-rw-r--r--MIBS/dell/BROADCOM-POWER-ETHERNET-MIB351
1 files changed, 351 insertions, 0 deletions
diff --git a/MIBS/dell/BROADCOM-POWER-ETHERNET-MIB b/MIBS/dell/BROADCOM-POWER-ETHERNET-MIB
new file mode 100644
index 0000000..830e923
--- /dev/null
+++ b/MIBS/dell/BROADCOM-POWER-ETHERNET-MIB
@@ -0,0 +1,351 @@
+BROADCOM-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
+
+-- Copyright Broadcom Corporation (2003-2007) All rights reserved.
+
+-- This SNMP Management Information Specification
+-- embodies Broadcom Corporation's confidential and proprietary
+-- intellectual property. Broadcom Corporation retains all title
+-- and ownership in the Specification including any revisions.
+
+-- This Specification is supplied "AS IS", Broadcom Corporation
+-- makes no warranty, either expressed or implied,
+-- as to the use, operation, condition, or performance of the
+-- Specification.
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI
+ TruthValue FROM SNMPv2-TC
+ fastPath FROM BROADCOM-REF-MIB
+ pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
+
+
+ fastPathpowerEthernetMIB MODULE-IDENTITY
+ LAST-UPDATED "200708191200Z" -- 17 Aug 2007 12:00:00 GMT
+ ORGANIZATION "Broadcom Corporation"
+ CONTACT-INFO
+ " Customer Support
+ Postal: Broadcom Corporation
+ 100 Perimeter Park Dr., Suite H
+ Morrisville, NC 27560
+ Tel: +1 919 865 2700"
+
+ DESCRIPTION
+ "This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
+ Interfaces and Hub MIB Working Group for managing Power Source
+ Equipment (PSE). The objects in this MIB are intended to provide
+ additional objects for reporting information available to the hardware
+ on this platform which are not represented in the draft MIB."
+
+ -- Revision history.
+ REVISION
+ "200708191200Z" -- 17 Aug 2007 12:00:00 GMT
+ DESCRIPTION
+ "PoE support for BCM59101 added."
+ REVISION
+ "200705230000Z" -- 23 May 2007 12:00:00 GMT
+ DESCRIPTION
+ "Broadcom branding related changes."
+ REVISION
+ "200311101200Z" -- 10 Nov 2003 12:00:00 GMT
+ DESCRIPTION
+ "Initial revision."
+ ::= { fastPath 15 }
+
+ agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
+
+ agentPethPsePortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentPethPsePortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of per-port information and configuration objects relating
+ to the power status of each port."
+ ::= { agentPethObjects 1 }
+
+ agentPethPsePortEntry OBJECT-TYPE
+ SYNTAX AgentPethPsePortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing additional power information
+ and control parameters for the specified port."
+ AUGMENTS { pethPsePortEntry }
+ ::= { agentPethPsePortTable 1 }
+
+ AgentPethPsePortEntry ::= SEQUENCE {
+ agentPethPowerLimit
+ Gauge32,
+ agentPethOutputPower
+ Gauge32,
+ agentPethOutputCurrent
+ Gauge32,
+ agentPethOutputVolts
+ Gauge32,
+ agentPethTemperature
+ Gauge32,
+ agentPethPowerLimitType
+ INTEGER,
+ agentPethHighPowerEnable
+ TruthValue,
+ agentPethPowerDetectionType
+ INTEGER,
+ agentPethFaultStatus
+ INTEGER,
+ agentPethPortReset
+ INTEGER
+ }
+
+ agentPethPowerLimit OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Milliwatts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configured maximum power this port can provide to an
+ attached device measured in Milliwatts."
+ ::= { agentPethPsePortEntry 1 }
+
+ agentPethOutputPower OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Milliwatts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power this port is supplying to an attached device measured
+ in Milliwatts."
+ ::= { agentPethPsePortEntry 2 }
+
+ agentPethOutputCurrent OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Milliamps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current this port is supplying to an attached device measured
+ in Milliamps."
+ ::= { agentPethPsePortEntry 3 }
+
+ agentPethOutputVolts OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage this port is supplying to an attached device measured
+ in Volts."
+ ::= { agentPethPsePortEntry 4 }
+
+ agentPethTemperature OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "DEGREES"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature measured at this port of the PoE Controller. It is
+ measured in degree celcius."
+ ::= { agentPethPsePortEntry 5 }
+
+ agentPethPowerLimitType OBJECT-TYPE
+ SYNTAX INTEGER {
+ dot3af(1),
+ user(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the maximum power that a port can deliver
+ A value of dot3af(1) means that the port power limit is as per
+ the dot3af class of the PD attached.
+ A value of user(2) means that the port power limit is equal to the value
+ specified by agentPethPowerLimit"
+ REFERENCE
+ "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
+
+ ::= { agentPethPsePortEntry 6 }
+
+ agentPethHighPowerEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "true (1) The PSE port can deliver power up to 32Watts.
+ false(2) The PSE port can deliver power up to 18Watts"
+ REFERENCE
+ "Broadcom 5910X programmers guide"
+
+ ::= { agentPethPsePortEntry 7 }
+
+ agentPethPowerDetectionType OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ legacy(1),
+ fourPtdot3afonly(2),
+ fourPtdot3afandlegacy(3),
+ twoPtdot3afonly(4),
+ twoPtdot3afandlegacy(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes PD detection mechanism performed by the PSE port.
+ A value of none(0) means no detection is done.
+ A value of legacy(1) means only legacy capacitive detection scheme is
+ used.
+ A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme
+ is used.
+ A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme
+ is used and when that fails to detect a connected PD, legacity capacitive detection
+ is used.
+ A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme
+ is used.
+ A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme
+ is used and when that fails to detect a connected PD, legacity capacitive detection
+ is used.
+ The value 'none' can not be forcibly set by the administrator."
+ REFERENCE
+ "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
+
+ ::= { agentPethPsePortEntry 8 }
+
+ agentPethFaultStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ mpsAbsent(1),
+ short(2),
+ overload(3),
+ powerDenied(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Describes the error description when the pse port is in fault status.
+ A value of none(0) specifies that the pse port is not in any error state.
+ A value of mpsAbsent(1) specifies that the pse port has detected and absence
+ of main power supply.
+ A value of short(2) specifies that the pse port has detected a short circuit
+ condition.
+ A value of overload(3) specifies that the pd connected to the pse port had tried
+ to draw more power than permissible by the hardware.
+ A value of powerDenied(4) specifies that the pse port has been denied power
+ because of shortage of power or due to administrative action."
+ REFERENCE
+ "Broadcom 5910X programmers guide, IEEE Std 802.3af"
+
+ ::= { agentPethPsePortEntry 9 }
+
+ agentPethPortReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ reset(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A value of reset(1) is used to move the pse port dot3af state to idle. A
+ read on this object will always return the value none(0). The value none(0)
+ can not be forcibly set by the administrtor."
+ REFERENCE
+ "Broadcom 5910X programmers guide, IEEE Std 802.3af"
+
+ ::= { agentPethPsePortEntry 10 }
+
+
+-- Main objects
+ agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
+
+ agentPethMainPseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentPethMainPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of objects that display and control attributes
+ of the main power source in a PSE device. Ethernet
+ switches are one example of boxes that would support
+ these objects.
+ Values of all read-write objects in this table are
+ persistent at restart/reboot."
+ ::= { agentPethMainPseObjects 1 }
+
+ agentPethMainPseEntry OBJECT-TYPE
+ SYNTAX AgentPethMainPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of objects that display and control the Main
+ power of a PSE. "
+ AUGMENTS { pethMainPseEntry }
+ ::= { agentPethMainPseTable 1 }
+
+ AgentPethMainPseEntry ::= SEQUENCE {
+ agentPethMainPseLegacy
+ TruthValue
+ }
+
+ agentPethMainPseLegacy OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable Legacy device detection. The
+ value true(1) means legacy devices are detected; the
+ value false(2) means legacy devices are not detected."
+ ::= { agentPethMainPseEntry 1 }
+
+ agentPethPseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentPethPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of per-unit information and configuration objects relating
+ to the power configurtion for the entire pse unit."
+ ::= { agentPethObjects 3 }
+
+ agentPethPseEntry OBJECT-TYPE
+ SYNTAX AgentPethPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing additional power information
+ and control parameters for the specified pse unit."
+ AUGMENTS { pethMainPseEntry }
+ ::= { agentPethPseTable 1 }
+
+ AgentPethPseEntry ::= SEQUENCE {
+ agentPethPsePowerManagementMode
+ INTEGER,
+ agentPethPseAutoResetEnable
+ TruthValue
+ }
+
+ agentPethPsePowerManagementMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ dynamic(1),
+ static(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the power management algorithm used by the pse
+ to deliver power to the requesting PDsthat a pds.
+ A value of dot3af(1) means that the port power limit is as per
+ the dot3af class of the PD attached.
+ A value of user(2) means that the port power limit is equal to the value
+ specified by agentPethPowerLimit"
+ REFERENCE
+ "Broadcom 5910X programmers guide"
+
+ ::= { agentPethPseEntry 1 }
+
+ agentPethPseAutoResetEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "true (1) The PSE port is reset with out administrator intervention whenver a
+ fault condition occurs.
+ false(2) Administrator has to reset the pse port whenver a fault condition
+ is detected."
+
+ ::= { agentPethPseEntry 2 }
+END