From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- .../binos/PRVT-NETWORK-LOOPBACK-TEST-MIB | 210 +++++++++++++++++++++ 1 file changed, 210 insertions(+) create mode 100644 MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB (limited to 'MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB') diff --git a/MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB b/MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB new file mode 100644 index 0000000..c914b89 --- /dev/null +++ b/MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB @@ -0,0 +1,210 @@ +-- ********************************************************************* +-- ********************************************************************* +-- ** Filename: PRVT-NETWORK-LOOPBACK-TEST-MIB +-- ** Project: Network Loopback Tester +-- ** Purpose: Private MIB +-- ********************************************************************* +-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved. +-- WARNING: +-- +-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: +-- +-- This file is the property of BATM Advanced Communications. +-- BATM Advanced Communications retains all title and +-- ownership in the Specification, including any revisions. + +-- BATM Advanced Communications grants all interested parties a non-exclusive +-- license to use and distribute an unmodified copy of this +-- Specification in connection with management of BATM Advanced Communications +-- and Telco Systems products, and without fee, provided that the following +-- conditions are met: +-- 1. Redistributions of this specification must retain the above copyright +-- notice, this list of conditions and the following disclaimer. +-- 2. Redistributions in binary form must reproduce the above copyright +-- notice, this list of conditions and the following disclaimer in the +-- documentation and/or other materials provided with the distribution. +-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse +-- or promote products derived from this specification without specific prior written +-- permission. +-- +-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED +-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE +-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED +-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES +-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. +-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER +-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS +-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR +-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY +-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE. +PRVT-NETWORK-LOOPBACK-TEST-MIB DEFINITIONS ::= BEGIN + +IMPORTS +MODULE-IDENTITY, +OBJECT-TYPE +FROM SNMPv2-SMI + +ifIndex +FROM IF-MIB + +MODULE-COMPLIANCE, +OBJECT-GROUP, +NOTIFICATION-GROUP +FROM SNMPv2-CONF + +TimeStamp, +RowStatus +FROM SNMPv2-TC + +NOTIFICATION-TYPE +FROM SNMPv2-SMI -- [RFC2578] + + +accessListControlListGroup +FROM PRVT-SWITCH-ACCESS-LIST-MIB + +ipSwitch FROM PRVT-SWITCH-MIB; + +-- The NETWORK LOOPBACK TEST MIB +prvtNetworkLoopbackTestMib MODULE-IDENTITY + +LAST-UPDATED "201008310000Z" +ORGANIZATION "BATM Advanced Communication" +CONTACT-INFO +"BATM/Telco Systems Support team +Email: +For North America: techsupport@telco.com +For North Europe: support@batm.de, info@batm.de +For the rest of the world: techsupport@telco.com" + +DESCRIPTION +"This MIB contains managed objects definitions for +encapsulating Loopback Tester feature that enables or disables +embedded mechanisms for network troubleshooting, diagnostics and measurement." + +REVISION "201008310000Z" +DESCRIPTION +"Initial version." + +::= { ipSwitch 7 } + +prvtNetworkLoopbackTestNotifications OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 0 } +prvtNetworkLoopbackTestObjects OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 1 } +prvtNetworkLoopbackTestConformance OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 2 } + +prvtNetworkLoopbackTestTable OBJECT-TYPE +SYNTAX SEQUENCE OF PrvtNetworkLoopbackTestEntry +MAX-ACCESS not-accessible +STATUS current +DESCRIPTION +"This table contains object for configuring and display information about Network Loopback Tester." +::= { prvtNetworkLoopbackTestObjects 1 } + +prvtNetworkLoopbackTestEntry OBJECT-TYPE +SYNTAX PrvtNetworkLoopbackTestEntry +MAX-ACCESS not-accessible +STATUS current +DESCRIPTION +"An entry in the prvtNetworkLoopbackTestTable table" +INDEX { ifIndex, accessListControlListGroup } +::= { prvtNetworkLoopbackTestTable 1 } + +PrvtNetworkLoopbackTestEntry ::= SEQUENCE { +prvtNetworkLoopTestDuration INTEGER, +prvtNetworkLoopStartDuration TimeStamp, +prvtNetworkLoopEndDuration TimeStamp, +prvtNetworkLoopRowStatus RowStatus +} + +prvtNetworkLoopTestDuration OBJECT-TYPE +SYNTAX INTEGER (0..100000) +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"An integer that identifies the duration in seconds of Loopback test. +For infinite Loopback tests object will have the value 0." +::= {prvtNetworkLoopbackTestEntry 1} + +prvtNetworkLoopStartDuration OBJECT-TYPE +SYNTAX TimeStamp +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Star time of Loopback test. +For infinite Loopback tests object will have the value 0." +::= {prvtNetworkLoopbackTestEntry 2} + +prvtNetworkLoopEndDuration OBJECT-TYPE +SYNTAX TimeStamp +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"End time of Loopback test. +For infinite Loopback tests object will have the value 0." +::= {prvtNetworkLoopbackTestEntry 3} + +prvtNetworkLoopRowStatus OBJECT-TYPE +SYNTAX RowStatus +MAX-ACCESS read-create +STATUS current +DESCRIPTION +"Network Loopback Test RowStatus. + Both createAndGo(4) and createAndWait(5) are available. + CreateAndGo(4) is used for enable a Loopback test unlimited in time and CreateAndWait(4) + for enable a Loopback Test on a period specified by prvtNetworkLoopTestDuration." +::= {prvtNetworkLoopbackTestEntry 4} + +-- ---------------------------------------------------------------------------- +-- Notifications +-- ---------------------------------------------------------------------------- + +prvtNetworkLoopbackTestFinish NOTIFICATION-TYPE +OBJECTS { ifIndex, accessListControlListGroup } +STATUS current +DESCRIPTION +"This notification is sent when a Network Loopback Test is complete." +::= {prvtNetworkLoopbackTestNotifications 1} + +-- ---------------------------------------------------------------------------- +-- Conformance Information +-- ---------------------------------------------------------------------------- +prvtNetworkLoopTestCompliances OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 1} +prvtNetworkLoopTestGroups OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 2} + +-- compliance statements +prvtNetworkLoopTestCompliance MODULE-COMPLIANCE +STATUS current +DESCRIPTION +"The compliance statement for Network Loopback Tester." +MODULE -- this module +MANDATORY-GROUPS { +prvtNetworkLoopTestGroup, +prvtNetworkLoopTestNotificationsGroup +} +::= {prvtNetworkLoopTestCompliances 1} + +prvtNetworkLoopTestGroup OBJECT-GROUP +OBJECTS {prvtNetworkLoopTestDuration, +prvtNetworkLoopStartDuration, +prvtNetworkLoopEndDuration, +prvtNetworkLoopRowStatus +} +STATUS current +DESCRIPTION +"The group of objects regarding Network Looback Tester feature." +::= {prvtNetworkLoopTestGroups 1} + +prvtNetworkLoopTestNotificationsGroup NOTIFICATION-GROUP +NOTIFICATIONS{ +prvtNetworkLoopbackTestFinish +} +STATUS current +DESCRIPTION +"The collection of Notifications used to indicate general status information + of Network Looback Tester feature." +::= {prvtNetworkLoopTestGroups 2} + +END + + + -- cgit v1.2.3