diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/comware/HH3C-USERLOG-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/comware/HH3C-USERLOG-MIB')
| -rw-r--r-- | MIBS/comware/HH3C-USERLOG-MIB | 805 |
1 files changed, 805 insertions, 0 deletions
diff --git a/MIBS/comware/HH3C-USERLOG-MIB b/MIBS/comware/HH3C-USERLOG-MIB new file mode 100644 index 0000000..8da7846 --- /dev/null +++ b/MIBS/comware/HH3C-USERLOG-MIB @@ -0,0 +1,805 @@ +-- ================================================================= +-- Copyright (C) 2003 New H3C Tech. Co., Ltd. All rights reserved. +-- +-- Description:This MIB file is used for management of userlog +-- information. +-- Reference: +-- Version: V1.1 +-- History: +-- V1.0 +-- 31st Mar 2003 +-- tianli, initial version +-- V1.1 2005-07-05 +-- Modify value range of hh3cUserlogNatAclNumber and hh3cUserlogFlowAclNumber +-- by tanbo02122. +-- Update file format by gaolong. +-- ================================================================= +HH3C-USERLOG-MIB DEFINITIONS ::= BEGIN + + IMPORTS + hh3cRhw + FROM HH3C-OID-MIB + OBJECT-GROUP, MODULE-COMPLIANCE + FROM SNMPv2-CONF + IpAddress, Integer32, Counter32, OBJECT-TYPE, + MODULE-IDENTITY + FROM SNMPv2-SMI; + + + hh3cUserLogMIB MODULE-IDENTITY + LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT + ORGANIZATION + "New H3C Tech. Co., Ltd." + CONTACT-INFO + "Platform Team New H3C Tech. Co., Ltd. + Hai-Dian District Beijing P.R. China + http://www.h3c.com + Zip:100085 + " + DESCRIPTION + "The HH3C-USERLOG-MIB contains objects to + Manage configuration and Monitor running state + for userlog feature." + ::= { hh3cRhw 18 } + + + hh3cUserlogObjects OBJECT IDENTIFIER ::= { hh3cUserLogMIB 1 } + + + hh3cUserlogNatObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 1 } + + + hh3cUserlogNatVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "NAT LOG version. Currently only version 1 is developed." + ::= { hh3cUserlogNatObjects 1 } + + + hh3cUserlogNatSyslog OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + NAT LOG format. + If 1, LOG format is sysLog. + If 0, LOG format is UDP packet. + UDP packet is the default format, and is recommended. + " + ::= { hh3cUserlogNatObjects 2 } + + + hh3cUserlogNatSourceIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Source IP address of NAT LOG UDP packet." + ::= { hh3cUserlogNatObjects 3 } + + + hh3cUserlogNatFlowBegin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Log the NAT flow when it is created. + If 1, this function is enabled. + If 0, this function is disabled. + This function will be used when real-time monitor required. + " + ::= { hh3cUserlogNatObjects 4 } + + + hh3cUserlogNatActiveTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The active time for long-time existed NAT flow. + Unit: minute. Range: 10 minutes ~ 120 minutes. + When setting it, NAT flow can be logged after an interval of + active time. + This function will be used when real-time monitor required. + The default value 0 means real-time monitor function is disabled. + " + ::= { hh3cUserlogNatObjects 5 } + + + hh3cUserlogNatSlotCfgInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogNatSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of NAT LOG configuration information for the + specified slot." + ::= { hh3cUserlogNatObjects 6 } + + + hh3cUserlogNatSlotCfgInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogNatSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "NAT LOG Configuration Information Entry for a slot." + INDEX { hh3cUserlogNatCfgSlotNumber } + ::= { hh3cUserlogNatSlotCfgInfoTable 1 } + + + Hh3cUserlogNatSlotCfgInfoEntry ::= + SEQUENCE { + hh3cUserlogNatCfgSlotNumber + Integer32, + hh3cUserlogNatEnable + Integer32, + hh3cUserlogNatAclNumber + Integer32, + hh3cUserlogNatHostAddress + IpAddress, + hh3cUserlogNatUdpPort + Integer32 + } + + hh3cUserlogNatCfgSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify which slot is configured with NAT LOG. " + ::= { hh3cUserlogNatSlotCfgInfoEntry 1 } + + + hh3cUserlogNatEnable OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The NAT LOG feature Enable status. + If 1, NAT LOG is enbled. + If 0, NAT LOG is disabled. + " + ::= { hh3cUserlogNatSlotCfgInfoEntry 2 } + + + hh3cUserlogNatAclNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Access-list number. + The value 0 means no ACL is specified. + Only when NAT LOG is enabled, can ACL be configured. + Only NAT flow which match the ACL will be logged. + " + ::= { hh3cUserlogNatSlotCfgInfoEntry 3 } + + + hh3cUserlogNatHostAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of NAT LOG server. " + ::= { hh3cUserlogNatSlotCfgInfoEntry 4 } + + + hh3cUserlogNatUdpPort OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP Port Number of NAT LOG UDP packet." + ::= { hh3cUserlogNatSlotCfgInfoEntry 5 } + + + hh3cUserlogNatSlotRunInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogNatSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of NAT LOG running information for the specified slot." + ::= { hh3cUserlogNatObjects 7 } + + + hh3cUserlogNatSlotRunInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogNatSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "NAT LOG Running Information Entry for a slot." + INDEX { hh3cUserlogNatRunSlotNumber } + ::= { hh3cUserlogNatSlotRunInfoTable 1 } + + + Hh3cUserlogNatSlotRunInfoEntry ::= + SEQUENCE { + hh3cUserlogNatRunSlotNumber + Integer32, + hh3cUserlogNatTotalEntries + Counter32, + hh3cUserlogNatTotalPackets + Counter32, + hh3cUserlogNatFailedEntries + Counter32, + hh3cUserlogNatFailedPackets + Counter32, + hh3cUserlogNatClearRunStat + Integer32 + } + + hh3cUserlogNatRunSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify on which slot the NAT LOG statistics + displayed." + ::= { hh3cUserlogNatSlotRunInfoEntry 1 } + + + hh3cUserlogNatTotalEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of NAT flow entries which are logged." + ::= { hh3cUserlogNatSlotRunInfoEntry 2 } + + + hh3cUserlogNatTotalPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of NAT LOG UDP packets generated by the router." + ::= { hh3cUserlogNatSlotRunInfoEntry 3 } + + + hh3cUserlogNatFailedEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of NAT flow entries failed in outputting." + ::= { hh3cUserlogNatSlotRunInfoEntry 4 } + + + hh3cUserlogNatFailedPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of NAT LOG UDP packets failed in outputting." + ::= { hh3cUserlogNatSlotRunInfoEntry 5 } + + + hh3cUserlogNatClearRunStat OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Clear the running statistics for NAT LOG. Write-only. + If 1, the running statistics for NAT LOG is resetted. + Other value is invalid. + " + ::= { hh3cUserlogNatSlotRunInfoEntry 6 } + + + hh3cUserlogFlowObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 2 } + + + hh3cUserlogFlowVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BAS FLOW LOG version. Currently only version 1 is developed." + ::= { hh3cUserlogFlowObjects 1 } + + + hh3cUserlogFlowSyslog OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + BAS FLOW LOG format. + If 1, LOG format is sysLog. + If 0, LOG format is UDP packet. + UDP packet is the default format, and is recommended. + " + ::= { hh3cUserlogFlowObjects 2 } + + + hh3cUserlogFlowSourceIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Source IP address of BAS FLOW LOG UDP packet." + ::= { hh3cUserlogFlowObjects 3 } + + + hh3cUserlogFlowFlowBegin OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Log the BAS flow when it is created. + If 1, this function is enabled. + If 0, this function is disabled. + This function will be used when real-time monitor required. + " + ::= { hh3cUserlogFlowObjects 4 } + + + hh3cUserlogFlowActiveTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The active time for long-time existed BAS flow. + Unit: minute. Range: 10 minutes ~ 120 minutes. + When setting it, BAS flow can be logged after an internal of + active time. + This function will be used when real-time monitor required. + The default value 0 means real-time monitor function is disabled. + " + ::= { hh3cUserlogFlowObjects 5 } + + + hh3cUserlogFlowSlotCfgInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogFlowSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of BAS FLOW LOG configuration information for the + specified slot." + ::= { hh3cUserlogFlowObjects 6 } + + + hh3cUserlogFlowSlotCfgInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogFlowSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "BAS FLOW LOG Configuration Information Entry for a slot." + INDEX { hh3cUserlogFlowCfgSlotNumber } + ::= { hh3cUserlogFlowSlotCfgInfoTable 1 } + + + Hh3cUserlogFlowSlotCfgInfoEntry ::= + SEQUENCE { + hh3cUserlogFlowCfgSlotNumber + Integer32, + hh3cUserlogFlowEnable + Integer32, + hh3cUserlogFlowAclNumber + Integer32, + hh3cUserlogFlowHostAddress + IpAddress, + hh3cUserlogFlowUdpPort + Integer32 + } + + hh3cUserlogFlowCfgSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify which slot is configured with BAS FLOW LOG." + ::= { hh3cUserlogFlowSlotCfgInfoEntry 1 } + + + hh3cUserlogFlowEnable OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The BAS FLOW LOG feature Enable status. + If 1, BAS FLOW LOG is enbled. + If 0, BAS FLOW LOG is disabled. + " + ::= { hh3cUserlogFlowSlotCfgInfoEntry 2 } + + + hh3cUserlogFlowAclNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Access-list number. + The value 0 means no ACL is specified. + Only when BAS FLOW LOG is enabled, can ACL be configured. + Only BAS flow which match the ACL will be logged. + " + ::= { hh3cUserlogFlowSlotCfgInfoEntry 3 } + + + hh3cUserlogFlowHostAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of BAS FLOW LOG server. " + ::= { hh3cUserlogFlowSlotCfgInfoEntry 4 } + + + hh3cUserlogFlowUdpPort OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP Port Number of BAS FLOW LOG UDP packet." + ::= { hh3cUserlogFlowSlotCfgInfoEntry 5 } + + + hh3cUserlogFlowSlotRunInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogFlowSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of BAS FLOW LOG running information for the specified slot." + ::= { hh3cUserlogFlowObjects 7 } + + + hh3cUserlogFlowSlotRunInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogFlowSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Running Information Entry for a slot." + INDEX { hh3cUserlogFlowRunSlotNumber } + ::= { hh3cUserlogFlowSlotRunInfoTable 1 } + + + Hh3cUserlogFlowSlotRunInfoEntry ::= + SEQUENCE { + hh3cUserlogFlowRunSlotNumber + Integer32, + hh3cUserlogFlowTotalEntries + Counter32, + hh3cUserlogFlowTotalPackets + Counter32, + hh3cUserlogFlowFailedEntries + Counter32, + hh3cUserlogFlowFailedPackets + Counter32, + hh3cUserlogFlowClearRunStat + Integer32 + } + + hh3cUserlogFlowRunSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify on which slot the BAS FLOW LOG + statistics displayed." + ::= { hh3cUserlogFlowSlotRunInfoEntry 1 } + + + hh3cUserlogFlowTotalEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS FLOW Entries which are logged." + ::= { hh3cUserlogFlowSlotRunInfoEntry 2 } + + + hh3cUserlogFlowTotalPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of FLOW LOG UDP packet generated by the router." + ::= { hh3cUserlogFlowSlotRunInfoEntry 3 } + + + hh3cUserlogFlowFailedEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS FLOW entries failed in outputting. " + ::= { hh3cUserlogFlowSlotRunInfoEntry 4 } + + + hh3cUserlogFlowFailedPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS FLOW LOG UDP packet failed in outputting." + ::= { hh3cUserlogFlowSlotRunInfoEntry 5 } + + + hh3cUserlogFlowClearRunStat OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Clear the running statistics for FLOW LOG. Write-only. + If 1, the running statistics for FLOW LOG is resetted. + Other value is invalid. + " + ::= { hh3cUserlogFlowSlotRunInfoEntry 6 } + + + hh3cUserlogAccessObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 3 } + + + hh3cUserlogAccessVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BAS ACCESS LOG version. Currently only version 1 is developed." + ::= { hh3cUserlogAccessObjects 1 } + + + hh3cUserlogAccessSyslog OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + BAS ACCESS LOG format. + If 1, LOG format is sysLog; + If 0, LOG format is UDP packet. + UDP packet is the default format, and is recommended. + " + ::= { hh3cUserlogAccessObjects 2 } + + + hh3cUserlogAccessSourceIP OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Source IP address of BAS ACCESS LOG UDP packet." + ::= { hh3cUserlogAccessObjects 3 } + + + hh3cUserlogAccessSlotCfgInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogAccessSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of BAS ACCESS LOG configuration information for the specified slot." + ::= { hh3cUserlogAccessObjects 4 } + + + hh3cUserlogAccessSlotCfgInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogAccessSlotCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "BAS ACCESS LOG Configuration Information Entry for a slot." + INDEX { hh3cUserlogAccessCfgSlotNumber } + ::= { hh3cUserlogAccessSlotCfgInfoTable 1 } + + + Hh3cUserlogAccessSlotCfgInfoEntry ::= + SEQUENCE { + hh3cUserlogAccessCfgSlotNumber + Integer32, + hh3cUserlogAccessEnable + Integer32, + hh3cUserlogAccessHostAddress + IpAddress, + hh3cUserlogAccessUdpPort + Integer32 + } + + hh3cUserlogAccessCfgSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify which slot is configured with BAS ACCESS LOG." + ::= { hh3cUserlogAccessSlotCfgInfoEntry 1 } + + + hh3cUserlogAccessEnable OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + The BAS ACCESS LOG feature Enable status. + If 1, BAS ACCESS LOG is enbled. + If 0, BAS ACCESS LOG is disabled. + " + ::= { hh3cUserlogAccessSlotCfgInfoEntry 2 } + + + hh3cUserlogAccessHostAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of BAS ACCESS LOG server." + ::= { hh3cUserlogAccessSlotCfgInfoEntry 3 } + + + hh3cUserlogAccessUdpPort OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP Port Number of BAS ACCESS LOG UDP packet." + ::= { hh3cUserlogAccessSlotCfgInfoEntry 4 } + + + hh3cUserlogAccessSlotRunInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cUserlogAccessSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of BAS ACCESS LOG running information for the specified slot." + ::= { hh3cUserlogAccessObjects 5 } + + + hh3cUserlogAccessSlotRunInfoEntry OBJECT-TYPE + SYNTAX Hh3cUserlogAccessSlotRunInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Running Information Entry for a slot." + INDEX { hh3cUserlogAccessRunSlotNumber } + ::= { hh3cUserlogAccessSlotRunInfoTable 1 } + + + Hh3cUserlogAccessSlotRunInfoEntry ::= + SEQUENCE { + hh3cUserlogAccessRunSlotNumber + Integer32, + hh3cUserlogAccessTotalEntries + Counter32, + hh3cUserlogAccessTotalPackets + Counter32, + hh3cUserlogAccessFailedEntries + Counter32, + hh3cUserlogAccessFailedPackets + Counter32, + hh3cUserlogAccessClearRunStat + Integer32 + } + + hh3cUserlogAccessRunSlotNumber OBJECT-TYPE + SYNTAX Integer32 (0..15) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed." + ::= { hh3cUserlogAccessSlotRunInfoEntry 1 } + + + hh3cUserlogAccessTotalEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS ACCESS Records which are logged." + ::= { hh3cUserlogAccessSlotRunInfoEntry 2 } + + + hh3cUserlogAccessTotalPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of ACCESS LOG UDP packet generated by the router." + ::= { hh3cUserlogAccessSlotRunInfoEntry 3 } + + + hh3cUserlogAccessFailedEntries OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS ACCESS entries failed in outputting." + ::= { hh3cUserlogAccessSlotRunInfoEntry 4 } + + + hh3cUserlogAccessFailedPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of BAS ACCESS LOG UDP packet failed in outputting." + ::= { hh3cUserlogAccessSlotRunInfoEntry 5 } + + + hh3cUserlogAccessClearRunStat OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + Clear the running statistics for ACCESS LOG. Write-only. + If 1, the running statistics for ACCESS LOG is resetted. + Other value is invalid. + " + ::= { hh3cUserlogAccessSlotRunInfoEntry 6 } + + + hh3cUserlogNotifications OBJECT IDENTIFIER ::= { hh3cUserLogMIB 2 } + + + hh3cUserlogConformance OBJECT IDENTIFIER ::= { hh3cUserLogMIB 3 } + + + hh3cUserlogCompliances OBJECT IDENTIFIER ::= { hh3cUserlogConformance 1 } + + + hh3cUserlogCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement the + Userlog mib." + MODULE -- this module + MANDATORY-GROUPS { hh3cUserlogMandatoryGroup } + ::= { hh3cUserlogCompliances 1 } + + + hh3cUserlogGroups OBJECT IDENTIFIER ::= { hh3cUserlogConformance 2 } + + + hh3cUserlogMandatoryGroup OBJECT-GROUP + OBJECTS { hh3cUserlogNatEnable, hh3cUserlogNatHostAddress, hh3cUserlogNatUdpPort, + hh3cUserlogFlowEnable, hh3cUserlogFlowHostAddress, hh3cUserlogFlowUdpPort, + hh3cUserlogAccessEnable, hh3cUserlogAccessHostAddress, hh3cUserlogAccessUdpPort + } + STATUS current + DESCRIPTION + "A collection of objects providing mandatory Userlog information." + ::= { hh3cUserlogGroups 1 } + + + hh3cUserlogConfigGroup OBJECT-GROUP + OBJECTS { hh3cUserlogNatVersion, hh3cUserlogNatSyslog, hh3cUserlogNatSourceIP, + hh3cUserlogNatFlowBegin, hh3cUserlogNatActiveTime, hh3cUserlogNatCfgSlotNumber, + hh3cUserlogNatEnable, hh3cUserlogNatAclNumber, hh3cUserlogNatHostAddress, + hh3cUserlogNatUdpPort, hh3cUserlogFlowVersion, hh3cUserlogFlowSyslog, + hh3cUserlogFlowSourceIP, hh3cUserlogFlowFlowBegin, hh3cUserlogFlowActiveTime, + hh3cUserlogFlowCfgSlotNumber, hh3cUserlogFlowEnable, hh3cUserlogFlowAclNumber, + hh3cUserlogFlowHostAddress, hh3cUserlogFlowUdpPort, hh3cUserlogAccessVersion, + hh3cUserlogAccessSyslog, hh3cUserlogAccessSourceIP, hh3cUserlogAccessCfgSlotNumber, + hh3cUserlogAccessEnable, hh3cUserlogAccessHostAddress, hh3cUserlogAccessUdpPort + } + STATUS current + DESCRIPTION + "All configurable parameters of Userlog feature." + ::= { hh3cUserlogGroups 2 } + + + hh3cUserlogInfoGroup OBJECT-GROUP + OBJECTS { hh3cUserlogNatTotalEntries, hh3cUserlogNatTotalPackets, + hh3cUserlogNatFailedEntries, hh3cUserlogNatFailedPackets, + hh3cUserlogFlowTotalEntries, hh3cUserlogFlowTotalPackets, + hh3cUserlogFlowFailedEntries, hh3cUserlogFlowFailedPackets, + hh3cUserlogAccessTotalEntries, hh3cUserlogAccessTotalPackets, + hh3cUserlogAccessFailedEntries, hh3cUserlogAccessFailedPackets + } + STATUS current + DESCRIPTION + "All running information of Userlog feature." + ::= { hh3cUserlogGroups 3 } + +END |