From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/telco-systems/binox/PRVT-LLDP-MIB | 763 +++++++++++++++++++++++++++++++++ 1 file changed, 763 insertions(+) create mode 100644 MIBS/telco-systems/binox/PRVT-LLDP-MIB (limited to 'MIBS/telco-systems/binox/PRVT-LLDP-MIB') diff --git a/MIBS/telco-systems/binox/PRVT-LLDP-MIB b/MIBS/telco-systems/binox/PRVT-LLDP-MIB new file mode 100644 index 0000000..320c762 --- /dev/null +++ b/MIBS/telco-systems/binox/PRVT-LLDP-MIB @@ -0,0 +1,763 @@ +-- ********************************************************************* +-- ** +-- ** BATM Advanced Communications. +-- ** +-- ********************************************************************* +-- ** Filename: PRVT-LLDP-MIB.mib +-- ** Project: T-Metro Switches. +-- ** Purpose: Private MIB +-- ********************************************************************* +-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved. +-- WARNING: +-- +-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: +-- +-- This file is the property of BATM Advanced Communications and contains +-- proprietary and confidential information. This file is made +-- available to authorized BATM customers on the express +-- condition that neither it, nor any of the information contained +-- therein, shall be disclosed to third parties or be used for any +-- purpose other than to replace, modify or upgrade firmware and/or +-- software components of BATM manufactured equipment within the +-- authorized customer's network, and that such transfer be +-- completed in accordance with the instructions provided by +-- BATM. Any other use is strictly prohibited. +-- +-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED +-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE +-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED +-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES +-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. +-- +-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER +-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS +-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR +-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY +-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. +-- +-- ---------------------------------------------------------------------------- + +PRVT-LLDP-MIB DEFINITIONS ::= BEGIN + +IMPORTS + switch + FROM PRVT-SWITCH-MIB + Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, + Unsigned32 + FROM SNMPv2-SMI + PhysAddress, RowStatus, TruthValue + FROM SNMPv2-TC; + +prvtLldpMIB MODULE-IDENTITY + LAST-UPDATED "200907280000Z" + ORGANIZATION + "BATM Advanced Communication" + CONTACT-INFO + "BATM/Telco Systems Support team + Email: + For North America: techsupport@telco.com + For North Europe: support@batm.de, info@batm.de + For the rest of the world: techsupport@telco.com" + DESCRIPTION + "Management Information Base module for LLDP configuration" + REVISION "200907280000Z" + DESCRIPTION + "Initial revision." + ::= { switch 145 } + + +prvtlldpNotifications OBJECT IDENTIFIER + ::= { prvtLldpMIB 0 } + +prvtLldpObjects OBJECT IDENTIFIER + ::= { prvtLldpMIB 1 } + +prvtLldpEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable the LLDP on the device" + ::= { prvtLldpObjects 1 } + +prvtLldpReinitDelay OBJECT-TYPE + SYNTAX Unsigned32 (1..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the time interval (in [s]) at + which the interface is checked if is enabled + again so that the port can be reinitialized" + ::= { prvtLldpObjects 2 } + +prvtLldpSnmpNotifyInterval OBJECT-TYPE + SYNTAX Unsigned32 (5..3600) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the SNMP notification interval (in [s])" + ::= { prvtLldpObjects 3 } + +prvtLldpTransmitDelay OBJECT-TYPE + SYNTAX Unsigned32 (1..8192) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the minimum transmint delay interval (in [s])" + ::= { prvtLldpObjects 4 } + +prvtLldpTransmitHold OBJECT-TYPE + SYNTAX Unsigned32 (2..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the transmit-hold parameter" + ::= { prvtLldpObjects 5 } + +prvtLldpTransmitInterval OBJECT-TYPE + SYNTAX Unsigned32 (5..32768) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the minimum transmint interval (in [s])" + ::= { prvtLldpObjects 6 } + +prvtLldpStatisticsObjects OBJECT IDENTIFIER + ::= { prvtLldpObjects 7 } + +prvtLldpStatsRemTablesLastChange OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time from last remote table change." + ::= { prvtLldpStatisticsObjects 1 } + +prvtLldpStatsRemTablesInserts OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries insterted in remote table" + ::= { prvtLldpStatisticsObjects 2 } + +prvtLldpStatsRemTablesDeletes OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries deleted in remote table" + ::= { prvtLldpStatisticsObjects 3 } + +prvtLldpStatsRemTablesDrops OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries dropped from remote table" + ::= { prvtLldpStatisticsObjects 4 } + +prvtLldpStatsRemTablesAgeouts OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries dropped from remote table" + ::= { prvtLldpStatisticsObjects 5 } + +prvtLldpStatsTxPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLldpStatsTxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing send LLDPDU from all ports." + ::= { prvtLldpObjects 8 } + +prvtLldpStatsTxPortEntry OBJECT-TYPE + SYNTAX PrvtLldpStatsTxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for send LLDPDU from given port." + INDEX { prvtLldpStatsTxIfNum } + ::= { prvtLldpStatsTxPortTable 1 } + +PrvtLldpStatsTxPortEntry ::= SEQUENCE { + prvtLldpStatsTxIfNum OCTET STRING, + prvtLldpStatsTxPortFramesTotal Unsigned32, + prvtLldpStatsTxPortFramesMalformed Unsigned32 +} + +prvtLldpStatsTxIfNum OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface name." + ::= { prvtLldpStatsTxPortEntry 1 } + +prvtLldpStatsTxPortFramesTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total LLDPDUs send from this interface" + ::= { prvtLldpStatsTxPortEntry 2 } + +prvtLldpStatsTxPortFramesMalformed OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Malformed LLDPDUs send from this interface" + ::= { prvtLldpStatsTxPortEntry 3 } + +prvtLldpStatsRxPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLldpStatsRxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing received LLDPDU from all ports." + ::= { prvtLldpObjects 9 } + +prvtLldpStatsRxPortEntry OBJECT-TYPE + SYNTAX PrvtLldpStatsRxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for received LLDPDU from given port." + INDEX { prvtLldpStatsRxIfNum } + ::= { prvtLldpStatsRxPortTable 1 } + +PrvtLldpStatsRxPortEntry ::= SEQUENCE { + prvtLldpStatsRxIfNum OCTET STRING, + prvtLldpStatsRxPortFramesDiscardedTotal Unsigned32, + prvtLldpStatsRxPortFramesErrors Unsigned32, + prvtLldpStatsRxPortFramesTotal Unsigned32, + prvtLldpStatsRxPortTLVsDiscardedTotal Unsigned32, + prvtLldpStatsRxPortTLVsUnrecognizedTotal Unsigned32, + prvtLldpStatsRxPortAgeoutsTotal Unsigned32 +} + +prvtLldpStatsRxIfNum OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface name." + ::= { prvtLldpStatsRxPortEntry 1 } + +prvtLldpStatsRxPortFramesDiscardedTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of discarded frames from port." + ::= { prvtLldpStatsRxPortEntry 2 } + +prvtLldpStatsRxPortFramesErrors OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of frame errors on port." + ::= { prvtLldpStatsRxPortEntry 3 } + +prvtLldpStatsRxPortFramesTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received frames from port." + ::= { prvtLldpStatsRxPortEntry 4 } + +prvtLldpStatsRxPortTLVsDiscardedTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of discarded TLVs from port" + ::= { prvtLldpStatsRxPortEntry 5 } + +prvtLldpStatsRxPortTLVsUnrecognizedTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of unrecognized TLVs from port." + ::= { prvtLldpStatsRxPortEntry 6 } + +prvtLldpStatsRxPortAgeoutsTotal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of age outs on port." + ::= { prvtLldpStatsRxPortEntry 7 } + +prvtLldpLocalSystemDataObjects OBJECT IDENTIFIER + ::= { prvtLldpObjects 10 } + +prvtLldpLocChassisIdSubtype OBJECT-TYPE + SYNTAX INTEGER { chassisComponent(1), interfaceAlias(2), + portComponent(3), macAddress(4), networkAddress(5), + interfaceName(6), local(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Subtype of the local Chasis" + ::= { prvtLldpLocalSystemDataObjects 1 } + +prvtLldpLocChassisId OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MAC address of the local chassis." + ::= { prvtLldpLocalSystemDataObjects 2 } + +prvtLldpLocSysName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local system name." + ::= { prvtLldpLocalSystemDataObjects 3 } + +prvtLldpLocSysDesc OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local system description." + ::= { prvtLldpLocalSystemDataObjects 4 } + +prvtLldpLocSysCapSupported OBJECT-TYPE + SYNTAX BITS { other(0), bridge(2), wlanAccessPoint(3), + router(4), telephone(5), docsisCableDevice(6), + stationOnly(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local system supported capabilities." + ::= { prvtLldpLocalSystemDataObjects 5 } + +prvtLldpLocSysCapEnabled OBJECT-TYPE + SYNTAX BITS { other(0), bridge(2), wlanAccessPoint(3), + router(4), telephone(5), docsisCableDevice(6), + stationOnly(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local system enabled capabilities." + ::= { prvtLldpLocalSystemDataObjects 6 } + +prvtLldpLocManAddrTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLldpLocManAddrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of local management addresses." + ::= { prvtLldpObjects 11 } + +prvtLldpLocManAddrEntry OBJECT-TYPE + SYNTAX PrvtLldpLocManAddrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Local management address entry" + INDEX { prvtLldpLocManAddrSubtype, prvtLldpLocManAddress } + ::= { prvtLldpLocManAddrTable 1 } + +PrvtLldpLocManAddrEntry ::= SEQUENCE { + prvtLldpLocManAddrSubtype INTEGER, + prvtLldpLocManAddress OCTET STRING, + prvtLldpLocManAddrLen Integer32, + prvtLldpLocManAddrIfSubtype INTEGER, + prvtLldpLocManAddrIfId Integer32, + prvtLldpLocManAddrOID OBJECT IDENTIFIER +} + +prvtLldpLocManAddrSubtype OBJECT-TYPE + SYNTAX INTEGER { other(0), ipV4(1), ipV6(2), nsap(3), hldc(4), + bbn1822(5), all802(6), e163(7), e164(8), f69(9), + x121(10), ipx(11), appletalk(12), decnetIV(13), + banyanVines(14), e164withNsap(15), dns(16), + distinguishedname(17), asnumber(18), xtpoveripv4(19), + xtpoveripv6(20), xtpnativemodextp(21), + reserved(65535) } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Subtype of local management address" + ::= { prvtLldpLocManAddrEntry 1 } + +prvtLldpLocManAddress OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..31)) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Local management address" + ::= { prvtLldpLocManAddrEntry 2 } + +prvtLldpLocManAddrLen OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lenght of local managemet address" + ::= { prvtLldpLocManAddrEntry 3 } + +prvtLldpLocManAddrIfSubtype OBJECT-TYPE + SYNTAX INTEGER { unknown(1), ifIndex(2), systemPortNumber(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Local management addres interface subtype" + ::= { prvtLldpLocManAddrEntry 4 } + +prvtLldpLocManAddrIfId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interface index of local management address" + ::= { prvtLldpLocManAddrEntry 5 } + +prvtLldpLocManAddrOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "" + ::= { prvtLldpLocManAddrEntry 6 } + +prvtLldpPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLldpPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of LLDP ports" + ::= { prvtLldpObjects 12 } + +prvtLldpPortEntry OBJECT-TYPE + SYNTAX PrvtLldpPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry for LLDP ports" + INDEX { prvtLldpCfgPortName } + ::= { prvtLldpPortTable 1 } + +PrvtLldpPortEntry ::= SEQUENCE { + prvtLldpCfgPortName OCTET STRING, + prvtLldpCfgPortRowStatus RowStatus, + prvtLldpCfgPortMode INTEGER, + prvtLldpCfgPortSnmpNotify TruthValue, + prvtLldpAdvBasicPortManAddr TruthValue, + prvtLldpAdvBasicPortDescr TruthValue, + prvtLldpAdvBasicPortSysCap TruthValue, + prvtLldpAdvBasicPortSysDescr TruthValue, + prvtLldpAdvBasicPortSysName TruthValue, + prvtLldpDot1PortVlanId TruthValue, + prvtLldpDot1PortProtoIdentity TruthValue, + prvtLldpDot1PortVlanName TruthValue, + prvtLldpDot1PortProtoVlanId TruthValue, + prvtLldpDot3PortLAG TruthValue, + prvtLldpDot3PortMacPhy TruthValue, + prvtLldpDot3PortMaxFrameSize TruthValue, + prvtLldpDot3PortPowerViaMdi TruthValue +} + +prvtLldpCfgPortName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface name." + ::= { prvtLldpPortEntry 1 } + +prvtLldpCfgPortRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The RowStatus entry for this interface." + ::= { prvtLldpPortEntry 2 } + +prvtLldpCfgPortMode OBJECT-TYPE + SYNTAX INTEGER { txOnly(1), rxOnly(2), rxTx(3), disabled(4) } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Set port admin status" + ::= { prvtLldpPortEntry 3 } + +prvtLldpCfgPortSnmpNotify OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Configure sending of LLDP SNMP notifications" + ::= { prvtLldpPortEntry 4 } + +prvtLldpAdvBasicPortManAddr OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify if LLDP will advertise the management addresses." + ::= { prvtLldpPortEntry 5 } + +prvtLldpAdvBasicPortDescr OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify if the description of the configured interface will be advertised by LLDP." + ::= { prvtLldpPortEntry 6 } + +prvtLldpAdvBasicPortSysCap OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify if system capabilities information (bitmap) will be sent to the interface being configured." + ::= { prvtLldpPortEntry 7 } + +prvtLldpAdvBasicPortSysDescr OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify if the system description will be sent to the interface being configured." + ::= { prvtLldpPortEntry 8 } + +prvtLldpAdvBasicPortSysName OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specify if the system name will be sent to the interface being configured" + ::= { prvtLldpPortEntry 9 } + +prvtLldpDot1PortVlanId OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Port VLAN-Id TLVs." + ::= { prvtLldpPortEntry 10 } + +prvtLldpDot1PortProtoIdentity OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Protocol Identity TLVs." + ::= { prvtLldpPortEntry 11 } + +prvtLldpDot1PortVlanName OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "VLAN Name TLVs." + ::= { prvtLldpPortEntry 12 } + +prvtLldpDot1PortProtoVlanId OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "VLAN ID TLVs." + ::= { prvtLldpPortEntry 13 } + +prvtLldpDot3PortLAG OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link-aggregation TLVs." + ::= { prvtLldpPortEntry 14 } + +prvtLldpDot3PortMacPhy OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Mac-phy TLVs." + ::= { prvtLldpPortEntry 15 } + +prvtLldpDot3PortMaxFrameSize OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Maximum Frame Size TLV." + ::= { prvtLldpPortEntry 16 } + +prvtLldpDot3PortPowerViaMdi OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Power-via-mdi TLV." + ::= { prvtLldpPortEntry 17 } + +prvtLldpRemDbPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF PrvtLldpRemDbPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing remote Db." + ::= { prvtLldpObjects 13 } + +prvtLldpRemDbPortEntry OBJECT-TYPE + SYNTAX PrvtLldpRemDbPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for received LLDPDU from given port." + INDEX { prvtLldpRemDbIfNum } + ::= { prvtLldpRemDbPortTable 1 } + +PrvtLldpRemDbPortEntry ::= SEQUENCE { + prvtLldpRemDbIfNum OCTET STRING, + prvtLldpRemDbPortDataTTL Integer32, + prvtLldpRemDbPortDataAge Integer32, + prvtLldpRemDbPortChasIdSub INTEGER, + prvtLldpRemDbPortChasId OCTET STRING, + prvtLldpRemDbPortIdSub INTEGER, + prvtLldpRemDbPortId PhysAddress, + prvtLldpRemDbPortSysName OCTET STRING, + prvtLldpRemDbPortSysDescr OCTET STRING, + prvtLldpRemDbPortDescr OCTET STRING, + prvtLldpRemDbPortSysCapSupported BITS, + prvtLldpRemDbPortSysCapEnabled BITS, + prvtLldpRemDbPortManAddr OCTET STRING +} + +prvtLldpRemDbIfNum OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface name." + ::= { prvtLldpRemDbPortEntry 1 } + +prvtLldpRemDbPortDataTTL OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote Data TTL" + ::= { prvtLldpRemDbPortEntry 2 } + +prvtLldpRemDbPortDataAge OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote Data Age" + ::= { prvtLldpRemDbPortEntry 3 } + +prvtLldpRemDbPortChasIdSub OBJECT-TYPE + SYNTAX INTEGER { chassisComponent(1), interfaceAlias(2), + portComponent(3), macAddress(4), networkAddress(5), + interfaceName(6), local(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Subtype of the Remote Chasis" + ::= { prvtLldpRemDbPortEntry 4 } + +prvtLldpRemDbPortChasId OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote Chassis ID" + ::= { prvtLldpRemDbPortEntry 5 } + +prvtLldpRemDbPortIdSub OBJECT-TYPE + SYNTAX INTEGER { interfaceAlias(1), portComponent(2), + macAddress(3), networkAddress(4), interfaceName(5), + agentCircuitId(6), local(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Subtype of the Remote Port" + ::= { prvtLldpRemDbPortEntry 6 } + +prvtLldpRemDbPortId OBJECT-TYPE + SYNTAX PhysAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote Port ID" + ::= { prvtLldpRemDbPortEntry 7 } + +prvtLldpRemDbPortSysName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote system name." + ::= { prvtLldpRemDbPortEntry 8 } + +prvtLldpRemDbPortSysDescr OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote system description." + ::= { prvtLldpRemDbPortEntry 9 } + +prvtLldpRemDbPortDescr OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote port description." + ::= { prvtLldpRemDbPortEntry 10 } + +prvtLldpRemDbPortSysCapSupported OBJECT-TYPE + SYNTAX BITS { other(0), bridge(2), wlanAccessPoint(3), + router(4), telephone(5), docsisCableDevice(6), + stationOnly(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote System supported capabilities." + ::= { prvtLldpRemDbPortEntry 11 } + +prvtLldpRemDbPortSysCapEnabled OBJECT-TYPE + SYNTAX BITS { other(0), bridge(2), wlanAccessPoint(3), + router(4), telephone(5), docsisCableDevice(6), + stationOnly(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote System enabled capabilities." + ::= { prvtLldpRemDbPortEntry 12 } + +prvtLldpRemDbPortManAddr OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote management address." + ::= { prvtLldpRemDbPortEntry 13 } + +lldpNewRemoteInfo NOTIFICATION-TYPE + OBJECTS { prvtLldpStatsRemTablesInserts, + prvtLldpStatsRemTablesDeletes, + prvtLldpStatsRemTablesDrops, + prvtLldpStatsRemTablesAgeouts } + STATUS current + DESCRIPTION + "New Remote Info" + ::= { prvtlldpNotifications 1 } + +END -- end of module PRVT-LLDP-MIB. -- cgit v1.2.3