From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/radlan/RADLAN-rndApplications | 1070 ++++++++++++++++++++++++++++++++++++ 1 file changed, 1070 insertions(+) create mode 100644 MIBS/radlan/RADLAN-rndApplications (limited to 'MIBS/radlan/RADLAN-rndApplications') diff --git a/MIBS/radlan/RADLAN-rndApplications b/MIBS/radlan/RADLAN-rndApplications new file mode 100644 index 0000000..b753d90 --- /dev/null +++ b/MIBS/radlan/RADLAN-rndApplications @@ -0,0 +1,1070 @@ +RADLAN-rndApplications DEFINITIONS ::= BEGIN + +-- Title: RADLAN Application Private Extension +-- Version: 7.37.00.00 +-- Date: 17 May 2004 + +IMPORTS + rnd FROM RADLAN-MIB + InterfaceIndexOrZero, InterfaceIndex, ifIndex FROM IF-MIB + DisplayString FROM SNMPv2-TC-v1 + Unsigned32, Counter32, IpAddress, + MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI + RowStatus, TruthValue, + TEXTUAL-CONVENTION FROM SNMPv2-TC; + +rndApplications MODULE-IDENTITY + LAST-UPDATED "200406010000Z" + ORGANIZATION "Radlan Computer Communications Ltd." + CONTACT-INFO + "radlan.com" + DESCRIPTION + "The private MIB module definition for RND applications MIB." + REVISION "200406010000Z" + DESCRIPTION + "Initial version of this MIB." + ::= { rnd 35 } + + +-- Obsolete +-- rsServerDispatcher OBJECT IDENTIFIER ::= { rndApplications 1} + +-- rndMidLevelManagement group contains variables which direct the mid-level +-- management stations how to monitor and manage their domains. + +rndMidLevelManagement OBJECT IDENTIFIER ::= { rndApplications 2} -- NEW Group + +rndAlarmOptions OBJECT IDENTIFIER ::= { rndMidLevelManagement 2} + +rndAlarmEnabling OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates whether alarms should be issued to the high-level + NMS " + ::= { rndAlarmOptions 1 } + +rndAlarmInterval OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates the minimal period of time which must pass after issuing + an alarm before issuing the same alarm again." + ::= { rndAlarmOptions 2 } + +rndMonitoredElementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF RndMonitoredElementEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of monitored elements of the network" + ::= {rndMidLevelManagement 3} + +rndMonitoredElementEntry OBJECT-TYPE + SYNTAX RndMonitoredElementEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The row definition for this table." + INDEX { rndMonitoredElementAddress } + ::= {rndMonitoredElementsTable 1} + +RndMonitoredElementEntry ::= SEQUENCE { + +rndMonitoredElementAddress IpAddress, +rndMonitoredElementCommunity DisplayString(SIZE(1..20)), +rndMonitoredElementLabel DisplayString(SIZE(1..20)), +rndDefaultPollingInterval INTEGER, +rndDefaultLogFile DisplayString, +rndMonitoredElementStatus RowStatus +} +rndMonitoredElementAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP address of the monitored element" + ::= {rndMonitoredElementEntry 1 } + +rndMonitoredElementCommunity OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..20)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The community of the monitored element" + ::= {rndMonitoredElementEntry 2 } + +rndMonitoredElementLabel OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..20)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The label assigned by the network manager to the monitored element" + ::= {rndMonitoredElementEntry 3} + +rndDefaultPollingInterval OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The default period of time between two consecutive pollings of the + monitored element for the value of an object instance. If no other polling + interval is specifically assigned to the monitored object instance, this + one will be used" + ::= {rndMonitoredElementEntry 4} + +rndDefaultLogFile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The default file path of the log-file which will contain the polling + results for the monitored element. If no other file path is specifically + assigned to the monitored object instance, this log-file will be used." + + ::= {rndMonitoredElementEntry 5} + +rndMonitoredElementStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to manage the monitored elements table and indicates + the current monitoring status of an element." + ::= {rndMonitoredElementEntry 6} + +rndMonitoringTable OBJECT-TYPE + SYNTAX SEQUENCE OF RndMonitoringEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of monitored object instances. Each monitored object instance + belongs to a monitored element previously entered in the + rndMonitoredElementsTable. " + ::= {rndMidLevelManagement 4} + +rndMonitoringEntry OBJECT-TYPE + SYNTAX RndMonitoringEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The row definition for this table." + INDEX { rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel } + ::= {rndMonitoringTable 1} + +RndMonitoringEntry ::= SEQUENCE { + +rndMonitoredElement DisplayString(SIZE(1..20)), +rndMonitoredObjectInstanceLabel DisplayString, +rndMonitoredObjectName DisplayString, +rndMonitoredObjectIdentifier OBJECT IDENTIFIER, +rndMonitoredObjectInstance OBJECT IDENTIFIER, +rndMonitoredObjectSyntax INTEGER, +rndMonitoringInterval INTEGER, +rndAlarmMaxTreshold INTEGER, +rndAlarmMinTreshold INTEGER, +rndMonitoringLogfile DisplayString, +rndMonitoringEntryStatus RowStatus, +rndMonitoredIntegerInstance INTEGER +} + +rndMonitoredElement OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A label assigned by the network manager to a monitored element to + which this monitored object instance belongs. This label must have + been previously entered in an instance of rndMonitoredElementLabel" + ::= {rndMonitoringEntry 1} + +rndMonitoredObjectInstanceLabel OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The label assigned by the network manager to the monitored object instance" + ::= {rndMonitoringEntry 2} + +rndMonitoredObjectName OBJECT-TYPE + SYNTAX DisplayString(SIZE(0..20)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The symbolic object type name of the object to which the monitored object + instance belongs (as it appears the MIB module definition). In case of + ambiguity the : format should be used. + An instance of rndMonitoredObjectName need not be assigned any value, if + the corresponding instance of rndMonitoredObjectIdentifier is assigned a + value, since any one of these, together with the object instance + identifier, suffices to unambigously identify the monitored object + instance." + + ::= {rndMonitoringEntry 3} + +rndMonitoredObjectIdentifier OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object identifier of the object to which the monitored object + instance belongs. + An instance of rndMonitoredObjectIdentifier need not be assigned any value, if + the corresponding instance of rndMonitoredObjectName is assigned a value, + since any one of these, together with the object instance identifier, + suffices to unambigously identify the monitored object instance." + + ::= {rndMonitoringEntry 4} + +rndMonitoredObjectInstance OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The instance identifier (key) of the monitored object instance." + ::= {rndMonitoringEntry 5} + +rndMonitoredObjectSyntax OBJECT-TYPE + SYNTAX INTEGER { + integer(1), + octet-string(2), + ip-address(3), + object-identifier(4) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The syntax of the monitored object instance (i.e., the syntax of the object + type of the object to which the monitored instance belongs). + Need not be assigned any value if the corresponding instance of + rndMonitoredObjectName has been assigned a value" + ::= {rndMonitoringEntry 6} + +rndMonitoringInterval OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The period of time between two consecutive retrievals of the monitored + object instance's value." + ::= {rndMonitoringEntry 7} + + +rndAlarmMaxTreshold OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The value of the monitored object instance, the exceeding of which + will cause the generation of an alarm to the high-level management + station." + ::= {rndMonitoringEntry 8} + +rndAlarmMinTreshold OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If the value of the monitored object instance falls below the value + assigned to rndAlarmMinTreshold, an alarm to the high-level management + station will be issued." + ::= {rndMonitoringEntry 9} + + +rndMonitoringLogfile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The entire path of the file in which the results of the monitoring + of this object instance should be recorded." + ::= {rndMonitoringEntry 10} + +rndMonitoringEntryStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to manage the monitored object instances table and + indicates the current monitoring status of an object instance." + ::= {rndMonitoringEntry 11} + +rndMonitoredIntegerInstance OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= {rndMonitoringEntry 12} + +rndMibFilesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RndMibFileEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of monitored object instances. Each monitored object instance + belongs to a monitored element previously entered in the + rndMonitoredElementsTable. " + ::= {rndMidLevelManagement 5} + +rndMibFileEntry OBJECT-TYPE + SYNTAX RndMibFileEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The row definition for this table." + INDEX { rndMibFileIndex } + ::= {rndMibFilesTable 1} + +RndMibFileEntry ::= SEQUENCE { + +rndMibFileIndex INTEGER, +rndMibFilePath DisplayString, +rndMibFileRefresh INTEGER, +rndMibFileEntryStatus RowStatus +} +rndMibFileIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the MIB file in the list MIB files supported by the + Mid-Level management station. The order of the MIB files in this + list must reflect the the IMPORT relation between the MIBS contained + in the MIB files, i.e., if MIB A IMPORTS FROM MIB B, the file containing + MIB A must have a lesser index in this table than the file containing + MIB B." + ::= {rndMibFileEntry 1} + + +rndMibFilePath OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The path of the MIB file in the MIB file server." + ::= {rndMibFileEntry 2} + +rndMibFileRefresh OBJECT-TYPE + SYNTAX INTEGER { + no(1), + yes(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates if the file should be fetched after setting this entry from the + MIB file server." + ::= {rndMibFileEntry 3} + +rndMibFileEntryStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to manage the MIB files table." + ::= {rndMibFileEntry 4} + +rndHardwareConfiguration OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates whether the current SET SNMP PDU contains hardware + configuration (i.e., normally read-only variables). SET of such + variables in the Mid-level management station will be allowed only + if this variable is included in the SNMP PDU and its value is true. + Its value as returned in a GET SNMP PDU will always be false." + ::= {rndMidLevelManagement 6} + +rndEraseSimulatedConfiguration OBJECT-TYPE + SYNTAX INTEGER { + eraseSimulatedConfiguration(1), + simulatedConfigurationPresent(2), + simulatedConfigurationErased(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "eraseSimulatedConfiguration instructs the MLNMS to erase all the + simulated configuration from its configuration data-base (CDB). This + the only accepted value for SNMP SET statements and will never be + returned in SNMP GET statements. + simulatedConfigurationPresent indicates that the MLNMS currently has + a simulated configuration. + simulatedConfigurationErased indicates that the MLNMS currently has + no simulated configuration." + ::= {rndMidLevelManagement 7} + +rndDeleteValuesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RndDeleteValuesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table indicates which MIB variables are row status fields which + control the status of the entry to which they belong. This table also + indicates which (integer!) value of these MIB variables will cause, if + present in a SNMP SET PDU, the deletion of the conceptual row instance + to which the SET MIB variable instance belongs." + ::= {rndMidLevelManagement 8} + +rndDeleteValuesEntry OBJECT-TYPE + SYNTAX RndDeleteValuesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The row definition for the rndDeleteValuesTable table." + INDEX { IMPLIED rndRowStatusVariableName } + ::= {rndDeleteValuesTable 1} + +RndDeleteValuesEntry ::= SEQUENCE { + +rndRowStatusVariableName DisplayString, +rndRowStatusObjectId OBJECT IDENTIFIER, +rndRowDeleteValue INTEGER, +rndDeleteValueEntryStatus RowStatus +} + +rndRowStatusVariableName OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..80)) +-- MAX-ACCESS read-only + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The name of the row status field. This name may not necessarily be any + name which is present in the MIBs loaded into the MLNMS station." + + ::= {rndDeleteValuesEntry 1} + +rndRowStatusObjectId OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object id of the row status field. If the rndRowStatusVariableName is + a name present in the MIBs loaded into the MLNMS, this MIB + variable is not required, but if given, it must match the object id known + to the MLNMS. + The variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId + must be a read-write MIB variable of type INTEGER which belongs to an + entry (i.e, is a child of a MIB variable of type SEQUENCE)." + + ::= {rndDeleteValuesEntry 2} + +rndRowDeleteValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The value of the variable identified by rndRowStatusVariableName and/or + rndRowStatusObjectId, which, if present in a SNMP SET PDU, will cause + the deletion of the conceptual row instance which the SET MIB variable + instance belongs." + ::= {rndDeleteValuesEntry 3} + +rndDeleteValueEntryStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to delete an entry from this table." + ::= {rndDeleteValuesEntry 4} + +snmpTesting OBJECT IDENTIFIER ::= { rndMidLevelManagement 9} + +rndSimulatedVariablesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RndSimulatedVariablesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table indicates which MIB variables are simulated." + ::= {snmpTesting 1} + +rndSimulatedVariablesEntry OBJECT-TYPE + SYNTAX RndSimulatedVariablesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The row definition for the rndSimulatedVariablesTable table." + INDEX { rndSimulatedVariableEntryIndex } + ::= {rndSimulatedVariablesTable 1} + +RndSimulatedVariablesEntry ::= SEQUENCE { + +rndSimulatedVariableEntryIndex INTEGER, +rndSimulatedVariableObjectId OBJECT IDENTIFIER, +rndNotSupportedField INTEGER, +rndSimulatedVariableEntryStatus RowStatus +} + +rndSimulatedVariableEntryIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index entry." + + ::= {rndSimulatedVariablesEntry 1} + +rndSimulatedVariableObjectId OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The object id of the simulated variable. If the simulated variable belongs + to a table entry, the entire entry is henceforth supported." + + ::= {rndSimulatedVariablesEntry 2} + +rndNotSupportedField OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Variable for not supported simulation." + ::= {rndSimulatedVariablesEntry 3} + +rndSimulatedVariableEntryStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "It is used to delete an entry from this table." + ::= {rndSimulatedVariablesEntry 4} + +rndSnmpTestPassword OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the user supplying the correct code to use the + SNMP test feature." + ::= {snmpTesting 2} + +rndSnmpTests OBJECT-TYPE + SYNTAX INTEGER { + noSimulation(1), + simulateSetFailure(2), + simulateAppGet(3), + simulateAppGetNext(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the authorized user to test various SNMP features." + ::= {snmpTesting 3} + +rndSimulateUndo OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the authorized user to test the SNMP UNDO feature." + ::= {snmpTesting 4} + +rlSnmpServTestRequest OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the authorized user to test the SNMP SERV package." + ::= {snmpTesting 5} + +rlSnmpServTestResponse OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable enables the authorized user to retrieve the results of + a the SNMP SERV package test." + ::= {snmpTesting 6} + +rlSnmpServCreateTestPool OBJECT-TYPE + SYNTAX INTEGER { create(1), no-create(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the authorized user to indicate that after its reset + the device should create a buffer pool for SNMPServ process PDU + testing." + ::= {snmpTesting 7} + +rlSnmpServITCbindClients OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable enables the authorized user to to indicate that after + its reset the device should create ITC clients for SnmpServ data + requests clients. + The semantics of this variable is as follows: + subidentifier 2*n indicates whether the client n is synchronous(1) or + asynchronous(2) + subidentifier 2*n+1 indicates the number of simulatneous requests + expected by client n." + ::= {snmpTesting 8} + +rlSnmpTestSimulatedVariables OBJECT IDENTIFIER ::= {snmpTesting 9} + +rlTstBasicRateTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlTstBasicRateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table for testing SNMP agent." + ::= { snmpTesting 10 } + +rlTstBasicRateEntry OBJECT-TYPE + SYNTAX RlTstBasicRateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the rlTstBasicRateTable." + INDEX { ifIndex } + ::= { rlTstBasicRateTable 1 } + +RlTstBasicRateEntry ::= SEQUENCE { + rlTstBasicRateIfType INTEGER, + rlTstBasicRateLineTopology INTEGER, + rlTstBasicRateIfMode INTEGER, + rlTstBasicRateSignalMode INTEGER + } + +rlTstBasicRateIfType OBJECT-TYPE + SYNTAX INTEGER { + isdns(75), + isdnu(76) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= { rlTstBasicRateEntry 1 } + +rlTstBasicRateLineTopology OBJECT-TYPE + SYNTAX INTEGER { + pointToPoint(1), + pointToMultipoint(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= { rlTstBasicRateEntry 2 } + +rlTstBasicRateIfMode OBJECT-TYPE + SYNTAX INTEGER { + te(1), + nt(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= { rlTstBasicRateEntry 3 } + +rlTstBasicRateSignalMode OBJECT-TYPE + SYNTAX INTEGER { + active(1), + inactive(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "" + ::= { rlTstBasicRateEntry 4 } + +rlMibTree OBJECT IDENTIFIER ::= {rndMidLevelManagement 10 } + +rlMibTreeTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlMibTreeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This reflects the MIB tree of the device." + ::= {rlMibTree 1 } + + +rlMibTreeEntry OBJECT-TYPE + SYNTAX RlMibTreeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " Each row shows a tree relationsship in the MIB." + INDEX { rlMibTreeFather, rlMibTreeSonIndex } + ::= {rlMibTreeTable 1 } + + RlMibTreeEntry ::= SEQUENCE { + + rlMibTreeFather DisplayString, + rlMibTreeSonIndex INTEGER, + rlMibTreeSon DisplayString, + rlMibTreeSonObjectId OBJECT IDENTIFIER, + rlMibTreeGrandFather DisplayString +} + + + rlMibTreeFather OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The father in a tree relation ship." + ::= {rlMibTreeEntry 1 } + + rlMibTreeSonIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " Running index for this table." + ::= {rlMibTreeEntry 2 } + + rlMibTreeSon OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The son in a tree relation ship." + ::= {rlMibTreeEntry 3 } + + rlMibTreeSonObjectId OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The object identifier of the son in a tree relation ship." + ::= {rlMibTreeEntry 4} + + rlMibTreeGrandFather OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The grand father (i.e father's father) in a tree relation ship." + ::= {rlMibTreeEntry 5 } + + +-- Obsolete +-- rsIpZeroHopRouting OBJECT IDENTIFIER ::= { rndApplications 3} + + +rsPingMIB OBJECT IDENTIFIER ::= { rndApplications 4} -- NEW Group +rsPingTable OBJECT-TYPE + SYNTAX SEQUENCE OF RsPingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of ping request entries." + ::= { rsPingMIB 1 } + +rsPingEntry OBJECT-TYPE + SYNTAX RsPingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A ping request entry. + + A management station wishing to create an entry should + first generate a pseudo-random serial number to be used + as the index to this sparse table. It must also create in the same + PDU the associated instance of the address object. It should also + modify in the same PDU the default values for the other configuration + objects if the defaults are not appropriate. + + Once the sequence completes, the management station should + retrieve the values of the status objects of interest, and + should then delete the entry. In order to prevent old + entries from clogging the table, entries will be aged out, + but an entry will never be deleted within 5 minutes of + completing." + INDEX { rsPingAddress } + ::= { rsPingTable 1 } + +RsPingEntry ::= SEQUENCE { + rsPingAddress IpAddress, + rsPingPacketCount INTEGER, + rsPingPacketSize INTEGER, + rsPingPacketTimeout INTEGER, + rsPingDelay INTEGER, + rsPingTrapOnCompletion TruthValue, + rsPingSentPackets Counter32, + rsPingReceivedPackets Counter32, + rsPingMinReturnTime INTEGER, + rsPingAvgReturnTime INTEGER, + rsPingMaxReturnTime INTEGER, + rsPingCompletionStatus INTEGER, + rsPingTimeStamp DisplayString, + rsPingEntryStatus RowStatus + } + +rsPingAddress OBJECT-TYPE + SYNTAX IpAddress +-- Rsyntax OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The address of the device to be pinged. + Once an instance of this object is created, its + value can not be changed." + ::= { rsPingEntry 1 } + +rsPingPacketCount OBJECT-TYPE + SYNTAX INTEGER(1..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the number of ping packets to send to the target + in this sequence." +-- DEFVAL { 5 } + ::= { rsPingEntry 2 } + + rsPingPacketSize OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the size of ping packets to send to the target + in this sequence. The lower and upper boundaries of this + object are implementation dependent." +-- DEFVAL { 100 } + ::= { rsPingEntry 3 } + +rsPingPacketTimeout OBJECT-TYPE + SYNTAX INTEGER(0..3600000) +-- Units +-- milliseconds + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the amount of time to wait for a response to a + transmitted packet before declaring the packet 'dropped.'" +-- DEFVAL { 2000 } + ::= { rsPingEntry 4 } + +rsPingDelay OBJECT-TYPE + SYNTAX INTEGER(0..3600000) +-- Units +-- milliseconds + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the minimum amount of time to wait before sending + the next packet in a sequence after receiving a response. + The actual delay may be greater due to internal task scheduling." +-- DEFVAL { 0 } + ::= { rsPingEntry 5 } + +rsPingTrapOnCompletion OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether or not a rsPingCompletion trap should + be issued on completion of the sequence of pings. If such a + trap is desired, the NMS should ensure that the community table + contains an instance specified by the NMSs IP address with + rndCommunityTrapsEnable = trapsEnable." +-- DEFVAL { false } + ::= { rsPingEntry 6 } + +rsPingSentPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of ping packets that have been sent to the target + in this sequence." + ::= { rsPingEntry 7 } + +rsPingReceivedPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of ping packets that have been received from the + target in this sequence." + ::= { rsPingEntry 8 } + +rsPingMinReturnTime OBJECT-TYPE + SYNTAX INTEGER +-- Units +-- milliseconds + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum round trip time of all the packets that have + been sent in this sequence. The value returned to a GET request + is meaningless if no ping response in a sequence has been received + yet." + ::= { rsPingEntry 9 } + +rsPingAvgReturnTime OBJECT-TYPE + SYNTAX INTEGER +-- Units +-- milliseconds + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average round trip time of all the packets that have + been sent in this sequence.The value returned to a GET request + is meaningless if no ping response in a sequence has been received + yet." + ::= { rsPingEntry 10 } + +rsPingMaxReturnTime OBJECT-TYPE + SYNTAX INTEGER +-- Units +-- milliseconds + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum round trip time of all the packets that have + been sent in this sequence.The value returned to a GET request + is meaningless if no ping response in a sequence has been received + yet." + ::= { rsPingEntry 11 } + +rsPingCompletionStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + timeout(2), + net-unreachable(3), + host-unreachable(4), + protocol-unreachable(5), + time-to-live-exceeded(6), + reassembly-time-exceeded(7), + unable-to-send(8), + bad-reply-data(9), + incomplete(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If all the echo request packets in this sequence have been + responded by valid echo responses, this object is set to ok. + Otherwise this status indicates the problem. bad-reply-data indicates + that the reply data is not equal to the response data." + ::= { rsPingEntry 12 } + +rsPingTimeStamp OBJECT-TYPE + SYNTAX DisplayString(SIZE(19)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time-stamp indicating the time and date of creation or last + update of this request. The format of the time-stamp is + dd/mm/yyyy hh:mm:ss" + ::= { rsPingEntry 13 } + + +rsPingEntryStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The status of this table entry." + ::= { rsPingEntry 14 } + +rsPowerSupplyRedundacy OBJECT IDENTIFIER ::= { rndApplications 5} -- NEW Group +rsPowerSupplyRedundacyTable OBJECT-TYPE + SYNTAX SEQUENCE OF RsPowerSupplyRedundacyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The power supply redundancy table." + ::= { rsPowerSupplyRedundacy 1 } + +rsPowerSupplyRedundacyEntry OBJECT-TYPE + SYNTAX RsPowerSupplyRedundacyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The status of power supply redundancy for this table." + INDEX { rsPowerSupplyRedundacyReNumber} + ::= { rsPowerSupplyRedundacyTable 1} + +RsPowerSupplyRedundacyEntry ::= SEQUENCE { + rsPowerSupplyRedundacyReNumber INTEGER, + rsPowerSupplyRedundacyStatus INTEGER + } + +rsPowerSupplyRedundacyReNumber OBJECT-TYPE + SYNTAX INTEGER (1..31) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This number identifies the module backed up + by power supply redundancy in the stack." + ::= { rsPowerSupplyRedundacyEntry 1} + +rsPowerSupplyRedundacyStatus OBJECT-TYPE + SYNTAX INTEGER{ + notExist(1), + existButNotWorking(2), + bothWorking(3), + internalOnlyWorking(4), + externalOnlyWorking(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of a power supply redundancy of the entry." + ::= { rsPowerSupplyRedundacyEntry 2} + +rsNvram OBJECT IDENTIFIER ::= { rndApplications 6 } +rsEraseNvramAfterReset OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The name of NVRAM application that will be erased + after reset or ALL if all NVRAM should be erased." + ::= { rsNvram 1 } + +rsNvramApplTable OBJECT-TYPE + SYNTAX SEQUENCE OF RsNvramApplEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The NVRAM application table." + ::= { rsNvram 2 } + +rsNvramApplEntry OBJECT-TYPE + SYNTAX RsNvramApplEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The status of NVRAM application table." + INDEX { rsNvramApplIndex} + ::= { rsNvramApplTable 1} + +RsNvramApplEntry ::= SEQUENCE { + rsNvramApplIndex INTEGER, + rsNvramApplName DisplayString + } + +rsNvramApplIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of NVRAM application table." + ::= { rsNvramApplEntry 1} + +rsNvramApplName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of application used NVRAM." + ::= { rsNvramApplEntry 2} + +END + -- cgit v1.2.3