summaryrefslogtreecommitdiff
path: root/MIBS/comware/HH3C-PEX-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/comware/HH3C-PEX-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/comware/HH3C-PEX-MIB')
-rw-r--r--MIBS/comware/HH3C-PEX-MIB415
1 files changed, 415 insertions, 0 deletions
diff --git a/MIBS/comware/HH3C-PEX-MIB b/MIBS/comware/HH3C-PEX-MIB
new file mode 100644
index 0000000..847a25b
--- /dev/null
+++ b/MIBS/comware/HH3C-PEX-MIB
@@ -0,0 +1,415 @@
+-- ============================================================================
+-- Copyright (c) 2004-2015 New H3C Tech. Co., Ltd. All rights reserved.
+--
+-- Description: Port Extender (PEX) information MIB
+-- Reference:
+-- Version: V1.2
+-- History:
+-- V1.0 2012-11-12 Initial version by Yang Fan
+-- V1.1 2014-03-31 Changed MIB node name to PEX by zushuzhi
+-- V1.2 2015-10-15 Added hh3cPexDeviceInfoTable and hh3cPexTopoTable
+-- by zushuzhi
+-- ============================================================================
+HH3C-PEX-MIB DEFINITIONS ::= BEGIN
+IMPORTS
+ hh3cCommon
+ FROM HH3C-OID-MIB
+ entPhysicalIndex, entPhysicalDescr
+ FROM ENTITY-MIB
+ Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ RowStatus, DisplayString
+ FROM SNMPv2-TC;
+
+hh3cPex MODULE-IDENTITY
+ LAST-UPDATED "201510151129Z" -- 15th October, 2015 at 11:29 GMT
+ ORGANIZATION
+ "New H3C Technologies Co., Ltd."
+ CONTACT-INFO
+ "Platform Team New H3C Technologies Co., Ltd.
+ Haidian District Beijing P.R. China
+ Http://www.h3c.com
+ Zip:100085"
+ DESCRIPTION
+ "This MIB is used to manage Port Extender (PEX)
+ information. This MIB is applicable to products that support PEX."
+ REVISION "201510151129Z"
+ DESCRIPTION
+ "Added hh3cPexDeviceInfoTable and hh3cPexTopoTable."
+ REVISION "201211121129Z"
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { hh3cCommon 129 }
+
+-- PEX Specification Information
+
+hh3cPexSpecInfo OBJECT IDENTIFIER ::= { hh3cPex 1 }
+
+hh3cPexPortMinId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lowest PEX port ID that can be used to uniquely identify a PEX port."
+ ::= { hh3cPexSpecInfo 1 }
+
+hh3cPexPortMaxId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Highest PEX port ID that can be used to uniquely identify a PEX port."
+ ::= { hh3cPexSpecInfo 2 }
+
+hh3cPexMinAssociateId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lowest ID that can be assigned to a port extender (PEX)."
+ ::= { hh3cPexSpecInfo 3 }
+
+hh3cPexMaxAssociateId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Highest ID that can be assigned to a PEX."
+ ::= { hh3cPexSpecInfo 4 }
+
+hh3cPexMaxPortPerPexPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum number of ports that can be bound to a PEX port."
+ ::= { hh3cPexSpecInfo 5 }
+
+-- PEX Information
+
+hh3cPexTable OBJECT IDENTIFIER ::= { hh3cPex 2 }
+
+hh3cPexPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPexPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects used to configure the PEX ports."
+ ::= { hh3cPexTable 1 }
+
+hh3cPexPortEntry OBJECT-TYPE
+ SYNTAX Hh3cPexPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a PEX."
+ INDEX
+ {
+ hh3cPexPortId
+ }
+ ::= { hh3cPexPortTable 1 }
+
+Hh3cPexPortEntry ::= SEQUENCE
+ {
+ hh3cPexPortId Integer32,
+ hh3cPexPortAssociateId Integer32,
+ hh3cPexPortEntPhysicalIndex Integer32,
+ hh3cPexPortDescr DisplayString,
+ hh3cPexPortStatus INTEGER,
+ hh3cPexPortRowStatus RowStatus
+ }
+
+hh3cPexPortId OBJECT-TYPE
+ SYNTAX Integer32(1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "ID that can be used to uniquely identify a PEX port. The value range
+ is hh3cPexPortMinId to hh3cPexPortMaxId."
+ ::= { hh3cPexPortEntry 1 }
+
+hh3cPexPortAssociateId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ID assigned to a PEX. The
+ value range is hh3cPexMinAssociateId to hh3cPexMaxAssociateId.
+ The value is 0xffff if the PEX is not assigned an ID.
+ For a successful configuration, the ID should not be used by any
+ other PEX."
+ DEFVAL { 65535 }
+ ::= { hh3cPexPortEntry 2 }
+
+hh3cPexPortEntPhysicalIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Entity index of a PEX in the IRF. A value of zero
+ indicates that the PEX is not online."
+ DEFVAL { 0 }
+ ::= { hh3cPexPortEntry 3 }
+
+hh3cPexPortDescr OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..79))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description for the PEX port. The default value is
+ 'pex-port XXXX', where 'XXXX' is hh3cPexPortId.
+ Writing a zero-length string to this object resets the value to the
+ default."
+ ::= { hh3cPexPortEntry 4 }
+
+hh3cPexPortStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ offline(1),
+ loading(2),
+ online(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the PEX.
+ offline: The PEX is absent or its configuration is incomplete.
+ loading: The PEX is loading software.
+ online: The PEX is operating correctly."
+ DEFVAL { offline }
+ ::= { hh3cPexPortEntry 5 }
+
+hh3cPexPortRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The control that allows creation and deletion of entries.
+ Values include createAndGo, active, and destroy.
+ If the row to be created or modified already exists,
+ an error message is returned. If the row to be deleted does not exist,
+ a success message is returned."
+ ::= { hh3cPexPortEntry 6 }
+
+
+-- PEX PhyPort Information
+
+hh3cPexPhyPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPexPhyPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects used to manage physical ports
+ that can be bound or are already bound to a PEX port."
+ ::= { hh3cPexTable 2 }
+
+hh3cPexPhyPortEntry OBJECT-TYPE
+ SYNTAX Hh3cPexPhyPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a physical port that can be bound to or
+ has been bound to a PEX port."
+ INDEX
+ {
+ entPhysicalIndex
+ }
+ ::= { hh3cPexPhyPortTable 1 }
+
+Hh3cPexPhyPortEntry ::= SEQUENCE
+ {
+ hh3cPexPhyPortStatus INTEGER,
+ hh3cPexPhyPortBelongToPexPort Integer32,
+ hh3cPexPhyPortNeighborEntIndex Integer32
+ }
+
+hh3cPexPhyPortStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ down(2),
+ blocked(3),
+ forwarding(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the physical port that is bound to a PEX port.
+ The following are status values:
+ unknown: The physical port is not bound to any PEX port.
+ down: The physical port is link down.
+ blocked: The physical port is blocked and cannot forward traffic.
+ forwarding: The physical port can forwarding traffic."
+ DEFVAL { unknown }
+ ::= { hh3cPexPhyPortEntry 1 }
+
+hh3cPexPhyPortBelongToPexPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "ID of the PEX port to which the physical port belongs. The value
+ range is hh3cPexPortMinId to hh3cPexPortMaxId. A value of zero
+ indicates that the port doesn't belong to any PEX port."
+ DEFVAL { 0 }
+ ::= { hh3cPexPhyPortEntry 2 }
+
+hh3cPexPhyPortNeighborEntIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Entity index of a physical port that connects the PEX to the parent
+ device. This value is identical to entPhysicalIndex in ENTITY-MIB.
+ A value of zero indicates that the physical port is not bound to any
+ PEX port or is not up."
+ ::= { hh3cPexPhyPortEntry 3 }
+
+-- PEX Topology Information
+hh3cPexDeviceInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPexDeviceInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains online PEXs in the IRF system."
+ ::= { hh3cPexTable 3 }
+
+hh3cPexDeviceInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cPexDeviceInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a PEX in the IRF system. The index is the PEX
+ entity index."
+ INDEX
+ {
+ entPhysicalIndex
+ }
+ ::= { hh3cPexDeviceInfoTable 1 }
+
+Hh3cPexDeviceInfoEntry ::= SEQUENCE
+ {
+ hh3cPexDeviceStatus INTEGER,
+ hh3cPexDeviceAssociateId Integer32
+ }
+
+hh3cPexDeviceStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal(1),
+ faulty(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the PEX.
+ normal: The PEX is operating correctly.
+ faulty: The PEX is faulty."
+ ::= { hh3cPexDeviceInfoEntry 1 }
+
+hh3cPexDeviceAssociateId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ID assigned to the PEX."
+ ::= { hh3cPexDeviceInfoEntry 2 }
+
+hh3cPexTopoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPexTopoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains information about the PEX physical ports and
+ neighbor ports on PEXs."
+ ::= { hh3cPexTable 4 }
+
+hh3cPexTopoEntry OBJECT-TYPE
+ SYNTAX Hh3cPexTopoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a PEX link."
+ INDEX
+ {
+ entPhysicalIndex
+ }
+ ::= { hh3cPexTopoTable 1 }
+
+Hh3cPexTopoEntry ::= SEQUENCE
+ {
+ hh3cPexNeighborEntIndex Integer32
+ }
+
+hh3cPexNeighborEntIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Entity index of a PEX in the IRF system."
+ ::= { hh3cPexTopoEntry 1 }
+
+-- PEX Traps
+
+hh3cPexTraps OBJECT IDENTIFIER ::= { hh3cPex 3 }
+
+hh3cPexTrapPrefix OBJECT IDENTIFIER ::= { hh3cPexTraps 0 }
+
+hh3cPexPortOnline NOTIFICATION-TYPE
+ OBJECTS
+ {
+ hh3cPexPortId,
+ hh3cPexPortDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "An hh3cPexPortOnline trap is sent when the PEX transitions to
+ online state."
+ ::= { hh3cPexTrapPrefix 1 }
+
+hh3cPexPortOffline NOTIFICATION-TYPE
+ OBJECTS
+ {
+ hh3cPexPortId,
+ hh3cPexPortDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "An hh3cPexPortOnline trap is sent when the PEX transitions to
+ offline state."
+ ::= { hh3cPexTrapPrefix 2 }
+
+hh3cPexPhyPortForwarding NOTIFICATION-TYPE
+ OBJECTS
+ {
+ hh3cPexEntPhysicalIndexBind,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "An hh3cPexPhyPortForwarding trap is sent when the PEX physical port
+ transitions to forwarding state."
+ ::= { hh3cPexTrapPrefix 3 }
+
+hh3cPexPhyPortBlocked NOTIFICATION-TYPE
+ OBJECTS
+ {
+ hh3cPexEntPhysicalIndexBind,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "An hh3cPexPhyPortBlocked trap is sent when the PEX physical port
+ transitions from forwarding state to blocked state."
+ ::= { hh3cPexTrapPrefix 4 }
+
+hh3cPexTrapObjects OBJECT IDENTIFIER ::= { hh3cPex 4 }
+
+hh3cPexEntPhysicalIndexBind OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This index is identical to entPhysicalIndex in ENTITY-MIB."
+ ::= { hh3cPexTrapObjects 1 }
+END