diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/audiocodes/AC-PMPSTN-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/audiocodes/AC-PMPSTN-MIB')
| -rw-r--r-- | MIBS/audiocodes/AC-PMPSTN-MIB | 824 |
1 files changed, 824 insertions, 0 deletions
diff --git a/MIBS/audiocodes/AC-PMPSTN-MIB b/MIBS/audiocodes/AC-PMPSTN-MIB new file mode 100644 index 0000000..0c0adac --- /dev/null +++ b/MIBS/audiocodes/AC-PMPSTN-MIB @@ -0,0 +1,824 @@ +
+AC-PM-PSTN-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+
+
+ OBJECT-TYPE,
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TAddress,
+ DisplayString,
+ DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
+ IpAddress FROM RFC1155-SMI
+ Unsigned32,
+ Integer32,
+ enterprises FROM SNMPv2-SMI
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ audioCodes,
+ acRegistrations,
+ acGeneric,
+ acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
+
+
+acPMPSTN MODULE-IDENTITY
+ LAST-UPDATED "200902050516Z" --Thursday, February 05, 2009
+ ORGANIZATION "AudioCodes Ltd"
+ CONTACT-INFO
+ "Postal: Support
+ AudioCodes LTD
+ 1 Hayarden Street
+ Airport City
+ Lod, ISRAEL 70151
+ Tel: 972-3-9764000
+ Fax: 972-3-9764040
+ Email: support@audiocodes.com
+ Web: www.audiocodes.com"
+
+
+ DESCRIPTION
+ "The AC-PM-PSTN MIB offers performance monitoring
+For the PSTN related elements in Audiocodes' devices.
+The Configuration sub-tree is for configuring the interval
+Period length for the entire AC-PM-PSTN MIB, and the
+different tables' thresholds.
+The Data sub-tree presents the tables of monitored
+elements.
+
+Note - for the entire MIB the value (-1) means the value
+Asked for is either not supported or currently not relevant
+(this is for when values asked for are for intervals not yet
+recorded."
+
+
+
+ ::= {acPerformance 10}
+
+
+
+
+
+
+
+
+ acPMPSTNConfiguration OBJECT IDENTIFIER ::= {acPMPSTN 1}
+
+
+ acPMPSTNConfigurationPeriodLength OBJECT-TYPE
+ SYNTAX Unsigned32 (0..894780)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Length of monitoring intervals for entire MIB. Time is in minutes.
+Access: Instant."
+ ::= {acPMPSTNConfiguration 1}
+
+
+
+ acPMPSTNConfigurationResetTotalCounters OBJECT-TYPE
+ SYNTAX INTEGER {
+ resetCountersDone(1)
+,
+ resetTotalCounters(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Total-Counters Reset. To reset the total counters, set the
+value of this object to resetTotalCounters(2).
+Access: Instant."
+ ::= {acPMPSTNConfiguration 2}
+
+
+
+ acPMTrunkUtilizationAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 31}
+
+
+ acPMTrunkUtilizationAttributesHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold.
+Access: Instant."
+ ::= {acPMTrunkUtilizationAttributes 1}
+
+
+
+ acPMTrunkUtilizationAttributesLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold.
+Access: Instant."
+ ::= {acPMTrunkUtilizationAttributes 2}
+
+
+
+ acPMPSTNChannelsAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 32}
+
+
+ acPMPSTNChannelsAttributesInServiceHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 1}
+
+
+
+ acPMPSTNChannelsAttributesInServiceLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 2}
+
+
+
+ acPMPSTNChannelsAttributesOutOfServiceHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 3}
+
+
+
+ acPMPSTNChannelsAttributesOutOfServiceLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 4}
+
+
+
+ acPMPSTNChannelsAttributesInMaintenanceHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "High threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 5}
+
+
+
+ acPMPSTNChannelsAttributesInMaintenanceLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Low threshold.
+Access: Instant."
+ ::= {acPMPSTNChannelsAttributes 6}
+
+
+
+ acPMPSTNData OBJECT IDENTIFIER ::= {acPMPSTN 2}
+
+
+ acPMPSTNDataAcPMPSTNTimeFromStartOfInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time in seconds since the start of the current interval.
+MIB specific."
+ ::= {acPMPSTNData 1}
+
+
+
+ -- ****************************************
+ -- acPMTrunkUtilization table declaration
+ -- ****************************************
+ acPMTrunkUtilizationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMTrunkUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of active channels per trunk (index: trunk number)."
+ ::= {acPMPSTNData 21}
+
+
+
+ -- ****************************************
+ -- acPMTrunkUtilization table entry
+ -- ****************************************
+ acPMTrunkUtilizationEntry OBJECT-TYPE
+ SYNTAX AcPMTrunkUtilizationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMTrunkUtilizationTrunkNum,acPMTrunkUtilizationInterval}
+ ::= {acPMTrunkUtilizationTable 1}
+
+
+
+ -- ****************************************
+ -- acPMTrunkUtilization TABLE
+ -- ****************************************
+ AcPMTrunkUtilizationEntry ::= SEQUENCE {
+ acPMTrunkUtilizationTrunkNum Unsigned32,
+ acPMTrunkUtilizationInterval Unsigned32,
+ acPMTrunkUtilizationVal Gauge32,
+ acPMTrunkUtilizationAverage Integer32,
+ acPMTrunkUtilizationMax Integer32,
+ acPMTrunkUtilizationMin Integer32,
+ acPMTrunkUtilizationVolume Counter32,
+ acPMTrunkUtilizationTimeBelowLowThreshold Integer32,
+ acPMTrunkUtilizationTimeBetweenThresholds Integer32,
+ acPMTrunkUtilizationTimeAboveHighThreshold Integer32,
+ acPMTrunkUtilizationFullDayAverage Integer32,
+ acPMTrunkUtilizationTotal Integer32
+ }
+
+
+
+ acPMTrunkUtilizationTrunkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trunk number.
+0 is the first trunk."
+ ::= {acPMTrunkUtilizationEntry 1}
+
+
+
+ acPMTrunkUtilizationInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMTrunkUtilizationEntry 2}
+
+
+
+ acPMTrunkUtilizationVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMTrunkUtilizationEntry 3}
+
+
+
+ acPMTrunkUtilizationAverage OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average value within the period time."
+ ::= {acPMTrunkUtilizationEntry 4}
+
+
+
+ acPMTrunkUtilizationMax OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum value within the period time."
+ ::= {acPMTrunkUtilizationEntry 5}
+
+
+
+ acPMTrunkUtilizationMin OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum value within the period time."
+ ::= {acPMTrunkUtilizationEntry 6}
+
+
+
+ acPMTrunkUtilizationVolume OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Activity volume."
+ ::= {acPMTrunkUtilizationEntry 7}
+
+
+
+ acPMTrunkUtilizationTimeBelowLowThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is below what was determined
+as the low threshold."
+ ::= {acPMTrunkUtilizationEntry 8}
+
+
+
+ acPMTrunkUtilizationTimeBetweenThresholds OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is above what was determined
+as the high threshold."
+ ::= {acPMTrunkUtilizationEntry 9}
+
+
+
+ acPMTrunkUtilizationTimeAboveHighThreshold OBJECT-TYPE
+ SYNTAX Integer32 (-1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percent of interval time for which gauge is between what were
+determined as the low and high thresholds."
+ ::= {acPMTrunkUtilizationEntry 10}
+
+
+
+ acPMTrunkUtilizationFullDayAverage OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average of full 24 hours."
+ ::= {acPMTrunkUtilizationEntry 11}
+
+
+
+ acPMTrunkUtilizationTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMTrunkUtilizationEntry 12}
+
+
+
+ -- ****************************************
+ -- acPMPSTNTrunkActivitySeconds table declaration
+ -- ****************************************
+ acPMPSTNTrunkActivitySecondsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMPSTNTrunkActivitySecondsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Counts activity seconds on the trunk."
+ ::= {acPMPSTNData 22}
+
+
+
+ -- ****************************************
+ -- acPMPSTNTrunkActivitySeconds table entry
+ -- ****************************************
+ acPMPSTNTrunkActivitySecondsEntry OBJECT-TYPE
+ SYNTAX AcPMPSTNTrunkActivitySecondsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMPSTNTrunkActivitySecondsTrunkNum,acPMPSTNTrunkActivitySecondsInterval}
+ ::= {acPMPSTNTrunkActivitySecondsTable 1}
+
+
+
+ -- ****************************************
+ -- acPMPSTNTrunkActivitySeconds TABLE
+ -- ****************************************
+ AcPMPSTNTrunkActivitySecondsEntry ::= SEQUENCE {
+ acPMPSTNTrunkActivitySecondsTrunkNum Unsigned32,
+ acPMPSTNTrunkActivitySecondsInterval Unsigned32,
+ acPMPSTNTrunkActivitySecondsVal Gauge32,
+ acPMPSTNTrunkActivitySecondsTotal Integer32,
+ acPMPSTNTrunkActivitySecondsVolume Counter32
+ }
+
+
+
+ acPMPSTNTrunkActivitySecondsTrunkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trunk number.
+0 is the first trunk."
+ ::= {acPMPSTNTrunkActivitySecondsEntry 1}
+
+
+
+ acPMPSTNTrunkActivitySecondsInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMPSTNTrunkActivitySecondsEntry 2}
+
+
+
+ acPMPSTNTrunkActivitySecondsVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMPSTNTrunkActivitySecondsEntry 3}
+
+
+
+ acPMPSTNTrunkActivitySecondsTotal OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total since last reset."
+ ::= {acPMPSTNTrunkActivitySecondsEntry 4}
+
+
+
+ acPMPSTNTrunkActivitySecondsVolume OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Activity volume."
+ ::= {acPMPSTNTrunkActivitySecondsEntry 5}
+
+
+
+ acPMPSTNChannels OBJECT IDENTIFIER ::= {acPMPSTNData 31}
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInService table declaration
+ -- ****************************************
+ acPMPSTNNumOfChannelsInServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Channels in service, per trunk."
+ ::= {acPMPSTNChannels 1}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInService table entry
+ -- ****************************************
+ acPMPSTNNumOfChannelsInServiceEntry OBJECT-TYPE
+ SYNTAX AcPMPSTNNumOfChannelsInServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMPSTNNumOfChannelsInServiceTrunkNum,acPMPSTNNumOfChannelsInServiceInterval}
+ ::= {acPMPSTNNumOfChannelsInServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInService TABLE
+ -- ****************************************
+ AcPMPSTNNumOfChannelsInServiceEntry ::= SEQUENCE {
+ acPMPSTNNumOfChannelsInServiceTrunkNum Unsigned32,
+ acPMPSTNNumOfChannelsInServiceInterval Unsigned32,
+ acPMPSTNNumOfChannelsInServiceVal Gauge32,
+ acPMPSTNNumOfChannelsInServiceAverage Integer32,
+ acPMPSTNNumOfChannelsInServiceMax Integer32,
+ acPMPSTNNumOfChannelsInServiceMin Integer32,
+ acPMPSTNNumOfChannelsInServiceVolume Counter32
+ }
+
+
+
+ acPMPSTNNumOfChannelsInServiceTrunkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trunk number.
+0 is the first trunk."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 1}
+
+
+
+ acPMPSTNNumOfChannelsInServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 2}
+
+
+
+ acPMPSTNNumOfChannelsInServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 3}
+
+
+
+ acPMPSTNNumOfChannelsInServiceAverage OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average value within the period time."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 4}
+
+
+
+ acPMPSTNNumOfChannelsInServiceMax OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum value within the period time."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 5}
+
+
+
+ acPMPSTNNumOfChannelsInServiceMin OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum value within the period time."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 6}
+
+
+
+ acPMPSTNNumOfChannelsInServiceVolume OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Activity volume."
+ ::= {acPMPSTNNumOfChannelsInServiceEntry 7}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsOutOfService table declaration
+ -- ****************************************
+ acPMPSTNNumOfChannelsOutOfServiceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Channels out of service, per trunk."
+ ::= {acPMPSTNChannels 2}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsOutOfService table entry
+ -- ****************************************
+ acPMPSTNNumOfChannelsOutOfServiceEntry OBJECT-TYPE
+ SYNTAX AcPMPSTNNumOfChannelsOutOfServiceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMPSTNNumOfChannelsOutOfServiceTrunkNum,acPMPSTNNumOfChannelsOutOfServiceInterval}
+ ::= {acPMPSTNNumOfChannelsOutOfServiceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsOutOfService TABLE
+ -- ****************************************
+ AcPMPSTNNumOfChannelsOutOfServiceEntry ::= SEQUENCE {
+ acPMPSTNNumOfChannelsOutOfServiceTrunkNum Unsigned32,
+ acPMPSTNNumOfChannelsOutOfServiceInterval Unsigned32,
+ acPMPSTNNumOfChannelsOutOfServiceVal Gauge32,
+ acPMPSTNNumOfChannelsOutOfServiceAverage Integer32,
+ acPMPSTNNumOfChannelsOutOfServiceMax Integer32,
+ acPMPSTNNumOfChannelsOutOfServiceMin Integer32,
+ acPMPSTNNumOfChannelsOutOfServiceVolume Counter32
+ }
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceTrunkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trunk number.
+0 is the first trunk."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 1}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 2}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 3}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceAverage OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average value within the period time."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 4}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceMax OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum value within the period time."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 5}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceMin OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum value within the period time."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 6}
+
+
+
+ acPMPSTNNumOfChannelsOutOfServiceVolume OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Activity volume."
+ ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 7}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInMaintenance table declaration
+ -- ****************************************
+ acPMPSTNNumOfChannelsInMaintenanceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInMaintenanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Channels in maintenance status (not in-service), per trunk."
+ ::= {acPMPSTNChannels 3}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInMaintenance table entry
+ -- ****************************************
+ acPMPSTNNumOfChannelsInMaintenanceEntry OBJECT-TYPE
+ SYNTAX AcPMPSTNNumOfChannelsInMaintenanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acPMPSTNNumOfChannelsInMaintenanceTrunkNum,acPMPSTNNumOfChannelsInMaintenanceInterval}
+ ::= {acPMPSTNNumOfChannelsInMaintenanceTable 1}
+
+
+
+ -- ****************************************
+ -- acPMPSTNNumOfChannelsInMaintenance TABLE
+ -- ****************************************
+ AcPMPSTNNumOfChannelsInMaintenanceEntry ::= SEQUENCE {
+ acPMPSTNNumOfChannelsInMaintenanceTrunkNum Unsigned32,
+ acPMPSTNNumOfChannelsInMaintenanceInterval Unsigned32,
+ acPMPSTNNumOfChannelsInMaintenanceVal Gauge32,
+ acPMPSTNNumOfChannelsInMaintenanceAverage Integer32,
+ acPMPSTNNumOfChannelsInMaintenanceMax Integer32,
+ acPMPSTNNumOfChannelsInMaintenanceMin Integer32,
+ acPMPSTNNumOfChannelsInMaintenanceVolume Counter32
+ }
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceTrunkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Trunk number.
+0 is the first trunk."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 1}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Interval index.
+0 - current period (incomplete monitoring - mid period).
+1 - Last full period.
+2 - One before last."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 2}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceVal OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of gauge or counter."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 3}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceAverage OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average value within the period time."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 4}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceMax OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum value within the period time."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 5}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceMin OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Minimum value within the period time."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 6}
+
+
+
+ acPMPSTNNumOfChannelsInMaintenanceVolume OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Activity volume."
+ ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 7}
+
+
+
+
+
+END
|