diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB')
| -rw-r--r-- | MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB | 244 |
1 files changed, 244 insertions, 0 deletions
diff --git a/MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB b/MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB new file mode 100644 index 0000000..f14d87c --- /dev/null +++ b/MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB @@ -0,0 +1,244 @@ +BLUECOAT-SG-SENSOR-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, TimeStamp, TruthValue, DisplayString + FROM SNMPv2-TC + blueCoatMgmt + FROM BLUECOAT-MIB; + +deviceSensorMIB MODULE-IDENTITY + LAST-UPDATED "201511260300Z" + ORGANIZATION "Blue Coat Systems, Inc." + CONTACT-INFO "support.services@bluecoat.com + http://www.bluecoat.com" + DESCRIPTION "The sensor MIB is used to monitor + the values of sensors" + REVISION "201511260300Z" + DESCRIPTION "Add new value (notInstalled) to SensorStatus" + REVISION "201307110300Z" + DESCRIPTION "Access level for deviceSensorTrapEnabled changed." + REVISION "200711050300Z" + DESCRIPTION "Minor corrections and reformatting." + REVISION "200211060300Z" + DESCRIPTION "Initial revision of this MIB." + ::= { blueCoatMgmt 1 } + +deviceSensorMIBObjects + OBJECT IDENTIFIER ::= { deviceSensorMIB 1 } + +deviceSensorMIBNotifications + OBJECT IDENTIFIER ::= { deviceSensorMIB 2 } + +deviceSensorMIBNotificationsPrefix + OBJECT IDENTIFIER ::= { deviceSensorMIBNotifications 0 } + +-- textual conventions + +SensorUnits ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Sensor measurement unit types. Valid values are: + other(1) - a measure other than those listed below. + truthvalue(2) - value takes { true(1), false(2) }. + specialEnum(3) - value takes user defined enumerated values. + volts(4) - electrical potential. + celsius(5) - temperature. + rpm(6) - revolutions per minute." + SYNTAX INTEGER { + other(1), + truthvalue(2), + specialEnum(3), + volts(4), + celsius(5), + rpm(6) + } + +SensorCode ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Interpretation of the current sensor value." + SYNTAX INTEGER { + ok(1), + unknown(2), + notInstalled(3), + voltageLowWarning(4), + voltageLowCritical(5), + noPower(6), + voltageHighWarning(7), + voltageHighCritical(8), + voltageHighSevere(9), + temperatureHighWarning(10), + temperatureHighCritical(11), + temperatureHighSevere(12), + fanSlowWarning(13), + fanSlowCritical(14), + fanStopped(15) + } + +ExpBase10 ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION "Exponent base 10 for the current sensor value. + For example '-1' means value*(1/10)." + SYNTAX Integer32 (-24..24) + +SensorValue ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION "For sensors that measure volts and celsius, + this item is a fixed point number. + For sensors that measure rpm, this item + can take only nonnegative values. + For sensors of type truthvalue, this item + can take only two values: true(1), false(2). + For sensors of type specialEnum, this item + can take any value." + SYNTAX Integer32 (-1000000000..1000000000) + +SensorStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Indicates the operational status of the sensor. + ok(1) means the agent can read the sensor value. + unavailable(2) means that the agent presently + can not report the sensor value. + nonoperational(3) means that the sensor is broken. + notInstalled(4) means that the sensor or device is not present." + SYNTAX INTEGER { + ok(1), + unavailable(2), + nonoperational(3), + notInstalled(4) + } + +-- +-- MIB variables +-- + +deviceSensorValues + OBJECT IDENTIFIER ::= { deviceSensorMIBObjects 1 } + +-- +-- deviceSensorValueTable +-- + +deviceSensorValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF DeviceSensorValueEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table of sensors." + ::= { deviceSensorValues 1 } + +deviceSensorValueEntry OBJECT-TYPE + SYNTAX DeviceSensorValueEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An deviceSensorValueTable entry describes the + present reading of a sensor, the measurement units + and sensor operational status." + INDEX { deviceSensorIndex } + ::= { deviceSensorValueTable 1 } + +DeviceSensorValueEntry ::= SEQUENCE { + deviceSensorIndex INTEGER, + deviceSensorTrapEnabled TruthValue, + deviceSensorUnits SensorUnits, + deviceSensorScale ExpBase10, + deviceSensorValue SensorValue, + deviceSensorCode SensorCode, + deviceSensorStatus SensorStatus, + deviceSensorTimeStamp TimeStamp, + deviceSensorName DisplayString + } + +deviceSensorIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An arbitrary value which uniquely identifies the sensor" + ::= { deviceSensorValueEntry 1 } + +deviceSensorTrapEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable controls generation of + deviceSensorTrap for this sensor. + When this variable is true(1), generation of + deviceSensorTrap is enabled. When this variable + is false(2), generation of deviceSensorTrap is + disabled. The default start-up value is true(1)." + ::= { deviceSensorValueEntry 2 } + +deviceSensorUnits OBJECT-TYPE + SYNTAX SensorUnits + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable indicates the type of data + reported by the deviceSensorValue. + This variable is set by the agent at start-up + and the value does not change during operation." + ::= { deviceSensorValueEntry 3 } + +deviceSensorScale OBJECT-TYPE + SYNTAX ExpBase10 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power of 10 to apply to the value + reported by the deviceSensorValue. + This variable is set by the agent at start-up + and the value does not change during operation." + ::= { deviceSensorValueEntry 4 } + +deviceSensorValue OBJECT-TYPE + SYNTAX SensorValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable reports the most recent measurement + seen by the sensor. To correctly display or interpret + this variable's value, you must also know + deviceSensorUnits." + ::= { deviceSensorValueEntry 5 } + +deviceSensorCode OBJECT-TYPE + SYNTAX SensorCode + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable reports how to interpret + deviceSensorValue for the sensor." + ::= { deviceSensorValueEntry 6 } + +deviceSensorStatus OBJECT-TYPE + SYNTAX SensorStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable indicates the present operational + status of the sensor." + ::= { deviceSensorValueEntry 7 } + +deviceSensorTimeStamp OBJECT-TYPE + SYNTAX TimeStamp + UNITS "Hundredths of seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This variable indicates the age of the value + reported by deviceSensorValue." + ::= { deviceSensorValueEntry 8 } + +deviceSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The textual name of the sensor." + ::= { deviceSensorValueEntry 9 } + +-- +-- notifications +-- + +deviceSensorTrap NOTIFICATION-TYPE + OBJECTS { deviceSensorName, deviceSensorValue, deviceSensorCode } + STATUS current + DESCRIPTION "The sensor value warrants a notification." + ::= { deviceSensorMIBNotificationsPrefix 1 } + +END |