diff --git a/MIBS/cyberpower/CPS-MIB b/MIBS/cyberpower/CPS-MIB
new file mode 100644
index 0000000..41d49a3
--- /dev/null
+++ b/MIBS/cyberpower/CPS-MIB
@@ -0,0 +1,11470 @@
+--/********************* (c) 2010-2019 CyberPower System ***************************/
+--
+-- PROJECT: SNMP MIB FILE CONSTRUCTED
+--
+-- Version : 2.9
+--
+-- File Name: CPSMIB2019.mib
+--
+-- CREATION DATE : 10/23/2019
+--
+-- AUTHOR : Kevin
+--
+--//////////////////////////////////////////////////////////////////////////////
+--
+-- DESCRIPTION : CPS Management Information Base(MIB)
+--
+--//////////////////////////////////////////////////////////////////////////////
+--
+--
+--/****************************************************************************/
+-- CPSMIB { iso org(3) dod(6) internet(1) private(4)
+-- enterprises(1) cps(3808) }
+
+CPS-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI
+ DisplayString FROM RFC1213-MIB
+ OBJECT-TYPE FROM RFC-1212
+ TRAP-TYPE FROM RFC-1215;
+
+
+cps OBJECT IDENTIFIER ::= { enterprises 3808 }
+
+products OBJECT IDENTIFIER ::= { cps 1 }
+cpsmgmt OBJECT IDENTIFIER ::= { cps 2 }
+
+hardware OBJECT IDENTIFIER ::= { products 1 }
+
+
+mconfig OBJECT IDENTIFIER ::= { cpsmgmt 1 }
+mtrapinfo OBJECT IDENTIFIER ::= { cpsmgmt 2 }
+mcontrol OBJECT IDENTIFIER ::= { cpsmgmt 3 }
+
+ups OBJECT IDENTIFIER ::= { hardware 1 }
+eswitch OBJECT IDENTIFIER ::= { hardware 2 }
+ePDU OBJECT IDENTIFIER ::= { hardware 3 }
+environmentSensor OBJECT IDENTIFIER ::= { hardware 4 }
+ats OBJECT IDENTIFIER ::= { hardware 5 }
+ePDU2 OBJECT IDENTIFIER ::= { hardware 6 }
+battmgr OBJECT IDENTIFIER ::= { hardware 7 }
+
+mconfigClock OBJECT IDENTIFIER ::= { mconfig 5 }
+
+
+upsIdent OBJECT IDENTIFIER ::= { ups 1 }
+upsBattery OBJECT IDENTIFIER ::= { ups 2 }
+upsInput OBJECT IDENTIFIER ::= { ups 3 }
+upsOutput OBJECT IDENTIFIER ::= { ups 4 }
+upsConfig OBJECT IDENTIFIER ::= { ups 5 }
+upsControl OBJECT IDENTIFIER ::= { ups 6 }
+upsTest OBJECT IDENTIFIER ::= { ups 7 }
+upsOutlet OBJECT IDENTIFIER ::= { ups 8 }
+upsPhase OBJECT IDENTIFIER ::= { ups 9 }
+upsSystem OBJECT IDENTIFIER ::= { ups 10 }
+
+upsBaseIdent OBJECT IDENTIFIER ::= { upsIdent 1 }
+upsAdvanceIdent OBJECT IDENTIFIER ::= { upsIdent 2 }
+
+upsBaseBattery OBJECT IDENTIFIER ::= { upsBattery 1 }
+upsAdvanceBattery OBJECT IDENTIFIER ::= { upsBattery 2 }
+
+upsBaseInput OBJECT IDENTIFIER ::= { upsInput 1 }
+upsAdvanceInput OBJECT IDENTIFIER ::= { upsInput 2 }
+
+upsBaseOutput OBJECT IDENTIFIER ::= { upsOutput 1 }
+upsAdvanceOutput OBJECT IDENTIFIER ::= { upsOutput 2 }
+
+upsBaseConfig OBJECT IDENTIFIER ::= { upsConfig 1 }
+upsAdvanceConfig OBJECT IDENTIFIER ::= { upsConfig 2 }
+
+upsBaseControl OBJECT IDENTIFIER ::= { upsControl 1 }
+upsAdvanceControl OBJECT IDENTIFIER ::= { upsControl 2 }
+
+upsBaseTest OBJECT IDENTIFIER ::= { upsTest 1 }
+upsAdvanceTest OBJECT IDENTIFIER ::= { upsTest 2 }
+
+upsBankOutletControl OBJECT IDENTIFIER ::= { upsOutlet 1 }
+
+upsPhaseInput OBJECT IDENTIFIER ::= { upsPhase 1 }
+upsPhaseOutput OBJECT IDENTIFIER ::= { upsPhase 2 }
+upsPhaseBypass OBJECT IDENTIFIER ::= { upsPhase 3 }
+
+eSwitchIdent OBJECT IDENTIFIER ::= { eswitch 1 }
+eSwitchBase OBJECT IDENTIFIER ::= { eswitch 2 }
+
+
+ePDUIdent OBJECT IDENTIFIER ::= { ePDU 1 }
+ePDULoad OBJECT IDENTIFIER ::= { ePDU 2 }
+ePDUOutlet OBJECT IDENTIFIER ::= { ePDU 3 }
+ePDUPowerSupply OBJECT IDENTIFIER ::= { ePDU 4 }
+ePDUStatus OBJECT IDENTIFIER ::= { ePDU 5 }
+
+ePDULoadDevice OBJECT IDENTIFIER ::= { ePDULoad 1 }
+ePDULoadPhaseConfig OBJECT IDENTIFIER ::= { ePDULoad 2 }
+ePDULoadStatus OBJECT IDENTIFIER ::= { ePDULoad 3 }
+ePDULoadBankConfig OBJECT IDENTIFIER ::= { ePDULoad 4 }
+
+ePDUOutletDevice OBJECT IDENTIFIER ::= { ePDUOutlet 1 }
+ePDUOutletPhase OBJECT IDENTIFIER ::= { ePDUOutlet 2 }
+ePDUOutletControl OBJECT IDENTIFIER ::= { ePDUOutlet 3 }
+ePDUOutletConfig OBJECT IDENTIFIER ::= { ePDUOutlet 4 }
+ePDUOutletStatus OBJECT IDENTIFIER ::= { ePDUOutlet 5 }
+ePDUOutletBank OBJECT IDENTIFIER ::= { ePDUOutlet 6 }
+
+ePDUPowerSupplyDevice OBJECT IDENTIFIER ::= { ePDUPowerSupply 1 }
+
+envirIdent OBJECT IDENTIFIER ::= { environmentSensor 1 }
+envirTemp OBJECT IDENTIFIER ::= { environmentSensor 2 }
+envirHumid OBJECT IDENTIFIER ::= { environmentSensor 3 }
+envirContact OBJECT IDENTIFIER ::= { environmentSensor 4 }
+
+atsIdent OBJECT IDENTIFIER ::= { ats 1 }
+atsStatus OBJECT IDENTIFIER ::= { ats 2 }
+atsConfig OBJECT IDENTIFIER ::= { ats 3 }
+atsControl OBJECT IDENTIFIER ::= { ats 4 }
+atsLoad OBJECT IDENTIFIER ::= { ats 5 }
+atsOutlet OBJECT IDENTIFIER ::= { ats 6 }
+
+atsStatusDevice OBJECT IDENTIFIER ::= { atsStatus 1 }
+atsStatusInput OBJECT IDENTIFIER ::= { atsStatus 2 }
+
+atsLoadDevice OBJECT IDENTIFIER ::= { atsLoad 1 }
+atsLoadStatus OBJECT IDENTIFIER ::= { atsLoad 2 }
+atsLoadConfig OBJECT IDENTIFIER ::= { atsLoad 3 }
+
+atsOutletDevice OBJECT IDENTIFIER ::= { atsOutlet 1 }
+
+-- ePDU2 1 as Role OID.
+ePDU2Ident OBJECT IDENTIFIER ::= { ePDU2 2 }
+ePDU2Device OBJECT IDENTIFIER ::= { ePDU2 3 }
+ePDU2Phase OBJECT IDENTIFIER ::= { ePDU2 4 }
+ePDU2Bank OBJECT IDENTIFIER ::= { ePDU2 5 }
+ePDU2Outlet OBJECT IDENTIFIER ::= { ePDU2 6 }
+
+ePDU2OutletSwitched OBJECT IDENTIFIER ::= { ePDU2Outlet 1 }
+ePDU2OutletMetered OBJECT IDENTIFIER ::= { ePDU2Outlet 2 }
+
+ePDU2Sensor OBJECT IDENTIFIER ::= { ePDU2 7 }
+ePDU2Group OBJECT IDENTIFIER ::= { ePDU2 8 }
+
+bmIdent OBJECT IDENTIFIER ::= { battmgr 1 }
+bmProperty OBJECT IDENTIFIER ::= { battmgr 2 }
+bmConfig OBJECT IDENTIFIER ::= { battmgr 3 }
+bmControl OBJECT IDENTIFIER ::= { battmgr 4 }
+bmProbes OBJECT IDENTIFIER ::= { battmgr 5 }
+bmFuncRes OBJECT IDENTIFIER ::= { battmgr 6 }
+bmFuncEqual OBJECT IDENTIFIER ::= { battmgr 7 }
+
+bmFuncResMeasure OBJECT IDENTIFIER ::= { bmFuncRes 1 }
+
+-- object types
+-- the cpsmgmt group
+-- the mconfig group
+mconfigNumTrapAccepters OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of receivers to send traps to."
+ ::= { mconfig 1 }
+
+mconfigTrapAccepterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MconfigTrapAccepterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of receivers to send traps to. The numbers of
+ entries are given by the value of mconfigNumTrapAccepters."
+ ::= { mconfig 2 }
+
+mconfigTrapAccepterEntry OBJECT-TYPE
+ SYNTAX MconfigTrapAccepterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The receivers to send traps to."
+ INDEX { trapIndex }
+ ::= { mconfigTrapAccepterTable 1 }
+
+MconfigTrapAccepterEntry ::=
+ SEQUENCE {
+ trapIndex
+ INTEGER,
+ accepterAddr
+ IpAddress,
+ communityString
+ DisplayString,
+ severityDegree
+ INTEGER,
+ accepterActive
+ INTEGER
+ }
+
+trapIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The trap receiver entry index."
+ ::= { mconfigTrapAccepterEntry 1 }
+
+accepterAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The trap receiver IP address."
+ ::= { mconfigTrapAccepterEntry 2 }
+
+communityString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The trap receiver community name."
+ ::= { mconfigTrapAccepterEntry 3 }
+
+severityDegree OBJECT-TYPE
+ SYNTAX INTEGER {
+ information(1),
+ warning(2),
+ severe(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The trap receiver severity level. Traps are marked in severity level
+ as informational(1), warning(2), severe(3). Only send the traps of
+ equal or greater severity than this value to the receiver."
+ ::= { mconfigTrapAccepterEntry 4 }
+
+accepterActive OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A receiver will accept traps if yes, and none if no."
+ ::= { mconfigTrapAccepterEntry 5 }
+
+mconfigDHCPEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The system will automatically obtain its IP from a DHCP server if yes,
+ and none if no."
+ ::= { mconfig 3 }
+
+mconfigMyAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system IP address."
+ ::= { mconfig 4 }
+
+
+mconfigClockDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The current date in the mm/dd/yyyy format. Example: 01/01/2000."
+ ::= { mconfigClock 1 }
+
+mconfigClockTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The current time in the hh:mm:ss 24H format."
+ ::= { mconfigClock 2 }
+
+
+
+-- The mtrapinfo group
+-- These OIDs allows CPS traps to be sent with additional arguments
+-- which may not be defined in the CPS MIB.
+mtrapinfoInteger OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an integer argument for providing detail
+ information. Not being defined in the MIB, only reply 0."
+ ::= { mtrapinfo 1 }
+
+mtrapinfoIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an IP address argument for providing detail
+ information. Not being defined in the MIB, only reply 0.0.0.0."
+ ::= { mtrapinfo 2 }
+
+mtrapinfoString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an octet string argument for providing detail
+ information. Not being defined in the MIB, only reply a NULL string."
+ ::= { mtrapinfo 3 }
+
+mtrapinfoGauge OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an Gauge argument for providing detail
+ information. Not being defined in the MIB, only reply 0."
+ ::= { mtrapinfo 4 }
+
+mtrapinfoTimeTicks OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an TimeTicks argument for providing detail
+ information. Not being defined in the MIB, only reply 0."
+ ::= { mtrapinfo 5 }
+
+mtrapinfoBmEventId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Allow CPS traps with an integer argument for providing detail
+ information about Battery Manager specific event identifier.
+ Not being defined in the MIB, only reply 0.
+
+ Known Specific Event ID: Battery Manager
+ 0 - not used
+ 1 - Alarm: The battery manager system fault.
+ 2 - Info: Device configuration changed.
+ 3 - Alarm: Probe configuration mismatched.
+ 4 - Info: Probe configuration matched.
+ 5 - Alarm: Communication with battery manager has been lost.
+ 6 - Info: Communication with battery manager has been restored.
+ 7 - Alarm: Communication with LCD has been lost.
+ 8 - Info: Communication with LCD has been restored.
+ 9 - Warning: Enter battery equalization active mode.
+ 10- Warning: Leave battery equalization active mode.
+ 11- Alarm: Battery equalizing has failed.
+ 12- Info: Battery equalizing succeed.
+
+ Known Specific Event ID: Battery Probes
+ 101 - Alarm: Low battery voltage.
+ 102 - Alarm: High battery voltage.
+ 103 - Info: Battery voltage event has cleared.
+ 104 - Alarm: Low battery temperature.
+ 105 - Alarm: High battery temperature.
+ 106 - Info: Battery temperature event has cleared.
+ 107 - Alarm: Critical low battery resistance.
+ 108 - Alarm: Critical high battery resistance.
+ 109 - Warning: Low battery resistance.
+ 110 - Warning: high battery resistance.
+ 111 - Info: Battery resistance event has cleared.
+ 112 - Alarm: Battery resistance health has crossed alarm threshold.
+ 113 - Warning: Battery resistance health has crossed warning threshold.
+ 114 - Info: Battery resistance health has returned to Normal. "
+ ::= { mtrapinfo 6 }
+
+-- The mcontrol group
+mcontrolRestart OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ restartCurrentSystem (2),
+ restartCurrentAgent (3),
+ restartCurrentSystemAndAgent (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to restartCurrentSystem (2) will restart the current system.
+ Setting this OID to restartCurrentAgent (3) will restart the current agent.
+ Setting this OID to restartCurrentSystemAnd Agent (4) will restart the current
+ the current system and agent."
+
+ ::= { mcontrol 1 }
+
+mcontrolReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ resetCurrentSystem (2),
+ resetCurrentAgent (3),
+ resetCurrentSystemAndAgent (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to resetCurrentSystem (2) will reset the current system.
+ Setting this OID to resetCurrentAgent (3) will reset the current agent.
+ Setting this OID to resetCurrentSystemAndAgenta (4) will reset the current
+ system and the current agent."
+
+ ::= { mcontrol 2 }
+
+-- the ups group
+-- the upsIdent group
+-- the upsBaseIdent
+upsBaseIdentModel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS model name."
+ ::= { upsBaseIdent 1 }
+
+upsBaseIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS identified name could be set by the administrator."
+ ::= { upsBaseIdent 2 }
+
+
+-- the upsAdvanceIdent group
+upsAdvanceIdentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS firmware revision."
+ ::= { upsAdvanceIdent 1 }
+
+upsAdvanceIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS manufacture date in mm/dd/yy format."
+ ::= { upsAdvanceIdent 2 }
+
+upsAdvanceIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS serial number in the internal microprocessor."
+ ::= { upsAdvanceIdent 3 }
+
+upsAdvanceIdentAgentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SNMP agent firmware revision."
+ ::= { upsAdvanceIdent 4 }
+
+upsAdvanceIdentLCDFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The revision number of the UPS LCD firmware."
+ ::= { upsAdvanceIdent 5 }
+
+upsAdvanceIdentPowerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Volt-Amp rating of the UPS."
+ ::= { upsAdvanceIdent 6 }
+
+upsAdvanceIdentLoadPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power rating(Watts) of the UPS."
+ ::= { upsAdvanceIdent 7 }
+
+upsAdvanceIdentCurrentRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The output current rating of the UPS. Measured in tenths of Amps."
+ ::= { upsAdvanceIdent 8 }
+
+upsAdvanceIdentAgentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the serial number of the Agent."
+ ::= { upsAdvanceIdent 9 }
+
+-- the upsBattery group
+-- the upsBaseBattery group
+upsBaseBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ batteryNormal(2),
+ batteryLow(3),
+ batteryNotPresent(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery status. A batteryLow(3) value means the
+ battery will be exhausted soon under the current load.
+ The amount of low battery run time can be configured by the
+ upsAdvanceConfigLowBatteryRunTime."
+ ::= { upsBaseBattery 1 }
+
+upsBaseBatteryTimeOnBattery OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS wasted battery time since the UPS has transfered to
+ backup mode."
+ ::= { upsBaseBattery 2 }
+
+upsBaseBatteryLastReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS batteries last replaced date in mm/dd/yyyy format.
+ This value is originally set when manufactured. If batteries
+ replaced, administrator should reset this value."
+ ::= { upsBaseBattery 3 }
+
+upsBaseBatteryAgeRecommand OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Recommended battery life in month"
+ ::= { upsBaseBattery 4 }
+
+-- the upsAdvanceBattery group
+upsAdvanceBatteryCapacity OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery capacity expressed in percentage."
+ ::= { upsAdvanceBattery 1 }
+
+upsAdvanceBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery voltage expressed in 1/10 VDC."
+ ::= { upsAdvanceBattery 2 }
+
+upsAdvanceBatteryTemperature OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery temperature expressed in Celsius."
+ ::= { upsAdvanceBattery 3 }
+
+upsAdvanceBatteryRunTimeRemaining OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery remaining run time."
+ ::= { upsAdvanceBattery 4 }
+
+upsAdvanceBatteryReplaceIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBatteryNeedsReplacing(1),
+ batteryNeedsReplacing(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates if UPS batteries need to be replaced."
+ ::= { upsAdvanceBattery 5 }
+
+upsAdvanceBatteryFullChargeVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery charged voltage expressed in 1/10 VDC."
+ ::= { upsAdvanceBattery 6 }
+
+upsAdvanceBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery current expressed in percentage."
+ ::= { upsAdvanceBattery 7 }
+
+upsAdvanceBatteryVoltageRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The DC voltage rating of the battery set."
+ ::= { upsAdvanceBattery 8 }
+
+upsAdvanceBatteryLife OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The battery life expressed in 1/100 percentage."
+ ::= { upsAdvanceBattery 9 }
+
+
+-- the upsBaseInput group
+upsBaseInputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The AC input phase."
+ ::= { upsBaseInput 1 }
+
+
+-- the upsAdvanceInput group
+upsAdvanceInputLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input line voltage in 1/10 VAC."
+ ::= { upsAdvanceInput 1 }
+
+upsAdvanceInputMaxLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsAdvanceInput 2 }
+
+upsAdvanceInputMinLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsAdvanceInput 3 }
+
+upsAdvanceInputFrequency OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input line frequency in 1/10 Hz."
+ ::= { upsAdvanceInput 4 }
+
+upsAdvanceInputLineFailCause OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTransfer(1),
+ highLineVoltage(2),
+ brownout(3),
+ selfTest(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The reason of UPS power failure.
+ This value is set to:
+ - noTransfer(1), if UPS is in utility mode.
+ - highLineVoltage(2), if UPS switch to battery mode by reason of
+ input voltage over the high transfer vloltage.
+ - brownout(3), if UPS switch to battery mode by reason of
+ input voltage under the low transfer vloltage.
+ - selfTest(4), if the UPS was commanded to do a self test."
+ ::= { upsAdvanceInput 5 }
+
+upsAdvanceInputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ overVoltage(2),
+ underVoltage(3),
+ frequencyFailure(4),
+ blackout(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Display the present status of the utility power supplied to the UPS."
+ ::= { upsAdvanceInput 6 }
+
+
+-- the upsBaseOutput group
+upsBaseOutputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ onLine(2),
+ onBattery(3),
+ onBoost(4),
+ onSleep(5),
+ off(6),
+ rebooting(7),
+ onECO(8),
+ onBypass(9),
+ onBuck(10),
+ onOverload(11)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS output status."
+ ::= { upsBaseOutput 1 }
+
+upsBaseOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output phase."
+ ::= { upsBaseOutput 2 }
+
+upsBaseOutputWorkingFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The frequency of the UPS output power."
+ ::= { upsBaseOutput 3 }
+
+
+-- the upsAdvanceOutput group
+upsAdvanceOutputVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS output voltage in 1/10 VAC."
+ ::= { upsAdvanceOutput 1 }
+
+upsAdvanceOutputFrequency OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS output frequency in 1/10 Hz."
+ ::= { upsAdvanceOutput 2 }
+
+upsAdvanceOutputLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS output load expressed in percentage"
+ ::= { upsAdvanceOutput 3 }
+
+upsAdvanceOutputCurrent OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS output current in 1/10 Amps."
+ ::= { upsAdvanceOutput 4 }
+
+upsAdvanceOutputPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total output active power of the UPS system in W."
+ ::= { upsAdvanceOutput 5 }
+
+-- the upsBaseConfig group
+upsBaseConfigNumDevices OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of equipment plugged into the UPS."
+ ::= { upsBaseConfig 1 }
+
+upsBaseConfigDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of equipment plugged into the UPS.
+ The numbers of entries are given by the value of
+ upsBaseConfigNumDevices."
+ ::= { upsBaseConfig 2 }
+
+upsBaseConfigDeviceEntry OBJECT-TYPE
+ SYNTAX UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The equipment plugged in to the UPS."
+ INDEX { deviceIndex }
+ ::= { upsBaseConfigDeviceTable 1 }
+
+UpsBaseConfigDeviceEntry ::=
+ SEQUENCE {
+ deviceIndex
+ INTEGER,
+ deviceName
+ DisplayString,
+ vaRating
+ INTEGER,
+ acceptThisDevice
+ INTEGER
+ }
+
+deviceIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the equipment plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 1 }
+
+deviceName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the equipment plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 2 }
+
+vaRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The VA rating of the equipment plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 3 }
+
+acceptThisDevice OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An equipment is plugged if yes, unplugged if no."
+ ::= { upsBaseConfigDeviceEntry 4 }
+
+
+-- the upsAdvanceConfig group
+upsAdvanceConfigOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The standard UPS output voltage in VAC.
+ The possible values are 100, 110, 120, 127,
+ 208, 220, 230, and 240.
+ If a value other than a possible value is set,
+ it will not be accepted."
+ ::= { upsAdvanceConfig 1 }
+
+upsAdvanceConfigHighTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Adjust the high transfer vloltage in VAC.
+ The high transfer vloltage will become the UPS default value
+ subtracts this value. The allowed values depend on the output:
+ 100-127 volt system allow settings of 0-15.
+ 208-240 volt system allow settings of 0-30.
+ If the adjustable value is over the allowed values,
+ it will not be accepted."
+ ::= { upsAdvanceConfig 2 }
+
+upsAdvanceConfigLowTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Adjust the low transfer vloltage in VAC.
+ The low transfer vloltage will become the UPS default value
+ adds this value. The allowed values depend on the output:
+ 100-127 volt system allow settings of 0-15.
+ 208-240 volt system allow settings of 0-30.
+ If the adjustable value is over the allowed values,
+ it will not be accepted."
+ ::= { upsAdvanceConfig 3 }
+
+upsAdvanceConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ timed(1),
+ enable(2),
+ disable(3),
+ mute(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This value is set to handle audible alarms when power failure."
+ ::= { upsAdvanceConfig 4 }
+
+upsAdvanceConfigAlarmTimer OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time after power failure at which the UPS begins giving
+ audible alarms. This timer is effective only if the value of
+ upsAdvanceConfigAlarm is timed(1).
+ Accepted values are between 0 to 60 seconds.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 5 }
+
+upsAdvanceConfigMinReturnCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum battery capacity that UPS will return from
+ a low battery shutdown condition. The possible values
+ are between 0 to 40.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 6 }
+
+upsAdvanceConfigSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ low(2),
+ medium(3),
+ high(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The sensitivity of the UPS to power failure detection."
+ ::= { upsAdvanceConfig 7 }
+
+upsAdvanceConfigLowBatteryRunTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The desired run time, in seconds, UPS will enter in a
+ low battery sequence. The possible values are
+ 120, 300, 420, 600.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 8 }
+
+upsAdvanceConfigReturnDelay OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time the UPS will turn on after power recovery.
+ The value is also used in a 'reboot' or 'wake up' sequence.
+ The possible values are 0 to 600 seconds.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 9 }
+
+upsAdvanceConfigShutoffDelay OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time the UPS will remain on after receiving a
+ turn off command. The possible values are between 60 to
+ 5940 seconds.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 10 }
+
+upsAdvanceConfigSleepDelay OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay time the UPS will enter sleep mode after receiving
+ a sleep command. WThe possible values are between 60 to
+ 5940 seconds.
+ If a value other than a supported value is set, the value
+ will not be accepted."
+ ::= { upsAdvanceConfig 11 }
+
+
+upsAdvanceConfigSetEEPROMDefaults OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSetEEPROMDefaults(1),
+ setEEPROMDefaults(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reset the UPS EEPROM parameters to default values."
+ ::= { upsAdvanceConfig 12 }
+
+upsAdvanceConfigAutoRestore OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(1),
+ enable(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "When this option is enabled, the UPS will restore output
+ immediately when the utility power restores.When this option
+ is disabled, the UPS will not restore output at that moment
+ and users have to turn it on manually at a later time. "
+ ::= { upsAdvanceConfig 13 }
+
+
+upsAdvanceConfigRechargedCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " When the utility power restores, the UPS will start to recharge until
+ the specified battery capacity in percentage is met before restoring output power.
+ The possible values are 0, 15, 30, 45, 60, 75, and 90.
+ If a value other than a possible value is set, it will not be accepted."
+ ::= { upsAdvanceConfig 14 }
+
+
+upsAdvanceConfigColdStart OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(1),
+ enable(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " Set the ability of the UPS can start in the absence of input power.When
+ this option is enabled the UPS can be turned on without having input power."
+ ::= { upsAdvanceConfig 15 }
+
+
+upsAdvanceConfigDeepDischargeProtection OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " When the UPS is on Battery Mode with 0% load and the status remains for
+ the time configured,the RMCARD will enforce the UPS to Sleep Mode and
+ the output will be turned off. The possible values are 0, 20, 40, and 60 minutes.
+ If a value other than a possible value is set, it will not be accepted. "
+ ::= { upsAdvanceConfig 16 }
+
+
+
+upsAdvanceConfigSleepAfterAllClientShut OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(1),
+ enable(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If this option is enabled, UPS will enter sleep mode after
+ utility power failed and remaining MSDT+2 minutes.More information
+ about MSDT please reference to help page of UPS - > PowerPanel List."
+ ::= { upsAdvanceConfig 17 }
+
+
+upsAdvanceConfigLowBatteryThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "When the UPS supplies battery power and the remaining capacity is lower than this threshold,
+ the UPS will sound an alarm.
+ The value expressed in percentage."
+ ::= { upsAdvanceConfig 18 }
+
+
+-- the upsBaseControl group
+upsBaseControlConserveBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOffUps(1),
+ turnOffUpsToConserveBattery(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS on battery will enter sleeping when the variable is set
+ to turnOffUpsToConserveBattery(2). When utility power recovers
+ the UPS will turn back on. Trying to turn off a UPS that is
+ not on battery mode will cause badValue error.
+ It is no effective to set this value to noTurnOffUps(1)."
+ ::= { upsBaseControl 1 }
+
+
+-- the upsAdvanceControl group
+upsAdvanceControlUpsOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnUpsOff(1),
+ turnUpsOff(2),
+ turnUpsOffGracefully(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will shutdown when the variable is set to turnUpsOff(2).
+ UPS will shutdown after a delay period specified by
+ upsAdvanceConfigShutoffDelay when the variable is Set to
+ turnUpsOffGracefully(3).
+ Without regard to the utility state the UPS will not provide
+ output power in this state.
+ It is no effective to set this value to noTurnUpsOff(1)."
+ ::= { upsAdvanceControl 1 }
+
+upsAdvanceControlRebootUps OBJECT-TYPE
+ SYNTAX INTEGER {
+ noRebootUps(1),
+ rebootUps(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will shutdown and turn back on when the variable is
+ set to rebootUps(2).
+ It is no effective to set this value to noRebootUps(1)."
+ ::= { upsAdvanceControl 2 }
+
+upsAdvanceControlUpsSleep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPutUpsToSleep(1),
+ putUpsToSleep(2),
+ putUpsToSleepGracefully(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will enter sleep mode when the variable is set to putUpsToSleep(2).
+ UPS will enter sleep mode after a delay period specified by
+ upsAdvanceConfigSleepDelay when the variable is Set to
+ putUpsToSleepGracefully(3).
+ Without regard to the utility state the UPS will not provide output
+ power in sleep mode. Output power will recover when specified time
+ has elapsed.
+ It is no effective to set this value to noPutUpsToSleep(1)."
+ ::= { upsAdvanceControl 3 }
+
+upsAdvanceControlSimulatePowerFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSimulatePowerFailure(1),
+ simulatePowerFailure(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will transfer to backup mode when the variable is set
+ to simulatePowerFailure(2).
+ It is no effective to set this value to noFlashAndBeep(1)."
+ ::= { upsAdvanceControl 4 }
+
+upsAdvanceControlFlashAndBeep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFlashAndBeep(1),
+ flashAndBeep(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will beep and simultaneously turn on the panel lights
+ when the variable is set to flashAndBeep(2).
+ It is no effective to set this value to noSimulatePowerFailure(1)."
+ ::= { upsAdvanceControl 5 }
+
+upsAdvanceControlTurnOnUPS OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOnUPS(1),
+ turnOnUPS(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will turned on immediately when the variable is set
+ to turnOnUPS(2).
+ It is no effective to set this value to noTurnOnUPS(1)."
+ ::= { upsAdvanceControl 6 }
+
+upsAdvanceSleepAfterDelay OBJECT-TYPE
+ SYNTAX INTEGER (-1..600)
+ UNITS "seconds"
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will enter sleep mode after indicated number of seconds,
+ or less if the UPS batteries become depleted. Setting this
+ object to 0 will cause the shutdown to occur immediately.
+ Setting this object to -1 will abort the countdown."
+ ::= { upsAdvanceControl 7 }
+
+-- the upsTest group
+-- the upsAdvanceTest group
+upsAdvanceTestDiagnosticSchedule OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ biweekly(2),
+ weekly(3),
+ atTurnOn(4),
+ never(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The schedule of the UPS automatic selftest."
+ ::= { upsAdvanceTest 1 }
+
+upsAdvanceTestDiagnostics OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestDiagnostics(1),
+ testDiagnostics(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will do a diagnostic selftest when the variable is set
+ to testDiagnostics(2).
+ It is no effective to set this value to noTestDiagnostics(1)."
+ ::= { upsAdvanceTest 2 }
+
+upsAdvanceTestDiagnosticsResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ failed(2),
+ invalidTest(3),
+ testInProgress(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last UPS selftest result."
+ ::= { upsAdvanceTest 3 }
+
+upsAdvanceTestLastDiagnosticsDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last UPS selftest date in mm/dd/yy format."
+ ::= { upsAdvanceTest 4 }
+
+upsAdvanceTestIndicators OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will perform a panel indicator test when the variable
+ is set to testIndicators(2).
+ It is no effective to set this value to noTestIndicators(1)."
+ ::= { upsAdvanceTest 5 }
+
+upsAdvanceTestRuntimeEstimation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPerformEstimation(1),
+ performEstimation(2),
+ cancelCurrentEstimation(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS will discharge to calibrate the UPS runtime when the variable
+ is set to performEstimation(2).
+ This test runs until the UPS is in a low battery condition.
+ UPS will cancel the discharge after setting performEstimation(2)
+ when the variable is set to cancelCurrentEstimation(3).
+ It is no effective to set this value to noPerformEstimation(1).
+ The result of the runtime test will be stored in
+ upsAdvanceTestEstimationResults."
+ ::= { upsAdvanceTest 6 }
+
+upsAdvanceTestEstimationResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ invalidEstimation(2),
+ estimationInProgress(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last runtime estimation result.
+ This value means :
+ - ok(1), if a successful runtime estimation.
+ - invalidEstimation(2), if runtime estimation failure.
+ - estimationInProgress(3), if estimation is processing now."
+ ::= { upsAdvanceTest 7 }
+
+upsAdvanceTestEstimationDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last UPS runtime estimation date"
+ ::= { upsAdvanceTest 8 }
+
+-- the upsBankOutletControl grop
+upsBankOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBankOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the outlet banks."
+ ::= { upsBankOutletControl 1 }
+
+upsBankOutletControlEntry OBJECT-TYPE
+ SYNTAX UpsBankOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to control."
+ INDEX { upsBankControlIndex }
+ ::= { upsBankOutletControlTable 1 }
+
+UpsBankOutletControlEntry ::=
+ SEQUENCE {
+ upsBankControlIndex
+ INTEGER,
+ upsBankControlOutletCommand
+ INTEGER
+ }
+
+upsBankControlIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { upsBankOutletControlEntry 1 }
+
+upsBankControlOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOn (1),
+ immediateOff (2),
+ bankNotExist (3),
+ criticalBank (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet bank state. If
+ the outlet bank is on, the immediateOn (1) value will be returned.
+ If the outlet bank is off, the immediateOff (2) value will be
+ returned. If the outlet bank is critical (uncontrollable), the
+ criticalBank (4) value will be returned.
+ Setting this variable to immediateOn (1) will immediately turn
+ the outlet on.
+ Setting this variable to immediateOff (2) will immediately turn
+ the outlet off."
+ ::= { upsBankOutletControlEntry 2 }
+
+
+-- the upsPhase group
+-- the upsPhaseInput group in the upsPhase group
+upsPhaseInputTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase number."
+ ::= { upsPhaseInput 1 }
+
+-- the upsPhaseInputTable in upsPhaseInput group
+upsPhaseInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Phase Input in the UPS"
+ ::= { upsPhaseInput 2 }
+upsPhaseInputEntry OBJECT-TYPE
+ SYNTAX PhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS Phase Input Access."
+ INDEX { upsPhaseInputTableIndex}
+ ::= { upsPhaseInputTable 1 }
+
+ PhaseInputEntry ::=
+ SEQUENCE {
+ upsPhaseInputTableIndex INTEGER,
+ upsPhaseInputVoltage INTEGER,
+ upsPhaseInputCurrent INTEGER,
+ upsPhaseInputFrequency INTEGER,
+ upsPhaseInputPowerFactor INTEGER
+ }
+upsPhaseInputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(3)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the UPS Phase Input entry."
+ ::= { upsPhaseInputEntry 1 }
+
+upsPhaseInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the input voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
+ ::= { upsPhaseInputEntry 2 }
+
+upsPhaseInputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the input current that each phase of the UPS can provide. It is represented in 1/10 Amps."
+ ::= { upsPhaseInputEntry 3 }
+upsPhaseInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the input frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
+ ::= { upsPhaseInputEntry 4 }
+upsPhaseInputPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the input power factor that each phase of the UPS can provide. It is represented in 1/100."
+ ::= { upsPhaseInputEntry 5 }
+
+
+-- the upsPhaseOutput group in the upsPhase group
+upsPhaseOutputTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Phase number."
+ ::= { upsPhaseOutput 1 }
+
+-- the upsPhaseOutputTable in upsPhaseOutput group
+upsPhaseOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Phase Output in the UPS"
+ ::= { upsPhaseOutput 2 }
+
+upsPhaseOutputEntry OBJECT-TYPE
+ SYNTAX PhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS Phase Output Access."
+ INDEX { upsPhaseOutputTableIndex}
+ ::= { upsPhaseOutputTable 1 }
+
+ PhaseOutputEntry ::=
+ SEQUENCE {
+ upsPhaseOutputTableIndex INTEGER,
+ upsPhaseOutputVoltage INTEGER,
+ upsPhaseOutputCurrent INTEGER,
+ upsPhaseOutputFrequency INTEGER,
+ upsPhaseOutputPowerFactor INTEGER,
+ upsPhaseOutputPower INTEGER
+ }
+
+
+upsPhaseOutputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(3)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the UPS Phase Output entry."
+ ::= { upsPhaseOutputEntry 1 }
+
+upsPhaseOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the output voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
+ ::= { upsPhaseOutputEntry 2 }
+
+upsPhaseOutputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the output current that each phase of the UPS can provide. It is represented in 1/10 Amps."
+ ::= { upsPhaseOutputEntry 3 }
+upsPhaseOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the output frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
+ ::= { upsPhaseOutputEntry 4 }
+upsPhaseOutputPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the output power factor that each phase of the UPS can provide. It is represented in 1/100."
+ ::= { upsPhaseOutputEntry 5 }
+upsPhaseOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the output power that each phase of the UPS can provide. It is represented in Watt."
+ ::= { upsPhaseOutputEntry 6 }
+
+-- the upsPhaseBypass group in the upsPhase group
+upsPhaseBypassTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Phase number."
+ ::= { upsPhaseBypass 1 }
+
+-- the upsPhaseBypassTable in upsPhaseBypass group
+upsPhaseBypassTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PhaseBypassEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Phase Bypass in the UPS"
+ ::= { upsPhaseBypass 2 }
+
+upsPhaseBypassEntry OBJECT-TYPE
+ SYNTAX PhaseBypassEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS Phase Bypass Access."
+ INDEX { upsPhaseBypassTableIndex}
+ ::= { upsPhaseBypassTable 1 }
+
+ PhaseBypassEntry ::=
+ SEQUENCE {
+ upsPhaseBypassTableIndex INTEGER,
+ upsPhaseBypassVoltage INTEGER,
+ upsPhaseBypassCurrent INTEGER,
+ upsPhaseBypassFrequency INTEGER,
+ upsPhaseBypassPowerFactor INTEGER
+ }
+
+
+upsPhaseBypassTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(3)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the UPS Phase Bypass entry."
+ ::= { upsPhaseBypassEntry 1 }
+
+upsPhaseBypassVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bypass voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
+ ::= { upsPhaseBypassEntry 2 }
+
+upsPhaseBypassCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bypass current that each phase of the UPS can provide. It is represented in 1/10 Amps."
+ ::= { upsPhaseBypassEntry 3 }
+upsPhaseBypassFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bypass frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
+ ::= { upsPhaseBypassEntry 4 }
+upsPhaseBypassPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bypass power factor that each phase of the UPS can provide. It is represented in 1/100."
+ ::= { upsPhaseBypassEntry 5 }
+
+-- upsSystem Group
+upsStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ overheat (2),
+ hardwarefault (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS system status."
+ ::= { upsSystem 1 }
+
+-- the eswitch group
+-- the eSwitchIdent group
+eSwitchIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision set at the factory."
+ ::= { eSwitchIdent 1 }
+
+eSwitchIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision set at the factory."
+ ::= { eSwitchIdent 2 }
+
+eSwitchIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date in mm/dd/yy format."
+ ::= { eSwitchIdent 3 }
+
+eSwitchIdentModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The model name set at the factory.
+ This value need to consist with safty report."
+ ::= { eSwitchIdent 4 }
+
+
+-- the eSwitchBase group
+eSwitchNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numbers of switch have been attached to the system."
+ ::= { eSwitchBase 1 }
+
+eSwitchBaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESwitchBaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of switch information. The number of entries is given
+ by the value of eSwitchNumber."
+ ::= { eSwitchBase 2 }
+
+eSwitchBaseEntry OBJECT-TYPE
+ SYNTAX ESwitchBaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry information of the individual switch."
+ INDEX { eSwitchID}
+ ::= { eSwitchBaseTable 1 }
+
+ESwitchBaseEntry ::=
+ SEQUENCE {
+ eSwitchID
+ INTEGER,
+ eSwitchOutletNum
+ INTEGER,
+ eSwitchOutletState
+ DisplayString
+ }
+
+eSwitchID OBJECT-TYPE
+ SYNTAX INTEGER(0..16)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power switch ID number."
+ ::= { eSwitchBaseEntry 1 }
+
+eSwitchOutletNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlets provided in the switch."
+ ::= { eSwitchBaseEntry 2 }
+
+eSwitchOutletState OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will reply the status of all outlets in the switch.
+ '0' for outlet off, '1' for outlet on.
+ The index from left to right is outlet#8, #7, #6, #5, #4, #3, #2, #1.
+ For Example:
+ If the string is '01011010', it means the outlets status are the following:
+ outlet #8 is off,
+ outlet #7 is on,
+ outlet #6 is off,
+ outlet #5 is on,
+ outlet #4 is on,
+ outlet #3 is off,
+ outlet #2 is on,
+ outlet #1 is off.
+ "
+ ::= { eSwitchBaseEntry 3 }
+
+eSwitchBaseCtrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ESwitchBaseCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of switch control parameters. The number of entries is given
+ by the value of eSwitchNumber."
+ ::= { eSwitchBase 3 }
+
+eSwitchBaseCtrEntry OBJECT-TYPE
+ SYNTAX ESwitchBaseCtrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry control information of individual switches."
+ INDEX { eSwitchCtrID}
+ ::= { eSwitchBaseCtrTable 1 }
+
+ESwitchBaseCtrEntry ::=
+ SEQUENCE {
+ eSwitchCtrID
+ INTEGER,
+ eSwitchActOutlet
+ INTEGER,
+ eSwitchActType
+ INTEGER
+ }
+
+eSwitchCtrID OBJECT-TYPE
+ SYNTAX INTEGER(0..16)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Select the switch ID to be controlled."
+ ::= { eSwitchBaseCtrEntry 1 }
+
+eSwitchActOutlet OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The action outlets to be controlled."
+ ::= { eSwitchBaseCtrEntry 2 }
+
+eSwitchActType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The on/off type of the action outlets.
+ 1 for duration off, 2 for duration on,
+ 3 for immediately off, 4 for immediately on,
+ and 5 for reboot."
+ ::= { eSwitchBaseCtrEntry 3 }
+
+
+
+-- ePDU Group
+
+-- the ePDUIdent group
+
+ePDUIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the Rack PDU.
+ The maximum string size is device dependent."
+ ::= { ePDUIdent 1 }
+
+ePDUIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Rack PDU.
+ This value is set at the factory."
+ ::= { ePDUIdent 2 }
+
+ePDUIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8-byte ID string identifying the Rack PDU firmware revision.
+ This value is set at the factory."
+ ::= { ePDUIdent 3 }
+
+
+ePDUIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the Rack PDU was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. The year 2000 will be
+ represented by 00."
+ ::= { ePDUIdent 4 }
+
+ePDUIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 10-character string identifying the model number of
+ the Rack PDU. This value is set at the factory."
+ ::= { ePDUIdent 5 }
+
+ePDUIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 12-character string identifying the serial number of
+ the Rack PDU. This value is set at the factory."
+ ::= { ePDUIdent 6 }
+
+ePDUIdentDeviceRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the electrical rating of the device."
+
+ ::= { ePDUIdent 7 }
+
+ePDUIdentDeviceNumOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of outlets contained in the device."
+
+ ::= { ePDUIdent 8 }
+
+ePDUIdentDeviceNumPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of phases supported by the device."
+
+ ::= { ePDUIdent 9 }
+
+ePDUIdentDeviceNumBreakers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of circuit breakers supported by the device.
+ This is the same as the number of banks of outlets.
+ 0 will be returned if the unit has no phase breakers. "
+
+ ::= { ePDUIdent 10 }
+
+ePDUIdentDeviceBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return rating of the circuit breakers on the device if it has any."
+
+ ::= { ePDUIdent 11 }
+
+ePDUIdentDeviceOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ orientHorizontal (1),
+ orientVertical (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the intended physical orientation of the device.
+
+ OrientHorizonatal(1) indicates Horizontal.
+ OrientVertical(2) indicates Vertical."
+
+ ::= { ePDUIdent 12 }
+
+ePDUIdentDeviceOutletLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhaseToNeutral (1),
+ seqPhaseToPhase (2),
+ seqPhToNeu21PhToPh (3),
+ seqPhToPhGrouped (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return outlet layout for the device.
+
+ SeqPhaseToNeutral(1) indicates outlet layout as follows:
+ 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
+
+ SeqPhaseToPhase(2) indicates outlet layout as follows:
+ 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
+
+ SeqPhToNeu21PhToPh(3) indicates outlet layout as follows:
+ 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
+
+ SeqPhToPhGrouped(4) indicates outlet layout as follows:
+ Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2)."
+ ::= { ePDUIdent 13 }
+
+ePDUIdentDeviceDisplayOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ displayNormal (1),
+ displayReverse (2),
+ displayRotate90 (3),
+ displayRotate270 (4),
+ displayAuto (5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the intended physical orientation of the Seven-Segment Display.
+
+ displayNormal(1) indicates Normal.
+ displayReverse(2)indicates Upside-Down.
+ displayRotate90(3) indicates rotate 90 degree.
+ displayRotate270(4) indicates rotate 270 degree.
+ displayAuto(5) indicates auto-detect and rotate."
+
+ ::= { ePDUIdent 14 }
+
+
+ePDUIdentDeviceLinetoLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting/Setting this OID will return/set the Line to Line Volatage.
+
+ The valid range is between 0V to 440V"
+
+ ::= { ePDUIdent 15 }
+
+ePDUIdentIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "PDU will perform a panel indicator test when the variable
+ is set to testIndicators(2).
+
+ It is no effective to set this value to noTestIndicators(1)."
+
+ ::= { ePDUIdent 16 }
+
+-- the ePDULoadDevice group
+
+ePDULoadDevMaxPhaseLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each phase of the Rack PDU can provide. It is
+ represented in Amps.
+
+ 0 will be returned if the unit is banked."
+ ::= { ePDULoadDevice 1 }
+
+ePDULoadDevNumPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of phases available with this Rack PDU."
+ ::= { ePDULoadDevice 2 }
+
+ePDULoadDevMaxBankLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that a bank of the Rack PDU can provide. It is
+ represented in Amps.
+
+ 0 will be returned if the device does not have any banks."
+
+ ::= { ePDULoadDevice 3 }
+
+ePDULoadDevNumBanks OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of banks of outlets available with this Rack PDU.
+ A bank of outlets has a unique circuit breaker for a subset
+ of the total number of outlets on the ePDU.
+
+ 0 will be returned if the unit no banks."
+ ::= { ePDULoadDevice 4 }
+
+ePDULoadDevBankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Bank Table."
+ ::= { ePDULoadDevice 5 }
+
+
+ePDULoadDevBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadDevBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Bank Max Load in the Rack PDU."
+
+ ::= { ePDULoadDevice 6 }
+
+ePDULoadDevBankEntry OBJECT-TYPE
+ SYNTAX LoadDevBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU Banks Access."
+ INDEX { ePDULoadDevBankIndex}
+ ::= { ePDULoadDevBankTable 1 }
+
+LoadDevBankEntry ::=
+ SEQUENCE {
+ ePDULoadDevBankIndex INTEGER,
+ ePDULoadDevBankNumber INTEGER,
+ ePDULoadDevBankMaxLoad INTEGER
+ }
+
+ePDULoadDevBankIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank entry."
+ ::= { ePDULoadDevBankEntry 1 }
+
+ePDULoadDevBankNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bank number."
+
+ ::= { ePDULoadDevBankEntry 2 }
+
+ePDULoadDevBankMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each bank of the Rack PDU can provide. It is
+ represented in Amps."
+
+ ::= { ePDULoadDevBankEntry 3 }
+
+ePDULoadDevMaxOutletTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Outlet Table."
+ ::= { ePDULoadDevice 7 }
+
+
+ePDULoadDevMaxOutletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadDevMaxOutletEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU."
+ ::= { ePDULoadDevice 8 }
+
+ePDULoadDevMaxOutletEntry OBJECT-TYPE
+ SYNTAX LoadDevMaxOutletEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to Max Outlet Load of an Outlet Monitored Rack PDU"
+ INDEX { ePDULoadDevOutletIndex}
+ ::= { ePDULoadDevMaxOutletTable 1 }
+
+LoadDevMaxOutletEntry ::=
+ SEQUENCE {
+ ePDULoadDevOutletIndex INTEGER,
+ ePDULoadDevOutletNumber INTEGER,
+ ePDULoadDevMaxOutletLoad INTEGER
+ }
+
+ePDULoadDevOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Outlet Monitored Rack PDU Max Outlet Load entry."
+ ::= { ePDULoadDevMaxOutletEntry 1 }
+
+ePDULoadDevOutletNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Outlet number."
+ ::= { ePDULoadDevMaxOutletEntry 2 }
+
+
+ePDULoadDevMaxOutletLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each Outlet of an Outlet Monitored Rack PDU can provide. It is
+ represented in Amps. "
+ ::= { ePDULoadDevMaxOutletEntry 3 }
+
+
+-- the ePDULoadPhaseConfig group
+
+ePDULoadPhaseConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadPhaseConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each Rack PDU phase.
+ The number of entries is contained in the
+ ePDULoadDevNumPhases OID."
+ ::= { ePDULoadPhaseConfig 1 }
+
+ePDULoadPhaseConfigEntry OBJECT-TYPE
+ SYNTAX LoadPhaseConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU phase to configure."
+ INDEX { ePDULoadPhaseConfigIndex}
+ ::= { ePDULoadPhaseConfigTable 1 }
+
+LoadPhaseConfigEntry ::=
+ SEQUENCE {
+ ePDULoadPhaseConfigIndex INTEGER,
+ ePDULoadPhaseConfigLowLoadThreshold INTEGER,
+ ePDULoadPhaseConfigNearOverloadThreshold INTEGER,
+ ePDULoadPhaseConfigOverloadThreshold INTEGER,
+ ePDULoadPhaseConfigAlarm INTEGER
+ }
+
+ePDULoadPhaseConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase entry."
+ ::= { ePDULoadPhaseConfigEntry 1 }
+
+ePDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in Amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 Amps effectively disables this
+ warning.
+
+ Maximum value must be less than the value returned
+ by the ePDULoadPhaseConfigNearOverloadThreshold OID."
+ ::= { ePDULoadPhaseConfigEntry 2 }
+
+ePDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than the value returned by
+ the ePDULoadPhaseConfigLowLoadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDULoadPhaseConfigOverloadThreshold OID."
+ ::= { ePDULoadPhaseConfigEntry 3 }
+
+ePDULoadPhaseConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than or equal to the value
+ returned by the ePDULoadPhaseConfigNearOverloadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDULoadDevMaxPhaseLoad OID."
+ ::= { ePDULoadPhaseConfigEntry 4 }
+
+
+ePDULoadPhaseConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLoadAlarm (1),
+ underCurrentAlarm (2),
+ nearOverCurrentAlarm (3),
+ overCurrentAlarm (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the current Phase Alarm."
+ ::= { ePDULoadPhaseConfigEntry 5 }
+
+
+-- the ePDULoadStatus group
+
+ePDULoadStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of each Rack PDU phase/bank.
+ The number of entries is calculated by adding
+ the number of phases (ePDULoadDevNumPhases OID) and
+ the number of banks of outlets (ePDULoadDevNumBanks)
+ Number of entries = #phases + #banks.
+ NOTE: If a device has phase and bank information, all phase information
+ shall precede the bank information."
+ ::= { ePDULoadStatus 1 }
+
+ePDULoadStatusEntry OBJECT-TYPE
+ SYNTAX LoadStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU phase/bank to gather status from."
+ INDEX { ePDULoadStatusIndex}
+ ::= { ePDULoadStatusTable 1 }
+
+LoadStatusEntry ::=
+ SEQUENCE {
+ ePDULoadStatusIndex INTEGER,
+ ePDULoadStatusLoad Gauge,
+ ePDULoadStatusLoadState INTEGER,
+ ePDULoadStatusPhaseNumber INTEGER,
+ ePDULoadStatusBankNumber INTEGER,
+ ePDULoadStatusVoltage INTEGER,
+ ePDULoadStatusActivePower INTEGER,
+ ePDULoadStatusApparentPower INTEGER,
+ ePDULoadStatusPowerFactor INTEGER,
+ ePDULoadStatusEnergy INTEGER,
+ ePDULoadStatusEnergyStartTime DisplayString
+ }
+
+ePDULoadStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase/bank entry. All phase information will precede
+ any bank information"
+ ::= { ePDULoadStatusEntry 1 }
+
+ePDULoadStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank load measured
+ in tenths of Amps."
+ ::= { ePDULoadStatusEntry 2 }
+
+ePDULoadStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ loadNormal (1),
+ loadLow (2),
+ loadNearOverload (3),
+ loadOverload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank load state.
+
+ loadNormal(1) indicates that the phase/bank is operating
+ properly within the ePDULoadConfigLowLoadThreshold
+ and ePDULoadConfigNearOverloadThreshold OID values.
+
+ loadLow(2) indicates that the phase/bank load has dropped
+ below the ePDULoadConfigLowLoadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ loadNearOverload(3) indicates that the phase/bank load is
+ greater than or equal to the ePDULoadConfigNearOverloadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ loadOverload(4) indicates that the phase/bank load is greater
+ than or equal to the ePDULoadConfigOverloadThreshold
+ OID value.
+
+ An SNMP trap will occur when this state is entered or cleared."
+ ::= { ePDULoadStatusEntry 3 }
+
+ePDULoadStatusPhaseNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase number to which this record refers."
+ ::= { ePDULoadStatusEntry 4 }
+
+ePDULoadStatusBankNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank number to which this record refers. A value of 0 will be returned if
+ any bank is not present or if it is phase related."
+ ::= { ePDULoadStatusEntry 5 }
+
+ePDULoadStatusVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank voltage measured
+ in 0.1 volts."
+ ::= { ePDULoadStatusEntry 6 }
+
+ePDULoadStatusActivePower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank active power measured
+ in watts."
+ ::= { ePDULoadStatusEntry 7 }
+
+ePDULoadStatusApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank apparent power measured
+ in VA."
+ ::= { ePDULoadStatusEntry 8 }
+
+ePDULoadStatusPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return power factor of the output measured in hundredths.
+ A value of 100 representing a unity power factor (1.00)."
+ ::= { ePDULoadStatusEntry 9 }
+
+ePDULoadStatusEnergy OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank apparent power measured
+ in 0.1 kilowatt-hours."
+ ::= { ePDULoadStatusEntry 10 }
+
+ePDULoadStatusEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the date and time of the last energy
+ meter reset"
+ ::= { ePDULoadStatusEntry 11 }
+
+-- the ePDULoadBankConfig group
+
+ePDULoadBankConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadBankConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each Rack PDU bank.
+ The number of entries is contained in the
+ ePDULoadDevNumBanks OID."
+ ::= { ePDULoadBankConfig 1 }
+
+ePDULoadBankConfigEntry OBJECT-TYPE
+ SYNTAX LoadBankConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU bank to configure."
+ INDEX { ePDULoadBankConfigIndex}
+ ::= { ePDULoadBankConfigTable 1 }
+
+LoadBankConfigEntry ::=
+ SEQUENCE {
+ ePDULoadBankConfigIndex INTEGER,
+ ePDULoadBankConfigLowLoadThreshold INTEGER,
+ ePDULoadBankConfigNearOverloadThreshold INTEGER,
+ ePDULoadBankConfigOverloadThreshold INTEGER,
+ ePDULoadBankConfigAlarm INTEGER
+ }
+
+ePDULoadBankConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank entry."
+ ::= { ePDULoadBankConfigEntry 1 }
+
+ePDULoadBankConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in Amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 Amps effectively disables this
+ warning.
+
+ Maximum value must be less than the value returned
+ by the ePDULoadBankConfigNearOverloadThreshold OID."
+
+ ::= { ePDULoadBankConfigEntry 2 }
+
+ePDULoadBankConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than the value returned by
+ the ePDULoadBankConfigLowLoadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDULoadBankConfigOverloadThreshold OID."
+
+ ::= { ePDULoadBankConfigEntry 3 }
+
+ePDULoadBankConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than or equal to the value
+ returned by the ePDULoadBankConfigNearOverloadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDULoadDevMaxBankLoad OID."
+
+ ::= { ePDULoadBankConfigEntry 4 }
+
+ePDULoadBankConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLoadAlarm (1),
+ underCurrentAlarm (2),
+ nearOverCurrentAlarm (3),
+ overCurrentAlarm (4)
+
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " Getting this OID will return the current Bank Alarm."
+ ::= { ePDULoadBankConfigEntry 5 }
+
+
+-- the ePDUOutletDevice group
+
+ePDUOutletDevCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandAll (1),
+ immediateAllOn (2),
+ immediateAllOff (3),
+ immediateAllReboot (4),
+ delayedAllOn (5),
+ delayedAllOff (6),
+ delayedAllReboot (7),
+ cancelAllPendingCommands (8)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOn (2) will turn all outlets
+ on immediately.
+
+ Setting this OID to immediateAllOff (3) will turn all outlets
+ off immediately.
+
+ Setting this OID to immediateAllReboot (4) will reboot all outlets
+ immediately.
+
+ Setting this OID to delayedAllOn (5) will turn all outlets on as
+ defined by each outlet's ePDUOutletConfigPowerOnTime OID value.
+
+ Setting this OID to delayedAllOff (6) will turn all outlets
+ off as defined by each outlet's ePDUOutletConfigPowerOffTime OID value.
+
+ Setting this OID to delayedAllReboot (7) will cause a
+ delayedAllOff command to be performed. Once all outlets are off,
+ the Switched Rack PDU will then delay the largest
+ ePDUOutletConfigRebootDuration OID time, and then perform a
+ delayedAllOn command.
+
+ Setting this OID to cancelAllPendingCommands (8) will cause all pending
+ commands on the Switched Rack PDU to be canceled.
+
+ Getting this OID will return the noCommandAll (1) value."
+ ::= { ePDUOutletDevice 1 }
+
+ePDUOutletDevColdstartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of delay, in seconds, between when
+ power is provided to the Switched Rack PDU and
+ when the Switched Rack PDU provides basic master
+ power to the outlets.
+
+ Allowed values are:
+
+ -1 - never apply power automatically.
+ 0 - apply power immediately.
+ 1 to 300 - delay up to 300 seconds (5 minutes)."
+ ::= { ePDUOutletDevice 2 }
+
+ePDUOutletDevNumCntrlOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of controlled outlets on this Switched Rack PDU."
+ ::= { ePDUOutletDevice 3 }
+
+ePDUOutletDevNumTotalOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of outlets on this Rack PDU."
+ ::= { ePDUOutletDevice 4 }
+
+ePDUOutletDevMonitoredOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of monitored outlets on this Rack PDU."
+ ::= { ePDUOutletDevice 5 }
+
+ePDUOutletDevColdstartState OBJECT-TYPE
+ SYNTAX INTEGER {
+ allOn (1),
+ previous (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ePDU outlet state after coldstart.
+ Allowed values are:
+ 1 - all outlets on after coldstart.
+ 2 - outlet status same as previous state."
+ ::= { ePDUOutletDevice 6 }
+
+-- the ePDUOutletPhase group
+
+ePDUOutletPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for management of outlets on a per phase basis."
+ ::= { ePDUOutletPhase 1 }
+
+ePDUOutletPhaseEntry OBJECT-TYPE
+ SYNTAX OutletPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The phase to manage."
+ INDEX { ePDUOutletPhaseIndex}
+ ::= { ePDUOutletPhaseTable 1 }
+
+OutletPhaseEntry ::=
+ SEQUENCE {
+ ePDUOutletPhaseIndex INTEGER,
+ ePDUOutletPhaseOverloadRestriction INTEGER
+ }
+
+ePDUOutletPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Switched Rack PDU phase entry."
+ ::= { ePDUOutletPhaseEntry 1 }
+
+ePDUOutletPhaseOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ phase when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding phase to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigOverloadThreshold OID is exceeded."
+ ::= { ePDUOutletPhaseEntry 2 }
+
+
+
+-- the ePDUOutletControl group
+
+ePDUOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDUOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the individual outlets.
+ The number of entries is contained in the
+ ePDUOutletDevNumCntrlOutlets OID."
+ ::= { ePDUOutletControl 1 }
+
+ePDUOutletControlEntry OBJECT-TYPE
+ SYNTAX EPDUOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to control."
+ INDEX { ePDUOutletControlIndex}
+ ::= { ePDUOutletControlTable 1 }
+
+EPDUOutletControlEntry ::=
+ SEQUENCE {
+ ePDUOutletControlIndex INTEGER,
+ ePDUOutletControlOutletName DisplayString,
+ ePDUOutletControlOutletPhase INTEGER,
+ ePDUOutletControlOutletCommand INTEGER,
+ ePDUOutletControlOutletBank INTEGER
+ }
+
+ePDUOutletControlIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { ePDUOutletControlEntry 1 }
+
+ePDUOutletControlOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ An error will be returned if the set request exceeds the max size.
+ This OID is provided for informational purposes only."
+ ::= { ePDUOutletControlEntry 2 }
+
+ePDUOutletControlOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { ePDUOutletControlEntry 3 }
+
+ePDUOutletControlOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOn (1),
+ immediateOff (2),
+ immediateReboot (3),
+ delayedOn (4),
+ delayedOff (5),
+ delayedReboot (6),
+ cancelPendingCommand (7),
+ outletIdentify (8)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOn (1) value will be returned.
+ If the outlet is off, the immediateOff (2) value will be
+ returned.
+
+
+ Setting this variable to immediateOn (1) will immediately turn
+ the outlet on.
+
+ Setting this variable to immediateOff (2) will immediately turn
+ the outlet off.
+
+ Setting this variable to immediateReboot (3) will immediately
+ reboot the outlet.
+
+ Setting this variable to delayedOn (4) will turn the outlet on
+ after the ePDUOutletConfigPowerOnTime OID time has elapsed.
+
+ Setting this variable to delayedOff (5) will turn the outlet off
+ after the ePDUOutletConfigPowerOffTime OID time has elapsed.
+
+ Setting this variable to delayedReboot (6) will cause the
+ Switched Rack PDU to perform a delayedOff command, wait the
+ ePDUOutletConfigRebootDuration OID time, and then perform a
+ delayedOn command.
+
+ Setting this variable to cancelPendingCommand (7) will cause any
+ pending command to this outlet to be canceled.
+
+ Setting this variable to outletIdentify (8) will cause PDU LED
+ to display the number of the outlet."
+
+ ::= { ePDUOutletControlEntry 4 }
+
+ePDUOutletControlOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { ePDUOutletControlEntry 5 }
+
+
+
+-- the ePDUOutletConfig group
+
+ePDUOutletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the ePDUOutletDevNumCntrlOutlets OID."
+ ::= { ePDUOutletConfig 1 }
+
+ePDUOutletConfigEntry OBJECT-TYPE
+ SYNTAX EPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to configure."
+ INDEX { ePDUOutletConfigIndex}
+ ::= { ePDUOutletConfigTable 1 }
+
+EPDUOutletConfigEntry ::=
+ SEQUENCE {
+ ePDUOutletConfigIndex INTEGER,
+ ePDUOutletConfigOutletName DisplayString,
+ ePDUOutletConfigOutletPhase INTEGER,
+ ePDUOutletConfigPowerOnTime INTEGER,
+ ePDUOutletConfigPowerOffTime INTEGER,
+ ePDUOutletConfigRebootDuration INTEGER,
+ ePDUOutletConfigOutletBank INTEGER
+ }
+
+ePDUOutletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { ePDUOutletConfigEntry 1 }
+
+ePDUOutletConfigOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ An error will be returned if the set request exceeds the max size."
+ ::= { ePDUOutletConfigEntry 2 }
+
+ePDUOutletConfigOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { ePDUOutletConfigEntry 3 }
+
+ePDUOutletConfigPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on at coldstart or when a command that requires
+ a turn-on delay is issued.
+
+ Allowed values are:
+
+ -1 - never power on.
+ 0 - power on immediately.
+ 1 to 7200 - power on up to 7200 seconds after being
+ commanded."
+ ::= { ePDUOutletConfigEntry 4 }
+
+ePDUOutletConfigPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off when a command that requires
+ a turn-off delay is issued.
+
+ Allowed values are:
+
+ -1 - never power off.
+ 0 - power off immediately.
+ 1 to 7200 - power off up to 7200 seconds after being
+ commanded."
+ ::= { ePDUOutletConfigEntry 5 }
+
+ePDUOutletConfigRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed range is any value between 5 and 60 seconds (1 minute)."
+ ::= { ePDUOutletConfigEntry 6 }
+
+ePDUOutletConfigOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { ePDUOutletConfigEntry 7 }
+
+
+-- Monitored Outlets table
+
+ePDUOutletConfigMonitoredTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Outlet Config Monitored Table"
+ ::= { ePDUOutletConfig 2 }
+
+
+ePDUOutletConfigMonitoredTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigMonitoredEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU."
+ ::= { ePDUOutletConfig 3 }
+
+ePDUOutletConfigMonitoredEntry OBJECT-TYPE
+ SYNTAX OutletConfigMonitoredEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to Monitored Outlet entries"
+ INDEX { ePDUOutletConfigMonitoredIndex }
+ ::= { ePDUOutletConfigMonitoredTable 1 }
+
+OutletConfigMonitoredEntry ::=
+ SEQUENCE {
+ ePDUOutletConfigMonitoredIndex INTEGER,
+ ePDUOutletConfigMonitoredName DisplayString,
+ ePDUOutletConfigMonitoredNumber INTEGER,
+ ePDUOutletConfigMonitoredLowLoadThreshold INTEGER,
+ ePDUOutletConfigMonitoredNearOverloadThreshold INTEGER,
+ ePDUOutletConfigMonitoredOverloadThreshold INTEGER,
+ ePDUOutletConfigMonitoredPeakLoadReset INTEGER,
+ ePDUOutletConfigMonitoredEnergyReset INTEGER
+ }
+
+ePDUOutletConfigMonitoredIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the RACK PDU Phase entry."
+ ::= { ePDUOutletConfigMonitoredEntry 1 }
+
+ePDUOutletConfigMonitoredName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the Monitored Outlet. The maximum string size is device dependent.
+ An error will be returned if the set request exceeds the max size."
+ ::= { ePDUOutletConfigMonitoredEntry 2 }
+
+ePDUOutletConfigMonitoredNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet number of an Outlet Monitored RACK PDU."
+ ::= { ePDUOutletConfigMonitoredEntry 3 }
+
+
+ePDUOutletConfigMonitoredLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in watts. A warning will be issued when
+ the load is less than the threshold value.
+
+ A threshold value of 0 effectively disables this
+ warning.
+
+ Maximum value must be less than the value returned
+ by the ePDUOutletConfigMonitoredNearOverloadThreshold OID.
+
+ 0 will be returned if the unit is not Outlet Monitored Rack PDU."
+ ::= { ePDUOutletConfigMonitoredEntry 4 }
+
+ePDUOutletConfigMonitoredNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in watts. A warning
+ will be issued when the load is greater than or equal
+ to the threshold value.
+
+ Minimum value must be greater than the value returned by
+ the ePDUOutletConfigMonitoredLowLoadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDUOutletConfigMonitoredOverloadThreshold OID.
+
+ 0 will be returned if the unit is not Outlet Monitored Rack PDU."
+ ::= { ePDUOutletConfigMonitoredEntry 5 }
+
+ePDUOutletConfigMonitoredOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in watts. A warning
+ will be issued when the load is greater than or equal
+ to the threshold value.
+
+ Minimum value must be greater than or equal to the value
+ returned by the ePDUOutletConfigMonitoredNearOverloadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the ePDULoadDevMaxOutletLoad OID.
+
+ 0 will be returned if the unit is not Outlet Monitored Rack PDU."
+ ::= { ePDUOutletConfigMonitoredEntry 6 }
+
+ePDUOutletConfigMonitoredPeakLoadReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAction (1),
+ reset (2),
+ notSupport (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the existing peak power value
+ to be replaced by the current load power value.
+
+ Getting this oid will do nothing and return noAction (1) if the PDU
+ support this feature, return notSupport (3) if the PDU do not support
+ this feature. "
+ ::= { ePDUOutletConfigMonitoredEntry 7 }
+
+ePDUOutletConfigMonitoredEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAction (1),
+ reset (2),
+ notSupport (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the device energy meter value
+ to be reset to zero.
+
+ Getting this oid will do nothing and return noAction (1) if the PDU
+ support this feature, return notSupport (3) if the PDU do not support
+ this feature. "
+ ::= { ePDUOutletConfigMonitoredEntry 8 }
+
+
+-- the ePDUOutletStatus group
+
+ePDUOutletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDUOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of individual outlets. The number of
+ entries is contained in the ePDUOutletDevNumCntrlOutlets OID."
+ ::= { ePDUOutletStatus 1 }
+
+ePDUOutletStatusEntry OBJECT-TYPE
+ SYNTAX EPDUOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to gather status from."
+ INDEX { ePDUOutletStatusIndex}
+ ::= { ePDUOutletStatusTable 1 }
+
+EPDUOutletStatusEntry ::=
+ SEQUENCE {
+ ePDUOutletStatusIndex INTEGER,
+ ePDUOutletStatusOutletName DisplayString,
+ ePDUOutletStatusOutletPhase INTEGER,
+ ePDUOutletStatusOutletState INTEGER,
+ ePDUOutletStatusCommandPending INTEGER,
+ ePDUOutletStatusOutletBank INTEGER,
+ ePDUOutletStatusLoad Gauge,
+ ePDUOutletStatusActivePower Gauge,
+ ePDUOutletStatusAlarm INTEGER,
+ ePDUOutletStatusPeakPower Gauge,
+ ePDUOutletStatusPeakPowerTime DisplayString,
+ ePDUOutletStatusPeakPowerStart DisplayString,
+ ePDUOutletStatusEnergy Gauge,
+ ePDUOutletStatusEnergyStartTime DisplayString
+ }
+
+ePDUOutletStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { ePDUOutletStatusEntry 1 }
+
+ePDUOutletStatusOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ This OID is provided for informational purposes only."
+ ::= { ePDUOutletStatusEntry 2 }
+
+ePDUOutletStatusOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { ePDUOutletStatusEntry 3 }
+
+ePDUOutletStatusOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusOn (1),
+ outletStatusOff (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletStatusOn (1) value will be returned.
+ If the outlet is off, the outletStatusOff (2) value will be
+ returned."
+ ::= { ePDUOutletStatusEntry 4 }
+
+ePDUOutletStatusCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusCommandPending (1),
+ outletStatusNoCommandPending (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet. If a command is pending on the
+ outlet, the outletStatusCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet, the outletStatusNoCommandPending (2)
+ will be returned."
+ ::= { ePDUOutletStatusEntry 5 }
+
+ePDUOutletStatusOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { ePDUOutletStatusEntry 6 }
+
+ePDUOutletStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
+ in tenths of Amps."
+ ::= { ePDUOutletStatusEntry 7 }
+
+ePDUOutletStatusActivePower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
+ in watts"
+ ::= { ePDUOutletStatusEntry 8 }
+
+ePDUOutletStatusAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLoadAlarm (1),
+ underCurrentAlarm (2),
+ nearOverCurrentAlarm (3),
+ overCurrentAlarm (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the current outlet alarm"
+ ::= { ePDUOutletStatusEntry 9 }
+
+ePDUOutletStatusPeakPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak power consumption of the Rack PDU load in watts.
+ This value can be reset by setting the oid
+ ePDUOutletConfigMonitoredPeakLoadReset to reset (2)"
+ ::= { ePDUOutletStatusEntry 10 }
+
+ePDUOutletStatusPeakPowerTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the date and time that peak power consumption occurred"
+ ::= { ePDUOutletStatusEntry 11 }
+
+ePDUOutletStatusPeakPowerStart OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the date and time that peak power consumption started"
+ ::= { ePDUOutletStatusEntry 12 }
+
+ePDUOutletStatusEnergy OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Energy meter measuring Rack PDU load energy consumption
+ in tenths of kilowatt-hours. This value can be reset by setting
+ the oid ePDUOutletConfigMonitoredEnergyReset to reset (2)"
+ ::= { ePDUOutletStatusEntry 13 }
+
+ePDUOutletStatusEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last device energy
+ meter reset"
+ ::= { ePDUOutletStatusEntry 14 }
+
+
+-- the ePDUOutletBank group
+
+ePDUOutletBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for management of outlets on a per bank basis."
+ ::= { ePDUOutletBank 1 }
+
+ePDUOutletBankEntry OBJECT-TYPE
+ SYNTAX OutletBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The bank to manage."
+ INDEX { ePDUOutletBankIndex}
+ ::= { ePDUOutletBankTable 1 }
+
+OutletBankEntry ::=
+ SEQUENCE {
+ ePDUOutletBankIndex INTEGER,
+ ePDUOutletBankOverloadRestriction INTEGER
+ }
+
+ePDUOutletBankIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Switched Rack PDU bank entry."
+ ::= { ePDUOutletBankEntry 1 }
+
+ePDUOutletBankOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ bank when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding bank to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding bank to turn on if the
+ ePDULoadBankConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding bank to turn on if the
+ ePDULoadBankConfigOverloadThreshold OID is exceeded."
+ ::= { ePDUOutletBankEntry 2 }
+
+
+-- the ePDUPowerSupplyDevice group
+
+ePDUPowerSupply1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupplyOneOk (1),
+ powerSupplyOneFailed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return powerSupply1Ok(1) if power
+ supply 1 is functioning normally. If not functioning normally,
+ this OID will return powerSupply1Failed(2)."
+ ::= { ePDUPowerSupplyDevice 1 }
+
+ePDUPowerSupply2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupplyTwoOk (1),
+ powerSupplyTwoFailed (2),
+ powerSupplyTwoNotPresent (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return powerSupply2Ok(1) if power
+ supply 2 is functioning normally. If not functioning normally,
+ this OID will return powerSupply2Failed(2).
+
+ Metered Rack PDUs do not have a redundant powersupply."
+
+ ::= { ePDUPowerSupplyDevice 2 }
+
+ePDUPowerSupplyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ allAvailablePowerSuppliesOK (1),
+ powerSupplyOneFailed (2),
+ powerSupplyTwoFailed (3),
+ powerSupplyOneandTwoFailed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return powerSupply Alarm"
+ ::= { ePDUPowerSupplyDevice 3 }
+
+
+-- the ePDUStatus group
+
+ePDUStatusBankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Status Bank Table"
+ ::= { ePDUStatus 1 }
+
+
+ePDUStatusBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of each Rack PDU Bank"
+ ::= { ePDUStatus 2 }
+
+ePDUStatusBankEntry OBJECT-TYPE
+ SYNTAX BankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to Bank entries"
+ INDEX { ePDUStatusBankIndex }
+ ::= { ePDUStatusBankTable 1 }
+
+BankEntry ::=
+ SEQUENCE {
+ ePDUStatusBankIndex INTEGER,
+ ePDUStatusBankNumber INTEGER,
+ ePDUStatusBankState INTEGER
+ }
+
+ePDUStatusBankIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the RACK PDU Bank entry."
+ ::= { ePDUStatusBankEntry 1 }
+
+ePDUStatusBankNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bank number."
+ ::= { ePDUStatusBankEntry 2 }
+
+ePDUStatusBankState OBJECT-TYPE
+ SYNTAX INTEGER {
+ bankLoadNormal (1),
+ bankLoadLow (2),
+ bankLoadNearOverload (3),
+ bankLoadOverload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bank load state.
+
+ bankLoadNormal(1) indicates that the bank is
+ operating properly within the ePDULoadBankConfigLowLoadThreshold
+ and ePDULoadBankConfigNearOverloadThreshold OID values.
+
+ bankLoadLow(2) indicates that the bank load has
+ dropped below the ePDULoadBankConfigLowLoadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ bankLoadNearOverload(3) indicates that the bank load
+ is greater than or equal to the
+ ePDULoadBankConfigNearOverloadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ bankLoadOverload(4) indicates that the bank load is
+ greater than or equal to the ePDULoadBankConfigOverloadThreshold
+ OID value.
+ An SNMP trap will occur when this state is entered or cleared."
+ ::= { ePDUStatusBankEntry 3 }
+
+-- Phase status table
+
+ePDUStatusPhaseTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Status Phase Table"
+ ::= { ePDUStatus 3 }
+
+
+ePDUStatusPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of each Rack PDU Phase"
+ ::= { ePDUStatus 4 }
+
+ePDUStatusPhaseEntry OBJECT-TYPE
+ SYNTAX PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to Phase entries"
+ INDEX { ePDUStatusPhaseIndex }
+ ::= { ePDUStatusPhaseTable 1 }
+
+PhaseEntry ::=
+ SEQUENCE {
+ ePDUStatusPhaseIndex INTEGER,
+ ePDUStatusPhaseNumber INTEGER,
+ ePDUStatusPhaseState INTEGER
+ }
+
+ePDUStatusPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the RACK PDU Phase entry."
+ ::= { ePDUStatusPhaseEntry 1 }
+
+ePDUStatusPhaseNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase number."
+ ::= { ePDUStatusPhaseEntry 2 }
+
+ePDUStatusPhaseState OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseLoadNormal (1),
+ phaseLoadLow (2),
+ phaseLoadNearOverload (3),
+ phaseLoadOverload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Phase load state.
+
+ phaseLoadNormal(1) indicates that the Phase is
+ operating properly within the ePDULoadPhaseConfigLowLoadThreshold
+ and ePDULoadPhaseConfigNearOverloadThreshold OID values.
+
+ phaseLoadLow(2) indicates that the Phase load has
+ dropped below the ePDULoadPhaseConfigLowLoadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ phaseLoadNearOverload(3) indicates that the Phase load
+ is greater than or equal to the
+ ePDULoadPhaseConfigNearOverloadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ phaseLoadOverload(4) indicates that the Phase load is
+ greater than or equal to the ePDULoadPhaseConfigOverloadThreshold
+ OID value.
+ An SNMP trap will occur when this state is entered or cleared."
+ ::= { ePDUStatusPhaseEntry 3 }
+
+
+-- Outlet status table
+
+ePDUStatusOutletTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Status Outlet Table"
+ ::= { ePDUStatus 5 }
+
+
+ePDUStatusOutletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU."
+ ::= { ePDUStatus 6 }
+
+ePDUStatusOutletEntry OBJECT-TYPE
+ SYNTAX OutletEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to Outlet entries"
+ INDEX { ePDUStatusOutletIndex }
+ ::= { ePDUStatusOutletTable 1 }
+
+OutletEntry ::=
+ SEQUENCE {
+ ePDUStatusOutletIndex INTEGER,
+ ePDUStatusOutletNumber INTEGER,
+ ePDUStatusOutletState INTEGER
+ }
+
+ePDUStatusOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the RACK PDU Outlet entry."
+ ::= { ePDUStatusOutletEntry 1 }
+
+ePDUStatusOutletNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Outlet number."
+ ::= { ePDUStatusOutletEntry 2 }
+
+ePDUStatusOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletLoadNormal (1),
+ outletLoadLow (2),
+ outletLoadNearOverload (3),
+ outletLoadOverload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Outlet load state.
+
+ outletLoadNormal(1) indicates that the Outlet is
+ operating properly within the ePDUOutletConfigMonitoredLowLoadThreshold
+ and ePDUOutletConfigMonitoredNearOverloadThreshold OID values.
+
+ outletLoadLow(2) indicates that the Outlet load has
+ dropped below the ePDUOutletConfigMonitoredLowLoadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ outletLoadNearOverload(3) indicates that the Outlet load
+ is greater than or equal to the
+ ePDUOutletConfigMonitoredNearOverloadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ outletLoadOverload(4) indicates that the Outlet load is
+ greater than or equal to the ePDUOutletConfigMonitoredOverloadThreshold
+ OID value.
+ An SNMP trap will occur when this state is entered or cleared."
+ ::= { ePDUStatusOutletEntry 3 }
+
+ePDUStatusInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage in 0.1 Volt."
+ ::= { ePDUStatus 7 }
+
+ePDUStatusInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input frequency in 0.1 Hertz."
+ ::= { ePDUStatus 8 }
+
+-- environment Sensor Group
+
+-- the envirIdent group
+
+envirIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the environment sensor.
+ The maximum string size is device dependent."
+ ::= { envirIdent 1 }
+
+envirIdentLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The location of the environment sensor.
+ The maximum string size is device dependent."
+ ::= { envirIdent 2 }
+
+-- the envirTemp group
+
+envirTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The environment temperature expressed in 1/10 Fahrenheit"
+ ::= { envirTemp 1 }
+
+envirTempHighThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature threshold of the environment sensor.
+ The value expressed in Fahrenheit."
+ ::= { envirTemp 2 }
+
+envirTempLowThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature threshold of the environment sensor.
+ The value expressed in Fahrenheit."
+ ::= { envirTemp 3 }
+
+envirTempRateOfChange OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The rate of change of the temperature.
+ The value expressed in Fahrenheit per 5 minute."
+ ::= { envirTemp 4 }
+
+envirTempHysteresis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of degrees beyond the temperature thresholds
+ at which an active temperature alarm will be cleared.
+ This configuration setting applies to all temperature
+ thresholds.
+ Units are displayed in Fahrenheit."
+ ::= { envirTemp 5 }
+
+envirTemperatureCelsius OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The environment temperature expressed in 1/10 Celsius"
+ ::= { envirTemp 6 }
+
+envirTempCelsiusHighThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature threshold of the environment sensor.
+ The value expressed in Celsius."
+ ::= { envirTemp 7 }
+
+envirTempCelsiusLowThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature threshold of the environment sensor.
+ The value expressed in Celsius."
+ ::= { envirTemp 8 }
+
+envirTempCelsiusRateOfChange OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The rate of change of the temperature.
+ The value expressed in Celsius per 5 minute."
+ ::= { envirTemp 9 }
+
+envirTempCelsiusHysteresis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of degrees beyond the temperature thresholds
+ at which an active temperature alarm will be cleared.
+ This configuration setting applies to all temperature
+ thresholds.
+ Units are displayed in Celsius."
+ ::= { envirTemp 10 }
+
+-- the envirHumid group
+
+envirHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The environment relative humidity expressed in persentage."
+ ::= { envirHumid 1 }
+
+envirHumidHighThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high relative humidity threshold of the environment sensor.
+ The value expressed in persentage."
+ ::= { envirHumid 2 }
+
+envirHumidLowThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low relative humidity threshold of the environment sensor.
+ The value expressed in persentage."
+ ::= { envirHumid 3 }
+
+envirHumidRateOfChange OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The rate of change of the relative humidity.
+ The value expressed in persentage per 5 minute."
+ ::= { envirHumid 4 }
+
+envirHumidHysteresis OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of degrees beyond the relative humidity thresholds
+ at which an active relative humidity alarm will be cleared.
+ This configuration setting applies to all relative humidity
+ thresholds.
+ Units are displayed in persentage."
+ ::= { envirHumid 5 }
+
+envirContactTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of the contact in the environment sensor."
+ ::= { envirContact 1 }
+
+envirContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of information of each contact of the environment sensor."
+ ::= { envirContact 2 }
+
+envirContactEntry OBJECT-TYPE
+ SYNTAX ContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This gives access to contact entries"
+ INDEX { envirContactIndex }
+ ::= { envirContactTable 1 }
+
+ContactEntry ::=
+ SEQUENCE {
+ envirContactIndex INTEGER,
+ envirContactName DisplayString,
+ envirContactStatus INTEGER,
+ envirContactNormalState INTEGER
+ }
+
+envirContactIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the contact of the environment sensor."
+ ::= { envirContactEntry 1 }
+
+envirContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting or setting the name of the contact of the environment sensor."
+ ::= { envirContactEntry 2 }
+
+envirContactStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ contactNormal (1),
+ contactAbnormal (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the Contact Status."
+ ::= { envirContactEntry 3 }
+
+envirContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normalOpen (1),
+ normalClose (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set the contact normal state."
+ ::= { envirContactEntry 4 }
+
+-- ats Group
+-- the atsIdent group
+atsIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the ATS.
+ The maximum string size is device dependent."
+ ::= { atsIdent 1 }
+
+atsIdentModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the model name of the Automatic Transfer Switch.
+ This value is set at the factory."
+ ::= { atsIdent 2 }
+
+atsIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Automatic Transfer Switch.
+ This value is set at the factory."
+ ::= { atsIdent 3 }
+
+atsIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the Automatic Transfer Switch
+ firmware revision."
+ ::= { atsIdent 4 }
+
+atsIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the serial number of
+ the Automatic Transfer Switch. This value is set at the factory."
+ ::= { atsIdent 5 }
+
+atsIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. "
+ ::= { atsIdent 6 }
+
+atsIdentDeviceRatingVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifing the Automatic Transfer Switch rating voltage."
+ ::= { atsIdent 7 }
+
+atsIdentDeviceRatingCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This gives the device rating current in Amps"
+ ::= { atsIdent 8 }
+
+atsIdentDeviceOutletNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This gives the outlet number of the device"
+ ::= { atsIdent 9 }
+
+atsIdentAgentModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the model name of the Agent."
+ ::= { atsIdent 10 }
+
+atsIdentAgentHardwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Agent."
+ ::= { atsIdent 11 }
+
+atsIdentAgentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the Agent firmware revision."
+ ::= { atsIdent 12 }
+
+atsIdentAgentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the serial number of the Agent."
+ ::= { atsIdent 13 }
+
+-- the atsStatus group
+-- the atsStatusDevice group in atsStatus group
+atsStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsNeverDiscovered (1),
+ atsCommEstablished (2),
+ atsCommLost (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current communication status
+ between the Automatic Transfer Switch and the Agent. "
+ ::= { atsStatusDevice 1 }
+
+atsStatusSelectedSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceA (1),
+ sourceB (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current source of power. "
+ ::= { atsStatusDevice 2 }
+
+atsStatusRedundancyState OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsRedundancyLost (1),
+ atsFullyRedundant (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current redundancy state of the ATS.
+ atsRedundancyLost(1) indicates that the ATS is unable to
+ switch over to the alternate power source if the current source fails.
+ atsFullyRedundant(2) indicates that the ATS will switch over to
+ the alternate power source if the current source fails."
+ ::= { atsStatusDevice 3 }
+
+atsStatusPhaseSyncStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ inSync (1),
+ outOfSync (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the phase sync."
+ ::= { atsStatusDevice 4 }
+
+atsStatusDevSourceRelayStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceRelayNormal (1),
+ sourceRelayFail (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the source relay."
+ ::= { atsStatusDevice 5 }
+
+atsStatusDevInRelayStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ inputRelayNormal (1),
+ inputRelayFail (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the input relay."
+ ::= { atsStatusDevice 6 }
+
+atsStatusDevOutRelayStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ outputRelayNormal (1),
+ outputRelayFail (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the Output relay."
+ ::= { atsStatusDevice 7 }
+
+atsStatusDevLCDCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ lcdCommNormal (1),
+ lcdCommFail (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the communication status of the LCD."
+ ::= { atsStatusDevice 8 }
+
+atsStatusDevDB9CommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ db9CommNormal (1),
+ db9CommFail (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the communication status of the DB9."
+ ::= { atsStatusDevice 9 }
+
+-- the atsStatusPowerSupplyTable in atsStatusDevice group
+atsStatusPowerSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AtsStatusPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of power supply table entries."
+ ::= { atsStatusDevice 10 }
+
+atsStatusPowerSupplyEntry OBJECT-TYPE
+ SYNTAX AtsStatusPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing power supply information applicable to a
+ particular input."
+
+ INDEX { atsStatusPowerSupplyTableIndex }
+ ::= { atsStatusPowerSupplyTable 1 }
+
+ AtsStatusPowerSupplyEntry ::= SEQUENCE {
+ atsStatusPowerSupplyTableIndex INTEGER,
+ atsStatusPowerSupplyInputSource INTEGER,
+ atsStatusPowerSupply12VStatus INTEGER,
+ atsStatusPowerSupply5VStatus INTEGER,
+ atsStatusPowerSupply3p3VStatus INTEGER
+ }
+
+atsStatusPowerSupplyTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsStatusPowerSupplyEntry 1 }
+
+atsStatusPowerSupplyInputSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceA (1),
+ sourceB (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input source to the power supply."
+ ::= { atsStatusPowerSupplyEntry 2 }
+
+atsStatusPowerSupply12VStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupplyOK (1),
+ powerSupplyFailure (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the power supply A 12V in system."
+ ::= { atsStatusPowerSupplyEntry 3 }
+
+atsStatusPowerSupply5VStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupplyOK (1),
+ powerSupplyFailure (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the power supply A 5V in system."
+ ::= { atsStatusPowerSupplyEntry 4 }
+
+atsStatusPowerSupply3p3VStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupplyOK (1),
+ powerSupplyFailure (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the status of the power supply A 3.3V in system."
+ ::= { atsStatusPowerSupplyEntry 5 }
+
+-- the atsStatusInput group in atsStatus group
+atsStatusInputNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input feeds to this device.
+ This variable indicates the number of rows in the
+ status input table."
+ ::= { atsStatusInput 1 }
+
+-- the atsStatusInputTable in atsStatusInput group
+atsStatusInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AtsStatusInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the value of atsNumInputs."
+ ::= { atsStatusInput 2 }
+
+atsStatusInputEntry OBJECT-TYPE
+ SYNTAX AtsStatusInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input."
+
+ INDEX { atsStatusInputTableIndex }
+ ::= { atsStatusInputTable 1 }
+
+ AtsStatusInputEntry ::= SEQUENCE {
+ atsStatusInputTableIndex INTEGER,
+ atsStatusInputName DisplayString,
+ atsStatusNumInputPhase INTEGER,
+ atsStatusInputVoltageOrientation INTEGER,
+ atsStatusInputVoltage INTEGER,
+ atsStatusInputFrequency INTEGER,
+ atsStatusInputVolState INTEGER,
+ atsStatusInputFreqState INTEGER
+ }
+
+atsStatusInputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsStatusInputEntry 1 }
+
+atsStatusInputName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A name given to a particular input."
+ ::= { atsStatusInputEntry 2 }
+
+atsStatusNumInputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input phases utilized in this device.
+ The sum of all the atsStatusNumInputPhase variable
+ indicates the number of rows in the status input
+ phase table."
+ ::= { atsStatusInputEntry 3 }
+
+atsStatusInputVoltageOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ singlePhase (2),
+ splitPhase (3),
+ threePhasePhaseToNeutral (4),
+ threePhasePhaseToPhase (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage orientation:
+ 1: unknown for this Source
+ 2: singlePhase - phase 1 voltage is between Phase 1
+ and Neutral.
+ 3: splitPhase - phase 1 voltage is between Phase 1 and
+ Neutral; phase 2 voltage is between Phase 2 and Neutral;
+ phase 3 voltage is between Phase 1 and Phase 2.
+ 4: threePhasePhaseToNeutral - phase 1 voltage is between
+ Phase 1 and Neutral; phase 2 voltage is between Phase 2
+ and Neutral; phase 3 voltage is between Phase 3 and
+ Neutral.
+ 5: threePhasePhaseToPhase - phase 1 voltage is between
+ Phase 1 and Phase 2; phase 2 voltage is between Phase 2
+ and Phase 3; phase 3 voltage is between Phase 3 and
+ Phase 1."
+ ::= { atsStatusInputEntry 4 }
+
+atsStatusInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage in 0.1 Volt."
+ ::= { atsStatusInputEntry 5 }
+
+atsStatusInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input frequency in 0.1 Hertz."
+ ::= { atsStatusInputEntry 6 }
+
+atsStatusInputVolState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ overVoltage (2),
+ underVoltage (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage status."
+ ::= { atsStatusInputEntry 7 }
+
+atsStatusInputFreqState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ overFrequency (2),
+ underFrequency (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input frequency status."
+ ::= { atsStatusInputEntry 8 }
+
+-- the atsStatusInputPhaseTable in atsStatusInput group
+atsStatusInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AtsStatusInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the sum of the atsNumInputPhases."
+ ::= { atsStatusInput 3 }
+
+atsStatusInputPhaseEntry OBJECT-TYPE
+ SYNTAX AtsStatusInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input phase."
+
+ INDEX { atsStatusInputPhaseTableIndex, atsStatusInputPhaseIndex }
+ ::= { atsStatusInputPhaseTable 1 }
+
+ AtsStatusInputPhaseEntry ::= SEQUENCE {
+ atsStatusInputPhaseTableIndex INTEGER,
+ atsStatusInputPhaseIndex INTEGER,
+ atsStatusInputPhaseVoltage INTEGER,
+ atsStatusInputPhaseCurrent INTEGER,
+ atsStatusInputPhasePower INTEGER
+ }
+
+atsStatusInputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsStatusInputPhaseEntry 1 }
+
+atsStatusInputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input phase identifier."
+ ::= { atsStatusInputPhaseEntry 2 }
+
+atsStatusInputPhaseVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage in VAC, or -1 if it's unsupported
+ by this Source."
+ ::= { atsStatusInputPhaseEntry 3 }
+
+atsStatusInputPhaseCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input current in amperes, or -1 if it's
+ unsupported by this Source."
+ ::= { atsStatusInputPhaseEntry 4 }
+
+atsStatusInputPhasePower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input power in Watts, or -1 if it's unsupported
+ by this Source."
+ ::= { atsStatusInputPhaseEntry 5 }
+
+-- the atsConfig group
+atsConfigPreferredSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceA (1),
+ sourceB (2),
+ none (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the preferred source of power when both sources are OK."
+ ::= { atsConfig 1 }
+
+atsConfigNominalVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the nominal voltage of the input."
+ ::= { atsConfig 2 }
+
+atsConfigVoltageSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ high (1),
+ medium (2),
+ low (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable defines the sensitivity to changes in voltage:
+ high(1) for best protection, low(3) for frequent small line
+ voltage changes."
+ ::= { atsConfig 3 }
+
+atsConfigTransferVoltageRange OBJECT-TYPE
+ SYNTAX INTEGER {
+ wide (1),
+ medium (2),
+ narrow (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable defines the range of acceptable voltage from a power source.
+ If the voltage measured from the selected input source is not within this
+ range, the Automatic Transfer Switch will switch over (transfer) to the
+ alternate power source."
+ ::= { atsConfig 4 }
+
+atsConfigNarrowRangeValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To configure the Narrow Range value of acceptable voltage
+ from a power source."
+ ::= { atsConfig 5 }
+
+atsConfigMediumRangeValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To configure the Medium Range value of acceptable voltage
+ from a power source."
+ ::= { atsConfig 6 }
+
+atsConfigWideRangeValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To configure the Wide Range value of acceptable voltage
+ from a power source."
+ ::= { atsConfig 7 }
+
+atsConfigFrequencyDeviation OBJECT-TYPE
+ SYNTAX INTEGER (1..3)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To configure the frequency deviation."
+ ::= { atsConfig 8 }
+
+atsConfigDevLCDOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) which LCD turn off automatically
+ after it remains idle for."
+ ::= { atsConfig 9 }
+
+-- the atsControl group
+atsCtrlResetATS OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ rboot (2),
+ reset (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable will cause the Automatic Transfer Switch to
+ reboot or reset relative setting to default value."
+ ::= { atsControl 1 }
+
+atsCtrlClearEventCounts OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ clear (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable will clear all event counts in Automatic Transfer Switch.
+ Returns (-1) if unsupported."
+ ::= { atsControl 2 }
+
+-- the atsLoad group
+-- the atsLoadDevice group in the atsLoad group
+atsLoadDevPhaseTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Phase Table."
+ ::= { atsLoadDevice 1 }
+
+-- the atsLoadDevPhaseTable in atsLoadDevice group
+atsLoadDevPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadDevPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Phase Max Load in the ATS."
+ ::= { atsLoadDevice 2 }
+
+atsLoadDevPhaseEntry OBJECT-TYPE
+ SYNTAX LoadDevPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS Phases Access."
+ INDEX { atsLoadDevPhaseTableIndex}
+ ::= { atsLoadDevPhaseTable 1 }
+
+ LoadDevPhaseEntry ::=
+ SEQUENCE {
+ atsLoadDevPhaseTableIndex INTEGER,
+ atsLoadDevPhase INTEGER,
+ atsLoadDevPhaseMaxLoad INTEGER
+ }
+
+atsLoadDevPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to ATS phase entry."
+ ::= { atsLoadDevPhaseEntry 1 }
+
+atsLoadDevPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
+ phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
+ phases 3 and 1."
+ ::= { atsLoadDevPhaseEntry 2 }
+
+atsLoadDevPhaseMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power that each
+ phase of the ATS can provide. It is represented in Amps."
+ ::= { atsLoadDevPhaseEntry 3 }
+
+atsLoadDevBankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Bank Table."
+ ::= { atsLoadDevice 3 }
+
+-- the atsLoadDevBankTable in atsLoadDevice group
+atsLoadDevBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AtsLoadDevBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Bank Max Load in the ATS."
+ ::= { atsLoadDevice 4 }
+
+atsLoadDevBankEntry OBJECT-TYPE
+ SYNTAX AtsLoadDevBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS Banks Access."
+ INDEX { atsLoadDevBankTableIndex}
+ ::= { atsLoadDevBankTable 1 }
+
+ AtsLoadDevBankEntry ::=
+ SEQUENCE {
+ atsLoadDevBankTableIndex INTEGER,
+ atsLoadDevBankMaxLoad INTEGER
+ }
+
+atsLoadDevBankTableIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ total (1),
+ bank1 (2),
+ bank2 (3),
+ bank3 (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the ATS bank entry."
+ ::= { atsLoadDevBankEntry 1 }
+
+atsLoadDevBankMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each bank of the ATS can provide. It is
+ represented in Amps."
+ ::= { atsLoadDevBankEntry 2 }
+
+-- the atsLoadStatus group in the atsLoad group
+atsLoadStatusPhaseTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Phase Table."
+ ::= { atsLoadStatus 1 }
+
+-- the atsLoadStatusPhaseTable in atsLoadStatus group
+atsLoadStatusPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadStatusPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Phase Load status in the ATS."
+ ::= { atsLoadStatus 2 }
+
+atsLoadStatusPhaseEntry OBJECT-TYPE
+ SYNTAX LoadStatusPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS Phases Access."
+ INDEX { atsLoadStatusPhaseTableIndex}
+ ::= { atsLoadStatusPhaseTable 1 }
+
+ LoadStatusPhaseEntry ::=
+ SEQUENCE {
+ atsLoadStatusPhaseTableIndex INTEGER,
+ atsLoadStatusPhase INTEGER,
+ atsLoadStatusPhaseLoad INTEGER,
+ atsLoadStatusPhaseLoadState INTEGER,
+ atsLoadStatusPhasePower INTEGER
+ }
+
+atsLoadStatusPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to ATS phase entry."
+ ::= { atsLoadStatusPhaseEntry 1 }
+
+atsLoadStatusPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
+ phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
+ phases 3 and 1."
+ ::= { atsLoadStatusPhaseEntry 2 }
+
+atsLoadStatusPhaseLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output current in 0.1 amperes drawn
+ by the load on the ATS"
+ ::= { atsLoadStatusPhaseEntry 3 }
+
+atsLoadStatusPhaseLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ lowLoad (2),
+ nearOverLoad (3),
+ overLoad (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase load state."
+ ::= { atsLoadStatusPhaseEntry 4 }
+
+atsLoadStatusPhasePower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output power in Watts."
+ ::= { atsLoadStatusPhaseEntry 5 }
+
+atsLoadStatusBankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Bank Table."
+ ::= { atsLoadStatus 3 }
+
+-- the atsLoadStatusBankTable in atsLoadStatus group
+atsLoadStatusBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadStatusBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting the Bank Load status in the ATS."
+ ::= { atsLoadStatus 4 }
+
+atsLoadStatusBankEntry OBJECT-TYPE
+ SYNTAX LoadStatusBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS Bank Access."
+ INDEX { atsLoadStatusBankTableIndex}
+ ::= { atsLoadStatusBankTable 1 }
+
+ LoadStatusBankEntry ::=
+ SEQUENCE {
+ atsLoadStatusBankTableIndex INTEGER,
+ atsLoadStatusBankPhase INTEGER,
+ atsLoadStatusBankLoad INTEGER,
+ atsLoadStatusBankLoadState INTEGER,
+ atsLoadStatusBankPower INTEGER,
+ atsLoadStatusBankEnergy INTEGER,
+ atsLoadStatusBankStartTime INTEGER
+ }
+
+atsLoadStatusBankTableIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ total (1),
+ bank1 (2),
+ bank2 (3),
+ bank3 (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to ATS bank entry."
+ ::= { atsLoadStatusBankEntry 1 }
+
+atsLoadStatusBankPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase number."
+ ::= { atsLoadStatusBankEntry 2 }
+
+atsLoadStatusBankLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output current in 0.1 amperes drawn
+ by the load on the ATS"
+ ::= { atsLoadStatusBankEntry 3 }
+
+atsLoadStatusBankLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ lowLoad (2),
+ nearOverLoad (3),
+ overLoad (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the bank load state."
+ ::= { atsLoadStatusBankEntry 4 }
+
+atsLoadStatusBankPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output power in Watts."
+ ::= { atsLoadStatusBankEntry 5 }
+
+atsLoadStatusBankEnergy OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank apparent power measured in 0.1 kilowatt-hours."
+ ::= { atsLoadStatusBankEntry 6 }
+
+atsLoadStatusBankStartTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the date and time of the last energy meter reset"
+ ::= { atsLoadStatusBankEntry 7 }
+
+-- the atsLoadConfig group in the atsLoad group
+atsLoadCfgPhaseTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Phase Table."
+ ::= { atsLoadConfig 1 }
+
+-- the atsLoadCfgPhaseTable in atsLoadConfig group
+atsLoadCfgPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadCfgPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each ATS phase."
+ ::= { atsLoadConfig 2 }
+
+atsLoadCfgPhaseEntry OBJECT-TYPE
+ SYNTAX LoadCfgPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS phase to configure."
+ INDEX { atsLoadCfgPhaseTableIndex}
+ ::= { atsLoadCfgPhaseTable 1 }
+
+ LoadCfgPhaseEntry ::=
+ SEQUENCE {
+ atsLoadCfgPhaseTableIndex INTEGER,
+ atsLoadCfgPhase INTEGER,
+ atsLoadCfgPhaseLowLoad INTEGER,
+ atsLoadCfgPhaseNearOverLoad INTEGER,
+ atsLoadCfgPhaseOverLoad INTEGER,
+ atsLoadCfgPhaseOutletRestriction INTEGER
+ }
+
+atsLoadCfgPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the ATS phase entry."
+ ::= { atsLoadCfgPhaseEntry 1 }
+
+atsLoadCfgPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
+ phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
+ phases 3 and 1."
+ ::= { atsLoadCfgPhaseEntry 2 }
+
+atsLoadCfgPhaseLowLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in Amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 Amps effectively disables this
+ warning."
+ ::= { atsLoadCfgPhaseEntry 3 }
+
+atsLoadCfgPhaseNearOverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value."
+ ::= { atsLoadCfgPhaseEntry 4 }
+
+atsLoadCfgPhaseOverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value."
+ ::= { atsLoadCfgPhaseEntry 5}
+
+atsLoadCfgPhaseOutletRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a ATS phase when an overload
+ condition is possible and additional outlets are requested to be
+ turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding phase to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigOverloadThreshold OID is exceeded."
+ ::= { atsLoadCfgPhaseEntry 6 }
+
+atsLoadCfgBankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Bank Table."
+ ::= { atsLoadConfig 3 }
+
+-- the atsLoadCfgBankTable in atsLoadConfig group
+atsLoadCfgBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadCfgBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each ATS bank."
+ ::= { atsLoadConfig 4 }
+
+atsLoadCfgBankEntry OBJECT-TYPE
+ SYNTAX LoadCfgBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS phase to configure."
+ INDEX { atsLoadCfgBankTableIndex}
+ ::= { atsLoadCfgBankTable 1 }
+
+ LoadCfgBankEntry ::=
+ SEQUENCE {
+ atsLoadCfgBankTableIndex INTEGER,
+ atsLoadCfgBankLowLoad INTEGER,
+ atsLoadCfgBankNearOverLoad INTEGER,
+ atsLoadCfgBankOverLoad INTEGER,
+ atsLoadCfgBankOutletRestriction INTEGER
+ }
+
+atsLoadCfgBankTableIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ total (1),
+ bank1 (2),
+ bank2 (3),
+ bank3 (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the ATS bank entry."
+ ::= { atsLoadCfgBankEntry 1 }
+
+atsLoadCfgBankLowLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in Amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 Amps effectively disables this
+ warning."
+ ::= { atsLoadCfgBankEntry 2 }
+
+atsLoadCfgBankNearOverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value."
+ ::= { atsLoadCfgBankEntry 3 }
+
+atsLoadCfgBankOverLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in Amps. A warning will be issued when the
+ load is greater than or equal to the threshold value."
+ ::= { atsLoadCfgBankEntry 4 }
+
+atsLoadCfgBankOutletRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a ATS phase when an overload
+ condition is possible and additional outlets are requested to be
+ turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding phase to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDULoadConfigOverloadThreshold OID is exceeded."
+ ::= { atsLoadCfgBankEntry 5 }
+
+-- the atsOutlet group
+-- the atsOutletDevice group in the atsOutlet group
+atsOutletDevTotalOutletNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of outlets on the ATS."
+ ::= { atsOutletDevice 1 }
+
+atsOutletDevCtrlOutletNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of controlled outlets on the ATS."
+ ::= { atsOutletDevice 2 }
+
+atsOutletDevColdStartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of delay, in seconds, between when
+ power is provided to the ATS and when the ATS
+ provides basic master power to the outlets.
+
+ Allowed values are:
+
+ -1 - never apply power automatically.
+ 0 - apply power immediately.
+ 1 to 300 - delay up to 300 seconds (5 minutes)."
+ ::= { atsOutletDevice 3 }
+
+atsOutletDevColdStartState OBJECT-TYPE
+ SYNTAX INTEGER {
+ allOn (1),
+ previous (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ATS outlet state after coldstart.
+ Allowed values are:
+ 1 - all outlets on after coldstart.
+ 2 - outlet status same as previous state."
+ ::= { atsOutletDevice 4 }
+
+atsOutletDevLocalCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable (1),
+ disable (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To configure enable or disable outlet local control function."
+ ::= { atsOutletDevice 5 }
+
+atsOutletDevCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandAll (1),
+ immediateAllOn (2),
+ immediateAllOff (3),
+ immediateAllReboot (4),
+ delayedAllOn (5),
+ delayedAllOff (6),
+ delayedAllReboot (7),
+ cancelAllPendingCommands (8)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOn (2) will turn all outlets
+ on immediately.
+
+ Setting this OID to immediateAllOff (3) will turn all outlets
+ off immediately.
+
+ Setting this OID to immediateAllReboot (4) will reboot all outlets
+ immediately.
+
+ Setting this OID to delayedAllOn (5) will turn all outlets on as
+ defined by each outlet's atsOutletCfgPowerOnTime OID value.
+
+ Setting this OID to delayedAllOff (6) will turn all outlets
+ off as defined by each outlet's atsOutletCfgPowerOffTime OID value.
+
+ Setting this OID to delayedAllReboot (7) will cause a
+ delayedAllOff command to be performed. Once all outlets are off,
+ the Switched Rack ATS will then delay the largest
+ atsOutletCfgRebootDuration OID time, and then perform a
+ delayedAllOn command.
+
+ Setting this OID to cancelAllPendingCommands (8) will cause all pending
+ commands on the Switched Rack ATS to be canceled.
+
+ Getting this OID will return the noCommandAll (1) value."
+ ::= { atsOutletDevice 6 }
+
+atsOutletStatusTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the outlet status table."
+ ::= { atsOutlet 2 }
+
+-- the atsOutletStatusTable in atsOutlet group
+atsOutletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of individual outlets."
+ ::= { atsOutlet 3 }
+
+atsOutletStatusEntry OBJECT-TYPE
+ SYNTAX OutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to gather status from."
+ INDEX { atsOutletStatusTableIndex}
+ ::= { atsOutletStatusTable 1 }
+
+ OutletStatusEntry ::=
+ SEQUENCE {
+ atsOutletStatusTableIndex INTEGER,
+ atsOutletStatusOutletName DisplayString,
+ atsOutletStatusOutletState INTEGER,
+ atsOutletStatusOutletCmdPending INTEGER,
+ atsOutletStatusOutletPhase INTEGER,
+ atsOutletStatusOutletBank INTEGER
+ }
+
+atsOutletStatusTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..19)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { atsOutletStatusEntry 1 }
+
+atsOutletStatusOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ This OID is provided for informational purposes only."
+ ::= { atsOutletStatusEntry 2 }
+
+atsOutletStatusOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusOn (1),
+ outletStatusOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletStatusOn (1) value will be returned.
+ If the outlet is off, the outletStatusOff (2) value will be
+ returned."
+ ::= { atsOutletStatusEntry 3 }
+
+atsOutletStatusOutletCmdPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusCommandPending (1),
+ outletStatusNoCommandPending (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet. If a command is pending on the
+ outlet, the outletStatusCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet, the outletStatusNoCommandPending (2)
+ will be returned."
+ ::= { atsOutletStatusEntry 4 }
+
+atsOutletStatusOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { atsOutletStatusEntry 5 }
+
+atsOutletStatusOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { atsOutletStatusEntry 6 }
+
+atsOutletCtrlTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the outlet control table."
+ ::= { atsOutlet 4 }
+
+-- the atsOutletCtrlTable in atsOutlet group
+atsOutletCtrlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletCtrlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the individual outlets."
+ ::= { atsOutlet 5 }
+
+atsOutletCtrlEntry OBJECT-TYPE
+ SYNTAX OutletCtrlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to control."
+ INDEX { atsOutletCtrlTableIndex}
+ ::= { atsOutletCtrlTable 1 }
+
+ OutletCtrlEntry ::=
+ SEQUENCE {
+ atsOutletCtrlTableIndex INTEGER,
+ atsOutletCtrlOutletName DisplayString,
+ atsOutletCtrlCommand INTEGER
+ }
+
+atsOutletCtrlTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..19)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { atsOutletCtrlEntry 1 }
+
+atsOutletCtrlOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ An error will be returned if the set request exceeds the max size.
+ This OID is provided for informational purposes only."
+ ::= { atsOutletCtrlEntry 2 }
+
+atsOutletCtrlCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ immediateOn (2),
+ immediateOff (3),
+ immediateReboot (4),
+ delayedOn (5),
+ delayedOff (6),
+ delayedReboot (7),
+ cancelPendingCommand (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOn (2) value will be returned.
+ If the outlet is off, the immediateOff (2) value will be
+ returned.
+
+ Setting this variable to immediateOn (2) will immediately turn
+ the outlet on.
+
+ Setting this variable to immediateOff (3) will immediately turn
+ the outlet off.
+
+ Setting this variable to immediateReboot (4) will immediately
+ reboot the outlet.
+
+ Setting this variable to delayedOn (5) will turn the outlet on
+ after the ePDUOutletConfigPowerOnTime OID time has elapsed.
+
+ Setting this variable to delayedOff (6) will turn the outlet off
+ after the ePDUOutletConfigPowerOffTime OID time has elapsed.
+
+ Setting this variable to delayedReboot (7) will cause the
+ ATS to perform a delayedOff command, wait the atsOutletCfgRebootDuration
+ OID time, and then perform a delayedOn command.
+
+ Setting this variable to cancelPendingCommand (8) will cause any
+ pending command to this outlet to be canceled."
+ ::= { atsOutletCtrlEntry 3 }
+
+atsOutletCfgTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the outlet config table."
+ ::= { atsOutlet 6 }
+
+-- the atsOutletCfgTable in atsOutlet group
+atsOutletCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AtsOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets."
+ ::= { atsOutlet 7 }
+
+atsOutletCfgEntry OBJECT-TYPE
+ SYNTAX AtsOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to configure."
+ INDEX { atsOutletCfgTableIndex}
+ ::= { atsOutletCfgTable 1 }
+
+ AtsOutletConfigEntry ::=
+ SEQUENCE {
+ atsOutletCfgTableIndex INTEGER,
+ atsOutletCfgOutletName DisplayString,
+ atsOutletCfgPowerOnTime INTEGER,
+ atsOutletCfgPowerOffTime INTEGER,
+ atsOutletCfgRebootDuration INTEGER
+ }
+
+atsOutletCfgTableIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..19)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { atsOutletCfgEntry 1 }
+
+atsOutletCfgOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum string size is device dependent.
+ An error will be returned if the set request exceeds the max size."
+ ::= { atsOutletCfgEntry 2 }
+
+atsOutletCfgPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on at coldstart or when a command that requires
+ a turn-on delay is issued.
+
+ Allowed values are:
+ -1 - never power on.
+ 0 - power on immediately.
+ 1 to 7200 - power on up to 7200 seconds after being commanded."
+ ::= { atsOutletCfgEntry 3 }
+
+atsOutletCfgPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off when a command that requires
+ a turn-off delay is issued.
+
+ Allowed values are:
+
+ -1 - never power off.
+ 0 - power off immediately.
+ 1 to 7200 - power off up to 7200 seconds after being commanded."
+ ::= { atsOutletCfgEntry 4 }
+
+atsOutletCfgRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed range is any value between 5 and 60 seconds (1 minute)."
+ ::= { atsOutletCfgEntry 5 }
+
+-- ePDU2 Group
+-- Daisy Chain ePDU OID
+ePDU2Role OBJECT-TYPE
+ SYNTAX INTEGER {
+ standalone(1),
+ host(2),
+ slave(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the role the PDU played on Daisy Chain Group.
+ The PDU as a Host can access whole ePDU2 content, and the PDU be standalong
+ or a Slave can access itself instead."
+ ::= { ePDU2 1 }
+
+-- ePDU2Ident
+ePDU2IdentTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "PDU as a Host response total PDU ident number on daisy chain.
+ PDU as a Slave can only response 1."
+ ::= { ePDU2Ident 1 }
+
+ePDU2IdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2IdentEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU identification information."
+ ::= { ePDU2Ident 2 }
+
+ePDU2IdentEntry OBJECT-TYPE
+ SYNTAX EPDU2IdentEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Identification data from Rack PDU being queried."
+ INDEX { ePDU2IdentIndex }
+ ::= { ePDU2IdentTable 1 }
+
+EPDU2IdentEntryStruct ::=
+ SEQUENCE {
+ ePDU2IdentIndex INTEGER,
+ ePDU2IdentModuleIndex INTEGER,
+ ePDU2IdentName DisplayString,
+ ePDU2IdentLocation DisplayString,
+ ePDU2IdentContact DisplayString,
+ ePDU2IdentHardwareRev DisplayString,
+ ePDU2IdentFirmwareRev DisplayString,
+ ePDU2IdentDateOfManufacture DisplayString,
+ ePDU2IdentModelName DisplayString,
+ ePDU2IdentSerialNumber DisplayString,
+ ePDU2IdentIndicator INTEGER
+ }
+
+ePDU2IdentIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU identification table entry."
+ ::= { ePDU2IdentEntry 1 }
+
+ePDU2IdentModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU identification table entry numeric ID."
+ ::= { ePDU2IdentEntry 2 }
+
+ePDU2IdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the name of the Rack PDU."
+ ::= { ePDU2IdentEntry 3 }
+
+ePDU2IdentLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the location of the Rack PDU."
+ ::= { ePDU2IdentEntry 4 }
+
+ePDU2IdentContact OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the person to contact of the Rack PDU."
+ ::= { ePDU2IdentEntry 5 }
+
+ePDU2IdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU hardware version."
+ ::= { ePDU2IdentEntry 6 }
+
+ePDU2IdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU firmware version."
+ ::= { ePDU2IdentEntry 7 }
+
+ePDU2IdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the Rack PDU was manufactured in mm/dd/yyyy format."
+ ::= { ePDU2IdentEntry 8 }
+
+ePDU2IdentModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU model number."
+ ::= { ePDU2IdentEntry 9 }
+
+ePDU2IdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU serial number."
+ ::= { ePDU2IdentEntry 10 }
+
+ePDU2IdentIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "PDU will perform a panel indicator test when the variable
+ is set to testIndicators(2).
+
+ It is no effective to set this value to noTestIndicators(1)."
+ ::= { ePDU2IdentEntry 11 }
+
+-- ePDU2Device
+ePDU2DeviceTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A Host Rack PDU response total number of Rack PDUs on daisy chain.
+ Rack PDU as a Slave can only response 1."
+ ::= { ePDU2Device 1 }
+
+-- Device Config Table
+ePDU2DeviceConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2DeviceConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU configuration data."
+ ::= { ePDU2Device 2 }
+
+ePDU2DeviceConfigEntry OBJECT-TYPE
+ SYNTAX EPDU2DeviceConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Configuration data from Rack PDU being queried."
+ INDEX { ePDU2DeviceConfigIndex }
+ ::= { ePDU2DeviceConfigTable 1 }
+
+EPDU2DeviceConfigEntryStruct ::=
+ SEQUENCE {
+ ePDU2DeviceConfigIndex INTEGER,
+ ePDU2DeviceConfigModuleIndex INTEGER,
+ ePDU2DeviceConfigName DisplayString,
+ ePDU2DeviceConfigLocation DisplayString,
+ ePDU2DeviceConfigContact DisplayString,
+ ePDU2DeviceConfigDisplayOrientation INTEGER,
+ ePDU2DeviceConfigColdstartDelay INTEGER,
+ ePDU2DeviceConfigCurrentLowLoadThreshold INTEGER,
+ ePDU2DeviceConfigCurrentNearOverloadThreshold INTEGER,
+ ePDU2DeviceConfigCurrentOverloadThreshold INTEGER,
+ ePDU2DeviceConfigPeakLoadReset INTEGER,
+ ePDU2DeviceConfigEnergyReset INTEGER,
+ ePDU2DeviceConfigPowerLowLoadThreshold INTEGER,
+ ePDU2DeviceConfigPowerNearOverloadThreshold INTEGER,
+ ePDU2DeviceConfigPowerOverloadThreshold INTEGER
+ }
+
+ePDU2DeviceConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU table entry."
+ ::= { ePDU2DeviceConfigEntry 1 }
+
+ePDU2DeviceConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= { ePDU2DeviceConfigEntry 2 }
+
+ePDU2DeviceConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the name of Rack PDU."
+ ::= { ePDU2DeviceConfigEntry 3 }
+
+ePDU2DeviceConfigLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the location of the Rack PDU."
+ ::= { ePDU2DeviceConfigEntry 4 }
+
+ePDU2DeviceConfigContact OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the person to contact of the Rack PDU."
+ ::= { ePDU2DeviceConfigEntry 5 }
+
+ePDU2DeviceConfigDisplayOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ displayNormal (1),
+ displayReverse (2),
+ displayRotate90 (3),
+ displayRotate270 (4),
+ displayAuto (5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the intended physical orientation of the Seven-Segment Display.
+
+ displayNormal(1) indicates Normal.
+ displayReverse(2)indicates Upside-Down.
+ displayRotate90(3) indicates rotate 90 degree.
+ displayRotate270(4) indicates rotate 270 degree.
+ displayAuto(5) indicates auto-detect and rotate."
+ ::= { ePDU2DeviceConfigEntry 6 }
+
+ePDU2DeviceConfigColdstartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of delay, measured in seconds, between
+ when power is provided to the Rack PDU and when
+ the Rack PDU provides basic master power to the
+ outlets.
+
+ Allowed values are:
+ -1 - never apply power automatically.
+ 0 - apply power immediately.
+ 1 to 300 - delay up to 300 seconds (5 minutes)."
+ ::= { ePDU2DeviceConfigEntry 7 }
+
+ePDU2DeviceConfigCurrentLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined low current draw alarm threshold, measured in Amps."
+ ::= { ePDU2DeviceConfigEntry 8 }
+
+ePDU2DeviceConfigCurrentNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined near overload current threshold, measured in Amps."
+ ::= { ePDU2DeviceConfigEntry 9 }
+
+ePDU2DeviceConfigCurrentOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined current overload threshold, measured in Amps."
+ ::= { ePDU2DeviceConfigEntry 10 }
+
+ePDU2DeviceConfigPeakLoadReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation(1),
+ resetAll(2),
+ resetDevice(3),
+ resetOutlets(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to resetAll (2) will cause the existing peak current value
+ of Rack PDU and its outlets to be replaced by the current load current value.
+ Setting this OID to resetDevice (3) to reset the Rack PDU only.
+ Setting this OID to resetOutlets (4) to reset the PDU outlets only.
+
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= { ePDU2DeviceConfigEntry 11 }
+
+ePDU2DeviceConfigEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation(1),
+ resetAll(2),
+ resetDevice(3),
+ resetOutlets(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to resetAll (2) will cause the device energy meter value
+ to be reset to zero.
+ Setting this OID to resetDevice (3) to reset the Rack PDU only.
+ Setting this OID to resetOutlets (4) to reset the PDU outlets only.
+
+ Getting this OID in models that support this feature will do nothing
+ and return the noOperation(1) value."
+ ::= { ePDU2DeviceConfigEntry 12 }
+
+ePDU2DeviceConfigPowerLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined low power draw alarm threshold, measured in Watts."
+ ::= { ePDU2DeviceConfigEntry 13 }
+
+ePDU2DeviceConfigPowerNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined near overload power threshold, measured in Watts."
+ ::= { ePDU2DeviceConfigEntry 14 }
+
+ePDU2DeviceConfigPowerOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined power overload threshold, measured in Watts."
+ ::= { ePDU2DeviceConfigEntry 15 }
+
+-- Device Info Table
+ePDU2DeviceInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2DeviceInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU information."
+ ::= { ePDU2Device 3 }
+
+ePDU2DeviceInfoEntry OBJECT-TYPE
+ SYNTAX EPDU2DeviceInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information of the Rack PDU being queried."
+ INDEX {ePDU2DeviceInfoIndex}
+ ::= { ePDU2DeviceInfoTable 1 }
+
+EPDU2DeviceInfoEntryStruct ::=
+ SEQUENCE {
+ ePDU2DeviceInfoIndex INTEGER,
+ ePDU2DeviceInfoModuleIndex INTEGER,
+ ePDU2DeviceInfoName DisplayString,
+ ePDU2DeviceInfoRating INTEGER,
+ ePDU2DeviceInfoNumOutlets INTEGER,
+ ePDU2DeviceInfoSwitchedOutlets INTEGER,
+ ePDU2DeviceInfoMeteredOutlets INTEGER,
+ ePDU2DeviceInfoNumPhases INTEGER,
+ ePDU2DeviceInfoNumBreakers INTEGER,
+ ePDU2DeviceInfoBreakerRating INTEGER,
+ ePDU2DeviceInfoOrientation INTEGER,
+ ePDU2DeviceInfoOutletLayout INTEGER
+ }
+
+ePDU2DeviceInfoIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU Information table entry."
+ ::= {ePDU2DeviceInfoEntry 1}
+
+ePDU2DeviceInfoModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2DeviceInfoEntry 2}
+
+ePDU2DeviceInfoName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the name of the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 3}
+
+ePDU2DeviceInfoRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The electrical rating of the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 4}
+
+ePDU2DeviceInfoNumOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlets on the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 5}
+
+ePDU2DeviceInfoSwitchedOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of switched outlets on the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 6}
+
+ePDU2DeviceInfoMeteredOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of metered outlets on the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 7}
+
+ePDU2DeviceInfoNumPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of phases present in the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 8}
+
+ePDU2DeviceInfoNumBreakers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of metered banks present in the Rack PDU."
+ ::= {ePDU2DeviceInfoEntry 9}
+
+ePDU2DeviceInfoBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum current rating, measured in Amps, for the Rack PDU.
+ Getting this OID will return rating of the circuit breakers on
+ the device if it has any."
+ ::= {ePDU2DeviceInfoEntry 10}
+
+ePDU2DeviceInfoOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ orientHorizontal (1),
+ orientVertical (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rack PDU orientation."
+ ::= {ePDU2DeviceInfoEntry 11}
+
+ePDU2DeviceInfoOutletLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhaseToNeutral (1),
+ seqPhaseToPhase (2),
+ seqPhToNeu21PhToPh (3),
+ seqPhToPhGrouped (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return outlet layout for the device.
+
+ SeqPhaseToNeutral(1) indicates outlet layout as follows:
+ 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
+
+ SeqPhaseToPhase(2) indicates outlet layout as follows:
+ 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
+
+ SeqPhToNeu21PhToPh(3) indicates outlet layout as follows:
+ 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
+
+ SeqPhToPhGrouped(4) indicates outlet layout as follows:
+ Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2)."
+ ::= {ePDU2DeviceInfoEntry 12}
+
+-- Device Status Table
+ePDU2DeviceStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2DeviceStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU current status."
+ ::= { ePDU2Device 4 }
+
+ePDU2DeviceStatusEntry OBJECT-TYPE
+ SYNTAX EPDU2DeviceStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Status data from the Rack PDU being queried."
+ INDEX {ePDU2DeviceStatusIndex}
+ ::= { ePDU2DeviceStatusTable 1 }
+
+EPDU2DeviceStatusEntryStruct ::=
+ SEQUENCE {
+ ePDU2DeviceStatusIndex INTEGER,
+ ePDU2DeviceStatusModuleIndex INTEGER,
+ ePDU2DeviceStatusName DisplayString,
+ ePDU2DeviceStatusLoadState INTEGER,
+ ePDU2DeviceStatusCurrentLoad Gauge,
+ ePDU2DeviceStatusCurrentPeakLoad Gauge,
+ ePDU2DeviceStatusPeakLoadTimestamp DisplayString,
+ ePDU2DeviceStatusPeakLoadStartTime DisplayString,
+ ePDU2DeviceStatusEnergy Gauge,
+ ePDU2DeviceStatusEnergyStartTime DisplayString,
+ ePDU2DeviceStatusCommandPending INTEGER,
+ ePDU2DeviceStatusPowerSupplyAlarm INTEGER,
+ ePDU2DeviceStatusPowerSupply1Status INTEGER,
+ ePDU2DeviceStatusPowerSupply2Status INTEGER,
+ ePDU2DeviceStatusApparentPower Gauge,
+ ePDU2DeviceStatusPowerFactor Gauge,
+ ePDU2DeviceStatusRoleType INTEGER,
+ ePDU2DeviceStatusPowerLoad Gauge,
+ ePDU2DeviceStatusPowerPeakLoad Gauge
+ }
+
+ePDU2DeviceStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU status table entry."
+ ::= {ePDU2DeviceStatusEntry 1}
+
+ePDU2DeviceStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID"
+ ::= {ePDU2DeviceStatusEntry 2}
+
+ePDU2DeviceStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the name of the Rack PDU."
+ ::= {ePDU2DeviceStatusEntry 3}
+
+ePDU2DeviceStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLoadAlarm (1),
+ underCurrentAlarm (2),
+ nearOverCurrentAlarm (3),
+ overCurrentAlarm (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the present load status of the Rack PDU."
+ ::= {ePDU2DeviceStatusEntry 4}
+
+ePDU2DeviceStatusCurrentLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power consumption of the Rack PDU load in tenths of Amps."
+ ::= {ePDU2DeviceStatusEntry 5}
+
+ePDU2DeviceStatusCurrentPeakLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak power consumption of the Rack PDU load in tenths of Amps."
+ ::= {ePDU2DeviceStatusEntry 6}
+
+ePDU2DeviceStatusPeakLoadTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time that peak load occurred."
+ ::= {ePDU2DeviceStatusEntry 7}
+
+ePDU2DeviceStatusPeakLoadStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last device peak load reset."
+ ::= {ePDU2DeviceStatusEntry 8}
+
+ePDU2DeviceStatusEnergy OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user resettable energy meter measuring Rack PDU load
+ energy consumption in tenths of kilowatt-hours."
+ ::= {ePDU2DeviceStatusEntry 9}
+
+ePDU2DeviceStatusEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last device energy
+ meter reset."
+ ::= {ePDU2DeviceStatusEntry 10}
+
+ePDU2DeviceStatusCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ commandPending (1),
+ noCommandPending (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the device
+ is processing a pending command."
+ ::= {ePDU2DeviceStatusEntry 11}
+
+ePDU2DeviceStatusPowerSupplyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates a power supply alarm is active when value
+ equals alarm (2)."
+ ::= {ePDU2DeviceStatusEntry 12}
+
+ePDU2DeviceStatusPowerSupply1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not an alarm is active in Power
+ Supply 1."
+ ::= {ePDU2DeviceStatusEntry 13}
+
+ePDU2DeviceStatusPowerSupply2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not an alarm is active in Power
+ Supply 2."
+ ::= {ePDU2DeviceStatusEntry 14}
+
+ePDU2DeviceStatusApparentPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The apparent power consumption of the Rack PDU
+ load in VoltAmps (VA)."
+ ::= {ePDU2DeviceStatusEntry 15}
+
+ePDU2DeviceStatusPowerFactor OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power factor of the Rack PDU load in hundredths."
+ ::= {ePDU2DeviceStatusEntry 16}
+
+ePDU2DeviceStatusRoleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ standalone (1),
+ host (2) ,
+ slave (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the role the PDU played on Daisy Chain Group.
+ The PDU as a Host can access whole ePDU2 content, and the PDU be standalong
+ or a Slave can access itself instead."
+ ::= {ePDU2DeviceStatusEntry 17}
+
+ePDU2DeviceStatusPowerLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power consumption of the Rack PDU load in Watts."
+ ::= {ePDU2DeviceStatusEntry 18}
+
+ePDU2DeviceStatusPowerPeakLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak power consumption of the Rack PDU load in Watts."
+ ::= {ePDU2DeviceStatusEntry 19}
+
+-- Device Control Table
+ePDU2DeviceControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2DeviceControlEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU control data."
+ ::= { ePDU2Device 5 }
+
+ePDU2DeviceControlEntry OBJECT-TYPE
+ SYNTAX EPDU2DeviceControlEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Control data from Rack PDU being queried."
+ INDEX {ePDU2DeviceControlIndex}
+ ::= {ePDU2DeviceControlTable 1}
+
+EPDU2DeviceControlEntryStruct ::=
+ SEQUENCE {
+ ePDU2DeviceControlIndex INTEGER,
+ ePDU2DeviceControlModuleIndex INTEGER,
+ ePDU2DeviceControlName DisplayString,
+ ePDU2DeviceControlCommand INTEGER
+ }
+
+ePDU2DeviceControlIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU control table entry."
+ ::= {ePDU2DeviceControlEntry 1}
+
+ePDU2DeviceControlModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2DeviceControlEntry 2}
+
+ePDU2DeviceControlName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A user-defined string identifying the name of the Rack PDU."
+ ::= {ePDU2DeviceControlEntry 3}
+
+ePDU2DeviceControlCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateAllOn (1),
+ immediateAllOff (2),
+ immediateAllReboot (3),
+ delayedAllOn (4),
+ delayedAllOff (5),
+ delayedAllReboot (6),
+ cancelAllPendingCommand (7),
+ noCommand (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOn (1) will turn all outlets on immediately.
+
+ Setting this OID to immediateAllOff (2) will turn all outlets off immediately.
+
+ Setting this OID to immediateAllReboot (3) will cause an immediateAllOff command
+ to be performed. Once all outlets are off, the Switched Rack PDU will then delay
+ the ePDU2OutletSwitchedConfigRebootDuration OID time, and then perform an
+ immediateAllOn command.
+
+ Setting this OID to delayedAllOn (4) will turn all outlets on as defined by
+ each outlet's ePDU2OutletSwitchedConfigPowerOnTime OID value.
+
+ Setting this OID to delayedAllOff (5) will turn all outlets off as defined by
+ each outlet's ePDU2OutletSwitchedConfigPowerOffTime OID value.
+
+ Setting this OID to delayedAllReboot (6) will cause a delayedAllOff command
+ to be performed. Once all outlets are off, the Switched Rack PDU will then
+ delay the largest ePDU2OutletSwitchedConfigRebootDuration OID time, and
+ then perform a delayedAllOn command.
+
+ Setting this OID to cancelAllPendingCommand (7) will cause all pending
+ commands on the Switched Rack PDU to be cancelled.
+
+ Setting this OID to noCommand (8) will have no effect.
+
+ Getting this OID will return the noCommand (8) value."
+ ::= {ePDU2DeviceControlEntry 4}
+
+-- ePDU2Phase
+ePDU2PhaseTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A Host Rack PDU response total phase number of Rack PDUs on daisy chain.
+ Rack PDU as a Slave can only response itself number of phase."
+ ::= {ePDU2Phase 1}
+
+ePDU2PhaseConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2PhaseConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU phase configuration data."
+ ::= {ePDU2Phase 2}
+
+ePDU2PhaseConfigEntry OBJECT-TYPE
+ SYNTAX EPDU2PhaseConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Configuration data from currently queried
+ Rack PDU phase."
+ INDEX {ePDU2PhaseConfigIndex}
+ ::= {ePDU2PhaseConfigTable 1}
+
+EPDU2PhaseConfigEntryStruct ::=
+ SEQUENCE {
+ ePDU2PhaseConfigIndex INTEGER,
+ ePDU2PhaseConfigModuleIndex INTEGER,
+ ePDU2PhaseConfigNumber INTEGER,
+ ePDU2PhaseConfigOverloadRestriction INTEGER,
+ ePDU2PhaseConfigLowLoadThreshold INTEGER,
+ ePDU2PhaseConfigNearOverloadThreshold INTEGER,
+ ePDU2PhaseConfigOverloadThreshold INTEGER,
+ ePDU2PhaseConfigPhasePeakLoadReset INTEGER
+ }
+
+ePDU2PhaseConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..12)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase configuration
+ table entry."
+ ::= {ePDU2PhaseConfigEntry 1}
+
+ePDU2PhaseConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2PhaseConfigEntry 2}
+
+ePDU2PhaseConfigNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric phase ID."
+ ::= {ePDU2PhaseConfigEntry 3}
+
+ePDU2PhaseConfigOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ notSupported (-1),
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ phase when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding phase to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDU2PhaseConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding phase to turn on if the
+ ePDU2PhaseConfigOverloadThreshold OID is exceeded.
+
+ Models that do not support this feature will respond to this OID
+ with a value of notSupported (-1). Attempts to set this OID
+ in these models will fail."
+ ::= {ePDU2PhaseConfigEntry 4}
+
+ePDU2PhaseConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined low load phase current threshold in Amps."
+ ::= {ePDU2PhaseConfigEntry 5}
+
+ePDU2PhaseConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined near phase overload current warning
+ threshold in Amps."
+ ::= {ePDU2PhaseConfigEntry 6}
+
+ePDU2PhaseConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined phase overload current threshold
+ in Amps"
+ ::= {ePDU2PhaseConfigEntry 7}
+
+ePDU2PhaseConfigPhasePeakLoadReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the existing peak current value
+ to be replaced by the present load current value.
+
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= {ePDU2PhaseConfigEntry 8}
+
+ePDU2PhaseInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2PhaseInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU phase information."
+ ::= {ePDU2Phase 3}
+
+ePDU2PhaseInfoEntry OBJECT-TYPE
+ SYNTAX EPDU2PhaseInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information data from currently queried Rack PDU phase."
+ INDEX {ePDU2PhaseInfoIndex}
+ ::= {ePDU2PhaseInfoTable 1}
+
+EPDU2PhaseInfoEntryStruct ::=
+ SEQUENCE {
+ ePDU2PhaseInfoIndex INTEGER,
+ ePDU2PhaseInfoModuleIndex INTEGER,
+ ePDU2PhaseInfoNumber INTEGER
+ }
+
+ePDU2PhaseInfoIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..12)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase properties table entry."
+ ::= {ePDU2PhaseInfoEntry 1}
+
+ePDU2PhaseInfoModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2PhaseInfoEntry 2}
+
+ePDU2PhaseInfoNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric phase ID."
+ ::= {ePDU2PhaseInfoEntry 3}
+
+ePDU2PhaseStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2PhaseStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU phase status data"
+ ::= {ePDU2Phase 4}
+
+ePDU2PhaseStatusEntry OBJECT-TYPE
+ SYNTAX EPDU2PhaseStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Status data from currently queried Rack PDU phase"
+ INDEX {ePDU2PhaseStatusIndex}
+ ::= {ePDU2PhaseStatusTable 1}
+
+EPDU2PhaseStatusEntryStruct ::=
+ SEQUENCE {
+ ePDU2PhaseStatusIndex INTEGER,
+ ePDU2PhaseStatusModuleIndex INTEGER,
+ ePDU2PhaseStatusNumber INTEGER,
+ ePDU2PhaseStatusLoadState INTEGER,
+ ePDU2PhaseStatusLoad Gauge,
+ ePDU2PhaseStatusVoltage Gauge,
+ ePDU2PhaseStatusPower Gauge,
+ ePDU2PhaseStatusApparentPower Gauge,
+ ePDU2PhaseStatusPowerFactor Gauge,
+ ePDU2PhaseStatusPeakLoad Gauge,
+ ePDU2PhaseStatusPeakLoadTimestamp DisplayString,
+ ePDU2PhaseStatusPeakLoadStartTime DisplayString,
+ ePDU2PhaseStatusLineToLineVoltage Gauge
+ }
+
+ePDU2PhaseStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..13)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase status table entry."
+ ::= {ePDU2PhaseStatusEntry 1}
+
+ePDU2PhaseStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2PhaseStatusEntry 2}
+
+ePDU2PhaseStatusNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric phase ID."
+ ::= {ePDU2PhaseStatusEntry 3}
+
+ePDU2PhaseStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ lowLoad (2),
+ nearOverload (3),
+ overload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the present load status of the Rack
+ PDU phase being queried."
+ ::= {ePDU2PhaseStatusEntry 4}
+
+ePDU2PhaseStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current draw, in tenths of Amps, of the load
+ on the Rack PDU phase being queried."
+ ::= {ePDU2PhaseStatusEntry 5}
+
+ePDU2PhaseStatusVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Voltage, in tenths of Volts, of the Rack
+ PDU phase being queried"
+ ::= {ePDU2PhaseStatusEntry 6}
+
+ePDU2PhaseStatusPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the load power, in watts,
+ consumed on the Rack PDU phase being queried"
+ ::= {ePDU2PhaseStatusEntry 7}
+
+ePDU2PhaseStatusApparentPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the load apparent power, in VoltAmps (VA),
+ consumed on the Rack PDU phase being queried"
+ ::= {ePDU2PhaseStatusEntry 8}
+
+ePDU2PhaseStatusPowerFactor OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the load power factor, in hundredths,
+ of the Rack PDU phase being queried"
+ ::= {ePDU2PhaseStatusEntry 9}
+
+ePDU2PhaseStatusPeakLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak current of the Rack PDU phase load in tenths of Amps"
+ ::= {ePDU2PhaseStatusEntry 10}
+
+ePDU2PhaseStatusPeakLoadTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time the phase peak current occurred."
+ ::= {ePDU2PhaseStatusEntry 11}
+
+ePDU2PhaseStatusPeakLoadStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last phase peak current reset."
+ ::= {ePDU2PhaseStatusEntry 12}
+
+ePDU2PhaseStatusLineToLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Line to Line Voltage, in tenths of Volts, of the Rack
+ PDU phase being queried"
+ ::= {ePDU2PhaseStatusEntry 13}
+
+-- ePDU2Bank
+ePDU2BankTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A Host Rack PDU response total bank number of Rack PDUs on daisy chain.
+ Rack PDU as a Slave can only response itself number of bank."
+ ::= {ePDU2Bank 1}
+
+ePDU2BankConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2BankConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU bank configuration data."
+ ::= {ePDU2Bank 2}
+
+ePDU2BankConfigEntry OBJECT-TYPE
+ SYNTAX EPDU2BankConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Configuration data from currently queried
+ Rack PDU bank."
+ INDEX {ePDU2BankConfigIndex}
+ ::= {ePDU2BankConfigTable 1}
+
+EPDU2BankConfigEntryStruct ::=
+ SEQUENCE {
+ ePDU2BankConfigIndex INTEGER,
+ ePDU2BankConfigModuleIndex INTEGER,
+ ePDU2BankConfigNumber INTEGER,
+ ePDU2BankConfigOverloadRestriction INTEGER,
+ ePDU2BankConfigLowLoadThreshold INTEGER,
+ ePDU2BankConfigNearOverloadThreshold INTEGER,
+ ePDU2BankConfigOverloadThreshold INTEGER,
+ ePDU2BankConfigPeakLoadReset INTEGER
+ }
+
+ePDU2BankConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..12)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank configuration
+ table entry."
+ ::= {ePDU2BankConfigEntry 1}
+
+ePDU2BankConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2BankConfigEntry 2}
+
+ePDU2BankConfigNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric bank ID."
+ ::= {ePDU2BankConfigEntry 3}
+
+ePDU2BankConfigOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ bank when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding bank to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding bank to turn on if the
+ ePDU2BankConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding bank to turn on if the
+ ePDU2BankConfigOverloadThreshold OID is exceeded."
+ ::= {ePDU2BankConfigEntry 4}
+
+ePDU2BankConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined low load bank current threshold in Amps."
+ ::= {ePDU2BankConfigEntry 5}
+
+ePDU2BankConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined near bank overload current warning
+ threshold in Amps."
+ ::= {ePDU2BankConfigEntry 6}
+
+ePDU2BankConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined bank overload current threshold
+ in Amps"
+ ::= {ePDU2BankConfigEntry 7}
+
+ePDU2BankConfigPeakLoadReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the existing peak current value
+ to be replaced by the present load current value.
+
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= {ePDU2BankConfigEntry 8}
+
+ePDU2BankInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2BankInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU bank information."
+ ::= {ePDU2Bank 3}
+
+ePDU2BankInfoEntry OBJECT-TYPE
+ SYNTAX EPDU2BankInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information data from currently queried Rack PDU bank."
+ INDEX {ePDU2BankInfoIndex}
+ ::= {ePDU2BankInfoTable 1}
+
+EPDU2BankInfoEntryStruct ::=
+ SEQUENCE {
+ ePDU2BankInfoIndex INTEGER,
+ ePDU2BankInfoModuleIndex INTEGER,
+ ePDU2BankInfoNumber INTEGER
+ }
+
+ePDU2BankInfoIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..12)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank properties table entry."
+ ::= {ePDU2BankInfoEntry 1}
+
+ePDU2BankInfoModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2BankInfoEntry 2}
+
+ePDU2BankInfoNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric bank ID."
+ ::= {ePDU2BankInfoEntry 3}
+
+ePDU2BankStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2BankStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU bank status data"
+ ::= {ePDU2Bank 4}
+
+ePDU2BankStatusEntry OBJECT-TYPE
+ SYNTAX EPDU2BankStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Status data from currently queried Rack PDU bank"
+ INDEX {ePDU2BankStatusIndex}
+ ::= {ePDU2BankStatusTable 1}
+
+EPDU2BankStatusEntryStruct ::=
+ SEQUENCE {
+ ePDU2BankStatusIndex INTEGER,
+ ePDU2BankStatusModuleIndex INTEGER,
+ ePDU2BankStatusNumber INTEGER,
+ ePDU2BankStatusLoadState INTEGER,
+ ePDU2BankStatusLoad Gauge,
+ ePDU2BankStatusPeakLoad Gauge,
+ ePDU2BankStatusPeakLoadTimestamp DisplayString,
+ ePDU2BankStatusPeakLoadStartTime DisplayString
+ }
+
+ePDU2BankStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..12)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank status table entry."
+ ::= {ePDU2BankStatusEntry 1}
+
+ePDU2BankStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2BankStatusEntry 2}
+
+ePDU2BankStatusNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric bank ID."
+ ::= {ePDU2BankStatusEntry 3}
+
+ePDU2BankStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ lowLoad (2),
+ nearOverload (3),
+ overload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the present load status of the Rack
+ PDU bank being queried."
+ ::= {ePDU2BankStatusEntry 4}
+
+ePDU2BankStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the current draw, in tenths of Amps, of the load
+ on the Rack PDU bank being queried."
+ ::= {ePDU2BankStatusEntry 5}
+
+ePDU2BankStatusPeakLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak current of the Rack PDU bank load in tenths of Amps."
+ ::= {ePDU2BankStatusEntry 6}
+
+ePDU2BankStatusPeakLoadTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time the bank peak current occurred."
+ ::= {ePDU2BankStatusEntry 7}
+
+ePDU2BankStatusPeakLoadStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last bank peak current reset."
+ ::= {ePDU2BankStatusEntry 8}
+
+-- ePDU2Outlet
+ePDU2OutletSwitchedTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of switched outlets on connected Rack PDUs."
+ ::= {ePDU2OutletSwitched 1}
+
+ePDU2OutletSwitchedConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletSwitchedConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU switched outlet configuration data."
+ ::= {ePDU2OutletSwitched 2}
+
+ePDU2OutletSwitchedConfigEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletSwitchedConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Configuration data from currently queried Rack PDU
+ switched outlet."
+ INDEX {ePDU2OutletSwitchedConfigIndex}
+ ::= {ePDU2OutletSwitchedConfigTable 1}
+
+EPDU2OutletSwitchedConfigEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletSwitchedConfigIndex INTEGER,
+ ePDU2OutletSwitchedConfigModuleIndex INTEGER,
+ ePDU2OutletSwitchedConfigNumber INTEGER,
+ ePDU2OutletSwitchedConfigName DisplayString,
+ ePDU2OutletSwitchedConfigPowerOnTime INTEGER,
+ ePDU2OutletSwitchedConfigPowerOffTime INTEGER,
+ ePDU2OutletSwitchedConfigRebootDuration INTEGER
+ }
+
+ePDU2OutletSwitchedConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU switched outlet configuration table entry."
+ ::= {ePDU2OutletSwitchedConfigEntry 1}
+
+ePDU2OutletSwitchedConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2OutletSwitchedConfigEntry 2}
+
+ePDU2OutletSwitchedConfigNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric switched outlet ID."
+ ::= {ePDU2OutletSwitchedConfigEntry 3}
+
+ePDU2OutletSwitchedConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined switched outlet name string."
+ ::= {ePDU2OutletSwitchedConfigEntry 4}
+
+ePDU2OutletSwitchedConfigPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on at coldstart or when a command that requires
+ a turn-on delay is issued.
+
+ Allowed values are:
+ -1 - never power on.
+ 0 - power on immediately.
+ 1 to 7200 - power on up to 7200 seconds after being
+ commanded."
+ ::= {ePDU2OutletSwitchedConfigEntry 5}
+
+ePDU2OutletSwitchedConfigPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off when a command that requires a
+ turn-off delay is issued.
+
+ Allowed values are:
+ -1 - never power off.
+ 0 - power off immediately.
+ 1 to 7200 - power off up to 7200 seconds after being
+ commanded."
+ ::= {ePDU2OutletSwitchedConfigEntry 6}
+
+ePDU2OutletSwitchedConfigRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed range is any value between 5 and 60 seconds (1 minute)."
+ ::= {ePDU2OutletSwitchedConfigEntry 7}
+
+ePDU2OutletSwitchedInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletSwitchedInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU switched outlet information."
+ ::= {ePDU2OutletSwitched 3}
+
+ePDU2OutletSwitchedInfoEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletSwitchedInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information of the currently queried Rack PDU
+ switched outlet."
+ INDEX {ePDU2OutletSwitchedInfoIndex}
+ ::= {ePDU2OutletSwitchedInfoTable 1}
+
+EPDU2OutletSwitchedInfoEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletSwitchedInfoIndex INTEGER,
+ ePDU2OutletSwitchedInfoModuleIndex INTEGER,
+ ePDU2OutletSwitchedInfoNumber INTEGER,
+ ePDU2OutletSwitchedInfoName DisplayString,
+ ePDU2OutletSwitchedInfoPhaseLayout INTEGER,
+ ePDU2OutletSwitchedInfoBank INTEGER
+ }
+
+ePDU2OutletSwitchedInfoIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU switched outlet information table entry."
+ ::= {ePDU2OutletSwitchedInfoEntry 1}
+
+ePDU2OutletSwitchedInfoModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2OutletSwitchedInfoEntry 2}
+
+ePDU2OutletSwitchedInfoNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric switched outlet ID."
+ ::= {ePDU2OutletSwitchedInfoEntry 3}
+
+ePDU2OutletSwitchedInfoName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric switched outlet name."
+ ::= {ePDU2OutletSwitchedInfoEntry 4}
+
+ePDU2OutletSwitchedInfoPhaseLayout OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID describes the phase connections of the referenced outlet as follows:
+ seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2.
+ seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3.
+ seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1."
+ ::= {ePDU2OutletSwitchedInfoEntry 5}
+
+ePDU2OutletSwitchedInfoBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric bank ID."
+ ::= {ePDU2OutletSwitchedInfoEntry 6}
+
+ePDU2OutletSwitchedStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletSwitchedStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU switched outlet status information."
+ ::= {ePDU2OutletSwitched 4}
+
+ePDU2OutletSwitchedStatusEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletSwitchedStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Status information for currently queried Rack PDU switched outlet."
+ INDEX {ePDU2OutletSwitchedStatusIndex}
+ ::= {ePDU2OutletSwitchedStatusTable 1}
+
+EPDU2OutletSwitchedStatusEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletSwitchedStatusIndex INTEGER,
+ ePDU2OutletSwitchedStatusModuleIndex INTEGER,
+ ePDU2OutletSwitchedStatusNumber INTEGER,
+ ePDU2OutletSwitchedStatusName DisplayString,
+ ePDU2OutletSwitchedStatusState INTEGER,
+ ePDU2OutletSwitchedStatusCommandPending INTEGER
+ }
+
+ePDU2OutletSwitchedStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU switched outlet status information table entry."
+ ::= {ePDU2OutletSwitchedStatusEntry 1}
+
+ePDU2OutletSwitchedStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2OutletSwitchedStatusEntry 2}
+
+ePDU2OutletSwitchedStatusNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric switched outlet ID."
+ ::= {ePDU2OutletSwitchedStatusEntry 3}
+
+ePDU2OutletSwitchedStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined switched outlet name string."
+ ::= {ePDU2OutletSwitchedStatusEntry 4}
+
+ePDU2OutletSwitchedStatusState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusOn (1),
+ outletStatusOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the present switch state of the Rack PDU switched outlet being queried."
+ ::= {ePDU2OutletSwitchedStatusEntry 5}
+
+ePDU2OutletSwitchedStatusCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusCommandPending (1),
+ outletStatusNoCommandPending (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending state of the outlet.
+ If a command is pending on the outlet, the outletStatusCommandPending (1)
+ value will be returned. If there is not a command pending on the outlet,
+ the outletStatusNoCommandPending (2) will be returned."
+ ::= {ePDU2OutletSwitchedStatusEntry 6}
+
+ePDU2OutletSwitchedControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletSwitchedControlEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU switched outlet control data."
+ ::= {ePDU2OutletSwitched 5}
+
+ePDU2OutletSwitchedControlEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletSwitchedControlEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Control data for currently queried Rack PDU switched outlet."
+ INDEX {ePDU2OutletSwitchedControlIndex}
+ ::= {ePDU2OutletSwitchedControlTable 1}
+
+EPDU2OutletSwitchedControlEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletSwitchedControlIndex INTEGER,
+ ePDU2OutletSwitchedControlModuleIndex INTEGER,
+ ePDU2OutletSwitchedControlNumber INTEGER,
+ ePDU2OutletSwitchedControlName DisplayString,
+ ePDU2OutletSwitchedControlCommand INTEGER
+ }
+
+ePDU2OutletSwitchedControlIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU switched outlet control data table entry."
+ ::= {ePDU2OutletSwitchedControlEntry 1}
+
+ePDU2OutletSwitchedControlModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined Rack PDU numeric ID."
+ ::= {ePDU2OutletSwitchedControlEntry 2}
+
+ePDU2OutletSwitchedControlNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric switched outlet ID."
+ ::= {ePDU2OutletSwitchedControlEntry 3}
+
+ePDU2OutletSwitchedControlName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined switched outlet name string."
+ ::= {ePDU2OutletSwitchedControlEntry 4}
+
+ePDU2OutletSwitchedControlCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOn (1),
+ immediateOff (2),
+ immediateReboot (3),
+ delayedOn (4),
+ delayedOff (5),
+ delayedReboot (6),
+ cancelPendingCommand (7),
+ outletIdentify (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOn (1) value will be returned.
+ If the outlet is off, the immediateOff (2) value will be returned.
+
+ Setting this variable to immediateOn (1) will immediately turn
+ the outlet on.
+
+ Setting this variable to immediateOff (2) will immediately turn
+ the outlet off.
+
+ Setting this variable to immediateReboot (3) will immediately
+ reboot the outlet.
+
+ Setting this variable to delayedOn (4) will turn the outlet on
+ after the ePDUOutletConfigPowerOnTime OID time has elapsed.
+
+ Setting this variable to delayedOff (5) will turn the outlet off
+ after the ePDUOutletConfigPowerOffTime OID time has elapsed.
+
+ Setting this variable to delayedReboot (6) will cause the
+ Switched Rack PDU to perform a delayedOff command, wait the
+ ePDUOutletConfigRebootDuration OID time, and then perform a
+ delayedOn command.
+
+ Setting this variable to cancelPendingCommand (7) will cause any
+ pending command to this outlet to be canceled.
+
+ Setting this variable to outletIdentify (8) will cause PDU LED
+ to display the number of the outlet."
+ ::= {ePDU2OutletSwitchedControlEntry 5}
+
+ePDU2OutletMeteredTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of metered outlets on connected Rack PDUs."
+ ::= {ePDU2OutletMetered 1}
+
+ePDU2OutletMeteredConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletMeteredConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU metered outlet configuration data."
+ ::= {ePDU2OutletMetered 2}
+
+ePDU2OutletMeteredConfigEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletMeteredConfigEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Configuration data from currently queried Rack PDU metered outlet."
+ INDEX {ePDU2OutletMeteredConfigIndex}
+ ::= {ePDU2OutletMeteredConfigTable 1}
+
+EPDU2OutletMeteredConfigEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletMeteredConfigIndex INTEGER,
+ ePDU2OutletMeteredConfigModuleIndex INTEGER,
+ ePDU2OutletMeteredConfigNumber INTEGER,
+ ePDU2OutletMeteredConfigName DisplayString,
+ ePDU2OutletMeteredConfigLowLoadThreshold INTEGER,
+ ePDU2OutletMeteredConfigNearOverloadThreshold INTEGER,
+ ePDU2OutletMeteredConfigOverloadThreshold INTEGER
+ }
+
+ePDU2OutletMeteredConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU metered outlet configuration table entry."
+ ::= {ePDU2OutletMeteredConfigEntry 1}
+
+ePDU2OutletMeteredConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined Rack PDU numeric ID."
+ ::= {ePDU2OutletMeteredConfigEntry 2}
+
+ePDU2OutletMeteredConfigNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric metered outlet ID."
+ ::= {ePDU2OutletMeteredConfigEntry 3}
+
+ePDU2OutletMeteredConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined metered outlet name string."
+ ::= {ePDU2OutletMeteredConfigEntry 4}
+
+ePDU2OutletMeteredConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined outlet low load current threshold in Watts."
+ ::= {ePDU2OutletMeteredConfigEntry 5}
+
+ePDU2OutletMeteredConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined outlet near overload warning threshold in Watts."
+ ::= {ePDU2OutletMeteredConfigEntry 6}
+
+ePDU2OutletMeteredConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "User-defined outlet overload current threshold in Watts."
+ ::= {ePDU2OutletMeteredConfigEntry 7}
+
+ePDU2OutletMeteredInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletMeteredInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU metered outlet information."
+ ::= {ePDU2OutletMetered 3}
+
+ePDU2OutletMeteredInfoEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletMeteredInfoEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information of currently queried Rack PDU metered outlet."
+ INDEX {ePDU2OutletMeteredInfoIndex}
+ ::= {ePDU2OutletMeteredInfoTable 1}
+
+EPDU2OutletMeteredInfoEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletMeteredInfoIndex INTEGER,
+ ePDU2OutletMeteredInfoModuleIndex INTEGER,
+ ePDU2OutletMeteredInfoNumber INTEGER,
+ ePDU2OutletMeteredInfoName DisplayString,
+ ePDU2OutletMeteredInfoLayout INTEGER,
+ ePDU2OutletMeteredInfoRating INTEGER,
+ ePDU2OutletMeteredInfoBank INTEGER
+ }
+
+ePDU2OutletMeteredInfoIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU metered information table entry."
+ ::= {ePDU2OutletMeteredInfoEntry 1}
+
+ePDU2OutletMeteredInfoModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2OutletMeteredInfoEntry 2}
+
+ePDU2OutletMeteredInfoNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric metered outlet ID."
+ ::= {ePDU2OutletMeteredInfoEntry 3}
+
+ePDU2OutletMeteredInfoName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined metered outlet name string."
+ ::= {ePDU2OutletMeteredInfoEntry 4}
+
+ePDU2OutletMeteredInfoLayout OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID describes the phase connections of the referenced outlet as follows:
+ seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2.
+ seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3.
+ seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1."
+ ::= {ePDU2OutletMeteredInfoEntry 5}
+
+ePDU2OutletMeteredInfoRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum power rating of Rack PDU metered outlet."
+ ::= {ePDU2OutletMeteredInfoEntry 6}
+
+ePDU2OutletMeteredInfoBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This outlet's numeric bank ID."
+ ::= {ePDU2OutletMeteredInfoEntry 7}
+
+ePDU2OutletMeteredStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EPDU2OutletMeteredStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Rack PDU metered outlet status data."
+ ::= {ePDU2OutletMetered 4}
+
+ePDU2OutletMeteredStatusEntry OBJECT-TYPE
+ SYNTAX EPDU2OutletMeteredStatusEntryStruct
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Status data from currently queried Rack PDU metered outlet."
+ INDEX {ePDU2OutletMeteredStatusIndex}
+ ::= {ePDU2OutletMeteredStatusTable 1}
+
+EPDU2OutletMeteredStatusEntryStruct ::=
+ SEQUENCE {
+ ePDU2OutletMeteredStatusIndex INTEGER,
+ ePDU2OutletMeteredStatusModuleIndex INTEGER,
+ ePDU2OutletMeteredStatusNumber INTEGER,
+ ePDU2OutletMeteredStatusName DisplayString,
+ ePDU2OutletMeteredStatusAlarm INTEGER,
+ ePDU2OutletMeteredStatusLoad Gauge,
+ ePDU2OutletMeteredStatusActivePower Gauge,
+ ePDU2OutletMeteredStatusPeakPower Gauge,
+ ePDU2OutletMeteredStatusPeakPowerTimestamp DisplayString,
+ ePDU2OutletMeteredStatusPeakPowerStartTime DisplayString,
+ ePDU2OutletMeteredStatusEnergy Gauge,
+ ePDU2OutletMeteredStatusEnergyStart DisplayString
+ }
+
+ePDU2OutletMeteredStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU metered status table entry."
+ ::= {ePDU2OutletMeteredStatusEntry 1}
+
+ePDU2OutletMeteredStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU numeric ID."
+ ::= {ePDU2OutletMeteredStatusEntry 2}
+
+ePDU2OutletMeteredStatusNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The numeric metered outlet ID."
+ ::= {ePDU2OutletMeteredStatusEntry 3}
+
+ePDU2OutletMeteredStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user-defined metered outlet name string."
+ ::= {ePDU2OutletMeteredStatusEntry 4}
+
+ePDU2OutletMeteredStatusAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLoadAlarm (1),
+ underCurrentAlarm (2),
+ nearOverCurrentAlarm (3),
+ overCurrentAlarm (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the current outlet alarm."
+ ::= {ePDU2OutletMeteredStatusEntry 5}
+
+ePDU2OutletMeteredStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the measured Outlet load
+ for an Outlet Monitored Rack PDU in tenths of Amps."
+ ::= {ePDU2OutletMeteredStatusEntry 6}
+
+ePDU2OutletMeteredStatusActivePower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the measured Outlet load for
+ an Outlet Monitored Rack PDU in watts."
+ ::= {ePDU2OutletMeteredStatusEntry 7}
+
+ePDU2OutletMeteredStatusPeakPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The peak power consumption of the Rack PDU load in watts."
+ ::= {ePDU2OutletMeteredStatusEntry 8}
+
+ePDU2OutletMeteredStatusPeakPowerTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the date and time that peak power
+ consumption occurred."
+ ::= {ePDU2OutletMeteredStatusEntry 9}
+
+ePDU2OutletMeteredStatusPeakPowerStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid shows the date and time that peak power
+ consumption started."
+ ::= {ePDU2OutletMeteredStatusEntry 10}
+
+ePDU2OutletMeteredStatusEnergy OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Energy meter measuring Rack PDU load energy consumption
+ in tenths of kilowatt-hours."
+ ::= {ePDU2OutletMeteredStatusEntry 11}
+
+ePDU2OutletMeteredStatusEnergyStart OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the date and time of the last device energy
+ meter reset."
+ ::= {ePDU2OutletMeteredStatusEntry 12}
+
+-- ePDU2Sensor
+ePDU2SensorTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "ePDU2SensorTableSize"
+ ::= {ePDU2Sensor 1}
+
+-- ePDU2Group
+ePDU2GroupNumberOfDevices OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of Rack PDU devices contributing
+ to the Daisy Chain group power and energy values. Queries
+ to slave units in an Daisy Chain group will return 0."
+ ::= {ePDU2Group 1}
+
+ePDU2GroupTotalPower OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the total power consumption of the Rack PDU
+ Daisy Chain group devices in watts. Queries to slave
+ units in an Daisy Chain group will return 0."
+ ::= {ePDU2Group 2}
+
+ePDU2GroupTotalEnergy OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the total energy consumption of the Rack
+ PDU Daisy Chain group devices in tenths of kilowatt-hours.
+
+ To reset the energy meters for each of the Rack PDU devices that contribute
+ to this value, see the ePDU2GroupEnergyReset OID.
+
+ To view the start time for each of the Rack PDU device energy meters that
+ contribute to this value, see the ePDU2DeviceStatusEnergyStartTime OID.
+
+ Queries to slave units in an Daisy Chain group will return 0."
+ ::= {ePDU2Group 3}
+
+ePDU2GroupEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the device energy meter value
+ on each device in the Rack PDU Daisy Chain group to be reset to zero.
+
+ Getting this OID in models that support this feature will do nothing
+ and return the noOperation(1) value."
+ ::= {ePDU2Group 4}
+
+ePDU2GroupPeakRecordReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the device peak record value
+ on each device in the Rack PDU Daisy Chain group to be reset to current
+ load/power.
+
+ Getting this OID in models that support this feature will do nothing
+ and return the noOperation(1) value."
+ ::= {ePDU2Group 5}
+
+-- Battery Manager
+bmIdentModelName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager model name."
+ ::= { bmIdent 1 }
+
+bmIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager hardware version."
+ ::= { bmIdent 2 }
+
+bmIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager firmware version."
+ ::= { bmIdent 3 }
+
+bmIdentLCDHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager LCD hardware version."
+ ::= { bmIdent 4 }
+
+bmIdentLCDFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager LCD firmware version."
+ ::= { bmIdent 5 }
+
+bmIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager manufacture date."
+ ::= { bmIdent 6 }
+
+bmIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager serial number."
+ ::= { bmIdent 7 }
+
+bmIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager system identification name."
+ ::= { bmIdent 8 }
+
+bmIdentLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager system location."
+ ::= { bmIdent 9 }
+
+bmPropertyStringMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager max string count supported."
+ ::= { bmProperty 1 }
+
+bmPropertyMaxProbeOnString OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager max probes on a string supported."
+ ::= { bmProperty 2 }
+
+bmPropertyInputVoltageRange OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager line input voltage range."
+ ::= { bmProperty 3 }
+
+bmPropertyProbesRating OBJECT-TYPE
+ SYNTAX INTEGER {
+ probeUnknown(1),
+ probe2V(2),
+ probe4V(3),
+ probe6V(4),
+ probe12V(5),
+ probeMixed(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery probes model rating."
+ ::= { bmProperty 4 }
+
+bmConfigBattAH OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager battery AH type configuration, unit in 0.1 AH."
+ ::= { bmConfig 1 }
+
+bmConfigStringCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager string count setting."
+ ::= { bmConfig 2 }
+
+bmConfigProbesCountOnString OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager probe count on a string setting."
+ ::= { bmConfig 3 }
+
+bmConfigLowVoltAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low voltage alarm threshold setting, unit in 0.1 volt."
+ ::= { bmConfig 4 }
+
+bmConfigHighVoltAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high voltage alarm threshold setting, unit in 0.1 volt."
+ ::= { bmConfig 5 }
+
+bmConfigVoltDiffAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Batteries within a string voltage difference threshold, unit in 0.1 volt."
+ ::= { bmConfig 6 }
+
+bmConfigLowTempAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low temperature alarm threshold, unit in 0.1 degree C."
+ ::= { bmConfig 7 }
+
+bmConfigHighTempAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high temperature alarm threshold, unit in 0.1 degree C."
+ ::= { bmConfig 8 }
+
+bmConfigLowResAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low resistance alarm threshold, unit in 0.01 mOhm."
+ ::= { bmConfig 9 }
+
+bmConfigHighResAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high resistance alarm threshold, unit in 0.01 mOhm."
+ ::= { bmConfig 10 }
+
+bmConfigLowResWarnThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low resistance warning threshold, unit in 0.01 mOhm."
+ ::= { bmConfig 11 }
+
+bmConfigHighResWarnThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high resistance warning threshold, unit in 0.01 mOhm."
+ ::= { bmConfig 12 }
+
+bmConfigResHealthAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery resistance health alarm threshold, unit in percentage and should larger than 100."
+ ::= { bmConfig 13 }
+
+bmConfigResHealthWarnThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery resistance health warn threshold, unit in percentage and should larger than 100."
+ ::= { bmConfig 14 }
+
+bmConfigLowVoltAlarmThreshold10mV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low voltage alarm threshold setting, unit in 10 mV (0.01 volt)."
+ ::= { bmConfig 15 }
+
+bmConfigHighVoltAlarmThreshold10mV OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high voltage alarm threshold setting, unit in 10 mV (0.01 volt)."
+ ::= { bmConfig 16 }
+
+bmConfigMergeFeature OBJECT-TYPE
+ SYNTAX INTEGER{
+ enable (1),
+ disable (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "String merge feature setting."
+ ::= { bmConfig 17 }
+
+bmControlSysytemIdenticator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager will perform a panel indicator test when the variable is set to testIndicators(2).
+ Get this oid will get noTestIndicators(1)."
+ ::= { bmControl 1 }
+
+bmControlProbeIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery manager will perform a probe indicator test when the variable is set to testIndicators(2).
+ Get this oid will get noTestIndicators(1)."
+ ::= { bmControl 2 }
+
+bmProbesNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current connected probe number."
+ ::= { bmProbes 1 }
+
+bmProbesTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current configured probe number."
+ ::= { bmProbes 2 }
+
+bmProbesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BmProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of probes."
+ ::= { bmProbes 3 }
+
+bmProbesEntry OBJECT-TYPE
+ SYNTAX BmProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of probes installation to gather status from."
+ INDEX { bmProbesIndex }
+ ::= { bmProbesTable 1 }
+
+BmProbesEntry ::=
+ SEQUENCE {
+ bmProbesIndex INTEGER,
+ bmProbesPackIndex INTEGER,
+ bmProbesStringIndex INTEGER,
+ bmProbesBattIndex INTEGER
+ }
+
+bmProbesIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probes table index"
+ ::= { bmProbesEntry 1 }
+
+bmProbesPackIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery pack number the probe installed."
+ ::= { bmProbesEntry 2 }
+
+bmProbesStringIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The string number the probe installed."
+ ::= { bmProbesEntry 3 }
+
+bmProbesBattIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery number the probe installed."
+ ::= { bmProbesEntry 4 }
+
+bmProbesVoltageTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the battery voltage table"
+ ::= { bmProbes 4 }
+
+bmProbesVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BmProbesVoltageEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of voltage of batteries."
+ ::= { bmProbes 5 }
+
+bmProbesVoltageEntry OBJECT-TYPE
+ SYNTAX BmProbesVoltageEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Batteries voltage status."
+ INDEX { bmProbesVoltageIndex}
+ ::= { bmProbesVoltageTable 1 }
+
+BmProbesVoltageEntry ::=
+ SEQUENCE {
+ bmProbesVoltageIndex INTEGER,
+ bmProbesVoltagePackIndex INTEGER,
+ bmProbesVoltageStringIndex INTEGER,
+ bmProbesVoltageBattIndex INTEGER,
+ bmProbesVoltageProbeIndex INTEGER,
+ bmProbesVoltageAlarmStatus INTEGER,
+ bmProbesVoltage INTEGER,
+ bmProbesVoltageEqualPercentage INTEGER
+ }
+
+bmProbesVoltageIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the voltage status entry."
+ ::= { bmProbesVoltageEntry 1 }
+
+bmProbesVoltagePackIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery pack index to the voltage record."
+ ::= { bmProbesVoltageEntry 2 }
+
+bmProbesVoltageStringIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery string index to the voltage record."
+ ::= { bmProbesVoltageEntry 3 }
+
+bmProbesVoltageBattIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery index to the voltage record within its string."
+ ::= { bmProbesVoltageEntry 4 }
+
+bmProbesVoltageProbeIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The probe index to the voltage record."
+ ::= { bmProbesVoltageEntry 5 }
+
+bmProbesVoltageAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ voltageNormal(1),
+ voltageWarnLow(2),
+ voltageWarnHigh(3),
+ voltageAlarmLow(4),
+ voltageAlarmHigh(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery voltage alarm status."
+ ::= { bmProbesVoltageEntry 6 }
+
+bmProbesVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this oid to get battery voltage, unit in 10mV (0.01 volt)."
+ ::= { bmProbesVoltageEntry 7 }
+
+bmProbesVoltageEqualPercentage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this oid to get battery voltage equalizing power, unit in percentage."
+ ::= { bmProbesVoltageEntry 8 }
+
+bmProbesTempTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Temperature table"
+ ::= { bmProbes 6 }
+
+bmProbesTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BmProbesTempEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of temperature of probes."
+ ::= { bmProbes 7 }
+
+bmProbesTempEntry OBJECT-TYPE
+ SYNTAX BmProbesTempEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Temperature status entry."
+ INDEX { bmProbesTempIndex }
+ ::= { bmProbesTempTable 1 }
+
+BmProbesTempEntry ::=
+ SEQUENCE {
+ bmProbesTempIndex INTEGER,
+ bmProbesTempPackIndex INTEGER,
+ bmProbesTempStringIndex INTEGER,
+ bmProbesTempBattIndex INTEGER,
+ bmProbesTempProbeIndex INTEGER,
+ bmProbesTempAlarmStatus INTEGER,
+ bmProbesTemperature INTEGER
+ }
+
+bmProbesTempIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the temperature entry."
+ ::= { bmProbesTempEntry 1 }
+
+bmProbesTempPackIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery pack index of the temperature entry."
+ ::= { bmProbesTempEntry 2 }
+
+bmProbesTempStringIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the string."
+ ::= { bmProbesTempEntry 3 }
+
+bmProbesTempBattIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the battery."
+ ::= { bmProbesTempEntry 4 }
+
+bmProbesTempProbeIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the probe."
+ ::= { bmProbesTempEntry 5 }
+
+bmProbesTempAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ temperatureNormal(1),
+ temperatureWarnLow(2),
+ temperatureWarnHigh(3),
+ temperatureAlarmLow(4),
+ temperatureAlarmHigh(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm status of the temperature."
+ ::= { bmProbesTempEntry 6 }
+
+bmProbesTemperature OBJECT-TYPE
+ SYNTAX INTEGER(-40..60)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature record, measure in 0.1 degree C."
+ ::= { bmProbesTempEntry 7 }
+
+bmProbesResTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The size of the Resistance table"
+ ::= { bmProbes 8 }
+
+bmProbesResTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BmProbesResEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of resistance of probes."
+ ::= { bmProbes 9 }
+
+bmProbesResEntry OBJECT-TYPE
+ SYNTAX BmProbesResEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The resistance status entry."
+ INDEX { bmProbesResIndex }
+ ::= { bmProbesResTable 1 }
+
+BmProbesResEntry ::=
+ SEQUENCE {
+ bmProbesResIndex INTEGER,
+ bmProbesResPackIndex INTEGER,
+ bmProbesResStringIndex INTEGER,
+ bmProbesResBattIndex INTEGER,
+ bmProbesResProbeIndex INTEGER,
+ bmProbesResAlarmStatus INTEGER,
+ bmProbesResistance INTEGER,
+ bmProbesResHealth INTEGER
+ }
+
+bmProbesResIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the resistance entry."
+ ::= { bmProbesResEntry 1 }
+
+bmProbesResPackIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery pack index to the resistance entry."
+ ::= { bmProbesResEntry 2 }
+
+bmProbesResStringIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..16)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the string."
+ ::= { bmProbesResEntry 3 }
+
+bmProbesResBattIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the battery."
+ ::= { bmProbesResEntry 4 }
+
+bmProbesResProbeIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..960)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the probe."
+ ::= { bmProbesResEntry 5 }
+
+bmProbesResAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ resistanceNormal(1),
+ resistanceWarnLow(2),
+ resistanceWarnHigh(3),
+ resistanceAlarmLow(4),
+ resistanceAlarmHigh(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm status of the battery resistance."
+ ::= { bmProbesResEntry 6 }
+
+bmProbesResistance OBJECT-TYPE
+ SYNTAX INTEGER(-40..60)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The resistance of the battery, unit in 0.01 mOhm."
+ ::= { bmProbesResEntry 7 }
+
+bmProbesResHealth OBJECT-TYPE
+ SYNTAX INTEGER(-40..60)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The resistance health status, unit in percentage."
+ ::= { bmProbesResEntry 8 }
+
+bmFuncResMeasureInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time interval for battery manager to exercising resistance measurement, unit in hour(s)."
+ ::= { bmFuncResMeasure 1 }
+
+bmFuncResMeasureManualCmd OBJECT-TYPE
+ SYNTAX INTEGER {
+ noResMeasure(1),
+ resMeasureNow(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This oid allows user to manual resistance measurement.
+ Set this oid to measureResNow(2) to measure resistance immediately.
+
+ Get bmFuncResMeasureLastCmdResult oid to check command acceptance.
+ "
+ ::= { bmFuncResMeasure 2 }
+
+bmFuncResMeasureManualResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ resNoManualResult(1),
+ resManualProcessing(2),
+ resManualComplete(3),
+ resManualReject(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Get this oid to confirm the last manual command result."
+ ::= { bmFuncResMeasure 3 }
+
+bmFuncResMeasureLastUpdate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When resistance measurement complete either by auto or manual,
+ this oid will update to the last update time."
+ ::= { bmFuncResMeasure 4 }
+
+bmFuncEqualEnable OBJECT-TYPE
+ SYNTAX INTEGER{
+ enable (1),
+ disable (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery voltage equalization configuration."
+ ::= { bmFuncEqual 1 }
+
+bmFuncEqualActiveCond OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Volatge equalization will active when the voltage difference larger than this value, unit in 10mV."
+ ::= { bmFuncEqual 2 }
+
+bmFuncEqualStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ equalActive(1),
+ equalFailed(2),
+ equalNotActive(3),
+ equalNotSupport(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This oid shows the current equalization status."
+ ::= { bmFuncEqual 3 }
+
+bmFuncEqualStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This oid shows the last equalization start time."
+ ::= { bmFuncEqual 4 }
+
+bmFuncEqualElapseTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This oid shows the elapsed time since last equalization started."
+ ::= { bmFuncEqual 5 }
+
+-- Traps
+-- Annotations are provided for Novell's NMS product
+communicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Communication with the UPS has been lost."
+ --#TYPE "CPS UPS: Communication lost"
+ --#SUMMARY "Communication with the UPS has been lost."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 1
+
+upsOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS has sensed an overload condition."
+ --#TYPE "CPS UPS: Overload"
+ --#SUMMARY "The UPS has sensed an overload condition."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 2
+
+upsDiagnosticsFailed TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS battery test failed."
+ --#TYPE "CPS UPS: battery test failed"
+ --#SUMMARY "The UPS battery test failed."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 3
+
+upsDischarged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS has started a runtime estimation process."
+ --#TYPE "CPS UPS: batteries are discharged"
+ --#SUMMARY "The UPS has started a runtime estimation process."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 4
+
+upsOnBattery TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Utility power failed, transfer to backup mode."
+ --#TYPE "CPS UPS: The UPS is on battery"
+ --#SUMMARY "Utility power failed, transfer to backup mode."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 5
+
+upsBoostOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS has enabled boost, low utility voltage."
+ --#TYPE "CPS UPS: Boost enable"
+ --#SUMMARY "The UPS has enabled boost, low utility voltage."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 6
+
+lowBattery TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS battery capacity is low than threshold, soon to be exhausted."
+ --#TYPE "CPS UPS: Low battery"
+ --#SUMMARY "The UPS battery capacity is low than threshold, soon to be exhausted."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 7
+
+communicationEstablished TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication to the UPS has been established."
+ --#TYPE "CPS UPS: Communication established"
+ --#SUMMARY "Communication to the UPS has been established."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 8
+
+powerRestored TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility power restored, return from backup mode."
+ --#TYPE "CPS UPS: Power restored"
+ --#SUMMARY "Utility power restored, return from backup mode."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 9
+
+upsDiagnosticsPassed TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS battery test passed."
+ --#TYPE "CPS UPS: Selftest passed"
+ --#SUMMARY "The UPS battery test passed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 10
+
+returnFromLowBattery TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has returned from a low battery condition."
+ --#TYPE "CPS UPS: Low battery condition cleared"
+ --#SUMMARY "The UPS has returned from a low battery condition."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 11
+
+upsTurnedOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS has been turned off."
+ --#TYPE "CPS UPS: UPS turned off"
+ --#SUMMARY "The UPS has been turned off."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 12
+
+upsSleeping TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS entered sleep mode. Output power will not be provided."
+ --#TYPE "CPS UPS: Entered sleep mode"
+ --#SUMMARY "The UPS entered sleep mode. Output power will not be provided."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 13
+
+upsWokeUp TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The UPS woke up from sleep mode. Output power is being provided."
+ --#TYPE "CPS UPS: UPS woke up"
+ --#SUMMARY "The UPS woke up from sleep mode. Output power is being provided."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 14
+
+upsRebootStarted TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS started reboot sequence."
+ --#TYPE "CPS UPS: Starting reboot"
+ --#SUMMARY "The UPS started reboot sequence."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 15
+
+upsOverTemp TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS inner temperature is too high."
+ --#TYPE "CPS UPS: UPS over temperature"
+ --#SUMMARY "The UPS inner temperature is too high."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 16
+
+returnFromOverTemp TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS over temperature condition cleared."
+ --#TYPE "CPS UPS: UPS over temperature cleared"
+ --#SUMMARY "The UPS over temperature condition cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 17
+
+upsBuckOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS has enabled buck, high utility voltage."
+ --#TYPE "CPS UPS: Buck enable"
+ --#SUMMARY "The UPS has enabled buck, high utility voltage."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 18
+
+returnFromOverLoad TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has returned from an overload condition."
+ --#TYPE "CPS UPS: Returned from overload condition"
+ --#SUMMARY "The UPS has returned from an overload condition."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 19
+
+returnFromDischarged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS runtime estimation completed."
+ --#TYPE "CPS UPS: Discharged condition cleared"
+ --#SUMMARY "The UPS runtime estimation completed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 20
+
+upsScheduleShutdown TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS has started its schedule shutdown sequence."
+ --#TYPE "CPS UPS: Schedule shutdown"
+ --#SUMMARY "The UPS has started its schedule shutdown sequence."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 21
+
+upsEnterSleep TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS started sleep sequence."
+ --#TYPE "CPS UPS: Entered sleep mode sequence"
+ --#SUMMARY "The UPS started sleep sequence."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 22
+
+upsChargerFailure TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The battery charger is abnormal."
+ --#TYPE "CPS UPS: The charger failed."
+ --#SUMMARY "The battery charger is abnormal."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 23
+
+returnFromChargerFailure TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The charger returned from a failure condition."
+ --#TYPE "CPS UPS: The charger failure cleared"
+ --#SUMMARY "The charger returned from a failure condition."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 24
+
+upsTurnoffStarted TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS started turn off sequence."
+ --#TYPE "CPS UPS: Starting turn off"
+ --#SUMMARY "The UPS started its turn off sequence."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 25
+
+upsTurnedOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS has been turned on."
+ --#TYPE "CPS UPS: UPS turned on"
+ --#SUMMARY "The UPS has been turned on."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 26
+
+upsRemoteCommandFailed TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS remote command failed."
+ --#TYPE "CPS UPS: Command failed"
+ --#SUMMARY "The UPS remote command failed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 27
+
+upsLostRedundant TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Not enough power redundancy modules."
+ --#TYPE "CPS UPS: lost redundancy"
+ --#SUMMARY "Not enough power redundancy modules."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 28
+
+upsSignalClientShutdown TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: The UPS has signaled clients to shutdown."
+ --#TYPE "CPS UPS: Signal clients to shutdown"
+ --#SUMMARY "The UPS has signaled clients to shutdown."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 29
+
+upsEmergencyPowerOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Emergency Power Off (EPO)"
+ --#TYPE "CPS UPS: Emergency Power Off (EPO)"
+ --#SUMMARY "Emergency Power Off (EPO)"
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 30
+
+-- Outlet Traps
+nclBankOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Non-Critical bank has been turned on."
+ --#TYPE "CPS UPS: NCL bank turned on."
+ --#SUMMARY "Non-Critical bank has been turned on"
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 31
+
+nclBankOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Non-Critical bank has been turned off."
+ --#TYPE "CPS UPS: NCL bank turned off."
+ --#SUMMARY "Non-Critical bank has been turned off"
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 32
+
+upsCommandCancel TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The cancel command has been executed."
+ --#TYPE "CPS UPS: Ups command canceled."
+ --#SUMMARY "The cancel command has been executed."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 33
+
+upsStartBatteryTest TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The UPS has started a battery test process."
+ --#TYPE "CPS UPS: UPS selftest start."
+ --#SUMMARY "The UPS has started a battery test process."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 34
+
+upsRemainRuntimeLowThanThreshold TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS remaining runtime is lower than threshold."
+ --#TYPE "CPS UPS: Low remaining runtime."
+ --#SUMMARY "The UPS remaining runtime us lower than threshold."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 35
+
+nclBankStartScheduleOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Non-Critial bank has started its schedule off sequence."
+ --#TYPE "CPS UPS: NCL bank started scheduled off sequence."
+ --#SUMMARY "Non-Critial bank has started its schedule off sequence."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 36
+
+upsEstimationAbort TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS runtime estimation aborted."
+ --#TYPE "CPS UPS: Runtime estimation aborted."
+ --#SUMMARY "The UPS runtime estimation aborted."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 37
+
+upsHardwareFault TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS hardware fault."
+ --#TYPE "CPS UPS: Hardware fault."
+ --#SUMMARY "The UPS hardware fault."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 38
+
+upsBatteryNotPresent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Battery is not present."
+ --#TYPE "CPS UPS: Battery is not present."
+ --#SUMMARY "Battery is not present."
+ --#SEVERITY INFORMATION
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#STATE OPERATIONAL
+ ::= 39
+
+-- OL extension event: Wiring Fault
+upsWiringFault TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS wiring fault has been detected."
+ --#TYPE "The UPS wiring fault has been detected."
+ --#SUMMARY "The UPS wiring fault has been detected."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 40
+
+upsWiringFaultCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The UPS wiring fault has been cleared."
+ --#TYPE "The UPS wiring fault has been cleared."
+ --#SUMMARY "The UPS wiring fault has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 41
+
+upsEnterBypassMode TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS enters bypass mode."
+ --#TYPE "The UPS enters bypass mode"
+ --#SUMMARY "The UPS enters bypass mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 42
+
+upsReturnFromBypassMode TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The UPS leaves bypass mode."
+ --#TYPE "The UPS leaves bypass mode."
+ --#SUMMARY "The UPS leaves bypass mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 43
+
+upsBypassOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS bypass overload."
+ --#TYPE "The UPS bypass overload."
+ --#SUMMARY "The UPS bypass overload."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 44
+
+upsBypassOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The UPS bypass overload has been cleared."
+ --#TYPE "The UPS bypass overload has been cleared."
+ --#SUMMARY "The UPS bypass overload has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 45
+
+upsEnterECOMode TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS enters ECO mode."
+ --#TYPE "The UPS enters ECO mode"
+ --#SUMMARY "The UPS enters ECO mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 46
+
+upsReturnFromECOMode TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The UPS leaves ECO mode."
+ --#TYPE "The UPS leaves ECO mode"
+ --#SUMMARY "The UPS leaves ECO mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 47
+
+upsBatteryOverThreeYear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Battery has been 3 years from last Replacement."
+ --#TYPE "Battery has been 3 years from last Replacement."
+ --#SUMMARY "Battery has been 3 years from last Replacement."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 48
+
+upsBatteryExpiration TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The battery may not work well anymore."
+ --#TYPE "The battery may not work well anymore."
+ --#SUMMARY "The battery may not work well anymore."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 49
+
+upsBatteryReplacement TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The battery has been replaced."
+ --#TYPE "The battery has been replaced."
+ --#SUMMARY "The battery has been replaced."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 50
+
+upsModuleInvertorAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The UPS module invertor alarm."
+ --#TYPE "The UPS module invertor alarm."
+ --#SUMMARY "The UPS module invertor alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 51
+
+upsModuleRectifierAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The UPS module rectifier alarm."
+ --#TYPE "The UPS module rectifier alarm."
+ --#SUMMARY "The UPS module rectifier alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 52
+
+upsModuleFanAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The UPS module fan alarm."
+ --#TYPE "The UPS module fan alarm."
+ --#SUMMARY "The UPS module fan alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 53
+
+upsModuleManualShutdown TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The UPS module manual shutdown."
+ --#TYPE "The UPS module manual shutdown."
+ --#SUMMARY "The UPS module manual shutdown."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 54
+
+upsModuleOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: The UPS module overload."
+ --#TYPE "The UPS module overload."
+ --#SUMMARY "The UPS module overload."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 55
+
+upsFirmwareUpgradeStart TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: UPS firmware starts to update."
+ --#TYPE "UPS firmware starts to update."
+ --#SUMMARY "UPS firmware starts to update."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 56
+
+upsFirmwareUpgradeEnd TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: UPS firmware update is over."
+ --#TYPE "UPS firmware update is over."
+ --#SUMMARY "UPS firmware update is over."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 57
+
+upsRFC1628TrapOnBattery TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: RFC1628: UPS is on battery."
+ --#TYPE "RFC1628: UPS is on battery."
+ --#SUMMARY "RFC1628: UPS is on battery."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 58
+
+upsRFC1628TrapTestCompleted TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: RFC1628: UPS test completed."
+ --#TYPE "RFC1628: UPS test completed."
+ --#SUMMARY "RFC1628: UPS test completed."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 59
+
+upsRFC1628TrapAlarmEntryAdded TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION "WARNING: RFC1628: Alarm entry added."
+ --#TYPE "RFC1628: Alarm entry added."
+ --#SUMMARY "RFC1628: Alarm entry added."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 60
+
+-- Misc. Traps
+failAuthViaHTTP TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Login authorization failure via HTTP."
+ --#TYPE "CPS: HTTP authorization failure."
+ --#SUMMARY "Login authorization failure via HTTP."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 61
+
+passwordChange TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: The password has been changed."
+ --#TYPE "CPS: Password changed."
+ --#SUMMARY "The password has been changed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 62
+
+failAuthViaConsole TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Login authorization failure via Console."
+ --#TYPE "CPS: HTTP authorization failure."
+ --#SUMMARY "Login authorization failure via Console."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 63
+
+configFileUpload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Configuration file uploaded."
+ --#TYPE "CPS: Configuration file uploaded."
+ --#SUMMARY "Configuration file uploaded."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 64
+
+adminLoginInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Administrator login."
+ --#TYPE "CPS: Administrator login information."
+ --#SUMMARY "Administrator login."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 65
+
+adminLogoutInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Administrator logout."
+ --#TYPE "CPS: Administrator logout information."
+ --#SUMMARY "Administrator logout."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 66
+
+deviceLoginInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Device login."
+ --#TYPE "CPS: Device user login information."
+ --#SUMMARY "Device user login from IP source."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 67
+
+deviceLogoutInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Device logout."
+ --#TYPE "CPS: Device user logout information."
+ --#SUMMARY "Device user logout from IP source."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 68
+
+configurationChanged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "INFORMATION: Configuration has been changed."
+ --#TYPE "CPS: Configuration changed."
+ --#SUMMARY "Configuration has been changed."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 69
+
+clientRegistered TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Information: PowerPanel client has been registered."
+ --#TYPE "CPS: PowerPanel client has been registered."
+ --#SUMMARY "PowerPanel client has been registered."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 70
+
+clientRemoved TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Information: PowerPanel client has been removed."
+ --#TYPE "CPS: Device user logout information."
+ --#SUMMARY "PowerPanel client has been registered."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 71
+
+testEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Information: Test Event."
+ --#TYPE "CPS: This is test message."
+ --#SUMMARY "This is test message."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 72
+
+outletUserLoginInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Information: Outlet User login."
+ --#TYPE "CPS: Outlet user login information."
+ --#SUMMARY "Outlet user login from IP source."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 73
+
+outletUserLogoutInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { mtrapinfoString }
+ DESCRIPTION
+ "Information: Outlet User logout."
+ --#TYPE "CPS: Outlet user logout information."
+ --#SUMMARY "Outlet user logout from IP source."
+ --#SEVERITY Information
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 74
+
+-- ePDU. Traps
+
+ePDUCommunicationEstablished TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication with a Rack PDU has been established.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Communication established."
+ --#SUMMARY "Communication with a Rack PDU established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 100
+
+ePDUCommunicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Communication with a Rack PDU has been lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Communication lost."
+ --#SUMMARY "Communication with a Rack PDU has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 101
+
+ePDUOutletOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has turned on.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "A Switched Rack PDU: An outlet has turned on."
+ --#SUMMARY "An outlet on a Switched Rack PDU has turned on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 102
+
+ePDUOutletOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has turned off.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "A Switched Rack PDU: An outlet has turned off."
+ --#SUMMARY "An outlet on a Switched Rack PDU has turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 103
+
+ePDUDeviceConfigChange TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made on a
+ Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "CPS Rack PDU: Device configuration change made."
+ --#SUMMARY "Device configuration change has been made on a Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 104
+
+ePDUOutletConfigChange TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet configuration change has been made on a
+ Switched Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS Switched Rack PDU: Outlet configuration change made."
+ --#SUMMARY "Outlet configuration change has been made on a Switched Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 105
+
+ePDULowLoad TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU has violated the low load threshold.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Violation of low load threshold."
+ --#SUMMARY "A Rack PDU has violated the low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 106
+
+ePDULowLoadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The low load condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Low load condition cleared."
+ --#SUMMARY "The low load condition on a Rack PDU has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 107
+
+ePDUNearOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU is near an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Near an overload condition."
+ --#SUMMARY "A Rack PDU is near an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 108
+
+ePDUNearOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The near overload condition on a Rack PDU has
+ been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Near overload condition has cleared."
+ --#SUMMARY "Rack PDU near overload condition has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 109
+
+ePDUOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: A Rack PDU is in an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Overload condition."
+ --#SUMMARY "A Rack PDU is in an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 110
+
+ePDUOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS Rack PDU: Overload condition has cleared."
+ --#SUMMARY "The overload condition on a Rack PDU has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 111
+
+ePDUDelayOutletOnCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn on.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "A Switched Rack PDU: An outlet has been assigned to turn on."
+ --#SUMMARY "An outlet on a Switched Rack PDU has been assigned to turn on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 112
+
+ePDUDelayOutletOffCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn off.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "A Switched Rack PDU: An outlet has been assigned to turn off."
+ --#SUMMARY "An outlet on a Switched Rack PDU has been assigned to turn off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 113
+
+ePDUDelayOutletRebootCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to reboot.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "A Switched Rack PDU: An outlet has been assigned to reboot."
+ --#SUMMARY "An outlet on a Switched Rack PDU has been assigned to reboot."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 114
+
+ePDUCancelPendingCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDUOutletControlIndex, ePDUOutletControlOutletName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A cancel pending command has been made on a
+ Switched Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number (0 indicates all outlets).
+ The fourth argument is the outlet name (or device name if all outlets)."
+ --#TYPE "A Switched Rack PDU: Cancel Pending Command made."
+ --#SUMMARY "A Cancel Pending Command has been made on a Switched Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 115
+
+
+ePDULineUndervoltage TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Utility Line Undervoltage
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "A Rack PDU: Utility Line Undervoltage."
+ --#SUMMARY "Utility Line Undervoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 116
+
+ePDULineUndervoltageCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility Line Undervoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "A Rack PDU: Utility Line Undervoltage Cleared."
+ --#SUMMARY "Utility Line Undervoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 117
+
+ePDULineOvervoltage TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Utility Line Overvoltage.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS PDU: Utility Line Overvoltage."
+ --#SUMMARY "Utility Line Overvoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 118
+
+ePDULineOvervoltageCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusPhaseNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility Line Overvoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "CPS PDU: Utility Line Overvoltage Cleared."
+ --#SUMMARY "Utility Line Overvoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 119
+
+
+ePDUPowerSupply1Fail TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Power Supply 1 on Rack PDU is in FAIL state.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Power Supply 1 is in FAIL state."
+ --#SUMMARY "Power Supply 1 on Rack PDU is in FAIL state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 120
+
+ePDUPowerSupply1Ok TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Power Supply 1 is operating normally."
+ --#SUMMARY "Power Supply 1 on Rack PDU is operating normally."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 121
+
+ePDUPowerSupply2Fail TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Power Supply 2 on Rack PDU is in FAIL state.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Power Supply 2 is in FAIL state."
+ --#SUMMARY "Power Supply 2 on Rack PDU is in FAIL state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 122
+
+ePDUPowerSupply2Ok TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "A Rack PDU: Power Supply 2 is operating normally."
+ --#SUMMARY "Power Supply 2 on Rack PDU is operating normally."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 123
+
+ePDUBankLowLoad TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU bank has violated the low load threshold.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number."
+ --#TYPE "CPS Rack PDU: Bank violation of low load threshold."
+ --#SUMMARY "A Rack PDU bank has violated the low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 124
+
+ePDUBankLowLoadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The low load condition on a Rack PDU bank has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number."
+ --#TYPE "CPS Rack PDU: Bank Low load condition cleared."
+ --#SUMMARY "The low load condition on a Rack PDU bank has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 125
+
+ePDUBankNearOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU bank is near an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number."
+ --#TYPE "CPS Rack PDU: Bank near an overload condition."
+ --#SUMMARY "A Rack PDU bank is near an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 126
+
+ePDUBankNearOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The near overload condition on a Rack PDU bank has
+ been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase/bank number."
+ --#TYPE "CPS Rack PDU: Bank near overload condition has cleared."
+ --#SUMMARY "Rack PDU bank near overload condition has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 127
+
+ePDUBankOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: A Rack PDU bank is in an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number."
+ --#TYPE "CPS Rack PDU: Bank overload condition."
+ --#SUMMARY "A Rack PDU bank is in an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 128
+
+ePDUBankOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ ePDULoadStatusBankNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition on a Rack PDU bank has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number."
+ --#TYPE "CPS Rack PDU: Bank overload condition has cleared."
+ --#SUMMARY "The bank overload condition on a Rack PDU has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 129
+
+ePDUComponentCommunicationEstablished TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Component communication lost has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "CPS Rack PDU: Component communication lost has been cleared."
+ --#SUMMARY "Component communication lost has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 130
+
+ePDUComponentCommunicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
+ mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: Component communication lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "CPS Rack PDU: Component communication lost."
+ --#SUMMARY "Component communication lost."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 131
+
+ePDUOutletLowLoad TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU has violated the outlet low load threshold.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 132
+
+ePDUOutletLowLoadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The outlet low load condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 133
+
+ePDUOutletNearOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: A Rack PDU is near an outlet overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 134
+
+ePDUOutletNearOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The outlet near overload condition on a Rack PDU has
+ been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 135
+
+ePDUOutletOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "SEVERE: A Rack PDU is in an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 136
+
+ePDUOutletOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
+ ePDUOutletConfigMonitoredName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The outlet overload condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name."
+ ::= 137
+
+-- Environment Traps
+envHighTemperatureViolation TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
+ DESCRIPTION
+ "WARNING: The environment high temperature threshold has been violated."
+ --#TYPE "CPS Environment Viewer: OverTemperature"
+ --#SUMMARY "The environment high temperature threshold has been violated."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 200
+
+envHighTemperatureBack TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
+ DESCRIPTION
+ "INFORMATION: The environment temperature returned from high value."
+ --#TYPE "CPS Environment Viewer: OverTemperature Returned"
+ --#SUMMARY "The environment temperature returned from high value."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 201
+
+envLowTemperatureViolation TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
+ DESCRIPTION
+ "WARNING: The environment low temperature threshold has been violated."
+ --#TYPE "CPS Environment Viewer: UnderTemperature"
+ --#SUMMARY "The environment low temperature threshold has been violated."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 202
+
+envLowTempBack TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
+ DESCRIPTION
+ "INFORMATION: The environment temperature returned from low value."
+ --#TYPE "CPS Environment Viewer: UnderTemperature Returned"
+ --#SUMMARY "The environment temperature returned from low value."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 203
+
+envHighHumidityViolation TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
+ DESCRIPTION
+ "WARNING: The environment high humidity threshold has been violated."
+ --#TYPE "CPS Environment Viewer: OverHumidity"
+ --#SUMMARY "The environment high humidity threshold has been violated."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 204
+
+envHighHumidityBack TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
+ DESCRIPTION
+ "INFORMATION: The environment humidity return from high value."
+ --#TYPE "CPS Environment Viewer: OverHumidity Returned"
+ --#SUMMARY "The environment humidity return from high value."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 205
+
+envLowHumidityViolation TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
+ DESCRIPTION
+ "WARNING: The environment low humidity threshold has been violated."
+ --#TYPE "CPS Environment Viewer: UnderHumidity"
+ --#SUMMARY "The environment low humidity threshold has been violated."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 206
+
+envLowHumdBack TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
+ DESCRIPTION
+ "INFORMATION: The environment humidity return from low value."
+ --#TYPE "CPS Environment Viewer: UnderHumidity Returned"
+ --#SUMMARY "The environment humidity return from low value."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 207
+
+envDryContactAbnormal TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation,
+ envirContactIndex, envirContactName }
+ DESCRIPTION
+ "INFORMATION: The Contact is abnormal."
+ --#TYPE "CPS Environment Viewer: Contact Abnormal"
+ --#SUMMARY "The Contact is abnormal."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 208
+
+envDryContactNormal TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation,
+ envirContactIndex, envirContactName }
+ DESCRIPTION
+ "INFORMATION: The Contact has returned from abnormal."
+ --#TYPE "CPS Environment Viewer: Contact Normal"
+ --#SUMMARY "The Contact has returned from abnormal."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 209
+
+envConntected TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation }
+ DESCRIPTION
+ "INFORMATION: The Environment Sensor has been connected."
+ --#TYPE "CPS Environment Viewer: The Environment Sensor has been connected"
+ --#SUMMARY "The Environment Sensor has been connected."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 210
+
+envDisconntected TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation }
+ DESCRIPTION
+ "INFORMATION: The Environment Sensor has been disconnected."
+ --#TYPE "CPS Environment Viewer: The Environment Sensor has been disconnected"
+ --#SUMMARY "The Environment Sensor has been disconnected."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 211
+
+envRateOfTemperatureChangeAbnormal TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
+ DESCRIPTION
+ "INFORMATION: The rate of temperature change is abnormal."
+ --#TYPE "CPS Environment Viewer: The rate of temperature change is abnormal"
+ --#SUMMARY "The rate of temperature change is abnormal."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 212
+
+envRateOfHumdChangeAbnormal TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
+ DESCRIPTION
+ "INFORMATION: The rate of humidity change is abnormal."
+ --#TYPE "CPS Environment Viewer: The rate of humidity change is abnormal"
+ --#SUMMARY "The rate of humidity change is abnormal."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 213
+
+atsSwitchSource TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusSelectedSource, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: ATS has switched source.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the selected source."
+ --#TYPE "CPS ATS: ATS has switched source."
+ --#SUMMARY "ATS has switched source."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 301
+
+atsSourceFault TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Source fault occurs.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name."
+ --#TYPE "CPS ATS: Source fault occurs."
+ --#SUMMARY "Source fault occurs."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 302
+
+atsSourceFaultCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Source fault has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name."
+ --#TYPE "CPS ATS: Source fault has been cleared."
+ --#SUMMARY "Source fault has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 303
+
+atsRedundancyFail TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Redundancy fails.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name."
+ --#TYPE "CPS ATS: Redundancy fails."
+ --#SUMMARY "Redundancy fails."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 304
+
+atsRedundancyRestored TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Redundancy has been restored.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name."
+ --#TYPE "CPS ATS: Redundancy has been restored."
+ --#SUMMARY "Redundancy has been restored."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 305
+
+atsInputHighVoltage TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The upper voltage limit has been crossed.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the phase voltage."
+ --#TYPE "CPS ATS: The upper voltage limit has been crossed."
+ --#SUMMARY "The upper voltage limit has been crossed."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 306
+
+atsInputHighVoltageCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The upper voltage condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the phase voltage."
+ --#TYPE "CPS ATS: The upper voltage condition has been cleared."
+ --#SUMMARY "The upper voltage condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 307
+
+atsInputLowVoltage TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The lower voltage limit has been crossed.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the phase voltage."
+ --#TYPE "CPS ATS: The lower voltage limit has been crossed."
+ --#SUMMARY "The lower voltage limit has been crossed."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 308
+
+atsInputLowVoltageCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The lower voltage condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the phase voltage."
+ --#TYPE "CPS ATS: The lower voltage condition has been cleared."
+ --#SUMMARY "The lower voltage condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 309
+
+atsInputHighFrequency TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The upper frequency limit has been crossed.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the input frequency."
+ --#TYPE "CPS ATS: The upper frequency limit has been crossed."
+ --#SUMMARY "The upper frequency limit has been crossed."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 310
+
+atsInputHighFrequencyCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The upper frequency condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the input frequency."
+ --#TYPE "CPS ATS: The upper frequency condition has been cleared."
+ --#SUMMARY "The upper frequency condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 311
+
+atsInputLowFrequency TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The lower frequency limit has been crossed.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the input frequency."
+ --#TYPE "CPS ATS: The lower frequency limit has been crossed."
+ --#SUMMARY "The lower frequency limit has been crossed."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 312
+
+atsInputLowFrequencyCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The lower frequency condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the source name.
+ The fourth argument is the input frequency."
+ --#TYPE "CPS ATS: The lower frequency condition has been cleared."
+ --#SUMMARY "The lower frequency condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 313
+
+atsCommunicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "MAJOR: ATS communication lost.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: ATS communication lost."
+ --#SUMMARY "ATS communication lost."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 314
+
+atsCommunicationEstablished TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: ATS communication has been established.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: ATS communication has been established."
+ --#SUMMARY "ATS communication has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 315
+
+atsLCDCommunicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: LCD communication lost.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: LCD communication lost."
+ --#SUMMARY "LCD communication lost."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 316
+
+atsLCDCommunicationLostCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: LCD communication lost has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: LCD communication lost has been cleared."
+ --#SUMMARY "LCD communication lost has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 317
+
+atsDB9CommunicationLost TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: DB9 communication lost.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: DB9 communication lost."
+ --#SUMMARY "DB9 communication lost."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 318
+
+atsDB9CommunicationLostCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: DB9 communication lost has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: DB9 communication lost has been cleared."
+ --#SUMMARY "DB9 communication lost has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 319
+
+atsPowerSupplyFault TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusPowerSupplyInputSource, mtrapinfoString }
+ DESCRIPTION
+ "CRITICAL: Power supply failure.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the input source of the power supply."
+ --#TYPE "CPS ATS: Power supply failure."
+ --#SUMMARY "Power supply failure."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 320
+
+atsPowerSupplyFaultCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusPowerSupplyInputSource, mtrapinfoString }
+ DESCRIPTION
+ "CRITICAL: Power supply failure.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the input source of the power supply."
+ --#TYPE "CPS ATS: Power supply failure has been cleared."
+ --#SUMMARY "Power supply failure has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 321
+
+atsDevHardwareFault TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "CRITICAL: Device hardware failure.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: Device hardware failure."
+ --#SUMMARY "Device hardware failure."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 322
+
+atsDevHardwareFaultCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Device hardware failure has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: Device hardware failure has been cleared."
+ --#SUMMARY "Device hardware failure has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 323
+
+atsSourceConfigChanged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A source configuration change has been made.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: A source configuration change has been made."
+ --#SUMMARY "A source configuration change has been made."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 324
+
+atsDeviceConfigChanged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: A device configuration change has been made."
+ --#SUMMARY "A device configuration change has been made."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 325
+
+atsOutletConfigChanged TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A outlet configuration change has been made.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: A outlet configuration change has been made."
+ --#SUMMARY "A outlet configuration change has been made."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 326
+
+atsEventCountsCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: Event counts has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number."
+ --#TYPE "CPS ATS: Event counts has been cleared."
+ --#SUMMARY "Event counts has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 327
+
+atsOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The load has exceeded overload threshold.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The load has exceeded overload threshold."
+ --#SUMMARY "The load has exceeded overload threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 328
+
+atsOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The overload condition has been cleared."
+ --#SUMMARY "The overload condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 329
+
+atsNearOverload TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The load has exceeded near overload threshold.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The load has exceeded near overload threshold."
+ --#SUMMARY "The load has exceeded near overload threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 330
+
+atsNearOverloadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The near overload condition has beed cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The near overload condition has beed cleared."
+ --#SUMMARY "The near overload condition has beed cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 331
+
+atsLowLoad TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: The load has been lower than low load threshold.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The load has been lower than low load threshold."
+ --#SUMMARY "The load has been lower than low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 332
+
+atsLowLoadCleared TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: The low load condition has been cleared.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the bank number.
+ The third argument is the load."
+ --#TYPE "CPS ATS: The low load condition has been cleared."
+ --#SUMMARY "The low load condition has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 333
+
+
+atsOutletOnCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on ATS has been assigned to turn on.
+ The first argument is the device name.
+ The second argument is the serial number.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS ATS: An outlet on ATS has been assigned to turn on."
+ --#SUMMARY "An outlet on ATS has been assigned to turn on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 334
+
+atsOutletOffCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on ATS has been assigned to turn off.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS ATS: An outlet on ATS has been assigned to turn off."
+ --#SUMMARY "An outlet on ATS has been assigned to turn off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 335
+
+atsOutletRebootCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on ATS has been assigned to reboot.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS ATS: An outlet on ATS has been assigned to reboot."
+ --#SUMMARY "An outlet on ATS has been assigned to reboot."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 336
+
+atsCancelPendingCommand TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A cancel pending command has been made on ATS.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number (0 indicates all outlets).
+ The fourth argument is the outlet name (or device name if all outlets)."
+ --#TYPE "CPS ATS: A cancel pending command has been made on ATS."
+ --#SUMMARY "A cancel pending command has been made on ATS."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 337
+
+atsOutletOn TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on ATS has turned on.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS ATS: An outlet on ATS has turned on."
+ --#SUMMARY "An outlet on ATS has turned on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 338
+
+atsOutletOff TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { atsIdentName, atsIdentSerialNumber,
+ atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on ATS has turned off.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "CPS ATS: An outlet on ATS has turned off."
+ --#SUMMARY "An outlet on ATS has turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 339
+
+-- ePDU2Traps
+pduDeviceEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2DeviceConfigIndex, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU device event has been happened.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the device table index."
+ ::= 400
+
+pduDeviceAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2DeviceStatusIndex, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU device alarm has been detected.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the device table index."
+ ::= 401
+
+pduDeviceAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2DeviceStatusIndex, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU device alarm has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the device table index."
+ ::= 402
+
+pduPhaseEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2PhaseConfigIndex, ePDU2PhaseConfigNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU phase event has been happened.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase table index.
+ The foutrh argument is the phase number."
+ ::= 403
+
+pduPhaseAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2PhaseStatusIndex, ePDU2PhaseStatusNumber, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU phase alarm has been detected.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase table index.
+ The foutrh argument is the phase number."
+ ::= 404
+
+pduPhaseAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2PhaseStatusIndex, ePDU2PhaseStatusNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU phase alarm has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase table index.
+ The foutrh argument is the phase number."
+ ::= 405
+
+pduBankEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2BankConfigIndex, ePDU2BankConfigNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU bank event has been happened.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank table index.
+ The foutrh argument is the bank number."
+ ::= 406
+
+pduBankAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2BankStatusIndex, ePDU2BankStatusNumber, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU bank alarm has been detected.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank table index.
+ The foutrh argument is the bank number."
+ ::= 407
+
+pduBankAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
+ ePDU2BankStatusIndex, ePDU2BankStatusNumber, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU bank alarm has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank table index.
+ The foutrh argument is the bank number."
+ ::= 408
+
+pduOutletSwitchedEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedControlIndex,
+ ePDU2OutletSwitchedControlNumber, ePDU2OutletSwitchedControlName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU switched outlet event has been happened.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 409
+
+pduOutletSwitchedAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedStatusIndex,
+ ePDU2OutletSwitchedStatusNumber, ePDU2OutletSwitchedStatusName, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU switched outlet alarm has been detected.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 410
+
+pduOutletSwitchedAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedStatusIndex,
+ ePDU2OutletSwitchedStatusNumber, ePDU2OutletSwitchedStatusName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU switched outlet alarm has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 411
+
+pduOutletMeteredEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredConfigIndex,
+ ePDU2OutletMeteredConfigNumber, ePDU2OutletMeteredConfigName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU metered outlet event has been happened.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 412
+
+pduOutletMeteredAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredStatusIndex,
+ ePDU2OutletMeteredStatusNumber, ePDU2OutletMeteredStatusName, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU metered outlet alarm has been detected.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 413
+
+pduOutletMeteredAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredStatusIndex,
+ ePDU2OutletMeteredStatusNumber, ePDU2OutletMeteredStatusName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU metered outlet alarm has been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet table index.
+ The foutrh argument is the outlet number.
+ The fifth argument is the outlet name."
+ ::= 414
+
+pduDaisyChainEvent TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
+ ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU daisy-chain event has been happened.
+ The first argument is the host serial number.
+ The second argument is the host device name.
+ The third argument is the event device table index.
+ The foutrh argument is the event device serial number.
+ The fifth argument is the event device name."
+ ::= 415
+
+pduDaisyChainAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
+ ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
+ DESCRIPTION
+ "Alarm: A PDU daisy-chain alarm has been detected.
+ The first argument is the host serial number.
+ The second argument is the host device name.
+ The third argument is the alarm device table index.
+ The foutrh argument is the alarm device serial number.
+ The fifth argument is the alarm device name."
+ ::= 416
+
+pduDaisyChainAlarmClear TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
+ ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU daisy-chain alarm has been cleared.
+ The first argument is the host serial number.
+ The second argument is the host device name.
+ The third argument is the alarm device table index.
+ The foutrh argument is the alarm deice serial number.
+ The fifth argument is the alarm device name."
+ ::= 417
+
+bmSystemAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "ALARM: System alarm occurance.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the alarm event specific identifier.
+ The fifth argument is the trap information string."
+ ::= 600
+
+bmSystemWarning TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: System warning occurance.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the alarm event specific identifier.
+ The fifth argument is the trap information string."
+ ::= 601
+
+bmSystemInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "INFO: System information.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the alarm event specific identifier.
+ The fifth argument is the trap information string."
+ ::= 602
+
+bmProbesAlarm TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "ALARM: Probe alarm event.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the string index the probe located.
+ The fifth argument is the battery index the probe located.
+ The sixth argument is the alarm event specific identifier.
+ The seventh argument is the trap information string."
+ ::= 603
+
+bmSProbesWarning TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "WARNING: Probe warning event.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the string index the probe located.
+ The fifth argument is the battery index the probe located.
+ The sixth argument is the alarm event specific identifier.
+ The seventh argument is the trap information string."
+ ::= 604
+
+bmProbesInfo TRAP-TYPE
+ ENTERPRISE cps
+ VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
+ DESCRIPTION
+ "INFO: Probe information.
+ The first argument is the bm device serial number.
+ The second argument is the bm system identification name.
+ The third argument is the bm system location.
+ The fourth argument is the string index the probe located.
+ The fifth argument is the battery index the probe located.
+ The sixth argument is the alarm event specific identifier.
+ The seventh argument is the trap information string."
+ ::= 605
+
+END
+