summaryrefslogtreecommitdiff
path: root/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB')
-rw-r--r--MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB181
1 files changed, 181 insertions, 0 deletions
diff --git a/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB b/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB
new file mode 100644
index 0000000..c6c62f1
--- /dev/null
+++ b/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB
@@ -0,0 +1,181 @@
+ ARRIS-D5-ENT-SENSOR-THRESH-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ packetport, cm110, tcm, ttm, ttp,
+ cmtsMSAS, cmts1500, cmtsC3, cmtsC4, cmtsCommon,
+ mrcController, arrisGlobalAccessMib, arrisGlobalAccessProductUas, arrisD5UEQam
+ FROM ARRIS-MIB
+ entPhysicalIndex, entityPhysicalGroup
+ FROM ENTITY-MIB
+ entPhySensorType, entPhySensorScale, entPhySensorPrecision, entPhySensorValue, entPhySensorOperStatus,
+ entPhySensorUnitsDisplay, entPhySensorValueTimeStamp, entPhySensorValueUpdateRate, entitySensorCompliance, entitySensorValueGroup,
+ entPhySensorEntry
+ FROM ENTITY-SENSOR-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ Integer32, OBJECT-TYPE, MODULE-IDENTITY
+ FROM SNMPv2-SMI;
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4
+ arrisEntSensorThreshMIB MODULE-IDENTITY
+ LAST-UPDATED "200710100000Z" -- 10th Oct 2007
+ ORGANIZATION
+ "Arris"
+ CONTACT-INFO
+ "Cindy Tromer
+ Postal: Arris Interactive
+ 3871 Lakefield Drive
+ Suite 300
+ Suwanee, GA 30024-1242
+ U.S.A.
+ Phone: +1 770 622 8679
+ E-mail: cindy.tromer@arrisi.com
+
+ Initial MIB creator: Cindy Tromer
+ Postal: Arris Interactive
+ 3871 Lakefield Drive
+ Suite 300
+ Suwanee, GA 30024-1242
+ U.S.A.
+ Phone: +1 770 622 8679
+ E-mail: cindy.tromer@arrisi.com
+ "
+ DESCRIPTION
+ "This is the extension Module to rfc3433 ENTITY-SENSOR-MIB."
+ ::= { arrisD5UEQam 4 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1
+ entThreshObjects OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 1 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1
+ entThreshTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EntThreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains one row per physical sensor.
+
+ Each row contains the set of thresholds maintained
+ for each pyhsical sensor."
+ ::= { entThreshObjects 1 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1
+ entThreshEntry OBJECT-TYPE
+ SYNTAX EntThreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The threshold information for a particular
+ physical sensor.
+
+ An entry in this table describes the upper and lower warning
+ thresholds, as well as the upper and lower fatal thresholds."
+ AUGMENTS { entPhySensorEntry }
+ ::= { entThreshTable 1 }
+
+
+ EntThreshEntry ::=
+ SEQUENCE {
+ entLowerWarnThresh
+ Integer32,
+ entUpperWarnThresh
+ Integer32,
+ entLowerFatalThresh
+ Integer32,
+ entUpperFatalThresh
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.1
+ entLowerWarnThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lower warning threshold for a physical sensor.
+ When a sensor value goes below this threshold, the
+ system will continue to operate, but the craftperson
+ should evaluate the problem. "
+ ::= { entThreshEntry 1 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.2
+ entUpperWarnThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The upper warning threshold for a physical sensor.
+ When a sensor value goes above this threshold, the
+ system will continue to operate, but the craftperson
+ should evaluate the problem. "
+ ::= { entThreshEntry 2 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.3
+ entLowerFatalThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lower fatal threshold for a physical sensor.
+ When a sensor value goes below this threshold, the
+ system will shutdown."
+ ::= { entThreshEntry 3 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.4
+ entUpperFatalThresh OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The upper fatal threshold for a physical sensor.
+ When a sensor value goes above this threshold, the
+ system will shutdown."
+ ::= { entThreshEntry 4 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.2
+ entThreshConformance OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 2 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.2.1
+ entThreshCompliances OBJECT IDENTIFIER ::= { entThreshConformance 1 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.2.1.1
+ entThreshCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "Description."
+ MODULE -- this module
+ MANDATORY-GROUPS { entThreshValueGroup }
+ ::= { entThreshCompliances 1 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.2.2
+ entThreshGroups OBJECT IDENTIFIER ::= { entThreshConformance 2 }
+
+
+ -- 1.3.6.1.4.1.4115.1.7.1.4.2.2.1
+ entThreshValueGroup OBJECT-GROUP
+ OBJECTS { entLowerWarnThresh, entUpperWarnThresh, entUpperFatalThresh, entLowerFatalThresh }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { entThreshGroups 1 }
+
+
+
+ END