diff --git a/MIBS/comware/HH3C-POWER-ETH-EXT-MIB b/MIBS/comware/HH3C-POWER-ETH-EXT-MIB new file mode 100644 index 0000000..c6aad9b --- /dev/null +++ b/MIBS/comware/HH3C-POWER-ETH-EXT-MIB @@ -0,0 +1,1610 @@ +-- ================================================================= +-- Copyright (c) 2004-2019 New H3C Tech. Co., Ltd. All rights reserved. +-- +-- Description: Power over ethernet extend MIB +-- Reference: POWER-ETHERNET-MIB +-- Version: V1.7 +-- History: +-- V1.0 2004-07-24 Created by Gaolong +-- V1.1 2004-09-08 Update file by Gaolong for some syntax errors. +-- V1.2 2004-11-19 Update file by liuhongxu for poe need. +-- add hh3cMainPsePriorityMode¡¢hh3cPsePowerMaxValue¡¢ +-- hh3cpsePDChangNotification adjust the objects' sequence of +-- hh3cPsePortTable and hh3cMainPseTable add the description +-- of MANDATORY-GROUPS in hh3cPseCompliance. +-- V1.3 2004-12-16 Update file by liuhongxu for poe profile +-- add hh3cPsePortProfile, hh3cPseProfilesTable +-- change the name of hh3cPseProfileIndex add +-- hh3cPseProfileApplyNum. adjust the format of this mib. +-- V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need. +-- add hh3cPOEPowerObjects, hh3cPOEThresholdLimitObjs, +-- hh3cPOESupModuleInfoObjs, hh3cPOEDCOutStateObjects, +-- hh3cPOEDCDCOutInfoObjects, hh3cPOEACSwitchStateModuleObjs, +-- hh3cPOEInCurStateObjects, hh3cPOEAlarmStateObjects and the +-- sub-nodes. add 17 traps change the node name from +-- hh3cpsePDChangNotification to hh3cpsePDChangeNotification +-- change some detail as the suggestion from Wangyingxia and +-- Yangyang. adjust the format of this mib. +-- V1.5 2005-11-21 Update file by Liweizhen for controling the power-management +-- policy of PSE or PD. Add hh3cPsePolicyMode, hh3cPDPolicyMode, +-- hh3cMainPsePowerPriority. +-- Delete some description of hh3cPsePortProfileIndex node. +-- Change the description of hh3cPseProfilePowerMode node. +-- Change SYNTAX OCTET STRING range for the following nodes: +-- hh3cPOEPowerType, hh3cPOESupervisionModuleName, +-- hh3cPOESMFactorName, hh3cPOEModuleHardVerInfo. +-- Adjust the format of this mib. +-- V1.6 2015-07-21 Update file by Fangliwen for profile power limit. +-- Change the syntax of hh3cPseProfilePowerLimit node. +-- V1.7 2019-5-23 Update file for PoE-AI. Add the following nodes: +-- hh3cPsePDDisableNotification,hh3cPsePortGroupIndex, +-- hh3cPsePortIndex and hh3cPsePortDisableInfo. +-- ================================================================= +HH3C-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN + +IMPORTS + hh3cCommon + FROM HH3C-OID-MIB + pethPsePortGroupIndex, pethPsePortIndex, + pethMainPseGroupIndex, pethPsePortDetectionStatus + FROM POWER-ETHERNET-MIB + OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP + FROM SNMPv2-CONF + Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE + FROM SNMPv2-SMI + DisplayString, RowStatus, TEXTUAL-CONVENTION + FROM SNMPv2-TC; + + +hh3cPowerEthernetExt MODULE-IDENTITY + LAST-UPDATED "201905230000Z" -- May 23, 2019 at 00:00 GMT + + ORGANIZATION + "New H3C Tech. Co., Ltd." + CONTACT-INFO + "Platform Team New H3C Tech. Co., Ltd. + Hai-Dian District Beijing P.R. China + http://www.h3c.com + Zip:100085 + " + DESCRIPTION + "Description." + REVISION "201905230000Z" + DESCRIPTION + "Add the following nodes: + hh3cPsePDDisableNotification,hh3cPsePortGroupIndex, + hh3cPsePortIndex and hh3cPsePortDisableInfo." + REVISION "201507250000Z" + DESCRIPTION + "The initial version of this MIB module." + ::= { hh3cCommon 14 } + + +-- +-- Node definitions +-- + +hh3cPsePortTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The indexing scheme is taken form that used by + the IETF Power MIB. The same indexing scheme is + used to give continuity in behaviour between + that standard and this extensions definitioin." + ::= { hh3cPowerEthernetExt 1 } + + +hh3cPsePortEntry OBJECT-TYPE + SYNTAX Hh3cPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The pethPsePortGroupIndex is imported from the IETF Power MIB + and uniquely identifies the group containing the port to which + power ethernet PSE is connected. Group means (box in the stack, + module in a rack). + + The pethPsePortPowerIndex is imported from the IETF Power MIB + and uniquely identifies the power ethernet PSE port within group + pethPseGroupIndex to which the power Ethernet PSE entry is + connected. This value will match the local port number on a + switch." + INDEX { pethPsePortGroupIndex, pethPsePortIndex } + ::= { hh3cPsePortTable 1 } + + +Hh3cPsePortEntry ::= + SEQUENCE { + hh3cPsePortFaultDescription + DisplayString, + hh3cPsePortPeakPower + Integer32, + hh3cPsePortAveragePower + Integer32, + hh3cPsePortCurrentPower + Integer32, + hh3cPsePortPowerLimit + Integer32, + hh3cPsePortProfileIndex + Integer32 + } + +hh3cPsePortFaultDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object supports the fault category of the IETF Power MIB [1] + pethPsePortDetectionStatus object. A textual description + containing more information about the nature of this fault is + provided by this object. Typically this will detail the precise + PoE hardware state which is causing the pethPsePortDetectionStatus + object to be in the 'fault' state. + It is a DisplayString of up to 255 characters." + ::= { hh3cPsePortEntry 2 } + + +hh3cPsePortPeakPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the peak power which has been consumed by + the port. It is defined as the highest measured value of power + in milliWatts that has been consumed by the port. Its value + is only reset when link is lost, the port is PoE disabled or + when it is manually reset by the user asspecified below. + It is a read/write integer value with units of milliWatts. + Writing a value of zero to this object resets its value + to zero. Writing any other value to this object has no + effect on its value and an error is returned." + ::= { hh3cPsePortEntry 3 } + + +hh3cPsePortAveragePower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the average power which has been consumed + by the port. This object is a read/write integer value with + units of milliWatts. Writing a value of zero to this object + resets its value to zero. Writing any other value to this + object has no effect on its value and an error is returned." + ::= { hh3cPsePortEntry 4 } + + +hh3cPsePortCurrentPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the power currently being consumed by the port. + It is a read only integer value with units of milliWatts." + ::= { hh3cPsePortEntry 5 } + + +hh3cPsePortPowerLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the power limit set for this port. + The PSE will not supply more than this level of power to the + specified port. + It is a read/write integer value with units of milliWatts." + ::= { hh3cPsePortEntry 6 } + +hh3cPsePortProfileIndex OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates the power profile which is currently associated + with this port. This object references the corresponding + hh3cPseProfileIndex object in the power profiles table. A + value of zero is a special case and indicates that no + power profile is currently associated with this port. When + hh3cPseProfileIndex is set to an index of existent profile, + pethPsePortPowerPairs, pethPsePortPowerPriority, + pethPsePortAdminEnable and hh3cPsePortPowerLimit will be + set to the same as corresponding value. PethPsePortPowerPairs, + pethPsePortPowerPriority and pethPsePortAdminEnable are objects + of rfc3621-Power-Ethernet.mib." + ::= { hh3cPsePortEntry 7 } + + +hh3cMainPseTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Description." + ::= { hh3cPowerEthernetExt 2 } + + +hh3cMainPseEntry OBJECT-TYPE + SYNTAX Hh3cMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The pethMainPseGroupIndex is imported from the IETF Power MIB + and uniquely identifies the group containing the port to which + power ethernet PSE is connected. Group means (box in the stack, + module in a rack) and the value 1 MUST be used for non-modular + devices." + INDEX { pethMainPseGroupIndex } + ::= { hh3cMainPseTable 1 } + + +Hh3cMainPseEntry ::= + SEQUENCE { + hh3cMainPsePowerLimit + Integer32, + hh3cMainPseAveragePower + Integer32, + hh3cMainPsePeakPower + Integer32, + hh3cMainGuaranteedPowerRemaining + Integer32, + hh3cMainPsePriorityMode + INTEGER, + hh3cMainPseLegacy + INTEGER, + hh3cMainPsePowerPriority + INTEGER + } + +hh3cMainPsePowerLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the power limit set for the unit as a whole. + The PoE unit will already have a nominal power defined by the + IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object + specifies a further limit to this nominal power value. This may + be useful to control the thermals of the unit, or for internal + testing purposes. One possible use for this object may be to lower + the power consumption of the unit if one or more of the internal + fans have broken. It is a read/write integer value with units of + Watts (note - Watts is chosen instead of milliWatts here since + the IETF Power MIB [1] measures unit based parameters, such as + the pethMainPsePower object, in units of Watts)." + ::= { hh3cMainPseEntry 1 } + + +hh3cMainPseAveragePower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the average power which has been consumed + by the port. It is a read/write integer value with units of + Watts (note - Watts is chosen instead of milliWatts here since + the IETF Power MIB [1] measures unit based parameters, such as + the pethMainPsePower object, in units of Watts). Writing a value + of zero to this object resets its value to zero. Writing any + other value to this object has no effect on its value and an error + is returned." + ::= { hh3cMainPseEntry 2 } + + +hh3cMainPsePeakPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the peak power which has been consumed for PoE. + It is defined as the highest measured value of power in milliWatts + that has been consumed at any one point in time by the sum of the PoE + ports. Its value is only reset when the unit is powered on or when + it is manually reset by the user as specifiedbelow. It is a read/write + integer value with units of Watts (note - Watts is chosen instead of + milliWatts here since the IETF Power MIB [1] measures unit based + parameters, such as the pethMainPsePower object, in units of Watts). + Writing a value of zero to this object resets its value to zero. + Writing any other value to this object has noeffect on its value + and an error is returned." + ::= { hh3cMainPseEntry 3 } + + +hh3cMainGuaranteedPowerRemaining OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the amount of power remaining in the guaranteed + power pool. Each time a port is placed into guaranteed mode it + reserves a set amount of power out of the total guaranteed power + pool for the system. This intention of this object is to give the + client of this MIB (whether that be the CLI or the Web interface or + the end user) an indication of how many ports can still be placed + into guaranteed mode. It is a read only integer value with units of + Watts(note - Watts is chosen instead of milliWatts here since the + IETF Power MIB [1] measures unit based parameters,such as the + pethMainPsePower object, in units of Watts)." + ::= { hh3cMainPseEntry 4 } + + +hh3cMainPsePriorityMode OBJECT-TYPE + SYNTAX INTEGER { + disconnection(0), + non-disconnection(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes or controls the priority mode on slot which must be + enabled firstly. When a new board is inserted, and the power is + over-load, a value of disconnection(0) means that the power will + stop supply to the low priority slot ; A value of non-disconnection(1) + means that the slot still supply when a new board is inserted, and + the power is over-load too." + ::= { hh3cMainPseEntry 5 } + +hh3cMainPseLegacy OBJECT-TYPE + SYNTAX INTEGER { + enable(0), + disable(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes or controls the legacy mode on slot which must be enabled + firstly. Legacy mode: standard or nonstandard PD detection mode." + ::= { hh3cMainPseEntry 6 } + +hh3cMainPsePowerPriority OBJECT-TYPE + SYNTAX INTEGER { + critical(1), + high(2), + low(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes or controls the priority of the PSE. The priority + will be used by the PSE policy to prevent from power overloading. + If the priority of PSE is set to critical, the PSE will turn into + guaranteed mode. The priority could be used by a control mechanism + that prevents power overloading by disconnecting PSEs with lower + power priority. PSEs that connect devices critical to the + application should be set to higher priority." + ::= { hh3cMainPseEntry 7 } + +-- Power Profile PSE table +hh3cPseProfilesTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPseProfilesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of objects representing a set of power profiles. + Power profiles can be applied to PoE ports, which have the + effect of automatically setting the priority, power limit + and PoE enable MIB objects to the values specified in the + power profile." + ::= { hh3cPowerEthernetExt 7 } + +hh3cPseProfilesEntry OBJECT-TYPE + SYNTAX Hh3cPseProfilesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of objects that display and control the Main power of a PSE." + INDEX { hh3cPseProfileIndex } + ::= { hh3cPseProfilesTable 1 } + +Hh3cPseProfilesEntry ::= SEQUENCE { + hh3cPseProfileIndex Integer32, + hh3cPseProfileName DisplayString, + hh3cPseProfilePowerMode INTEGER, + hh3cPseProfilePowerLimit Integer32, + hh3cPseProfilePriority INTEGER, + hh3cPseProfilePairs INTEGER, + hh3cPseProfileApplyNum Integer32, + hh3cPseProfileRowStatus RowStatus + } + +hh3cPseProfileIndex OBJECT-TYPE + SYNTAX Integer32 (1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the profile. This uniquely allow the profile to be + identified." + ::= { hh3cPseProfilesEntry 1 } + +hh3cPseProfileName OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Assigns the profile a name with which the settings + can be assiciated with. For example, 'NBX Phone'." + ::= { hh3cPseProfilesEntry 2 } + +hh3cPseProfilePowerMode OBJECT-TYPE + SYNTAX INTEGER { + powerDisabled (1), + powerEnabled (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The power mode associated with this power profile. There + are two possible power modes as follows: powerDisabled, + powerEnabled. When a power profile is applied to a PSE port, + this value dictates the settings of the ports pethPsePortPowerPriority + and pethPsePortAdminEnable objects." + ::= { hh3cPseProfilesEntry 3 } + +hh3cPseProfilePowerLimit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The power limit to be applied to the ports hh3cPsePortPowerLimit + object when the profile is applied to the PSE port. Expressed in + milliWatts." + ::= { hh3cPseProfilesEntry 4 } + +hh3cPseProfilePriority OBJECT-TYPE + SYNTAX INTEGER { + critical(1), + high(2), + low(3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the priority of the port from the point of + view of a power management algorithm. The priority that is set + by this variable could be used by a control mechanism that + prevents over current situations by disconnecting first ports + with lower power priority. Ports that connect devices critical + to the operation of the network - like the E911 telephones + ports - should be set to higher priority." + ::= { hh3cPseProfilesEntry 5 } + +hh3cPseProfilePairs OBJECT-TYPE + SYNTAX INTEGER { + signal(1), + spare(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Describes or controls the pairs in use. If the value of + pethPsePortPowerPairsControl is true, this object is writable. + A value of signal(1) means that the signal pairs only are in use. + A value of spare(2) means that the spare pairs only are in use." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs" + ::= { hh3cPseProfilesEntry 6 } + +hh3cPseProfileApplyNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of this profile which has been applied. + If hh3cPseProfileApplyNum is not zero, user can't + change the current line." + ::= { hh3cPseProfilesEntry 7 } + +hh3cPseProfileRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this classifier. + If hh3cPseProfileApplyNum is not zero, user can't + delete the current line." + ::= { hh3cPseProfilesEntry 8 } + +hh3cPseAutoDetectActive OBJECT-TYPE + SYNTAX INTEGER + { + notSupported(1), + disabled(2), + enabled(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies whether the device auto-detection feature is + active. If this object is set to Active, and a known powered device + is detected, then the port will automatically switch to Auto-Guaranteed + mode. This is a stackwide object (ie. it is not referenced by + group index)." + ::= { hh3cPowerEthernetExt 3 } + +hh3cPsePowerMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object specifies the max poe power for lanswitch. + The value should between the power currently and the max power." + ::= { hh3cPowerEthernetExt 5 } + +hh3cPsePolicyMode OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + priority(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The PSE policy only applies to the situation that when a new + board (PSE) is inserted, and the power is overload. + A value of priority(2) means that the power will stop supplying + to the low priority PSE. About PSE priority, please refer to + hh3cMainPsePowerPriority. A value of disabled(1) means that the + power will stop supplying to the new inserted PSE. The default + value of this object is disabled(1)." + ::= { hh3cPowerEthernetExt 9 } + +hh3cPDPolicyMode OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + priority(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The PD policy only applies to the situation that when a new + PD is inserted, and the power of PSE is overload. + A value of priority(2) means that the power will stop supplying + to the low priority port PD. About port priority, please refer + to pethPsePortPowerPriority. A value of disabled(1) means that + the slot stop supplying to the new inserted PD. The default + value of this object is disabled(1)." + ::= { hh3cPowerEthernetExt 10 } + +hh3cpseportNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 6 } + +-- Notification Control Objects + +hh3cpsePDChangeNotification NOTIFICATION-TYPE + OBJECTS { pethPsePortDetectionStatus } + STATUS current + DESCRIPTION + "This notification indicates if PD has been inserted or pulled out." + ::= { hh3cpseportNotification 1 } + +hh3cPOEDisconnectNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleDisconnect } + STATUS current + DESCRIPTION + "This notification indicates the POE power module does not disconnect." + ::= { hh3cpseportNotification 2 } + +hh3cPOEInputErrorNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleInputError } + STATUS current + DESCRIPTION + "This notification indicates the POE power module input error." + ::= { hh3cpseportNotification 3 } + +hh3cPOEOutputErrorNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOutputError } + STATUS current + DESCRIPTION + "This notification indicates the POE power module output error." + ::= { hh3cpseportNotification 4 } + +hh3cPOEOverVoltageNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverVoltage } + STATUS current + DESCRIPTION + "This notification indicates the POE power module overruns the + voltage limit." + ::= { hh3cpseportNotification 5 } + +hh3cPOEOverTempNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverTemp } + STATUS current + DESCRIPTION + "This notification indicates the POE power module overruns the + temperature limit." + ::= { hh3cpseportNotification 6 } + +hh3cPOEFanErrorNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleFanError } + STATUS current + DESCRIPTION + "This notification indicates the POE power module fan error." + ::= { hh3cpseportNotification 7 } + +hh3cPOEModuleShutdownNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleShutdown } + STATUS current + DESCRIPTION + "This notification indicates the POE power module is closed." + ::= { hh3cpseportNotification 8 } + +hh3cPOECurRestrictedNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleCurRestricted } + STATUS current + DESCRIPTION + "This notification indicates the POE power module current is restricted." + ::= { hh3cpseportNotification 9 } + +hh3cPOEACSwitchNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEACSwitchStateIndex, hh3cPOEACSwitchState } + STATUS current + DESCRIPTION + "This notification indicates the AC input switch alarm of this POE power." + ::= { hh3cpseportNotification 10 } + +hh3cPOEACInCurANotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEInCurAState } + STATUS current + DESCRIPTION + "This notification indicates the AC input current A alarm state of + this POE power." + ::= { hh3cpseportNotification 11 } + +hh3cPOEACInCurBNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEInCurBState } + STATUS current + DESCRIPTION + "This notification indicates the AC input current B alarm state of + this POE power." + ::= { hh3cpseportNotification 12 } + +hh3cPOEACInCurCNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEInCurCState } + STATUS current + DESCRIPTION + "This notification indicates the AC input current C alarm state of + this POE power." + ::= { hh3cpseportNotification 13 } + +hh3cPOEACSwitchVolABNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolAB} + STATUS current + DESCRIPTION + "This notification indicates the AC input voltage AB alarm state of + this POE power." + ::= { hh3cpseportNotification 14 } + +hh3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolBC} + STATUS current + DESCRIPTION + "This notification indicates the AC input voltage BC alarm state of + this POE power." + ::= { hh3cpseportNotification 15 } + +hh3cPOEACSwitchVolCANotification NOTIFICATION-TYPE + OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolCA } + STATUS current + DESCRIPTION + "This notification indicates the AC input voltage CA alarm state of + this POE power." + ::= { hh3cpseportNotification 16 } + +hh3cPOEDCOutVolNotification NOTIFICATION-TYPE + OBJECTS { hh3cPOEDCOutStateIndex, hh3cPOEDCOutDCVolAlarm } + STATUS current + DESCRIPTION + "This notification indicates the DC output alarm of this POE power." + ::= { hh3cpseportNotification 17 } + +hh3cPOEShutdownNotification NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "This notification indicates the whole POE power has been shutdown." + ::= { hh3cpseportNotification 18 } +hh3cPseComformance OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 4 } + +hh3cPseCompliances OBJECT IDENTIFIER ::= { hh3cPseComformance 1 } + +hh3cPseCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Description." + MODULE -- this module + MANDATORY-GROUPS { hh3cPsePortGroup, + hh3cMainPseGroup, + hh3cPseScalarGroup, + hh3cPsePDNotificationGroup + } + GROUP hh3cPseProfilesGroup + DESCRIPTION + "This group is mandatory only for executing POE commands as a batch." + ::= { hh3cPseCompliances 1 } + +hh3cPseGroup OBJECT IDENTIFIER ::= { hh3cPseComformance 2 } + +hh3cPsePortGroup OBJECT-GROUP + OBJECTS { hh3cPsePortProfileIndex, hh3cPsePortPowerLimit, hh3cPsePortCurrentPower, + hh3cPsePortAveragePower, hh3cPsePortPeakPower, hh3cPsePortFaultDescription, + hh3cMainPsePriorityMode + } + STATUS current + DESCRIPTION + "A collection of objects should be supported at the same time." + ::= { hh3cPseGroup 1 } + +hh3cMainPseGroup OBJECT-GROUP + OBJECTS { hh3cMainPsePowerLimit, hh3cMainPseAveragePower, hh3cMainPsePeakPower, + hh3cMainGuaranteedPowerRemaining } + STATUS current + DESCRIPTION + "A collection of objects should be supported at the same time." + ::= { hh3cPseGroup 2 } + +hh3cPseScalarGroup OBJECT-GROUP + OBJECTS { hh3cPseAutoDetectActive, hh3cPsePowerMaxValue, hh3cPsePolicyMode , + hh3cPDPolicyMode } + STATUS current + DESCRIPTION + "A collection of scalar objects supported." + ::= { hh3cPseGroup 3 } + +hh3cPsePDNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { hh3cpsePDChangeNotification } + STATUS current + DESCRIPTION + "PD Change Notification." + ::= { hh3cPseGroup 4 } + +hh3cPseProfilesGroup OBJECT-GROUP + OBJECTS { hh3cPseProfileName, hh3cPseProfilePowerMode, + hh3cPseProfilePowerLimit, hh3cPseProfilePriority, + hh3cPseProfilePairs, hh3cPseProfileApplyNum, hh3cPseProfileRowStatus} + STATUS current + DESCRIPTION + "A collection of objects should be supported at the same time." + ::= { hh3cPseGroup 5 } + +hh3cPOEPowerThresholdLimitGroup OBJECT-GROUP + OBJECTS { hh3cPOEThresholdACMimimum, hh3cPOEThresholdACMaximum, + hh3cPOEThresholdDCMinimum, hh3cPOEThresholdDCMaximum } + STATUS current + DESCRIPTION + "Power threshold limits group." + ::= { hh3cPseGroup 6 } + +hh3cPOEPowerSupInfoGroup OBJECT-GROUP + OBJECTS { hh3cPOEPowerType, hh3cPOEPowerModuleNum, hh3cPOESupervisionModuleName, + hh3cPOESMMajorVersion, hh3cPOESMMinorVersion, hh3cPOESMFactorName} + STATUS current + DESCRIPTION + "The basic Power information group." + ::= { hh3cPseGroup 7 } + +hh3cPOEPowerDCOutStateGroup OBJECT-GROUP + OBJECTS { hh3cPOEDCOutStateModuleNum } + STATUS current + DESCRIPTION + "The DC out power state group." + ::= { hh3cPseGroup 8 } + +hh3cPOEPowerDCOutInfoGroup OBJECT-GROUP + OBJECTS { hh3cPOEDCOutCurNum } + STATUS current + DESCRIPTION + "The power AC input switch information group" + ::= { hh3cPseGroup 9 } + +hh3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP + OBJECTS { hh3cPOEACSwitchStateModuleNum} + STATUS current + DESCRIPTION + "PD Change Notification." + ::= { hh3cPseGroup 10 } + +hh3cPOEPowerInCurStateGroup OBJECT-GROUP + OBJECTS { hh3cPOEInCurStateModuleNum, hh3cPOEInCurAState, hh3cPOEInCurBState, + hh3cPOEInCurCState} + STATUS current + DESCRIPTION + "PD Change Notification." + ::= { hh3cPseGroup 11 } + +hh3cPOEPowerAlarmStateGroup OBJECT-GROUP + OBJECTS { hh3cPOEAlarmStateModuleNum } + STATUS current + DESCRIPTION + "PD Change Notification." + ::= { hh3cPseGroup 12 } + +ACAlarmState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "AC Alarm State." + SYNTAX INTEGER{ + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7) + } + +DCAlarmState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "DC Alarm State." + SYNTAX INTEGER{ + normal (1), + underLimit (2), + aboveLimit (3), + fuseBroken (4), + switchOff (5), + otherError (6) + } + +SwitchState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Switch State." +SYNTAX INTEGER { + on (1), + off (2), + highVoltInput (3), + lowVoltInput (4) + } + +ModuleAlarmState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Module Alarm State." + SYNTAX INTEGER { + normal (1), + alarm (2) + } + +hh3cPOEPowerObjects OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 8 } + +hh3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 1 } + +hh3cPOEThresholdACMimimum OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Input threshold AC minimum. + It is a read-write node. + The value of this node is 'OCTET STRING', + it is used to describe a float value. + So this string should fit the following rule: + 1. This string should be terminated by '\0'; + 2. Every characters should be number or radix point; + 3. The radix point should occur only once, and it should not + be the first or the last character of the string. + The value of this node should be smaller than 264.0V and larger than 90.0V. + And it should be smaller than the hh3cPOEThresholdACMaximum." + ::= { hh3cPOEThresholdLimitObjs 1 } + +hh3cPOEThresholdACMaximum OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Input threshold AC maximum. + It is a read-write node. + The value of this node is 'OCTET STRING', + it is used to describe a float value. + So this string should fit the following rule: + 1. This string should be terminated by '\0'; + 2. Every characters should be number or radix point; + 3. The radix point should occur only once, and it should not + be the first or the last character of the string. + It should be smaller than 264.0V and larger than 90.0V. + And it should be larger than the hh3cPOEThresholdACMinimum." + ::= { hh3cPOEThresholdLimitObjs 2 } + +hh3cPOEThresholdDCMinimum OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Input threshold DC minimum. + It is a read-write node. + The value of this node is 'OCTET STRING', + it is used to describe a float value. + So this string should fit the following rule: + 1. This string should be terminated by '\0'; + 2. Every characters should be number or radix point; + 3. The radix point should occur only once, and it should not + be the first or the last character of the string. + It should be smaller than 47.0V and larger than 45.0V." + ::= { hh3cPOEThresholdLimitObjs 3 } + +hh3cPOEThresholdDCMaximum OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Input threshold DC maximum. + It is a read-write node. + The value of this node is 'OCTET STRING', + it is used to describe a float value. + So this string should fit the following rule: + 1. This string should be terminated by '\0'; + 2. Every characters should be number or radix point; + 3. The radix point should occur only once, and it should not + be the first or the last character of the string. + It should be smaller than 57.0V and larger than 55.0V." + ::= { hh3cPOEThresholdLimitObjs 4 } + +hh3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 2 } + +hh3cPOEPowerType OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the power." + ::= { hh3cPOESupModuleInfoObjs 1 } + +hh3cPOEPowerModuleNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the power modules." + ::= { hh3cPOESupModuleInfoObjs 2 } + +hh3cPOESupervisionModuleName OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the Supervision Module name on this POE power." + ::= { hh3cPOESupModuleInfoObjs 3 } + +hh3cPOESMMajorVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the high byte of the monitor module version." + ::= { hh3cPOESupModuleInfoObjs 4 } + +hh3cPOESMMinorVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the low byte of the monitor module version." + ::= { hh3cPOESupModuleInfoObjs 5 } + +hh3cPOESMFactorName OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the name of the manufactor." + ::= { hh3cPOESupModuleInfoObjs 6 } + +hh3cPOEModuleInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOEModuleInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of the module information on this POE power." + ::= { hh3cPOESupModuleInfoObjs 7 } + +hh3cPOEModuleInfoEntry OBJECT-TYPE + SYNTAX Hh3cPOEModuleInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The entry of the module information on this POE power." + INDEX { hh3cPOEModuleIndex } + ::= { hh3cPOEModuleInfoTable 1 } + +Hh3cPOEModuleInfoEntry ::= + SEQUENCE { + hh3cPOEModuleIndex + Integer32, + hh3cPOEModuleID + Integer32, + hh3cPOEModuleInfoPower + Integer32, + hh3cPOEModuleHardVerInfo + OCTET STRING + } + +hh3cPOEModuleIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index of the current module on this POE power. + It is also the index of hh3cPOEModuleInfoTable. + The range of this node is from 1 to hh3cPOEPowerModuleNum." + ::= { hh3cPOEModuleInfoEntry 1 } + +hh3cPOEModuleID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ID of the current module on this POE power." + ::= { hh3cPOEModuleInfoEntry 2 } + +hh3cPOEModuleInfoPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power of the current module on this POE power." + ::= { hh3cPOEModuleInfoEntry 3 } + +hh3cPOEModuleHardVerInfo OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hardware version information of the current module on this POE power." + ::= { hh3cPOEModuleInfoEntry 4 } + +hh3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 3 } + +hh3cPOEDCOutStateModuleNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module number on this POE power. + It is the maximum of the hh3cPOEDCOutStateIndex." + ::= { hh3cPOEDCOutStateObjects 1 } + +hh3cPOEDCOutStateTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOEDCOutStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of DC output power state on this POE power." + ::= { hh3cPOEDCOutStateObjects 2 } + +hh3cPOEDCOutStateEntry OBJECT-TYPE + SYNTAX Hh3cPOEDCOutStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The entry of the DC output power state on this POE power." + INDEX { hh3cPOEDCOutStateIndex } + ::= { hh3cPOEDCOutStateTable 1 } + + Hh3cPOEDCOutStateEntry ::= + SEQUENCE { + hh3cPOEDCOutStateIndex + Integer32, + hh3cPOEDCOutDCVolAlarm + DCAlarmState + } + +hh3cPOEDCOutStateIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index of the DC output power state on this POE power. + The range of this node is from 1 to hh3cPOEDCOutStateModuleNum." + ::= { hh3cPOEDCOutStateEntry 1 } + +hh3cPOEDCOutDCVolAlarm OBJECT-TYPE + SYNTAX DCAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DC output alarm of the DC output power state on this POE power. + The value of this node will be the following values: + normal (1), + underLimit (2), + aboveLimit (3), + fuseBroken (4), + switchOff (5), + otherError (6)." + ::= { hh3cPOEDCOutStateEntry 2 } + +hh3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 4 } + +hh3cPOEDCOutCurNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of DC output current on this POE power. + It is the maximum of hh3cPOEDCOutInfoIndex." + ::= { hh3cPOEDCOutInfoObjects 1 } + +hh3cPOEDCOutInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOEDCOutInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of the DC output information on this POE power." + ::= { hh3cPOEDCOutInfoObjects 2 } + +hh3cPOEDCOutInfoEntry OBJECT-TYPE + SYNTAX Hh3cPOEDCOutInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The entry of the DC output information on this POE power." + INDEX { hh3cPOEDCOutInfoIndex } + ::= { hh3cPOEDCOutInfoTable 1 } + +Hh3cPOEDCOutInfoEntry ::= + SEQUENCE { + hh3cPOEDCOutInfoIndex + Integer32, + hh3cPOEDCOutVol + OCTET STRING, + hh3cPOEDCOutInfoLoadCur + OCTET STRING + } + +hh3cPOEDCOutInfoIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index of the DC output information on this POE POWER. + The range of this node is from 1 to hh3cPOEDCOutCurNum." + ::= { hh3cPOEDCOutInfoEntry 1 } + +hh3cPOEDCOutVol OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DC output voltage of the current DC output on this POE power." + ::= { hh3cPOEDCOutInfoEntry 2 } + +hh3cPOEDCOutInfoLoadCur OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (1..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total load current of the current DC output on this POE power." + ::= { hh3cPOEDCOutInfoEntry 3 } + +hh3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 5 } + +hh3cPOEACSwitchStateModuleNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the AC swtich state module on this POE power. + It is the maximum of hh3cPOEACSwitchStateIndex." + ::= { hh3cPOEACSwitchStateModuleObjs 1 } + +hh3cPOEACSwitchStateTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOEACSwitchStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of the AC switch state on this POE power." + ::= { hh3cPOEACSwitchStateModuleObjs 2 } + +hh3cPOEACSwitchStateEntry OBJECT-TYPE + SYNTAX Hh3cPOEACSwitchStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The entry of the AC switch state on this POE power." + INDEX { hh3cPOEACSwitchStateIndex } + ::= { hh3cPOEACSwitchStateTable 1 } + +Hh3cPOEACSwitchStateEntry ::= + SEQUENCE { + hh3cPOEACSwitchStateIndex + Integer32, + hh3cPOEACSwitchState + SwitchState + } + +hh3cPOEACSwitchStateIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index of the AC switch state on this POE power. + The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum." + ::= { hh3cPOEACSwitchStateEntry 1 } + +hh3cPOEACSwitchState OBJECT-TYPE + SYNTAX SwitchState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The AC switch state on this POE power. + The value of this node will be one of the following values: + on (1), + off (2), + highVoltInput (3), + lowVoltInput (4)" + ::= { hh3cPOEACSwitchStateEntry 2 } + +hh3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 6 } + +hh3cPOEInCurStateModuleNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DC input current state of the module on this POE power. + It is the maximum of the hh3cPOESwitchStateVolExIndex." + ::= { hh3cPOEInCurStateObjects 1 } + +hh3cPOEInCurAState OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current A state in the DC input on this POE power. + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOEInCurStateObjects 2 } + +hh3cPOEInCurBState OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current B state in the DC input on this POE power. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOEInCurStateObjects 3 } + +hh3cPOEInCurCState OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current C state in the DC input on this POE power. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOEInCurStateObjects 4 } + +hh3cPOESwitchStateVolExTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOESwitchStateVolExEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "All alarm status of the VOL status. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOEInCurStateObjects 5 } + +hh3cPOESwitchStateVolExEntry OBJECT-TYPE + SYNTAX Hh3cPOESwitchStateVolExEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The hh3cPOESwitchStateVolExIndex will match the number of the VOL status." + INDEX { hh3cPOESwitchStateVolExIndex } + ::= { hh3cPOESwitchStateVolExTable 1 } + +Hh3cPOESwitchStateVolExEntry ::= + SEQUENCE { + hh3cPOESwitchStateVolExIndex + Integer32, + hh3cPOESwitchStateInVolAB + ACAlarmState, + hh3cPOESwitchStateInVolBC + ACAlarmState, + hh3cPOESwitchStateInVolCA + ACAlarmState + } + +hh3cPOESwitchStateVolExIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The object species the index of the VOL status. + The range of this node is from 1 to hh3cPOEInCurStateModuleNum." + ::= { hh3cPOESwitchStateVolExEntry 1 } + +hh3cPOESwitchStateInVolAB OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the VOL AB alarm in each VOL status. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOESwitchStateVolExEntry 2 } + +hh3cPOESwitchStateInVolBC OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the VOL BC alarm in each VOL status. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOESwitchStateVolExEntry 3 } + +hh3cPOESwitchStateInVolCA OBJECT-TYPE + SYNTAX ACAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the VOL CA alarm in each VOL status. + The value of this node will be one of the following values: + normal (1), + underLimit (2), + aboveLimit (3), + lackPhrase (4), + fuseBroken (5), + switchOff (6), + otherError (7)." + ::= { hh3cPOESwitchStateVolExEntry 4 } + +hh3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 7 } + +hh3cPOEAlarmStateModuleNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The object specifies the number of the power modules in alarm state." + ::= { hh3cPOEAlarmStateObjects 1 } + +hh3cPOEAlarmStateInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cPOEAlarmStateInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "All alarm states in the POE power modules." + ::= { hh3cPOEAlarmStateObjects 2 } + +hh3cPOEAlarmStateInfoEntry OBJECT-TYPE + SYNTAX Hh3cPOEAlarmStateInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The hh3cPOEAlarmModuleInfoIndex will match the number + of the power module." +INDEX { hh3cPOEAlarmModuleInfoIndex } + ::= { hh3cPOEAlarmStateInfoTable 1 } + +Hh3cPOEAlarmStateInfoEntry ::= + SEQUENCE { + hh3cPOEAlarmModuleInfoIndex + Integer32, + hh3cPOEModuleDisconnect + ModuleAlarmState, + hh3cPOEModuleInputError + ModuleAlarmState, + hh3cPOEModuleOutputError + ModuleAlarmState, + hh3cPOEModuleOverVoltage + ModuleAlarmState, + hh3cPOEModuleOverTemp + ModuleAlarmState, + hh3cPOEModuleFanError + ModuleAlarmState, + hh3cPOEModuleShutdown + ModuleAlarmState, + hh3cPOEModuleCurRestricted + ModuleAlarmState + } + +hh3cPOEAlarmModuleInfoIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table. + The range of this node is from 1 to hh3cPOEAlarmStateModuleNum." + ::= { hh3cPOEAlarmStateInfoEntry 1 } + +hh3cPOEModuleDisconnect OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The module does not link. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 2 } + +hh3cPOEModuleInputError OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + Input error. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 3 } + +hh3cPOEModuleOutputError OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + Output error. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 4 } + +hh3cPOEModuleOverVoltage OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The voltage is too high. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 5 } + +hh3cPOEModuleOverTemp OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The temperature is too high. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 6 } + +hh3cPOEModuleFanError OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The fan error. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 7 } + +hh3cPOEModuleShutdown OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The module is shutdown. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 8 } + +hh3cPOEModuleCurRestricted OBJECT-TYPE + SYNTAX ModuleAlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node specifies the alarm state: + The module limit the current. + The value of this node is one of the following values: + normal (1), + alarm (2)." + ::= { hh3cPOEAlarmStateInfoEntry 9 } + +Hh3cPDDisableState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "PD disabled State." + SYNTAX INTEGER{ + unknown(0), + overInrush(1), + lessMPSCurrent(2), + peakPower(3), + overVoltage(4), + underVoltage(5), + overTemperature(6), + shortCircuit(7) + } + +hh3cPseNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 11 } +hh3cPseNotificationPrefix OBJECT IDENTIFIER ::= { hh3cPseNotification 0 } + + hh3cPsePDDisableNotification NOTIFICATION-TYPE + OBJECTS{ hh3cPsePortGroupIndex, hh3cPsePortIndex, hh3cPsePortDisableInfo } + STATUS current + DESCRIPTION + "The PD has been powered off." + ::= { hh3cPseNotificationPrefix 1 } + +hh3cPseNotificationObjects OBJECT IDENTIFIER ::= { hh3cPseNotification 1 } + + hh3cPsePortGroupIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "This variable uniquely identifies the group + containing the port to which a power Ethernet PSE is + connected." + ::= { hh3cPseNotificationObjects 1 } + + hh3cPsePortIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "This variable uniquely identifies the power Ethernet PSE + port within group pethPsePortGroupIndex to which the + power Ethernet PSE entry is connected." + ::= { hh3cPseNotificationObjects 2 } + + hh3cPsePortDisableInfo OBJECT-TYPE + SYNTAX Hh3cPDDisableState + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + " + Reason that caused PSE port power failure. + The calue of this node is one of the following values: + unknown(0), + overInrush(1), + lessMPSCurrent(2), + peakPower(3), + overVoltage(4), + underVoltage(5), + overTemperature(6), + shortCircuit(7). + " + ::= { hh3cPseNotificationObjects 3 } + +END + |