+XXX-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Gauge32,
+ Integer32,Counter32,enterprises,
+ NOTIFICATION-TYPE FROM SNMPv2-SMI
+ DisplayString FROM SNMPv2-TC;
+
+company MODULE-IDENTITY
+ LAST-UPDATED "200903050000Z"
+ ORGANIZATION "CData"
+ CONTACT-INFO "www.cdatatec.com"
+ DESCRIPTION "Media Converter NMS SNMP mib file"
+ REVISION "200903050000Z"
+ DESCRIPTION "1G MC supported"
+ ::= { enterprises 34592 }
+
+ipProduct OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "IP product line"
+ ::= {company 1}
+
+height2HU OBJECT IDENTIFIER ::= {ipProduct 1}
+
+systemMIB OBJECT IDENTIFIER ::= {height2HU 1}
+
+alarmMIB OBJECT IDENTIFIER ::= {height2HU 2}
+
+-- [ShelfInfo] --
+shelfNum OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The number of shelf in current system"
+ ::= { systemMIB 1 }
+
+shelfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ShelfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Shelf table"
+ ::= { systemMIB 2 }
+
+shelfEntry OBJECT-TYPE
+ SYNTAX ShelfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Shelf entry definition"
+ INDEX { shelfName }
+ ::= { shelfTable 1 }
+
+ShelfEntry ::= SEQUENCE {
+ shelfName INTEGER,
+ psuA INTEGER,
+ psuB INTEGER,
+ volA INTEGER,
+ volB INTEGER,
+ fan INTEGER,
+ temperature INTEGER,
+ coCardNum INTEGER,
+ rmtCardNum INTEGER
+ }
+
+shelfName OBJECT-TYPE
+ SYNTAX INTEGER {master(1),slave_1(2),slave_2(3),slave_3(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shelf name"
+ ::= { shelfEntry 1 }
+
+psuA OBJECT-TYPE
+ SYNTAX INTEGER {on(1),off(2),nc(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The status fan A of current shelf"
+ ::= { shelfEntry 2 }
+
+psuB OBJECT-TYPE
+ SYNTAX INTEGER {on(1),off(2),nc(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The status psu B of current shelf"
+ ::= { shelfEntry 3 }
+
+volA OBJECT-TYPE
+ SYNTAX INTEGER {normal(1),abnormal(2),nc(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The voltage status of psuA of current shelf"
+ ::= { shelfEntry 4 }
+
+volB OBJECT-TYPE
+ SYNTAX INTEGER {normal(1),abnormal(2),nc(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The voltage status of psuB of current shelf"
+ ::= { shelfEntry 5 }
+
+fan OBJECT-TYPE
+ SYNTAX INTEGER {on(1),off(2),nc(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The status fan A of current shelf"
+ ::= { shelfEntry 6 }
+
+temperature OBJECT-TYPE
+ SYNTAX INTEGER
+ UNITS " °C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The temperature status of current shelf"
+ ::= { shelfEntry 7 }
+
+coCardNum OBJECT-TYPE
+ SYNTAX INTEGER (0..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The number of center card inserting of current shelf"
+ ::= { shelfEntry 8 }
+
+rmtCardNum OBJECT-TYPE
+ SYNTAX INTEGER (0..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The number of remote card inserting of current shelf"
+ ::= { shelfEntry 9 }
+
+-- [Slot Objects] --
+
+slotObjects OBJECT IDENTIFIER ::= {systemMIB 3}
+
+slotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Sparse table containing one entry for each slot in exist
+ chassis in the system, indexed by shelfIdx and slotIdx."
+ ::= { slotObjects 1 }
+
+slotEntry OBJECT-TYPE
+ SYNTAX SlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "in this table ,user can find the converter module's type inserted
+ in the system's slot.then you can get the detail information about
+ the specified type in the cardObjects table"
+ INDEX { shelfIdx, slotIdx }
+ ::= { slotTable 1 }
+
+SlotEntry ::= SEQUENCE {
+ shelfIdx INTEGER,
+ slotIdx INTEGER,
+ coCardType INTEGER,
+ coCardDesc DisplayString,
+ rmtCardType INTEGER,
+ rmtCardDesc DisplayString
+ }
+
+shelfIdx OBJECT-TYPE
+ SYNTAX INTEGER {master(1),slave_1(2),slave_2(3),slave_3(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Chassis index - 1 = master management module,
+ 2-4 = slave management module"
+ ::= { slotEntry 1 }
+
+slotIdx OBJECT-TYPE
+ SYNTAX INTEGER {slot01(1),slot02(2),slot03(3),slot04(4),
+ slot05(5),slot06(6),slot07(7),slot08(8),
+ slot09(9),slot10(10),slot11(11),slot12(12),
+ slot13(13),slot14(14),slot15(15),slot16(16), slot17(17)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "chassis's slot,whitch is a index in this table"
+ ::= { slotEntry 2 }
+
+coCardType OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),ip113s(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),fr600f-mm(100),fr600f-ms(101),not-support(102)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "local card's type inserted in the chassis"
+ ::= { slotEntry 3 }
+
+coCardDesc OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "local card's description"
+ ::= { slotEntry 4 }
+
+rmtCardType OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),ip113sr(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),fr600f-mm(100),fr600f-ms(101),not-support(102)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "remote card's type connect with the local converter"
+ ::= { slotEntry 5 }
+
+rmtCardDesc OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "remote card's description"
+ ::= { slotEntry 6 }
+
+-- [Card Objects] --
+cardObjects OBJECT IDENTIFIER ::= {systemMIB 4}
+
+-- --[NMU Objects] --
+nmuObjects OBJECT IDENTIFIER ::= {cardObjects 1}
+nmuConfig OBJECT IDENTIFIER ::= {nmuObjects 1}
+
+nmuType OBJECT-TYPE
+ SYNTAX INTEGER {fr600f-mm(100),fr600f-ms(101),not-support(102)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The type of NMU (network management unit)"
+ ::= { nmuConfig 1 }
+
+ipaddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The ethernet IP address of NMU (network management unit)"
+ ::= { nmuConfig 2 }
+
+subnet OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The etherent mask address of NMU (network management unit)"
+ ::= { nmuConfig 3 }
+
+gateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The ethernet gateway address of NMU (network management unit)"
+ ::= { nmuConfig 4 }
+
+sysContact OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Mirror of the system.sysContact.0"
+ ::= { nmuConfig 5 }
+
+sysName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Mirror of the system.sysName.0"
+ ::= { nmuConfig 6 }
+
+sysLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Mirror of the system.sysLocation.0"
+ ::= { nmuConfig 7 }
+
+trapHost1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The first host's IP address used to receive trap messages,
+ when set 0 it simply delete this entry. This applies to the trap host 2~4 below as well."
+ ::= { nmuConfig 8 }
+
+trapHost2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The second host's IP address used to receive trap messages"
+ ::= { nmuConfig 9 }
+
+trapHost3 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The third host's IP address used to receive trap messages"
+ ::= { nmuConfig 10 }
+
+trapHost4 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The fourth host's IP address used to receive trap messages"
+ ::= { nmuConfig 11 }
+
+-- --[MC Configuration table] --
+mcCmObjects OBJECT IDENTIFIER ::= {cardObjects 2}
+
+mcCmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF McCmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC Configuration table"
+ ::= { mcCmObjects 1 }
+
+mcCmEntry OBJECT-TYPE
+ SYNTAX McCmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC Configuration entry definition"
+ INDEX { mcShelfIdx, mcCardIdx }
+ ::= { mcCmTable 1 }
+
+McCmEntry ::= SEQUENCE {
+ mcShelfIdx INTEGER,
+ mcCardIdx INTEGER,
+
+ mcType INTEGER,
+ mcTransceiverMode INTEGER,
+ mcTransceiverDist INTEGER,
+ mcPortState INTEGER,
+ mcTransmitMode INTEGER,
+ mcCurWorkMode INTEGER,
+ mcCfgWorkMode INTEGER,
+ mcLFPCfg INTEGER,
+ mcUpStream Gauge32,
+ mcDownStream Gauge32,
+ mcTxlink INTEGER,
+ mcFxlink INTEGER,
+ mcHWLFP INTEGER,
+ mcHWTransmitMode INTEGER,
+ mcHWWorkMode INTEGER,
+ mcHWRmtCtrlMode INTEGER,
+ mcNtwSfpExist INTEGER, -- for 1G E2O or O2O card
+ mcAccSfpExist INTEGER, -- for 1G O2O card only
+ mcUtility INTEGER,
+
+ mcRmtDetect INTEGER,
+ mcRmtType INTEGER,
+ mcRmtTransmitMode INTEGER,
+ mcRmtCurWorkMode INTEGER,
+ mcRmtCfgWorkMode INTEGER,
+ mcRmtLFP INTEGER,
+ mcRmtTxlink INTEGER,
+ mcRmtHWLFP INTEGER,
+ mcRmtHWTransmitMode INTEGER,
+ mcRmtHWWorkMode INTEGER,
+ mcRmtLoopback INTEGER,
+ mcRmtPwrDown INTEGER,
+ mcRmtAccSfpExist INTEGER, -- for 1G O2O card only. NtwSfp is always exist when remore detected.
+ mcRmtUtility INTEGER
+ }
+
+
+mcShelfIdx OBJECT-TYPE
+ SYNTAX INTEGER {master(1),slave1(2),slave2(3),slave3(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shelf index"
+ ::= { mcCmEntry 1 }
+
+mcCardIdx OBJECT-TYPE
+ SYNTAX INTEGER {card01(1),card02(2),card03(3),card04(4),
+ card05(5),card06(6),card07(7),card08(8),
+ card09(9),card10(10),card11(11),card12(12),
+ card13(13),card14(14),card15(15),card16(16)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Card index"
+ ::= { mcCmEntry 2 }
+
+mcType OBJECT-TYPE
+ SYNTAX INTEGER {ip113s(1),ip113f(2),mc_1g_e2o(3),mc_1g_o2o(4),not-support(5)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's type"
+ ::= { mcCmEntry 3 }
+
+mcTransceiverMode OBJECT-TYPE
+ SYNTAX INTEGER {bidi(1),duplex_fiber(2),sfp(3),not-support(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's optical transceiver mode.
+ 100M card support bidi/duplex_fiber; 1G card support bidi/duplex_fiber/sfp.
+ Once sfp is given, the following mcTransceiverDist should be ignored."
+ ::= { mcCmEntry 4 }
+
+mcTransceiverDist OBJECT-TYPE
+ SYNTAX INTEGER (1..120)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's optical transceiver distance,
+ 1 means 550m for duplex_fiber mode in case of 1G card,
+ otherwise it represents the real distance (unit of km)."
+ ::= { mcCmEntry 5 }
+
+mcPortState OBJECT-TYPE
+ SYNTAX INTEGER {locked(1),unlocked(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Center card's port status, locked or unlocked"
+ ::= { mcCmEntry 6 }
+
+mcTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {cut-through(1),store-forward(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Center card's transmmit mode"
+ ::= { mcCmEntry 7 }
+
+mcCurWorkMode OBJECT-TYPE
+ SYNTAX INTEGER { -- mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Center card's current work mode"
+ ::= { mcCmEntry 8 }
+
+mcCfgWorkMode OBJECT-TYPE
+ SYNTAX INTEGER {mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Center card's configurable work mode"
+ ::= { mcCmEntry 9 }
+
+mcLFPCfg OBJECT-TYPE
+ SYNTAX INTEGER {enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remote fault detect function, valid only on center MC card"
+ ::= { mcCmEntry 10 }
+
+mcUpStream OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Center card's up stream of MC"
+ ::= { mcCmEntry 11}
+
+mcDownStream OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Center card's down stream of MC"
+ ::= { mcCmEntry 12 }
+
+mcTxlink OBJECT-TYPE
+ SYNTAX INTEGER {up(1),down(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's electrical port's link status"
+ ::= { mcCmEntry 13 }
+
+mcFxlink OBJECT-TYPE
+ SYNTAX INTEGER {up(1),down(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's optical port's link status"
+ ::= { mcCmEntry 14 }
+
+mcHWLFP OBJECT-TYPE
+ SYNTAX INTEGER {enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's HW LFP, not applicable for 1G card"
+ ::= { mcCmEntry 15 }
+
+mcHWTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {cut-through(1),store-forward(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's HW transmit mode, not applicable for 1G card"
+ ::= { mcCmEntry 16 }
+
+mcHWWorkMode OBJECT-TYPE
+ SYNTAX INTEGER {mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's HW work mode, not applicable for 1G card"
+ ::= { mcCmEntry 17 }
+
+mcHWRmtCtrlMode OBJECT-TYPE
+ SYNTAX INTEGER {enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center card's HW remote control mode (only valid for local card).
+ the disable mode indicates that all SET operations must be prohibited"
+ ::= { mcCmEntry 18 }
+
+mcNtwSfpExist OBJECT-TYPE
+ SYNTAX INTEGER {inserted(1),removed(2),na(3),not-support(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center 1G card's Network SFP indication"
+ ::= { mcCmEntry 19 }
+
+mcAccSfpExist OBJECT-TYPE
+ SYNTAX INTEGER {inserted(1),removed(2),na(3),not-support(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Center 1G card's Access SFP indication, applicable only for O2O type"
+ ::= { mcCmEntry 20 }
+
+mcUtility OBJECT-TYPE
+ SYNTAX INTEGER {idle(1),reset(2),default(3),set2hw(4),not-support(5)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "reset, default to factory, set to HW word, etc..."
+ ::= { mcCmEntry 21 }
+
+mcRmtDetect OBJECT-TYPE
+ SYNTAX INTEGER {no_remote(0),yes(1),not-support(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "An identifier to indicate if there is a remote MC currently connecting to system or not"
+ ::= { mcCmEntry 22 }
+
+mcRmtType OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),ip113sr(1),ip113f(2),mc_1g_e2or(3),mc_1g_o2or(4),not-support(5)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's type"
+ ::= { mcCmEntry 23 }
+
+mcRmtTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),cut-through(1),store-forward(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remote card's transmmit mode"
+ ::= { mcCmEntry 24 }
+
+mcRmtCurWorkMode OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),
+ -- mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Remote card's current work mode"
+ ::= { mcCmEntry 25 }
+
+mcRmtCfgWorkMode OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),
+ mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION "Remote card's configurable work mode"
+ ::= { mcCmEntry 26 }
+
+mcRmtLFP OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remote card's LFP lamp state"
+ ::= { mcCmEntry 27 }
+
+mcRmtTxlink OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),up(1),down(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's electrial port status"
+ ::= { mcCmEntry 28 }
+
+mcRmtHWLFP OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's HW LFP, not applicable for 1G card"
+ ::= { mcCmEntry 29 }
+
+mcRmtHWTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),cut-through(1),store-forward(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's HW transmit mode, not applicable for 1G card"
+ ::= { mcCmEntry 30 }
+
+mcRmtHWWorkMode OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),
+ mAuto(1),
+ m100-full(2),
+ m100-half(3),
+ m10-full(4),
+ m10-half(5),
+ m1G-full(6),
+ not-support(7)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's HW work mode, not applicable for 1G card"
+ ::= { mcCmEntry 31 }
+
+mcRmtLoopback OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),enable(1),disable(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remote card's HW Loopback state"
+ ::= { mcCmEntry 32 }
+
+mcRmtPwrDown OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),powerdown(1),normal(2),not-support(3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote card's power down state"
+ ::= { mcCmEntry 33 }
+
+mcRmtAccSfpExist OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),inserted(1),removed(2),na(3),support(4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote 1G card's Access SFP indication, applicable only for O2O type"
+ ::= { mcCmEntry 34 }
+
+mcRmtUtility OBJECT-TYPE
+ SYNTAX INTEGER {no_card(0),idle(1),reset(2),default(3),set2hw(4),not-support(5)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Rmote cards's reset, default to factory, set to HW word, etc..."
+ ::= { mcCmEntry 35 }
+
+-- --[MC 1G card Specific CM table] --
+mcCm1gSpecificObjects OBJECT IDENTIFIER ::= {mcCmObjects 2}
+
+-- -- --[MC 1G card IP table] --
+mcCm1gIpObjects OBJECT IDENTIFIER ::= {mcCm1gSpecificObjects 1}
+
+mcCm1gIpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF McCm1gIpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC 1G Ip address table"
+ ::= { mcCm1gIpObjects 1 }
+
+mcCm1gIpEntry OBJECT-TYPE
+ SYNTAX McCm1gIpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC 1G Ip address entry definition"
+ INDEX { mcShelfIdx,mcCardIdx,mcLoOrRmtFg }
+ ::= { mcCm1gIpTable 1 }
+
+McCm1gIpEntry ::= SEQUENCE {
+ mcLoOrRmtFg INTEGER,
+ mcIpAddr IpAddress
+ }
+
+mcLoOrRmtFg OBJECT-TYPE
+ SYNTAX INTEGER {local(1),remote(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "location index, local or remote"
+ ::= { mcCm1gIpEntry 1 }
+
+mcIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Ip address of the node"
+ ::= { mcCm1gIpEntry 2 }
+
+-- -- --[MC 1G card SFP table] --
+mcCm1gSfpObjects OBJECT IDENTIFIER ::= {mcCm1gSpecificObjects 2}
+
+mcCm1gSfpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF McCm1gSfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC 1G SFP table"
+ ::= { mcCm1gSfpObjects 1 }
+
+mcCm1gSfpEntry OBJECT-TYPE
+ SYNTAX McCm1gSfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC 1G SFP entry definition"
+ INDEX { mcShelfIdx,mcCardIdx,mcLoOrRmtFg }
+ ::= { mcCm1gSfpTable 1 }
+
+McCm1gSfpEntry ::= SEQUENCE {
+ getSfpCmd INTEGER,
+ sfpCompliance INTEGER,
+ sfpConnector INTEGER,
+ sfpTransCode INTEGER,
+ sfpSmLength INTEGER,
+ sfpMmLength INTEGER,
+ sfpCopperLength INTEGER,
+ sfpBrSpeed INTEGER,
+ sfpWavelength INTEGER,
+ sfpTemperature INTEGER,
+ sfpTranPower INTEGER,
+ sfpRecvPower INTEGER,
+ sfpVoltage INTEGER
+ }
+
+getSfpCmd OBJECT-TYPE
+ SYNTAX INTEGER {na(0),local(1),remote(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This command will get the updated sfp information.
+ Please send this command prior to getting the following params,
+ otherwise the history sfp information will be sent back."
+ ::= { mcCm1gSfpEntry 1 }
+
+sfpCompliance OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP compliance (one byte)
+ if 0 then the attributs of sfpTemperature/sfpTranPower/sfpRecvPower
+ should be ignored"
+ ::= { mcCm1gSfpEntry 2 }
+
+sfpConnector OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP connector type (one byte)
+ 0x01: SC
+ 0x07: LC
+ 0x22: RJ45
+ others: unsupported"
+ ::= { mcCm1gSfpEntry 3 }
+
+sfpTransCode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP transceiver code (one byte)
+ bit0: SingleMode
+ bit2: MultiMode
+ bit3: MultiMode
+ others: unsupported"
+ ::= { mcCm1gSfpEntry 4 }
+
+sfpSmLength OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP link length for SingleMode, units of km. (one byte)
+ applicable only when sfpTransCode is SingleMode"
+ ::= { mcCm1gSfpEntry 5 }
+
+sfpMmLength OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP link length for MultiMode, units of 10m (one byte)
+ applicable only when sfpTransCode is MultiMode"
+ ::= { mcCm1gSfpEntry 6 }
+
+sfpCopperLength OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP link length for Copper, units of m (one byte)
+ applicable only when sfpConnector is RJ45"
+ ::= { mcCm1gSfpEntry 7 }
+
+sfpBrSpeed OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP nominal signalling rate, units of 100Mbit/s (one byte)"
+ ::= { mcCm1gSfpEntry 8 }
+
+sfpWavelength OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP laser wavelength (one word)"
+ ::= { mcCm1gSfpEntry 9 }
+
+sfpTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP temperature (one type, signed)"
+ ::= { mcCm1gSfpEntry 10 }
+
+sfpTranPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP tx power (one type, signed)"
+ ::= { mcCm1gSfpEntry 11 }
+
+sfpRecvPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP rx power (one type, signed)"
+ ::= { mcCm1gSfpEntry 12 }
+
+sfpVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP voltage, units of 0.1mV (one word)"
+ ::= { mcCm1gSfpEntry 13 }
+
+-- --[MC Performance table] --
+mcPmObjects OBJECT IDENTIFIER ::= {cardObjects 3}
+
+mcPmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF McPmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC Performance table"
+ ::= { mcPmObjects 1 }
+
+mcPmEntry OBJECT-TYPE
+ SYNTAX McPmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "MC Performance entry definition"
+ INDEX { mcShelfIdx, mcCardIdx }
+ ::= { mcPmTable 1 }
+
+McPmEntry ::= SEQUENCE {
+ mcRxByteHi Counter32,
+ mcRxByteLo Counter32,
+ mcTxByteHi Counter32,
+ mcTxByteLo Counter32,
+ mcPmRest INTEGER
+ }
+
+mcRxByteHi OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total number of reveive bytes (high)"
+ ::= { mcPmEntry 1 }
+
+mcRxByteLo OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total number of reveive bytes (low)"
+ ::= { mcPmEntry 2 }
+
+mcTxByteHi OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total number of transmit bytes (high)"
+ ::= { mcPmEntry 3 }
+
+mcTxByteLo OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total number of transmit bytes (low)"
+ ::= { mcPmEntry 4 }
+
+mcPmRest OBJECT-TYPE
+ SYNTAX INTEGER {idle(1), reset(2),not-support(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "reset counter"
+ ::= { mcPmEntry 5 }
+
+-- ---------------------------------------------------------------------------------------------
+-- [Trap definition] --
+
+-- --[shelf alarm] -- (1~19)
+shelf-Detected NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "A slave shelf is detected"
+ ::= { alarmMIB 1}
+
+shelf-Lost NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "A shelf is lost"
+ ::= { alarmMIB 2}
+
+shelf-psuA-On NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "PSU A is detected"
+ ::= { alarmMIB 3}
+
+shelf-psuA-Off NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "PSU A is lost"
+ ::= { alarmMIB 4}
+
+shelf-psuB-On NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "PSU B is detected"
+ ::= { alarmMIB 5}
+
+shelf-psuB-Off NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "PSU B is lost"
+ ::= { alarmMIB 6}
+
+shelf-fan-On NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "Fan A is detected"
+ ::= { alarmMIB 7}
+
+shelf-fan-Off NOTIFICATION-TYPE
+ OBJECTS { shelfIdx }
+ STATUS current
+ DESCRIPTION "Fan A is lost"
+ ::= { alarmMIB 8}
+
+-- --[card common alarm] -- (20~29)
+card-Detected NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "A card is detected"
+ ::= { alarmMIB 20}
+
+card-Lost NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "A card is lost"
+ ::= { alarmMIB 21}
+
+-- --[card specific (MC) alarm] -- (above 30)
+card-MC-Co-Tx-Up NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The tx link of mc in center side is up"
+ ::= { alarmMIB 30}
+
+card-MC-Co-Tx-Down NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The tx link of mc in center side is broken"
+ ::= { alarmMIB 31}
+
+card-MC-Co-Fx-Up NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The fx link of mc in center side is up"
+ ::= { alarmMIB 32}
+
+card-MC-Co-Fx-Down NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The fx link of mc in center side is broken"
+ ::= { alarmMIB 33}
+
+card-MC-Rmt-Tx-Up NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The tx link of mc in customer side is up"
+ ::= { alarmMIB 34}
+
+card-MC-Rmt-Tx-Down NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "The tx link of mc in customer side is broken"
+ ::= { alarmMIB 35}
+
+card-MC-Rmt-PwrDown NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Remote mc power down detected"
+ ::= { alarmMIB 36}
+
+card-MC-Co-Ntw-SFP-Inserted NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Local network port SFP inserted"
+ ::= { alarmMIB 37}
+
+card-MC-Co-Ntw-SFP-Removed NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Local network port SFP removed"
+ ::= { alarmMIB 38}
+
+card-MC-Co-Acc-SFP-Inserted NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Local access port SFP inserted"
+ ::= { alarmMIB 39}
+
+card-MC-Co-Acc-SFP-Removed NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Local access port SFP removed"
+ ::= { alarmMIB 40}
+
+card-MC-Rmt-Acc-SFP-Inserted NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Remote access port SFP inserted"
+ ::= { alarmMIB 41}
+
+card-MC-Rmt-Acc-SFP-Removed NOTIFICATION-TYPE
+ OBJECTS { shelfIdx, slotIdx }
+ STATUS current
+ DESCRIPTION "Remote access port SFP removed"
+ ::= { alarmMIB 42}
+
+END
|