summaryrefslogtreecommitdiff
path: root/MIBS/allied/AT-INTERFACES-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/allied/AT-INTERFACES-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/allied/AT-INTERFACES-MIB')
-rw-r--r--MIBS/allied/AT-INTERFACES-MIB496
1 files changed, 496 insertions, 0 deletions
diff --git a/MIBS/allied/AT-INTERFACES-MIB b/MIBS/allied/AT-INTERFACES-MIB
new file mode 100644
index 0000000..a6b5e3c
--- /dev/null
+++ b/MIBS/allied/AT-INTERFACES-MIB
@@ -0,0 +1,496 @@
+-- ============================================================================
+-- AT-INTERFACE.MIB, Allied Telesis enterprise MIB: Interfaces
+--
+-- Extracted from ATROUTER.MIB of pre 2.9.1 release
+--
+-- June 2006, Stan Xiang
+-- Upgraded to SMIv2 compliance
+--
+-- Copyright (c) 2006 by Allied Telesis, Inc.
+-- All rights reserved.
+--
+-- ============================================================================
+
+AT-INTERFACES-MIB DEFINITIONS ::= BEGIN
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ DisplayString
+ FROM SNMPv2-TC
+ ifName,
+ InterfaceIndexOrZero
+ FROM IF-MIB
+ traps,
+ atRouter
+ FROM AT-SMI-MIB
+;
+
+arInterfaces MODULE-IDENTITY
+ LAST-UPDATED "200606140000Z"
+ ORGANIZATION "Allied Telesis, Inc."
+ CONTACT-INFO
+ " http://www.alliedtelesis.com"
+ DESCRIPTION
+ "subtree beneath which interface ids are assigned.."
+ REVISION "200606140000Z"
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { atRouter 5 }
+
+
+-- Generic traps
+
+igmpTraps OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "object id for igmp traps."
+ ::= { traps 1 }
+
+igmpGeneralQueryNotReceivedEvent NOTIFICATION-TYPE
+ OBJECTS { ifName }
+ STATUS current
+ DESCRIPTION
+ "Triggered when no general IGMP-Query
+ message is received within a user-defined
+ time period on a specific interface."
+::= { igmpTraps 1 }
+
+
+
+-- Router interfaces tables.
+
+-- A router consists of a number of "boards". Each board may have a
+-- number of "positions", each of which contains a single router
+-- interface. Each boards may also have a number of "slots", which are
+-- places which can take other boards. Thus the physical construction
+-- of a router may be seen as a tree whose nodes are boards and
+-- interfaces, and whose links are positions and slots.
+-- For example, an AR720 with a single Ethernet ICM in Bay 1 has the
+-- following tree:
+-- Bd:AR720 base board
+-- === P1 === Int: Asyn0
+-- === P2 === Int: Asyn1
+-- === P3 === Int: Eth0
+-- === S1 (Bay0) === <empty>
+-- === S2 (Bay1) === Bd:Ethernet ICM === P1 === Int: Eth1
+-- === S3 (MAC) === <empty>
+-- The function of the interface MIB tables is to represent this tree
+-- and to map elements in this tree to other MIB variables. Note that
+-- any given board has a fixed configuration of positions and slots,
+-- it is what is contained in the slots that give different hardware
+-- configurations.
+
+-- The highest index of boards in this router. Boards will have indices
+-- from 1 to the value of this object. There may be gaps in the
+-- sequence if the router has hot-swap capability. If the router has no
+-- hot-swap capability, or no swapping has taken place since boot, the
+-- sequence of boards will have no gaps.
+
+arBoardMaxIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum index of boards in the board table. Index 1
+ is reserved for the main system board of the router."
+ ::= { arInterfaces 1 }
+
+-- Router boards table. This table describes all of the physical boards
+-- present in this router. A board is defined as a separate circuit
+-- board with its own serial number.
+
+arBoardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ArBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of boards in the AR router."
+ ::= { arInterfaces 2 }
+
+arBoardEntry OBJECT-TYPE
+ SYNTAX ArBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A single entry in the board table. Each entry consists
+ of information about one board in the router."
+ INDEX { arBoardIndex }
+ ::= { arBoardTable 1 }
+
+ArBoardEntry ::=
+ SEQUENCE {
+ arBoardIndex
+ INTEGER,
+ arBoardId
+ OBJECT IDENTIFIER,
+ arBoardName
+ DisplayString,
+ arBoardRevision
+ DisplayString,
+ arBoardSerialNumber
+ DisplayString,
+ arBoardTotalSlots
+ INTEGER,
+ arBoardTotalPositions
+ INTEGER
+ }
+
+arBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the board in the board table. Index 1 is
+ reserved for the main system board of the router. Other
+ boards will take index numbers as they are initialised
+ at router startup, or for routers with hot-swap
+ capability, as boards are added to and removed from the
+ router."
+ ::= { arBoardEntry 1 }
+
+arBoardId OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of board in this board entry. The values of
+ this object are taken from the pprXxx object IDs under
+ the boards sub-tree."
+ ::= { arBoardEntry 2 }
+
+arBoardName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the board in this board entry. This is a
+ readable string which identifies the board to the
+ manager."
+ ::= { arBoardEntry 3 }
+
+arBoardRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturing revision of the board in this board
+ entry. This string has the format Xm-n, where X is P for
+ prototype, or M for manufacturing, m is the major
+ revision number for this board, and n is the field
+ upgrade revision number for this board."
+ ::= { arBoardEntry 4 }
+
+arBoardSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the board in this board entry.
+ Serial numbers are strings of decimal numbers up to 10
+ digits in length. Each and every serial number is
+ globally unique. It is possible for the serial number of
+ a board to be invalid. In this case the value returned
+ for this object will be '*** Invalid ***'"
+ ::= { arBoardEntry 5 }
+
+arBoardTotalSlots OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of slots on this board. Each slot from 1 to
+ the value of this object may be empty or occupied by
+ another board. By searching the arSlotTable with this
+ board's board index and all values of slot index from 1
+ to the value of this object, a tree of the boards in
+ this router can be built. The value 0 for this object
+ means that it has no slots."
+ ::= { arBoardEntry 6 }
+
+arBoardTotalPositions OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of positions on this board. Each position
+ from 1 to the value of this object contains a single
+ router interface. Note that positions are different from
+ slots. An position contains an actual interface while a
+ slot contains a different board which itself may contain
+ interfaces in its positions."
+ ::= { arBoardEntry 7 }
+
+
+-- Router board slot table. This table is indexed by board index and
+-- slot index and gives the board index of the board occupying the
+-- given slot in the given board.
+
+arSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ArSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of slots in the router, indexed by board
+ index and slot index."
+ ::= { arInterfaces 3 }
+
+arSlotEntry OBJECT-TYPE
+ SYNTAX ArSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A single entry in the board slot table."
+ INDEX { arSlotBoardIndex, arSlotSlotIndex }
+ ::= { arSlotTable 1 }
+
+ArSlotEntry ::=
+ SEQUENCE {
+ arSlotBoardIndex
+ INTEGER,
+ arSlotSlotIndex
+ INTEGER,
+ arSlotHeldBoardIndex
+ INTEGER,
+ arSlotDescription
+ DisplayString
+ }
+
+arSlotBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the board for this slot entry. Index 1 is
+ reserved for the main system board of the router."
+ ::= { arSlotEntry 1 }
+
+arSlotSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the slot for this slot entry. Indices
+ start from 1 and are specific to each different board
+ type. There are no gaps in the sequence of slot indices.
+ The maximum value for slot index is given by the value
+ of arBoardTotalSlots for this board."
+ ::= { arSlotEntry 2 }
+
+arSlotHeldBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the board held in the slot for this slot
+ entry. This is an index into the arBoardTable. A value
+ of 0 for this object means that the slot is not
+ populated."
+ ::= { arSlotEntry 3 }
+
+arSlotDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A description for this slot entry. This is a textual
+ description which gives the manager a clue as to what
+ the slot for this entry is. For example, the slots on an
+ AR 720 have descriptions 'Bay0', 'Bay1' and 'MAC'."
+ ::= { arSlotEntry 4 }
+
+-- Router interfaces table. This table has an entry for each physical
+-- interface on the router. The indices for this table are the router
+-- board index and a board position index.
+
+arInterfaceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ArInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of physical interfaces in the AR router."
+ ::= { arInterfaces 4 }
+
+arInterfaceEntry OBJECT-TYPE
+ SYNTAX ArInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A single entry in the interface table. Each entry consists of
+ information about one interface in the router, and is indexed
+ by the board index and the position of the interface on the
+ board."
+ INDEX { arInterfaceBoardIndex, arInterfacePosition }
+ ::= { arInterfaceTable 1 }
+
+ArInterfaceEntry ::=
+ SEQUENCE {
+ arInterfaceBoardIndex
+ INTEGER,
+ arInterfacePosition
+ INTEGER,
+ arInterfaceIfIndex
+ InterfaceIndexOrZero,
+ arInterfaceName
+ DisplayString,
+ arInterfaceFullName
+ DisplayString
+ }
+
+arInterfaceBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the board in the board table which contains this
+ interface. Index 1 is reserved for the main system board of the
+ router."
+ ::= { arInterfaceEntry 1 }
+
+arInterfacePosition OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The position of the interface on the board. Each board type
+ will have well-known positions which are the interfaces
+ provided by the board. The number of positions on a given board
+ is given by the object arBoardTotalPositions for this board."
+ ::= { arInterfaceEntry 2 }
+
+arInterfaceIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ifIndex for the interface represented by this entry of the
+ interfaces table. This is the ifIndex of the ifEntry used to
+ represent the physical interface. The value 0 is used for
+ interfaces which don't have an ifIndex."
+ ::= { arInterfaceEntry 3 }
+
+arInterfaceName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of this interface. This is the name that the manager
+ can use to refer to this interface in entering router
+ commands."
+ ::= { arInterfaceEntry 4 }
+
+
+arInterfaceFullName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The fully qualified name for this interface. This identifies
+ the path that must be followed to reach the interface. This
+ name can be used in router commands. In routers don't support
+ fully qualified names, this is the same as arInterfaceName."
+ ::= { arInterfaceEntry 5 }
+
+-- =================================================================================
+-- Router interface extension table. This table extends ifTable to allow interface variables
+-- not covered in the standard MIB. Current variables include:
+-- 1. 512s moving averages of interface throughput, bps and pps.
+
+arIfXTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ArIfXEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of interface statistics for the AR router.
+ This table extends the ifTable."
+ ::= { arInterfaces 5 }
+
+arIfXEntry OBJECT-TYPE
+ SYNTAX ArIfXEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A single entry in the interface extension table. Each entry consists of
+ extra interface information not covered in standard MIBs. The index for this
+ table is ifIndex, the same as for ifTable."
+ INDEX { arIfXIndex }
+ ::= { arIfXTable 1 }
+
+ArIfXEntry ::=
+ SEQUENCE {
+ arIfXIndex
+ INTEGER,
+ arIfXAverageInputBitsSecond
+ INTEGER,
+ arIfXAverageInputPacketsSecond
+ INTEGER,
+ arIfXAverageOutputBitsSecond
+ INTEGER,
+ arIfXAverageOutputPacketsSecond
+ INTEGER
+ }
+
+arIfXIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the ifTable."
+ ::= { arIfXEntry 1 }
+
+arIfXAverageInputBitsSecond OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average number of bits received per second on all
+ interfaces over the past 8.5 minutes.
+
+ The average is calculated by an 8.5 minute (512s) decaying average,
+ which is updated every 4 seconds using the following formula:
+
+ X' = 127/128X + 1/128i
+
+ where X' is the new average
+ X is the old average
+ i is the most recent poll result
+
+ The times and multiplier factors have been chosen to give the simplest
+ possible calculation using bit shifting operations."
+ ::= { arIfXEntry 2 }
+
+ arIfXAverageInputPacketsSecond OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average number of packets received per second on all
+ interfaces over the past 8.5 minutes. See the description for
+ arIfXAverageInputBitsSecond for details of the way in which the
+ average is calculated."
+ ::= { arIfXEntry 3 }
+
+ arIfXAverageOutputBitsSecond OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average number of bits sent per second on all
+ interfaces over the past 8.5 minutes. See the description for
+ arIfXAverageInputBitsSecond for details of the way in which the
+ average is calculated."
+ ::= { arIfXEntry 4 }
+
+ arIfXAverageOutputPacketsSecond OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The average number of bits sent per second on all
+ interfaces over the past 8.5 minutes. See the description for
+ arIfXAverageInputBitsSecond for details of the way in which the
+ average is calculated."
+ ::= { arIfXEntry 5 }
+
+END