summaryrefslogtreecommitdiff
path: root/MIBS/comware/HH3C-ENTITY-EXT-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/comware/HH3C-ENTITY-EXT-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/comware/HH3C-ENTITY-EXT-MIB')
-rw-r--r--MIBS/comware/HH3C-ENTITY-EXT-MIB1847
1 files changed, 1847 insertions, 0 deletions
diff --git a/MIBS/comware/HH3C-ENTITY-EXT-MIB b/MIBS/comware/HH3C-ENTITY-EXT-MIB
new file mode 100644
index 0000000..073bc26
--- /dev/null
+++ b/MIBS/comware/HH3C-ENTITY-EXT-MIB
@@ -0,0 +1,1847 @@
+-- =================================================================
+-- Copyright (c) 2004-2015 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
+--
+-- Description: description of entity extend properties.
+-- Reference:
+-- History V3.2
+-- V1.0 Created by weixinzhe, Thursday, April 22, 2004 at 18:26:02
+-- V1.1 modified by yelinhui, add hh3cEntityExtMacAddress
+-- V1.2 modified by panxidong, add hh3cEntityExtErrorStatus
+-- V1.3 2004-10-12 updated by gaolong
+-- Remove BITS from IMPORTS
+-- V1.4 2005-02-25 modified by longyin
+-- Add error status stackPortBlocked(22) and stackPortFailed(23)
+-- for hh3cEntityExtErrorStatus
+-- V1.5 2006-05-16 modified by wangsihai
+-- Add error status sensorError(81) in hh3cEntityExtErrorStatus
+-- V1.6 2006-07-03 modified by lifengguang
+-- Add hh3cEntityExtManuTable
+-- V1.7 2007-09-21 modified by lifengguang
+-- Add notification object hh3cEntityExtSFPAlarmOn and hh3cEntityExtSFPAlarmOff
+-- Add hh3cEntityExtPowerTable
+-- V1.8 2007-11-19 modified by jinyi
+-- Add hh3cEntityExtCpuMaxUsage
+-- V1.9 2008-02-27 modified by lifengguang
+-- Add Trap nodes: hh3cEntityExtSFPPhony
+-- V2.0 2008-07-11 modified by lisong
+-- Add hh3cProcessTable
+-- Add notification object hh3cEntityInsert and hh3cEntityRemove
+-- V2.1 2008-07-14 modified by lifengguang
+-- Add error status hardwareFaulty(91) in hh3cEntityExtErrorStatus
+-- Add Trap nodes: hh3cEntityExtForcedPowerOff and hh3cEntityExtForcedPowerOn
+-- Add Trap nodes: hh3cEntityExtFaultAlarmOn and hh3cEntityExtFaultAlarmOff
+-- V2.2 2008-10-24 modified by lifengguang
+-- Add nodes hh3cEntityExtLowerTemperatureThreshold and
+-- hh3cEntityExtShutdownTemperatureThreshold in hh3cEntityExtStateTable
+-- Add trap nodes hh3cEntityExtResourceLack and hh3cEntityExtResourceEnough
+-- in hh3cEntityExtTrapsPrefix
+-- Add trap nodes hh3cEntityExtTemperatureLower, hh3cEntityExtTemperatureTooUp
+-- and hh3cEntityExtTemperatureNormal in hh3cEntityExtTrapsPrefix
+-- V2.3 2009-04-07 Added trap nodes hh3cEntityExternalAlarmOccur and
+-- hh3cEntityExternalAlarmRecover
+-- v2.4 2009-05-05 Added hh3cEntityExtCpuAvgUsage, hh3cEntityExtMemAvgUsage,
+-- hh3cEntityExtPhyMemSize, hh3cEntityExtMemType, hh3cEntityExtPhyCpuFrequency,
+-- hh3cEntityExtFirstUsedDate,
+-- hh3cEntityExtCpuUsageThresholdRecover, hh3cEntityExtMemUsageThresholdRecover
+-- V2.5 2010-08-09
+-- Added hh3cEntityExtShutdownLowerTemperatureThreshold,
+-- hh3cEntityExtCriticalLowerTemperatureThreshold,
+-- hh3cEntityExtCritLowerTempThresholdNotification and
+-- hh3cEntityExtTemperatureTooLow by zhanglei 06807.
+-- Added hh3cEntityExtMemAllocatedFailed, hh3cEntityExtECCParityAlarm,
+-- hh3cEntityExtTrapDescription, hh3cEntityExtECCParityAlarmStatus
+-- by zhangqingjun 02357.
+-- Modified description of hh3cEntityExtPhyMemSize by haoyan 06611.
+-- V2.6 2010-12-06
+-- Added hh3cEntityExtFanDirectionNotPreferred, hh3cEntityExtFanDirectionNotAccord
+-- by lifengguang 03035.
+-- V2.7 2011-04-06
+-- Added hh3cEntityExtSFPInvalid, hh3cEntityExtSFPInvalidNow and
+-- hh3cEntityExtSFPInvalidInDays by songhao 02718.
+-- Changed SYNTAX of hh3cEntityExtMemSize and hh3cEntityExtPhyMemSize
+-- from Integer32 to Unsigned32 by songhao 02718.
+-- V2.8 2011-08-30
+-- Added hh3cEntityExtCpuUsageRecoverThreshold;
+-- Added hh3cEntityExtCpuUsageRecoverThreshold to hh3cEntityExtCpuUsageThresholdNotfication and
+-- hh3cEntityExtCpuUsageThresholdRecover by shuaixiaojuan 04117.
+-- Added hh3cEntityExtFirstTrapTime by duyanbing 04404.
+-- V2.9 2013-04-27
+-- Added hh3cEntityExtMemSizeRev by fangliwen 08502.
+-- Added trap nodes hh3cEntityExtMemUsageThresholdOverTrap and
+-- hh3cEntityExtMemUsageThresholdRecoverTrap by fangliwen 08502.
+-- V3.0 2013-12-16
+-- Added hh3cEntityExtCpuUsageIn1Minute and hh3cEntityExtCpuUsageIn5Minutes
+-- by fangliwen 08502.
+-- V3.1 2014-01-24
+-- Added hh3cEntityExtVoltageObjects by fangliwen 08502.
+-- Added trap nodes hh3cEntityExtVoltageNormal, hh3cEntityExtVoltageTooLow,
+-- hh3cEntityExtVoltageLower, hh3cEntityExtVoltageHigher and
+-- hh3cEntityExtVoltageTooHigh by fangliwen 08502.
+-- V3.2 2015-01-12
+-- Added trap nodes hh3cEntityExtSFPAlarmOnEx, hh3cEntityExtSFPAlarmOffEx by fangliwen 08502.
+-- =================================================================
+HH3C-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ hh3cCommon
+ FROM HH3C-OID-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32,
+ Unsigned32, Gauge32, TimeTicks
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, MacAddress, DateAndTime, DisplayString
+ FROM SNMPv2-TC
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB
+ entPhysicalIndex, entPhysicalName, entPhysicalDescr
+ FROM ENTITY-MIB
+ CounterBasedGauge64
+ FROM HCNUM-TC;
+
+ hh3cEntityExtend MODULE-IDENTITY
+ LAST-UPDATED "201501120000Z"
+ ORGANIZATION
+ "Hangzhou H3C Technologies Co., Ltd."
+ CONTACT-INFO
+ "Platform Team H3C Technologies Co., Ltd.
+ Hai-Dian District Beijing P.R. China
+ http://www.h3c.com
+ Zip: 100085"
+ DESCRIPTION
+ "The private MIB file includes the general extent
+ information of the device."
+ ::= { hh3cCommon 6 }
+
+ Hh3cAdminState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The administrative state for this object, and it is possible to
+ set the state when needed.
+ A value of locked means the resource is administratively prohibited
+ from use. A value of shuttingDown means that usage is
+ administratively limited to current instances of use.
+ A value of unlocked means the resource is not administratively
+ prohibited from use."
+ REFERENCE
+ "ITU Recommendation X.731, 'Information Technology - Open
+ Systems Interconnection - System Management: State
+ Management Function', 1992"
+ SYNTAX INTEGER
+ {
+ notSupported(1),
+ locked(2),
+ shuttingDown(3),
+ unlocked(4)
+ }
+
+ Hh3cOperState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ " Represents the possible values of operational states.
+ A value of disabled means the resource is totally
+ inoperable. A value of enabled means the resource
+ is partially or fully operable."
+ REFERENCE
+ "ITU Recommendation X.731, 'Information Technology - Open
+ Systems Interconnection - System Management: State
+ Management Function', 1992"
+ SYNTAX INTEGER
+ {
+ notSupported (1),
+ disabled(2),
+ enabled(3),
+ dangerous(4)
+ }
+ Hh3cAlarmStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Represents the possible values of alarm status.
+ When no bits of this attribute are set, then none of the
+ status conditions described below are present. When the
+ value of under repair is set, the resource is currently
+ being repaired.
+
+ When the value of critical is set, one or more critical
+ alarms are active against the resource. When the value of
+ major is set, one or more major alarms are active against
+ the resource. When the value of minor is set, one or more
+ minor alarms are active against the resource. When the
+ value of warning is set, one or more warning alarms are
+ active against the resource. When the value of
+ indeterminate is set, one or more alarms of indeterminate
+ severity are active against the resource.
+ When the value of alarm outstanding is set, one or more
+ alarms is active against the resource. The fault may or may
+ not be disabling."
+ REFERENCE
+ "ITU Recommendation X.731, 'Information Technology - Open
+ Systems Interconnection - System Management: State
+ Management Function', 1992"
+ SYNTAX BITS
+ {
+ notSupported (0),
+ underRepair(1),
+ critical(2),
+ major(3),
+ minor(4),
+ alarmOutstanding(5),
+ warning (6), -- Not defined in X.731
+ indeterminate (7) -- Not defined in X.731
+ }
+
+
+ Hh3cStandbyStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ " Represents the possible values of standby status.
+
+ A value of hotStandby means the resource is not providing
+ service, but is will be immediately able to take over the
+ role of the resource to be backed-up, without the need for
+ initialization activity, and will contain the same
+ information as the resource to be backed up. A value of
+ coldStandy means that the resource is to back-up another
+ resource, but will not be immediately able to take over
+ the role of a resource to be backed up, and will require
+ some initialization activity. A value of providingService
+ means the resource is providing service."
+ REFERENCE
+ "ITU Recommendation X.731, 'Information Technology - Open
+ Systems Interconnection - System Management: State
+ Management Function', 1992"
+ SYNTAX INTEGER
+ {
+ notSupported (1),
+ hotStandby(2),
+ coldStandby(3),
+ providingService(4)
+ }
+
+
+ hh3cEntityExtObjects OBJECT IDENTIFIER ::= { hh3cEntityExtend 1 }
+
+
+-- MIB contains four groups
+
+ hh3cEntityExtState OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 1 }
+
+ hh3cEntityExtStateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cEntityExtStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains one row per physical entity, There is
+ always at least one row for an 'overall' physical entity.
+ The information in each row may be not include all the object
+ in this table, because of the entity need not some of the
+ information here."
+ ::= { hh3cEntityExtState 1 }
+
+ hh3cEntityExtStateEntry OBJECT-TYPE
+ SYNTAX Hh3cEntityExtStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The information about a particular physical entity."
+ INDEX { hh3cEntityExtPhysicalIndex }
+ ::= { hh3cEntityExtStateTable 1 }
+
+ Hh3cEntityExtStateEntry ::= SEQUENCE {
+ hh3cEntityExtPhysicalIndex
+ Integer32,
+ hh3cEntityExtAdminStatus
+ Hh3cAdminState,
+ hh3cEntityExtOperStatus
+ Hh3cOperState,
+ hh3cEntityExtStandbyStatus
+ Hh3cStandbyStatus,
+ hh3cEntityExtAlarmLight
+ Hh3cAlarmStatus,
+ hh3cEntityExtCpuUsage
+ Integer32,
+ hh3cEntityExtCpuUsageThreshold
+ Integer32,
+ hh3cEntityExtMemUsage
+ Integer32,
+ hh3cEntityExtMemUsageThreshold
+ Integer32,
+ hh3cEntityExtMemSize
+ Unsigned32,
+ hh3cEntityExtUpTime
+ Integer32,
+ hh3cEntityExtTemperature
+ Integer32,
+ hh3cEntityExtTemperatureThreshold
+ Integer32,
+ hh3cEntityExtVoltage
+ Integer32,
+ hh3cEntityExtVoltageLowThreshold
+ Integer32,
+ hh3cEntityExtVoltageHighThreshold
+ Integer32,
+ hh3cEntityExtCriticalTemperatureThreshold
+ Integer32,
+ hh3cEntityExtMacAddress
+ MacAddress,
+ hh3cEntityExtErrorStatus
+ INTEGER,
+ hh3cEntityExtCpuMaxUsage
+ Integer32,
+ hh3cEntityExtLowerTemperatureThreshold
+ Integer32,
+ hh3cEntityExtShutdownTemperatureThreshold
+ Integer32,
+ hh3cEntityExtPhyMemSize
+ Unsigned32,
+ hh3cEntityExtPhyCpuFrequency
+ Integer32,
+ hh3cEntityExtFirstUsedDate
+ DateAndTime,
+ hh3cEntityExtCpuAvgUsage
+ Integer32,
+ hh3cEntityExtMemAvgUsage
+ Integer32,
+ hh3cEntityExtMemType
+ OCTET STRING,
+ hh3cEntityExtCriticalLowerTemperatureThreshold
+ Integer32,
+ hh3cEntityExtShutdownLowerTemperatureThreshold
+ Integer32,
+ hh3cEntityExtCpuUsageRecoverThreshold
+ Integer32,
+ hh3cEntityExtMemSizeRev
+ CounterBasedGauge64,
+ hh3cEntityExtCpuUsageIn1Minute
+ Integer32,
+ hh3cEntityExtCpuUsageIn5Minutes
+ Integer32
+ }
+
+ hh3cEntityExtPhysicalIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of hh3cEntityExtStateTable.
+ This index is identical to entPhysicalIndex in ENTITY-MIB"
+ ::= { hh3cEntityExtStateEntry 1 }
+
+ hh3cEntityExtAdminStatus OBJECT-TYPE
+ SYNTAX Hh3cAdminState
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The administrative state for this object."
+ ::= { hh3cEntityExtStateEntry 2 }
+
+ hh3cEntityExtOperStatus OBJECT-TYPE
+ SYNTAX Hh3cOperState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operate state for this object."
+ ::= { hh3cEntityExtStateEntry 3 }
+
+ hh3cEntityExtStandbyStatus OBJECT-TYPE
+ SYNTAX Hh3cStandbyStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used for monitoring standby status.
+ Not all entities support this object."
+ ::= { hh3cEntityExtStateEntry 4 }
+
+ hh3cEntityExtAlarmLight OBJECT-TYPE
+ SYNTAX Hh3cAlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm status for this entity. It does not include
+ the severity of alarms raised on child components. In
+ this condition, there will be a alarm light on the entity,
+ the object should have the same status with it."
+ ::= { hh3cEntityExtStateEntry 5 }
+
+ hh3cEntityExtCpuUsage OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU usage for this entity. Generally, the overall
+ CPU usage on the entity is calculated, independent of
+ the number of CPUs on the entity."
+ ::= { hh3cEntityExtStateEntry 6 }
+
+ hh3cEntityExtCpuUsageThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the CPU usage. When the CPU usage exceeds
+ the threshold, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 7 }
+
+ hh3cEntityExtMemUsage OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The memory usage for the entity. This object indicates what
+ percent of memory are used."
+ ::= { hh3cEntityExtStateEntry 8 }
+
+ hh3cEntityExtMemUsageThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the Memory usage, When the memory usage
+ exceeds the threshold, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 9 }
+
+ hh3cEntityExtMemSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The size of memory for the entity.
+
+ If the amount of memory exceeds 4,294,967,295 bytes,
+ the value remains 4,294,967,295 bytes."
+ ::= { hh3cEntityExtStateEntry 10 }
+
+ hh3cEntityExtUpTime OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The uptime for the entity. The meaning of uptime is
+ when the entity is up, and the value of the object
+ will add 1 seconds while the entity is running."
+ ::= { hh3cEntityExtStateEntry 11 }
+
+ hh3cEntityExtTemperature OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature for the entity."
+ ::= { hh3cEntityExtStateEntry 12 }
+
+ hh3cEntityExtTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the temperature. When the temperature
+ exceeds the threshold, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 13 }
+
+ hh3cEntityExtVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage for the entity."
+ ::= { hh3cEntityExtStateEntry 14 }
+
+ hh3cEntityExtVoltageLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The low-threshold for the voltage.
+ When voltage is lower than low-threshold, a notification will be
+ sent."
+ ::= { hh3cEntityExtStateEntry 15 }
+
+ hh3cEntityExtVoltageHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The high-threshold for the voltage.
+ When voltage greater than high-threshold, a notification will be
+ sent."
+ ::= { hh3cEntityExtStateEntry 16 }
+
+ hh3cEntityExtCriticalTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The threshold for the critical Temperature. When temperature
+ exceeds the critical temperature, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 17 }
+
+ hh3cEntityExtMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MAC Address of the entity."
+ ::= { hh3cEntityExtStateEntry 18 }
+
+ hh3cEntityExtErrorStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notSupported(1),
+ normal(2),
+ postFailure(3),
+ entityAbsent(4),
+ poeError(11),
+ stackError(21),
+ stackPortBlocked(22),
+ stackPortFailed(23),
+ sfpRecvError(31),
+ sfpSendError(32),
+ sfpBothError(33),
+ fanError (41),
+ psuError(51),
+ rpsError(61),
+ moduleFaulty(71),
+ sensorError(81),
+ hardwareFaulty(91)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicate the error state of this entity object. Now it only
+ supports Port, general power supply, RPS power supply and
+ board/Subcard. It may have one of these values.
+ The following four values can be used for all kinds of entities.
+
+ notSupported(1) means this entity cannot support this function.
+ normal(2) means the statement of this entity is normal. for ports,
+ it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and
+ half-duplex. For fan, power supply and board-Subcard, it means
+ their states are normal.
+ postFailure(3) means the entity fails to POST.
+ entityAbsent(4) means the entity is absent now.
+
+
+ The following values is depended on the entity.
+
+ For Port entities, it may have the following values. If its POST
+ is failure,
+ then the value of the instance will be postFailure(3), otherwise
+ the value will be normal(2).
+
+ If enable power supply over Ethernet on this port is failure,
+ the value of this instance will be poeError(11), otherwise it will
+ be normal(2).
+
+ For stack port, if it connects to another stack port normally, and
+ these two units merge into one stack, then the value of this
+ instance will be normal(2).
+ If something wrong occurs and the unit cannot merge into stack,
+ the value of this instance will be stackPortFailed(23). If the
+ stack port forms resilient daisy chain with another stack port
+ on the other unit, the value of this instance will be
+ stackPortBlocked(22).
+
+
+ For SFP ports, if it fail to receive, the value of this instance
+ will be sfpRecvError(31), if it fail to send, the value is
+ sfpSendError(32), if it fail to send and receive, the value is
+ sfpBothError(33), otherwise it will be normal(2).
+
+ fanError(41) means that the fan stops working.
+
+ psuError(51) means that the Power Supply Unit is in the state of
+ fault.
+
+ rpsError(61) means the RPS is in the state of fault.
+
+ moduleFaulty(71) means the Module is in the state of fault.
+
+ sensorError(81) means the sensor is in the state of fault.
+
+ hardwareFaulty(91) means the hardware of specified entity is in the state of fault.
+
+ NMS must be compatible with the states which may be added
+ in the future."
+ ::= { hh3cEntityExtStateEntry 19 }
+
+ hh3cEntityExtCpuMaxUsage OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximal CPU usage for the entity in the period of time."
+ ::= { hh3cEntityExtStateEntry 20 }
+
+ hh3cEntityExtLowerTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the lower Temperature. When temperature runs
+ under the threshold, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 21 }
+
+ hh3cEntityExtShutdownTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the shutdown Temperature. When temperature
+ exceeds the threshold, a notification will be sent and the entity
+ will be shutdown."
+ ::= { hh3cEntityExtStateEntry 22 }
+
+ hh3cEntityExtPhyMemSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The memory size of entity. This is the physical attribute of entity."
+ ::= { hh3cEntityExtStateEntry 23 }
+
+ hh3cEntityExtPhyCpuFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU frequency of entity. Unit of measure is MHZ."
+ ::= { hh3cEntityExtStateEntry 24 }
+
+ hh3cEntityExtFirstUsedDate OBJECT-TYPE
+ SYNTAX DateAndTime (SIZE(8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The first used date of the entity."
+ ::= { hh3cEntityExtStateEntry 25 }
+
+ hh3cEntityExtCpuAvgUsage OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average CPU usage for the entity in a period of time."
+ ::= { hh3cEntityExtStateEntry 26 }
+
+ hh3cEntityExtMemAvgUsage OBJECT-TYPE
+ SYNTAX Integer32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average memory usage for the entity in a period of time."
+ ::= { hh3cEntityExtStateEntry 27 }
+
+ hh3cEntityExtMemType OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE (0..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The memory type of entity."
+ ::= { hh3cEntityExtStateEntry 28 }
+
+ hh3cEntityExtCriticalLowerTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the critical Temperature. When temperature
+ exceeds the critical lower temperature, a notification will be sent."
+ ::= { hh3cEntityExtStateEntry 29 }
+
+ hh3cEntityExtShutdownLowerTemperatureThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold for the shutdown Temperature. When temperature
+ exceeds the lower threshold, a notification will be sent and the entity
+ will be shutdown."
+ ::= { hh3cEntityExtStateEntry 30 }
+
+ hh3cEntityExtCpuUsageRecoverThreshold OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The recover threshold for the CPU usage. When the CPU usage falls down to
+ the threshold, a notification is sent. The hh3cEntityExtCpuUsageRecoverThreshold
+ must be less than or equal to the hh3cEntityExtCpuUsageThreshold."
+ DEFVAL { 100 }
+ ::= { hh3cEntityExtStateEntry 31 }
+
+ hh3cEntityExtMemSizeRev OBJECT-TYPE
+ SYNTAX CounterBasedGauge64
+ UNITS "bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Size of memory space for the entity.
+
+ This node is used to replace hh3cEntityExtMemSize."
+ ::= { hh3cEntityExtStateEntry 32 }
+
+ hh3cEntityExtCpuUsageIn1Minute OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU usage in last one minute for this entity.
+ Generally, the overall CPU usage on the entity is
+ calculated, independent of the number of CPUs on
+ the entity."
+ ::= { hh3cEntityExtStateEntry 33 }
+
+ hh3cEntityExtCpuUsageIn5Minutes OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CPU usage in last five minutes for this entity.
+ Generally, the overall CPU usage on the entity is
+ calculated, independent of the number of CPUs on
+ the entity."
+ ::= { hh3cEntityExtStateEntry 34 }
+
+ hh3cEntityExtManu OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 2 }
+
+ hh3cEntityExtManuTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cEntityExtManuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table about device manufacture information."
+ ::= { hh3cEntityExtManu 1 }
+
+ hh3cEntityExtManuEntry OBJECT-TYPE
+ SYNTAX Hh3cEntityExtManuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The device manufacture information about a particular physical
+ entity."
+ INDEX { hh3cEntityExtManuPhysicalIndex }
+ ::= { hh3cEntityExtManuTable 1 }
+
+ Hh3cEntityExtManuEntry ::= SEQUENCE {
+ hh3cEntityExtManuPhysicalIndex
+ Integer32,
+ hh3cEntityExtManuSerialNum
+ SnmpAdminString,
+ hh3cEntityExtManuBuildInfo
+ SnmpAdminString,
+ hh3cEntityExtManuBOM
+ SnmpAdminString,
+ hh3cEntityExtMacAddressCount
+ Unsigned32
+ }
+
+ hh3cEntityExtManuPhysicalIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of hh3cEntityExtManuTable.
+ This index is identical to entPhysicalIndex in ENTITY-MIB."
+ ::= { hh3cEntityExtManuEntry 1 }
+
+ hh3cEntityExtManuSerialNum OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacture serial number.
+ The manufacture serial number of the entity such as chassis,
+ module, and so on. It is got from the device when manufacturing.
+ For low level box-device, the manufacture serial number is the
+ device-number of System Control Board(SCB for short), it is written
+ into the SCB directly; for middle level or high level frame-device,
+ the manufacture serial number is the device-numbers of SCB and
+ Service Board, because the SCB, Service Board and chassis are
+ separate to sale and the device-number of chassis cannot be
+ written into board."
+ ::= { hh3cEntityExtManuEntry 2 }
+
+ hh3cEntityExtManuBuildInfo OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device version information.
+ The device version information of the entity such as chassis,
+ module, and so on. It consists of software version information
+ and hardware version information."
+ ::= { hh3cEntityExtManuEntry 3 }
+
+ hh3cEntityExtManuBOM OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Device BOM code.
+ The device BOM code of the entity such as chassis, module, and so
+ on. It is the component code of ERP system, which can be
+ disassembled from device-number."
+ ::= { hh3cEntityExtManuEntry 4 }
+
+ hh3cEntityExtMacAddressCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MAC address count.
+ The count of MAC addresses of the entity, such as chassis, module,
+ or port, and so on."
+ ::= { hh3cEntityExtManuEntry 5 }
+
+ hh3cEntityExtPower OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 3 }
+
+ hh3cEntityExtPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cEntityExtPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table describes the power information of all the physical
+ entity on the device, such as the fans, the subcards, the boards,
+ etc."
+ ::= { hh3cEntityExtPower 1 }
+
+ hh3cEntityExtPowerEntry OBJECT-TYPE
+ SYNTAX Hh3cEntityExtPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entity power information about a particular physical entity."
+ INDEX { hh3cEntityExtPowerPhysicalIndex }
+ ::= { hh3cEntityExtPowerTable 1 }
+
+ Hh3cEntityExtPowerEntry ::= SEQUENCE {
+ hh3cEntityExtPowerPhysicalIndex
+ Integer32,
+ hh3cEntityExtNominalPower
+ Gauge32,
+ hh3cEntityExtCurrentPower
+ Gauge32,
+ hh3cEntityExtAveragePower
+ Integer32,
+ hh3cEntityExtPeakPower
+ Integer32
+ }
+
+ hh3cEntityExtPowerPhysicalIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of hh3cEntityExtPowerTable.
+ This index is identical to entPhysicalIndex in ENTITY-MIB."
+ ::= { hh3cEntityExtPowerEntry 1 }
+
+ hh3cEntityExtNominalPower OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal power of the entity expressed in milliWatts."
+ ::= { hh3cEntityExtPowerEntry 2 }
+
+ hh3cEntityExtCurrentPower OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The measured usage power of the entity expressed in milliWatts."
+ ::= { hh3cEntityExtPowerEntry 3 }
+
+ hh3cEntityExtAveragePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The average power consumed by the entity expressed in milliWatts.
+ Writing a value of zero to this object resets its value to zero.
+ Writing any other value to this object has no effect on its value
+ and an error is returned."
+ ::= { hh3cEntityExtPowerEntry 4 }
+
+ hh3cEntityExtPeakPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The peak power consumed by the entity expressed in milliWatts.
+ Writing a value of zero to this object resets its value to zero.
+ Writing any other value to this object has no effect on its value
+ and an error is returned."
+ ::= { hh3cEntityExtPowerEntry 5 }
+
+-- Process Table
+ hh3cProcessObjects OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 4 }
+
+ hh3cProcessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Table describes the information about a particular process,
+ namely a task."
+ ::= { hh3cProcessObjects 1 }
+
+ hh3cProcessEntry OBJECT-TYPE
+ SYNTAX Hh3cProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The information about a particular process, namely a task."
+ INDEX { hh3cProcessID }
+ ::= { hh3cProcessTable 1 }
+
+ Hh3cProcessEntry ::= SEQUENCE {
+ hh3cProcessID Unsigned32,
+ hh3cProcessName DisplayString,
+ hh3cProcessUtil5Min Unsigned32
+ }
+
+ hh3cProcessID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the identifier of process, namely task ID
+ in system."
+ ::= { hh3cProcessEntry 1 }
+
+ hh3cProcessName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(1..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the process name."
+ ::= { hh3cProcessEntry 2 }
+
+ hh3cProcessUtil5Min OBJECT-TYPE
+ SYNTAX Unsigned32(0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object provides a general idea of how busy a process caused
+ the processor to be over a 5 minute period. The ratio is calculated
+ by the overall CPU usage caused by the process."
+ ::= { hh3cProcessEntry 3 }
+
+ hh3cEntityExtVoltageObjects OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 5 }
+
+ hh3cEntityExtVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cEntityExtVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table describes the voltage information of the voltage sensor
+ entities on the device."
+ ::= { hh3cEntityExtVoltageObjects 1 }
+
+ hh3cEntityExtVoltageEntry OBJECT-TYPE
+ SYNTAX Hh3cEntityExtVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The voltage information of the voltage sensor entity."
+ INDEX { hh3cEntityExtPhysicalIndex }
+ ::= { hh3cEntityExtVoltageTable 1 }
+
+ Hh3cEntityExtVoltageEntry ::= SEQUENCE {
+ hh3cEntityExtCurrentVoltage
+ Integer32,
+ hh3cEntityExtNominalVoltage
+ Integer32,
+ hh3cEntityExtVoltageState
+ INTEGER,
+ hh3cEntityExtVoltageMajorLowThreshold
+ Integer32,
+ hh3cEntityExtVoltageFatalLowThreshold
+ Integer32,
+ hh3cEntityExtVoltageMajorHighThreshold
+ Integer32,
+ hh3cEntityExtVoltageFatalHighThreshold
+ Integer32
+ }
+
+ hh3cEntityExtCurrentVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current voltage in millivolts of the voltage
+ sensor entity."
+ ::= { hh3cEntityExtVoltageEntry 1 }
+
+ hh3cEntityExtNominalVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal voltage in millivolts of the voltage
+ sensor entity."
+ ::= { hh3cEntityExtVoltageEntry 2 }
+
+ hh3cEntityExtVoltageState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ normal (0),
+ low (1),
+ tooLow (2),
+ high (3),
+ tooHigh (4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage state of the voltage sensor entity."
+ ::= { hh3cEntityExtVoltageEntry 3 }
+
+ hh3cEntityExtVoltageMajorLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The low threshold for the voltage sensor entity.
+
+ When the voltage is lower than the threshold, a notification
+ will be sent."
+ ::= { hh3cEntityExtVoltageEntry 4 }
+
+ hh3cEntityExtVoltageFatalLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The fatal low voltage threshold for the voltage sensor entity.
+
+ When the voltage is lower than the threshold, a notification
+ will be sent."
+ ::= { hh3cEntityExtVoltageEntry 5 }
+
+ hh3cEntityExtVoltageMajorHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The high threshold for the voltage sensor entity.
+
+ When the voltage is higher than the threshold, a notification
+ will be sent."
+ ::= { hh3cEntityExtVoltageEntry 6 }
+
+ hh3cEntityExtVoltageFatalHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The fatal high threshold for the voltage sensor entity.
+
+ When the voltage is higher than the threshold, a notification
+ will be sent."
+ ::= { hh3cEntityExtVoltageEntry 7 }
+
+-- End
+
+ hh3cEntityExtTraps OBJECT IDENTIFIER ::= { hh3cEntityExtend 2 }
+
+ hh3cEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { hh3cEntityExtTraps 0 }
+ hh3cEntityExtTrapsInfor OBJECT IDENTIFIER ::= { hh3cEntityExtTraps 1 }
+
+ hh3cEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtTemperatureThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtTemperatureThresholdNotification
+ indicates the temperature exceeded the threshold.
+ In this condition, user should check the status and the
+ environment of the entity, sometimes it happens because
+ of the failure of air-condition."
+ ::= { hh3cEntityExtTrapsPrefix 1 }
+
+ hh3cEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtVoltage,
+ hh3cEntityExtVoltageLowThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtVoltageLowThresholdNotification indicates
+ the voltage is lower than the threshold.
+
+ If the voltage is lower too much than the entity needs,
+ the entity will halt."
+ ::= { hh3cEntityExtTrapsPrefix 2 }
+
+ hh3cEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtVoltage,
+ hh3cEntityExtVoltageHighThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtVoltageHighThresholdNotification indicates
+ the voltage is higher than the threshold.
+
+ If the voltage is higher too much than the entity needs,
+ The entity may be damaged by the high voltage."
+ ::= { hh3cEntityExtTrapsPrefix 3 }
+
+ hh3cEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCpuUsage,
+ hh3cEntityExtCpuUsageThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtCpuUsageRecoverThreshold,
+ hh3cEntityExtFirstTrapTime
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtCpuUsageThresholdNotfication indicates
+ the entity is overloaded."
+ ::= { hh3cEntityExtTrapsPrefix 4 }
+
+ hh3cEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtMemUsage,
+ hh3cEntityExtMemUsageThreshold,
+ hh3cEntityExtMemSize,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtFirstTrapTime
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtMemUsageThresholdNotification indicates
+ the entity is overloaded."
+ ::= { hh3cEntityExtTrapsPrefix 5 }
+
+ hh3cEntityExtOperEnabled NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the entity is operable at present."
+ ::= { hh3cEntityExtTrapsPrefix 6 }
+
+ hh3cEntityExtOperDisabled NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the entity is not operable at present."
+ ::= { hh3cEntityExtTrapsPrefix 7 }
+
+ hh3cEntityExtCriticalTemperatureThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtCriticalTemperatureThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtCriticalTemperatureThresholdNotification
+ indicates the temperature exceeds the critical temperature.
+ In this condition, user should check the status and the
+ environment of the entity, sometimes it happens because
+ of the failure of air-condition."
+ ::= { hh3cEntityExtTrapsPrefix 8 }
+
+ hh3cEntityExtSFPAlarmOn NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtErrorStatus,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the SFP module fails
+ or runs abnormally for some particular reason."
+ ::= { hh3cEntityExtTrapsPrefix 9 }
+
+ hh3cEntityExtSFPAlarmOff NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtErrorStatus,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the SFP module restores to
+ normal status."
+ ::= { hh3cEntityExtTrapsPrefix 10 }
+
+ hh3cEntityExtSFPPhony NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "This module is NOT sold by authorized manufacturer.
+ The normal function of the device or assume the maintenance
+ responsibility thereof will NOT be guaranteed.
+ The trap is generated periodically after a phony module has been
+ found."
+ ::= { hh3cEntityExtTrapsPrefix 11 }
+
+ hh3cEntityInsert NOTIFICATION-TYPE
+ OBJECTS { entPhysicalDescr, hh3cEntityExtAdminStatus, hh3cEntityExtOperStatus }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when a removable entity inserting to
+ device."
+ ::= { hh3cEntityExtTrapsPrefix 12 }
+
+ hh3cEntityRemove NOTIFICATION-TYPE
+ OBJECTS { entPhysicalDescr, hh3cEntityExtAdminStatus, hh3cEntityExtOperStatus }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when a removable entity removing from
+ device."
+ ::= { hh3cEntityExtTrapsPrefix 13 }
+
+ hh3cEntityExtForcedPowerOff NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the entity is forced to power off."
+ ::= { hh3cEntityExtTrapsPrefix 14 }
+
+ hh3cEntityExtForcedPowerOn NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the entity is forced to power on."
+ ::= { hh3cEntityExtTrapsPrefix 15 }
+
+ hh3cEntityExtFaultAlarmOn NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtErrorStatus,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates a fault occurs on the specified entity."
+ ::= { hh3cEntityExtTrapsPrefix 16 }
+
+ hh3cEntityExtFaultAlarmOff NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtErrorStatus,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates a fault disappears on the specified entity."
+ ::= { hh3cEntityExtTrapsPrefix 17 }
+
+ hh3cEntityExtResourceLack NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates that a kind of resource is not enough on the
+ specified entity."
+ ::= { hh3cEntityExtTrapsPrefix 18 }
+
+ hh3cEntityExtResourceEnough NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates that the entity recovers from the status of no
+ enough resource."
+ ::= { hh3cEntityExtTrapsPrefix 19 }
+
+ hh3cEntityExtTemperatureLower NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtLowerTemperatureThreshold,
+ hh3cEntityExtAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the temperature of a specified entity is under
+ the lower threshold. In this condition, user should check the
+ status and the environment of the entity, sometimes it goes wrong
+ for some reason."
+ ::= { hh3cEntityExtTrapsPrefix 20 }
+
+ hh3cEntityExtTemperatureTooUp NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtShutdownTemperatureThreshold,
+ hh3cEntityExtAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the temperature of a specified entity exceeded
+ the shutdown threshold. In this condition, user should check the
+ status and the environment of the entity, sometimes it goes wrong
+ for some reason."
+ ::= { hh3cEntityExtTrapsPrefix 21 }
+
+ hh3cEntityExtTemperatureNormal NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtLowerTemperatureThreshold,
+ hh3cEntityExtTemperatureThreshold,
+ hh3cEntityExtAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the temperature of a specified entity recover
+ from abnormal status."
+ ::= { hh3cEntityExtTrapsPrefix 22 }
+
+ hh3cEntityExternalAlarmOccur NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the monitored device connected to the
+ specified entity fails."
+ ::= { hh3cEntityExtTrapsPrefix 23 }
+
+ hh3cEntityExternalAlarmRecover NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the failed device connected to the
+ specified entity returns to normal."
+ ::= { hh3cEntityExtTrapsPrefix 24 }
+
+ hh3cEntityExtCpuUsageThresholdRecover NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCpuUsage,
+ hh3cEntityExtCpuUsageThreshold,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtCpuUsageRecoverThreshold,
+ hh3cEntityExtFirstTrapTime
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the CPU usage descends the threshold."
+ ::= { hh3cEntityExtTrapsPrefix 25 }
+
+ hh3cEntityExtMemUsageThresholdRecover NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtMemUsage,
+ hh3cEntityExtMemUsageThreshold,
+ hh3cEntityExtMemSize,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtFirstTrapTime
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the memory usage descends the threshold."
+ ::= { hh3cEntityExtTrapsPrefix 26 }
+
+ hh3cEntityExtMemAllocatedFailed NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtTrapDescription
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the memory allocated failed."
+ ::= { hh3cEntityExtTrapsPrefix 27 }
+
+ hh3cEntityExtECCParityAlarm NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtECCParityAlarmStatus,
+ hh3cEntityExtTrapDescription
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap indicates the ECC(Error Correction Code) parity error alarm."
+ ::= { hh3cEntityExtTrapsPrefix 28 }
+
+ hh3cEntityExtCritLowerTempThresholdNotification NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtCriticalLowerTemperatureThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtCritLowerTempThresholdNotification
+ indicates the temperature is lower than the threshold.
+
+ If the temperature is lower too much than the entity needs,
+ the entity will halt."
+ ::= { hh3cEntityExtTrapsPrefix 29 }
+
+ hh3cEntityExtTemperatureTooLow NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtShutdownLowerTemperatureThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "The hh3cEntityExtTemperatureTooLow indicates the temperature
+ is lower than the threshold.
+
+ If the temperature is lower too much than the entity needs,
+ the entity halts now."
+ ::= { hh3cEntityExtTrapsPrefix 30 }
+
+ hh3cEntityExtFanDirectionNotPreferred NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates the specified fan's direction does not
+ accord with preferred. The two parameters indicate the entity
+ index and physical name of fan."
+ ::= { hh3cEntityExtTrapsPrefix 31 }
+
+ hh3cEntityExtFanDirectionNotAccord NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates the direction of fans does not accord
+ with each other. The two parameters indicate the parent
+ entity of the fans."
+ ::= { hh3cEntityExtTrapsPrefix 32 }
+
+ hh3cEntityExtSFPInvalid NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtSFPInvalidInDays
+ }
+ STATUS current
+ DESCRIPTION
+ "The transceiver module is not compatible with the interface card.
+ The authorized manufacturer therefore shall NOT guarantee
+ the normal function of the transceiver.
+ The transceiver module will be invalidated in days.
+ Please replace it with a compatible one as soon as possible.
+ The trap is generated periodically after a phony transceiver module
+ has been found."
+ ::= { hh3cEntityExtTrapsPrefix 33 }
+
+ hh3cEntityExtSFPInvalidNow NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName
+ }
+ STATUS current
+ DESCRIPTION
+ "This transceiver module is not compatible with the interface card.
+ The authorized manufacturer therefore shall NOT guarantee
+ the normal function of the transceiver.
+ The trap is generated after a phony transceiver module
+ has been found."
+ ::= { hh3cEntityExtTrapsPrefix 34 }
+
+ hh3cEntityExtMemUsageThresholdOverTrap NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtMemUsage,
+ hh3cEntityExtMemUsageThreshold,
+ hh3cEntityExtMemSizeRev,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the memory usage of the entity is
+ overloaded.
+
+ This trap is used to replace
+ hh3cEntityExtMemUsageThresholdNotification."
+ ::= { hh3cEntityExtTrapsPrefix 35 }
+
+ hh3cEntityExtMemUsageThresholdRecoverTrap NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtMemUsage,
+ hh3cEntityExtMemUsageThreshold,
+ hh3cEntityExtMemSizeRev,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the memory usage decreased below
+ the threshold.
+
+ This trap is used to replace
+ hh3cEntityExtMemUsageThresholdRecover."
+ ::= { hh3cEntityExtTrapsPrefix 36 }
+
+ hh3cEntityExtVoltageNormal NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCurrentVoltage,
+ hh3cEntityExtNominalVoltage,
+ hh3cEntityExtVoltageMajorLowThreshold,
+ hh3cEntityExtVoltageMajorHighThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the voltage recovers to normal."
+ ::= { hh3cEntityExtTrapsPrefix 37 }
+
+ hh3cEntityExtVoltageLower NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCurrentVoltage,
+ hh3cEntityExtNominalVoltage,
+ hh3cEntityExtVoltageMajorLowThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the voltage is lower than the
+ low threshold."
+ ::= { hh3cEntityExtTrapsPrefix 38 }
+
+ hh3cEntityExtVoltageTooLow NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCurrentVoltage,
+ hh3cEntityExtNominalVoltage,
+ hh3cEntityExtVoltageFatalLowThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the voltage is lower than the
+ fatal low threshold."
+ ::= { hh3cEntityExtTrapsPrefix 39 }
+
+ hh3cEntityExtVoltageHigher NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCurrentVoltage,
+ hh3cEntityExtNominalVoltage,
+ hh3cEntityExtVoltageMajorHighThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the voltage is higher than the
+ high threshold."
+ ::= { hh3cEntityExtTrapsPrefix 40 }
+
+ hh3cEntityExtVoltageTooHigh NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtCurrentVoltage,
+ hh3cEntityExtNominalVoltage,
+ hh3cEntityExtVoltageFatalHighThreshold
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the voltage is higher than the
+ fatal high threshold."
+ ::= { hh3cEntityExtTrapsPrefix 41 }
+
+ hh3cEntityExtSFPAlarmOnEx NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtErrorStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the SFP module fails
+ or runs abnormally for some particular reason.
+ This trap is used to replace hh3cEntityExtSFPAlarmOn."
+ ::= { hh3cEntityExtTrapsPrefix 42 }
+
+ hh3cEntityExtSFPAlarmOffEx NOTIFICATION-TYPE
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ entPhysicalName,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtErrorStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The trap is generated when the SFP module is restored to
+ normal status.
+ This trap is used to replace hh3cEntityExtSFPAlarmOff."
+ ::= { hh3cEntityExtTrapsPrefix 43 }
+
+ hh3cEntityExtTrapDescription OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..255))
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The information of trap."
+ ::= { hh3cEntityExtTrapsInfor 1 }
+
+ hh3cEntityExtECCParityAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ l1cache(2), -- cpu l1 data cache err
+ l2cache(3), -- cpu l2 data cache err
+ sdram(4), -- sdram err for cpu
+ mac(5), -- mac err
+ tcam(6), -- tcam err
+ ingressbuffer(7), -- IB err
+ egressbuffer(8), -- EB err
+ lpm(9), -- lpm err
+ controlmemory(10) -- controlmemory err
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "ECC parity error."
+ ::= { hh3cEntityExtTrapsInfor 2 }
+
+ hh3cEntityExtSFPInvalidInDays OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The days when the transceiver module is still valid,
+ but after those days, it will be invalidated."
+ ::= { hh3cEntityExtTrapsInfor 3 }
+
+ hh3cEntityExtFirstTrapTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Represents the first trap time."
+ ::= { hh3cEntityExtTrapsInfor 4 }
+
+-- Conformance and Compliance
+ hh3cEntityExtConformance OBJECT IDENTIFIER ::= { hh3cEntityExtend 3 }
+
+ hh3cEntityExtCompliances OBJECT IDENTIFIER ::= { hh3cEntityExtConformance 1 }
+
+-- this module
+ hh3cEntityExtCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for systems supporting this MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS { hh3cEntityExtGroup, hh3cEntityExtNotificationGroup,
+ hh3cEntityExtManuGroup, hh3cEntityExtPowerGroup }
+ OBJECT hh3cEntityExtAdminStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ OBJECT hh3cEntityExtCpuUsageThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ OBJECT hh3cEntityExtMemUsageThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ OBJECT hh3cEntityExtTemperatureThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ OBJECT hh3cEntityExtVoltageLowThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ OBJECT hh3cEntityExtVoltageHighThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { hh3cEntityExtCompliances 1 }
+
+ hh3cEntityExtGroups OBJECT IDENTIFIER ::= { hh3cEntityExtConformance 2 }
+
+ hh3cEntityExtGroup OBJECT-GROUP
+ OBJECTS {
+ hh3cEntityExtPhysicalIndex,
+ hh3cEntityExtAdminStatus,
+ hh3cEntityExtOperStatus,
+ hh3cEntityExtStandbyStatus,
+ hh3cEntityExtAlarmLight,
+ hh3cEntityExtCpuUsage,
+ hh3cEntityExtCpuUsageThreshold,
+ hh3cEntityExtMemUsage,
+ hh3cEntityExtMemUsageThreshold,
+ hh3cEntityExtMemSize,
+ hh3cEntityExtUpTime,
+ hh3cEntityExtTemperature,
+ hh3cEntityExtTemperatureThreshold,
+ hh3cEntityExtVoltage,
+ hh3cEntityExtVoltageLowThreshold,
+ hh3cEntityExtVoltageHighThreshold,
+ hh3cEntityExtCriticalTemperatureThreshold,
+ hh3cEntityExtMacAddress,
+ hh3cEntityExtErrorStatus,
+ hh3cEntityExtCpuMaxUsage,
+ hh3cEntityExtLowerTemperatureThreshold,
+ hh3cEntityExtShutdownTemperatureThreshold,
+ hh3cEntityExtPhyMemSize,
+ hh3cEntityExtPhyCpuFrequency,
+ hh3cEntityExtFirstUsedDate,
+ hh3cEntityExtCpuAvgUsage,
+ hh3cEntityExtMemAvgUsage,
+ hh3cEntityExtMemType,
+ hh3cEntityExtCriticalLowerTemperatureThreshold,
+ hh3cEntityExtShutdownLowerTemperatureThreshold,
+ hh3cEntityExtCpuUsageRecoverThreshold,
+ hh3cEntityExtMemSizeRev,
+ hh3cEntityExtCpuUsageIn1Minute,
+ hh3cEntityExtCpuUsageIn5Minutes
+ }
+ STATUS current
+ DESCRIPTION
+ "Entity Extend group."
+ ::= { hh3cEntityExtGroups 1 }
+
+ hh3cEntityExtNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { hh3cEntityExtTemperatureThresholdNotification,
+ hh3cEntityExtVoltageLowThresholdNotification,
+ hh3cEntityExtVoltageHighThresholdNotification,
+ hh3cEntityExtCpuUsageThresholdNotfication,
+ hh3cEntityExtMemUsageThresholdNotification,
+ hh3cEntityExtOperEnabled,
+ hh3cEntityExtOperDisabled,
+ hh3cEntityExtCriticalTemperatureThresholdNotification,
+ hh3cEntityExtSFPAlarmOn,
+ hh3cEntityExtSFPAlarmOff,
+ hh3cEntityExtSFPPhony,
+ hh3cEntityInsert,
+ hh3cEntityRemove,
+ hh3cEntityExtForcedPowerOff,
+ hh3cEntityExtForcedPowerOn,
+ hh3cEntityExtFaultAlarmOn,
+ hh3cEntityExtFaultAlarmOff,
+ hh3cEntityExtResourceLack,
+ hh3cEntityExtResourceEnough,
+ hh3cEntityExtTemperatureLower,
+ hh3cEntityExtTemperatureTooUp,
+ hh3cEntityExtTemperatureNormal,
+ hh3cEntityExternalAlarmOccur,
+ hh3cEntityExternalAlarmRecover,
+ hh3cEntityExtCpuUsageThresholdRecover,
+ hh3cEntityExtMemUsageThresholdRecover,
+ hh3cEntityExtMemAllocatedFailed,
+ hh3cEntityExtECCParityAlarm,
+ hh3cEntityExtCritLowerTempThresholdNotification,
+ hh3cEntityExtTemperatureTooLow,
+ hh3cEntityExtFanDirectionNotPreferred,
+ hh3cEntityExtFanDirectionNotAccord,
+ hh3cEntityExtSFPInvalid,
+ hh3cEntityExtSFPInvalidNow,
+ hh3cEntityExtMemUsageThresholdOverTrap,
+ hh3cEntityExtMemUsageThresholdRecoverTrap,
+ hh3cEntityExtVoltageNormal,
+ hh3cEntityExtVoltageTooLow,
+ hh3cEntityExtVoltageLower,
+ hh3cEntityExtVoltageHigher,
+ hh3cEntityExtVoltageTooHigh,
+ hh3cEntityExtSFPAlarmOnEx,
+ hh3cEntityExtSFPAlarmOffEx
+ }
+ STATUS current
+ DESCRIPTION
+ "Entity Extend Notification group."
+ ::= { hh3cEntityExtGroups 2 }
+
+ hh3cEntityExtManuGroup OBJECT-GROUP
+ OBJECTS {
+ hh3cEntityExtManuPhysicalIndex,
+ hh3cEntityExtManuSerialNum,
+ hh3cEntityExtManuBuildInfo,
+ hh3cEntityExtManuBOM,
+ hh3cEntityExtMacAddressCount
+ }
+ STATUS current
+ DESCRIPTION
+ "Standard Device Manufacture Information group."
+ ::= { hh3cEntityExtGroups 3 }
+
+ hh3cEntityExtPowerGroup OBJECT-GROUP
+ OBJECTS {
+ hh3cEntityExtPowerPhysicalIndex,
+ hh3cEntityExtNominalPower,
+ hh3cEntityExtCurrentPower,
+ hh3cEntityExtAveragePower,
+ hh3cEntityExtPeakPower
+ }
+ STATUS current
+ DESCRIPTION
+ "Standard Entity Power Information group."
+ ::= { hh3cEntityExtGroups 4 }
+
+ END