From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/riello/RIELLOMTS-MIB | 592 ++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 592 insertions(+) create mode 100644 MIBS/riello/RIELLOMTS-MIB (limited to 'MIBS/riello/RIELLOMTS-MIB') diff --git a/MIBS/riello/RIELLOMTS-MIB b/MIBS/riello/RIELLOMTS-MIB new file mode 100644 index 0000000..eca8691 --- /dev/null +++ b/MIBS/riello/RIELLOMTS-MIB @@ -0,0 +1,592 @@ +-- RPS S.p.A enterprise MIB definition + +-- Copyright (c) RPS S.p.A. +-- Version: 1.0.1 by Michele Marcon +-- Date: 07.06.2017 + +-- Title: RIELLOMTS-MIB + +-- MDU-MIB { iso org(3) dod(6) internet(1) private(4) +-- enterprises(1) riello(5491) } + +-- ************************************************************************ +-- ************************************************************************ + +RIELLOMTS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + DisplayString + FROM RFC1213-MIB + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215 + rielloMIB + FROM RIELLO-MIB; + + +mtsMIB OBJECT IDENTIFIER ::= { rielloMIB 12 } + +mtsIdent OBJECT IDENTIFIER ::= { mtsMIB 1 } + +mtsIdentManufacturer OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the mts manufacturer." + ::= { mtsIdent 1 } + +mtsIdentModel OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts Model designation." + ::= { mtsIdent 2 } + +mtsIdentSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts Software version." + ::= { mtsIdent 3 } + +mtsIdentIOConfiguration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts input/output configuration (1 for Mono/mono, 4 for Tri/tri)." + ::= { mtsIdent 4 } + +mtsIdentType OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts type (5 for ATS, 6 for STS)." + ::= { mtsIdent 5 } + +mtsIdentInputSockets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of mts input sockets." + ::= { mtsIdent 6 } + +mtsIdentOutputSockets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of mts output sockets." + ::= { mtsIdent 7 } + +mtsIdentNominalCurrent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts nominal current (A)." + ::= { mtsIdent 8 } + +mtsIdentNominalVoltage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts nominal voltage (V)." + ::= { mtsIdent 9 } + +mtsIdentNominalFrequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The mts nominal frequency (0.1 Hz)." + ::= { mtsIdent 10 } + +mtsStatus OBJECT IDENTIFIER ::= { mtsMIB 2 } + +mtsS1Frequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency of source 1 (0.1 Hz)." + ::= { mtsStatus 1 } + +mtsS1VoltageL1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 1, line 1 (V)." + ::= { mtsStatus 2 } + +mtsS1VoltageL2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 1, line 2 (V)." + ::= { mtsStatus 3 } + +mtsS1VoltageL3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 1, line 3 (V)." + ::= { mtsStatus 4 } + +mtsS2Frequency OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The frequency of source 2 (0.1 Hz)." + ::= { mtsStatus 5 } + +mtsS2VoltageL1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 2, line 1 (V)." + ::= { mtsStatus 6 } + +mtsS2VoltageL2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 2, line 2 (V)." + ::= { mtsStatus 7 } + +mtsS2VoltageL3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The voltage of source 2, line 3 (V)." + ::= { mtsStatus 8 } + +mtsPhaseDifference OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Phase difference between sources (degrees)." + ::= { mtsStatus 9 } + +mtsLoadL1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load of line 1 (%)." + ::= { mtsStatus 10 } + +mtsLoadL2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load of line 2 (%)." + ::= { mtsStatus 11 } + +mtsLoadL3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load of line 3 (%)." + ::= { mtsStatus 12 } + +mtsOutputCurrentL1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load current of line 1 (0.1 A)." + ::= { mtsStatus 13 } + +mtsOutputCurrentL2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load current of line 2 (0.1 A)." + ::= { mtsStatus 14 } + +mtsOutputCurrentL3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The output load current of line 3 (0.1 A)." + ::= { mtsStatus 15 } + +mtsTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature (degrees C)." + ::= { mtsStatus 16 } + +mtsSoundOff OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= sound on, 0= sound off." + ::= { mtsStatus 17 } + +mtsTestInProgress OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= test in progress, 0= test not in progress." + ::= { mtsStatus 18 } + +mtsAuxPower2fail OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= fail, 0= not fail." + ::= { mtsStatus 19 } + +mtsAuxPower1fail OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= fail, 0= not fail." + ::= { mtsStatus 20 } + +mtsSynchrobad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= bad, 0= not bad." + ::= { mtsStatus 21 } + +mtsPreferredSource OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= S2, 0= S1." + ::= { mtsStatus 22 } + +mtsTransferhinibit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= hinibit, 0= not hinibit." + ::= { mtsStatus 23 } + +mtsNonSynchInibit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 24 } + +mtsSourceS2bad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= bad, 0= not bad." + ::= { mtsStatus 25 } + +mtsSourceS1bad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= bad, 0= not bad." + ::= { mtsStatus 26 } + +mtsOnSourceS2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 27 } + +mtsOnSourceS1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 28 } + +mtsLocked OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= locked, 0= not locked." + ::= { mtsStatus 29 } + +mtsOutputSwitchOff OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 30 } + +mtsS2Blackout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= blackout, 0= no blackout." + ::= { mtsStatus 31 } + +mtsS2PhaseseqNotok OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 32 } + +mtsS2VoltOutoftolerance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 33 } + +mtsS1SCRAlternateLoss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 34 } + +mtsS1InputSWOff OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 35 } + +mtsS1Frequencybad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= bad, 0= not bad." + ::= { mtsStatus 36 } + +mtsS1Balancebad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 37 } + +mtsS1Blackout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 38 } + +mtsS1PhaseseqNotok OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 39 } + +mtsS1VoltOutoftolerance OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 40 } + +mtsUserlogin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 41 } + +mtsAlarmTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 42 } + +mtsAlarmOverload OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 43 } + +mtsGeneralFailure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 44 } + +mtsS2InputMCCBtrip OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 45 } + +mtsS1InputMCCBtrip OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 46 } + +mtsServicelogin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 47 } + +mtsOutputSCRalternanceloss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 48 } + +mtsManBypassS2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 49 } + +mtsManBypassS1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 50 } + +mtsManTransferS2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 51 } + +mtsManTransferS1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 52 } + +mtsS2SCRalternanceloss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 53 } + +mtsS2InputSWoff OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 54 } + +mtsS2Frequencybad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 55 } + +mtsS2Balancebad OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1= yes, 0= no." + ::= { mtsStatus 56 } + + +mtsTraps OBJECT IDENTIFIER ::= { mtsMIB 4 } + + +mtsNormal TRAP-TYPE + ENTERPRISE mtsTraps + DESCRIPTION "This trap is sent when STS is on normal status" + ::= 1 + +mtsAnomaly TRAP-TYPE + ENTERPRISE mtsTraps + DESCRIPTION "This trap is sent when STS is has some anomaly and is resent every minute" + ::= 2 + +mtsFault TRAP-TYPE + ENTERPRISE mtsTraps + DESCRIPTION "This trap is sent when STS is has some fault and is resent every minute" + ::= 3 + +mtsLock TRAP-TYPE + ENTERPRISE mtsTraps + DESCRIPTION "This trap is sent when STS is locked and is resent every minute" + ::= 4 + +mtsManualBypassEnabled TRAP-TYPE + ENTERPRISE mtsTraps + DESCRIPTION "This trap is sent when STS is on manual bypass and is resent every minute" + ::= 5 + +END + -- cgit v1.2.3