From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB | 2769 ++++++++++++++++++++++++++++ 1 file changed, 2769 insertions(+) create mode 100644 MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB (limited to 'MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB') diff --git a/MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB b/MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB new file mode 100644 index 0000000..f41c452 --- /dev/null +++ b/MIBS/wut/WebGraph-Thermo-Hygrometer-US-MIB @@ -0,0 +1,2769 @@ +WebGraph-Thermo-Hygrometer-US-MIB DEFINITIONS ::= BEGIN +---------------------------------------------------------------- +-- Revison: 1.39 +---------------------------------------------------------------- +-- 28.06.2018 New: +-- syntax error corrected +---------------------------------------------------------------- + +-- 12.12.2017 New: +-- wtWebGraphThermoHygroMQTTLastWillEnable +-- wtWebGraphThermoHygroMQTTLastWillTopic +-- wtWebGraphThermoHygroMQTTLastWillMsg +-- wtWebGraphThermoHygroMQTTLastWillQoS +-- wtWebGraphThermoHygroMQTTLastWillRetain +-- wtWebGraphThermoHygroMQTTLastWillConnectEnable +-- wtWebGraphThermoHygroMQTTLastWillConnectMsg +---------------------------------------------------------------- +-- Revison: 1.37 +---------------------------------------------------------------- +-- 07.09.2017 New: wtWebioAnxGraphAlarmManagerPort +-- wtWebioAnxGraphAlarmMQTT_QoS +-- wtWebioAnxGraphAlarmMQTT_Retain +---------------------------------------------------------------- +-- Revison: 1.36 +---------------------------------------------------------------- +-- 09.03.2017 New: wtWebGraphThermoHygroAlarmSensorLostSelection +-- wtWebGraphThermoHygroAlarmLimitWindow +---------------------------------------------------------------- +-- Revison: 1.35 +---------------------------------------------------------------- +-- 09.11.2016 New: wtWebGraphThermoHygroMQTT group +-- HTTP Request, MQTT Alarm, REST +---------------------------------------------------------------- +-- Revison: 1.34 +---------------------------------------------------------------- +-- 15.07.2015 Changes for new Navigation (__JB__) +---------------------------------------------------------------- +-- Revison: 1.33 +---------------------------------------------------------------- +-- 28.05.14 New Language Select +-- +---------------------------------------------------------------- +-- Revison: 1.32 +---------------------------------------------------------------- +-- 11.12.13 Initial Setup +-- + + + + IMPORTS + + OBJECT-TYPE FROM RFC-1212 + TRAP-TYPE FROM RFC-1215 + DisplayString, PhysAddress FROM RFC1213-MIB + enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; + + +-- IpAddress ::= +-- [APPLICATION 0] +-- IMPLICIT OCTET STRING (SIZE (4)) +-- Counter ::= +-- [APPLICATION 1] +-- IMPLICIT INTEGER (0..4294967295) +-- Gauge ::= +-- [APPLICATION 2] +-- IMPLICIT INTEGER (0..4294967295) +-- TimeTicks ::= +-- [APPLICATION 3] +-- IMPLICIT INTEGER (0..4294967295) + + +-- DisplayString ::= OCTET STRING +-- PhysAddress ::= OCTET STRING + +-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } +-- privat OBJECT IDENTIFIER ::= { internet 4 } +-- enterprises OBJECT IDENTIFIER ::= { privat 1 } + + + +-- Wiesemann & Theis Com-Server MIB + + wut OBJECT IDENTIFIER ::= { enterprises 5040 } + wtComServer OBJECT IDENTIFIER ::= { wut 1 } + wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } + +-- wtWebGraph Tree + + wtWebGraphThermoHygro OBJECT IDENTIFIER ::= { wtWebio 42 } + +-- wtWebGraphThermoHygro Tree + + wtWebGraphThermoHygroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 1 } + wtWebGraphThermoHygroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 2 } + wtWebGraphThermoHygroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 3 } + wtWebGraphThermoHygroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 4 } + +-- wtWebGraphThermoHygroConfig Tree + + wtWebGraphThermoHygroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 1 } + wtWebGraphThermoHygroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 2 } + wtWebGraphThermoHygroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 3 } + +-- wtWebGraphThermoHygroDevice Tree + + wtWebGraphThermoHygroText OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 1 } + wtWebGraphThermoHygroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 2 } + wtWebGraphThermoHygroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 3 } + wtWebGraphThermoHygroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 4 } + wtWebGraphThermoHygroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 5 } + wtWebGraphThermoHygroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 6 } + +-- wtWebGraphThermoHygroTimeDate Tree + + wtWebGraphThermoHygroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 1 } + wtWebGraphThermoHygroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 2 } + wtWebGraphThermoHygroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 3 } + +-- wtWebGraphThermoHygroBasic Tree + + wtWebGraphThermoHygroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 1 } + wtWebGraphThermoHygroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 2 } + wtWebGraphThermoHygroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 3 } + wtWebGraphThermoHygroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 4 } + wtWebGraphThermoHygroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 5 } + wtWebGraphThermoHygroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 6 } + wtWebGraphThermoHygroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 7 } + wtWebGraphThermoHygroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 8 } + wtWebGraphThermoHygroLanguage OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 9 } + wtWebGraphThermoHygroMQTT OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 12 } + wtWebGraphThermoHygroREST OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 13 } + + +-- wtWebGraphThermoHygroGraphics Tree + + wtWebGraphThermoHygroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 1 } + wtWebGraphThermoHygroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 2 } + wtWebGraphThermoHygroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 3 } + +-- wtWebGraphThermoHygroTemp Group +------------------------ + +wtWebGraphThermoHygroSensors OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of sensors" + ::= { wtWebGraphThermoHygroTemp 1 } + +-- Interface Table + +wtWebGraphThermoHygroSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of sensors." + ::= { wtWebGraphThermoHygroTemp 2 } + +wtWebGraphThermoHygroSensorEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of sensor numbers." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroSensorTable 1 } + +WtWebGraphThermoHygroSensorEntry ::= SEQUENCE { + wtWebGraphThermoHygroSensorNo INTEGER +} + +wtWebGraphThermoHygroSensorNo OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Sensor number." + ::= { wtWebGraphThermoHygroSensorEntry 1 } + + +-- wtWebGraphThermoHygroTempValue Table + +wtWebGraphThermoHygroTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of measurement values corresponding to the channel numbers." + ::= { wtWebGraphThermoHygroTemp 3 } + +wtWebGraphThermoHygroTempValueEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Measurement values of the sensors." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroTempValueTable 1 } + +WtWebGraphThermoHygroTempValueEntry ::= SEQUENCE{ + wtWebGraphThermoHygroTempValue OCTET STRING +} + +wtWebGraphThermoHygroTempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Measurement value of the sensor, ASCII, 5 characters in length." + ::= { wtWebGraphThermoHygroTempValueEntry 1 } + +-- wtWebGraphThermoHygroBinaryTempValue Table + +wtWebGraphThermoHygroBinaryTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroBinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of binary measurement values corresponding to the channel numbers." + ::= { wtWebGraphThermoHygroTemp 4 } + +wtWebGraphThermoHygroBinaryTempValueEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroBinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binary measurement values of the sensors." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroBinaryTempValueTable 1 } + +WtWebGraphThermoHygroBinaryTempValueEntry ::= SEQUENCE{ + wtWebGraphThermoHygroBinaryTempValue INTEGER +} + +wtWebGraphThermoHygroBinaryTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, + signed number, 0x4FFF6 indicates an + invalid measured value." + ::= { wtWebGraphThermoHygroBinaryTempValueEntry 1 } + +-- wtWebGraphThermoHygroTempValuePkt Table + +wtWebGraphThermoHygroTempValuePktTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValuePktEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of measurement values corresponding to the channel numbers." + ::= { wtWebGraphThermoHygroTemp 8 } + +wtWebGraphThermoHygroTempValuePktEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroTempValuePktEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Measurement values of the sensors." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroTempValuePktTable 1 } + +WtWebGraphThermoHygroTempValuePktEntry ::= SEQUENCE{ + wtWebGraphThermoHygroTempValuePkt OCTET STRING +} + +wtWebGraphThermoHygroTempValuePkt OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point." + ::= { wtWebGraphThermoHygroTempValuePktEntry 1 } + +-- wtWebGraphThermoHygroSessCntrl Group +-------------------------------- + +wtWebGraphThermoHygroSessCntrlPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Entering this password opens a session which is ended by writing a 1 to + wtWebGraphThermoHygroSessCntrlLogout. When read this variable provides a string of + length zero." + ::= { wtWebGraphThermoHygroSessCntrl 1 } + +wtWebGraphThermoHygroSessCntrlConfigMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroSessCntrl-NoSession(0), + wtWebGraphThermoHygroSessCntrl-Session(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "When the device is in SNMP configuration mode, the value 1 is + returned, otherwise 0. If the read value is 0 even though the + password was written, the device is already in config mode and the + variables can only be read." + ::= { wtWebGraphThermoHygroSessCntrl 2 } + +wtWebGraphThermoHygroSessCntrlLogout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If the device is in configuration mode and the session was opened by + this SNMP Manager, writing a 1 to this variable will end the session + and all parameters are stored. + Writing a 2 discards all entries again. + When read this variable provides the value 0." + ::= { wtWebGraphThermoHygroSessCntrl 3 } + +wtWebGraphThermoHygroSessCntrlAdminPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This password protects access to the variables with administrator rights. + It can only be changed by the administrator. If no password was assigned, + the valid password is public." + ::= { wtWebGraphThermoHygroSessCntrl 4 } + +wtWebGraphThermoHygroSessCntrlConfigPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This password protects access to the variables with configurator rights. It can + be changed by the administrator and by the configurator. If no password was assigned, + the valid password is public. When read this variable provides a null-pointer." + ::= { wtWebGraphThermoHygroSessCntrl 5 } + + +-- wtWebGraphThermoHygroText Group +------------------------ + +wtWebGraphThermoHygroDeviceName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name of the Webio, which is user definable." + ::= { wtWebGraphThermoHygroText 1 } + +wtWebGraphThermoHygroDeviceText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Description of the Webio, which is user definable." + ::= { wtWebGraphThermoHygroText 2 } + +wtWebGraphThermoHygroDeviceLocation OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Description of the location of the Webio, which is user definable." + ::= { wtWebGraphThermoHygroText 3 } + +wtWebGraphThermoHygroDeviceContact OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Contact address of the system operator of the Webio, which is user definable." + ::= { wtWebGraphThermoHygroText 4 } + +-- wtWebGraphThermoHygroTimeZone Group +---------------------------- + +wtWebGraphThermoHygroTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset hours for the time zone (winter time) with respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 1 } + +wtWebGraphThermoHygroTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset minutes for the time zone (winter time) with respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 2 } + +wtWebGraphThermoHygroTzEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Apply Timezone" + ::= { wtWebGraphThermoHygroTimeZone 3 } + +wtWebGraphThermoHygroStTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset hours of the time zone (summer time) with respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 4 } + +wtWebGraphThermoHygroStTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset minutes of the time zone (summer time) with respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 5 } + +wtWebGraphThermoHygroStTzEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Apply Summertime" + ::= { wtWebGraphThermoHygroTimeZone 6 } + +wtWebGraphThermoHygroStTzStartMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStartMonth-January(1), + wtWebGraphThermoHygroStartMonth-February(2), + wtWebGraphThermoHygroStartMonth-March(3), + wtWebGraphThermoHygroStartMonth-April(4), + wtWebGraphThermoHygroStartMonth-May(5), + wtWebGraphThermoHygroStartMonth-June(6), + wtWebGraphThermoHygroStartMonth-July(7), + wtWebGraphThermoHygroStartMonth-August(8), + wtWebGraphThermoHygroStartMonth-September(9), + wtWebGraphThermoHygroStartMonth-October(10), + wtWebGraphThermoHygroStartMonth-November(11), + wtWebGraphThermoHygroStartMonth-December(12) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Month in which the change is made from winter time to summer time." + ::= { wtWebGraphThermoHygroTimeZone 7 } + +wtWebGraphThermoHygroStTzStartMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStartMode-first(1), + wtWebGraphThermoHygroStartMode-second(2), + wtWebGraphThermoHygroStartMode-third(3), + wtWebGraphThermoHygroStartMode-fourth(4), + wtWebGraphThermoHygroStartMode-last(5) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Mode of the day of the week for which the change is made from winter time to summer time." + ::= { wtWebGraphThermoHygroTimeZone 8 } + +wtWebGraphThermoHygroStTzStartWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStartWday-Sunday(1), + wtWebGraphThermoHygroStartWday-Monday(2), + wtWebGraphThermoHygroStartWday-Tuesday(3), + wtWebGraphThermoHygroStartWday-Thursday(4), + wtWebGraphThermoHygroStartWday-Wednesday(5), + wtWebGraphThermoHygroStartWday-Friday(6), + wtWebGraphThermoHygroStartWday-Saturday(7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Day of the week on which the change is made from winter time to summer time" + ::= { wtWebGraphThermoHygroTimeZone 9 } + +wtWebGraphThermoHygroStTzStartHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hour in which the time zone is changed from winter to summer time with + respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 10 } + +wtWebGraphThermoHygroStTzStartMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute in which the time zone is changed from winter to summer time with + respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 11 } + +wtWebGraphThermoHygroStTzStopMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStopMonth-January(1), + wtWebGraphThermoHygroStopMonth-February(2), + wtWebGraphThermoHygroStopMonth-March(3), + wtWebGraphThermoHygroStopMonth-April(4), + wtWebGraphThermoHygroStopMonth-May(5), + wtWebGraphThermoHygroStopMonth-June(6), + wtWebGraphThermoHygroStopMonth-July(7), + wtWebGraphThermoHygroStopMonth-August(8), + wtWebGraphThermoHygroStopMonth-September(9), + wtWebGraphThermoHygroStopMonth-October(10), + wtWebGraphThermoHygroStopMonth-November(11), + wtWebGraphThermoHygroStopMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Month in which the change is made from summer time to winter time." + ::= { wtWebGraphThermoHygroTimeZone 12 } + +wtWebGraphThermoHygroStTzStopMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStopMode-first(1), + wtWebGraphThermoHygroStopMode-second(2), + wtWebGraphThermoHygroStopMode-third(3), + wtWebGraphThermoHygroStopMode-fourth(4), + wtWebGraphThermoHygroStopMode-last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Mode of the week day on which the change is made from summer time to winter time." + ::= { wtWebGraphThermoHygroTimeZone 13 } + +wtWebGraphThermoHygroStTzStopWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroStopWday-Sunday(1), + wtWebGraphThermoHygroStopWday-Monday(2), + wtWebGraphThermoHygroStopWday-Tuesday(3), + wtWebGraphThermoHygroStopWday-Thursday(4), + wtWebGraphThermoHygroStopWday-Wednesday(5), + wtWebGraphThermoHygroStopWday-Friday(6), + wtWebGraphThermoHygroStopWday-Saturday(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Day of the week on which the change is made from summer time to winter time." + ::= { wtWebGraphThermoHygroTimeZone 14 } + +wtWebGraphThermoHygroStTzStopHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hour at which the time zone is changed from summer to winter time with + respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 15 } + +wtWebGraphThermoHygroStTzStopMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute at which the time zone is changed from summer to winter time with + respect to UTC." + ::= { wtWebGraphThermoHygroTimeZone 16 } + +-- wtWebGraphThermoHygroTimeServer Group +---------------------------- + +wtWebGraphThermoHygroTimeServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address or name of the 1st time server in ASCII" + ::= { wtWebGraphThermoHygroTimeServer 1 } + +wtWebGraphThermoHygroTimeServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address or name of the 2nd time server in ASCII" + ::= { wtWebGraphThermoHygroTimeServer 2 } + +wtWebGraphThermoHygroTsEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Apply Time Server" + ::= { wtWebGraphThermoHygroTimeServer 3 } + +wtWebGraphThermoHygroTsSyncTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Daily synchronisation time with the time server (hour: 0-23)." + ::= { wtWebGraphThermoHygroTimeServer 4 } + +-- wtWebGraphThermoHygroDeviceClock Group +---------------------------- + +wtWebGraphThermoHygroClockHrs OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Clock hours taking into account the time zone settings." + ::= { wtWebGraphThermoHygroDeviceClock 1 } + +wtWebGraphThermoHygroClockMin OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Clock minutes taking into account the time zone settings." + ::= { wtWebGraphThermoHygroDeviceClock 2 } + +wtWebGraphThermoHygroClockDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Date: Day of the month, taking into account the time zone settings." + ::= { wtWebGraphThermoHygroDeviceClock 3 } + +wtWebGraphThermoHygroClockMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroClockMonth-January(1), + wtWebGraphThermoHygroClockMonth-February(2), + wtWebGraphThermoHygroClockMonth-March(3), + wtWebGraphThermoHygroClockMonth-April(4), + wtWebGraphThermoHygroClockMonth-May(5), + wtWebGraphThermoHygroClockMonth-June(6), + wtWebGraphThermoHygroClockMonth-July(7), + wtWebGraphThermoHygroClockMonth-August(8), + wtWebGraphThermoHygroClockMonth-September(9), + wtWebGraphThermoHygroClockMonth-October(10), + wtWebGraphThermoHygroClockMonth-November(11), + wtWebGraphThermoHygroClockMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Date: Month, taking into account the time zone settings." + ::= { wtWebGraphThermoHygroDeviceClock 4 } + +wtWebGraphThermoHygroClockYear OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Date: Year, taking into account the time zone settings." + ::= { wtWebGraphThermoHygroDeviceClock 5 } + + +-- wtWebGraphThermoHygroNetwork Group +------------------------ + +wtWebGraphThermoHygroIpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address of the Webio" + ::= { wtWebGraphThermoHygroNetwork 1 } + +wtWebGraphThermoHygroSubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subnet mask of the Webio" + ::= { wtWebGraphThermoHygroNetwork 2 } + +wtWebGraphThermoHygroGateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gateway of the Webio" + ::= { wtWebGraphThermoHygroNetwork 3 } + +wtWebGraphThermoHygroDnsServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address of the 1st DNS server in ASCII" + ::= { wtWebGraphThermoHygroNetwork 4 } + +wtWebGraphThermoHygroDnsServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address of the 2nd DNS server in ASCII" + ::= { wtWebGraphThermoHygroNetwork 5 } + +wtWebGraphThermoHygroAddConfig OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Additional configuration (1=ON): + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1: DHCP disable + Bit 0: BOOTP disable + " + ::= { wtWebGraphThermoHygroNetwork 6 } + +-- wtWebGraphThermoHygroHTTP Group +-------------------------------- + +wtWebGraphThermoHygroStartup OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded start page: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1: Index.htm + Bit 2: Home.htm + Bit 3: User.htm + Only one page may be selected at a time." + ::= { wtWebGraphThermoHygroHTTP 1 } + +wtWebGraphThermoHygroGetHeaderEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If these bits are set, every answer of a short form GET question will be lead + by the IP-address and name of the device and/or a HTTP header: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-6: unused + Bit 1 : GET HTTP enable + Bit 0 : GET Header enable" + ::= { wtWebGraphThermoHygroHTTP 2 } + +wtWebGraphThermoHygroHttpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Definition of the standard HTML port (Default: 80)." + ::= { wtWebGraphThermoHygroHTTP 3 } + + +-- wtWebGraphThermoHygroMail Group +-------------------------------- + +wtWebGraphThermoHygroMailAdName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Device name for mail administration." + ::= { wtWebGraphThermoHygroMail 1 } + +wtWebGraphThermoHygroMailReply OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reply address for the mail server." + ::= { wtWebGraphThermoHygroMail 2 } + +wtWebGraphThermoHygroMailServer OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the mail server." + ::= { wtWebGraphThermoHygroMail 3 } + +wtWebioAn1MailEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this bit to enable the sending of mails: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Mail enable" + ::= { wtWebGraphThermoHygroMail 4 } + +wtWebGraphThermoHygroMailAuthentication OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Selection of the authentication modi: + The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. + Bit 0 corresponds to the LSB. + OCTET 1: unused + OCTET 2: unused + OCTET 3: unused + OCTET 4: Bit 3-7: unused + Bit 2 : POP3 before SMTP + Bit 1 : ESMTP, authentication + Bit 0 : SMTP, no authentication" + ::= { wtWebGraphThermoHygroMail 5 } + +wtWebGraphThermoHygroMailAuthUser OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name of the user to be authenticated." + ::= { wtWebGraphThermoHygroMail 6 } + +wtWebGraphThermoHygroMailAuthPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Authentication password." + ::= { wtWebGraphThermoHygroMail 7 } + +wtWebGraphThermoHygroMailPop3Server OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or Ip-address of the POP3 Servers." + ::= { wtWebGraphThermoHygroMail 8 } + +-- wtWebGraphThermoHygroSNMP Group +-------------------------------- + +wtWebGraphThermoHygroSnmpCommunityStringRead OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read only" + ::= { wtWebGraphThermoHygroSNMP 1 } + +wtWebGraphThermoHygroSnmpCommunityStringReadWrite OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read / write" + ::= { wtWebGraphThermoHygroSNMP 2 } + +wtWebGraphThermoHygroSystemTrapManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the TCP server which accepts the system trap." + ::= { wtWebGraphThermoHygroSNMP 3 } + +wtWebGraphThermoHygroSystemTrapEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded trigger conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroSNMP 4 } + +wtWebGraphThermoHygroSnmpEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set bit 0 to enable SNMP. + If disabled, the device did not respond to any SNMP requests. + Bit 1 decided wether the community string of read operations + is compared with the system password or not: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : SNMP enable" + ::= { wtWebGraphThermoHygroSNMP 5 } + +wtWebGraphThermoHygroSnmpCommunityStringTrap OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string send within traps." + ::= { wtWebGraphThermoHygroSNMP 6 } + +wtWebGraphThermoHygroSnmpSystemTrapManagerPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Port number of the TCP server which accepts the system trap." + ::= { wtWebGraphThermoHygroSNMP 7 } + +-- wtWebGraphThermoHygroUDP Group +-------------------------------- + +wtWebGraphThermoHygroUdpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Udp port to which the Udp queries ( short form GET requests) can be sent. This + port number must be unique within the device." + ::= { wtWebGraphThermoHygroUDP 1 } + +wtWebGraphThermoHygroUdpEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this bit to enable UDP support: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : UDP enable" + ::= { wtWebGraphThermoHygroUDP 2 } + +-- wtWebGraphThermoHygroSyslog Group +-------------------------------- + +wtWebGraphThermoHygroSyslogServerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the Syslog server, which accepts the Syslog messgaes." + ::= { wtWebGraphThermoHygroSyslog 1 } + +wtWebGraphThermoHygroSyslogServerPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnumber of the Syslog servers, default 514." + ::= { wtWebGraphThermoHygroSyslog 2 } + +wtWebGraphThermoHygroSyslogSystemMessagesEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded trigger conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2: Diag Messages + Bit 3-7: unused" + ::= { wtWebGraphThermoHygroSyslog 3 } + +wtWebGraphThermoHygroSyslogEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set bit 0to enable Syslog: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Syslog enable" + ::= { wtWebGraphThermoHygroSyslog 4 } + +-- wtWebGraphThermoHygroFTP Group +-------------------------------- + +wtWebGraphThermoHygroFTPServerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the FTP server, which accepts the FTP messages." + ::= { wtWebGraphThermoHygroFTP 1 } + +wtWebGraphThermoHygroFTPServerControlPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnumber of the control port of the FTP server, default 21." + ::= { wtWebGraphThermoHygroFTP 2 } + +wtWebGraphThermoHygroFTPUserName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: user name." + ::= { wtWebGraphThermoHygroFTP 3 } + +wtWebGraphThermoHygroFTPPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: user password." + ::= { wtWebGraphThermoHygroFTP 4 } + +wtWebGraphThermoHygroFTPAccount OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: name of account." + ::= { wtWebGraphThermoHygroFTP 5 } + +wtWebGraphThermoHygroFTPOption OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 switches the FTP Server in Passiv-Mode, + the Client controls the data connection on its own: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : PASV enable" + ::= { wtWebGraphThermoHygroFTP 6 } + +wtWebGraphThermoHygroFTPEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set Bit 0 to enable FTP: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : FTP enable" + ::= { wtWebGraphThermoHygroFTP 7 } + +-- wtWebGraphThermoHygroLanguage Group +-------------------------------- + +wtWebGraphThermoHygroLanguageSelect OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sprachauswahl: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 2-7: ungenutzt + Bit 1 : Englisch + Bit 0 : Deutsch" + ::= { wtWebGraphThermoHygroLanguage 1 } + +-- wtWebGraphThermoHygroMQTT Group +-------------------------------- + +wtWebGraphThermoHygroMQTTEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 7 schaltet MQTT frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0-6: ungenutzt + Bit 7 : MQTT enable" + ::= { wtWebGraphThermoHygroMQTT 1 } + +wtWebGraphThermoHygroMQTTBrockerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP-address of the MQTT-Server." + ::= { wtWebGraphThermoHygroMQTT 2 } + +wtWebGraphThermoHygroMQTTUserName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT login user name." + ::= { wtWebGraphThermoHygroMQTT 3 } + +wtWebGraphThermoHygroMQTTPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT login password." + ::= { wtWebGraphThermoHygroMQTT 4 } + +wtWebGraphThermoHygroMQTTLocalPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Local port number." + ::= { wtWebGraphThermoHygroMQTT 5 } + +wtWebGraphThermoHygroMQTTBrokerServerPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Server port number." + ::= { wtWebGraphThermoHygroMQTT 6 } + +wtWebGraphThermoHygroMQTTInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Ping intervall, if no data has to be send: time in seconds." + ::= { wtWebGraphThermoHygroMQTT 7 } + +wtWebGraphThermoHygroMQTTLastWillEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 activate MQTT LastWill message: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : MQTT Last will enable" + ::= { wtWebGraphThermoHygroMQTT 8 } + +wtWebGraphThermoHygroMQTTLastWillTopic OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Last Will Topic." + ::= { wtWebGraphThermoHygroMQTT 9 } + +wtWebGraphThermoHygroMQTTLastWillMsg OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Last Will message." + ::= { wtWebGraphThermoHygroMQTT 10 } + +wtWebGraphThermoHygroMQTTLastWillQoS OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded MQTT Publish QoS: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: QoS 0 + Bit 1: QoS 1 + Bit 2: QoS 2 + Bit 3-7:unused" + ::= { wtWebGraphThermoHygroMQTT 11 } + +wtWebGraphThermoHygroMQTTLastWillRetain OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded MQTT Publish Retain properties: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : retain enable + Bit 1-7 : unused" + ::= { wtWebGraphThermoHygroMQTT 12 } + +wtWebGraphThermoHygroMQTTLastWillConnectEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 activate MQTT LastWill Connect message: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : MQTT Last will connect message enable" + ::= { wtWebGraphThermoHygroMQTT 13 } + +wtWebGraphThermoHygroMQTTLastWillConnectMsg OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Last Will Connect message will be send with the QoS and Retain settings + of the LastWill message." + ::= { wtWebGraphThermoHygroMQTT 14 } + + +-- wtWebGraphThermoHygroREST Group +-------------------------------- + +wtWebGraphThermoHygroRESTEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 activates REST : + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : REST enable" + ::= { wtWebGraphThermoHygroREST 1 } + +wtWebGraphThermoHygroRESTDigestAuthEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 activates Digest-Authentification: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 1-7: unused + Bit 0 : Digest Auth enable" + ::= { wtWebGraphThermoHygroREST 2 } + +-- wtWebGraphThermoHygroDatalogger Group +-------------------------------- + +wtWebGraphThermoHygroLoggerTimebase OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermoHygroDatalogger-1Min(1), + wtWebGraphThermoHygroDatalogger-5Min(2), + wtWebGraphThermoHygroDatalogger-15Min(3), + wtWebGraphThermoHygroDatalogger-60Min(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Time base of the data logger" + ::= { wtWebGraphThermoHygroDatalogger 1 } + +wtWebGraphThermoHygroLoggerSensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded trigger conditions: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroDatalogger 2 } + +-- wtWebGraphThermoHygroRSS Group +-------------------------------- + +wtWebGraphThermoHygroRSSChannelTitle OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 1 } + +wtWebGraphThermoHygroRSSChannelLink OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Link of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 2 } + +wtWebGraphThermoHygroRSSChannelDescription OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Description of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 3 } + +wtWebGraphThermoHygroRSSChannelImage OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Link of a picture, which will be shown at the headline of the output window." + ::= { wtWebGraphThermoHygroRSS 4 } + +wtWebGraphThermoHygroRSSChannelImageTitle OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alias Name of the picture." + ::= { wtWebGraphThermoHygroRSS 5 } + +wtWebGraphThermoHygroRSSChannelImageLink OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Link, which can be selected by clicking on the picture." + ::= { wtWebGraphThermoHygroRSS 6 } + +wtWebGraphThermoHygroRSSChannelItemTitle OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Title of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 7 } + +wtWebGraphThermoHygroRSSChannelItemLink OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Link of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 8 } + +wtWebGraphThermoHygroRSSChannelItemDescription OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text of the RSS Feed." + ::= { wtWebGraphThermoHygroRSS 9 } + +wtWebGraphThermoHygroRSSChannelItemQuantity OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Number of lines." + ::= { wtWebGraphThermoHygroRSS 10 } + +-- wtWebGraphThermoHygroAlarm Group +---------------------------- + +wtWebGraphThermoHygroAlarmCount OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of independent alarms." + ::= { wtWebGraphThermoHygroAlarm 1 } + +-- Alarm Interface Table + +wtWebGraphThermoHygroAlarmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of alarm indices." + ::= { wtWebGraphThermoHygroAlarm 2 } + +wtWebGraphThermoHygroAlarmIfEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroAlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Numbers of the alarms." + INDEX { wtWebGraphThermoHygroAlarmNo } + ::= { wtWebGraphThermoHygroAlarmIfTable 1 } + +WtWebGraphThermoHygroAlarmIfEntry ::= SEQUENCE { + wtWebGraphThermoHygroAlarmNo INTEGER +} + +wtWebGraphThermoHygroAlarmNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Alarm number." + ::= { wtWebGraphThermoHygroAlarmIfEntry 1 } + +-- Alarm Table + +wtWebGraphThermoHygroAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of settings depending on the alarm number." + ::= { wtWebGraphThermoHygroAlarm 3 } + +wtWebGraphThermoHygroAlarmEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroAlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarm parameters of the individual alarms." + INDEX { wtWebGraphThermoHygroAlarmNo } + ::= { wtWebGraphThermoHygroAlarmTable 1 } + +WtWebGraphThermoHygroAlarmEntry ::= SEQUENCE { + wtWebGraphThermoHygroAlarmTrigger OCTET STRING, + wtWebGraphThermoHygroAlarmMin OCTET STRING, + wtWebGraphThermoHygroAlarmMax OCTET STRING, + wtWebGraphThermoHygroAlarmHysteresis OCTET STRING, + wtWebGraphThermoHygroAlarmDelay OCTET STRING, + wtWebGraphThermoHygroAlarmInterval OCTET STRING, + wtWebGraphThermoHygroAlarmEnable OCTET STRING, + wtWebGraphThermoHygroAlarmEMailAddr OCTET STRING, + wtWebGraphThermoHygroAlarmMailSubject OCTET STRING, + wtWebGraphThermoHygroAlarmMailText OCTET STRING, + wtWebGraphThermoHygroAlarmManagerIP OCTET STRING, + wtWebGraphThermoHygroAlarmTrapText OCTET STRING, + wtWebGraphThermoHygroAlarmMailOptions OCTET STRING, + wtWebGraphThermoHygroAlarmTcpIpAddr OCTET STRING, + wtWebGraphThermoHygroAlarmTcpPort INTEGER, + wtWebGraphThermoHygroAlarmTcpText OCTET STRING, + wtWebGraphThermoHygroAlarmClearMailSubject OCTET STRING, + wtWebGraphThermoHygroAlarmClearMailText OCTET STRING, + wtWebGraphThermoHygroAlarmClearTrapText OCTET STRING, + wtWebGraphThermoHygroAlarmClearTcpText OCTET STRING, + wtWebGraphThermoHygroAlarmDeltaTemp OCTET STRING, + wtWebGraphThermoHygroAlarmRHMin OCTET STRING, + wtWebGraphThermoHygroAlarmRHMax OCTET STRING, + wtWebGraphThermoHygroAlarmRHHysteresis OCTET STRING, + wtWebGraphThermoHygroAlarmAHMin OCTET STRING, + wtWebGraphThermoHygroAlarmAHMax OCTET STRING, + wtWebGraphThermoHygroAlarmSyslogIpAddr OCTET STRING, + wtWebGraphThermoHygroAlarmSyslogPort INTEGER, + wtWebGraphThermoHygroAlarmSyslogText OCTET STRING, + wtWebGraphThermoHygroAlarmSyslogClearText OCTET STRING, + wtWebGraphThermoHygroAlarmFtpDataPort OCTET STRING, + wtWebGraphThermoHygroAlarmFtpFileName OCTET STRING, + wtWebGraphThermoHygroAlarmFtpText OCTET STRING, + wtWebGraphThermoHygroAlarmFtpClearText OCTET STRING, + wtWebGraphThermoHygroAlarmFtpOption OCTET STRING, + wtWebGraphThermoHygroAlarmTimerCron OCTET STRING, + wtWebGraphThermoHygroAlarmName OCTET STRING, + wtWebGraphThermoHygroAlarmActive OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqAuthEnable OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqAuthUser OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqAuthPassword OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqSetUrl OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqClearUrl OCTET STRING, + wtWebGraphThermoHygroAlarmHttpReqServerPort INTEGER, + wtWebGraphThermoHygroAlarmMqttTopicPath OCTET STRING, + wtWebGraphThermoHygroAlarmMqttTopicSetTopic OCTET STRING, + wtWebGraphThermoHygroAlarmMqttTopicClear OCTET STRING, + wtWebGraphThermoHygroAlarmSensorLostSelection OCTET STRING, + wtWebGraphThermoHygroAlarmLimitWindow OCTET STRING, + wtWebGraphThermoHygroAlarmSnmpManagerPort INTEGER, + wtWebGraphThermoHygroAlarmMqttQoS OCTET STRING, + wtWebGraphThermoHygroAlarmMqttRetain OCTET STRING +} + +wtWebGraphThermoHygroAlarmTrigger OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded trigger conditions: + Octet 1: unused + Octet 2: unused + Octet 3: + Bit 0: Timer + Bit 1: ColdStart + Bit 2: WarmStart + + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroAlarmEntry 1 } + +wtWebGraphThermoHygroAlarmMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum temperature in degrees with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 2 } + +wtWebGraphThermoHygroAlarmMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum temperature in degrees with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 3 } + +wtWebGraphThermoHygroAlarmHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) + , in degrees with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 4 } + +wtWebGraphThermoHygroAlarmDelay OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alarm will be delayed by setting this time while stable alarm + condition occur (time in minutes)." + ::= { wtWebGraphThermoHygroAlarmEntry 5 } + + +wtWebGraphThermoHygroAlarmInterval OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Send interval for alarm messages." + ::= { wtWebGraphThermoHygroAlarmEntry 6 } + +wtWebGraphThermoHygroAlarmEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded alarm enable: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: Mail Enable + Bit 1: SNMP Trap enable + Bit 2: TCP Client enable" + ::= { wtWebGraphThermoHygroAlarmEntry 7 } + +wtWebGraphThermoHygroAlarmEMailAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "E-Mail address for sending the alarm mail to." + ::= { wtWebGraphThermoHygroAlarmEntry 8 } + +wtWebGraphThermoHygroAlarmMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subject line for alarm mail." + ::= { wtWebGraphThermoHygroAlarmEntry 9 } + +wtWebGraphThermoHygroAlarmMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alarm mail text: provides the current temperature; n = 1..8. + provides the current time." + ::= { wtWebGraphThermoHygroAlarmEntry 10 } + +wtWebGraphThermoHygroAlarmManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the SNMP Manager which accepts the trap." + ::= { wtWebGraphThermoHygroAlarmEntry 11 } + +wtWebGraphThermoHygroAlarmTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This text is sent in the trap body." + ::= { wtWebGraphThermoHygroAlarmEntry 12 } + +wtWebGraphThermoHygroAlarmMailOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded options: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : Attach Thermo.csv Enable + Bit 1 : CSV-Data_since_last_report + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroAlarmEntry 13 } + +wtWebGraphThermoHygroAlarmTcpIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name or IP address of the TCP server which accepts the trap." + ::= { wtWebGraphThermoHygroAlarmEntry 14 } + +wtWebGraphThermoHygroAlarmTcpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Port number of the TCP server which accepts the trap." + ::= { wtWebGraphThermoHygroAlarmEntry 15 } + +wtWebGraphThermoHygroAlarmTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This text is sent in the TCP trap body." + ::= { wtWebGraphThermoHygroAlarmEntry 16 } + +wtWebGraphThermoHygroAlarmClearMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subject line for alarm clear mail." + ::= { wtWebGraphThermoHygroAlarmEntry 17 } + +wtWebGraphThermoHygroAlarmClearMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alarm clear mail text: provides the current temperature; n = 1..8. + provides the current time." + ::= { wtWebGraphThermoHygroAlarmEntry 18 } + +wtWebGraphThermoHygroAlarmClearTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This text is sent in the trap body." + ::= { wtWebGraphThermoHygroAlarmEntry 19 } + +wtWebGraphThermoHygroAlarmClearTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This text is sent in the TCP trap body." + ::= { wtWebGraphThermoHygroAlarmEntry 20 } + +wtWebGraphThermoHygroAlarmDeltaTemp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum rate of change degrees/min with maximum 2 decimal places. + Compared with the average of a period of 5 minutes." + ::= { wtWebGraphThermoHygroAlarmEntry 21 } + +wtWebGraphThermoHygroAlarmRHMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum rel. Humidity in percent with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 22 } + +wtWebGraphThermoHygroAlarmRHMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum rel.Humidity in percent with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 23 } + +wtWebGraphThermoHygroAlarmRHHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hysterese rel. Humidity in percent with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 24 } + +wtWebGraphThermoHygroAlarmAHMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 25 } + +wtWebGraphThermoHygroAlarmAHMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroAlarmEntry 26 } + +wtWebGraphThermoHygroAlarmSyslogIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP address of the syslog server to which the Webio device should send syslog messages." + ::= { wtWebGraphThermoHygroAlarmEntry 27 } + +wtWebGraphThermoHygroAlarmSyslogPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Port number of the syslog server to which the Webio device should send syslog messages." + ::= { wtWebGraphThermoHygroAlarmEntry 28 } + +wtWebGraphThermoHygroAlarmSyslogText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. + This text appears in the following syslog message body." + ::= { wtWebGraphThermoHygroAlarmEntry 29 } + +wtWebGraphThermoHygroAlarmSyslogClearText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. + This text appears in the following syslog message body." + ::= { wtWebGraphThermoHygroAlarmEntry 30 } + +wtWebGraphThermoHygroAlarmFtpDataPort OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Local data port: 1..65535 or AUTO: the next free port will be assigned." + ::= { wtWebGraphThermoHygroAlarmEntry 31 } + +wtWebGraphThermoHygroAlarmFtpFileName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name of the file including path informations." + ::= { wtWebGraphThermoHygroAlarmEntry 32 } + +wtWebGraphThermoHygroAlarmFtpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Message text to store on the FTP server." + ::= { wtWebGraphThermoHygroAlarmEntry 33 } + +wtWebGraphThermoHygroAlarmFtpClearText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alarm clear message to store on the FTP server." + ::= { wtWebGraphThermoHygroAlarmEntry 34 } + +wtWebGraphThermoHygroAlarmFtpOption OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded options, select only one option at the same time: + STORE = replace file + APPEND = append message at the end of the file + + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : STORE + Bit 1 : APPEND + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroAlarmEntry 35 } + +wtWebGraphThermoHygroAlarmTimerCron OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This entry contains 5 space or tab seperated text fields for time trigger definition. + Each field must match with the actual time to trigger a message, weekday and day of month + are interpreted separatley. + 1: Minutes Range 0-59 + 2. Hours Range 0-23, 0 is midnight + 3: Day of month Range 1-31 + 4: Month Range 1-12 + 5: Weekday Range 0-6, 0 is sunday + + Syntax for every field: + - an asterix (*) enables every possible setting of a field + - single numbers seperated by commas + - a partition within the allowed range (1-5) + - step size within an partition of the allowed range (0-59/2: every second minute)." + ::= { wtWebGraphThermoHygroAlarmEntry 36 } + +-- __JB__ +wtWebGraphThermoHygroAlarmName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alert name" + ::= { wtWebGraphThermoHygroAlarmEntry 39 } + +-- __JB__ +wtWebGraphThermoHygroAlarmActive OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Alert active + 1 = ON + 0 = OFF" + ::= { wtWebGraphThermoHygroAlarmEntry 40 } + +wtWebGraphThermoHygroAlarmHttpReqAuthEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded options, select only one option at the same time: + OCTET 1: unused + OCTET 2: unused + OCTET 3: unused + OCTET 4, Bit 1-7: unused + Bit 0 : HHTP Request Authentication enable" + ::= { wtWebGraphThermoHygroAlarmEntry 61 } + +wtWebGraphThermoHygroAlarmHttpReqAuthUser OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Request: User" + ::= { wtWebGraphThermoHygroAlarmEntry 62 } + +wtWebGraphThermoHygroAlarmHttpReqAuthPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Request: Password" + ::= { wtWebGraphThermoHygroAlarmEntry 63 } + +wtWebGraphThermoHygroAlarmHttpReqSetUrl OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Request: Set URL" + ::= { wtWebGraphThermoHygroAlarmEntry 64 } + +wtWebGraphThermoHygroAlarmHttpReqClearUrl OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Request: Clear URL" + ::= { wtWebGraphThermoHygroAlarmEntry 65 } + +wtWebGraphThermoHygroAlarmHttpReqServerPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Request: Server Port" + ::= { wtWebGraphThermoHygroAlarmEntry 66 } + +wtWebGraphThermoHygroAlarmMqttTopicPath OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Publish: Topic path" + ::= { wtWebGraphThermoHygroAlarmEntry 67 } + +wtWebGraphThermoHygroAlarmMqttTopicSetTopic OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Publish: Topic SET message" + ::= { wtWebGraphThermoHygroAlarmEntry 68 } + +wtWebGraphThermoHygroAlarmMqttTopicClear OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "MQTT Publish: Topic CLEAR message" + ::= { wtWebGraphThermoHygroAlarmEntry 69 } + +wtWebGraphThermoHygroAlarmSensorLostSelection OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded options: + OCTET 1: unused + OCTET 2: unused + OCTET 3: unused + OCTET 4, Bit 2-7: unused + Bit 1 : Sensor 1 + Bit 0 : Sensor 0" + ::= { wtWebGraphThermoHygroAlarmEntry 70 } + +wtWebGraphThermoHygroAlarmLimitWindow OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If window type is INSIDE the alarm is genereted when the temperature + is greater minumum value and lower than maximum value. If window type is OUTSIDE + the alarm is generated when the measured value is lower than the minimum value + or greater than the maximum value. + Binary coded options, select only one option at the same time: + OCTET 1: unused + OCTET 2: unused + OCTET 3: unused + OCTET 4, Bit 2-7: unused + Bit 1 : inside window + Bit 0 : outside window" + ::= { wtWebGraphThermoHygroAlarmEntry 71 } + +wtWebGraphThermoHygroAlarmSnmpManagerPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Port number of the SNMP Manager to which the Webio device should send SNMP traps." + ::= { wtWebGraphThermoHygroAlarmEntry 76 } + +wtWebGraphThermoHygroAlarmMqttQoS OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded value: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: QoS 0 + Bit 1: QoS 1 + Bit 2: QoS 2 + Bit 3-7:unused" + ::= { wtWebGraphThermoHygroAlarmEntry 77 } + +wtWebGraphThermoHygroAlarmMqttRetain OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded value: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : retain enable + Bit 1-7 : unused" + ::= { wtWebGraphThermoHygroAlarmEntry 78 } + +-- wtWebGraphThermoHygroGraphicsBase Group +---------------------------- + +wtWebGraphThermoHygroGraphicsBaseEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the viewing options of the graphic: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : Auto scroll enable + Bit 1 : Show table + Bit 2 : Show graph + Bit 3 : Show control buttons + Bit 4 : Show config menu + Bit 5-7: unused" + ::= { wtWebGraphThermoHygroGraphicsBase 1 } + +wtWebGraphThermoHygroGraphicsBaseWidth OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the width of the graphic in pixels." + ::= { wtWebGraphThermoHygroGraphicsBase 2 } + +wtWebGraphThermoHygroGraphicsBaseHeight OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the height of the graphic in pixels." + ::= { wtWebGraphThermoHygroGraphicsBase 3 } + +wtWebGraphThermoHygroGraphicsBaseFrameColor OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(3)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Frame color definition in RGB." + ::= { wtWebGraphThermoHygroGraphicsBase 4 } + +wtWebGraphThermoHygroGraphicsBaseBackgroundColor OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(3)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Background color definition in RGB." + ::= { wtWebGraphThermoHygroGraphicsBase 5 } + +wtWebGraphThermoHygroGraphicsBasePollingrate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Defines the pollingrate in seconds, + which defines the refreshing intervall of the graphic." + ::= { wtWebGraphThermoHygroGraphicsBase 6 } + +-- wtWebGraphThermoHygroGraphicsSelect Group +---------------------------- + +wtWebGraphThermoHygroGraphicsSelectDisplaySensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded sensor selection: + only selected sensors will be shown in the graphical presentation: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroGraphicsSelect 1 } + +wtWebGraphThermoHygroGraphicsSelectDisplayShowExtrem OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binary coded sensor selection: + only selected sensors will be shown with minima and maxima: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroGraphicsSelect 2 } + +-- Graph Sensor Color Table + +wtWebGraphThermoHygroSensorColorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorColorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of sensor colors for the praphical presentation." + ::= { wtWebGraphThermoHygroGraphicsSelect 3 } + +wtWebGraphThermoHygroSensorColorEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroSensorColorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Numbers of the sensors." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroSensorColorTable 1 } + +WtWebGraphThermoHygroSensorColorEntry ::= SEQUENCE { + wtWebGraphThermoHygroGraphicsSensorColor OCTET STRING, + wtWebGraphThermoHygroGraphicsSelectScale OCTET STRING +} + +wtWebGraphThermoHygroGraphicsSensorColor OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(3)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Color of the sensors at the praphical presention." + ::= { wtWebGraphThermoHygroSensorColorEntry 1 } + +wtWebGraphThermoHygroGraphicsSelectScale OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Assignes one of 4 scales to a sensor: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : Use Scale 1 + Bit 1 : Use Scale 2 + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroSensorColorEntry 2 } + +-- wtWebGraphThermoHygroGraphicsScale Group +---------------------------- + +wtWebGraphThermoHygroGraphicsScaleAutoScaleEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Select the Auto Scale Mode: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : Scale 1 Auto scale enable + Bit 1 : Scale 2 Auto scale enable + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroGraphicsScale 1 } + + +wtWebGraphThermoHygroGraphicsScaleAutoFitEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Select the Auto Fit Mode:: + Octet 1: unused + Octet 2: unused + Octet 3: unused + Octet 4: + Bit 0 : Scale 1 Auto fit enable + Bit 1 : Scale 2 Auto fit enable + Bit 2-7: unused" + ::= { wtWebGraphThermoHygroGraphicsScale 2 } + +wtWebGraphThermoHygroGraphicsScale1Min OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 1: Minimum." + ::= { wtWebGraphThermoHygroGraphicsScale 3 } + +wtWebGraphThermoHygroGraphicsScale2Min OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 2: Minimum." + ::= { wtWebGraphThermoHygroGraphicsScale 4 } + +wtWebGraphThermoHygroGraphicsScale3Min OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 3: Minimum." + ::= { wtWebGraphThermoHygroGraphicsScale 5 } + +wtWebGraphThermoHygroGraphicsScale4Min OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 4: Minimum." + ::= { wtWebGraphThermoHygroGraphicsScale 6 } + +wtWebGraphThermoHygroGraphicsScale1Max OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 1: Maximum." + ::= { wtWebGraphThermoHygroGraphicsScale 7 } + +wtWebGraphThermoHygroGraphicsScale2Max OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 2: Maximum." + ::= { wtWebGraphThermoHygroGraphicsScale 8 } + +wtWebGraphThermoHygroGraphicsScale3Max OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 3: Maximum." + ::= { wtWebGraphThermoHygroGraphicsScale 9 } + +wtWebGraphThermoHygroGraphicsScale4Max OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 4: Maximum." + ::= { wtWebGraphThermoHygroGraphicsScale 10 } + +wtWebGraphThermoHygroGraphicsScale1Unit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 1: Unit." + ::= { wtWebGraphThermoHygroGraphicsScale 11 } + +wtWebGraphThermoHygroGraphicsScale2Unit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 2: Unit." + ::= { wtWebGraphThermoHygroGraphicsScale 12 } + +wtWebGraphThermoHygroGraphicsScale3Unit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 3: Unit." + ::= { wtWebGraphThermoHygroGraphicsScale 13 } + +wtWebGraphThermoHygroGraphicsScale4Unit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Scale 4: Unit." + ::= { wtWebGraphThermoHygroGraphicsScale 14 } + + +-- wtWebGraphThermoHygroPorts Group +---------------------------- + +-- Table + +wtWebGraphThermoHygroPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermoHygroPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "List of settings depending on the sensor number." + ::= { wtWebGraphThermoHygroPorts 1 } + +wtWebGraphThermoHygroPortEntry OBJECT-TYPE + SYNTAX WtWebGraphThermoHygroPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sensor parameters for the individual sensors." + INDEX { wtWebGraphThermoHygroSensorNo } + ::= { wtWebGraphThermoHygroPortTable 1 } + +WtWebGraphThermoHygroPortEntry ::= SEQUENCE { + wtWebGraphThermoHygroPortName OCTET STRING, + wtWebGraphThermoHygroPortText OCTET STRING, + wtWebGraphThermoHygroPortOffset1 OCTET STRING, + wtWebGraphThermoHygroPortTemperature1 OCTET STRING, + wtWebGraphThermoHygroPortOffset2 OCTET STRING, + wtWebGraphThermoHygroPortTemperature2 OCTET STRING, + wtWebGraphThermoHygroPortComment OCTET STRING +} + +wtWebGraphThermoHygroPortName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name of the sensor." + ::= { wtWebGraphThermoHygroPortEntry 1 } + +wtWebGraphThermoHygroPortText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Description of the sensor." + ::= { wtWebGraphThermoHygroPortEntry 2 } + +wtWebGraphThermoHygroPortOffset1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1." + ::= { wtWebGraphThermoHygroPortEntry 3 } + +wtWebGraphThermoHygroPortTemperature1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroPortEntry 4 } + +wtWebGraphThermoHygroPortOffset2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2." + ::= { wtWebGraphThermoHygroPortEntry 5 } + +wtWebGraphThermoHygroPortTemperature2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." + ::= { wtWebGraphThermoHygroPortEntry 6 } + +wtWebGraphThermoHygroPortComment OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset calibration: informations of date, name of operator, reference devices." + ::= { wtWebGraphThermoHygroPortEntry 7 } + +wtWebGraphThermoHygroPortAltidude OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Altidude oh the Sensor over mean sea level (MSL)." + ::= { wtWebGraphThermoHygroPorts 2 } + +-- wtWebGraphThermoHygroManufact Group +---------------------------- + +wtWebGraphThermoHygroMfName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer company name" + ::= { wtWebGraphThermoHygroManufact 1 } + +wtWebGraphThermoHygroMfAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer address." + ::= { wtWebGraphThermoHygroManufact 2 } + +wtWebGraphThermoHygroMfHotline OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer hotline." + ::= { wtWebGraphThermoHygroManufact 3 } + +wtWebGraphThermoHygroMfInternet OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer Internet address." + ::= { wtWebGraphThermoHygroManufact 4 } + +wtWebGraphThermoHygroMfDeviceTyp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer device name (model number)." + ::= { wtWebGraphThermoHygroManufact 5 } + +wtWebGraphThermoHygroMfOrderNo OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Manufacturer part number." + ::= { wtWebGraphThermoHygroManufact 6 } + +-- wtWebGraphThermoHygroDiag Group +---------------------------- + +wtWebGraphThermoHygroDiagErrorCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of entries in the error memory." + ::= { wtWebGraphThermoHygroDiag 1 } + +wtWebGraphThermoHygroDiagBinaryError OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Error causes coded bit-by-bit." + ::= { wtWebGraphThermoHygroDiag 2 } + +wtWebGraphThermoHygroDiagErrorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of this variable is used as an index to read + an error massege from wtWebGraphThermoHygroDiagErrorMessage. + Errors are numbered from 1 to wtWebGraphThermoHygroDiagErrorCount. + Writing a valid value into this variable, making the appropriate + message readable from wtWebGraphThermoHygroDiagErrorMessage." + ::= { wtWebGraphThermoHygroDiag 3 } + +wtWebGraphThermoHygroDiagErrorMessage OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Using wtWebGraphThermoHygroDiagErrorIndex as an index, the appropriate message is available." + ::= { wtWebGraphThermoHygroDiag 4 } + +wtWebGraphThermoHygroDiagErrorClear OBJECT-TYPE + SYNTAX INTEGER + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Writing 1 into this variable clears all diagnosis messages." + ::= { wtWebGraphThermoHygroDiag 5 } + +-- TRAP DEFINITIONS + +-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen + +wtWebGraphThermoHygroAlert1 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 1 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 31 + +wtWebGraphThermoHygroAlert2 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 2 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 32 + +wtWebGraphThermoHygroAlert3 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 3 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 33 + +wtWebGraphThermoHygroAlert4 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 4 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 34 + +wtWebGraphThermoHygroAlert5 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 5 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 35 + +wtWebGraphThermoHygroAlert6 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 6 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 36 + +wtWebGraphThermoHygroAlert7 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 7 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 37 + +wtWebGraphThermoHygroAlert8 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 8 was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 38 + + +wtWebGraphThermoHygroAlert9 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 1 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 1" + --#SUMMARY "Release Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 91 + +wtWebGraphThermoHygroAlert10 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 2 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 2" + --#SUMMARY "Release Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 92 + +wtWebGraphThermoHygroAlert11 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 3 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 3" + --#SUMMARY "Release Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 93 + +wtWebGraphThermoHygroAlert12 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 4 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 4" + --#SUMMARY "Release Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 94 + +wtWebGraphThermoHygroAlert13 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 5 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 5" + --#SUMMARY "Release Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 95 + +wtWebGraphThermoHygroAlert14 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 6 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 6" + --#SUMMARY "Release Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 96 + +wtWebGraphThermoHygroAlert15 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 7 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 7" + --#SUMMARY "Release Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 97 + +wtWebGraphThermoHygroAlert16 TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText } + DESCRIPTION + "This SNMP trap is generated when Alarm 8 was cleared, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 8" + --#SUMMARY "Release Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 98 + +wtWebGraphThermoHygroAlertDiag TRAP-TYPE + ENTERPRISE wtWebGraphThermoHygro + VARIABLES { + wtWebGraphThermoHygroDiagErrorIndex, + wtWebGraphThermoHygroDiagErrorMessage + } + DESCRIPTION + "This SNMP trap is generated when a diagnosis/error message was triggered, + SNMP trap enable is set and + SNMP is enabled." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Diagnose Error" + --#SUMMARY "Diagnose error index: %d, Message: %s." + --#ARGUMENTS {0,1} + --#SEVERITY MAJOR + --#TIMEINDEX 99 + --#STATE DEGRADED + ::= 110 + +END -- cgit v1.2.3