diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/FRAME-RELAY-DTE-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/FRAME-RELAY-DTE-MIB')
| -rw-r--r-- | MIBS/FRAME-RELAY-DTE-MIB | 1084 |
1 files changed, 1084 insertions, 0 deletions
diff --git a/MIBS/FRAME-RELAY-DTE-MIB b/MIBS/FRAME-RELAY-DTE-MIB new file mode 100644 index 0000000..eb92aeb --- /dev/null +++ b/MIBS/FRAME-RELAY-DTE-MIB @@ -0,0 +1,1084 @@ + FRAME-RELAY-DTE-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Counter32, + Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI + TEXTUAL-CONVENTION, RowStatus, TimeStamp FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP, + NOTIFICATION-GROUP FROM SNMPv2-CONF + transmission FROM RFC1213-MIB + InterfaceIndex FROM IF-MIB; + + -- Frame Relay DTE MIB + + frameRelayDTE MODULE-IDENTITY + LAST-UPDATED "9705010229Z" -- Thu May 1 02:29:46 PDT 1997 + ORGANIZATION "IETF IPLPDN Working Group" + CONTACT-INFO + " Caralyn Brown + Postal: Cadia Networks, Inc. + 1 Corporate Drive + Andover, Massachusetts 01810 + Tel: +1 508 689 2400 x133 + E-Mail: cbrown@cadia.com + + Fred Baker + Postal: Cisco Systems + 519 Lado Drive + Santa Barbara, California 93111 + Tel: +1 408 526 425 + E-Mail: fred@cisco.com" + DESCRIPTION + "The MIB module to describe the use of a Frame Relay + interface by a DTE." + REVISION "9705010229Z" -- Thu May 1 02:29:46 PDT 1997 + DESCRIPTION + "Converted from SMIv1 to SMIv2. (Thus, indices are + read-only rather than being not-accessible.) Added + objects and made clarifications based on implementation + experience." + + REVISION "9204010000Z" + DESCRIPTION + "Published as RFC 1315, the initial version of this MIB + module." + ::= { transmission 32 } + + + -- + -- the range of a Data Link Connection Identifier + -- + DLCI ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The range of DLCI values. Note that this varies by + interface configuration; normally, interfaces may use + 0..1023, but may be configured to use ranges as large + as 0..2^23." + SYNTAX Integer32(0..8388607) + + + + -- + + -- Data Link Connection Management Interface + + -- The variables that configure the DLC Management Interface. + + frDlcmiTable OBJECT-TYPE + SYNTAX SEQUENCE OF FrDlcmiEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The Parameters for the Data Link Connection Management + Interface for the frame relay service on this + interface." + REFERENCE + "American National Standard T1.617-1991, Annex D" + ::= { frameRelayDTE 1 } + + frDlcmiEntry OBJECT-TYPE + SYNTAX FrDlcmiEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The Parameters for a particular Data Link Connection + Management Interface." + INDEX { frDlcmiIfIndex } + ::= { frDlcmiTable 1 } + + + + + + FrDlcmiEntry ::= + SEQUENCE { + frDlcmiIfIndex InterfaceIndex, + frDlcmiState INTEGER, + frDlcmiAddress INTEGER, + frDlcmiAddressLen INTEGER, + frDlcmiPollingInterval Integer32, + frDlcmiFullEnquiryInterval Integer32, + frDlcmiErrorThreshold Integer32, + frDlcmiMonitoredEvents Integer32, + frDlcmiMaxSupportedVCs DLCI, + frDlcmiMulticast INTEGER, + frDlcmiStatus INTEGER, + frDlcmiRowStatus RowStatus + } + + + frDlcmiIfIndex OBJECT-TYPE + + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ifIndex value of the corresponding ifEntry." + ::= { frDlcmiEntry 1 } + + + frDlcmiState OBJECT-TYPE + SYNTAX INTEGER { + noLmiConfigured (1), + lmiRev1 (2), + ansiT1617D (3), -- ANSI T1.617 Annex D + ansiT1617B (4), -- ANSI T1.617 Annex B + itut933A (5), -- CCITT Q933 Annex A + ansiT1617D1994 (6) -- ANSI T1.617a-1994 Annex D + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable states which Data Link Connection + Management scheme is active (and by implication, what + DLCI it uses) on the Frame Relay interface." + REFERENCE + "American National Standard T1.617-1991, American + National Standard T1.617a-1994, ITU-T Recommendation + Q.933 (03/93)." + + ::= { frDlcmiEntry 2 } + + + frDlcmiAddress OBJECT-TYPE + SYNTAX INTEGER { + q921 (1), -- 13 bit DLCI + q922March90 (2), -- 11 bit DLCI + q922November90 (3), -- 10 bit DLCI + q922 (4) -- Final Standard + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable states which address format is in use on + the Frame Relay interface." + ::= { frDlcmiEntry 3 } + + + frDlcmiAddressLen OBJECT-TYPE + SYNTAX INTEGER { + twoOctets (2), + threeOctets (3), + fourOctets (4) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable states the address length in octets. In + the case of Q922 format, the length indicates the + entire length of the address including the control + portion." + ::= { frDlcmiEntry 4 } + + + frDlcmiPollingInterval OBJECT-TYPE + SYNTAX Integer32 (5..30) + UNITS "seconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This is the number of seconds between successive + status enquiry messages." + REFERENCE + "American National Standard T1.617-1991, Section D.7 + Timer T391." + DEFVAL { 10 } + ::= { frDlcmiEntry 5 } + + + frDlcmiFullEnquiryInterval OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Number of status enquiry intervals that pass before + issuance of a full status enquiry message." + REFERENCE + "American National Standard T1.617-1991, Section D.7 + Counter N391." + DEFVAL { 6 } + ::= { frDlcmiEntry 6 } + + + frDlcmiErrorThreshold OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This is the maximum number of unanswered Status + Enquiries the equipment shall accept before declaring + the interface down." + REFERENCE + "American National Standard T1.617-1991, Section D.5.1 + Counter N392." + DEFVAL { 3 } + ::= { frDlcmiEntry 7 } + + + frDlcmiMonitoredEvents OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This is the number of status polling intervals over + which the error threshold is counted. For example, if + within 'MonitoredEvents' number of events the station + receives 'ErrorThreshold' number of errors, the + interface is marked as down." + REFERENCE + "American National Standard T1.617-1991, Section D.5.2 + Counter N393." + DEFVAL { 4 } + ::= { frDlcmiEntry 8 } + + + + + frDlcmiMaxSupportedVCs OBJECT-TYPE + SYNTAX DLCI + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The maximum number of Virtual Circuits allowed for + this interface. Usually dictated by the Frame Relay + network. + + In response to a SET, if a value less than zero or + higher than the agent's maximal capability is + configured, the agent should respond badValue" + ::= { frDlcmiEntry 9 } + + + frDlcmiMulticast OBJECT-TYPE + SYNTAX INTEGER { + nonBroadcast (1), + broadcast (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This indicates whether the Frame Relay interface is + using a multicast service." + ::= { frDlcmiEntry 10 } + + + + frDlcmiStatus OBJECT-TYPE + SYNTAX INTEGER { + running (1), -- init complete, system running + fault (2), -- error threshold exceeded + initializing (3) -- system start up + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates the status of the Frame Relay interface + as determined by the performance of the dlcmi. If no + dlcmi is running, the Frame Relay interface will stay + in the running state indefinitely." + ::= { frDlcmiEntry 11 } + + + + + + frDlcmiRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SNMP Version 2 Row Status Variable. Writable objects + in the table may be written in any RowStatus state." + ::= { frDlcmiEntry 12 } + + + -- + -- A Frame Relay service is a multiplexing service. Data + -- Link Connection Identifiers enumerate virtual circuits + -- (permanent or dynamic) which are layered onto the underlying + -- circuit, represented by ifEntry. Therefore, each of the entries + -- in the Standard MIB's Interface Table with an IfType of + -- Frame Relay represents a Q.922 interface. Zero or more + -- virtual circuits are layered onto this interface and provide + -- interconnection with various remote destinations. + -- Each such virtual circuit is represented by an entry in the + -- circuit table. The management virtual circuit (i.e. DLCI 0) + -- is a virtual circuit by this definition and will be represented + -- with an entry in the circuit table. + + -- Circuit Table + + -- The table describing the use of the DLCIs attached to + -- each Frame Relay Interface. + + frCircuitTable OBJECT-TYPE + SYNTAX SEQUENCE OF FrCircuitEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information about specific Data + Link Connections (DLC) or virtual circuits." + ::= { frameRelayDTE 2 } + + + + + + + + + + + + frCircuitEntry OBJECT-TYPE + SYNTAX FrCircuitEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information regarding a single Data Link + Connection. Discontinuities in the counters contained + in this table are indicated by the value in + frCircuitCreationTime." + INDEX { frCircuitIfIndex, frCircuitDlci } + ::= { frCircuitTable 1 } + + + FrCircuitEntry ::= + SEQUENCE { + frCircuitIfIndex InterfaceIndex, + frCircuitDlci DLCI, + frCircuitState INTEGER, + frCircuitReceivedFECNs Counter32, + frCircuitReceivedBECNs Counter32, + frCircuitSentFrames Counter32, + frCircuitSentOctets Counter32, + frCircuitReceivedFrames Counter32, + frCircuitReceivedOctets Counter32, + frCircuitCreationTime TimeStamp, + frCircuitLastTimeChange TimeStamp, + frCircuitCommittedBurst Integer32, + frCircuitExcessBurst Integer32, + frCircuitThroughput Integer32, + frCircuitMulticast INTEGER, + frCircuitType INTEGER, + frCircuitDiscards Counter32, + frCircuitReceivedDEs Counter32, + frCircuitSentDEs Counter32, + frCircuitLogicalIfIndex InterfaceIndex, + frCircuitRowStatus RowStatus + } + + + frCircuitIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ifIndex Value of the ifEntry this virtual circuit + is layered onto." + ::= { frCircuitEntry 1 } + + + frCircuitDlci OBJECT-TYPE + SYNTAX DLCI + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Data Link Connection Identifier for this virtual + circuit." + REFERENCE + "American National Standard T1.618-1991, Section 3.3.6" + ::= { frCircuitEntry 2 } + + + frCircuitState OBJECT-TYPE + SYNTAX INTEGER { + + invalid (1), + active (2), + inactive (3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Indicates whether the particular virtual circuit is + operational. In the absence of a Data Link Connection + Management Interface, virtual circuit entries (rows) + may be created by setting virtual circuit state to + 'active', or deleted by changing Circuit state to + 'invalid'. + + Whether or not the row actually disappears is left to + the implementation, so this object may actually read as + 'invalid' for some arbitrary length of time. It is + also legal to set the state of a virtual circuit to + 'inactive' to temporarily disable a given circuit. + + The use of 'invalid' is deprecated in this SNMP Version + 2 MIB, in favor of frCircuitRowStatus." + DEFVAL { active } + ::= { frCircuitEntry 3 } + + + + + + + + + frCircuitReceivedFECNs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of frames received from the network indicating + forward congestion since the virtual circuit was + created. This occurs when the remote DTE sets the FECN + flag, or when a switch in the network enqueues the + frame to a trunk whose transmission queue is + congested." + REFERENCE + "American National Standard T1.618-1991, Section 3.3.3" + ::= { frCircuitEntry 4 } + + + frCircuitReceivedBECNs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + + + STATUS current + DESCRIPTION + "Number of frames received from the network indicating + backward congestion since the virtual circuit was + created. This occurs when the remote DTE sets the BECN + flag, or when a switch in the network receives the + frame from a trunk whose transmission queue is + congested." + REFERENCE + "American National Standard T1.618-1991, Section 3.3.4" + ::= { frCircuitEntry 5 } + + + frCircuitSentFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frames sent from this virtual circuit + since it was created." + ::= { frCircuitEntry 6 } + + + frCircuitSentOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of octets sent from this virtual circuit + since it was created. Octets counted are the full + frame relay header and the payload, but do not include + the flag characters or CRC." + ::= { frCircuitEntry 7 } + + + frCircuitReceivedFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of frames received over this virtual circuit + since it was created." + ::= { frCircuitEntry 8 } + + + frCircuitReceivedOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of octets received over this virtual circuit + since it was created. Octets counted include the full + frame relay header, but do not include the flag + characters or the CRC." + ::= { frCircuitEntry 9 } + + + frCircuitCreationTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the virtual circuit was + created, whether by the Data Link Connection Management + Interface or by a SetRequest." + ::= { frCircuitEntry 10 } + + + + + + + + + + frCircuitLastTimeChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when last there was a change in + the virtual circuit state" + ::= { frCircuitEntry 11 } + + + frCircuitCommittedBurst OBJECT-TYPE + SYNTAX Integer32(0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable indicates the maximum amount of data, in + bits, that the network agrees to transfer under normal + conditions, during the measurement interval." + REFERENCE + "American National Standard T1.617-1991, Section + 6.5.19" + DEFVAL { 0 } -- the default indicates no commitment + ::= { frCircuitEntry 12 } + + + frCircuitExcessBurst OBJECT-TYPE + SYNTAX Integer32(0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable indicates the maximum amount of + uncommitted data bits that the network will attempt to + deliver over the measurement interval. + + By default, if not configured when creating the entry, + the Excess Information Burst Size is set to the value + of ifSpeed." + REFERENCE + "American National Standard T1.617-1991, Section + 6.5.19" + ::= { frCircuitEntry 13 } + + + frCircuitThroughput OBJECT-TYPE + SYNTAX Integer32(0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Throughput is the average number of 'Frame Relay + Information Field' bits transferred per second across a + user network interface in one direction, measured over + the measurement interval. + + If the configured committed burst rate and throughput + are both non-zero, the measurement interval, T, is + T=frCircuitCommittedBurst/frCircuitThroughput. + + If the configured committed burst rate and throughput + are both zero, the measurement interval, T, is + T=frCircuitExcessBurst/ifSpeed." + REFERENCE + "American National Standard T1.617-1991, Section + 6.5.19" + DEFVAL {0} -- the default value of Throughput is + -- "no commitment". + ::= { frCircuitEntry 14 } + + + frCircuitMulticast OBJECT-TYPE + SYNTAX INTEGER { + unicast (1), + oneWay (2), + twoWay (3), + nWay (4) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This indicates whether this VC is used as a unicast VC + (i.e. not multicast) or the type of multicast service + subscribed to" + REFERENCE + "Frame Relay PVC Multicast Service and Protocol + Description Implementation: FRF.7 Frame Relay Forum + Technical Committe October 21, 1994" + DEFVAL {unicast} + -- the default value of frCircuitMulticast is + -- "unicast" (not a multicast VC). + ::= { frCircuitEntry 15 } + + + frCircuitType OBJECT-TYPE + SYNTAX INTEGER { + static (1), + dynamic (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indication of whether the VC was manually created + (static), or dynamically created (dynamic) via the data + link control management interface." + ::= { frCircuitEntry 16 } + + + frCircuitDiscards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of inbound frames dropped because of format + errors, or because the VC is inactive." + ::= { frCircuitEntry 17 } + + + frCircuitReceivedDEs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of frames received from the network indicating + that they were eligible for discard since the virtual + circuit was created. This occurs when the remote DTE + sets the DE flag, or when in remote DTE's switch + detects that the frame was received as Excess Burst + data." + REFERENCE + "American National Standard T1.618-1991, Section 3.3.4" + ::= { frCircuitEntry 18 } + + + frCircuitSentDEs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of frames sent to the network indicating that + they were eligible for discard since the virtual + circuit was created. This occurs when the local DTE + sets the DE flag, indicating that during Network + congestion situations those frames should be discarded + in preference of other frames sent without the DE bit + set." + REFERENCE + "American National Standard T1.618-1991, Section + 3.3.4" + ::= { frCircuitEntry 19 } + + frCircuitLogicalIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Normally the same value as frDlcmiIfIndex, but + different when an implementation associates a virtual + ifEntry with a DLC or set of DLCs in order to associate + higher layer objects such as the ipAddrEntry with a + subset of the virtual circuits on a Frame Relay + interface. The type of such ifEntries is defined by the + higher layer object; for example, if PPP/Frame Relay is + implemented, the ifType of this ifEntry would be PPP. + If it is not so defined, as would be the case with an + ipAddrEntry, it should be of type Other." + ::= { frCircuitEntry 20 } + + frCircuitRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to create a new row or modify or + destroy an existing row in the manner described in the + definition of the RowStatus textual convention. + Writable objects in the table may be written in any + RowStatus state." + ::= { frCircuitEntry 21 } + + + -- + -- Error Table + + -- The table describing errors encountered on each Frame + -- Relay Interface. + + frErrTable OBJECT-TYPE + SYNTAX SEQUENCE OF FrErrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information about Errors on the + Frame Relay interface. Discontinuities in the counters + contained in this table are the same as apply to the + ifEntry associated with the Interface." + ::= { frameRelayDTE 3 } + + frErrEntry OBJECT-TYPE + SYNTAX FrErrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The error information for a single frame relay + interface." + INDEX { frErrIfIndex } + ::= { frErrTable 1 } + + + FrErrEntry ::= + SEQUENCE { + frErrIfIndex InterfaceIndex, + frErrType INTEGER, + frErrData OCTET STRING, + frErrTime TimeStamp, + frErrFaults Counter32, + frErrFaultTime TimeStamp + } + + + frErrIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The ifIndex Value of the corresponding ifEntry." + ::= { frErrEntry 1 } + + + frErrType OBJECT-TYPE + SYNTAX INTEGER { + unknownError(1), + receiveShort(2), + receiveLong(3), + illegalAddress(4), + unknownAddress(5), + dlcmiProtoErr(6), + dlcmiUnknownIE(7), + dlcmiSequenceErr(8), + dlcmiUnknownRpt(9), + noErrorSinceReset(10) + } + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of error that was last seen on this interface: + + receiveShort: frame was not long enough to allow + demultiplexing - the address field was incomplete, + or for virtual circuits using Multiprotocol over + Frame Relay, the protocol identifier was missing + or incomplete. + + receiveLong: frame exceeded maximum length configured for this + interface. + + illegalAddress: address field did not match configured format. + + unknownAddress: frame received on a virtual circuit which was not + active or administratively disabled. + + dlcmiProtoErr: unspecified error occurred when attempting to + interpret link maintenance frame. + + dlcmiUnknownIE: link maintenance frame contained an Information + Element type which is not valid for the + configured link maintenance protocol. + + dlcmiSequenceErr: link maintenance frame contained a sequence + number other than the expected value. + + dlcmiUnknownRpt: link maintenance frame contained a Report Type + Information Element whose value was not valid + for the configured link maintenance protocol. + + noErrorSinceReset: no errors have been detected since the last + cold start or warm start." + ::= { frErrEntry 2 } + + + frErrData OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..1600)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An octet string containing as much of the error packet + as possible. As a minimum, it must contain the Q.922 + Address or as much as was delivered. It is desirable + to include all header and demultiplexing information." + ::= { frErrEntry 3 } + + + frErrTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at which the error was + detected." + ::= { frErrEntry 4 } + + + frErrFaults OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of times the interface has gone down since + it was initialized." + ::= { frErrEntry 5 } + + + frErrFaultTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time when the interface + was taken down due to excessive errors. Excessive + errors is defined as the time when a DLCMI exceeds the + frDlcmiErrorThreshold number of errors within + frDlcmiMonitoredEvents. See FrDlcmiEntry for further + details." + ::= { frErrEntry 6 } + + + -- + + -- Frame Relay Trap Control + + frameRelayTrapControl OBJECT IDENTIFIER ::= { frameRelayDTE 4 } + + -- the following highly unusual OID is as it is for compatibility + -- with RFC 1315, the SNMP V1 predecessor of this document. + frameRelayTraps OBJECT IDENTIFIER ::= { frameRelayDTE 0 } + + + + frTrapState OBJECT-TYPE + SYNTAX INTEGER { enabled(1), disabled(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable indicates whether the system produces + the frDLCIStatusChange trap." + DEFVAL { disabled } + ::= { frameRelayTrapControl 1 } + + frTrapMaxRate OBJECT-TYPE + SYNTAX Integer32 (0..3600000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable indicates the number of milliseconds + that must elapse between trap emissions. If events + occur more rapidly, the impementation may simply fail + to trap, or may queue traps until an appropriate time." + DEFVAL { 0 } -- no minimum elapsed period is specified + ::= { frameRelayTrapControl 2 } + + + + -- Data Link Connection Management Interface Related Traps + + frDLCIStatusChange NOTIFICATION-TYPE + OBJECTS { frCircuitState } + STATUS current + + + DESCRIPTION + "This trap indicates that the indicated Virtual Circuit + has changed state. It has either been created or + invalidated, or has toggled between the active and + inactive states. If, however, the reason for the state + change is due to the DLCMI going down, per-DLCI traps + should not be generated." + ::= { frameRelayTraps 1 } + -- conformance information + + frConformance OBJECT IDENTIFIER ::= { frameRelayDTE 6 } + + frGroups OBJECT IDENTIFIER ::= { frConformance 1 } + frCompliances OBJECT IDENTIFIER ::= { frConformance 2 } + + -- compliance statements + + frCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement " + MODULE -- this module + MANDATORY-GROUPS { frPortGroup, frCircuitGroup } + + GROUP frErrGroup + DESCRIPTION + "This optional group is used for debugging Frame Relay + Systems." + + GROUP frTrapGroup + DESCRIPTION + "This optional group is used for the management of + asynchronous notifications by Frame Relay Systems." + + GROUP frNotificationGroup + DESCRIPTION + "This optional group defines the asynchronous + notifications generated by Frame Relay Systems." + + OBJECT frDlcmiRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Row creation is not required for the frDlcmiTable." + + OBJECT frCircuitRowStatus + + MIN-ACCESS read-only + DESCRIPTION + "Row creation is not required for the frCircuitTable." + + ::= { frCompliances 1 } + + frCompliance0 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for objects and the trap + defined in RFC 1315." + MODULE -- this module + MANDATORY-GROUPS { frPortGroup0, frCircuitGroup0 } + + GROUP frErrGroup0 + DESCRIPTION + "This optional group is used for debugging Frame Relay + Systems." + + GROUP frTrapGroup0 + DESCRIPTION + "This optional group is used for the management of + asynchronous notifications by Frame Relay Systems." + + GROUP frNotificationGroup + DESCRIPTION + "This optional group defines the asynchronous + notifications generated by Frame Relay Systems." + + ::= { frCompliances 2 } + + -- units of conformance + + frPortGroup OBJECT-GROUP + OBJECTS { + frDlcmiIfIndex, frDlcmiState, frDlcmiAddress, + frDlcmiAddressLen, frDlcmiPollingInterval, + frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold, + frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs, + frDlcmiMulticast, frDlcmiStatus, frDlcmiRowStatus + } + STATUS current + DESCRIPTION + "The objects necessary to control the Link Management + Interface for a Frame Relay Interface as well as + maintain the error statistics on this interface." + ::= { frGroups 1 } + + frCircuitGroup OBJECT-GROUP + OBJECTS { + frCircuitIfIndex, frCircuitDlci, frCircuitState, + frCircuitReceivedFECNs, frCircuitReceivedBECNs, + frCircuitSentFrames, frCircuitSentOctets, + frCircuitReceivedFrames, frCircuitReceivedOctets, + frCircuitCreationTime, frCircuitLastTimeChange, + frCircuitCommittedBurst, frCircuitExcessBurst, + frCircuitThroughput, frCircuitMulticast, + frCircuitType, frCircuitDiscards, + frCircuitReceivedDEs, frCircuitSentDEs, + frCircuitLogicalIfIndex, frCircuitRowStatus + } + STATUS current + DESCRIPTION + "The objects necessary to control the Virtual Circuits + layered onto a Frame Relay Interface." + ::= { frGroups 2 } + + frTrapGroup OBJECT-GROUP + OBJECTS { frTrapState, frTrapMaxRate } + STATUS current + DESCRIPTION + "The objects necessary to control a Frame Relay + Interface's notification messages." + ::= { frGroups 3 } + + frErrGroup OBJECT-GROUP + OBJECTS { + frErrIfIndex, frErrType, frErrData, frErrTime, + frErrFaults, frErrFaultTime + } + STATUS current + DESCRIPTION + "Objects designed to assist in debugging Frame Relay + Interfaces." + ::= { frGroups 4 } + + frNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { frDLCIStatusChange } + STATUS current + DESCRIPTION + "Traps which may be used to enhance event driven + management of the interface." + ::= { frGroups 5 } + + frPortGroup0 OBJECT-GROUP + OBJECTS { + frDlcmiIfIndex, frDlcmiState, frDlcmiAddress, + frDlcmiAddressLen, frDlcmiPollingInterval, + frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold, + frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs, + frDlcmiMulticast + } + STATUS current + DESCRIPTION + "The objects necessary to control the Link Management + Interface for a Frame Relay Interface as well as + maintain the error statistics on this interface from + RFC 1315." + ::= { frGroups 6 } + + frCircuitGroup0 OBJECT-GROUP + OBJECTS { + frCircuitIfIndex, frCircuitDlci, frCircuitState, + frCircuitReceivedFECNs, frCircuitReceivedBECNs, + frCircuitSentFrames, frCircuitSentOctets, + frCircuitReceivedFrames, frCircuitReceivedOctets, + frCircuitCreationTime, frCircuitLastTimeChange, + frCircuitCommittedBurst, frCircuitExcessBurst, + frCircuitThroughput + } + STATUS current + DESCRIPTION + "The objects necessary to control the Virtual Circuits + layered onto a Frame Relay Interface from RFC 1315." + ::= { frGroups 7 } + + frErrGroup0 OBJECT-GROUP + OBJECTS { + frErrIfIndex, frErrType, frErrData, frErrTime + } + STATUS current + DESCRIPTION + "Objects designed to assist in debugging Frame Relay + Interfaces from RFC 1315." + ::= { frGroups 8 } + + + frTrapGroup0 OBJECT-GROUP + OBJECTS { frTrapState } + STATUS current + DESCRIPTION + "The objects necessary to control a Frame Relay + Interface's notification messages from RFC 1315." + ::= { frGroups 9 } + + END |