + ::= 2005 + + ------------------------------------------------------------------------------- + -- group: Chassis Alerts 2 + ------------------------------------------------------------------------------- + + drsCA2MessageID OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..8)) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Message ID of the alert." + ::= { drsChassisAlert2Variables 1 } + + drsCA2Message OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Message describing the alert." + ::= { drsChassisAlert2Variables 2 } + + drsCA2MessageArgs OBJECT-TYPE + SYNTAX DellString + ACCESS read-only + STATUS mandatory + DESCRIPTION "Concatenated set of strings representing any message arguments + that were used to construct the alert message. Each message + argument string is enclosed in double quotes, and there is a + comma after the ending double quote of each message argument + string, except the last one. Any double quotes found within a + message argument string were preprocessed and changed to single + quotes." + ::= { drsChassisAlert2Variables 3 } + + drsCA2AlertStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION "Status of the alert." + ::= { drsChassisAlert2Variables 4 } + + drsCA2FQDD OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..512)) + ACCESS read-only + STATUS mandatory + DESCRIPTION "Fully qualified device descriptor of device causing the alert." + ::= { drsChassisAlert2Variables 5 } + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Amperage Probe Traps + -- + -- Category: System/1 + -- Subcategory: AMP/16 + ------------------------------------------------------------------------------ + + alert2AmperageProbeNormal TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Current sensor reading is within range." + --#TYPE "System: Amperage Normal" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2179 + + alert2AmperageProbeWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Current sensor has detected a warning value." + --#TYPE "System: Amperage Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2178 + + alert2AmperageProbeFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Current sensor has detected a failure value." + --#TYPE "System: Amperage Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2177 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Battery Traps + -- + -- Category: System/1 + -- Subcategory: BAT/22 + ------------------------------------------------------------------------------ + + alert2BatteryNormal TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Battery state has returned to normal; + or battery presence had been detected." + --#TYPE "System: Battery Normal" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2227 + + alert2BatteryWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Battery is low." + --#TYPE "System: Battery Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2226 + + alert2BatteryFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Battery has failed or battery is absent." + --#TYPE "System: Battery Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2225 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Cable Traps + -- + -- Category: System/1 + -- Subcategory: CBL/43 + ------------------------------------------------------------------------------ + + alert2CableFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Cable failure." + --#TYPE "System: Cable Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2393 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: CMC Traps + -- + -- Category: System/1 + -- Subcategory: CMC/62 + ------------------------------------------------------------------------------ + + alert2CMCWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Chassis Management Controller detected a warning." + --#TYPE "System: CMC Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2546 + + alert2CMCFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Chassis Management Controller detected an error." + --#TYPE "System: CMC Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2545 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Fan Traps + -- + -- Category: System/1 + -- Subcategory: FAN/13 + ------------------------------------------------------------------------------ + + alert2FanInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Fan information." + --#TYPE "System: Fan Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2155 + + alert2FanWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Fan warning." + --#TYPE "System: Fan Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2154 + + alert2FanFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Fan failure." + --#TYPE "System: Fan Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2153 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Hardware Configuration Traps + -- + -- Category: System/1 + -- Subcategory: HWC/35 + ------------------------------------------------------------------------------ + + alert2HardwareConfigurationInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Hardware configuration information." + --#TYPE "System: Hardware Configuration Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2331 + + alert2HardwareConfigurationWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Hardware configuration warning." + --#TYPE "System: Hardware Configuration Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2330 + + alert2HardwareConfigurationFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Hardware configuration failure or critical event." + --#TYPE "System: Hardware Configuration Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2329 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: IO Virtualization Traps + -- + -- Category: System/1 + -- Subcategory: IOV/63 + ------------------------------------------------------------------------------ + + alert2IOVirtualizationInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization information." + --#TYPE "System: IO Virtualization Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2555 + + alert2IOVirtualizationWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization warning." + --#TYPE "System: IO Virtualization Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2554 + + alert2IOVirtualizationFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization failure or critical event." + --#TYPE "System: IO Virtualization Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2553 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Link Status Traps + -- + -- Category: System/1 + -- Subcategory: LNK/25 + ------------------------------------------------------------------------------ + + alert2LinkStatusInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Link status information." + --#TYPE "System: Link Status Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2251 + + alert2LinkStatusWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Link status warning." + --#TYPE "System: Link Status Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2250 + + alert2LinkStatusFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Link status failure or critical event." + --#TYPE "System: Link Status Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2249 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: PCI Device Traps + -- + -- Category: System/1 + -- Subcategory: PCI/46 + ------------------------------------------------------------------------------ + + alert2PCIDeviceInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PCI device information." + --#TYPE "System: PCI Device Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2419 + + alert2PCIDeviceWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PCI device warning." + --#TYPE "System: PCI Device Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2418 + + alert2PCIDeviceFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PCI device failure or critical event." + --#TYPE "System: PCI Device Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2417 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Power Supply Traps + -- + -- Category: System/1 + -- Subcategory: PSU/17 + ------------------------------------------------------------------------------ + + alert2PowerSupplyNormal TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power supply has returned to normal." + --#TYPE "System: Power Supply Normal" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2187 + + alert2PowerSupplyWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power supply has detected a warning." + --#TYPE "System: Power Supply Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2186 + + alert2PowerSupplyFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power supply has detected a failure." + --#TYPE "System: Power Supply Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2185 + + alert2PowerSupplyRedundancyPolicyChanged TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PSU redundancy policy changed." + --#TYPE "System: Power Supply Redundancy policy changed" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 8331 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Power Supply Absent Traps + -- + -- Category: System/1 + -- Subcategory: PSUA/52 + ------------------------------------------------------------------------------ + + alert2PowerSupplyAbsent TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power supply is absent." + --#TYPE "System: Power Supply Absent" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2465 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Power Usage Traps + -- + -- Category: System/1 + -- Subcategory: PWR/28 + ------------------------------------------------------------------------------ + + alert2PowerUsageInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage information." + --#TYPE "System: Power Usage Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2275 + + alert2PowerUsageWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage warning." + --#TYPE "System: Power Usage Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2274 + + alert2PowerUsageFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage failure." + --#TYPE "System: Power Usage Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2273 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Redundancy Traps + -- + -- Category: System/1 + -- Subcategory: RDU/53 + ------------------------------------------------------------------------------ + + alert2RedundancyInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Redundancy information." + --#TYPE "System: Redundancy Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2475 + + alert2RedundancyDegraded TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Redundancy is degraded." + --#TYPE "System: Redundancy Degraded" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2474 + + alert2RedundancyLost TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Redundancy is lost." + --#TYPE "System: Redundancy Lost" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2473 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Security Event Traps + -- + -- Category: System/1 + -- Subcategory: SEC/42 + ------------------------------------------------------------------------------ + + alert2SecurityInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Security information." + --#TYPE "System: Security Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2387 + + alert2SecurityWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Security warning." + --#TYPE "System: Security Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2386 + + alert2SecurityFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Security failure or critical event." + --#TYPE "System: Security Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2385 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: System Event Log Traps + -- + -- Category: System/1 + -- Subcategory: SEL/41 + ------------------------------------------------------------------------------ + + alert2SystemEventLogInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "System Event Log information." + --#TYPE "System: System Event Log Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2379 + + alert2SystemEventLogWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "System Event Log warning." + --#TYPE "System: System Event Log Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2378 + + alert2SystemEventLogFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "System Event Log failure or critical event." + --#TYPE "System: System Event Log Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2377 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Software Configuration Traps + -- + -- Category: System/1 + -- Subcategory: SWC/36 + ------------------------------------------------------------------------------ + + alert2SoftwareConfigurationInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software configuration information." + --#TYPE "System: Software Configuration Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2339 + + alert2SoftwareConfigurationWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software configuration warning." + --#TYPE "System: Software Configuration Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2338 + + alert2SoftwareConfigurationFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software configuration failure." + --#TYPE "System: Software Configuration Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2337 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Temperature Probe Traps + -- + -- Category: System/1 + -- Subcategory: TMP/14 + ------------------------------------------------------------------------------ + + alert2TemperatureProbeNormal TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Temperature sensor value is within range." + --#TYPE "System: Temperature Normal" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2163 + + alert2TemperatureProbeWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Temperature sensor has detected a warning value." + --#TYPE "System: Temperature Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2162 + + alert2TemperatureProbeFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Temperature sensor has detected a failure value." + --#TYPE "System: Temperature Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2161 + + alert2IOMTemperatureExceeded TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "I/O Module <iom slot name> temperature exceeded operating range." + --#TYPE "System: Temperature Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8305 + + alert2Unable2ReadTemperatureSensors TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system." + --#TYPE "System: Temperature Failure" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8306 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: System: Voltage Probe Traps + -- + -- Category: System/1 + -- Subcategory: VLT/15 + ------------------------------------------------------------------------------ + + alert2VoltageProbeNormal TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Voltage sensor reading is within range." + --#TYPE "System: Voltage Normal" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 2171 + + alert2VoltageProbeWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Voltage sensor has detected a warning value." + --#TYPE "System: Voltage Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2170 + + alert2VoltageProbeFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Voltage sensor has detected a failure value." + --#TYPE "System: Voltage Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 2169 + + ------------------------------------------------------------------------------- + -- Chassis Alerts 2: Storage: Battery Traps + -- + -- Category: Storage/2 + -- Subcategory: BAT/22 + ------------------------------------------------------------------------------- + + alert2StorageBatteryInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Battery information." + --#TYPE "Storage: Battery Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4275 + + alert2StorageBatteryWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Battery warning." + --#TYPE "Storage: Battery Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4274 + + alert2StorageBatteryFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Battery failure." + --#TYPE "Storage: Battery Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4273 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Controller Traps + -- + -- Category: Storage/2 + -- Subcategory: CTL/29 + ------------------------------------------------------------------------------ + + alert2StorageControllerInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Controller information." + --#TYPE "Storage: Controller Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4331 + + alert2StorageControllerWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Controller warning." + --#TYPE "Storage: Controller Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4330 + + alert2StorageControllerFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Controller failure." + --#TYPE "Storage: Controller Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4329 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Enclosure Traps + -- + -- Category: Storage/2 + -- Subcategory: ENC/30 + ------------------------------------------------------------------------------ + + alert2StorageEnclosureInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Enclosure information." + --#TYPE "Storage: Enclosure Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4339 + + alert2StorageEnclosureWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Enclosure warning." + --#TYPE "Storage: Enclosure Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4338 + + alert2StorageEnclosureFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Enclosure failure." + --#TYPE "Storage: Enclosure Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4337 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Fan Traps + -- + -- Category: Storage/2 + -- Subcategory: FAN/13 + ------------------------------------------------------------------------------ + + alert2StorageFanInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Fan information." + --#TYPE "Storage: Fan Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4203 + + alert2StorageFanWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Fan warning." + --#TYPE "Storage: Fan Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4202 + + alert2StorageFanFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Fan failure." + --#TYPE "Storage: Fan Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4201 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Physical Disk Traps + -- + -- Category: Storage/2 + -- Subcategory: PDR/31 + ------------------------------------------------------------------------------ + + alert2StoragePhysicalDiskInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Physical disk information." + --#TYPE "Storage: Physical Disk Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4347 + + alert2StoragePhysicalDiskWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Physical disk warning." + --#TYPE "Storage: Physical Disk Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4346 + + alert2StoragePhysicalDiskFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Physical disk failure." + --#TYPE "Storage: Physical Disk Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4345 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Power Supply Traps + -- + -- Category: Storage/2 + -- Subcategory: PSU/17 + ------------------------------------------------------------------------------ + + alert2StoragePowerSupplyInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Power supply information." + --#TYPE "Storage: Power Supply Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4235 + + alert2StoragePowerSupplyWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Power supply warning." + --#TYPE "Storage: Power Supply Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4234 + + alert2StoragePowerSupplyFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Power supply failure." + --#TYPE "Storage: Power Supply Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4233 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Security Event Traps + -- + -- Category: Storage/2 + -- Subcategory: SEC/42 + ------------------------------------------------------------------------------ + + alert2StorageSecurityInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Security information." + --#TYPE "Storage: Security Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4435 + + alert2StorageSecurityWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Security warning." + --#TYPE "Storage: Security Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4434 + + alert2StorageSecurityFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Security failure or critical event." + --#TYPE "Storage: Security Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4433 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Storage Management Status Traps + -- + -- Category: Storage/2 + -- Subcategory: STOR/10 + ------------------------------------------------------------------------------ + + alert2StorageManagementInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Management information. + There is no global status change associated with this trap." + --#TYPE "Storage: Storage Management Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4179 + + alert2StorageManagementWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Management has detected a device independent warning + condition. There is no global status change associated with this + trap." + --#TYPE "Storage: Storage Management Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4178 + + alert2StorageManagementFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Management has detected a device independent error condition. + There is no global status change associated with this trap." + --#TYPE "Storage: Storage Management Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4177 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Temperature Probe Traps + -- + -- Category: Storage/2 + -- Subcategory: TMP/14 + ------------------------------------------------------------------------------ + + alert2StorageTemperatureProbeInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Temperature probe information." + --#TYPE "Storage: Temperature Probe Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4211 + + alert2StorageTemperatureProbeWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Temperature probe warning." + --#TYPE "Storage: Temperature Probe Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4210 + + alert2StorageTemperatureProbeFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Temperature probe failure." + --#TYPE "Storage: Temperature Probe Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4209 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Storage: Virtual Disk Traps + -- + -- Category: Storage/2 + -- Subcategory: VDR/32 + ------------------------------------------------------------------------------ + + alert2StorageVirtualDiskInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Virtual disk information." + --#TYPE "Storage: Virtual Disk Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 4355 + + alert2StorageVirtualDiskWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Virtual disk warning." + --#TYPE "Storage: Virtual Disk Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 4354 + + alert2StorageVirtualDiskFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Storage Virtual disk failure." + --#TYPE "Storage: Virtual Disk Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE FAILED + --#STATUS MANDATORY + ::= 4353 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Updates: Software Change Traps + -- + -- Category: Updates/3 + -- Subcategory: SWU/21 + ------------------------------------------------------------------------------ + + alert2SoftwareChangeUpdateWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software change update warning." + --#TYPE "Updates: Software Change Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 6314 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: CMC Traps + -- + -- Category: Audit/4 + -- Subcategory: CMC/62 + ------------------------------------------------------------------------------ + + alert2CMCAuditInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Chassis Management Controller audit information." + --#TYPE "Audit: CMC Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 8691 + + alert2CMCAuditWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Chassis Management Controller audit warning." + --#TYPE "Audit: CMC Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8690 + + alert2CMCAuditFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Chassis Management Controller audit failure or critical event." + --#TYPE "Audit: CMC Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8689 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: IO Virtualization Traps + -- + -- Category: Audit/4 + -- Subcategory: IOV/63 + ------------------------------------------------------------------------------ + + alert2IOVirtualizationAuditWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization audit warning." + --#TYPE "Audit: IO Virtualization Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8698 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: License Traps + -- + -- Category: Audit/4 + -- Subcategory: LIC/40 + ------------------------------------------------------------------------------ + + alert2LicenseInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "License information." + --#TYPE "Audit: License Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 8515 + + alert2LicenseWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "License warning." + --#TYPE "Audit: License Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8514 + + alert2LicenseFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "License failure." + --#TYPE "Audit: License Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8513 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: PCI Device Traps + -- + -- Category: Audit/4 + -- Subcategory: PCI/46 + ------------------------------------------------------------------------------ + + alert2PCIDeviceAuditWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PCI device audit warning." + --#TYPE "Audit: PCI Device Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8562 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: Power Supply Traps + -- + -- Category: Audit/4 + -- Subcategory: PSU/17 + ------------------------------------------------------------------------------ + + alert2PowerSupplyAuditWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power Supply audit warning." + --#TYPE "Audit: Power Supply Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8330 + + alert2PowerSupplyAuditFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power Supply audit failure or critical event." + --#TYPE "Audit: Power Supply Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8329 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: Power Usage Traps + -- + -- Category: Audit/4 + -- Subcategory: PWR/28 + ------------------------------------------------------------------------------ + + alert2PowerUsageAuditInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage audit information." + --#TYPE "Audit: Power Usage Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 8419 + + alert2PowerUsageAuditWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage audit warning." + --#TYPE "Audit: Power Usage Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8418 + + alert2PowerUsageAuditFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Power usage audit failure or critical event." + --#TYPE "Audit: Power Usage Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8417 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Audit: Software Change Traps + -- + -- Category: Audit/4 + -- Subcategory: SWU/21 + ------------------------------------------------------------------------------ + + alert2SoftwareChangeAuditFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software change audit failure or critical event." + --#TYPE "Audit: Software Change Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 8361 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Configuration: IO Virtualization Traps + -- + -- Category: Configuration/5 + -- Subcategory: IOV/63 + ------------------------------------------------------------------------------ + + alert2IOVConfigurationInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization configuration information." + --#TYPE "Configuration: IO Virtualization Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 10747 + + alert2IOVConfigurationWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "IO Virtualization configuration warning." + --#TYPE "Configuration: IO Virtualization Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 10746 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Configuration: PCI Device Traps + -- + -- Category: Configuration/5 + -- Subcategory: PCI/46 + ------------------------------------------------------------------------------ + + alert2PCIDeviceConfigurationInformation TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "PCI device configuration information." + --#TYPE "Configuration: PCI Device Information" + --#SEVERITY INFORMATIONAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 10611 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Configuration: Software Configuration Traps + -- + -- Category: Configuration/5 + -- Subcategory: SWC/36 + ------------------------------------------------------------------------------ + + alert2SWCConfigurationWarning TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software configuration warning." + --#TYPE "Configuration: Software Configuration Warning" + --#SEVERITY MINOR + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Status Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 10530 + + alert2SWCConfigurationFailure TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Software configuration failure." + --#TYPE "Configuration: Software Configuration Failure" + --#SEVERITY CRITICAL + --#SUMMARY "Message ID: %s, Message: %s," + --#SUMMARY "Device Status: %d, Device FQDD: %s," + --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," + --#SUMMARY "Chassis Location: %s, Global Status: %d" + --#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8} + --#CATEGORY "Error Events" + --#STATE DEGRADED + --#STATUS MANDATORY + ::= 10529 + + ------------------------------------------------------------------------------ + -- Chassis Alerts 2: Configuration: Test Traps + -- + -- Category: Configuration/5 + -- Subcategory: TST/19 + ------------------------------------------------------------------------------ + + alert2CMCTestTrap TRAP-TYPE + ENTERPRISE drsCMCAlert2Group + VARIABLES { drsCA2MessageID, + drsCA2Message, + drsCA2MessageArgs, + drsCA2AlertStatus, + drsCA2FQDD, + drsProductChassisName, + drsProductChassisLocation, + drsChassisServiceTag, + drsGlobalCurrStatus } + DESCRIPTION + "Test trap generated by CMC in response to a user request." + --#TYPE "Configuration: CMC Test Trap" + --#SEVERITY INFORMATIONAL + --#SUMMARY "%s" + --#ARGUMENTS {1} + --#CATEGORY "Status Events" + --#STATE OPERATIONAL + --#STATUS MANDATORY + ::= 10395 + + ------------------------------------------------------------------------------- + -- group: Legacy Alerts + ------------------------------------------------------------------------------- + + drsAlertSystem OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..255)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0001 Name of the system generating the alert." + --DEFAULT get-function-async get_%n_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 1 } + + drsAlertTableIndexOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0002 0.0" + --DEFAULT get-function-async get_OID_null_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 2 } + + drsAlertMessage OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..1024)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0003 Message describing the alert." + --DEFAULT get-function-async get_string_null_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 3 } + + drsAlertCurrentStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0004 Current status of object causing the alert." + --DEFAULT get-function-async get_dellstatus_unknow_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 4 } + + drsAlertPreviousStatus OBJECT-TYPE + SYNTAX DellStatus + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0005 Previous status of object causing the alert." + --DEFAULT get-function-async get_dellstatus_unknow_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 5 } + + drsAlertData OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..1024)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5000.0010.0006 Alert data." + --DEFAULT get-function-async get_string_null_async + --DEFAULT next-function-async std_next_async + ::= { drsAlertVariables 6 } + + alertDrscTestTrapEvent TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC generated a test trap event in response to a user request." + --#TYPE "Dell RAC Test TRAP Event" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Status Events + ::= 1001 + + alertDrscAuthError TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC Authentication Failures during a time period have Exceeded a Threshold." + --#TYPE "Dell RAC Authentication Error" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MINOR + --#CATEGORY Error Events + ::= 1002 + + alertDrscLostESM TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC cannot communicate with the baseboard management controller (ESM)." + --#TYPE "Dell RAC Lost Communication with ESM" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MINOR + --#CATEGORY Error Events + ::= 1003 + + alertDrscFoundESM TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC is communicating normally with the baseboard management controller (ESM)." + --#TYPE "Dell RAC Communication with ESM is OK" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 1004 + + alertDrscPowerOff TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected a System power state change to powered-off." + --#TYPE "Dell RAC Detected System Powered-Off" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 1005 + + alertDrscPowerOn TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected a system power state change to powered-on." + --#TYPE "Dell RAC Detected System Powered-On" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 1006 + + alertDrscWatchdogExpired TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected that the system watchdog has expired indicating a system hang." + --#TYPE "Dell RAC Detected Watchdog Expired" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 1007 + + alertDrscBattLow TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes." + --#TYPE "Dell RAC Battery Charge Low" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MINOR + --#CATEGORY Error Events + ::= 1008 + + alertDrscTempNormal TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC Temperature probe has retured to a normal value." + --#TYPE "Dell RAC Temperature Normal" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 1009 + + alertDrscTempWarning TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC Temperature probe has detected a Warning value." + --#TYPE "Dell RAC Temperature Warning" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MINOR + --#CATEGORY Error Events + ::= 1010 + + alertDrscTempCritical TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC Temperature probe has detected a failure (or critical) value." + --#TYPE "Dell RAC Temperature Failure" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 1011 + + alertDrscVoltNormal TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC voltage has returned to a normal value." + --#TYPE "Dell RAC Voltage Normal" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 1012 + + alertDrscVoltWarning TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC voltage probe has detected a warning value." + --#TYPE "Dell RAC Battery Warning" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MINOR + --#CATEGORY Error Events + ::= 1013 + + alertDrscVoltCritical TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC voltage probe has detected a failure (or critical) value." + --#TYPE "Dell RAC Voltage Failure" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 1014 + + alertDrscSELWarning TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected a new event in the System Event Log with Severity: Warning." + --#TYPE "Dell RAC System Event Log Warning" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MAJOR + --#CATEGORY Error Events + ::= 1015 + + alertDrscSELCritical TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected a new event in the System Event Log with Severity: Critical." + --#TYPE "Dell RAC System Event Log Critical" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY CRITICAL + --#CATEGORY Error Events + ::= 1016 + + alertDrscSEL80percentFull TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected that the System Event Log is 80% full." + --#TYPE "Dell System Event Log 80% Full Warning" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MAJOR + --#CATEGORY Status Events + ::= 1017 + + alertDrscSEL90percentFull TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected that the System Event Log is 90% full." + --#TYPE " Dell System Event Log 90% Full Warning " + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MAJOR + --#CATEGORY Status Events + ::= 1018 + + alertDrscSEL100percentFull TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected that the System Event Log is 100% full." + --#TYPE " Dell System Event Log 100% Full Warning " + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY MAJOR + --#CATEGORY Status Events + ::= 1019 + + alertDrscSELNormal TRAP-TYPE + ENTERPRISE drsOutofBandGroup + VARIABLES { drsAlertSystem, + drsAlertTableIndexOID, + drsAlertMessage, + drsAlertCurrentStatus, + drsAlertPreviousStatus, + drsAlertData } + DESCRIPTION + "The RAC has detected a new event in the System Event Log with Severity: Normal." + --#TYPE "Dell RAC System Event Log Normal" + --#SUMMARY "%s" + --#ARGUMENTS {2} + --#SEVERITY INFORMATIONAL + --#CATEGORY Error Events + ::= 1020 +END + |