From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/telco-systems/binox/PRVT-LMM-MIB | 426 ++++++++++++++++++++++++++++++++++ 1 file changed, 426 insertions(+) create mode 100644 MIBS/telco-systems/binox/PRVT-LMM-MIB (limited to 'MIBS/telco-systems/binox/PRVT-LMM-MIB') diff --git a/MIBS/telco-systems/binox/PRVT-LMM-MIB b/MIBS/telco-systems/binox/PRVT-LMM-MIB new file mode 100644 index 0000000..dfabf0d --- /dev/null +++ b/MIBS/telco-systems/binox/PRVT-LMM-MIB @@ -0,0 +1,426 @@ +-- ********************************************************************* +-- ** +-- ** BATM Advanced Communications. +-- ** +-- ********************************************************************* +-- ** Filename: PRVT-LMM-MIB.mib +-- ** Project: T-Metro Switches. +-- ** Purpose: Private MIB +-- ********************************************************************* +-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved. +-- WARNING: +-- +-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: +-- +-- This file is the property of BATM Advanced Communications and contains +-- proprietary and confidential information. This file is made +-- available to authorized BATM customers on the express +-- condition that neither it, nor any of the information contained +-- therein, shall be disclosed to third parties or be used for any +-- purpose other than to replace, modify or upgrade firmware and/or +-- software components of BATM manufactured equipment within the +-- authorized customer's network, and that such transfer be +-- completed in accordance with the instructions provided by +-- BATM. Any other use is strictly prohibited. +-- +-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED +-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE +-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED +-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES +-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. +-- +-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER +-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS +-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR +-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY +-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. +-- +-- ---------------------------------------------------------------------------- + +PRVT-LMM-MIB DEFINITIONS ::= BEGIN + +IMPORTS + ifIndex + FROM IF-MIB + switch + FROM PRVT-SWITCH-MIB + Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE + FROM SNMPv2-SMI + TruthValue + FROM SNMPv2-TC; + +prvtLmmMIB MODULE-IDENTITY + LAST-UPDATED "201110110000Z" + ORGANIZATION + "BATM Advanced Communication" + CONTACT-INFO + "BATM/Telco Systems Support team + Email: + For North America: techsupport@telco.com + For North Europe: support@batm.de, info@batm.de + For the rest of the world: techsupport@telco.com" + DESCRIPTION + "Initial version. This MIB will configure laser monitoring" + REVISION "201110110000Z" + DESCRIPTION + "Initial release" + ::= { switch 172 } + + +prvtLmmNotifications OBJECT IDENTIFIER + ::= { prvtLmmMIB 0 } + +prvtLmmObjects OBJECT IDENTIFIER + ::= { prvtLmmMIB 1 } + +prvtLmmShutdown OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable laser monitoring" + ::= { prvtLmmObjects 1 } + +prvtLmmDebug OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable laser monitoring" + ::= { prvtLmmObjects 2 } + +prvtLmmPeriod OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the monitoring interval (sec)." + ::= { prvtLmmObjects 3 } + +prvtLmmTrap OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable sending SNMP traps when thresholds are crossed" + ::= { prvtLmmObjects 4 } + +prvtLmmLog OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable alert notification logging when thresholds are crossed" + ::= { prvtLmmObjects 5 } + +prvtLmmLed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable LED-alert notifications when thresholds are crossed" + ::= { prvtLmmObjects 6 } + +prvtLmmTemperatureHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-128..128) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for global temperature (-128 up to 128). + prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold" + ::= { prvtLmmObjects 7 } + +prvtLmmTemperatureLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-128..128) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for global temperature (-128 up to 128). + prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold" + ::= { prvtLmmObjects 8 } + +prvtLmmRxPowerLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for global RX-power (-40 up to 8) + prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold" + ::= { prvtLmmObjects 9 } + +prvtLmmRxPowerHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the high threshold value for global RX-power (-40 up to 8) + prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold" + ::= { prvtLmmObjects 10 } + +prvtLmmTxPowerLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for global RX-power (-40 up to 8) + prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold" + ::= { prvtLmmObjects 11 } + +prvtLmmTxPowerHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the high threshold value for global RX-power (-40 up to 8) + prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold" + ::= { prvtLmmObjects 12 } + +prvtLmmInterfaceTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLmmInterfaceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Lmm configuration per ethernet port" + ::= { prvtLmmObjects 13 } + +prvtLmmInterfaceEntry OBJECT-TYPE + SYNTAX PrvtLmmInterfaceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The Stack table entry" + INDEX { ifIndex } + ::= { prvtLmmInterfaceTable 1 } + +PrvtLmmInterfaceEntry ::= SEQUENCE { + prvtLmmInterfaceShutdown TruthValue, + prvtLmmInterfaceTempLowThreshold Integer32, + prvtLmmInterfaceTempHighThreshold Integer32, + prvtLmmInterfaceTempValue Integer32, + prvtLmmInterfaceTempThresholdLo Integer32, + prvtLmmInterfaceTempThresholdHi Integer32, + prvtLmmInterfaceTempTestState TruthValue, + prvtLmmInterfaceRxPowerLowThreshold Integer32, + prvtLmmInterfaceRxPowerHighThreshold Integer32, + prvtLmmInterfaceRxPowerValue Integer32, + prvtLmmInterfaceRxPowerThresholdRxLo Integer32, + prvtLmmInterfaceRxPowerThresholdRxHi Integer32, + prvtLmmInterfaceRxPowerTestState TruthValue, + prvtLmmInterfaceTxPowerLowThreshold Integer32, + prvtLmmInterfaceTxPowerHighThreshold Integer32, + prvtLmmInterfaceTxPowerValue Integer32, + prvtLmmInterfaceTxPowerThresholdTxLo Integer32, + prvtLmmInterfaceTxPowerThresholdTxHi Integer32, + prvtLmmInterfaceTxPowerTestState TruthValue, + prvtLmmInterfaceOperStatus TruthValue +} + +prvtLmmInterfaceShutdown OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable laser monitoring on port" + ::= { prvtLmmInterfaceEntry 1 } + +prvtLmmInterfaceTempLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-128..128) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for port temperature" + ::= { prvtLmmInterfaceEntry 2 } + +prvtLmmInterfaceTempHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-128..128) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the high threshold value for port temperature. + Value of prvtLmmInterfaceTempHighThreshold must be greater than + prvtLmmInterfaceTempLowThreshold" + ::= { prvtLmmInterfaceEntry 3 } + +prvtLmmInterfaceTempValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display laser Temperature current value" + ::= { prvtLmmInterfaceEntry 4 } + +prvtLmmInterfaceTempThresholdLo OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 5 } + +prvtLmmInterfaceTempThresholdHi OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 6 } + +prvtLmmInterfaceTempTestState OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state test" + ::= { prvtLmmInterfaceEntry 7 } + +prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for port RX-power." + ::= { prvtLmmInterfaceEntry 8 } + +prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the high threshold value for port RX-power. + Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than + prvtLmmInterfaceRxPowerLowThreshold" + ::= { prvtLmmInterfaceEntry 9 } + +prvtLmmInterfaceRxPowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display laser Rx Power current value" + ::= { prvtLmmInterfaceEntry 10 } + +prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 11 } + +prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 12 } + +prvtLmmInterfaceRxPowerTestState OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state test" + ::= { prvtLmmInterfaceEntry 13 } + +prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the low threshold value for port TX-power" + ::= { prvtLmmInterfaceEntry 14 } + +prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-40..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the high threshold value for port TX-power + Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than + prvtLmmInterfaceTxPowerLowThreshold" + ::= { prvtLmmInterfaceEntry 15 } + +prvtLmmInterfaceTxPowerValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Display laser Tx Power current value" + ::= { prvtLmmInterfaceEntry 16 } + +prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 17 } + +prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The thresholds read from hardware or set by user" + ::= { prvtLmmInterfaceEntry 18 } + +prvtLmmInterfaceTxPowerTestState OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state test" + ::= { prvtLmmInterfaceEntry 19 } + +prvtLmmInterfaceOperStatus OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational status" + ::= { prvtLmmInterfaceEntry 20 } + +prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE + OBJECTS { prvtLmmInterfaceTempValue, + prvtLmmInterfaceTempThresholdHi, + prvtLmmInterfaceTempThresholdLo } + STATUS current + DESCRIPTION + "The prvtLmmTemperatureThresholdCrossed shall be generated + when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi + or falls below prvtLmmInterfaceTempThresholdLo. Also the + notification shall be generated when prvtLmmInterfaceTempValue + returns to the normal range between prvtLmmInterfaceTempThresholdHi + and prvtLmmInterfaceTempThresholdLo." + ::= { prvtLmmNotifications 1 } + +prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE + OBJECTS { prvtLmmInterfaceTxPowerValue, + prvtLmmInterfaceTxPowerThresholdTxHi, + prvtLmmInterfaceTxPowerThresholdTxLo } + STATUS current + DESCRIPTION + "The prvtLmmTxPowerThresholdCrossed shall be generated + when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi + or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the + notification shall be generated when prvtLmmInterfaceTxPowerValue + returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi + and prvtLmmInterfaceTxPowerThresholdTxLo." + ::= { prvtLmmNotifications 2 } + +prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE + OBJECTS { prvtLmmInterfaceRxPowerValue, + prvtLmmInterfaceRxPowerThresholdRxHi, + prvtLmmInterfaceRxPowerThresholdRxLo } + STATUS current + DESCRIPTION + "The prvtLmmRxPowerThresholdCrossed shall be generated + when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi + or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the + notification shall be generated when prvtLmmInterfaceRxPowerValue + returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi + and prvtLmmInterfaceRxPowerThresholdRxLo." + ::= { prvtLmmNotifications 3 } + +END -- end of module PRVT-LMM-MIB. -- cgit v1.2.3