diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/avtech/ROOMALERT3E-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/avtech/ROOMALERT3E-MIB')
| -rw-r--r-- | MIBS/avtech/ROOMALERT3E-MIB | 183 |
1 files changed, 183 insertions, 0 deletions
diff --git a/MIBS/avtech/ROOMALERT3E-MIB b/MIBS/avtech/ROOMALERT3E-MIB new file mode 100644 index 0000000..bd0bba8 --- /dev/null +++ b/MIBS/avtech/ROOMALERT3E-MIB @@ -0,0 +1,183 @@ +-- +--defines ROOMALERT3E-MIB for SNMP agent extension of Room Alert 3E +--Contents: Global Registration Module +-- Room Alert OIDs - Enterprise 20916 +--Version: 1.0.1 +--Date: WEB_RELEASE_DATE_PLACEHOLDER +--Developed By: AVTECH Software, Inc. + +-- +--Copyright (c) COPYRIGHT_YEAR_PLACEHOLDER AVTECH Software, Inc. +-- + +ROOMALERT3E-MIB DEFINITIONS ::= BEGIN + + +IMPORTS + enterprises, IpAddress, Counter, TimeTicks + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215; + + +avtech OBJECT IDENTIFIER ::= { enterprises 20916 } +products OBJECT IDENTIFIER ::= { avtech 1 } +ROOMALERT3E OBJECT IDENTIFIER ::= { products 9 } +sensors OBJECT IDENTIFIER ::= { ROOMALERT3E 1 } +signaltower OBJECT IDENTIFIER ::= { ROOMALERT3E 2 } +traps OBJECT IDENTIFIER ::= { ROOMALERT3E 3 } +digital OBJECT IDENTIFIER ::= { sensors 1 } +digital-sen1 OBJECT IDENTIFIER ::= { digital 1 } +digital-sen2 OBJECT IDENTIFIER ::= { digital 2 } +switch OBJECT IDENTIFIER ::= { sensors 2 } + + +-- Room Alert 3E MIB +-- Parameters + +digital-sen1-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The current temperature reading in Celsius of the Internal Temperature Sensor." +::= { digital-sen1 1 } + +digital-sen1-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The current temperature reading in Fahrenheit of the Internal Temperature Sensor." +::= { digital-sen1 2 } + +digital-sen1-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label of this sensor" +::= {digital-sen1 3} + +digital-sen2-1 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius." +::= { digital-sen2 1 } + +digital-sen2-2 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit." +::= { digital-sen2 2 } + +digital-sen2-3 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity." +::= { digital-sen2 3 } + +digital-sen2-4 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit." +::= { digital-sen2 4 } + +digital-sen2-5 OBJECT-TYPE + SYNTAX INTEGER(0..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius." +::= { digital-sen2 5 } + +digital-sen2-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label of this sensor" +::= {digital-sen2 6} + +switch-sen1 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-only + STATUS mandatory + DESCRIPTION "The reading for the switch sensor (0 = OPEN, 1 = CLOSED)." +::= { switch 1 } + +switch-label OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "The label for the switch sensor" +::= { switch 2 } + +red-led OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 1 } + +amber-led OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 2 } + +green-led OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 3 } + +blue-led OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 4 } + +white-led OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 5 } + +alarm1 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 6 } + +alarm2 OBJECT-TYPE + SYNTAX INTEGER(0..1) + ACCESS read-write + STATUS current + DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." +::= { signaltower 7 } + +alarmmessage OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Last Alarm Message" +::= { traps 1 } + + +-- ROOMALERT3E TRAPS + +room-alert-3e-snmp-trap TRAP-TYPE + ENTERPRISE ROOMALERT3E + VARIABLES { alarmmessage } + DESCRIPTION "A room-alert-3e-snmp-trap indicates that an alarm + condition has occurred on the sensor indicated + by the alarmmessage variable." +::= 2 +END |