diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB')
| -rw-r--r-- | MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB | 700 |
1 files changed, 700 insertions, 0 deletions
diff --git a/MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB b/MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB new file mode 100644 index 0000000..7f49e00 --- /dev/null +++ b/MIBS/cisco/CERENT-OPTICAL-MONITOR-MIB @@ -0,0 +1,700 @@ +-- ***************************************************************** +-- CERENT-OPTICAL-MONITOR-MIB.mib +-- +-- Copyright (c) 2002 by Cisco Systems, Inc. +-- All rights reserved. +-- ***************************************************************** + + +CERENT-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN + +IMPORTS + Integer32, + MODULE-IDENTITY, + OBJECT-TYPE FROM SNMPv2-SMI + TEXTUAL-CONVENTION, + TruthValue FROM SNMPv2-TC + MODULE-COMPLIANCE, + OBJECT-GROUP FROM SNMPv2-CONF + ifIndex FROM IF-MIB + cerentModules, + cerentRequirements, + cerentGeneric FROM CERENT-GLOBAL-REGISTRY + CerentPeriod FROM CERENT-TC +; + +cerentOpticalMonitorMIB MODULE-IDENTITY + LAST-UPDATED "0211110000Z" -- 2002/Nov/11 + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO "support@Cisco.com + + Postal: + Cisco Systems + 1450 N. McDowell Blvd. + Petaluma, CA 94954 + + Tel: +1-877-323-7368" + DESCRIPTION + "This MIB module defines objects to monitor optical + characteristics and set corresponding thresholds, on the + optical interfaces in a network element. + This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB. + " + REVISION "0211110000Z" -- 2002/Nov/11 + DESCRIPTION + "The initial revision of this MIB." + ::={ cerentModules 70 } + + +-- Textual Conventions + +OpticalParameterType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This value indicates the optical parameter that is + being monitored. Valid values are - + + power (1) : Optical Power (AC + DC). + acPower (2) : Optical AC Power. + apdTemp (3) : Avalanche Photo Detector Temperature. + laserTemp (4) : Laser Temperature. + biasCurrent (5) : Laser bias current. + peltierCurrent (6) : Laser peltier current. + xcvrVoltage (7) : Transceiver voltage. + voa (8) : Variable Optical Attenuation Failure & Degrade Th. + gain (9) : Optical amplifier gain Failure & Degrade Th. + oscPower (10) : OSC Optical Power + addPower (11) : Add Optical Power + " + SYNTAX INTEGER { + power(1), + acPower(2), + apdTemp(3), + laserTemp(4), + biasCurrent(5), + peltierCurrent(6), + xcvrVoltage(7), + voa(8), + gain(9), + oscPower(10), + addPower(11) + } + + +OpticalParameterValue ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The value of the optical parameter that is being monitored. + + The range of values varies depending on the type of optical + parameter being monitored, as identified by a corresponding + object with syntax OpticalParameterType. + + when the optical parameter being monitored is 'power' or + 'acpower', the supported range is from -1000 to 1000, in + 1/10ths of dBm. + Example: Actual power of -40 dbm is represented as -400. + Actual power level of +30 dBm is represented as 300. + + When the optical parameter being monitored is 'laserTemp' or + 'apdTemp', the supported range is from -10000 to 30000, in + 1/100ths of degrees centigrade. + Example: A value of 2355 represents a temperature reading of + 23.55 degrees C. + + When the optical parameter being monitored is 'biasCurrent', + the supported range is from 0 to 1000, in 1/10ths of + percentage (%). + Example: A value of 500 represents a bias current threshold + of 50.0 %. + + When the optical parameter being monitored is 'peltierCurrent', + the supported range is from 0 to 10000, in milliamperes. + + When the optical parameter being monitored is 'xcvrVoltage', + the supported range is from 0 to 100000, in 1/10ths of + millivolts. + Example: A Value of 115 represents a transceiver voltage + reading of 11.5 millivolts. + + The distinguished value of '-1000000' indicates that the object + has not yet been initialized or does not apply. + " + SYNTAX Integer32 ( -1000000..1000000 ) + + +OpticalIfDirection ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This value indicates the direction being monitored at + the optical interface. + " + SYNTAX INTEGER { + receive(1), + transmit(2), + notApplicable(3) + } + + +-- MIB Object Definitions + +cerentOpticalMonitorMIBObjects OBJECT IDENTIFIER ::= + {cerentGeneric 30 } + +-- groups in this MIB module + +cerentOpticalMonGroup OBJECT IDENTIFIER ::= + {cerentOpticalMonitorMIBObjects 1 } + +cerentOpticalPMGroup OBJECT IDENTIFIER ::= + {cerentOpticalMonitorMIBObjects 2 } + +-- cOpticalMonTable + +cOpticalMonTable OBJECT-TYPE + SYNTAX SEQUENCE OF COpticalMonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides objects to monitor optical + parameters in a network element. It also provides + objects for setting high and low threshold levels, with + configurable severities, on these monitored parameters." + ::={ cerentOpticalMonGroup 1 } + +cOpticalMonEntry OBJECT-TYPE + SYNTAX COpticalMonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the cOpticalMonTable provides objects to + monitor an optical parameter and set threshold levels + on that parameter, at an optical interface. + + Note that the set of monitored optical parameters may vary + based on interface type and direction. + + Examples of interfaces that can have an entry in this table + include optical transceivers optical amplifiers, + and optical attenuators." + INDEX { ifIndex, cOpticalMonDirection, + cOpticalMonParameterType } + ::={ cOpticalMonTable 1 } + + +COpticalMonEntry ::= SEQUENCE { + cOpticalMonDirection OpticalIfDirection, + cOpticalMonParameterType OpticalParameterType, + cOpticalParameterValue OpticalParameterValue, + cOpticalParamHighAlarmThresh OpticalParameterValue, + cOpticalParamHighWarning15MinThresh OpticalParameterValue, + cOpticalParamHighWarning1DayThresh OpticalParameterValue, + cOpticalParamLowAlarmThresh OpticalParameterValue, + cOpticalParamLowWarning15MinThresh OpticalParameterValue, + cOpticalParamLowWarning1DayThresh OpticalParameterValue, + cOpticalParamLowDegradeThresh OpticalParameterValue, + cOpticalParamHighDegradeThresh OpticalParameterValue +} + +cOpticalMonDirection OBJECT-TYPE + SYNTAX OpticalIfDirection + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the cOpticalMonTable + and indicates the direction monitored for the + optical interface, in this entry." + ::={ cOpticalMonEntry 1 } + + +cOpticalMonParameterType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the cOpticalMonTable + and specifies the optical parameter that is being monitored, + in this entry." + ::={ cOpticalMonEntry 2 } + +cOpticalParameterValue OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the value measured for the particular + optical parameter specified by the cOpticalMonParameterType + object." + ::={ cOpticalMonEntry 3 } + +cOpticalParamHighAlarmThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a high alarm threshold on the + optical parameter being monitored. + + If the measured value of the parameter,is greater than the + value configured in this object, an alarm will be raised. + + When the cOpticalMonParameterType object is set to 'power' + for the receive direction at a transceiver, this object + specifies the receiver saturation level." + ::={ cOpticalMonEntry 4 } + + +cOpticalParamHighWarning15MinThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a high warning 15 minute threshold + on the optical parameter being monitored. + + If the measured value of the parameter,is greater than the + value configured in this object, an alarm may be raised." + ::={ cOpticalMonEntry 5 } + +cOpticalParamHighWarning1DayThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a high warning 1 day threshold on + the optical parameter being monitored. + + If the measured value of the parameter,is greater than the + value configured in this object, an alarm may be raised." + ::={ cOpticalMonEntry 6 } + +cOpticalParamLowAlarmThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a low alarm threshold on the + optical parameter being monitored. + + If the measured value of the parameter,goes lower than the + value configured in this object, an alarm will be raised. + + When the cOpticalMonParameterType object is set to 'power' + for the receive direction and when the interface supports + alarms based on loss of light, this object specifies the + optical power threshold for declaring loss of light. Also, + when optical amplifiers are present in the network, in the + receive direction, this value may need to be configured, + since the noise floor may be higher than the minimum + sensitivity of the receiver." + ::={ cOpticalMonEntry 7 } + +cOpticalParamLowWarning15MinThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a low warning 15 minute threshold + on the optical parameter being monitored. + + If the measured value of the parameter,goes lower than the + value configured in this object, an alarm will be raised." + ::={ cOpticalMonEntry 8 } + +cOpticalParamLowWarning1DayThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a low warning 1 day threshold + on the optical parameter being monitored. + + If the measured value of the parameter,goes lower than the + value configured in this object, an alarm will be raised." + ::={ cOpticalMonEntry 9 } + +cOpticalParamLowDegradeThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a low degrade threshold + on the optical parameter being monitored. + + If the measured value of the parameter,goes lower than the + value configured in this object, a degrade alarm will be raised." + ::={ cOpticalMonEntry 10 } + +cOpticalParamHighDegradeThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set a high degrade threshold + on the optical parameter being monitored. + + If the measured value of the parameter,goes lower than the + value configured in this object, a degrade alarm will be raised." + ::={ cOpticalMonEntry 11 } + + +-- cOpticalPMCurrent Table + +cOpticalPMCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF COpticalPMCurrentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table stores performance monitoring data for the + various optical parameters, collected over the current + interval." + ::={ cerentOpticalPMGroup 1 } + +cOpticalPMCurrentEntry OBJECT-TYPE + SYNTAX COpticalPMCurrentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the cOpticalPMCurrentTable. It contains + performance monitoring data for an optical parameter, + collected over the current interval. + + Note that the set of monitored optical parameters may vary + based on interface type and direction. + + Examples of interfaces that can have an entry in this table + include optical transceivers, optical amplifiers, and optical + attenuators." + INDEX { ifIndex, + cOpticalPMCurrentDirection, + cOpticalPMCurrentParamType, + cOpticalPMCurrentPeriod} + ::={ cOpticalPMCurrentTable 1 } + +COpticalPMCurrentEntry ::= SEQUENCE { + cOpticalPMCurrentDirection OpticalIfDirection, + cOpticalPMCurrentParamType OpticalParameterType, + cOpticalPMCurrentPeriod CerentPeriod, + cOpticalPMCurrentMaxParam OpticalParameterValue, + cOpticalPMCurrentMinParam OpticalParameterValue, + cOpticalPMCurrentMeanParam OpticalParameterValue +} + + +cOpticalPMCurrentDirection OBJECT-TYPE + SYNTAX OpticalIfDirection + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the cOpticalPMCurrentTable + and indicates the direction monitored + for the optical interface, in this entry." + ::={ cOpticalPMCurrentEntry 1 } + +cOpticalPMCurrentParamType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the + cOpticalPMCurrentTable and specifies the optical parameter + that is being monitored, in this entry." + ::={ cOpticalPMCurrentEntry 2 } + +cOpticalPMCurrentPeriod OBJECT-TYPE + SYNTAX CerentPeriod + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the + cOpticalPMCurrentTable and indicates whether the + optical parameter values given in this entry, are collected + over a period of 15 minutes or 24 hours." + ::={ cOpticalPMCurrentEntry 3 } + +cOpticalPMCurrentMaxParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the maximum value measured for the optical + parameter, in the current 15 minute or 24 hour interval." + ::={ cOpticalPMCurrentEntry 4 } + +cOpticalPMCurrentMinParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the minimum value measured for the optical + parameter, in the current 15 minute or 24 hour interval." + ::={ cOpticalPMCurrentEntry 5 } + +cOpticalPMCurrentMeanParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the average value of the measured optical + parameter, in the current 15 minute or 24 hour interval." + ::={ cOpticalPMCurrentEntry 6 } + +-- cOpticalPMInterval Table + +cOpticalPMIntervalTable OBJECT-TYPE + SYNTAX SEQUENCE OF COpticalPMIntervalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table stores performance monitoring data for the + various optical parameters, collected over current and + previous intervals. + + This table can have entries for up to 96 complete 15 minute + intervals." + ::={ cerentOpticalPMGroup 2 } + +cOpticalPMIntervalEntry OBJECT-TYPE + SYNTAX COpticalPMIntervalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the cOpticalPMIntervalTable. It contains + performance monitoring data for an optical parameter, + collected over current and previous intervals. + + Note that the set of monitored optical parameters may vary + based on interface type and direction. + + Examples of interfaces that can have an entry in this table + include optical transceivers, optical amplifiers, and optical + attenuators." + INDEX { ifIndex, + cOpticalPMIntervalDirection, + cOpticalPMIntervalParamType, + cOpticalPMIntervalPeriod, + cOpticalPMIntervalNumber} + ::={ cOpticalPMIntervalTable 1 } + +COpticalPMIntervalEntry ::= SEQUENCE { + cOpticalPMIntervalDirection OpticalIfDirection, + cOpticalPMIntervalParamType OpticalParameterType, + cOpticalPMIntervalPeriod CerentPeriod, + cOpticalPMIntervalNumber Integer32, + cOpticalPMIntervalMaxParam OpticalParameterValue, + cOpticalPMIntervalMinParam OpticalParameterValue, + cOpticalPMIntervalMeanParam OpticalParameterValue, + cOpticalPMIntervalValidData TruthValue +} + + +cOpticalPMIntervalDirection OBJECT-TYPE + SYNTAX OpticalIfDirection + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the cOpticalPMIntervalTable + and indicates the direction monitored + for the optical interface, in this entry." + ::={ cOpticalPMIntervalEntry 1 } + +cOpticalPMIntervalParamType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the + cOpticalPMIntervalTable and specifies the optical parameter + that is being monitored, in this entry." + ::={ cOpticalPMIntervalEntry 2 } + +cOpticalPMIntervalPeriod OBJECT-TYPE + SYNTAX CerentPeriod + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the + cOpticalPMIntervalTable and indicates whether the + optical parameter values given in this entry, are collected + over a period of 15 minutes or 24 hours." + ::={ cOpticalPMIntervalEntry 3 } + +cOpticalPMIntervalNumber OBJECT-TYPE + SYNTAX Integer32 (1..96) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is an index into the cOpticalPMIntervalTable. + It is a number between 1 and 96, which identifies the + interval for which the set of optical parameter values is + available. The interval identified by 1 is the most recent + 15 minute or 24 hour interval, and the interval + identified by N is the interval immediately preceding the one + identified by N-1." + ::={ cOpticalPMIntervalEntry 4 } + +cOpticalPMIntervalMaxParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the maximum value measured for the optical + parameter, in a particular 15 minute or 24 hour interval." + ::={ cOpticalPMIntervalEntry 5 } + +cOpticalPMIntervalMinParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the minimum value measured for the optical + parameter, in a particular 15 minute or 24 hour interval." + ::={ cOpticalPMIntervalEntry 6 } + +cOpticalPMIntervalMeanParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the average value of the measured optical + parameter, in a particular 15 minute or 24 hour interval." + ::={ cOpticalPMIntervalEntry 7 } + +cOpticalPMIntervalValidData OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates if the data for this + interval is valid." + ::= { cOpticalPMIntervalEntry 8 } + + +-- MIB Conformance Statements + +cerentOpticalMonitorMIBConformance OBJECT IDENTIFIER ::= + { cerentRequirements 20 } + +cerentOpticalMonitorMIBCompliances OBJECT IDENTIFIER ::= + { cerentOpticalMonitorMIBConformance 1 } + +cerentOpticalMonitorMIBGroups OBJECT IDENTIFIER ::= + { cerentOpticalMonitorMIBConformance 2 } + + +cerentOpticalMonitorMIBCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for network elements that + monitor optical characteristics and set thresholds on the + optical interfaces in a network element." + MODULE -- this module + MANDATORY-GROUPS { cerentOpticalMIBMonGroup } + + GROUP cerentOpticalMIBThresholdGroup + DESCRIPTION + "This group is required for network elements that support + thresholds on optical parameters." + + GROUP cerentOpticalMIBPMGroup + DESCRIPTION + "This group is required for network elements that + support collection of optical performance monitoring + data for 15 minute or 24 hour intervals." + + OBJECT cOpticalParamHighAlarmThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cOpticalParamHighWarning15MinThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cOpticalParamHighWarning1DayThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cOpticalParamLowAlarmThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cOpticalParamLowWarning15MinThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cOpticalParamLowWarning1DayThresh + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + ::={ cerentOpticalMonitorMIBCompliances 1 } + +-- Units of Conformance + +cerentOpticalMIBMonGroup OBJECT-GROUP + OBJECTS { + cOpticalParameterValue + } + STATUS current + DESCRIPTION + "A mandatory object that provides monitoring of optical + characteristics." + ::={ cerentOpticalMonitorMIBGroups 1 } + +cerentOpticalMIBThresholdGroup OBJECT-GROUP + OBJECTS { + cOpticalParamHighAlarmThresh, + cOpticalParamHighWarning15MinThresh, + cOpticalParamHighWarning1DayThresh, + cOpticalParamLowAlarmThresh, + cOpticalParamLowWarning15MinThresh, + cOpticalParamLowWarning1DayThresh + } + STATUS current + DESCRIPTION + "A collection of objects that support thresholds on optical + parameters and provide status information when the thresholds + are exceeded or cleared." + ::={ cerentOpticalMonitorMIBGroups 2 } + +cerentOpticalMIBPMGroup OBJECT-GROUP + OBJECTS { + cOpticalPMCurrentMaxParam, + cOpticalPMCurrentMinParam, + cOpticalPMCurrentMeanParam, + cOpticalPMIntervalMaxParam, + cOpticalPMIntervalMinParam, + cOpticalPMIntervalMeanParam, + cOpticalPMIntervalValidData + } + STATUS current + DESCRIPTION + "A collection of objects that provide optical performance + monitoring data for 15 minute and 24 hour intervals." + ::={ cerentOpticalMonitorMIBGroups 3 } + +cerentOpticalDwdmNetworkMIBThresholdGroup OBJECT-GROUP + OBJECTS { + cOpticalParamHighAlarmThresh, + cOpticalParamHighWarning15MinThresh, + cOpticalParamHighWarning1DayThresh, + cOpticalParamLowAlarmThresh, + cOpticalParamLowWarning15MinThresh, + cOpticalParamLowWarning1DayThresh, + cOpticalParamLowDegradeThresh, + cOpticalParamHighDegradeThresh + } + STATUS current + DESCRIPTION + "A collection of objects that support thresholds on optical + DWDM Network parameters and provide status information when + the thresholds are exceeded or cleared." + ::={ cerentOpticalMonitorMIBGroups 4 } + +END + |