From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB | 839 ++++++++++++++++++++++ 1 file changed, 839 insertions(+) create mode 100644 MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB (limited to 'MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB') diff --git a/MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB b/MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB new file mode 100644 index 0000000..32d9a29 --- /dev/null +++ b/MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB @@ -0,0 +1,839 @@ +-- ********************************************************************* +-- ** +-- ** BATM Advanced Communications. +-- ** +-- ********************************************************************* +-- ** Filename: prvt-interworking-os-mib.mib +-- ********************************************************************* +-- (c) Copyright, 1998, BATM Advanced Communications. All rights reserved. +-- WARNING: +-- +-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: +-- +-- This file is the property of BATM Advanced Communications and contains +-- proprietary and confidential information. This file is made +-- available to authorized BATM customers on the express +-- condition that neither it, nor any of the information contained +-- therein, shall be disclosed to third parties or be used for any +-- purpose other than to replace, modify or upgrade firmware and/or +-- software components of BATM manufactured equipment within the +-- authorized customer's network, and that such transfer be +-- completed in accordance with the instructions provided by +-- BATM. Any other use is strictly prohibited. +-- +-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED +-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE +-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED +-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES +-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. +-- +-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER +-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS +-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR +-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY +-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. +-- +-- ---------------------------------------------------------------------------- +-- +PRVT-INTERWORKING-OS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + +MODULE-IDENTITY, +OBJECT-TYPE, +IpAddress, +Integer32 +FROM SNMPv2-SMI + +DisplayString, +TruthValue, +MacAddress +FROM SNMPv2-TC + +NOTIFICATION-TYPE +FROM SNMPv2-SMI + +prvt-products +FROM PRVT-SWITCH-MIB + +usmUserSecurityName +FROM SNMP-USER-BASED-SM-MIB; + +prvtInterworkOsMib MODULE-IDENTITY +LAST-UPDATED "200804090000Z" +ORGANIZATION "BATM Advanced Communication" +CONTACT-INFO +"BATM/Telco Systems Support team +Email: +For North America: techsupport@telco.com +For North Europe: support@batm.de, info@batm.de +For the rest of the world: techsupport@telco.com" + +DESCRIPTION +"The MIB enables display configuration of the device OS features." + +-- revision history +REVISION "200804090000Z" +DESCRIPTION +"setExecutetrap varbind change" +REVISION "200803310000Z" +DESCRIPTION +"Removed configurationChanged, see PrvtConfigChange.mib." + +REVISION "200801010000Z" +DESCRIPTION +"Removed redefined OIDs in private vendor extension definitions." + +REVISION "200502160000Z" +DESCRIPTION +"Fixed spelling errors and changed the contact info." + +REVISION "200412200000Z" +DESCRIPTION +"Added the configurationChanged and snmpSetExecuted notifications." + +REVISION "200403100000Z" +DESCRIPTION +"Modified the description of the managementLoadExecute object +to clarify that the startup-config is replaced at +configuration download." + + +REVISION "200305080000Z" +DESCRIPTION +"Move to SMI-V2." + +REVISION "200212120000Z" +DESCRIPTION +"Add detection for CPU RAM size." + +REVISION "200211260000Z" +DESCRIPTION +"Add CPU group." + + +REVISION "200211170000Z" +DESCRIPTION +"Enable loading VDSL E2 firmware. +Add support for reload." + +REVISION "200104190000Z" +DESCRIPTION +"Add management group." + +REVISION "200103190000Z" +DESCRIPTION +"Initial version." + +::= { software 1 } + +software OBJECT IDENTIFIER ::= { prvt-products 111 } + +prvtInterworkOsNotifications OBJECT IDENTIFIER ::= { prvtInterworkOsMib 0 } +version OBJECT IDENTIFIER ::= {prvtInterworkOsMib 1} +option OBJECT IDENTIFIER ::= {prvtInterworkOsMib 2} +management OBJECT IDENTIFIER ::= {prvtInterworkOsMib 3} +cpu OBJECT IDENTIFIER ::= {prvtInterworkOsMib 4} +prvtInterworkOsConformance OBJECT IDENTIFIER ::= { prvtInterworkOsMib 5 } + +-- +-- version group +-- + +bootVersionNumber OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object identifies version number of the Boot program" +::= { version 1 } + +bootVersionDate OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object identifies creation date/time of the Boot program" +::= { version 2 } + +bootVersionString OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object contains text for the current version of the Boot program" +::= { version 3 } + +oSversionNumber OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object identifies version number of the OS" +::= { version 4 } + +oSversionDate OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object identifies creation date/time of the OS" +::= { version 5 } + +oSversionString OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object contains text for the current version of the OS" +::= { version 6 } + +appletVersionNumber OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object contains text for the current version of the embedded +applet" +::= { version 7 } + +appletVersionDate OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object contains text for the creation date of the current embedded +applet version" +::= { version 8 } +-- +-- option group +-- + +optionInstalled OBJECT-TYPE +SYNTAX OCTET STRING +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object identifies creation date/time of the OS" +::= { option 1 } + +-- +-- management group +-- + +-- +-- Connectivity Information +-- +-- This group is meant to be a collection of controls and data +-- for connectivity. +-- +managementConnectivity OBJECT IDENTIFIER ::= {management 1} + +managementConnectivityMACAddr OBJECT-TYPE +SYNTAX MacAddress +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Get the agent MAC address." +::= { managementConnectivity 1 } + +managementConnectivityIpAddress OBJECT-TYPE +SYNTAX IpAddress +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Set IP Address for the device." +::= { managementConnectivity 2 } + +managementConnectivityIPNetMask OBJECT-TYPE +SYNTAX IpAddress +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Set IP NetMask for the device." +::= { managementConnectivity 3 } + +managementIPGateAddress OBJECT-TYPE +SYNTAX IpAddress +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Set Gateway Address for the device - only applies for devices without +L3 capabilities." +::= { managementConnectivity 4 } + +managementSerialBaud OBJECT-TYPE +SYNTAX INTEGER { +baud2400(1), +baud9600(2), +baud19200(3), +baud38400(4) +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"The Serial port BAUD Rate. Attributes are 8 Start Bits, +no parity, and 1 stop bits (8N1) and Hardware Flow Control. +Valid values are 2400, 9600, 19200, and 38400." +::= { managementConnectivity 5 } + +-- +-- managementLoad Group +-- +-- This group is meant to be a collection of controls and data +-- that determine the file download and upload configuration +-- and mode. +-- + +managementLoad OBJECT IDENTIFIER ::= {management 2} + +managementLoadTftpServerAddress OBJECT-TYPE +SYNTAX IpAddress +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Set IP Address for the TFTP server used for downloading +and uploading files." +::= { managementLoad 1 } + +managementLoadFileName OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (0..64)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Set TFTP file path and name." +::= { managementLoad 2 } + +managementLoadType OBJECT-TYPE +SYNTAX INTEGER { +application(1), +boot(2), +configuration(3), +java(4), +vdsl-E2(5) +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"The type of file to download or upload +upon a managementLoadExecute." +::= { managementLoad 3 } + +managementLoadExecute OBJECT-TYPE +SYNTAX INTEGER { +noop(1), -- no operation +download(2), -- Application, Boot, java or Configuration +upload(3) -- Configuration only +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Execute file download or upload procedure. A SET of this +object starts the load procedure. Note that the Application +and Boot images can only be downloaded. The Configuration +file can be uploaded and downloaded. When a Configuration file +is downloaded, it replaces the startup-config file in NVRAM. + +A GET of this object will return a noop (1). Also, when the user chooses to +upload the configuration, it is the startup-config that is copied to the remote host. +Use managementLoadExecuteStatus to determine the status of the executed load." +::= { managementLoad 4 } + +managementLoadExecuteStatus OBJECT-TYPE +SYNTAX INTEGER { +not-started(1), +in-progress(2), +success(3), +error-connection(4), +error-filename(5), +error-fault(6) +} +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Provides status on the execute file load procedure. +The status return is given by one of the enumerated codes +not-started (download has not yet started) +in-progress (download has not yet finished) +success (download has finished successfully) +error-connection (download cannot connect) +error-filename (download has bad image path/filename) +error-fault (download has fault condition on device)." +::= { managementLoad 5 } + +-- +-- Miscellaneous Information +-- +-- This group is meant to be a collection of controls and data +-- that do not require a group of their own, or fall into the +-- category of "miscellaneous". +-- + +managementMisc OBJECT IDENTIFIER ::= {management 3} + +managementMiscSaveToNvm OBJECT-TYPE +SYNTAX INTEGER { +noop(1), -- no operation +save(2) -- save all configuration parameters to NVM +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"When set to save (2), all nonvolatile configuration +parameters are saved to NVM (Nonvolatile Memory). NVM save +operations may be slow (e.g., erasing/writing Flash device). +Consequently, all (or many) updates should be made before +saving to NVM. A get operation always returns noop (1)" +::= { managementMisc 1 } + +managementMiscReset OBJECT-TYPE +SYNTAX INTEGER { +noop(1), +reset(2), +reset-to-defaults(3), +save-and-reset(4) -- save config and then reset the unit +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Physically performs a hardware reset of the unit. +Use with care. A reset (2) resets the unit, the +reset-to-defaults (3) resets the configuration file +to factory defaults and then resets the unit, the value of +save-and-reset (4) saves the config and then resets the unit and +noop (1) does nothing. +A value of noop (1) is always returned +for a GET operation." +::= { managementMisc 2 } + +managementMiscReload OBJECT-TYPE +SYNTAX INTEGER { +noop(1), +save-and-reload(2) -- save config and then reload the software +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Reload the unit software, the unit hardware will not +be affected. A value of noop (1) is always returned for a +GET operation." +::= { managementMisc 3 } + +managementMiscReloadInTime OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (4)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION "Indicates time for scheduled reload without save in hour:min. +octets contents range +1 day 0x01..0x1f (1-31) +2 month 0x01..0x0C (1..12) +where january = 1 december = 12 +3 hour 0x01..0x17 (0..23) +4 min 0x01..3B (0..59) +For example: 0x01 0x01 0x01 0x01 means 1 January 01:01. +To stop scheduled reload set it to 0x00 0x00 0x00 0x00" +::= { managementMisc 4 } + +managementMiscReloadAtTime OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (4)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION "Indicates time for scheduled reload without save at day:month:hour:min. +octets contents range +1 day 0x01..0x1f (1-31) +2 month 0x01..0x0C (1..12) +where january = 1 december = 12 +3 hour 0x01..0x17 (0..23) +4 min 0x01..3B (0..59) +For example: 0x01 0x01 0x01 0x01 means 1 January 01:01. +To stop scheduled reload set it to 0x00 0x00 0x00 0x00" +::= { managementMisc 5 } + +managementMiscReloadSaveInTime OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (4)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION "Indicates time for scheduled reload with save in hour:min. +octets contents range +1 day 0x01..0x1f (1-31) +2 month 0x01..0x0C (1..12) +where january = 1 december = 12 +3 hour 0x01..0x17 (0..23) +4 min 0x01..3B (0..59) +For example: 0x01 0x01 0x01 0x01 means 1 January 01:01. +To stop scheduled reload set it to 0x00 0x00 0x00 0x00" +::= { managementMisc 6 } + +managementMiscReloadSaveAtTime OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (4)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION "Indicates time for scheduled reload with save at day:month:hour:min. +octets contents range +1 day 0x01..0x1f (1-31) +2 month 0x01..0x0C (1..12) +where january = 1 december = 12 +3 hour 0x01..0x17 (0..23) +4 min 0x01..3B (0..59) +For example: 0x01 0x01 0x01 0x01 means 1 January 01:01. +To stop scheduled reload set it to 0x00 0x00 0x00 0x00" +::= { managementMisc 7 } + +managementLicense OBJECT IDENTIFIER ::= {management 4} + +managementOptionSupportStatus OBJECT-TYPE +SYNTAX INTEGER { reserved0 (0), -- reserved +reserved1 (1), -- reserved +reserved2 (2), -- reserved +reserved3 (3), -- reserved +reserved4 (4), -- reserved +reserved5 (5), -- reserved +reserved6 (6), -- reserved +reserved7 (7), -- reserved +reserved8 (8), -- reserved +reserved9 (9), -- reserved +licNotSpecified(10), -- the device is without license +licBasic(11), -- SWITCH license registered +licML(12), -- ML license +licAdvML(13), -- Adv-ML license +reserved14 (14), -- reserved +reserved15 (15), -- reserved +reserved16 (16), -- reserved +reserved17 (17), -- reserved +reserved18 (18), -- reserved +reserved19 (19), -- reserved +reserved20 (20), -- reserved +reserved21 (21), -- reserved +reserved22 (22), -- reserved +reserved23 (23), -- reserved +reserved24 (24), -- reserved +reserved25 (25), -- reserved +reserved26 (26), -- reserved +reserved27 (27), -- reserved +reserved28 (28), -- reserved +reserved29 (29), -- reserved +reserved30 (30), -- reserved +reserved31 (31) -- reserved +} +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Indicates active software support options (license)." +::= { managementLicense 1 } + +managementOptionSupportKey OBJECT-TYPE +SYNTAX OCTET STRING (SIZE (0..32)) +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"Specify the software support option key (license). After set, device must be reloaded the new option to take affect." +::= { managementLicense 2 } + +managementOptionSupportAddress OBJECT-TYPE +SYNTAX IpAddress +MAX-ACCESS accessible-for-notify +STATUS current +DESCRIPTION +"Shows the address of SNMP NMS that has configured last the option." +::= { managementLicense 3 } + +managementOptionSupportL3Capable OBJECT-TYPE +SYNTAX TruthValue +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Indicates if the swicth is capable for L3 features +- true The switch is capable for L3 features +- false The switch is not capable for L3 features +" +DEFVAL { true } +::= { managementLicense 4 } + +prvtBootConfigUpgrade OBJECT IDENTIFIER ::= {management 5} + +prvtBootUpgradeSrcURI OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"The object represents an address from where the application +will be copied and used by the device. The address +must be given in a valid URI format. It will be used by all +booting mechnisms as a source from where to find the application. +So it can point to either local folder or remote device. + +Example: +tftp://10.3.71.45/MyApps/Imagev1.5.Z +local://Usr/Imagev1.5.Z + +If there is no value set, the device will boot with local application +given in prvtBootApplicationNameURI object" +REFERENCE "See rfc3986" +::= { prvtBootConfigUpgrade 1 } + +prvtBootApplicationNameURI OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"This object represents the name of the application to be used by +the network device to boot. The name of the application is given +in URI format to indicate the storage device. Every network device +can have few localy saved application files copied in different +storage devices: local file system, flash etc. The user can choose +one of them by setting the starage device and the application name. + +Example: +local://Imagev1.5.Z, +flash://Imagev1.5.Z + +If this object is empty, the device will boot from the network using +the remote application given in prvtBootUpgradeSrcURI" +REFERENCE "See rfc3986" +::= { prvtBootConfigUpgrade 2 } + +prvtBootConfigURI OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"This object represents the configuration file's name of a network device. +The value must be set in URI format. It can point to either local or remote +configuration file. + +Example: +local://Usr/my_startup.cfg, +ftp://myuser:mypass@netaddress/MyCfgs/startup.cfg + +This field is optional. If it is empty, the standart startup config will be used." +REFERENCE "See rfc3986" +::= { prvtBootConfigUpgrade 3 } + +prvtBootUpgradeCmd OBJECT-TYPE +SYNTAX INTEGER { +none(0), -- this will be invalid value +ready(1), -- the common return value on get and next requests +apply(2), +applyExec(3) +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"This field is used to apply the configuration. When a get request is +executed, the returned value should be always ready. When apply(2) +command is executed, the upgrade settings are applied. Alternative, +when applyExec(3) command is executed, the upgrade process is started. +" +DEFVAL { ready } +::= { prvtBootConfigUpgrade 4 } + +prvtBootOperStatus OBJECT-TYPE +SYNTAX INTEGER { +unknown(0), -- invalid value +ready(1), +notReady(2), +upgradeInProgress(3) +} +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"The object is used to show the current status of the upgrating process. The +default value is ready(1), indicating that the process is idle. when the value +is set to notReady(2), the device upgrading mechanism is not correctly configured. +upgradeInProgress(3) indicates upgrading process have started and haven't finished +yet." +DEFVAL { ready } +::= { prvtBootConfigUpgrade 5 } + +prvtBootErrorCondition OBJECT-TYPE +SYNTAX INTEGER { +noError(0), +genericError(1), +copyFailed(2), +downloadFailed(3), +freeSpaceError(4), +validationFailed(5), +backupFailed(6), +inProgressError(7), +consistencyError(8), +fileSystemError(9), +profileNameError(10), +profileError(11), +fileNameError(12), +pathError(13), +zFileError(14), +cannotFindFile(15), +defApplicationProfileError(16), +configProfileError(17), +bootDevProfileError(18), +ftpServerProfileError(19), +ftpUserProfileError(20), +ftpPassProfileError(21) +} +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"The object can be used for feedback. How the upgrading process have finished" +DEFVAL{ noError } +::= { prvtBootConfigUpgrade 6 } + + +-- +-- CPU group +-- + +cpuMonitoring OBJECT IDENTIFIER ::= {cpu 1} + +cpuMonitoringStatus OBJECT-TYPE +SYNTAX INTEGER { +enable(1), +disable(2) +} +MAX-ACCESS read-write +STATUS current +DESCRIPTION +"The object shows the status of the CPU monitor" +::= { cpuMonitoring 1 } + +cpuMonitoringUtilization OBJECT-TYPE +SYNTAX Integer32 +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"The object shows the current CPU utilization" +::= { cpuMonitoring 2 } + +cpuRedundancy OBJECT IDENTIFIER ::= {cpu 2} + +cpuHwRedundancySupport OBJECT-TYPE +SYNTAX TruthValue +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object shows if the backplan of this unit support CPU redundancy." +::= { cpuRedundancy 1 } + +cpuRedundancyTable OBJECT-TYPE +SYNTAX SEQUENCE OF CpuRedundancyEntry +MAX-ACCESS not-accessible +STATUS current +DESCRIPTION +"This table contains the CPU redundancy information." +::= { cpuRedundancy 2 } + +cpuRedundancyEntry OBJECT-TYPE +SYNTAX CpuRedundancyEntry +MAX-ACCESS not-accessible +STATUS current +DESCRIPTION +"Information about one CPU" +INDEX { cpuId } +::= { cpuRedundancyTable 1 } + +CpuRedundancyEntry ::= SEQUENCE { +cpuId Integer32, +cpuName DisplayString, +cpuStatus INTEGER, +cpuRedundancySupport TruthValue, +cpuSWVersionString DisplayString +} + +cpuId OBJECT-TYPE +SYNTAX Integer32 (0..256) +MAX-ACCESS not-accessible +STATUS current +DESCRIPTION +"The ID of the CPU in the system" +::= { cpuRedundancyEntry 1 } + +cpuName OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"Textual representation of the CPU" +::= { cpuRedundancyEntry 2 } + +cpuStatus OBJECT-TYPE +SYNTAX INTEGER { +active(1), +standby(2) +} +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"The CPU status" +::= { cpuRedundancyEntry 3 } + +cpuRedundancySupport OBJECT-TYPE +SYNTAX TruthValue +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object shows if the CPU card supports redundancy." +::= { cpuRedundancyEntry 4 } + +cpuSWVersionString OBJECT-TYPE +SYNTAX DisplayString +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"The OS version currently running on the CPU" +::= { cpuRedundancyEntry 5 } + +cpuHW OBJECT IDENTIFIER ::= {cpu 3} + +cpuRAMsize OBJECT-TYPE +SYNTAX Integer32 +MAX-ACCESS read-only +STATUS current +DESCRIPTION +"This object returns the CPU card RAM size" +::= { cpuHW 1 } + +-- Notifications for use by prvtInterworkOsMib + + +imageCrcCheckFailed NOTIFICATION-TYPE +OBJECTS { managementLoadTftpServerAddress, managementLoadFileName} +STATUS current +DESCRIPTION +"The imageCrcCheckFailed notification indicates that the +image loaded via TFTP has not passed the CRC check +and has been discarded." +::= {prvtInterworkOsNotifications 1} + +configurationLoadFailed NOTIFICATION-TYPE +OBJECTS { managementLoadTftpServerAddress, managementLoadFileName} +STATUS current +DESCRIPTION +"The configurationLoadFailed notification indicates that +the sending agent did not succeed to upload or download +the configuration file." +::= {prvtInterworkOsNotifications 2} + +unauthorizedAccessViaCLI NOTIFICATION-TYPE +-- OBJECTS { } +STATUS current +DESCRIPTION +"The unauthorizedAccessViaCLI notification indicates that +the last attempt to login to the device via CLI cannot +be authorized." +::= {prvtInterworkOsNotifications 3} + +snmpSetExecuted NOTIFICATION-TYPE +OBJECTS { usmUserSecurityName } +STATUS current +DESCRIPTION +"This notification indicates that a successful set request has been performed." +::= {prvtInterworkOsNotifications 4} + +managementOptionSupportChanged NOTIFICATION-TYPE +OBJECTS { managementOptionSupportStatus, managementOptionSupportAddress} +STATUS current +DESCRIPTION +"This notification indicates that a management option license has been changed." +::= {prvtInterworkOsNotifications 5} + +END + -- cgit v1.2.3