From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/raisecom/RAISECOM-FANMONITOR-MIB | 292 ++++++++++++++++++++++++++++++++++ 1 file changed, 292 insertions(+) create mode 100644 MIBS/raisecom/RAISECOM-FANMONITOR-MIB (limited to 'MIBS/raisecom/RAISECOM-FANMONITOR-MIB') diff --git a/MIBS/raisecom/RAISECOM-FANMONITOR-MIB b/MIBS/raisecom/RAISECOM-FANMONITOR-MIB new file mode 100644 index 0000000..1e7aea3 --- /dev/null +++ b/MIBS/raisecom/RAISECOM-FANMONITOR-MIB @@ -0,0 +1,292 @@ +-- MibName=raisecomSynce +-- ***************************************************************** +-- Version 1.0 Created 2010.12.30 by hongding +-- This version of MIB is created just for the Management of fan . +-- +-- Copyright(c) 2002-2012 by RAISECOM TECH, Ltd. +-- All rights reserved. +-- +-- modify history +-- 01,20120418,yangzhonghong, ITS00020700,change the enum values of the raisecomFanCardState node +-- 01,20121206,guokai, ESW00006977,add raisecomFanMonitorTrapSendEnable +-- ***************************************************************** +RAISECOM-FANMONITOR-MIB DEFINITIONS ::= BEGIN + +IMPORTS + raisecomSystem + FROM RAISECOM-SYSTEM-MIB + TruthValue + FROM SNMPv2-TC + Integer32,Unsigned32,Counter32 + FROM SNMPv2-SMI; + + raisecomFanMonitor MODULE-IDENTITY + LAST-UPDATED "201012270000Z" + ORGANIZATION "Raisecom, Inc." + CONTACT-INFO + " Raise Systems + + Postal: Beijing, + China + + Tel: 86-010-82884499 + + E-mail: support@raisecom.com" + DESCRIPTION + "Configuration of fanMonitor object." +-- ------------------------------------------------------------- +-- modify history +-- ------------------------------------------------------------- + REVISION "201012300000Z" + DESCRIPTION "The initial revision of this MIB." + ::= { raisecomSystem 5} + +-- ------------------------------------------------------------- +-- groups in the raisecomFanMonitor MIB +-- ------------------------------------------------------------- +raisecomFanMonitorNotification OBJECT IDENTIFIER ::= { raisecomFanMonitor 1 } +raisecomFanMonitorMibObjects OBJECT IDENTIFIER ::= { raisecomFanMonitor 2 } + +-- ------------------------------------------------------------- +-- raisecomFanMonitorNotification +-- ------------------------------------------------------------- + raisecomFanSpeedNormal NOTIFICATION-TYPE + OBJECTS { raisecomFanIndex, + raisecomFanSpeedValue + } + STATUS current + DESCRIPTION + "The trap notification occur when fan state translating from abnormal to normal." + ::= { raisecomFanMonitorNotification 1 } + + raisecomFanSpeedAbnormal NOTIFICATION-TYPE + OBJECTS { raisecomFanIndex, + raisecomFanSpeedValue, + raisecomFanSpeedDueValue + } + STATUS current + DESCRIPTION + "The trap notification occur when fan state translatingfrom normal to abnormal." + ::= { raisecomFanMonitorNotification 2 } + + raisecomFanCardUp NOTIFICATION-TYPE + OBJECTS { raisecomFanCardState } + STATUS current + DESCRIPTION + "The trap notification occur when fan card state translating from down to up." + ::= { raisecomFanMonitorNotification 3 } + + raisecomFanCardDown NOTIFICATION-TYPE + OBJECTS { raisecomFanCardState } + STATUS current + DESCRIPTION + "The trap notification occur when fan card state translating from up to down." + ::= { raisecomFanMonitorNotification 4 } +-- ------------------------------------------------------------- +-- raisecomFanMonitorMibObjects +-- ------------------------------------------------------------- +raisecomFanMonitorGlobalGroup OBJECT IDENTIFIER ::= { raisecomFanMonitorMibObjects 1 } + +-- ------------------------------------------------------------- +-- raisecomFanMonitorGlobalGroup +-- ------------------------------------------------------------- + raisecomFanMonitorMode OBJECT-TYPE + SYNTAX INTEGER + { + enforce(1), + auto(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An integer value that specify the current monitor mode. + ENFORCE(1) means that the fan speed need to set manully; + AUTO(2) means that the fan speed will ajusted autoly according + to the temperature" + ::= { raisecomFanMonitorGlobalGroup 1 } + + raisecomFanMonitorSpdLevel OBJECT-TYPE + SYNTAX Unsigned32(1..4) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the speed level of fan in enforce mode." + ::= { raisecomFanMonitorGlobalGroup 2 } + + raisecomFanMonitorNumber OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the number of fan being monitorred." + ::= { raisecomFanMonitorGlobalGroup 3 } + + raisecomFanMonitorLevlNumber OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the total number of fan speed levels." + ::= { raisecomFanMonitorGlobalGroup 4 } + + + raisecomFanCardState OBJECT-TYPE + SYNTAX INTEGER + { + all-down(1), + all-up(2), + card1-up(3), + card2-up(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the current state of fan cards. + all_down(1) means that all fan cards are down; + all_up(2) means that all fan cards are up; + card1_up(3) means that fan card 1 is up, the others are down; + card2_up(4) means that fan card 2 is up, the others are down." + ::= { raisecomFanMonitorGlobalGroup 5 } + + raisecomFanCardSerialNumber OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "specify the identical serial number of current fan card,this + string number will be set when device leaving factory" + ::= { raisecomFanMonitorGlobalGroup 6 } + + raisecomFanMonitorTrapSendEnable OBJECT-TYPE + SYNTAX INTEGER + { + disable(0), + enable (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the status of sending trap" + ::= {raisecomFanMonitorGlobalGroup 7 } + +-- ------------------------------------------------------------- +-- raisecomFanMonitorStateTable +-- ------------------------------------------------------------- + raisecomFanMonitorStateTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomFanMonitorStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Fan monitor state table." + ::= { raisecomFanMonitorMibObjects 2 } + + raisecomFanMonitorStateEntry OBJECT-TYPE + SYNTAX RaisecomFanMonitorStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Fan monitor state entry." + INDEX { raisecomFanIndex } + ::= { raisecomFanMonitorStateTable 1 } + + RaisecomFanMonitorStateEntry ::= SEQUENCE { + raisecomFanIndex Unsigned32, + raisecomFanSpeedValue Unsigned32, + raisecomFanWorkState INTEGER, + raisecomFanSpeedCurrentLevel Unsigned32 + } + + raisecomFanIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specify the sequence number of fan." + ::= { raisecomFanMonitorStateEntry 1 } + + raisecomFanSpeedValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the actural speed of the current fan." + ::= { raisecomFanMonitorStateEntry 2 } + + raisecomFanWorkState OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + abnormal(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the current state of fan + normal(1) means the current fan operate normally; + abnormal(2) means the current fan operate abnormally" + ::= { raisecomFanMonitorStateEntry 3 } + + raisecomFanSpeedCurrentLevel OBJECT-TYPE + SYNTAX Unsigned32(1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the temperature scale border that match the speed levle, + based on this scale border,the current fan speed will ajusted autoly + according to the current temperature" + ::= { raisecomFanMonitorStateEntry 4 } +-- ------------------------------------------------------------- +-- raisecomFanSpeedLevelTable +-- ------------------------------------------------------------- + raisecomFanSpeedLevelTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomFanSpeedLevelEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "fan speed level information table." + ::= { raisecomFanMonitorMibObjects 3 } + + raisecomFanSpeedLevelEntry OBJECT-TYPE + SYNTAX RaisecomFanSpeedLevelEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "fan speed level information entry." + INDEX { raisecomFanSpeedLevelIndex } + ::= { raisecomFanSpeedLevelTable 1 } + + RaisecomFanSpeedLevelEntry ::= SEQUENCE { + raisecomFanSpeedLevelIndex Unsigned32, + raisecomFanSpeedDueValue Unsigned32, + raisecomFanSpeedTemperatureScale Unsigned32 + } + + raisecomFanSpeedLevelIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Specify the fan speed level index." + ::= { raisecomFanSpeedLevelEntry 1 } + + raisecomFanSpeedDueValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specify the speed value that match the fan levle index. + this value can ben get from a new or normal fan ,not an used + fan ,because the used fan may be aged" + ::= { raisecomFanSpeedLevelEntry 2 } + + raisecomFanSpeedTemperatureScale OBJECT-TYPE + SYNTAX Unsigned32(45..75) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specify the temperature scale border that match the speed levle, + based on this scale border,the current fan speed will ajusted autoly + according to the current temperature" + ::= { raisecomFanSpeedLevelEntry 3 } + +END -- cgit v1.2.3