summaryrefslogtreecommitdiff
path: root/MIBS/comtrol
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/comtrol
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/comtrol')
-rw-r--r--MIBS/comtrol/ES8510-MIB6868
1 files changed, 6868 insertions, 0 deletions
diff --git a/MIBS/comtrol/ES8510-MIB b/MIBS/comtrol/ES8510-MIB
new file mode 100644
index 0000000..a35256e
--- /dev/null
+++ b/MIBS/comtrol/ES8510-MIB
@@ -0,0 +1,6868 @@
+COMTROL-ES8510-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ internet FROM RFC1155-SMI
+ RowStatus, DisplayString, MacAddress, TimeInterval FROM SNMPv2-TC
+ PortList FROM Q-BRIDGE-MIB;
+
+
+private OBJECT IDENTIFIER ::= { internet 4 }
+enterprises OBJECT IDENTIFIER ::= { private 1 }
+comtrol OBJECT IDENTIFIER ::= { enterprises 2882 }
+products OBJECT IDENTIFIER ::= { comtrol 2 }
+managedSwitch OBJECT IDENTIFIER ::= { products 1 }
+es8510 OBJECT IDENTIFIER ::= { managedSwitch 1 }
+
+contact MODULE-IDENTITY
+ LAST-UPDATED "201805140000Z"
+ ORGANIZATION "Comtrol Corporation"
+ CONTACT-INFO "Comtrol Corporation"
+ DESCRIPTION "Comtrol Corporation
+ 100 Fifth Avenue NW
+ New Brighton, MN 55112
+ TEL: +1.763.957.6000
+ E-mail: ftpadmin@comtrol.com"
+ REVISION "201805140000Z"
+ DESCRIPTION "version 3.1a"
+ ::= { comtrol 1 }
+
+systemInfo OBJECT IDENTIFIER ::= { es8510 1 }
+basicSetting OBJECT IDENTIFIER ::= { es8510 2 }
+portConfiguration OBJECT IDENTIFIER ::= { es8510 3 }
+networkRedundancy OBJECT IDENTIFIER ::= { es8510 4 }
+vlan OBJECT IDENTIFIER ::= { es8510 5 }
+trafficPrioritization OBJECT IDENTIFIER ::= { es8510 6 }
+multicastFiltering OBJECT IDENTIFIER ::= { es8510 7 }
+snmp OBJECT IDENTIFIER ::= { es8510 8 }
+security OBJECT IDENTIFIER ::= { es8510 9 }
+warning OBJECT IDENTIFIER ::= { es8510 10 }
+monitorandDiag OBJECT IDENTIFIER ::= { es8510 11 }
+save OBJECT IDENTIFIER ::= { es8510 12 }
+
+
+-- -----------------------------------------------------------------------------
+-- Textual Convention
+-- -----------------------------------------------------------------------------
+AlertType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION ""
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+
+-- -----------------------------------------------------------------------------
+-- systemInfo
+-- -----------------------------------------------------------------------------
+systemName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-only
+ STATUS current
+ DESCRIPTION "An administratively-assigned name for this managed node.
+ By convention, this is the node's fully-qualified domain name."
+ ::= { systemInfo 1 }
+
+systemLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-only
+ STATUS current
+ DESCRIPTION "The physical location of this node (e.g., telephone closet,
+ 3rd floor')."
+ ::= { systemInfo 2 }
+
+systemContact OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The textual identification of the contact person for this
+ managed node, together with information on how to contact
+ this person."
+ ::= { systemInfo 3 }
+
+systemDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-only
+ STATUS current
+ DESCRIPTION "A textual description of the entity. This value should
+ include the full name and version identification of the
+ system's hardware type, software operating-system, and
+ networking software. It is mandatory that this only contain
+ printable ASCII characters."
+ ::= { systemInfo 4 }
+
+systemFwVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Firmware version of the device."
+ ::= { systemInfo 5 }
+
+systemMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The MAC address of this device. An Media Access Control
+ address (MAC address) is a unique identifier attached to
+ most network adapters (NICs). It is a number that acts
+ like a name for a particular network adapter"
+ ::= { systemInfo 6 }
+
+-- -----------------------------------------------------------------------------
+-- basicSetting
+-- -----------------------------------------------------------------------------
+
+switchSetting OBJECT IDENTIFIER ::= { basicSetting 1 }
+adminPassword OBJECT IDENTIFIER ::= { basicSetting 2 }
+ipConfiguration OBJECT IDENTIFIER ::= { basicSetting 3 }
+timeSetting OBJECT IDENTIFIER ::= { basicSetting 4 }
+dhcpServer OBJECT IDENTIFIER ::= { basicSetting 5 }
+backupAndRestore OBJECT IDENTIFIER ::= { basicSetting 6 }
+tftpUpgrade OBJECT IDENTIFIER ::= { basicSetting 7 }
+factoryDefault OBJECT IDENTIFIER ::= { basicSetting 8 }
+systemReboot OBJECT IDENTIFIER ::= { basicSetting 9 }
+
+-- -----------------------------------------------------------------------------
+-- switchSetting
+-- -----------------------------------------------------------------------------
+
+switchSettingSystemName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..256))
+ ACCESS read-write
+ STATUS current
+ DESCRIPTION "An administratively-assigned name for this managed node. By
+ convention, this is the node's fully-qualified domain name."
+ ::= { switchSetting 1 }
+
+switchSettingSystemLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..256))
+ ACCESS read-write
+ STATUS current
+ DESCRIPTION "The physical location of this node (e.g., telephone closet,
+ 3rd floor')."
+ ::= { switchSetting 2 }
+
+switchSettingSystemContact OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..256))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The textual identification of the contact person for this
+ managed node, together with information on how to contact
+ this person."
+ ::= { switchSetting 3 }
+
+-- -----------------------------------------------------------------------------
+-- adminPassword
+-- -----------------------------------------------------------------------------
+
+adminPasswordUserName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The name(ID) of security manager."
+ ::= { adminPassword 1 }
+
+adminPasswordPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..8))
+ MAX-ACCESS write-only
+ STATUS current
+ DESCRIPTION "The password of security manager.
+ This object can't be read. it's write-only."
+ ::= { adminPassword 2 }
+
+--adminPasswordConfirm OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..8))
+-- MAX-ACCESS write-only
+-- STATUS current
+-- DESCRIPTION "To confirm the password modification.
+-- This object can't be read. it's write-only."
+-- ::= { adminPassword 3 }
+
+-- -----------------------------------------------------------------------------
+-- ipConfiguration
+-- -----------------------------------------------------------------------------
+ipConfigurationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IPconfigurationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ the IP of the device."
+ ::= { ipConfiguration 1 }
+
+ipConfigurationEntry OBJECT-TYPE
+ SYNTAX IPconfigurationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring static IP or DHCP configuration
+ of the device."
+ INDEX { ipConfigurationIndex }
+ ::= { ipConfigurationTable 1 }
+
+IPconfigurationEntry ::= SEQUENCE {
+ ipConfigurationIndex INTEGER,
+ ipConfigurationDHCPStatus INTEGER,
+ ipConfigurationAddress IpAddress,
+ ipConfigurationSubMask IpAddress,
+ ipConfigurationGateway IpAddress,
+ ipConfigurationDNS1 IpAddress,
+ ipConfigurationDNS2 IpAddress,
+ ipConfigurationStatus INTEGER
+}
+
+ipConfigurationIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "This object identifies IP configuration entries."
+ ::= { ipConfigurationEntry 1 }
+
+
+ipConfigurationDHCPStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter configuring DHCP client functionality of the
+ device. When enabled, device will be a DHCP client and
+ request for the IP configuration from DHCP server.
+
+ The Dynamic Host Configuration Protocol (DHCP) automates
+ the assignment of IP addresses, subnet masks, default
+ routers, and other IP parameters. The assignment usually
+ occurs when the DHCP-configured machine boots up or regains
+ connectivity to the network. The DHCP client sends out a
+ query requesting a response from a DHCP server on the
+ locally attached network. The query is typically initiated
+ immediately after booting up and before the client initiates
+ any IP based communication with other hosts. The DHCP server
+ then replies to the client with its assigned IP address,
+ subnet mask, DNS server and default gateway information.
+
+ Note: Other items in this table will not be modified, when
+ ipConfigurationDHCPStatus is enabled."
+ ::= { ipConfigurationEntry 2 }
+
+ipConfigurationAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of switch.
+ An IP address (Internet Protocol address) is a unique address
+ that devices use in order to identify and communicate with
+ each other on a computer network utilizing the Internet
+ Protocol standard (IP). Any participating network device can
+ has its own unique address."
+ ::= { ipConfigurationEntry 3 }
+
+ipConfigurationSubMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The subnet mask is a 32-bit number in the same format and
+ representation as IP addresses. The subnet mask determines
+ which bits in the IP address are interpreted as the network
+ number, which as the subnetwork number, and which as the
+ host number. Each IP address bit that corresponds to a 1
+ in the subnet mask is in the network/subnetwork part of
+ the address. This group of numbers is also called the
+ Network ID. Each IP address bit that corresponds to a 0 is
+ in the host part of the IP address."
+ ::= { ipConfigurationEntry 4 }
+
+ipConfigurationGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default gateway IP address identifies the gateway (for
+ example, a router) that receives and forwards those packets
+ whose addresses are unknown to the local network. The agent
+ uses the default gateway address when sending alert packets
+ to the management workstation on a network other than the
+ local network."
+ ::= { ipConfigurationEntry 5 }
+
+ipConfigurationDNS1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter configuring the first DNS server of the device.
+
+ The domain name system (DNS) stores and associates many
+ types of information with domain names. Most importantly,
+ it translates domain names (computer hostnames) to IP
+ addresses, which makes it possible to attach easy-to-remember
+ domain names to hard-to-remember IP
+ addresses (such as 100.50.10.100)."
+ ::= { ipConfigurationEntry 6 }
+
+ipConfigurationDNS2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter configuring the second DNS server of the device."
+ ::= { ipConfigurationEntry 7 }
+
+ipConfigurationStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of the IP configuration entry. Only one
+ configuration entry is supported on the device. Set active(1)
+ to activate the parameters of the entry on the device."
+ ::= { ipConfigurationEntry 8 }
+
+-- -----------------------------------------------------------------------------
+-- timeSetting
+-- -----------------------------------------------------------------------------
+systemTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "current system time in format yyyy.mm.dd-hh:mm:ss"
+ ::= { timeSetting 1 }
+
+utcTimeZone OBJECT-TYPE
+ SYNTAX INTEGER {
+ gmtNegative1200EniwetokKwajalein(1),
+ gmtNegative1100MidwayIslandSamoa(2),
+ gmtNegative1000Hawaii(3),
+ gmtNegative0900Alaska(4),
+ gmtNegative0800PacificTimeUSandCanadaTijuana(5),
+ gmtNegative0700Arizona(6),
+ gmtNegative0700MountainTimeUSandCanada(7),
+ gmtNegative0600CentralAmerica(8),
+ gmtNegative0600CentralTimeUSandCanada(9),
+ gmtNegative0600MexicoCityTegucigalpa(10),
+ gmtNegative0600Saskatchewan(11),
+ gmtNegative0500BogotaLimaQuito(12),
+ gmtNegative0500EasternTimeUSandCanada(13),
+ gmtNegative0500IndianaEast(14),
+ gmtNegative0400AtlanticTimeCanada(15),
+ gmtNegative0400CaracasLaPaz(16),
+ gmtNegative0400Santiago(17),
+ gmtNegative0330Newfoundland(18),
+ gmtNegative0300Brasilia(19),
+ gmtNegative0300BuenosAiresGeorgetown(20),
+ gmtNegative0300Greenland(21),
+ gmtNegative0200Mid-Atlantic(22),
+ gmtNegative0100AzoresCapeVerdeIs(23),
+ gmtNegative0100CapeVerdeIs(24),
+ gmtCasablancaMonrovia(25),
+ gmtGreenwichMeanTimeDublinEdinburghLisbonLondon(26),
+ gmtPositive0100AmsterdamBerlinBernRomeStockholmVienna(27),
+ gmtPositive0100BelgradeBratislavaBudapestLjubljanaPrague(28),
+ gmtPositive0100BrusselsCopenhagenMadridParis(29),
+ gmtPositive0100SarajevoSkopjeSofijaWarsawZagreb(30),
+ gmtPositive0100WestCentralAfrica(31),
+ gmtPositive0200AthensIstanbulMinsk(32),
+ gmtPositive0200Bucharest(33),
+ gmtPositive0200Cairo(34),
+ gmtPositive0200HararePretoria(35),
+ gmtPositive0200HelsinkiRigaTallinn(36),
+ gmtPositive0200Jerusalem(37),
+ gmtPositive0300BaghdadKuwaitRiyadh(38),
+ gmtPositive0300KuwaitRiyadh(39),
+ gmtPositive0300MoscowStPetersburgVolgograd(40),
+ gmtPositive0300Mairobi(41),
+ gmtPositive0330Tehran(42),
+ gmtPositive0400AbuDhabiMuscat(43),
+ gmtPositive0400BakuTbilisi(44),
+ gmtPositive0430Kabul(45),
+ gmtPositive0500Ekaterinburg(46),
+ gmtPositive0500IslamabadKarachiTashkent(47),
+ gmtPositive0530BombayCalcuttaMadrasNewDelhi(48),
+ gmtPositive0545Kathmandu(49),
+ gmtPositive0600AlmatyNovosibirsk(50),
+ gmtPositive0600AstanaDhaka(51),
+ gmtPositive0600Colombo(52),
+ gmtPositive0630Rangoon(53),
+ gmtPositive0700BangkokHanoiJakarta(54),
+ gmtPositive0700Krasnoyarsk(55),
+ gmtPositive0800BeijingChongqingHongKongUrumqi(56),
+ gmtPositive0800IrkutskUlaanBataar(57),
+ gmtPositive0800KualaLumpurSingapore(58),
+ gmtPositive0800Perth(59),
+ gmtPositive0800Taipei(60),
+ gmtPositive0900OsakaSapporoTokyo(61),
+ gmtPositive0900Seoul(62),
+ gmtPositive0900Yakutsk(63),
+ gmtPositive0930Adelaide(64),
+ gmtPositive0930Darwin(65),
+ gmtPositive1000Brisbane(66),
+ gmtPositive1000CanberraMelbourneSydney(67),
+ gmtPositive1000GuamPortMoresby(68),
+ gmtPositive1000Hobart(69),
+ gmtPositive1000Vladivostok(70),
+ gmtPositive1100MagadanSolomonIsNewCaledonia(71),
+ gmtPositive1200AucklandWllington(72),
+ gmtPositive1200FijiKamchatkaMarshallIs(73),
+ gmtPositive1300Nukualofa(74)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "UTC Timezone list.
+ (GMT-12:00) Eniwetok, Kwajalein
+ (GMT-11:00) Midway Island, Samoa
+ (GMT-10:00) Hawaii
+ (GMT-09:00) Alaska
+ (GMT-08:00) Pacific Time (US & Canada), Tijuana
+ (GMT-07:00) Arizona
+ (GMT-07:00) Mountain Time (US & Canada)
+ (GMT-06:00) Central America
+ (GMT-06:00) Central Time (US & Canada)
+ (GMT-06:00) Mexico City
+ (GMT-06:00) Saskatchewan
+ (GMT-05:00) Bogota, Lima, Quito
+ (GMT-05:00) Eastern Time (US & Canada)
+ (GMT-05:00) Indiana (East)
+ (GMT-04:00) Atlantic Time (Canada)
+ (GMT-04:00) Caracas, La Paz
+ (GMT-04:00) Santiago
+ (GMT-03:00) NewFoundland
+ (GMT-03:00) Brasilia
+ (GMT-03:00) Buenos Aires, Georgetown
+ (GMT-03:00) Greenland
+ (GMT-02:00) Mid-Atlantic
+ (GMT-01:00) Azores
+ (GMT-01:00) Cape Verde Is.
+ (GMT) Casablanca, Monrovia
+ (GMT) Greenwich Mean Time: Dublin, Edinburgh, Lisbon, London
+ (GMT+01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna
+ (GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague
+ (GMT+01:00) Brussels, Copenhagen, Madrid, Paris
+ (GMT+01:00) Sarajevo, Skopje, Sofija, Vilnius, Warsaw, Zagreb
+ (GMT+01:00) West Central Africa
+ (GMT+02:00) Athens, Istanbul, Minsk
+ (GMT+02:00) Bucharest
+ (GMT+02:00) Cairo
+ (GMT+02:00) Harare, Pretoria
+ (GMT+02:00) Helsinki, Riga, Tallinn
+ (GMT+02:00) Jerusalem
+ (GMT+03:00) Baghdad
+ (GMT+03:00) Kuwait, Riyadh
+ (GMT+03:00) Moscow, St. Petersburg, Volgograd
+ (GMT+03:00) Nairobi
+ (GMT+03:30) Tehran
+ (GMT+04:00) Abu Dhabi, Muscat
+ (GMT+04:00) Baku, Tbilisi, Yerevan
+ (GMT+04:30) Kabul
+ (GMT+05:00) Ekaterinburg
+ (GMT+05:00) Islamabad, Karachi, Tashkent
+ (GMT+05:30) Calcutta, Chennai, Mumbai, New Delhi
+ (GMT+05:45) Kathmandu
+ (GMT+06:00) Almaty, Novosibirsk
+ (GMT+06:00) Astana, Dhaka
+ (GMT+06:00) Sri Jayawardenepura
+ (GMT+06:30) Rangoon
+ (GMT+07:00) Bangkok, Hanoi, Jakarta
+ (GMT+07:00) Krasnoyarsk
+ (GMT+08:00) Beijing, Chongqing, Hong Kong, Urumqi
+ (GMT+08:00) Irkutsk, Ulaan Bataar
+ (GMT+08:00) Kuala Lumpur, Singapore
+ (GMT+08:00) Perth
+ (GMT+08:00) Taipei
+ (GMT+09:00) Osaka, Sapporo, Tokyo
+ (GMT+09:00) Seoul
+ (GMT+09:00) Yakutsk
+ (GMT+09:30) Adelaide
+ (GMT+09:30) Darwin
+ (GMT+10:00) Brisbane
+ (GMT+10:00) Canberra, Melbourne, Sydney
+ (GMT+10:00) Guam, Port Moresby
+ (GMT+10:00) Hobart
+ (GMT+10:00) Vladivostok
+ (GMT+11:00) Magadan, Solomon Is., New Caledonia
+ (GMT+12:00) Aukland, Wellington
+ (GMT+12:00) Fiji, Kamchatka, Marshall Is.
+ (GMT+13:00) Nuku'alofa"
+ ::= { timeSetting 2 }
+
+dayLightSavingTime OBJECT IDENTIFIER ::= { timeSetting 3 }
+clockSource OBJECT IDENTIFIER ::= { timeSetting 4 }
+
+-- -----------------------------------------------------------------------------
+-- dayLightSavingTime
+-- -----------------------------------------------------------------------------
+daylightSavingTimeStart OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..12))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The start-time of daylight saveing period,
+ in format mm.n.d/hh:mm
+ m is month, valid range 1-12 (1=January, 2=February, ..., 12=December).
+ n is week of the month (1 to 5, 5 means the last week).
+ d is weekday, valid range 0-6 (0=Sunday, 1=Monday, ..., 6=Saturday).
+ hh:mm is time."
+ ::= { dayLightSavingTime 1 }
+
+daylightSavingTimeEnd OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..12))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The end-time of daylight saveing period,
+ in format mm.n.d/hh:mm
+ m is month, valid range 1-12 (1=January, 2=February, ..., 12=December).
+ n is week of the month (1 to 5, 5 means the last week).
+ d is weekday, valid range 0-6 (0=Sunday, 1=Monday, ..., 6=Saturday).
+ hh:mm is time."
+ ::= { dayLightSavingTime 2 }
+
+daylightSavingOffset OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Daylight Saving Offset(Usually is 60 mins).
+ When Enable and current time at Daylight Saving Period,
+ the current time of the switch will be offseted by
+ Daylight Saving Offset."
+ ::= { dayLightSavingTime 3 }
+
+daylightSavingTimeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)Enable Daylight Saving Time.
+ (2)Disable Daylight Saving Time.
+ Daylight Saving Time:
+ Use this OID to Enable/Disable Daylight Saving Time."
+ ::= { dayLightSavingTime 4 }
+
+-- -----------------------------------------------------------------------------
+-- clock source configuration
+-- -----------------------------------------------------------------------------
+clockSourceSelection OBJECT-TYPE
+ SYNTAX INTEGER {
+ manual(1),
+ ntp(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { clockSource 1 }
+
+clockSourceManual OBJECT IDENTIFIER ::= { clockSource 2 }
+clockSourceNtp OBJECT IDENTIFIER ::= { clockSource 3 }
+
+-- -----------------------------------------------------------------------------
+-- manual config
+-- -----------------------------------------------------------------------------
+clockSourceManualSetting OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..19))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "set system time, in format yyyy.mm.dd-hh:mm:ss"
+ ::= { clockSourceManual 1 }
+
+-- -----------------------------------------------------------------------------
+-- ntp
+-- -----------------------------------------------------------------------------
+
+--ntpClientStatus OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- enabled(1),
+-- disabled(2)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "(1)Enable SNTP clinet.
+-- (2)Disable SNTP clinet.
+-- SNTP is simple network time protocol.
+-- Use this OID to Enable/Disable SNTP client."
+-- ::= { ntp 1 }
+
+ntpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NtpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about NTP
+ servers.
+
+ NTP (Network Time Protocol) synchronizes timekeeping among a
+ set of distributed time servers and clients. This synchronization
+ allows events to be correlated when system logs are created and
+ other time-specific events occur.
+
+ An NTP server is configured to synchronize NTP clients. Servers
+ can be configured to synchronize any client or only specific
+ clients. NTP servers, however, will accept no synchronization
+ information from their clients and therefore will not let
+ clients update or affect the server's time settings.
+
+ This switch acts as an NTP client, which tries to let its clock
+ be set and synchronized by an external NTP timeserver. It can be
+ configured to use multiple servers (upto 4 servers)."
+ ::= { clockSourceNtp 1 }
+
+ntpEntry OBJECT-TYPE
+ SYNTAX NtpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring IP addresses of NTP servers."
+ INDEX { ntpIndex }
+ ::= { ntpTable 1 }
+
+NtpEntry ::= SEQUENCE {
+ ntpIndex Integer32,
+ ntpServerIP IpAddress
+}
+
+ntpIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "This object identifies the entry."
+ ::= { ntpEntry 1 }
+
+ntpServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of an NTP Server. Set 0.0.0.0 or
+ 255.255.255.255 to remove this config."
+ ::= { ntpEntry 2 }
+
+
+-- -----------------------------------------------------------------------------
+--dhcpServer
+-- -----------------------------------------------------------------------------
+dhcpServerEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable or disable dhcp server function."
+ ::= { dhcpServer 1 }
+
+-- -----------------------------------------------------------------------------
+--dhcpServerPoolTable
+-- -----------------------------------------------------------------------------
+
+dhcpServerPoolTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpServerPoolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DHCP server of the switch."
+ ::= { dhcpServer 2 }
+
+dhcpServerPoolEntry OBJECT-TYPE
+ SYNTAX DhcpServerPoolEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing DHCP server information
+ of the switch. "
+ INDEX { dhcpServerPoolIndex }
+ ::= { dhcpServerPoolTable 1 }
+
+DhcpServerPoolEntry ::= SEQUENCE {
+ dhcpServerPoolIndex Integer32,
+ dhcpServerPoolName DisplayString,
+ dhcpServerPoolNetwork IpAddress,
+ dhcpServerPoolSubMask IpAddress,
+ dhcpServerPoolGateway IpAddress,
+ dhcpServerPoolLeaseTime Integer32,
+ dhcpServerPoolStatus RowStatus
+}
+
+dhcpServerPoolIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of the Address Pool."
+ ::= { dhcpServerPoolEntry 1 }
+
+dhcpServerPoolName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The address pool name."
+ ::= { dhcpServerPoolEntry 2 }
+
+dhcpServerPoolNetwork OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Subnet of the IP Address Pool."
+ ::= { dhcpServerPoolEntry 3 }
+
+dhcpServerPoolSubMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The subnet mask of the IP Address Pool."
+ ::= { dhcpServerPoolEntry 4 }
+
+dhcpServerPoolGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The gateway address of the IP Address Pool."
+ ::= { dhcpServerPoolEntry 5 }
+
+dhcpServerPoolLeaseTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The lease time(in second) of the Address Pool."
+ ::= { dhcpServerPoolEntry 6 }
+
+dhcpServerPoolStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of the Address Pool."
+ ::= { dhcpServerPoolEntry 7 }
+
+-- -----------------------------------------------------------------------------
+--dhcpExcludedTable
+-- -----------------------------------------------------------------------------
+
+dhcpExcludedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpExcludedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DHCP server of the switch."
+ ::= { dhcpServer 3 }
+
+dhcpExcludedEntry OBJECT-TYPE
+ SYNTAX DhcpExcludedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing DHCP server information
+ of the switch. "
+ INDEX { dhcpServerPoolIndex , dhcpExcludedIndex}
+ ::= { dhcpExcludedTable 1 }
+
+DhcpExcludedEntry ::= SEQUENCE {
+ dhcpExcludedIndex Integer32,
+ dhcpExcludedIp IpAddress,
+ dhcpExcludedStatus RowStatus
+}
+
+dhcpExcludedIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of the Excluded Table."
+ ::= { dhcpExcludedEntry 1 }
+
+dhcpExcludedIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address ."
+ ::= { dhcpExcludedEntry 2 }
+
+dhcpExcludedStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of a address pool."
+ ::= { dhcpExcludedEntry 3 }
+
+
+-- -----------------------------------------------------------------------------
+--dhcpManualBindingTable
+-- -----------------------------------------------------------------------------
+
+dhcpManualBindingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpManualBindingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DHCP server of the switch."
+ ::= { dhcpServer 4 }
+
+dhcpManualBindingEntry OBJECT-TYPE
+ SYNTAX DhcpManualBindingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing DHCP server information
+ of the switch. "
+ INDEX { dhcpServerPoolIndex,dhcpManualBindingIndex }
+ ::= { dhcpManualBindingTable 1 }
+
+DhcpManualBindingEntry ::= SEQUENCE {
+ dhcpManualBindingIndex Integer32,
+ dhcpManualBindingIp IpAddress,
+ dhcpManualBindingMac MacAddress,
+ dhcpManualBindingStatus RowStatus
+}
+
+dhcpManualBindingIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of the Static Binding Table."
+ ::= { dhcpManualBindingEntry 1 }
+
+dhcpManualBindingIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address."
+ ::= { dhcpManualBindingEntry 2 }
+
+dhcpManualBindingMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The MAC address."
+ ::= { dhcpManualBindingEntry 3 }
+
+dhcpManualBindingStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of the binding."
+ ::= { dhcpManualBindingEntry 4 }
+
+-- -----------------------------------------------------------------------------
+-- dhcpStaticPortTable
+-- -----------------------------------------------------------------------------
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5
+ dhcpStaticPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpStaticPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of descriptive information and configuration about
+ DHCP server of the switch."
+ ::= { dhcpServer 5 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5.1
+ dhcpStaticPortEntry OBJECT-TYPE
+ SYNTAX DhcpStaticPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing DHCP server information
+ of the switch. "
+ INDEX { dhcpServerPoolIndex, dhcpStaticPortIndex }
+ ::= { dhcpStaticPortTable 1 }
+
+
+ DhcpStaticPortEntry ::=
+ SEQUENCE {
+ dhcpStaticPortIndex
+ Integer32,
+ dhcpStaticPortNumber
+ INTEGER,
+ dhcpStaticPortIp
+ IpAddress,
+ dhcpStaticPortStatus
+ RowStatus
+ }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5.1.1
+ dhcpStaticPortIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the StaticPort Table."
+ ::= { dhcpStaticPortEntry 1 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5.1.2
+ dhcpStaticPortNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port number ."
+ ::= { dhcpStaticPortEntry 2 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5.1.3
+ dhcpStaticPortIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address ."
+ ::= { dhcpStaticPortEntry 3 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.5.1.4
+ dhcpStaticPortStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of a static port entry."
+ ::= { dhcpStaticPortEntry 4 }
+
+-- -----------------------------------------------------------------------------
+--dhcpOption82Table
+-- -----------------------------------------------------------------------------
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6
+ dhcpOption82Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpOption82Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DHCP server option82 table."
+ ::= { dhcpServer 6 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1
+ dhcpOption82Entry OBJECT-TYPE
+ SYNTAX DhcpOption82Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "DHCP server option82 entry."
+ INDEX { dhcpServerPoolIndex, dhcpOption82Index }
+ ::= { dhcpOption82Table 1 }
+
+
+ DhcpOption82Entry ::=
+ SEQUENCE {
+ dhcpOption82Index
+ Integer32,
+ dhcpOption82CircuitIdType
+ INTEGER,
+ dhcpOption82CircuitIdValue
+ OCTET STRING,
+ dhcpOption82RemoteIdType
+ INTEGER,
+ dhcpOption82RemoteIdValue
+ OCTET STRING,
+ dhcpOption82Ip
+ IpAddress,
+ dhcpOption82Status
+ RowStatus
+ }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.1
+ dhcpOption82Index OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the table."
+ ::= { dhcpOption82Entry 1 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.2
+ dhcpOption82CircuitIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ any(0),
+ string(2),
+ hexadecimal(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Circuit-ID type of this option."
+ ::= { dhcpOption82Entry 2 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.3
+ dhcpOption82CircuitIdValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Circuit-ID value of this option."
+ ::= { dhcpOption82Entry 3 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.4
+ dhcpOption82RemoteIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ any(0),
+ string(2),
+ hexadecimal(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Remote-ID type of this option."
+ ::= { dhcpOption82Entry 4 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.5
+ dhcpOption82RemoteIdValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Remote-ID value of this option."
+ ::= { dhcpOption82Entry 5 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.6
+ dhcpOption82Ip OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP Address bind to this option."
+ ::= { dhcpOption82Entry 6 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.6.1.7
+ dhcpOption82Status OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "he status of a static port entry."
+ ::= { dhcpOption82Entry 7 }
+
+-- -----------------------------------------------------------------------------
+--dhcpServerLeasedTable
+-- -----------------------------------------------------------------------------
+
+dhcpServerLeasedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpServerLeasedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DHCP server of the switch."
+ ::= { dhcpServer 7 }
+
+dhcpServerLeasedEntry OBJECT-TYPE
+ SYNTAX DhcpServerLeasedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing DHCP server information
+ of the switch. "
+ INDEX { dhcpServerPoolIndex, dhcpServerLeasedIndex }
+ ::= { dhcpServerLeasedTable 1 }
+
+DhcpServerLeasedEntry ::= SEQUENCE {
+ dhcpServerLeasedIndex Integer32,
+ dhcpServerLeasedIp IpAddress,
+ dhcpServerLeasedMac MacAddress,
+ dhcpServerLeasedType INTEGER,
+ dhcpServerLeasedTime Integer32
+}
+
+dhcpServerLeasedIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of the Leased Table."
+ ::= { dhcpServerLeasedEntry 1 }
+
+dhcpServerLeasedIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client IP address."
+ ::= { dhcpServerLeasedEntry 2 }
+
+dhcpServerLeasedMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client MAC address."
+ ::= { dhcpServerLeasedEntry 3 }
+
+dhcpServerLeasedType OBJECT-TYPE
+ SYNTAX INTEGER {
+ manual(1),
+ dynamic(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dhcpServerLeasedEntry 4 }
+
+dhcpServerLeasedTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The lease time of the client."
+ ::= { dhcpServerLeasedEntry 5 }
+
+
+-- -----------------------------------------------------------------------------
+--dhcpRelayAgent
+-- -----------------------------------------------------------------------------
+
+dhcpRelayAgentEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable or disable dhcp relay agent function."
+ ::= { dhcpServer 8 }
+
+-- -----------------------------------------------------------------------------
+--dhcpRelayAgentPolicy
+-- -----------------------------------------------------------------------------
+
+dhcpRelayAgentPolicy OBJECT-TYPE
+ SYNTAX INTEGER {
+ keep(1),
+ drop(2),
+ replace(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Keep(1): Keeps the original option 82 field and forwards to server
+ drop(2): Drops the option 82 field and do not add any option 82 field
+ replace(3): Replaces the existing option 82 field and adds new option
+ 82 field. (This is the default setting)"
+ ::= { dhcpServer 9 }
+
+-- -----------------------------------------------------------------------------
+--dhcpRelayAgentCircuitIdTable
+-- -----------------------------------------------------------------------------
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10
+ dhcpRelayAgentCircuitIdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpRelayAgentCircuitIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { dhcpServer 10 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10.1
+ dhcpRelayAgentCircuitIdEntry OBJECT-TYPE
+ SYNTAX DhcpRelayAgentCircuitIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { dhcpRelayAgentCircuitIdPortNum }
+ ::= { dhcpRelayAgentCircuitIdTable 1 }
+
+
+ DhcpRelayAgentCircuitIdEntry ::=
+ SEQUENCE {
+ dhcpRelayAgentCircuitIdPortNum
+ Integer32,
+ dhcpRelayAgentCircuitIdType
+ Integer32,
+ dhcpRelayAgentCircuitIdValue
+ OCTET STRING,
+ dhcpRelayAgentCircuitIdDisplay
+ OCTET STRING
+ }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10.1.1
+ dhcpRelayAgentCircuitIdPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { dhcpRelayAgentCircuitIdEntry 1 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10.1.2
+ dhcpRelayAgentCircuitIdType OBJECT-TYPE
+ SYNTAX Integer32 {
+ default(0),
+ string(2),
+ hexadecimal(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Circuit-ID type of the Option82 added by Relay Agent."
+ ::= { dhcpRelayAgentCircuitIdEntry 2 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10.1.3
+ dhcpRelayAgentCircuitIdValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Circuit-ID value of the Option82 added by Relay Agent, the format
+ can be String or Hexadecimal value."
+ ::= { dhcpRelayAgentCircuitIdEntry 3 }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.10.1.4
+ dhcpRelayAgentCircuitIdDisplay OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display the Circuit-ID value by Hexadecimal format"
+ ::= { dhcpRelayAgentCircuitIdEntry 4 }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.11
+ dhcpRelayAgentRemoteIdType OBJECT-TYPE
+ SYNTAX INTEGER {
+ default(0),
+ string(2),
+ hexadecimal(3),
+ ip(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote-ID type of the Option82 added by Relay Agent."
+ ::= { dhcpServer 11 }
+
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.12
+ dhcpRelayAgentRemoteIdValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote-ID value of the Option82 added by Relay Agent, the format
+ can be String or Hexadecimal value."
+ ::= { dhcpServer 12 }
+
+ -- 1.3.6.1.4.1.24062.2.4.1.2.5.13
+ dhcpRelayAgentRemoteIdDisplay OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote-ID value of the Option82 added by Relay Agent."
+ ::= { dhcpServer 13 }
+
+-- -----------------------------------------------------------------------------
+--dhcpHelperAddrTable
+-- -----------------------------------------------------------------------------
+
+dhcpHelperAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DhcpHelperAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DHCP relay helper address of the switch."
+ ::= { dhcpServer 14 }
+
+dhcpHelperAddressEntry OBJECT-TYPE
+ SYNTAX DhcpHelperAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing DHCP relay information
+ of the switch. "
+ INDEX { dhcpHelperAddress }
+ ::= { dhcpHelperAddressTable 1 }
+
+DhcpHelperAddressEntry ::= SEQUENCE {
+ dhcpHelperAddress IpAddress,
+
+}
+
+dhcpHelperAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address ."
+ ::= { dhcpHelperAddressEntry 1 }
+
+
+
+
+-- -----------------------------------------------------------------------------
+-- backupAndRestore
+-- -----------------------------------------------------------------------------
+
+backupServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of a TFTP server to which a
+ startup configuration can be uploaded."
+ DEFVAL { '00000000'H }
+ ::= { backupAndRestore 1 }
+
+backupAgentBoardFwFileName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The filename to backup to."
+ DEFVAL { "Quagga.conf" }
+ ::= { backupAndRestore 2 }
+
+backupStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Setting this object to active(1) trigger the TFTP
+ upload action.
+ Setting this object to notActive(2) has no effect.
+ The system always returns the value notActive(2)
+ when this object is read."
+ ::= { backupAndRestore 3 }
+
+restoreServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of a TFTP server from which the
+ startup configuration can be downloaded."
+ DEFVAL { '00000000'H }
+ ::= { backupAndRestore 4 }
+
+restoreAgentBoardFwFileName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The file name to restore from."
+ DEFVAL { "Quagga.conf" }
+ ::= { backupAndRestore 5 }
+
+restoreStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Setting this object to active(1) trigger the TFTP
+ download action.
+ Setting this object to notActive(2) has no effect.
+ The system always returns the value notActive(2)
+ when this object is read."
+ ::= { backupAndRestore 6 }
+
+-- -----------------------------------------------------------------------------
+-- tftpUpgrade
+-- -----------------------------------------------------------------------------
+
+tftpDownloadServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of a TFTP server where a firmware image can
+ be downloaded."
+ DEFVAL { '00000000'H }
+ ::= { tftpUpgrade 1 }
+
+tftpDownloadAgentBoardFwFileName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The file name of the firmware to be downloaded."
+ DEFVAL { "firmware.bin" }
+ ::= { tftpUpgrade 2 }
+
+tftpDownloadStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Setting this object to active(1) trigger the TFTP
+ download action.
+ Setting this object to notActive(2) has no effect.
+ The system always returns the value notActive(2)
+ when this object is read."
+ ::= { tftpUpgrade 3 }
+
+-- -----------------------------------------------------------------------------
+-- factoryDefault
+-- -----------------------------------------------------------------------------
+
+factoryDefaultActive OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set to active(1) to reload factory default configuration.
+ Reloading factory default will overwrite your current
+ configuration file with factocy default configuration while
+ current IP configuration is reserved.
+ Please reboot the device to make factory default configuration
+ take effect.
+ Set notActive(2) has no effect. The system always returns the
+ value notActive(2) when this object is read."
+ ::= { factoryDefault 1 }
+
+-- -----------------------------------------------------------------------------
+-- systemReboot
+-- -----------------------------------------------------------------------------
+
+systemRebootActive OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set active(1) to restart the device.
+ Set to notActive(2) has no effect. The device always returns
+ the value notActive(2) when this object is read."
+ DEFVAL { notActive }
+ ::= { systemReboot 1 }
+
+
+-- -----------------------------------------------------------------------------
+-- portConfiguration
+-- -----------------------------------------------------------------------------
+
+portControl OBJECT IDENTIFIER ::= { portConfiguration 1 }
+portStatus OBJECT IDENTIFIER ::= { portConfiguration 2 }
+rateLimiting OBJECT IDENTIFIER ::= { portConfiguration 3 }
+portTrunk OBJECT IDENTIFIER ::= { portConfiguration 4 }
+
+portCtrlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortCtrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of information and configuration for each ports."
+ ::= { portControl 1 }
+
+portCtrlEntry OBJECT-TYPE
+ SYNTAX PortCtrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information and configuration for a port."
+ INDEX { portCtrlIndex }
+ ::= { portCtrlTable 1 }
+
+PortCtrlEntry ::= SEQUENCE {
+ portCtrlIndex INTEGER,
+ portCtrlPortName DisplayString,
+ portCtrlPortStatus INTEGER,
+ portCtrlSpeedAndDuplex INTEGER,
+ portCtrlFlowControl INTEGER,
+ portCtrlPortDescription DisplayString
+}
+
+portCtrlIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of the port control entry."
+ ::= { portCtrlEntry 1 }
+
+portCtrlPortName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..7))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The name of port."
+ ::= { portCtrlEntry 2 }
+
+portCtrlPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "To enable or disable of this port."
+ ::= { portCtrlEntry 3 }
+
+portCtrlSpeedAndDuplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ autoNegotiation(1),
+ tenMbpsHalfDuplex(2),
+ tenMbpsFullDuplex(3),
+ hundredMbpsHalfDuplex(4),
+ hundredMbpsFullDuplex(5),
+ thousandMbpsFullDuplex(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Speed and duplex configuraion.
+
+ Different speed and duplex modes are available. There are speeds:
+ 1000 megabits per second (Gigabit Ethernet), 100 megabits per
+ second (Fast Ethernet), and 10 megabits per second (Legacy
+ Ethernet).
+
+ Full-duplex allows packets to be transmitted in both directions
+ at the same time, while half-duplex allows a device to either
+ transmit or receive, but not both at the same time. Full-duplex
+ may have double bandwidth than half-duplex.
+
+ You can configure manually from the possible options, listed from
+ best to worst:
+ 1Gb full-duplex(6)
+ 100Mb full-duplex(5)
+ 100Mb half-duplex(4)
+ 10Mb full-duplex(3)
+ 10Mb half-duplex(2)
+
+ Set to autoNegotiation(1) to allow the two interfaces on the link
+ to exchange the capabilities and characteristics of the each side,
+ and select the best operating mode automatically when a cable is
+ plugged in."
+ ::= { portCtrlEntry 4 }
+
+portCtrlFlowControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(1),
+ symmetric(2)
+-- asymmetric(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Flow control configuration.
+
+ Flow control is used to throttle the throughput rate of an
+ end station to avoid dropping packets during network
+ congestion. If flow control mode is not set and if there is
+ no packet buffer space available, the incoming packets are
+ discarded.
+
+ Symmetric Flow Control stops and restarts packet transmission
+ by transmitting and receiving pause frames. When a port's
+ free buffer space is almost empty, the device send out a Pause
+ frame to stop the remove node from sending more frames into
+ the switch. When congestion on the port is relieved, the device
+ send out a Pause frame with pause time equal to zero, making
+ the remove node resume transmission."
+ DEFVAL { disable }
+ ::= { portCtrlEntry 5 }
+
+portCtrlPortDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..138))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The description of port."
+ ::= { portCtrlEntry 6 }
+
+-- -----------------------------------------------------------------------------
+-- portStatusTable
+-- -----------------------------------------------------------------------------
+
+portStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive and statistics information about
+ each ports."
+ ::= { portStatus 1 }
+
+portStatusEntry OBJECT-TYPE
+ SYNTAX PortStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing statistics information of a port."
+ INDEX { portStatusIndex }
+ ::= { portStatusTable 1 }
+
+PortStatusEntry ::= SEQUENCE {
+ portStatusIndex Integer32,
+ portStatusType INTEGER,
+ portStatusLink INTEGER,
+ portStatusState INTEGER,
+ portStatusSpeedDuplex INTEGER,
+ portStatusFlowCtrl INTEGER,
+ sfpVender DisplayString,
+ sfpWavelength Integer32,
+ sfpDistance Integer32
+}
+
+portStatusIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Index of port statistic table."
+ ::= { portStatusEntry 1 }
+
+portStatusType OBJECT-TYPE
+ SYNTAX INTEGER {
+ hundredBaseTX(1),
+ thousandBaseT(2),
+ hundredBaseFX(3),
+ thousandBaseSX(4),
+ thousandBaseLX(5),
+ other(6),
+ notPresent(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicates the type of the port."
+ ::= { portStatusEntry 2 }
+
+portStatusLink OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicate the link state of the port."
+ ::= { portStatusEntry 3 }
+
+portStatusState OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicate the state of the port."
+ ::= { portStatusEntry 4 }
+
+portStatusSpeedDuplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ autoNegotiation(1),
+ tenMbpsHalfDuplex(2),
+ tenMbpsFullDuplex(3),
+ hundredMbpsHalfDuplex(4),
+ hundredMbpsFullDuplex(5),
+ thousandMbpsFullDuplex(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicate the speed and duplex mode of the port."
+ ::= { portStatusEntry 5 }
+
+portStatusFlowCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(1),
+ symmetric(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicate the flow control status of the port."
+ ::= { portStatusEntry 6 }
+
+sfpVender OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The vender name of the Small Form Pluggable (SFP) optical
+ transceiver module."
+ ::= { portStatusEntry 7 }
+
+sfpWavelength OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The wave length in nanometers (nm) of the Small Form
+ Pluggable (SFP) optical transceiver module."
+ ::= { portStatusEntry 8 }
+
+sfpDistance OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The maximum transimission distance in meters of the Small
+ Form Pluggable (SFP) optical transceiver module."
+ ::= { portStatusEntry 9 }
+
+-- -----------------------------------------------------------------------------
+-- portSfpTable
+-- -----------------------------------------------------------------------------
+portSfpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortSfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about SFP"
+ ::= { portStatus 2 }
+
+portSfpEntry OBJECT-TYPE
+ SYNTAX PortSfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing SFP information of a port."
+ INDEX { portSfpIndex }
+ ::= { portSfpTable 1 }
+
+PortSfpEntry ::= SEQUENCE {
+ portSfpIndex Integer32,
+ portSfpEject INTEGER,
+ portSfpScan INTEGER,
+ portSfpDdmStatus INTEGER,
+ portSfpDdmTempatureCurrent DisplayString,
+ portSfpDdmTempatureRange DisplayString,
+ portSfpDdmTxPowerCurrent DisplayString,
+ portSfpDdmTxPowerRange DisplayString,
+ portSfpDdmRxPowerCurrent DisplayString,
+ portSfpDdmRxPowerRange DisplayString
+}
+
+portSfpIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Index of port SFP table."
+ ::= { portSfpEntry 1 }
+
+portSfpEject OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Eject SFP"
+ ::= { portSfpEntry 2 }
+
+portSfpScan OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Scan SFP"
+ ::= { portSfpEntry 3 }
+
+portSfpDdmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)Enable SFP digital diagnostic and monitoring.
+ (2)Disable SFP digital diagnostic and monitoring."
+ ::= { portSfpEntry 4 }
+
+portSfpDdmTempatureCurrent OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..15))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The current SFP Tempature of port."
+ ::= { portSfpEntry 5 }
+
+portSfpDdmTempatureRange OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The range of SFP Tempature of port."
+ ::= { portSfpEntry 6 }
+
+portSfpDdmTxPowerCurrent OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..15))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The current SFP Transmitted Power of port."
+ ::= { portSfpEntry 7 }
+
+portSfpDdmTxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The range of SFP Transmitted Power of port."
+ ::= { portSfpEntry 8 }
+
+portSfpDdmRxPowerCurrent OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..15))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The current SFP Receiveed Power of port."
+ ::= { portSfpEntry 9 }
+
+portSfpDdmRxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The range of SFP Receiveed Power of port."
+ ::= { portSfpEntry 10 }
+
+-- -----------------------------------------------------------------------------
+-- rateLimiting
+-- -----------------------------------------------------------------------------
+
+rateLimitingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RateLimitingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ port rate limiting. You can set up bandwidth rate and packet
+ limitation type for each ports.
+
+ Rate limiting is used to control the rate of traffic sent or
+ received on a network interface. For ingress rate limiting,
+ traffic that is less than or equal to the specified rate is
+ received, whereas traffic that exceeds the rate is dropped.
+ For egress rate limiting, traffic that is less than or equal
+ to the specified rate is sent, whereas traffic that exceeds
+ the rate is dropped."
+ ::= { rateLimiting 1 }
+
+rateLimitingEntry OBJECT-TYPE
+ SYNTAX RateLimitingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information and configuration about
+ port rate limiting."
+ INDEX { rateLimitingPortNum }
+ ::= { rateLimitingTable 1 }
+
+RateLimitingEntry ::= SEQUENCE {
+ rateLimitingPortNum Integer32,
+ rateLimitingIngressLimitType INTEGER,
+ rateLimitingIngressRate Integer32,
+ rateLimitingEgressRate Integer32
+}
+
+rateLimitingPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The port number."
+ ::= { rateLimitingEntry 1 }
+
+rateLimitingIngressLimitType OBJECT-TYPE
+ SYNTAX INTEGER {
+ all(1),
+ broadcastMulticastFloodedUnicast(2),
+ broadcastMulticast(3),
+ broadcastOnly(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The type of ingress packets to be filtered."
+ ::= { rateLimitingEntry 2 }
+
+rateLimitingIngressRate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Ingress rate in Mbps, the rate range is from 1 Mbps to 100 Mbps
+ and zero means no limit."
+ ::= { rateLimitingEntry 3 }
+
+rateLimitingEgressRate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Egress rate in Mbps, the rate range is from 1 Mbps to 100 Mbps
+ and zero means no limit. Egress rate limiting has effect on
+ all types of packets, including unicast, multicast and
+ broadcast packets."
+ ::= { rateLimitingEntry 4 }
+
+-- -----------------------------------------------------------------------------
+-- portTrunk
+-- -----------------------------------------------------------------------------
+
+aggregatorSetting OBJECT IDENTIFIER ::= { portTrunk 1 }
+aggregatorStatus OBJECT IDENTIFIER ::= { portTrunk 2 }
+
+-- -----------------------------------------------------------------------------
+-- portTrunkAggregatorSettingTable
+-- -----------------------------------------------------------------------------
+
+portTrunkAggregatorSettingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortTrunkAggregatorSettingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ of each trunk group in this system.
+
+ Link aggregation, or IEEE 802.3ad, is a method of combining
+ physical network links into a single logical link for
+ increased bandwidth. With Link aggregation we are able to
+ increase the capacity and availability of the communications
+ channel between devices (both switches and end stations)
+ using existing Fast Ethernet and Gigabit Ethernet technology.
+ Two or more Gigabit Ethernet connections are combined in
+ order to increase the bandwidth capability and to create
+ resilient and redundant links. A set of multiple parallel
+ physical links between two devices is grouped together to
+ form a single logical link.
+
+ Link Aggregation also provides load balancing where the
+ processing and communications activity is distributed across
+ the links in a trunk so that no single link is overwhelmed."
+ ::= { aggregatorSetting 1 }
+
+portTrunkAggregatorSettingEntry OBJECT-TYPE
+ SYNTAX PortTrunkAggregatorSettingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling aggregator configuration."
+ INDEX { portTrunkPortIndex }
+ ::= { portTrunkAggregatorSettingTable 1 }
+
+
+PortTrunkAggregatorSettingEntry ::= SEQUENCE {
+ portTrunkPortIndex INTEGER,
+ portTrunkAggregatorGroupId INTEGER,
+ portTrunkAggregatorType INTEGER
+}
+
+portTrunkPortIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The port number."
+ ::= { portTrunkAggregatorSettingEntry 1 }
+
+portTrunkAggregatorGroupId OBJECT-TYPE
+ SYNTAX INTEGER {
+ trunkGroup1(1),
+ trunkGroup2(2),
+ trunkGroup3(3),
+ trunkGroup4(4),
+ trunkGroup5(5),
+ none(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Trunk group Id. Upto 8 ports can be aggregated into
+ a group and 5 groups can be configured in the device."
+ ::= { portTrunkAggregatorSettingEntry 2 }
+
+portTrunkAggregatorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ static(1),
+ lacp(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Aggregator type. You can assign the aggregator staticly
+ by setting to static(1), or setting to lacp(2) to enable the
+ LACP protocol.
+
+ The Link Aggregation Control Protocol (LACP) is required for
+ dynamically exchanging configuration information between the
+ peer devices in order to automatically configure and maintain
+ link aggregation groups. The protocol is able to automatically
+ detect the presence and capabilities of other aggregation
+ capable devices, i.e. with LACP it is possible to specify which
+ links in a system can be aggregated.
+
+ This column has no effect if Group Id is set to none."
+ ::= { portTrunkAggregatorSettingEntry 3 }
+
+
+portTrunkAggregatorSettingApply OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1), -- state, read-write
+ notactive(2) -- state, read-only
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "set active(1) to apply the configuration"
+ ::= { aggregatorSetting 2 }
+
+
+-- -----------------------------------------------------------------------------
+-- portTrunkAggregatorStatusTable
+-- -----------------------------------------------------------------------------
+
+portTrunkAggregatorStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortTrunkAggregatorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about trunk groups in
+ the device."
+ ::= { aggregatorStatus 1 }
+
+portTrunkAggregatorStatusEntry OBJECT-TYPE
+ SYNTAX PortTrunkAggregatorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information about current configuration
+ of trunk groups."
+ INDEX { portTrunkAggregatorGroupIndex }
+ ::= { portTrunkAggregatorStatusTable 1 }
+
+PortTrunkAggregatorStatusEntry ::= SEQUENCE {
+ portTrunkAggregatorGroupIndex INTEGER,
+ portTrunkAggregatorGroupType INTEGER,
+ portTrunkAggregatorGroupMember PortList,
+ portTrunkAggregatorIndividual PortList,
+ portTrunkAggregatorLinkDown PortList
+}
+
+portTrunkAggregatorGroupIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The trunk group identifier."
+ ::= { portTrunkAggregatorStatusEntry 1 }
+
+portTrunkAggregatorGroupType OBJECT-TYPE
+ SYNTAX INTEGER {
+ static(1),
+ lacp(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Aggregator type.
+ (1) The trunk group is LACP disabled and configured staticly
+ by administrator.
+ (2) The trunk group is LACP enabled. "
+ ::= { portTrunkAggregatorStatusEntry 2 }
+
+portTrunkAggregatorGroupMember OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The ports are aggregated with other ports."
+ ::= { portTrunkAggregatorStatusEntry 3 }
+
+portTrunkAggregatorIndividual OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "A port is LACP enabled but not aggregated with other ports."
+ ::= { portTrunkAggregatorStatusEntry 4 }
+
+portTrunkAggregatorLinkDown OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The ports which are linked down."
+ ::= { portTrunkAggregatorStatusEntry 5 }
+
+-- -----------------------------------------------------------------------------
+-- networkRedundancy
+-- -----------------------------------------------------------------------------
+
+-- superRing OBJECT IDENTIFIER ::= { networkRedundancy 1 }
+-- rstp OBJECT IDENTIFIER ::= { networkRedundancy 2 }
+-- bridgeInformation OBJECT IDENTIFIER ::= { networkRedundancy 3 }
+redundantRing OBJECT IDENTIFIER ::= { networkRedundancy 4 }
+stp OBJECT IDENTIFIER ::= { networkRedundancy 5 }
+stpBridgeInformation OBJECT IDENTIFIER ::= { networkRedundancy 6 }
+mstp OBJECT IDENTIFIER ::= { networkRedundancy 7 }
+mstpBridgeInformation OBJECT IDENTIFIER ::= { networkRedundancy 8 }
+
+
+-- -----------------------------------------------------------------------------
+-- superRing
+-- -----------------------------------------------------------------------------
+
+
+-- -----------------------------------------------------------------------------
+-- redundantRingConfigTable
+-- -----------------------------------------------------------------------------
+
+redundantRingConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RedundantRingConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of configuration about redundancy protocol in the device."
+ ::= { redundantRing 1 }
+
+redundantRingConfigEntry OBJECT-TYPE
+ SYNTAX RedundantRingConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information about current configuration
+ of rings."
+ INDEX { superRingConfigId }
+ ::= { redundantRingConfigTable 1 }
+
+RedundantRingConfigEntry ::= SEQUENCE {
+ superRingConfigId INTEGER,
+ superRingStatus RowStatus,
+ superRingName DisplayString,
+ superRingConfigVersion INTEGER,
+ superRingDevicePriority INTEGER,
+ superRingRingPort1 INTEGER,
+ superRingRingPort2 INTEGER,
+ superRingRingPort1PathCost INTEGER,
+ superRingRingPort2PathCost INTEGER,
+ superRingRapidDualHomingStatus INTEGER
+}
+
+superRingConfigId OBJECT-TYPE
+ SYNTAX INTEGER(0..15)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Ring Id."
+ ::= { redundantRingConfigEntry 1 }
+
+superRingName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Super Ring name."
+ ::= { redundantRingConfigEntry 2 }
+
+superRingConfigVersion OBJECT-TYPE
+ SYNTAX INTEGER {
+ superRing(1),
+ rapidSuperRing(2),
+ anyRing(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Super Ring funtion version selection.
+ Super Ring: Backward compatible with legacy super ring mechanism.
+ Note: This model supports v1 non-Redundancy Management mode only.
+ Rapid Super Ring: New mechanism. The recovery time is less than 30ms.
+ Any Ring:
+ "
+ --DEFVAL { rapidSuperRing }
+ ::= { redundantRingConfigEntry 3 }
+
+superRingDevicePriority OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Super Ring device priority setting."
+ --DEFVAL { 128 }
+ ::= { redundantRingConfigEntry 4 }
+
+superRingRingPort1 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "RingPort1 should not equal to RingRort2."
+ ::= { redundantRingConfigEntry 5 }
+
+superRingRingPort2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "RingPort2 should not equal to RingRort1."
+ ::= { redundantRingConfigEntry 6 }
+
+superRingRingPort1PathCost OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION ""
+ --DEFVAL { 128 }
+ ::= {redundantRingConfigEntry 7 }
+
+superRingRingPort2PathCost OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION ""
+ --DEFVAL { 128 }
+ ::= { redundantRingConfigEntry 8 }
+
+superRingRapidDualHomingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Rapid Dual Homing funtion status.
+ Rapid Dual Homing is a redundancy protocol,
+ which is compatible with RSTP.
+ (1) Rapid Dual Homing function is enabled.
+ (2) Rapid Dual Homing function is disabled."
+ --DEFVAL { disable }
+ ::= { redundantRingConfigEntry 9 }
+
+superRingStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Status of this ring."
+ ::= { redundantRingConfigEntry 10 }
+
+
+-- -----------------------------------------------------------------------------
+-- redundantRingStatusTable
+-- -----------------------------------------------------------------------------
+
+redundantRingStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RedundantRingStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of status information about redundancy protocol in
+ the device."
+ ::= { redundantRing 2 }
+
+redundantRingStatusEntry OBJECT-TYPE
+ SYNTAX RedundantRingStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information about current status
+ of rings."
+ INDEX { superRingStatusId }
+ ::= { redundantRingStatusTable 1 }
+
+RedundantRingStatusEntry ::= SEQUENCE {
+ superRingStatusId INTEGER,
+ superRingVersion INTEGER,
+ superRingDeviceRole INTEGER,
+ superRingRingPortList1 PortList,
+ superRingRingPortList2 PortList,
+ superRingRingStatus INTEGER,
+ superRingRmMac MacAddress,
+ superRingBlockedPort PortList,
+ superRingRoleTransitionCount Integer32,
+ superRingRingStateTransitionCount Integer32
+}
+
+superRingStatusId OBJECT-TYPE
+ SYNTAX INTEGER(0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Ring Id."
+ ::= { redundantRingStatusEntry 1 }
+
+superRingVersion OBJECT-TYPE
+ SYNTAX INTEGER {
+ superRing(1),
+ rapidSuperRing(2),
+ anyRing(3),
+ notSupported(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Super Ring funtion version selection.
+ Super Ring: Backward compatible with legacy super ring mechanism.
+ Note: This model supports v1 non-Redundancy Management mode only.
+ Rapid Super Ring: New mechanism. The recovery time is less than 30ms.
+ Any Ring:
+ Not Supported:"
+ ::= { redundantRingStatusEntry 2 }
+
+superRingDeviceRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ rm(2),
+ non-RM(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Super Ring role status.
+ (1) disabled.
+ (2) Redundancy manager.
+ (3) Non redundancy manager."
+ ::= { redundantRingStatusEntry 3 }
+
+superRingRingPortList1 OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port list for ring port1."
+ ::= { redundantRingStatusEntry 4 }
+
+superRingRingPortList2 OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port list for ring port2."
+ ::= { redundantRingStatusEntry 5 }
+
+superRingRingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ normal(2),
+ abnormal(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Super Ring ring status.
+ (1) Disabled - The ring on this device is disabled.
+ (1) Normal - Ring is complete.
+ (2) Abnormal - Ring is not complete."
+ ::= { redundantRingStatusEntry 6 }
+
+superRingRmMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "RM mac address."
+ ::= { redundantRingStatusEntry 7 }
+
+superRingBlockedPort OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The blocked ports in ring Normal state."
+ ::= { redundantRingStatusEntry 8 }
+
+superRingRoleTransitionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { redundantRingStatusEntry 9 }
+
+superRingRingStateTransitionCount OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { redundantRingStatusEntry 10 }
+
+
+-- -----------------------------------------------------------------------------
+-- rstp
+-- -----------------------------------------------------------------------------
+
+
+-- -----------------------------------------------------------------------------
+-- bridgeInformation
+-- rstpRootBridgeInformationTable
+-- -----------------------------------------------------------------------------
+
+
+-- -----------------------------------------------------------------------------
+-- stp
+-- -----------------------------------------------------------------------------
+
+stpModeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ stp(1),
+ rstp(2),
+ mstp(3),
+ disabled(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable Spanning Tree protocol, Rapid Spanning Tree protocol,
+ or disable .
+
+ Rapid Spanning Tree Algorithm and Protocol (RSTP) provides a
+ loop free topology for any LAN or bridged network. RSTP is an
+ evolution of the Spanning Tree Protocol (STP), and was
+ introduced in the extension IEEE 802.1w, and provides for
+ faster spanning tree convergence after a topology change."
+ ::= { stp 1 }
+
+stpBridgeAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Bridge Address."
+ ::= { stp 2 }
+
+stpBridgePriority OBJECT-TYPE
+ SYNTAX Integer32 {
+ priority0(0),
+ priority4096(4096),
+ priority8192(8192),
+ priority12288(12288),
+ priority16384(16384),
+ priority20480(20480),
+ priority24576(24576),
+ priority28672(28672),
+ priority32768(32768),
+ priority36864(36864),
+ priority40960(40960),
+ priority45056(45056),
+ priority49152(49152),
+ priority53248(53248),
+ priority57344(57344),
+ priority61440(61440)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "A value used to identify the root bridge. The bridge with
+ the lowest value has the highest priority and is selected
+ as the root. Enter a number 0 through 61440 in steps of
+ 4096. If you change the value, you must restart RSTP.
+ This item can't be modified, if stpStatus was disabled."
+ ::= { stp 3 }
+
+stpMaxAge OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The number of seconds a bridge waits without receiving
+ Spanning-Tree Protocol configuration messages before
+ attempting a reconfiguration. Enter a number 6 through 40.
+ Note: 2*(Forward Delay Time-1) should be greater than or
+ equal to the Max Age. The Max Age should be greater than
+ or equal to 2*(Hello Time + 1).
+ This item can't be modified, if stpStatus was disabled."
+ ::= { stp 4 }
+
+stpHelloTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The number of seconds between the transmission of
+ Spanning-Tree Protocol configuration messages.
+ Enter a number 1 through 10
+ Note: 2*(Forward Delay Time-1) should be greater than or
+ equal to the Max Age. The Max Age should be greater
+ than or equal to 2*(Hello Time + 1).
+ This item can't be modified, if stpStatus was disabled."
+ ::= { stp 5 }
+
+stpForwardDelayTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The number of seconds a port waits before changing
+ from its Spanning-Tree Protocol learning and listening
+ states to the forwarding state. Enter a number 4 through 30.
+ Note:2*(Forward Delay Time-1) should be greater than or
+ equal to the Max Age. The Max Age should be greater than
+ or equal to 2*(Hello Time + 1).
+ This item can't be modified, if stpStatus was disabled."
+ ::= { stp 6 }
+
+-- -----------------------------------------------------------------------------
+-- stpPerPortCfgTable
+-- -----------------------------------------------------------------------------
+
+stpPerPortCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StpPerPortCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ STP on each port."
+ ::= { stp 7 }
+
+stpPerPortCfgEntry OBJECT-TYPE
+ SYNTAX StpPerPortCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring STP on a port."
+ INDEX { stpPerPortCfgPortNum }
+ ::= { stpPerPortCfgTable 1 }
+
+StpPerPortCfgEntry ::= SEQUENCE {
+ stpPerPortCfgPortNum Integer32,
+ stpPerPortCfgStpState INTEGER,
+ stpPerPortCfgPathCost Integer32,
+ stpPerPortCfgPriority Integer32,
+ stpPerPortCfgLinkType INTEGER,
+ stpPerPortCfgEdgePort INTEGER
+}
+
+stpPerPortCfgPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The port number."
+ ::= { stpPerPortCfgEntry 1 }
+
+stpPerPortCfgStpState OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable/Disable STP/RSTP/MSTP at this port. Disable STP state
+ when connecting a device in order to avoid STP waiting periods."
+ ::= { stpPerPortCfgEntry 2 }
+
+stpPerPortCfgPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The cost of the path to the other bridge from this
+ transmitting bridge at the specified port. Enter a number from
+ 1 through 200000000.
+ (0 will auto set path cost to standard recommended value)"
+ ::= { stpPerPortCfgEntry 3 }
+
+stpPerPortCfgPriority OBJECT-TYPE
+ SYNTAX Integer32 {
+ priority0(0),
+ priority16(16),
+ priority32(32),
+ priority48(48),
+ priority64(64),
+ priority80(80),
+ priority96(96),
+ priority112(112),
+ priority128(128),
+ priority144(144),
+ priority160(160),
+ priority176(176),
+ priority192(192),
+ priority208(208),
+ priority224(224),
+ priority240(240)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Decide which port should be blocked by priority in LAN. Enter
+ a number from 0 through 240 in steps of 16."
+ ::= { stpPerPortCfgEntry 4 }
+
+stpPerPortCfgLinkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ point2Point(2),
+ shared(3),
+ notSupport(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Some of the rapid state transactions that are
+ possible within RSTP are dependent upon whether
+ the Port concerned can only be connected to
+ exactly one other Bridge(ie., it is served by a
+ point-to-point LAN segment), or can be connected
+ to two or more Bridges(i.e., it is served by a
+ shared medium LAN segment).
+ The adminPointToPointMAC allow the p2p status
+ of the link to be manipulated adminitratively."
+ ::= { stpPerPortCfgEntry 5 }
+
+stpPerPortCfgEdgePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Present in implementations that support the
+ identification of edge ports. All ports
+ directly connected to end stations cannot
+ create bridging loops in the network and can
+ thus directly transition to forwarding,
+ skipping the listening and learning stages."
+ ::= { stpPerPortCfgEntry 6 }
+
+
+-- -----------------------------------------------------------------------------
+-- stpBridgeInformation
+-- stpRootInformationTable
+-- -----------------------------------------------------------------------------
+
+stpRootInformationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StpRootInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about root bridge
+ of rapid spanning tree in this system."
+ ::= { stpBridgeInformation 1 }
+
+stpRootInformationEntry OBJECT-TYPE
+ SYNTAX StpRootInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing information
+ about root bridge information of the STP."
+ INDEX { stpRootInformationIndex }
+ ::= { stpRootInformationTable 1 }
+
+StpRootInformationEntry ::= SEQUENCE {
+ stpRootInformationIndex Integer32,
+ stpRootInformationRootAddress DisplayString,
+ stpRootInformationRootPriority Integer32,
+ stpRootInformationRootPort DisplayString,
+ stpRootInformationRootPathCost Integer32,
+ stpRootInformationMaxAge Integer32,
+ stpRootInformationHelloTime Integer32,
+ stpRootInformationForwardDelay Integer32
+}
+
+stpRootInformationIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of root bridge information table."
+ ::= { stpRootInformationEntry 1 }
+
+stpRootInformationRootAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Address."
+ ::= { stpRootInformationEntry 2 }
+
+stpRootInformationRootPriority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Priority."
+ ::= { stpRootInformationEntry 3 }
+
+stpRootInformationRootPort OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Port."
+ ::= { stpRootInformationEntry 4 }
+
+stpRootInformationRootPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Path Cost."
+ ::= { stpRootInformationEntry 5 }
+
+stpRootInformationMaxAge OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Max Age."
+ ::= { stpRootInformationEntry 6 }
+
+stpRootInformationHelloTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Hello Time."
+ ::= { stpRootInformationEntry 7 }
+
+stpRootInformationForwardDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Forward Delay Time."
+ ::= { stpRootInformationEntry 8 }
+
+
+-- -----------------------------------------------------------------------------
+-- stpPerPortInfoTable
+-- -----------------------------------------------------------------------------
+
+stpPerPortInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StpPerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ rapid spanning tree (Per port)."
+ ::= { stpBridgeInformation 2 }
+
+stpPerPortInfoEntry OBJECT-TYPE
+ SYNTAX StpPerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion
+ about STP (Per port)."
+ INDEX { stpPerPortInfoPortNum }
+ ::= { stpPerPortInfoTable 1 }
+
+StpPerPortInfoEntry ::= SEQUENCE {
+ stpPerPortInfoPortNum Integer32,
+ stpPerPortInfoRole INTEGER,
+ stpPerPortInfoState INTEGER,
+ stpPerPortInfoPathCost Integer32,
+ stpPerPortInfoPriority Integer32,
+ stpPerPortInfoLinkType INTEGER,
+ stpPerPortInfoEdgePort INTEGER
+}
+
+stpPerPortInfoPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Port number."
+ ::= { stpPerPortInfoEntry 1 }
+
+stpPerPortInfoRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ root(1),
+ alternated(2),
+ designated(3),
+ backup(4),
+ disabled(5),
+ nonStp(6),
+ unknown(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Descriptive information about RSTP switch port roles:
+ root(1) A forwarding port that has been elected for
+ the spanning-tree topology.
+ alternate(2) An alternate path to the root bridge. This
+ path is different than using the root port.
+ designated(3) A forwarding port for every LAN segment.
+ backup(4) A backup/redundant path to a segment where
+ another switch port already connects.
+ disabled(5) RSTP is disabled on this port."
+
+ ::= { stpPerPortInfoEntry 2 }
+
+stpPerPortInfoState OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ learning(2),
+ forwarding(3),
+ blocking(4),
+ unknown(5),
+ nonStp(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION " "
+ ::= { stpPerPortInfoEntry 3 }
+
+
+
+stpPerPortInfoPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The cost of the path to the other bridge from
+ this transmitting bridge at the specified port.
+ Enter a number 1 through 200000000."
+ ::= { stpPerPortInfoEntry 4 }
+
+stpPerPortInfoPriority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Decide which port should be blocked by priority
+ in LAN. Enter a number 0 through 240 in steps of
+ 16."
+ ::= { stpPerPortInfoEntry 5 }
+
+stpPerPortInfoLinkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ point2Point(2),
+ shared(3),
+ notSupport(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Some of the rapid state transactions that are
+ possible within RSTP are dependent upon whether
+ the Port concerned can only be connected to
+ exactly one other Bridge(ie., it is served by a
+ point-to-point LAN segment), or can be connected
+ to two or more Bridges(i.e., it is served by a
+ shared medium LAN segment).
+
+ The adminPointToPointMAC allow the p2p status
+ of the link to be manipulated adminitratively.
+
+ STP does not support this function."
+ ::= { stpPerPortInfoEntry 6 }
+
+stpPerPortInfoEdgePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Present in implementations that support the
+ identification of edge ports. All ports
+ directly connected to end stations cannot
+ create bridging loops in the network and can
+ thus directly transition to forwarding,
+ skipping the listening and learning stages."
+ ::= { stpPerPortInfoEntry 7 }
+
+
+---------------------------------------------------------------------------
+-- mstp
+---------------------------------------------------------------------------
+mstpRegionName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "MSTP region name."
+ ::= { mstp 1 }
+
+mstpRegionRevision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "MSTP region revision."
+ ::= { mstp 2 }
+
+-- -----------------------------------------------------------------------------
+-- mstpPerInstCfgTable
+-- -----------------------------------------------------------------------------
+
+mstpPerInstCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MstpPerInstCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ STP on each port."
+ ::= { mstp 3 }
+
+mstpPerInstCfgEntry OBJECT-TYPE
+ SYNTAX MstpPerInstCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring MSTP on a instance."
+ INDEX { mstpPerInstCfgInstanceID }
+ ::= { mstpPerInstCfgTable 1 }
+
+MstpPerInstCfgEntry ::= SEQUENCE {
+ mstpPerInstCfgInstanceID Integer32,
+ mstpPerInstCfgVlanGroup DisplayString,
+ mstpPerInstCfgInstancePriority Integer32,
+ mstpPerInstCfgStatus RowStatus
+}
+
+mstpPerInstCfgInstanceID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The instance ID."
+ ::= { mstpPerInstCfgEntry 1 }
+
+mstpPerInstCfgVlanGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "VLAN group of instance."
+ ::= { mstpPerInstCfgEntry 2 }
+
+mstpPerInstCfgInstancePriority OBJECT-TYPE
+ SYNTAX Integer32 {
+ priority0(0),
+ priority4096(4096),
+ priority8192(8192),
+ priority12288(12288),
+ priority16384(16384),
+ priority20480(20480),
+ priority24576(24576),
+ priority28672(28672),
+ priority32768(32768),
+ priority36864(36864),
+ priority40960(40960),
+ priority45056(45056),
+ priority49152(49152),
+ priority53248(53248),
+ priority57344(57344),
+ priority61440(61440)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "A value used to identify the instance root. The instance with
+ the lowest value has the highest priority and is selected
+ as the root. Enter a number 0 through 61440 in steps of
+ 4096."
+ ::= { mstpPerInstCfgEntry 3 }
+
+mstpPerInstCfgStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Status of this Instance."
+ ::= { mstpPerInstCfgEntry 4 }
+
+-- -----------------------------------------------------------------------------
+-- mstpPerPortCfgTable
+-- -----------------------------------------------------------------------------
+
+mstpPerPortCfgTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MstpPerPortCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ MSTP on each port."
+ ::= { mstp 4 }
+
+mstpPerPortCfgEntry OBJECT-TYPE
+ SYNTAX MstpPerPortCfgEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring MSTP on a port."
+ INDEX { mstpPerPortCfgIndex }
+ ::= { mstpPerPortCfgTable 1 }
+
+MstpPerPortCfgEntry ::= SEQUENCE {
+ mstpPerPortCfgIndex Integer32,
+ mstpPerPortCfgInstanceID Integer32,
+ mstpPerPortCfgPortNum Integer32,
+ mstpPerPortCfgPathCost Integer32,
+ mstpPerPortCfgPriority Integer32,
+ mstpPerPortCfgLinkType INTEGER,
+ mstpPerPortCfgEdgePort INTEGER
+}
+
+mstpPerPortCfgIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of MstpPerPortCfgEntry."
+ ::= { mstpPerPortCfgEntry 1 }
+
+mstpPerPortCfgInstanceID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The instance ID."
+ ::= { mstpPerPortCfgEntry 2 }
+
+mstpPerPortCfgPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The port number."
+ ::= { mstpPerPortCfgEntry 3 }
+
+mstpPerPortCfgPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The cost of the path to the other bridge from this
+ transmitting bridge at the specified port. Enter a number from
+ 1 through 200000000.
+ (0 will auto set path cost to standard recommended value)"
+ ::= { mstpPerPortCfgEntry 4 }
+
+mstpPerPortCfgPriority OBJECT-TYPE
+ SYNTAX Integer32 {
+ priority0(0),
+ priority16(16),
+ priority32(32),
+ priority48(48),
+ priority64(64),
+ priority80(80),
+ priority96(96),
+ priority112(112),
+ priority128(128),
+ priority144(144),
+ priority160(160),
+ priority176(176),
+ priority192(192),
+ priority208(208),
+ priority224(224),
+ priority240(240)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Decide which port should be blocked by priority in LAN. Enter
+ a number from 0 through 240 in steps of 16."
+ ::= { mstpPerPortCfgEntry 5 }
+
+mstpPerPortCfgLinkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ point2Point(2),
+ shared(3),
+ notSupport(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Some of the rapid state transactions that are
+ possible within RSTP are dependent upon whether
+ the Port concerned can only be connected to
+ exactly one other Bridge(ie., it is served by a
+ point-to-point LAN segment), or can be connected
+ to two or more Bridges(i.e., it is served by a
+ shared medium LAN segment).
+ The adminPointToPointMAC allow the p2p status
+ of the link to be manipulated adminitratively."
+ ::= { mstpPerPortCfgEntry 6 }
+
+mstpPerPortCfgEdgePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Present in implementations that support the
+ identification of edge ports. All ports
+ directly connected to end stations cannot
+ create bridging loops in the network and can
+ thus directly transition to forwarding,
+ skipping the listening and learning stages."
+ ::= { mstpPerPortCfgEntry 7 }
+
+
+-- -----------------------------------------------------------------------------
+-- mstpBridgeInformation
+-- mstpRootInformationTable
+-- -----------------------------------------------------------------------------
+
+mstpRootInformationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MstpRootInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about root bridge
+ of rapid spanning tree in this system."
+ ::= { mstpBridgeInformation 1 }
+
+mstpRootInformationEntry OBJECT-TYPE
+ SYNTAX MstpRootInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing information
+ about root bridge information of the MSTP."
+ INDEX { mstpRootInformationInstanceID }
+ ::= { mstpRootInformationTable 1 }
+
+MstpRootInformationEntry ::= SEQUENCE {
+-- mstpRootInformationIndex Integer32,
+ mstpRootInformationInstanceID Integer32,
+ mstpRootInformationRootAddress DisplayString,
+ mstpRootInformationRootPriority Integer32,
+ mstpRootInformationRootPort DisplayString,
+ mstpRootInformationRootPathCost Integer32,
+ mstpRootInformationMaxAge Integer32,
+ mstpRootInformationHelloTime Integer32,
+ mstpRootInformationForwardDelay Integer32
+}
+
+--mstpRootInformationIndex OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Index of root bridge information table."
+-- ::= { mstpRootInformationEntry 1 }
+
+mstpRootInformationInstanceID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The instance ID."
+ ::= { mstpRootInformationEntry 1 }
+
+mstpRootInformationRootAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Address."
+ ::= { mstpRootInformationEntry 2 }
+
+mstpRootInformationRootPriority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Priority."
+ ::= { mstpRootInformationEntry 3 }
+
+mstpRootInformationRootPort OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Port."
+ ::= { mstpRootInformationEntry 4 }
+
+mstpRootInformationRootPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Root Path Cost."
+ ::= { mstpRootInformationEntry 5 }
+
+mstpRootInformationMaxAge OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Max Age."
+ ::= { mstpRootInformationEntry 6 }
+
+mstpRootInformationHelloTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Hello Time."
+ ::= { mstpRootInformationEntry 7 }
+
+mstpRootInformationForwardDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Forward Delay Time."
+ ::= { mstpRootInformationEntry 8 }
+
+
+-- -----------------------------------------------------------------------------
+-- mstpPerPortInfoTable
+-- -----------------------------------------------------------------------------
+
+mstpPerPortInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MstpPerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ rapid spanning tree (Per port)."
+ ::= { mstpBridgeInformation 2 }
+
+mstpPerPortInfoEntry OBJECT-TYPE
+ SYNTAX MstpPerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing information
+ about MSTP (Per port)."
+ INDEX { mstpPerPortInfoIndex }
+ ::= { mstpPerPortInfoTable 1 }
+
+MstpPerPortInfoEntry ::= SEQUENCE {
+ mstpPerPortInfoIndex Integer32,
+ mstpPerPortInfoInstanceID Integer32,
+ mstpPerPortInfoPortNum Integer32,
+ mstpPerPortInfoRole INTEGER,
+ mstpPerPortInfoState INTEGER,
+ mstpPerPortInfoPathCost Integer32,
+ mstpPerPortInfoPriority Integer32,
+ mstpPerPortInfoLinkType INTEGER,
+ mstpPerPortInfoEdgePort INTEGER
+}
+
+mstpPerPortInfoIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The index of MstpPerPortInfoEntry."
+ ::= { mstpPerPortInfoEntry 1 }
+
+mstpPerPortInfoInstanceID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The instance ID."
+ ::= { mstpPerPortInfoEntry 2 }
+
+mstpPerPortInfoPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port number."
+ ::= { mstpPerPortInfoEntry 3 }
+
+mstpPerPortInfoRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ root(1),
+ alternate(2),
+ designated(3),
+ backup(4),
+ master(5),
+ disabled(6),
+ boundary(7),
+ unknown(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Descriptive information about MSTP switch port roles:
+ disabled(1) MSTP is disabled on this port.
+ root(2) A forwarding port that has been elected for
+ the spanning-tree topology.
+ designated(3) A forwarding port for every LAN segment.
+ alternate(4) An alternate path to the root bridge. This
+ path is different than using the root port.
+ backup(5) A backup/redundant path to a segment where
+ another switch port already connects."
+ ::= { mstpPerPortInfoEntry 4 }
+
+mstpPerPortInfoState OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ listening(2),
+ learning(3),
+ forwarding(4),
+ blocking(5),
+ unknown(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION " "
+ ::= { mstpPerPortInfoEntry 5 }
+
+mstpPerPortInfoPathCost OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The cost of the path to the other bridge from
+ this transmitting bridge at the specified port.
+ Enter a number 1 through 200000000."
+ ::= { mstpPerPortInfoEntry 6 }
+
+mstpPerPortInfoPriority OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Decide which port should be blocked by priority
+ in LAN. Enter a number 0 through 240 in steps of
+ 16."
+ ::= { mstpPerPortInfoEntry 7 }
+
+mstpPerPortInfoLinkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ p2p-bound-stp(1),
+ p2p-bound-rstp(2),
+ p2p-bound-mstp(3),
+ p2p-internal-mstp(4),
+ shared-bound-stp(5),
+ shared-bound-rstp(6),
+ shared-bound-mstp(7),
+ shared-internal-mstp(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Some of the rapid state transactions that are
+ possible within MSTP are dependent upon whether
+ the Port concerned can only be connected to
+ exactly one other Bridge(ie., it is served by a
+ point-to-point LAN segment), or can be connected
+ to two or more Bridges(i.e., it is served by a
+ shared medium LAN segment).
+
+ The adminPointToPointMAC allow the p2p status
+ of the link to be manipulated adminitratively."
+ ::= { mstpPerPortInfoEntry 8 }
+
+mstpPerPortInfoEdgePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Present in implementations that support the
+ identification of edge ports. All ports
+ directly connected to end stations cannot
+ create bridging loops in the network and can
+ thus directly transition to forwarding,
+ skipping the listening and learning stages."
+ ::= { mstpPerPortInfoEntry 9 }
+
+
+---------------------------------------------------------------------------
+-- vlan
+---------------------------------------------------------------------------
+vlanManagementVlan OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The VLAN from which managemnet traffic can access the device.
+ By default, VLAN 1 is management VLAN."
+ DEFVAL { 1 }
+ ::= { vlan 1 }
+
+-- vlanStatus OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- disabled(1),
+-- ieee8021qVlan(2),
+-- portBasedVlan(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION ""
+-- ::= { vlan 2 }
+
+ieee8021qVlan OBJECT IDENTIFIER ::= { vlan 2 }
+-- portBasedVlan OBJECT IDENTIFIER ::= { vlan 4 }
+
+-- -----------------------------------------------------------------------------
+-- Vlan Port Configuration
+-- -----------------------------------------------------------------------------
+dot1qPortVlanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1qPortVlanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per port control and status information
+ for IEEE802.1Q VLAN configuration in the device."
+ ::= { ieee8021qVlan 1 }
+
+dot1qPortVlanEntry OBJECT-TYPE
+ SYNTAX Dot1qPortVlanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling IEEE802.1Q VLAN configuration for
+ a port on the device."
+ INDEX { dot1qPortIndex }
+ ::= { dot1qPortVlanTable 1 }
+
+Dot1qPortVlanEntry ::= SEQUENCE {
+ dot1qPortIndex INTEGER,
+ dot1qPvid INTEGER,
+ dot1qPortAcceptableFrameTypes INTEGER,
+ dot1qPortIngressFiltering INTEGER
+}
+
+dot1qPortIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The port identifier."
+ ::= { dot1qPortVlanEntry 1 }
+
+dot1qPvid OBJECT-TYPE
+ SYNTAX INTEGER(1..4094)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default Port VID, the VLAN ID assigned to an untagged
+ frame or a Priority-Tagged frame received on the port."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.1.1"
+ DEFVAL { 1 }
+ ::= { dot1qPortVlanEntry 2 }
+
+dot1qPortAcceptableFrameTypes OBJECT-TYPE
+ SYNTAX INTEGER {
+ admitAll(1),
+ admitOnlyVlanTagged(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "When admitOnlyVlanTagged(2) the device will discard untagged
+ frames or Priority-Tagged only frames received on this port.
+ When admitAll(1), untagged frames or Priority-Tagged only
+ frames received on this port will be accepted and assigned
+ the PVID for this frame. This control does not affect
+ VLAN independent BPDU frames, such as SuperRing, STP, GVRP
+ and LACP. It does affect VLAN dependent BPDU frames, such
+ as GMRP."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.1.3"
+ DEFVAL { admitAll }
+ ::= { dot1qPortVlanEntry 3 }
+
+dot1qPortIngressFiltering OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "When true(1) the device will discard incoming frames whose
+ VLAN classification do not include this port in its Member set.
+ When false(2), the port will accept all incoming frames
+ regardless its VLAN classification.
+ This control does not affect VLAN independent BPDU frames,
+ such as SuperRing, STP, GVRP and LACP. It does affect VLAN
+ dependent BPDU frames, such as GMRP."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.1.4"
+ DEFVAL { false }
+ ::= { dot1qPortVlanEntry 4 }
+
+
+-- -----------------------------------------------------------------------------
+-- Static VLAN Database
+-- -----------------------------------------------------------------------------
+
+dot1qVlanStaticTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1qVlanStaticEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing configuration information for each VLAN
+ configured into the device by management. All entries are
+ permanent and will be restored after the device is reset.
+ Upto 64 VLANs can be configured in this device.
+
+ IEEE 802.1Q Virtual LANs (VLANs) allow a single physical LAN
+ to be partitioned into several smaller logical LANs. VLANs
+ limit the broadcast domain, improve security and performance
+ and are ideal for separating systems or departments from each
+ other."
+-- The maximun number of VLAN supported by this device is 64."
+ ::= { ieee8021qVlan 2 }
+
+dot1qVlanStaticEntry OBJECT-TYPE
+ SYNTAX Dot1qVlanStaticEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Static information of a VLAN configured into the device by
+ management."
+ INDEX { dot1qVlanIndex }
+ ::= { dot1qVlanStaticTable 1 }
+
+Dot1qVlanStaticEntry ::= SEQUENCE {
+ dot1qVlanIndex INTEGER,
+ dot1qVlanStaticName DisplayString,
+ dot1qVlanStaticEgressPorts PortList,
+ dot1qVlanStaticUntaggedPorts PortList,
+ dot1qVlanStaticTaggedPorts PortList,
+ dot1qVlanStaticRowStatus RowStatus
+}
+
+dot1qVlanIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..4094)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The VLAN Identifier (VID) refering to this VLAN. The valid
+ range is from 1 to 4094."
+ ::= { dot1qVlanStaticEntry 1 }
+
+dot1qVlanStaticName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..12))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "An administratively assigned string, which is used to identify
+ the VLAN."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.2.1"
+ ::= { dot1qVlanStaticEntry 2 }
+
+dot1qVlanStaticEgressPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The set of ports which are permanently configured to
+ transmitting traffic for this VLAN as either tagged or
+ untagged frames.
+
+ Each octet within this value specifies a set of eight
+ ports, with the first octet specifying ports 1 through
+ 8, the second octet specifying ports 9 through 16, etc.
+ Within each octet, the most significant bit represents
+ the lowest numbered port, and the least significant bit
+ represents the highest numbered port. Thus, each port
+ of the bridge is represented by a single bit within the
+ value of this object. If that bit has a value of '1'
+ then that port is included in the set of ports; the port
+ is not included if its bit has a value of '0'.
+
+ Changes to this object affect the per-port per-VLAN
+ Registrar control for Registration Fixed for the
+ relevant GVRP state machine on each port.
+
+ A port may not be added in this set if it is already a
+ member of the set of ports in dot1qVlanForbiddenEgressPorts.
+
+ The default value of this object is a string of zeros,
+ indicating not fixed."
+ ::= { dot1qVlanStaticEntry 3 }
+
+dot1qVlanStaticUntaggedPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The set of ports which are permanently configured to
+ transmitting traffic for this VLAN as untagged frames.
+
+ Each octet within this value specifies a set of eight
+ ports, with the first octet specifying ports 1 through
+ 8, the second octet specifying ports 9 through 16, etc.
+ Within each octet, the most significant bit represents
+ the lowest numbered port, and the least significant bit
+ represents the highest numbered port. Thus, each port
+ of the bridge is represented by a single bit within the
+ value of this object. If that bit has a value of '1'
+ then that port is included in the set of ports; the port
+ is not included if its bit has a value of '0'.
+
+ Changes to this object affect the per-port per-VLAN
+ Registrar control for Registration Fixed for the
+ relevant GVRP state machine on each port.
+
+ The default value of this object for the default VLAN is a
+ portlist including all ports. There is no specified default
+ for other VLANs."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.2.1"
+ ::= { dot1qVlanStaticEntry 4 }
+
+dot1qVlanStaticTaggedPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The set of ports which are permanently configured to
+ transmitting traffic for this VLAN as tagged frames.
+
+ Each octet within this value specifies a set of eight
+ ports, with the first octet specifying ports 1 through
+ 8, the second octet specifying ports 9 through 16, etc.
+ Within each octet, the most significant bit represents
+ the lowest numbered port, and the least significant bit
+ represents the highest numbered port. Thus, each port
+ of the bridge is represented by a single bit within the
+ value of this object. If that bit has a value of '1'
+ then that port is included in the set of ports; the port
+ is not included if its bit has a value of '0'.
+
+ Changes to this object affect the per-port per-VLAN
+ Registrar control for Registration Fixed for the
+ relevant GVRP state machine on each port.
+
+ The default value of this object for the default VLAN is a
+ portlist including all ports. There is no specified default
+ for other VLANs."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.2.1"
+ ::= { dot1qVlanStaticEntry 5 }
+
+dot1qVlanStaticRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "This object is used to manage to creation and deletion of
+ a VLAN, and is used to indicate the status of this entry.
+
+ To Creating and activate a VLAN, first select a unused VID for
+ dot1qVlanIndex and then set its dot1qVlanStaticRowStatus to
+ 'createAndGo'. The VLAN will be created in the device without
+ tagged or untagged ports. A default VLAN name is assigned and
+ the status is set to 'active'.
+
+ To configure tagged and untagged port members of the VLAN,
+ assign appropriate of dot1qVlanStaticTaggedPorts and
+ dot1qVlanStaticUntaggedPorts. A set operation takes effect
+ on the device immediately.
+
+ To delete a VLAN, select the VID for dot1qVlanIndex and set
+ dot1qVlanStaticRowStatus to 'destory'. The row and the
+ corresponding VLAN configurarion will be removed from the
+ device. VLAN 1 is the default VLAN and can never be deleted.
+ All untagged traffic falls into this VLAN by default.
+
+ 'createAndWait', 'notInService', 'notReady' have no effects."
+ ::= { dot1qVlanStaticEntry 6 }
+
+
+--dot1qVlanForbiddenEgressPorts OBJECT-TYPE
+-- SYNTAX PortList
+-- MAX-ACCESS read-create
+-- STATUS current
+-- DESCRIPTION
+-- "The set of ports which are prohibited by management
+-- from being included in the egress list for this VLAN.
+-- Changes to this object that cause a port to be included
+-- or excluded affect the per-port per-VLAN Registrar
+-- control for Registration Forbidden for the relevant
+-- GVRP state machine on each port. A port may not be
+-- added in this set if it is already a member of the set
+-- of ports in dot1qVlanStaticEgressPorts. The default
+-- value of this object is a string of zeros of appropriate
+-- length, excluding all ports from the forbidden set."
+-- REFERENCE
+-- "IEEE 802.1Q/D11 Section 12.7.7.3, 11.2.3.2.3"
+-- ::= { dot1qVlanStaticEntry 5 }
+
+-- -----------------------------------------------------------------------------
+-- GVRP configration
+-- -----------------------------------------------------------------------------
+dot1qGvrp OBJECT IDENTIFIER ::= { ieee8021qVlan 3 }
+
+dot1qGvrpStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable GVRP Protocol. "
+ DEFVAL { disabled }
+ ::= { dot1qGvrp 1 }
+
+
+dot1qPortGvrpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1qPortGvrpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per port control and status information
+ for GVRP configuration in the device."
+ ::= { dot1qGvrp 2 }
+
+dot1qPortGvrpEntry OBJECT-TYPE
+ SYNTAX Dot1qPortGvrpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling GVRP configuration for a port on the
+ device."
+ INDEX { dot1qPortGvrpIndex }
+ ::= { dot1qPortGvrpTable 1 }
+
+Dot1qPortGvrpEntry ::= SEQUENCE {
+ dot1qPortGvrpIndex INTEGER,
+ dot1qPortGvrpStatus INTEGER,
+ -- dot1qPortGvrpRegistrationMode INTEGER,
+ dot1qPortGarpJoinTimer TimeInterval,
+ dot1qPortGarpLeaveTimer TimeInterval,
+ dot1qPortGarpLeaveAllTimer TimeInterval
+}
+
+dot1qPortGvrpIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The port identifier."
+ ::= { dot1qPortGvrpEntry 1 }
+
+dot1qPortGvrpStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The state of GVRP operation on this port. The value enabled(1)
+ indicates that GVRP is enabled on this port, as long as
+ dot1qGvrpStatus is also enabled for this device. When disabled(2)
+ but dot1qGvrpStatus is still enabled for the device, GVRP is
+ disabled on this port: any GVRP packets received will be
+ silently discarded and no GVRP registrations will be propagated
+ from other ports. This object affects all GVRP Applicant and
+ Registrar state machines on this port. A transition from
+ disabled(2) to enabled(1) will cause a reset of all GVRP state
+ machines on this port."
+ DEFVAL { enabled }
+ ::= { dot1qPortGvrpEntry 2 }
+
+-- dot1qPortGvrpRegistrationMode OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- registrationFixed(1),
+-- registrationForbidden(2),
+-- registrationNormal(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Administrative controls"
+-- ::= { dot1qPortGvrpEntry 3 }
+
+dot1qPortGarpJoinTimer OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The GARP Join timer, in centiseconds."
+ DEFVAL { 20 }
+ ::= { dot1qPortGvrpEntry 3 }
+
+dot1qPortGarpLeaveTimer OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The GARP Leave time, in centiseconds."
+ DEFVAL { 60 }
+ ::= { dot1qPortGvrpEntry 4 }
+
+dot1qPortGarpLeaveAllTimer OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The GARP LeaveAll time, in centiseconds."
+ DEFVAL { 1000 }
+ ::= { dot1qPortGvrpEntry 5 }
+
+
+-- -----------------------------------------------------------------------------
+-- Vlan Current Configuration Table
+-- -----------------------------------------------------------------------------
+
+dot1qVlanCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1qVlanCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing information about currently configured
+ VLANs, either by (local or network) management, or dynamically
+ created as a result of GVRP requests received."
+ ::= { ieee8021qVlan 4 }
+
+dot1qVlanCurrentEntry OBJECT-TYPE
+ SYNTAX Dot1qVlanCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information for a VLAN configured into the device by
+ (local or network) management, or dynamically created
+ as a result of GVRP requests received."
+ INDEX { dot1qVlanCurrentIndex }
+ ::= { dot1qVlanCurrentTable 1 }
+
+Dot1qVlanCurrentEntry ::= SEQUENCE {
+ dot1qVlanCurrentIndex INTEGER,
+ dot1qVlanCurrentEgressPorts PortList,
+ dot1qVlanCurrentUntaggedPorts PortList,
+ dot1qVlanStatus INTEGER
+-- dot1qVlanPortFa1 VlanEgressMode,
+-- dot1qVlanPortFa2 VlanEgressMode,
+-- dot1qVlanPortFa3 VlanEgressMode,
+-- dot1qVlanPortFa4 VlanEgressMode,
+-- dot1qVlanPortFa5 VlanEgressMode,
+-- dot1qVlanPortFa6 VlanEgressMode,
+-- dot1qVlanPortFa7 VlanEgressMode,
+-- dot1qVlanPortGi8 VlanEgressMode,
+-- dot1qVlanPortGi9 VlanEgressMode,
+-- dot1qVlanPortGi10 VlanEgressMode
+}
+
+dot1qVlanCurrentIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The VLAN Identifier (VID) refering to this VLAN."
+ ::= { dot1qVlanCurrentEntry 1 }
+
+dot1qVlanCurrentEgressPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The set of ports which are transmitting traffic for
+ this VLAN as either tagged or untagged frames."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.2.1"
+ ::= { dot1qVlanCurrentEntry 2 }
+
+dot1qVlanCurrentUntaggedPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The set of ports which are transmitting traffic for
+ this VLAN as untagged frames."
+ REFERENCE "IEEE 802.1Q/D11 Section 12.10.2.1"
+ ::= { dot1qVlanCurrentEntry 3 }
+
+dot1qVlanStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ permanent(2),
+ dynamicGvrp(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This object indicates the status of this entry.
+ other(1) - this entry is currently in use but the
+ conditions under which it will remain so differ
+ from the following values.
+ permanent(2) - this entry, corresponding to an entry
+ in dot1qVlanStaticTable, is currently in use and
+ will remain so after the next reset of the
+ device. The port lists for this entry include
+ ports from the equivalent dot1qVlanStaticTable
+ entry and ports learnt dynamically.
+ dynamicGvrp(3) - this entry is currently in use
+ and will remain so until removed by GVRP. There
+ is no static entry for this VLAN and it will be
+ removed when the last port leaves the VLAN."
+ ::= { dot1qVlanCurrentEntry 4 }
+
+-- dot1qVlanPortFa1 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa1."
+-- ::= { dot1qVlanCurrentEntry 5 }
+--
+-- dot1qVlanPortFa2 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa2."
+-- ::= { dot1qVlanCurrentEntry 6 }
+--
+-- dot1qVlanPortFa3 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa3."
+-- ::= { dot1qVlanCurrentEntry 7 }
+--
+-- dot1qVlanPortFa4 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa4."
+-- ::= { dot1qVlanCurrentEntry 8 }
+--
+-- dot1qVlanPortFa5 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa5."
+-- ::= { dot1qVlanCurrentEntry 9 }
+--
+-- dot1qVlanPortFa6 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa6."
+-- ::= { dot1qVlanCurrentEntry 10 }
+--
+-- dot1qVlanPortFa7 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Fa7."
+-- ::= { dot1qVlanCurrentEntry 11 }
+--
+-- dot1qVlanPortGi8 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Gi8."
+-- ::= { dot1qVlanCurrentEntry 12 }
+--
+-- dot1qVlanPortGi9 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Gi9."
+-- ::= { dot1qVlanCurrentEntry 13 }
+--
+-- dot1qVlanPortGi10 OBJECT-TYPE
+-- SYNTAX VlanEgressMode
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The vlan egress mode of port Gi10"
+-- ::= { dot1qVlanCurrentEntry 14 }
+--
+
+---------------------------------------------------------------------------
+-- dot1qTunnel/Q-in-Q
+---------------------------------------------------------------------------
+dot1qTunnel OBJECT IDENTIFIER ::= { ieee8021qVlan 5 }
+dot1qTunnelEtherType OBJECT-TYPE
+ SYNTAX OCTET STRING(SIZE (2))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "ethertype/TPID"
+ DEFVAL { '8100'H }
+ ::= { dot1qTunnel 1 }
+
+dot1qTunnelPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1qTunnelPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per tunnel access or uplink port information in the device."
+ ::= { dot1qTunnel 2 }
+
+dot1qTunnelPortEntry OBJECT-TYPE
+ SYNTAX Dot1qTunnelPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling tunnel configuration for a port on the device."
+ INDEX { dot1qTunnelPortIndex }
+ ::= { dot1qTunnelPortTable 1 }
+
+Dot1qTunnelPortEntry ::= SEQUENCE {
+ dot1qTunnelPortIndex INTEGER,
+ dot1qTunnelPortMode INTEGER
+}
+
+dot1qTunnelPortIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The port identifier."
+ ::= { dot1qTunnelPortEntry 1 }
+
+dot1qTunnelPortMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ access(2),
+ uplink(3),
+ uplink-add-pvid(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Tunnel mode controls"
+ ::= { dot1qTunnelPortEntry 2 }
+
+---------------------------------------------------------------------------
+-- Private VLAN
+---------------------------------------------------------------------------
+privateVlan OBJECT IDENTIFIER ::= { vlan 3 }
+
+privateVlanIdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrivateVlanIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per Private VLAN ID information in the device."
+ ::= { privateVlan 1 }
+
+privateVlanIdEntry OBJECT-TYPE
+ SYNTAX PrivateVlanIdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling Private VLAN ID configuration on the device."
+ INDEX { privateVlanId }
+ ::= { privateVlanIdTable 1 }
+
+PrivateVlanIdEntry ::= SEQUENCE {
+ privateVlanId INTEGER,
+ privateVlanIdType INTEGER
+}
+
+privateVlanId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Private VLAN ID."
+ ::= { privateVlanIdEntry 1 }
+
+privateVlanIdType OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ community(2),
+ isolated(3),
+ primary(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN ID type controls"
+ ::= { privateVlanIdEntry 2 }
+
+privateVlanPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrivateVlanPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per Private VLAN Port information in the device."
+ ::= { privateVlan 2 }
+
+privateVlanPortEntry OBJECT-TYPE
+ SYNTAX PrivateVlanPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling Private VLAN Port configuration on the device."
+ INDEX { privateVlanPortIndex }
+ ::= { privateVlanPortTable 1 }
+
+PrivateVlanPortEntry ::= SEQUENCE {
+ privateVlanPortIndex INTEGER,
+ privateVlanPortMode INTEGER
+}
+
+privateVlanPortIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Private Port Index."
+ ::= { privateVlanPortEntry 1 }
+
+privateVlanPortMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ host(2),
+ promiscuous(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN Port mode controls"
+ ::= { privateVlanPortEntry 2 }
+
+privateVlanHostAssociationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrivateVlanHostAssociationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per Private VLAN host port association information in the device."
+ ::= { privateVlan 3 }
+
+privateVlanHostAssociationEntry OBJECT-TYPE
+ SYNTAX PrivateVlanHostAssociationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling Private VLAN host port association configuration on the device."
+ INDEX { privateVlanHostAssociationPortIndex }
+ ::= { privateVlanHostAssociationTable 1 }
+
+PrivateVlanHostAssociationEntry ::= SEQUENCE {
+ privateVlanHostAssociationPortIndex INTEGER,
+ privateVlanHostAssociationPrimaryVid INTEGER,
+ privateVlanHostAssociationSecondaryVid INTEGER
+}
+
+privateVlanHostAssociationPortIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Private Host Port Index."
+ ::= { privateVlanHostAssociationEntry 1 }
+
+privateVlanHostAssociationPrimaryVid OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN host Port association primary VLAN ID. If enter 0 then clear setting."
+ ::= { privateVlanHostAssociationEntry 2 }
+
+privateVlanHostAssociationSecondaryVid OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN host Port association secondary VLAN ID(isolated/community). If enter 0 then clear setting."
+ ::= { privateVlanHostAssociationEntry 3 }
+
+privateVlanMappingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrivateVlanMappingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing per Private VLAN promiscuous port mapping information in the device."
+ ::= { privateVlan 4 }
+
+privateVlanMappingEntry OBJECT-TYPE
+ SYNTAX PrivateVlanMappingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information controlling Private VLAN promiscuous port mapping configuration on the device."
+ INDEX { privateVlanMappingPromiscuousPortIndex }
+ ::= { privateVlanMappingTable 1 }
+
+PrivateVlanMappingEntry ::= SEQUENCE {
+ privateVlanMappingPromiscuousPortIndex INTEGER,
+ privateVlanMappingPrimaryVid INTEGER,
+ privateVlanMappingSecondaryVidList DisplayString
+}
+
+privateVlanMappingPromiscuousPortIndex OBJECT-TYPE
+ SYNTAX INTEGER(1..10)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Private Promiscuous Port Index."
+ ::= { privateVlanMappingEntry 1 }
+
+privateVlanMappingPrimaryVid OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN promiscuous Port mapping primary VLAN ID. If enter 0 then clear setting."
+ ::= { privateVlanMappingEntry 2 }
+
+privateVlanMappingSecondaryVidList OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-write
+ STATUS current
+ DESCRIPTION "Private VLAN promiscuous Port mapping secondary VLAN ID list. If enter zero-length string then clear setting."
+ ::= { privateVlanMappingEntry 3 }
+
+
+
+---------------------------------------------------------------------------
+-- Port-based vlan
+---------------------------------------------------------------------------
+--portBasedVlanTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF PortBasedVlanEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "A table containing per port control and status information
+-- for port-based VLAN configuration in the device."
+-- ::= { portBasedVlan 1 }
+--
+--portBasedVlanEntry OBJECT-TYPE
+-- SYNTAX PortBasedVlanEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Information controlling port-based VLAN configuration for
+-- a port on the device."
+-- INDEX { portIndex }
+-- ::= { portBasedVlanTable 1 }
+--
+--PortBasedVlanEntry ::= SEQUENCE {
+-- portIndex INTEGER,
+-- portPvid INTEGER,
+-- portEgressPortList PortList,
+-- portEgressMode INTEGER
+--}
+--
+--portIndex OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The port identifier."
+-- ::= { portBasedVlanEntry 1 }
+--
+--portPvid OBJECT-TYPE
+-- SYNTAX INTEGER(1..4094)
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The default Port VID, the VLAN ID assigned to an untagged
+-- frame or a Priority-Tagged frame received on the port."
+-- REFERENCE "IEEE 802.1Q/D11 Section 12.10.1.1"
+-- DEFVAL { 1 }
+-- ::= { portBasedVlanEntry 2 }
+--
+--portEgressPortList OBJECT-TYPE
+-- SYNTAX PortList
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The ports to which a frame can egress from this port."
+-- ::= { portBasedVlanEntry 3 }
+--
+--portEgressMode OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- untagged(1),
+-- tagged(2),
+-- unmodified(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "To configure if the frames egress from this port will be
+-- add a 802.1Q vlan tag or not."
+-- DEFVAL { untagged }
+-- ::= { portBasedVlanEntry 4 }
+
+
+-- -----------------------------------------------------------------------------
+-- trafficPrioritization
+-- -----------------------------------------------------------------------------
+
+qosPolicy OBJECT-TYPE
+ SYNTAX INTEGER {
+ weighteRoundRobin-8-4-2-1(1),
+ strictPriority(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)8,4,2,1 weight round robin scheme: the switch will follow
+ 8:4:2:1 rate to process priority queue from Hi to lowest queue.
+ This approach prevents the lower priotiry packets from being
+ starved out with only a slight delay to the higher priority
+ packets.
+
+ (2)Use the strict priority scheme: Queue with higher priority
+ will always be process first, while queue with lower priority
+ will only be processed when the higher priority queue is empty.
+ This approach can cause the lower priorities the be startved
+ out preventing them from transmitting any packets, but it
+ ensures that all high priority packets serviced as soon as
+ possible."
+ ::= { trafficPrioritization 1 }
+
+-- -----------------------------------------------------------------------------
+-- port default cos table
+-- -----------------------------------------------------------------------------
+qosPortDefaultCosTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF QosPortDefaultCosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ port default cos value."
+ ::= { trafficPrioritization 2 }
+
+qosPortDefaultCosEntry OBJECT-TYPE
+ SYNTAX QosPortDefaultCosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion
+ about port default cos value."
+ INDEX { qosPortNum }
+ ::= { qosPortDefaultCosTable 1 }
+
+QosPortDefaultCosEntry ::= SEQUENCE {
+ qosPortNum Integer32,
+ qosPortTrust Integer32,
+ qosPortDefaultCos Integer32
+}
+
+qosPortNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port number."
+ ::= { qosPortDefaultCosEntry 1 }
+
+
+qosPortTrust OBJECT-TYPE
+ SYNTAX Integer32 {
+ cos-only(1),
+ dscp-only(2),
+ cos-first(3),
+ dscp-first(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Two kinds of priority information are token into
+ consideration when a packet is processed. One is COS,
+ the IEEE 802.3ac tag containing IEEE 802.1p priority
+ information, and the other is DSCP, the IPv4 Type of
+ Service/DiffServ field.
+ (1)COS only: the port priority will only follow the
+ COS priority that you have assigned.
+ (2)DSCP only: the port priority will only follow the
+ DSCP priority that you have assigned.
+ (3)COS first: the port priority will follow the COS
+ priority first, and then other priority rule.
+ (4)DSCP first: the port priority will follow the DSCP
+ priority first, and the other priority rule."
+ DEFVAL { cos-first }
+ ::= { qosPortDefaultCosEntry 2 }
+
+qosPortDefaultCos OBJECT-TYPE
+ SYNTAX Integer32(0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The port priority will follow the default port priority"
+ ::= { qosPortDefaultCosEntry 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- COS mapping table
+-- -----------------------------------------------------------------------------
+
+qosCOSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF QosCOSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ COS QOS."
+ ::= { trafficPrioritization 3 }
+
+qosCOSEntry OBJECT-TYPE
+ SYNTAX QosCOSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion about COS QOS."
+ INDEX { qosCOSPriority }
+ ::= { qosCOSTable 1 }
+
+QosCOSEntry ::= SEQUENCE {
+ qosCOSPriority Integer32,
+ qosCOS INTEGER
+}
+
+qosCOSPriority OBJECT-TYPE
+ SYNTAX Integer32(0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "COS priority."
+ ::= { qosCOSEntry 1 }
+
+qosCOS OBJECT-TYPE
+ SYNTAX INTEGER {
+ low(0),
+ middle(1),
+ high(2),
+ highest(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The port priority will follow the COS priority
+ that you have assigned (0)low, (1)middle, (2)high,
+ or (3)highest."
+ ::= { qosCOSEntry 2 }
+
+
+-- -----------------------------------------------------------------------------
+-- DSCP mapping table
+-- -----------------------------------------------------------------------------
+
+qosDscpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF QosDscpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration about
+ DSCP QOS."
+ ::= { trafficPrioritization 4 }
+
+qosDscpEntry OBJECT-TYPE
+ SYNTAX QosDscpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion
+ about DSCP QOS."
+ INDEX { qosDscpPriority }
+ ::= { qosDscpTable 1 }
+
+QosDscpEntry ::= SEQUENCE {
+ qosDscpPriority Integer32,
+ qosDscp INTEGER
+}
+
+qosDscpPriority OBJECT-TYPE
+ SYNTAX Integer32(0..63)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Dscp priority."
+ ::= { qosDscpEntry 1 }
+
+qosDscp OBJECT-TYPE
+ SYNTAX INTEGER {
+ low(0),
+ middle(1),
+ high(2),
+ highest(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The port priority will follow the Dscp priority
+ that you have assigned
+ (0)low (1)middle, (2)high, (3)highest."
+ ::= { qosDscpEntry 2 }
+
+-- -----------------------------------------------------------------------------
+-- multicastFiltering
+-- -----------------------------------------------------------------------------
+
+igmpQuery OBJECT IDENTIFIER ::= { multicastFiltering 1 }
+igmpSnooping OBJECT IDENTIFIER ::= { multicastFiltering 2 }
+unknownMulticast OBJECT IDENTIFIER ::= { multicastFiltering 3 }
+
+-- -----------------------------------------------------------------------------
+-- IGMP Query
+-- -----------------------------------------------------------------------------
+
+igmpQueryVersion OBJECT-TYPE
+ SYNTAX INTEGER {
+ version1(1),
+ version2(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)IGMP Query version 1.
+ (2)IGMP Query version 2."
+ ::= { igmpQuery 1 }
+
+igmpQueryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)enable IGMP Query on management vlan.
+ (2)disable IGMP Query."
+ ::= { igmpQuery 2 }
+
+igmpQueryInterval OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The interval between General Queries sent
+ by this Querier in seconds."
+ DEFVAL { 125 }
+ ::= { igmpQuery 3 }
+
+igmpQueryMaxResponseTime OBJECT-TYPE
+ SYNTAX Integer32 (1..25)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Max Respocse Time is meaningful only in
+ Membership Query messages, and specifies
+ the maximum allowed time before sending
+ a responding report in seconds."
+ DEFVAL { 10 }
+ ::= { igmpQuery 4 }
+
+--igmpQueryStatus OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- auto(1),
+-- enabled(2),
+-- disabled(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "(1)Detect querier automatically.
+-- (2)Force to be a querier.
+-- (3)Be a silence snooper.
+-- The mode of querier."
+-- ::= { igmpQuery 1 }
+
+--igmpQueryTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF IgmpQueryEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Table of descriptive information about IGMP query."
+-- ::= { igmpQuery 2 }
+
+--igmpQueryEntry OBJECT-TYPE
+-- SYNTAX IgmpQueryEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "An entry in the table, containing inforamtion
+-- about IGMP query."
+-- INDEX { igmpQueryEntryVID }
+-- ::= { igmpQueryTable 1 }
+
+--IgmpQueryEntry ::= SEQUENCE {
+-- igmpQueryEntryVID INTEGER,
+-- igmpQueryEntryStatus INTEGER
+-- }
+
+--igmpQueryEntryVID OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "The vlan id where igmp snooping to be configured"
+-- ::= { igmpQueryEntry 1 }
+
+--igmpQueryEntryStatus OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- auto(1),
+-- enabled(2),
+-- disabled(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION
+-- "The state of igmp Query operation on the vlan
+-- (1)Detect querier automatically.
+-- (2)Force to be a querier.
+-- (3)Be a silence snooper.
+-- (1) and (2) indicates that igmp Query is enabled on this
+-- vlan, as long as igmpQueryStatus is also enabled for this
+-- device. When disabled(3) but igmpQueryStatus is still
+-- enabled for the device, igmp Query is disabled on this vlan."
+-- DEFVAL { 1 }
+-- ::= { igmpQueryEntry 2 }
+
+
+-- -----------------------------------------------------------------------------
+-- IGMP Snooping
+-- -----------------------------------------------------------------------------
+igmpSnoopingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter to enable or disable IGMP snooping on the device.
+ When enabled, the device will examine IGMP packets and set
+ up filters for multicast traffic.
+
+ The Internet Group Management Protocol (IGMP) is an internal
+ protocol of the Internet Protocol (IP) suite. IP manages
+ multicast traffic by using switches, routers, and hosts that
+ support IGMP. Enabling IGMP makes the device to gather
+ multicast group membership information by snooping IGMP
+ packets, which helps the device switch IP multicast traffic
+ to the ports where group members exist instead of flooding the
+ traffic to every ports.
+
+ IGMP have three fundamental types of message as follows:
+
+ Message Description
+ --------------------------------------------------------------
+ Query A message sent from the querier (IGMP router or switch)
+ asking for responses from each host belonging to a
+ multicast group.
+
+ Report A message sent by a host to the querier to indicate
+ that the host wants to be or is a member of a given
+ group indicated in the report message.
+
+ Leave A message sent by a host to the querier to indicate
+ that the host has quit to be a member for a specific
+ multicast group.
+
+ The IGMP snooping functionality is configured on a vlan basis.
+ To enable or disable IGMP snooping on vlans:
+ 1. set igmpSnoopingStatus to enable(1) or disable(2).
+ 2. specify on which vlan IGMP snooping works by configuring
+ each entries in the igmpSnoopingTable.
+
+ As a result, you can turn on or off IGMP snooping functionality
+ by setting igmpSnoopingStatus while keeping the configuration
+ for each vlan. Or you can turn on or off IGMP snooping for a
+ specific vlan in igmpSnoopingTable with the statuses on other
+ vlan untouched."
+ ::= { igmpSnooping 1 }
+
+
+-- -----------------------------------------------------------------------------
+-- igmpSnoopingTable
+-- -----------------------------------------------------------------------------
+igmpSnoopingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IgmpSnoopingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about on which vlan is IGMP
+ snooping enabled."
+ ::= { igmpSnooping 2 }
+
+igmpSnoopingEntry OBJECT-TYPE
+ SYNTAX IgmpSnoopingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Inforamtion enabling or disabling IGMP snooping on a vlan."
+ INDEX { igmpSnoopingEntryVID }
+ ::= { igmpSnoopingTable 1 }
+
+IgmpSnoopingEntry ::= SEQUENCE {
+ igmpSnoopingEntryVID INTEGER,
+ igmpSnoopingEntryStatus INTEGER
+}
+
+igmpSnoopingEntryVID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The vlan id."
+ ::= { igmpSnoopingEntry 1 }
+
+igmpSnoopingEntryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The state of igmp snooping functionality on a vlan.
+ Set to enabled(1) indicates that igmp snooping is enabled on
+ the vlan. When igmpSnoopingStatus is also turned on, each IGMP
+ packets on the vlan will be processed.
+ When disabled(2) with igmpSnoopingStatus enabled, igmp packets
+ will not be processed and be propagated to other member ports
+ of the vlan.
+ A transition from disabled(2) to enabled(1) will cause a reset
+ of all igmp snooping information on this vlan."
+ DEFVAL { 2 }
+ ::= { igmpSnoopingEntry 2 }
+
+-- -----------------------------------------------------------------------------
+-- igmpSnoopingGroupTable
+-- -----------------------------------------------------------------------------
+igmpSnoopingGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IgmpSnoopingGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about IGMP snooped multicast
+ groups."
+ ::= { igmpSnooping 3 }
+
+igmpSnoopingGroupEntry OBJECT-TYPE
+ SYNTAX IgmpSnoopingGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information containing a multicast group and its member ports."
+ INDEX { igmpSnoopingGroupEntryVID, igmpSnoopingGroupEntryIPAddr }
+ ::= { igmpSnoopingGroupTable 1 }
+
+IgmpSnoopingGroupEntry ::= SEQUENCE {
+ igmpSnoopingGroupEntryVID INTEGER,
+ igmpSnoopingGroupEntryIPAddr IpAddress,
+ igmpSnoopingGroupEntryMembers PortList
+}
+
+igmpSnoopingGroupEntryVID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The VLAN ID of an IGMP entry."
+ ::= { igmpSnoopingGroupEntry 1 }
+
+igmpSnoopingGroupEntryIPAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The multicast group IP address."
+ ::= { igmpSnoopingGroupEntry 2 }
+
+igmpSnoopingGroupEntryMembers OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The member ports of the group."
+ ::= { igmpSnoopingGroupEntry 3 }
+
+-- -----------------------------------------------------------------------------
+-- unknownMulticast
+-- -----------------------------------------------------------------------------
+
+unknownMulticastStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ source-only-learning(1),
+ discard(2),
+ flood(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select IGMP Unknown Multicast policy.
+ (1) Send to Query Ports: The device sends the packets with
+ an unknown MAC/IP Multicast address to query ports
+ (2) Discard: The device discards all packets with an unknown
+ MAC/IP Multicast address.
+ (3) Send to All Ports: The device sends the packets with
+ an unknown MAC/IP Multicast address to all ports. "
+ DEFVAL { 3 }
+ ::= { unknownMulticast 1 }
+
+-- -----------------------------------------------------------------------------
+-- snmp
+-- -----------------------------------------------------------------------------
+
+-- To be available in pharse II
+--snmpAgentMode OBJECT-TYPE
+-- SYNTAX INTEGER {
+-- v1v2Conly(1),
+-- v3(2),
+-- v1v2Cv3(3)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The Agent mode of snmp agent.
+-- (1) SNMPV1/V2C Only.
+-- (2) SNMPV3.
+-- (3) SNMPV1/V2C/V3"
+-- ::= { snmp 1 }
+
+--snmpSystemName OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..64))
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The system name."
+-- ::= { snmp 2 }
+
+--snmpSystemLocation OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..64))
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The system location."
+-- ::= { snmp 3 }
+
+--snmpSystemContact OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..64))
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "The contact information of system."
+-- ::= { snmp 4 }
+
+-- -----------------------------------------------------------------------------
+-- snmpCommunityStringTable
+-- -----------------------------------------------------------------------------
+
+snmpCommunityStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnmpCommunityStringEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of information configuring community strings of
+ SNMP agent.
+
+ An SNMP community string is a text string that acts as
+ a password. It is used to authenticate messages that
+ are sent between the management station (the SNMP manager)
+ and the device (the SNMP agent). The community string is
+ included in every packet that is transmitted between the
+ SNMP manager and the SNMP agent.
+
+ After receiving an SNMP request, the SNMP agent compares
+ the community string in the request to the community
+ strings that are configured for the agent. The requests
+ are valid under these circumstances:
+
+ - Only SNMP Get and Get-next requests are valid if the
+ community string in the request matches the read-only
+ community.
+
+ - SNMP Get, Get-next, and Set requests are valid if the
+ community string in the request matches the agent's
+ read-write community.
+
+ By default, 'public' is the read-only community and
+ 'private' is the read-write community. Total 4 community
+ strings are allowed to configure in the device."
+ ::= { snmp 1 }
+
+snmpCommunityStringEntry OBJECT-TYPE
+ SYNTAX SnmpCommunityStringEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Inforamtion configuring an community string."
+ INDEX { snmpCommunityStringIndex }
+ ::= { snmpCommunityStringTable 1 }
+
+SnmpCommunityStringEntry ::= SEQUENCE {
+ snmpCommunityStringIndex Integer32,
+ snmpCommunityStringName DisplayString,
+ snmpCommunityStringPrivilege INTEGER,
+ snmpCommunityStringStatus INTEGER
+}
+
+snmpCommunityStringIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of community string."
+ ::= { snmpCommunityStringEntry 1 }
+
+snmpCommunityStringName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "A community string with maximum 32 characters."
+ ::= { snmpCommunityStringEntry 2 }
+
+snmpCommunityStringPrivilege OBJECT-TYPE
+ SYNTAX INTEGER {
+ ro(1),
+ rw(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The access privilege of the community string."
+ ::= { snmpCommunityStringEntry 3 }
+
+snmpCommunityStringStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of this entry. Set to (5)createAndWait
+ to create a new entry. A new entry or an active
+ entry can be edited. Once an entry is modified,
+ its status becomes (3)notReady. Set to (1)active
+ to apply the modification to the switch. An entry
+ can be removed by setting to (6)destory."
+ ::= { snmpCommunityStringEntry 4 }
+
+
+-- -----------------------------------------------------------------------------
+-- snmpV3UserTable
+-- -----------------------------------------------------------------------------
+
+snmpV3UserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnmpV3UserEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive and information about trap servers.
+ A trap server is the recipient of an SNMP trap. The device
+ does not send a trap unless it knows to which station it
+ should send a trap."
+ ::= { snmp 2 }
+
+snmpV3UserEntry OBJECT-TYPE
+ SYNTAX SnmpV3UserEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion about a
+ trap server of SNMP agent."
+ INDEX { snmpTrapServerIndex }
+ ::= { snmpV3UserTable 1 }
+
+SnmpV3UserEntry ::= SEQUENCE {
+ snmpV3UserIndex Integer32,
+ snmpV3UserName DisplayString,
+ snmpV3UserSecurityLevel INTEGER,
+ snmpV3UserAuthProtocol INTEGER,
+ snmpV3UserAuthPassword DisplayString,
+ snmpV3UserDesPassword DisplayString,
+ snmpV3UserStatus RowStatus
+}
+
+snmpV3UserIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of snmp v3 user."
+ ::= { snmpV3UserEntry 1 }
+
+snmpV3UserName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION ""
+ ::= { snmpV3UserEntry 2 }
+
+snmpV3UserSecurityLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ noauth(1),
+ auth(2),
+ priv(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Specifiy the authentication and privacy level
+ - noauth(1) no authentication and no privacy.
+ - auth(2) enables MD5 or SHA packet authentication.
+ - priv(3) enables MD5 or SHA packet authentication
+ and DES packet encryption."
+ ::= { snmpV3UserEntry 3 }
+
+snmpV3UserAuthProtocol OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ md5(2),
+ sha(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "MD5(Message Digest 5) or SHA (Secure Hash Algorithm)"
+ ::= { snmpV3UserEntry 4 }
+
+snmpV3UserAuthPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION ""
+ ::= { snmpV3UserEntry 5 }
+
+snmpV3UserDesPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION ""
+ ::= { snmpV3UserEntry 6 }
+
+snmpV3UserStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION ""
+ ::= { snmpV3UserEntry 7 }
+
+
+-- -----------------------------------------------------------------------------
+-- snmpTrapServerTable
+-- -----------------------------------------------------------------------------
+
+snmpTrapServerEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "To enable, disable snmp trap functionality.
+
+ SNMPv1 traps are defined in RFC 1157, and SNMPv2c trap is
+ defined as NOTIFICATION. SNMP traps enable this device to
+ notify the management station of significant events by way
+ of an unsolicited SNMP message. After the manager receives
+ the event, the manager displays it and can choose to take
+ an action based on the event. For instance, the manager can
+ poll the agent directly, or poll other associated device
+ agents to get a better understanding of the event."
+ ::= { snmp 3 }
+
+
+snmpTrapServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnmpTrapServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive and information about trap servers.
+ A trap server is the recipient of an SNMP trap. The device
+ does not send a trap unless it knows to which station it
+ should send a trap."
+ ::= { snmp 4 }
+
+snmpTrapServerEntry OBJECT-TYPE
+ SYNTAX SnmpTrapServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table, containing inforamtion about a
+ trap server of SNMP agent."
+ INDEX { snmpTrapServerIndex }
+ ::= { snmpTrapServerTable 1 }
+
+SnmpTrapServerEntry ::= SEQUENCE {
+ snmpTrapServerIndex Integer32,
+ snmpTrapServerIPAddr IpAddress,
+ snmpTrapServerTrapComm DisplayString,
+ snmpTrapServerTrapVer INTEGER,
+ snmpTrapServerStatus RowStatus
+}
+
+snmpTrapServerIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of trap server."
+ ::= { snmpTrapServerEntry 1 }
+
+snmpTrapServerIPAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Trap Server IP Address."
+ ::= { snmpTrapServerEntry 2 }
+
+snmpTrapServerTrapComm OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The community string of trap server. The password-like string
+ will be sent with the notification operation."
+ ::= { snmpTrapServerEntry 3 }
+
+snmpTrapServerTrapVer OBJECT-TYPE
+ SYNTAX INTEGER {
+ v1(1),
+ v2c(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The trap version."
+ ::= { snmpTrapServerEntry 4 }
+
+snmpTrapServerStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of this entry. Set to (5)createAndWait
+ to create a new entry. A new entry or an active
+ entry can be edited. Once an entry is modified,
+ its status becomes (3)notReady. Set to (1)active
+ to apply the modification to the device. An entry
+ can be removed by setting to (6)destory."
+ ::= { snmpTrapServerEntry 5 }
+
+
+-- -----------------------------------------------------------------------------
+-- security
+-- -----------------------------------------------------------------------------
+portSecurity OBJECT IDENTIFIER ::= { security 1 }
+ipSecurity OBJECT IDENTIFIER ::= { security 2 }
+dot1x OBJECT IDENTIFIER ::= { security 3 }
+--macFiltering OBJECT IDENTIFIER ::= { security 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- portSecurityStatusTable
+-- -----------------------------------------------------------------------------
+
+portSecurityStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortSecurityStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing information about port security status on
+ each port.
+
+ Port security prevents a port from address learning. Only
+ those MAC addresses that are configured by management are
+ allowed to access the switch or transmit/receive through the
+ port. Upto 10 MAC addresses can assigned to each port by adding
+ address entries to portSecurityMacTable or macAddrTable.
+
+ If the port security functionality is enabled but without any
+ MAC address configured on a port, no traffic can access the
+ switch or transmit/receive from the port."
+ ::= { portSecurity 1 }
+
+portSecurityStatusEntry OBJECT-TYPE
+ SYNTAX PortSecurityStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry configuring port security for a port."
+ INDEX { portSecurityPortIndex }
+ ::= { portSecurityStatusTable 1 }
+
+PortSecurityStatusEntry ::= SEQUENCE {
+ portSecurityPortIndex Integer32,
+ portSecurityPortStatus INTEGER
+}
+
+portSecurityPortIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The port id."
+ ::= { portSecurityStatusEntry 1 }
+
+portSecurityPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "(1)enable port security on this port.
+ (2)disable port security on this port."
+ ::= { portSecurityStatusEntry 2 }
+
+
+-- -----------------------------------------------------------------------------
+-- portSecurityMacTable
+-- -----------------------------------------------------------------------------
+
+portSecurityMacTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortSecurityMacEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table configuring static unicast MAC address for each port.
+
+ When you add a static MAC address, it remains in the switch's
+ address table, regardless of whether the device is physically
+ connected to the switch.
+
+ With enabling port security in portSecurityStatusTable, only
+ those MAC addresses configured in portSecurityMacTable are
+ allowed to access the switch or transmit/receive through the
+ port."
+ ::= { portSecurity 2 }
+
+portSecurityMacEntry OBJECT-TYPE
+ SYNTAX PortSecurityMacEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry configuring a static unicast MAC addresses on a port."
+ INDEX { portSecurityMacIndex }
+ ::= { portSecurityMacTable 1 }
+
+PortSecurityMacEntry ::= SEQUENCE {
+ portSecurityMacIndex Integer32,
+ portSecurityPort Integer32,
+ portSecurityVlanIndex Integer32,
+ portSecurityMac MacAddress,
+ portSecurityMacStatus RowStatus
+}
+
+portSecurityMacIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of MAC."
+ ::= { portSecurityMacEntry 1 }
+
+portSecurityPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The port id."
+ ::= { portSecurityMacEntry 2 }
+
+portSecurityVlanIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The vlan id where the MAC address belongs to."
+ ::= { portSecurityMacEntry 3 }
+
+portSecurityMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "MAC address of the entry."
+ ::= { portSecurityMacEntry 4 }
+
+portSecurityMacStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The status of this entry. Set to (5)createAndWait
+ to create a new entry. A new entry or an active
+ entry can be edited. Once an entry is modified,
+ its status becomes (3)notReady. Set to (1)active
+ to apply the modification to the device. An entry
+ can be removed by setting to (6)destory."
+ ::= { portSecurityMacEntry 5 }
+
+
+-- -----------------------------------------------------------------------------
+-- ipSecurity
+-- -----------------------------------------------------------------------------
+
+ipSecurityStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable or disable IP security functionality.
+
+ IP security allows you to assign specific IP addresses that
+ are permitted to access the device for securing switch
+ management. Set to (1) to enable IP Security. set to (2) to
+ disable IP Security.
+
+ Enabling IP Security without any entries configured in the
+ ipSecurityTable has no effect on the access traffic."
+ ::= { ipSecurity 1 }
+
+ipSecurityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpSecurityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table configuring IP addresses that can access and manage the
+ device through network, such as telnet, web or SNMP.
+
+ Please note that enabling IP security function but without
+ adding the IP address of your current management station will
+ break current management connection."
+ ::= { ipSecurity 2 }
+
+ipSecurityEntry OBJECT-TYPE
+ SYNTAX IpSecurityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry configuring an security IP address."
+ INDEX { ipSecurityIndex }
+ ::= { ipSecurityTable 1 }
+
+IpSecurityEntry ::= SEQUENCE {
+ ipSecurityIndex Integer32,
+ ipSecurityIP IpAddress,
+ ipSecurityRowStatus RowStatus
+}
+
+ipSecurityIndex OBJECT-TYPE
+ SYNTAX Integer32(1..10)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of IP address entry."
+ ::= { ipSecurityEntry 1 }
+
+ipSecurityIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "An IP address that can access and manage the device."
+ ::= { ipSecurityEntry 2 }
+
+ipSecurityRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "This object is used to manage to creation and deletion of
+ a authorized IP address, and is used to indicate the status
+ of this entry. A empty entry or an active entry can be edited.
+ Once an entry is modified, its status becomes (3)notReady.
+ Set to (1)active to apply the modification to the device. An
+ entry can be removed by setting to (6)destory."
+ ::= { ipSecurityEntry 3 }
+
+
+--ipSecurityIP1 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 2 }
+
+--ipSecurityIP2 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 3 }
+
+--ipSecurityIP3 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 4 }
+
+--ipSecurityIP4 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 5 }
+
+--ipSecurityIP5 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 6 }
+
+--ipSecurityIP6 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 7 }
+
+--ipSecurityIP7 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 8 }
+
+--ipSecurityIP8 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 9 }
+
+--ipSecurityIP9 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 10 }
+
+--ipSecurityIP10 OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "This IP address can access and manage the device."
+-- ::= { ipSecurity 11 }
+
+
+-- -----------------------------------------------------------------------------
+-- macFilteringTable, NOT SUPPORT
+-- -----------------------------------------------------------------------------
+
+--macFilteringTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF MACFilteringEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Table of descriptive information about
+-- MAC filter configuration.
+-- MAC address filtering allows the switch to drop
+-- unwanted traffic. Traffic is filtered based on
+-- the destination addresses. For example, if your
+-- network is congested because of high utilization
+-- from one MAC address, you can filter all traffic
+-- transmitted to that MAC address, restoring network
+-- flow while you troubleshoot the problem."
+-- ::= { macFiltering 1}
+--
+--macFilteringEntry OBJECT-TYPE
+-- SYNTAX MACFilteringEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "An entry in the table, containing inforamtion
+-- about MAC filter configuration."
+-- INDEX { macFilteringIndex }
+-- ::= { macFilteringTable 1 }
+--
+--MACFilteringEntry ::= SEQUENCE
+--{
+-- macFilteringIndex Integer32,
+-- macFilteringAddr MacAddress,
+-- macFilteringStatus INTEGER
+--}
+--
+--macFilteringIndex OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Index of MAC."
+-- ::= { macFilteringEntry 1 }
+--
+--macFilteringAddr OBJECT-TYPE
+-- SYNTAX MacAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "MAC address of the entry."
+-- ::= { macFilteringEntry 2 }
+--
+--macFilteringStatus OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- valid(1),
+-- creatrequest(2),
+-- undercreation(3),
+-- invalid(4)
+-- }
+-- MAX-ACCESS read-create
+-- STATUS current
+-- DESCRIPTION "The status of this entry. If this object is not equal to valid(1), all associated
+-- MAC entries shall be deleted by the agent."
+-- ::= { macFilteringEntry 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- dot1x
+-- -----------------------------------------------------------------------------
+
+dot1xStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IEEE802.1x protocol function status.
+ (1) IEEE802.1x protocol function is enabled.
+ (2) IEEE802.1x protocol function is disabled.
+ 802.1x makes use of the physical access characteristics
+ of IEEE802 LAN infrastructures in order to provide a
+ means of authenticating and authorizing devices attached
+ to a LAN port that has point-to-point connection
+ characteristics, and of preventing access to that port
+ in cases in which the authentication and authorization
+ process fails."
+ ::= { dot1x 1 }
+
+dot1xAuthentication OBJECT-TYPE
+ SYNTAX INTEGER {
+ local(1),
+ radius(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 2 }
+
+-- -----------------------------------------------------------------------------
+-- radiusServerTable
+-- -----------------------------------------------------------------------------
+radiusServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RadiusServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 3 }
+
+radiusServerEntry OBJECT-TYPE
+ SYNTAX RadiusServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ INDEX { radiusServerIndex }
+ ::= { radiusServerTable 1 }
+
+RadiusServerEntry ::= SEQUENCE {
+ radiusServerIndex Integer32,
+ radiusServerIp IpAddress,
+ radiusServerServerPort Integer32,
+ radiusServerAccountingPort Integer32,
+ radiusServerSharedKey DisplayString
+-- radiusServerStatus RowStatus
+}
+
+radiusServerIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of Radius server configuration."
+ ::= { radiusServerEntry 1 }
+
+radiusServerIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP address of this radius server."
+ ::= { radiusServerEntry 2 }
+
+radiusServerServerPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The UDP port number used by the authentication server
+ to authenticate."
+ ::= { radiusServerEntry 3 }
+
+radiusServerAccountingPort OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Accounting Port: The UDP port number used by the authentication
+ server to retrieve accounting information."
+ ::= { radiusServerEntry 4 }
+
+radiusServerSharedKey OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "A key shared between this switch and authentication server."
+ ::= { radiusServerEntry 5 }
+
+--radiusServerStatus OBJECT-TYPE
+-- SYNTAX RowStatus
+-- MAX-ACCESS read-create
+-- STATUS current
+-- DESCRIPTION "."
+-- ::= { radiusServerEntry 6 }
+
+
+-- -----------------------------------------------------------------------------
+-- dot1xLocalUserTable
+-- -----------------------------------------------------------------------------
+dot1xLocalUserTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1xLocalUserEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 4 }
+
+dot1xLocalUserEntry OBJECT-TYPE
+ SYNTAX Dot1xLocalUserEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ INDEX { dot1xLocalUserIndex }
+ ::= { dot1xLocalUserTable 1 }
+
+Dot1xLocalUserEntry ::= SEQUENCE {
+ dot1xLocalUserIndex Integer32,
+ dot1xLocalUserName DisplayString,
+ dot1xLocalUserPassword DisplayString,
+ dot1xLocalUserVid Integer32
+ --dot1xLocalUserStatus RowStatus
+}
+
+dot1xLocalUserIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xLocalUserEntry 1 }
+
+dot1xLocalUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "set this field to empty to remove this user config."
+ ::= { dot1xLocalUserEntry 2 }
+
+dot1xLocalUserPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xLocalUserEntry 3 }
+
+dot1xLocalUserVid OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xLocalUserEntry 4 }
+
+--dot1xLocalUserStatus OBJECT-TYPE
+ --SYNTAX RowStatus
+ --MAX-ACCESS read-create
+ --STATUS current
+ --DESCRIPTION "."
+ --::= { dot1xLocalUserEntry 5 }
+
+-- -----------------------------------------------------------------------------
+-- dot1xPortConfigTable
+-- -----------------------------------------------------------------------------
+dot1xPortConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1xPortConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 5 }
+
+dot1xPortConfigEntry OBJECT-TYPE
+ SYNTAX Dot1xPortConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ INDEX { dot1xPortConfigIndex }
+ ::= { dot1xPortConfigTable 1 }
+
+Dot1xPortConfigEntry ::= SEQUENCE {
+ dot1xPortConfigIndex Integer32,
+ dot1xPortAuthControl INTEGER,
+ dot1xPortReauthentication INTEGER,
+ dot1xPortMaxRequest INTEGER,
+ dot1xPortGuestVlan INTEGER,
+ dot1xPortHostMode INTEGER,
+ dot1xPortAdminDirection INTEGER,
+ dot1xPortConfigSetDefault INTEGER,
+ dot1xPortReinitialize INTEGER,
+ dot1xPortClientReauth INTEGER
+}
+
+dot1xPortConfigIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 1 }
+
+dot1xPortAuthControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ forceAuthorized(2),
+ forceUnauthorized(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 2 }
+
+dot1xPortReauthentication OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 3 }
+
+dot1xPortMaxRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 4 }
+
+dot1xPortGuestVlan OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 5 }
+
+dot1xPortHostMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ single(1),
+ multiple(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 6 }
+
+dot1xPortAdminDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ both(1),
+ in(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 7 }
+
+dot1xPortConfigSetDefault OBJECT-TYPE
+ SYNTAX INTEGER {
+ apply(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 8 }
+
+dot1xPortReinitialize OBJECT-TYPE
+ SYNTAX INTEGER {
+ apply(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 9 }
+
+dot1xPortClientReauth OBJECT-TYPE
+ SYNTAX INTEGER {
+ apply(1)
+ }
+ MAX-ACCESS write-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortConfigEntry 10 }
+
+
+-- -----------------------------------------------------------------------------
+-- dot1xPortTimeoutConfigTable
+-- -----------------------------------------------------------------------------
+dot1xPortTimeoutConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1xPortTimeoutConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 6 }
+
+dot1xPortTimeoutConfigEntry OBJECT-TYPE
+ SYNTAX Dot1xPortTimeoutConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ INDEX { dot1xPortTimeoutIndex }
+ ::= { dot1xPortTimeoutConfigTable 1 }
+
+Dot1xPortTimeoutConfigEntry ::= SEQUENCE {
+ dot1xPortTimeoutIndex Integer32,
+ dot1xPortReauthPeriod Integer32,
+ dot1xPortQuietPeriod Integer32,
+ dot1xPortTxPeriod Integer32,
+ dot1xPortSupplicantTimeout Integer32,
+ dot1xPortServerTimeout Integer32
+}
+
+dot1xPortTimeoutIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 1 }
+
+dot1xPortReauthPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 2 }
+
+dot1xPortQuietPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 3 }
+
+dot1xPortTxPeriod OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 4 }
+
+dot1xPortSupplicantTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 5 }
+
+dot1xPortServerTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortTimeoutConfigEntry 6 }
+
+-- -----------------------------------------------------------------------------
+-- dot1xPortStatusTable
+-- -----------------------------------------------------------------------------
+dot1xPortStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dot1xPortStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1x 7 }
+
+dot1xPortStatusEntry OBJECT-TYPE
+ SYNTAX Dot1xPortStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ INDEX { dot1xPortStatusIndex }
+ ::= { dot1xPortStatusTable 1 }
+
+Dot1xPortStatusEntry ::= SEQUENCE {
+ dot1xPortStatusIndex Integer32,
+ dot1xPortCtrl INTEGER,
+ dot1xPortAuthStatus INTEGER,
+ dot1xPortAuthSupplicant MacAddress,
+ dot1xPortOperDirection INTEGER
+}
+
+dot1xPortStatusIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortStatusEntry 1 }
+
+dot1xPortCtrl OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ forceAuthorized(2),
+ forceUnauthorized(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortStatusEntry 2 }
+
+dot1xPortAuthStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ authorized(1),
+ unauthorized(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortStatusEntry 3 }
+
+dot1xPortAuthSupplicant OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortStatusEntry 4 }
+
+dot1xPortOperDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ both(1),
+ in(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "."
+ ::= { dot1xPortStatusEntry 5 }
+
+
+--radiusServerSetting OBJECT IDENTIFIER ::= { ieee8021x 1 }
+--portAuthConfiguration OBJECT IDENTIFIER ::= { ieee8021x 2 }
+
+--radius8021xProtocolStatus OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- enabled(1),
+-- disabled(2)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "IEEE802.1x protocol function status.
+-- (1) IEEE802.1x protocol function is enabled.
+-- (2) IEEE802.1x protocol function is disabled.
+-- 802.1x makes use of the physical access characteristics
+-- of IEEE802 LAN infrastructures in order to provide a
+-- means of authenticating and authorizing devices attached
+-- to a LAN port that has point-to-point connection
+-- characteristics, and of preventing access to that port
+-- in cases in which the authentication and authorization
+-- process fails."
+-- ::= { radiusServerSetting 1 }
+
+--radiusServerIP OBJECT-TYPE
+-- SYNTAX IpAddress
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Radius Server IP Address: the ip address of the authentication server."
+-- ::= { radiusServerSetting 2 }
+
+--radiusServerPort OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Server Port: The UDP port number used by the authentication server to authenticate."
+-- ::= { radiusServerSetting 3 }
+--
+--radiusAccountingPort OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Accounting Port: The UDP port number used by the authentication server to retrieve
+-- accounting information. "
+-- ::= { radiusServerSetting 4 }
+--
+--radiusSharedKey OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..30))
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Shared Key: A key shared between this switch and authentication server."
+-- ::= { radiusServerSetting 5 }
+--
+--radiusNASIdentifier OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..30))
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "NAS Identifier: A string used to identify this switch."
+-- ::= { radiusServerSetting 6 }
+--
+--radiusMiscQuietPeriod OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Quiet Period: used to define periods of time during
+-- which it will not attempt to acquire a supplicant
+-- (Default time is 60 seconds)."
+-- ::= { radiusServerSetting 7 }
+--
+--radiusMiscTxPeriod OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Tx Period: used to determine when an EAPOL PDU is to
+-- be transmitted(Default value is 30 seconds)."
+-- ::= { radiusServerSetting 8 }
+--
+--radiusMiscSupplicantTimeout OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Supplicant Timeout: used to determine timeout conditions
+-- in the exchanges between the supplicant and
+-- authentication server(Default value is 30 seconds)."
+-- ::= { radiusServerSetting 9 }
+--
+--radiusMiscServerTimeout OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Server Timeout: used to determine timeout conditions
+-- in the exchanges between the authenticator and
+-- authentication server(Default value is 30 seconds)."
+-- ::= { radiusServerSetting 10}
+--
+--radiusMiscReAuthMax OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "ReAuthMax: used to determine the number of
+-- reauthentication attempts that are permitted
+-- before the specific port becomes unauthorized
+-- (Default value is 2 times)."
+-- ::= { radiusServerSetting 11}
+--
+--radiusMiscReauthPeriod OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "Reauth Period: used to determine a nonzero number
+-- of seconds between periodic reauthentication of
+-- the supplications(Default value is 3600 seconds)."
+-- ::= { radiusServerSetting 12}
+--
+--radiusPerPortCfgTable OBJECT-TYPE
+-- SYNTAX SEQUENCE OF RadiusPerPortCfgEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Table of descriptive information and configuration about
+-- Radius per port configuration."
+-- ::= { portAuthConfiguration 1}
+--
+--radiusPerPortCfgEntry OBJECT-TYPE
+-- SYNTAX RadiusPerPortCfgEntry
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "An entry in the table, containing inforamtion
+-- about Radius per port configuration."
+-- INDEX { radiusPerPortCfgIndex }
+-- ::= { radiusPerPortCfgTable 1 }
+--
+--RadiusPerPortCfgEntry ::= SEQUENCE
+--{
+-- radiusPerPortCfgIndex Integer32,
+-- radiusPerPortCfgPortName DisplayString,
+-- radiusPerPortCfgState INTEGER
+--}
+--
+--radiusPerPortCfgIndex OBJECT-TYPE
+-- SYNTAX Integer32
+-- MAX-ACCESS not-accessible
+-- STATUS current
+-- DESCRIPTION "Index of port."
+-- ::= { radiusPerPortCfgEntry 1 }
+--
+--radiusPerPortCfgPortName OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE(0..16))
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION "The name of port."
+-- ::= { radiusPerPortCfgEntry 2 }
+--
+--radiusPerPortCfgState OBJECT-TYPE
+-- SYNTAX INTEGER
+-- {
+-- reject(1),
+-- accept(2),
+-- authorize(3),
+-- disabled(4)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION "You can select the specific port and configure the
+-- authorization state. Each port can select four kinds
+-- of authorization state :
+-- Reject: force the specific port to be unauthorized.
+-- Accept: force the specific port to be authorized.
+-- Authorize: the state of the specific port was determinied by
+-- the outcome of the authentication.
+-- Disable: the specific port didn't support 802.1x function."
+-- ::= { radiusPerPortCfgEntry 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- Warning
+-- -----------------------------------------------------------------------------
+faultRelay OBJECT IDENTIFIER ::= { warning 1 }
+eventAndEmailWarning OBJECT IDENTIFIER ::= { warning 2 }
+hardwareStatus OBJECT IDENTIFIER ::= { warning 3 }
+
+eventSelection OBJECT IDENTIFIER ::= { eventAndEmailWarning 1 }
+sysLogConfiguration OBJECT IDENTIFIER ::= { eventAndEmailWarning 2 }
+smtpConfiguration OBJECT IDENTIFIER ::= { eventAndEmailWarning 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- Fault Relay
+-- -----------------------------------------------------------------------------
+faultRelayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FaultRelayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of configuration about fault relay.
+
+ A fault relay is able to control an output circuit which is
+ triggered by management defined fault events. There are two
+ fault relays in the device, each is controlled by an
+ faultRelayEntry in this table.
+
+ To configure a fault relay, first select the type of fault
+ event which will trigger the relay in faultSelection, and
+ then configure the related column.
+
+ Set faultRelayEntryStatus to active(1) to set the configuration
+ to the device."
+ ::= { faultRelay 1 }
+
+faultRelayEntry OBJECT-TYPE
+ SYNTAX FaultRelayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A entry controlling a fault relay configuration."
+ INDEX { faultRelayId }
+ ::= { faultRelayTable 1 }
+
+FaultRelayEntry ::= SEQUENCE {
+ faultRelayId INTEGER,
+ faultSelection INTEGER,
+ diConfig INTEGER,
+ dryOutputOnPeriodConfig INTEGER,
+ dryOutputOffPeriodConfig INTEGER,
+ powerFailureConfig INTEGER,
+ linkFailureConfig PortList,
+ pingFailureIP IpAddress,
+ pingResetTime INTEGER,
+ pingHoldTime INTEGER,
+ faultRelayEntryStatus INTEGER
+}
+
+faultRelayId OBJECT-TYPE
+ SYNTAX INTEGER {
+ relay1(1),
+ relay2(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Index of fault relay."
+ ::= { faultRelayEntry 1 }
+
+faultSelection OBJECT-TYPE
+ SYNTAX INTEGER {
+ diState(1),
+ dryOutput(2),
+ powerFailure(3),
+ linkFailure(4),
+ pingFailure(5),
+ superRingFailure(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select the type of fault event that triggers the relay.
+ To config a fault relay, first select the founction this
+ relay serves for, then configure the condition that
+ triggers the relay in detail. At last, set the
+ faultRelayEntryStatus to active(1) or nonActive(3) to
+ enable or disable the setting on the relay."
+ ::= { faultRelayEntry 2 }
+
+diConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ di1Low(1),
+ di1High(2),
+ di2Low(3),
+ di2High(4),
+ disable(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be triggered if digital input is low
+ or high."
+ ::= { faultRelayEntry 3 }
+
+dryOutputOnPeriodConfig OBJECT-TYPE
+ SYNTAX INTEGER(1..1000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be closed after a period (in seconds).
+ Together with dryOutputOffPeriodConfig, the fault relay can
+ be configured to continue on and off."
+ ::= { faultRelayEntry 4 }
+
+dryOutputOffPeriodConfig OBJECT-TYPE
+ SYNTAX INTEGER(1..1000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be opened after a period (in seconds).
+ Together with dryOutputOnPeriodConfig, the fault relay can
+ be configured to continue on and off."
+ ::= { faultRelayEntry 5 }
+
+
+powerFailureConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ power1(1),
+ power2(2),
+ any(255),
+ disable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be triggered if the configured
+ power fails. Any means either power 1 or power2 fails"
+ ::= { faultRelayEntry 6 }
+
+linkFailureConfig OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be trigger if any of the configured
+ links fails."
+ ::= { faultRelayEntry 7 }
+
+pingFailureIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fault relay will be trigger if fail to ping the assigned
+ IP address."
+ ::= { faultRelayEntry 8 }
+
+pingResetTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Reset the ping process after pingResetTime, and then wait
+ pingHoldTime to ping again. (optional)"
+ ::= { faultRelayEntry 9 }
+
+pingHoldTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Reset the ping process after pingResetTime, and then wait
+ pingHoldTime to ping again. (optional)"
+ ::= { faultRelayEntry 10 }
+
+faultRelayEntryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ configuring(2),
+ notActive(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Setting this object to active(1) to save the configuration
+ to the device. Setting this object to notActive(3) disable
+ the configuration.
+
+ The system returns active(1) or notActive when the settings
+ of the entry is enabled or disabled on the relay. And the
+ status becomes configuring(2) when the settings of the entry
+ are modified and not set to active(1) yet."
+ ::= { faultRelayEntry 11 }
+
+
+-- -----------------------------------------------------------------------------
+-- System Event Table
+-- -----------------------------------------------------------------------------
+
+systemEventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SystemEventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and controls the reactions
+ to system events.
+
+ Three types of reactions will be triggered: (1)logging in the
+ switch or send logs to remote syslog servers, (2)sending an
+ email, or (3)send an snmp trap. Each type of alert is configured
+ in sysLogConfiguration, smtpConfiguration, snmpTrapServerEnable
+ and snmpTrapServerTable."
+ ::= { eventSelection 1 }
+
+systemEventEntry OBJECT-TYPE
+ SYNTAX SystemEventEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "An entry containing type of system events."
+ INDEX { eventSystemEventIndex }
+ ::= { systemEventTable 1 }
+
+SystemEventEntry ::= SEQUENCE {
+ eventSystemEventIndex Integer32,
+ eventDeviceColdStartEvent AlertType,
+ eventDeviceWarmStartEvent AlertType,
+ eventAuthenticationFailureEvent AlertType,
+ eventRingEvent AlertType,
+ eventPower1FailureEvent AlertType,
+ eventPower2FailureEvent AlertType,
+ eventFaultRelayEvent AlertType,
+ eventTimeSynchronizeEvent AlertType,
+ eventSFPEvent AlertType,
+ eventDI1ChangeEvent AlertType,
+ eventDI2ChangeEvent AlertType,
+ eventLoopDetectionEvent AlertType,
+}
+
+eventSystemEventIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of events."
+ ::= { systemEventEntry 1 }
+
+eventDeviceColdStartEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when the device
+ cold starts."
+-- DESCRIPTION "Parameter to indicate the event should be logged or should be
+-- sent as an Email alert.
+-- The value can't be log(1) or logandsmtp(3), if syslogStatus
+-- is disabled. The value can't be smtp(2) or logandsmtp(3), if
+-- eventEmailAlertStatus is disabled."
+ ::= { systemEventEntry 2 }
+
+eventDeviceWarmStartEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when the device
+ warm starts."
+ ::= { systemEventEntry 3 }
+
+eventAuthenticationFailureEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when
+ authentication failure."
+ ::= { systemEventEntry 4 }
+
+eventRingEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when ring
+ event occured."
+ ::= { systemEventEntry 5 }
+
+eventPower1FailureEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when power1
+ failure."
+ ::= { systemEventEntry 6 }
+
+eventPower2FailureEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when power2
+ failure."
+ ::= { systemEventEntry 7 }
+
+eventFaultRelayEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when a fault
+ relay is triggered."
+ ::= { systemEventEntry 8 }
+
+eventTimeSynchronizeEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when time
+ synchronizatonn failed."
+ ::= { systemEventEntry 9 }
+
+eventSFPEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when SFP
+ event occured."
+ ::= { systemEventEntry 10 }
+
+eventDI1ChangeEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when DI1
+ changed ."
+ ::= { systemEventEntry 11 }
+
+eventDI2ChangeEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when DI2
+ changed ."
+ ::= { systemEventEntry 12 }
+
+eventLoopDetectionEvent OBJECT-TYPE
+ SYNTAX AlertType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select which warning machanism to take place when loop detection
+ event occured."
+ ::= { systemEventEntry 13 }
+
+-- -----------------------------------------------------------------------------
+-- Port Event Table
+-- -----------------------------------------------------------------------------
+portEventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortEventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and controls the reactions
+ to port link up, link down, or both link up and down.
+
+ Three types of reactions will be triggered: (1)logging in the
+ switch or send logs to remote syslog servers, (2)sending an
+ email, or (3)send an snmp trap. Each type of alert is configured
+ in sysLogConfiguration, smtpConfiguration, snmpTrapServerEnable
+ and snmpTrapServerTable."
+ ::= { eventSelection 2 }
+
+portEventEntry OBJECT-TYPE
+ SYNTAX PortEventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry controlling the type of port events."
+ INDEX { eventPortNumber }
+ ::= { portEventTable 1 }
+
+PortEventEntry ::= SEQUENCE {
+ eventPortNumber Integer32,
+ eventPortEvent INTEGER
+}
+
+eventPortNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port number."
+ ::= {portEventEntry 1 }
+
+eventPortEvent OBJECT-TYPE
+ SYNTAX INTEGER {
+ linkup(1),
+ linkdown(2),
+ linkupandlinkdown(3),
+ disabled(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select the port event to react to."
+ ::= { portEventEntry 2 }
+
+
+-- -----------------------------------------------------------------------------
+-- System Log
+-- -----------------------------------------------------------------------------
+
+sysLogLocalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter to configure if the log should to be kept in the
+ device or not."
+ ::= { sysLogConfiguration 1 }
+
+sysLogRemoteStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter to configure the log should be sent to a syslog
+ server specified in sysLogServerAddr or not. When disabled
+ or sysLogServerAddr is 0, the device will not send out or
+ record any log."
+ ::= { sysLogConfiguration 2 }
+
+sysLogServerAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of syslog server."
+ ::= { sysLogConfiguration 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- Email Alert
+-- -----------------------------------------------------------------------------
+eventEmailAlertStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Parameter to enable the email alert feature, When enabled,
+ the switch will send an email to the address presented in
+ emailAlertRcptTable."
+ ::= { smtpConfiguration 1 }
+
+eventEmailAlertServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of SMTP server. It can't be modified when
+ eventEmailAlertStatus is disabled."
+ ::= { smtpConfiguration 2 }
+
+eventEmailAlertAccount OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..70))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The email account for SMTP server. It can't be modified when
+ eventEmailAlertAuthentication is disabled."
+ ::= { smtpConfiguration 3 }
+
+eventEmailAlertAuthentication OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set to (1)enabled if it needs authentication to connect to
+ the SMTP server. It can't be modified when
+ eventEmailAlertStatus is disabled."
+ ::= { smtpConfiguration 4 }
+
+eventEmailAlertUser OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..70))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The email account for SMTP server. It can't be modified when
+ eventEmailAlertAuthentication is disabled."
+ ::= { smtpConfiguration 5 }
+
+eventEmailAlertPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..36))
+ MAX-ACCESS write-only
+ STATUS current
+ DESCRIPTION "The password of email account. It can't be modified when
+ eventEmailAlertAuthentication is disabled."
+ ::= { smtpConfiguration 6 }
+
+
+-- -----------------------------------------------------------------------------
+-- emailAlertReptTable
+-- -----------------------------------------------------------------------------
+
+emailAlertRcptTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EmailAlertRcptEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table configuring recipient email addresses."
+ ::= { smtpConfiguration 7 }
+
+emailAlertRcptEntry OBJECT-TYPE
+ SYNTAX EmailAlertRcptEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing recipient email address."
+ INDEX { eventEmailAlertRcptIndex }
+ ::= { emailAlertRcptTable 1 }
+
+EmailAlertRcptEntry ::= SEQUENCE {
+ eventEmailAlertRcptIndex Integer32,
+ eventEmailAlertRcptEmailAddr DisplayString
+}
+
+eventEmailAlertRcptIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of recipient Email address."
+ ::= { emailAlertRcptEntry 1 }
+
+eventEmailAlertRcptEmailAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..48))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "A recipient email address."
+ ::= { emailAlertRcptEntry 2 }
+
+-- -----------------------------------------------------------------------------
+-- Hardware Status Table
+-- -----------------------------------------------------------------------------
+
+hardwareStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HardwareStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatus 1 }
+
+hardwareStatusEntry OBJECT-TYPE
+ SYNTAX HardwareStatusEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ INDEX { ledHardwareStatusIndex }
+ ::= { hardwareStatusTable 1 }
+
+HardwareStatusEntry ::= SEQUENCE {
+ ledHardwareStatusIndex Integer32,
+ ledPower1Status INTEGER,
+ ledPower2Status INTEGER,
+ ledDO1Status INTEGER,
+ ledDO2Status INTEGER,
+ ledDI1Status INTEGER,
+ ledDI2Status INTEGER,
+ ledRMStatus INTEGER
+}
+
+ledHardwareStatusIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of leds."
+ ::= { hardwareStatusEntry 1 }
+
+ledPower1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 2 }
+
+ledPower2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 3 }
+
+ledDO1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 4 }
+
+ledDO2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 5 }
+
+ledDI1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 6 }
+
+ledDI2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 7 }
+
+ledRMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION ""
+ ::= { hardwareStatusEntry 8 }
+
+-- -----------------------------------------------------------------------------
+-- Monitor and Diag
+-- -----------------------------------------------------------------------------
+macAddressTable OBJECT IDENTIFIER ::= { monitorandDiag 1 }
+portStatistic OBJECT IDENTIFIER ::= { monitorandDiag 2 }
+portmirroring OBJECT IDENTIFIER ::= { monitorandDiag 3 }
+eventLog OBJECT IDENTIFIER ::= { monitorandDiag 4 }
+
+-- -----------------------------------------------------------------------------
+-- macAddressTable
+-- -----------------------------------------------------------------------------
+
+macAddrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MACAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table containing information about unicast or multicast
+ MAC addresses that currently learned, configured by management
+ or IGMP snooping."
+ ::= { macAddressTable 1 }
+
+macAddrEntry OBJECT-TYPE
+ SYNTAX MACAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing inforamtion about a MAC address entry."
+ INDEX { macAddressAddr }
+ ::= { macAddrTable 1 }
+
+MACAddrEntry ::= SEQUENCE {
+ macAddressAddr MacAddress,
+ macAddressType INTEGER,
+ macAddressPortList PortList,
+ macAddressVlanId Integer32,
+ macAddressStatus INTEGER
+}
+
+macAddressAddr OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "MAC address of the entry."
+ ::= { macAddrEntry 1 }
+
+macAddressType OBJECT-TYPE
+ SYNTAX INTEGER {
+ dynamicUnicast(1),
+ staticUnicast(2),
+ managementUnicast(3),
+ dynamicMulticast(4),
+ staticMulticast(5),
+ managementMulticast(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The type of this entry.
+ dynamicUnicast(1) - unicast address that learned from source
+ address of ingress frames.
+ staticUnicast(2) - unicast address that configured by management
+ and will remain so after the next reset of the device. Upto
+ 10 static unicast entries can be configured for each port.
+ managementUnicast(3) - unicast address that configured for
+ management purpose or the MAC address of the device itself.
+ Management unicast entries are read-only.
+ dynamicMulticast(4) - dynamic multicast address that configured
+ by IGMP snooping. These entries are read-only.
+ staticMulticast(5) - multicast address that configured by
+ management and will remain so after the next reset of the
+ device.
+-- Upto 10 static multicast entries can be configured.
+ managementMulticast(6) - multicast address that configured for
+ management purpose, such as GVRP and so on. These entries
+ are read-only.
+ Management entries are read-only. Dynamic entries can be read
+ and delete. Only static entries are read-create.
+ "
+ ::= { macAddrEntry 2 }
+
+macAddressPortList OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The port list, which must be valid when creating a new entry."
+ ::= { macAddrEntry 3 }
+
+macAddressVlanId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The VLAN where the mac address learned from or configured to."
+ ::= { macAddrEntry 4 }
+
+macAddressStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "This object is used to manage to creation and deletion of
+ a static entry, and is used to indicate the status of an entry.
+
+ To Creating a static entry, select a unused value of
+ macAddressIndex and set macAddressStatus to 'createAndWait'.
+ A row will then be created with status set to 'notReady' and
+ its macAddressType, macAddressPortList and macAddressVlanId
+ left unspecified.
+
+ macAddressType, macAddressPortList and macAddressVlanId are
+ mandatory to activate an entry to the device. macAddressStatus
+ remains 'notReady' if any of these three objects are invalid.
+ macAddressStatus will be changed to 'notInService' when the
+ three objects are correctly configured. Set macAddressStatus
+ to 'active' to activate the MAC entry to the device.
+
+ Static unicast and multicast entries and dynamic unicast entries
+ are removable. To delete a MAC entry, select the macAddressIndex
+ set macAddressStatus to 'destory'. The row and the corresponding
+ MAC address configurarion will be removed from the device.
+
+ Set macAddressStatus to 'createAndGo', 'notInService', 'notReady'
+ have no effects."
+ ::= { macAddrEntry 5 }
+
+macAddrTableClear OBJECT-TYPE
+ SYNTAX INTEGER {
+ clear(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set to clear for cleaning all the dynamic MAC entries in the
+ MAC address table."
+ ::= { macAddressTable 2 }
+
+
+macAddrTableAgingTime OBJECT-TYPE
+ SYNTAX INTEGER(0..3825)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This value determines the interval that an automatic learned
+ MAC address entry remains valid in the forwarding database,
+ since its last access as a source address, before being purged.
+ The value should be times of 15 in seconds. The minimum age
+ time is 15 seconds. The maximum age time is 3825 seconds or
+ almost 64 minutes. if the value is set to 0, the aging function
+ is disabled and all learned address will remain in the database
+ forever."
+ DEFVAL { 300 }
+ ::= { macAddressTable 3 }
+
+
+-- -----------------------------------------------------------------------------
+-- portStatistic
+-- -----------------------------------------------------------------------------
+
+switchPortStatTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SwitchPortStatEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive and statistics information about each
+ switch ports."
+ ::= { portStatistic 1 }
+
+
+switchPortStatClear OBJECT-TYPE
+ SYNTAX INTEGER {
+ clear(1)
+ }
+ MAX-ACCESS write-only
+ STATUS current
+ DESCRIPTION "Set to clear(1) to clear all information in the statistics
+ table."
+ ::= { portStatistic 2 }
+
+
+switchPortStatEntry OBJECT-TYPE
+ SYNTAX SwitchPortStatEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table containing descriptive information
+ and statistics of a port."
+ INDEX { swPortStatIndex }
+ ::= { switchPortStatTable 1 }
+
+SwitchPortStatEntry ::= SEQUENCE {
+ swPortStatIndex Integer32,
+ swPortStatType INTEGER,
+ swPortStatLink INTEGER,
+ swPortStatState INTEGER,
+ swPortStatRXGoodPkt Integer32,
+ swPortStatRXBadPkt Integer32,
+ swPortStatRXAbortPkt Integer32,
+ swPortStatTXGoodPkt Integer32,
+ swPortStatTXBadPkt Integer32,
+ swPortStatPacketCollision Integer32
+}
+
+swPortStatIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of port statistic table."
+ ::= { switchPortStatEntry 1 }
+
+swPortStatType OBJECT-TYPE
+ SYNTAX INTEGER {
+ hundredBaseTX(1),
+ thousandBaseT(2),
+ hundredBaseFX(3),
+ thousandBaseSX(4),
+ thousandBaseLX(5),
+ other(6),
+ notPresent(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicates the port type."
+ ::= { switchPortStatEntry 2 }
+
+swPortStatLink OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicates the link state."
+ ::= { switchPortStatEntry 3 }
+
+swPortStatState OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicates the port state."
+ ::= { switchPortStatEntry 4 }
+
+swPortStatRXGoodPkt OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of good frames received, which is the total number
+ of recieved unicast, broadcast, multicast and pause frames."
+ ::= { switchPortStatEntry 5 }
+
+swPortStatRXBadPkt OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of bad frames received, which is the total number of
+ undersize, fragment, oversize, jabber, RXErr and FCSErr frames."
+ ::= { switchPortStatEntry 6 }
+
+swPortStatRXAbortPkt OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of abort frames when receive, which is the total
+ number of discarded and filtered frames."
+ ::= { switchPortStatEntry 7 }
+
+swPortStatTXGoodPkt OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of good frames transmitted, which is the total number
+ of transmitted unicast, broadcast, multicast and pause frames."
+ ::= { switchPortStatEntry 8 }
+
+swPortStatTXBadPkt OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of FCSErr frames when transmit."
+ ::= { switchPortStatEntry 9 }
+
+swPortStatPacketCollision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The count of collision."
+ ::= { switchPortStatEntry 10 }
+
+-- -----------------------------------------------------------------------------
+-- portmirroring
+-- -----------------------------------------------------------------------------
+
+portMirrorStatus OBJECT-TYPE
+ SYNTAX Integer32 {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "To enable or disable port mirroring.
+ Port mirroring is used to send a copy of inbound or outbound
+ network packets seen on one port to another switch port.
+ Administrators may utilized this mechanism to monitor network
+ traffic as well as the performance of a switch."
+ ::= { portmirroring 1 }
+
+portMirrorDestinationPortTX OBJECT-TYPE
+ SYNTAX Integer32(0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The TX destination port (sniffer port).
+
+ Destination port can be used to see all monitor port traffic.
+ You can connect sniffer port to a LAN analysier or netxray.
+ Set to 0 to clear the configuration. A destination port can
+ not be the same as a source port.
+
+ This object can not be modified if portMirrorStatus is
+ disable."
+ ::= { portmirroring 2 }
+
+portMirrorDestinationPortRX OBJECT-TYPE
+ SYNTAX Integer32(0..10)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The RX destination port (sniffer port).
+
+ Destination port can be used to see all monitor port traffic.
+ You can connect sniffer port to a LAN analysier or netxray.
+ Set to 0 to clear the configuration. A destination port can
+ not be the same as a source port.
+
+ This object can not be modified if portMirrorStatus is
+ disable."
+ ::= { portmirroring 3 }
+
+portMirrorSourceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortMirrorSourceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information and configuration of port
+ mirroring in this system.
+ Use this table to select monitor port for this switch."
+ ::= { portmirroring 4 }
+
+portMirrorSourceEntry OBJECT-TYPE
+ SYNTAX PortMirrorSourceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Information configuring port mirroring on each port."
+ INDEX { portMirrorPortNum }
+ ::= { portMirrorSourceTable 1 }
+
+PortMirrorSourceEntry ::= SEQUENCE {
+ portMirrorPortNum Integer32,
+ portMirrorSourcePort INTEGER
+}
+
+portMirrorPortNum OBJECT-TYPE
+ SYNTAX Integer32(1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Port number."
+ ::= { portMirrorSourceEntry 1 }
+
+portMirrorSourcePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ txOnly(1),
+ rxOnly(2),
+ rxAndTx(3),
+ disabled(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The mode of source port (monitor port).
+ (1) TX only.
+ (2) RX only.
+ (3) RX and TX.
+ (4) Source port is disabled.
+ The ports you want to monitor. All source port traffic
+ will be copied to destination port (sniffer port).
+ This object can not be modified if portMirrorStatus is
+ disable."
+ ::= { portMirrorSourceEntry 2 }
+
+-- -----------------------------------------------------------------------------
+-- eventLog
+-- -----------------------------------------------------------------------------
+eventLogClear OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "clear all event log."
+ ::= {eventLog 1 }
+
+eventLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of descriptive information about logs."
+ ::= { eventLog 2 }
+
+eventLogEntry OBJECT-TYPE
+ SYNTAX EventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table containing a log."
+ INDEX { eventLogIndex }
+ ::= { eventLogTable 1 }
+
+EventLogEntry ::= SEQUENCE {
+ eventLogIndex Integer32,
+ eventLogDescription DisplayString
+}
+
+eventLogIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Index of log."
+ ::= {eventLogEntry 1 }
+
+eventLogDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..100))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The description of a log."
+ ::= { eventLogEntry 2 }
+
+-- -----------------------------------------------------------------------------
+-- save
+-- -----------------------------------------------------------------------------
+
+saveCfgMgtAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ notActive(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Setting this object to active(1) saves current configuration.
+ Setting this object to notActive(2) has no effect. The system
+ always returns the value notActive(2) when this object is read."
+ ::= { save 1 }
+
+END