From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/pfsense/BEGEMOT-ATM | 301 +++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 301 insertions(+) create mode 100644 MIBS/pfsense/BEGEMOT-ATM (limited to 'MIBS/pfsense/BEGEMOT-ATM') diff --git a/MIBS/pfsense/BEGEMOT-ATM b/MIBS/pfsense/BEGEMOT-ATM new file mode 100644 index 0000000..f6cca96 --- /dev/null +++ b/MIBS/pfsense/BEGEMOT-ATM @@ -0,0 +1,301 @@ +-- +-- Copyright (c) 2001-2002 +-- Fraunhofer Institute for Open Communication Systems (FhG Fokus). +-- All rights reserved. +-- Copyright (c) 2004 +-- Hartmut Brandt. +-- All rights reserved. +-- +-- Author: Hartmut Brandt +-- +-- Redistribution and use in source and binary forms, with or without +-- modification, are permitted provided that the following conditions +-- are met: +-- 1. Redistributions of source code must retain the above copyright +-- notice, this list of conditions and the following disclaimer. +-- 2. Redistributions in binary form must reproduce the above copyright +-- notice, this list of conditions and the following disclaimer in the +-- documentation and/or other materials provided with the distribution. +-- +-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND +-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE +-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE +-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE +-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL +-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS +-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) +-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT +-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY +-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF +-- SUCH DAMAGE. +-- +-- $Begemot: libunimsg/snmp_atm/BEGEMOT-ATM.txt,v 1.2 2004/08/06 14:50:26 brandt Exp $ +-- +-- Private Begemot MIB for ATM interfaces. +-- +BEGEMOT-ATM-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, TimeTicks + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, DisplayString + FROM SNMPv2-TC + ifIndex + FROM IF-MIB + begemot + FROM BEGEMOT-MIB; + +begemotAtm MODULE-IDENTITY + LAST-UPDATED "200407190000Z" + ORGANIZATION "German Aerospace Centre" + CONTACT-INFO + " Hartmut Brandt + + Postal: German Aerospace Centre (DLR) + Institute of Communications and Navigation + 82234 Wessling + Germany + + Fax: +49 8153 28 2844 + + E-mail: harti@freebsd.org" + DESCRIPTION + "The Begemot MIB for ATM interfaces." + + ::= { begemot 101 } + +begemotAtmObjects OBJECT IDENTIFIER ::= { begemotAtm 1 } + +-- -------------------------------------------------------------------------- + +AtmESI ::= TEXTUAL-CONVENTION + DISPLAY-HINT "1x:" + STATUS current + DESCRIPTION + "An ATM End System Identifier. This is basically the same as + an Ethernet Address and is assigned using the same rules." + SYNTAX OCTET STRING (SIZE(6)) + +-- -------------------------------------------------------------------------- + +-- +-- Interfaces table +-- +begemotAtmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF BegemotAtmIfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains an entry for each hardware ATM + interface. The table is indexed by the interface index." + ::= { begemotAtmObjects 1 } + +begemotAtmIfEntry OBJECT-TYPE + SYNTAX BegemotAtmIfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a table entry describing one ATM hardware interface." + INDEX { ifIndex } + ::= { begemotAtmIfTable 1 } + +BegemotAtmIfEntry ::= SEQUENCE { + begemotAtmIfName DisplayString, + begemotAtmIfPcr Unsigned32, + begemotAtmIfMedia INTEGER, + begemotAtmIfVpiBits Unsigned32, + begemotAtmIfVciBits Unsigned32, + begemotAtmIfMaxVpcs Unsigned32, + begemotAtmIfMaxVccs Unsigned32, + begemotAtmIfEsi AtmESI, + begemotAtmIfCarrierStatus INTEGER, + begemotAtmIfMode INTEGER +} + +begemotAtmIfName OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of the ATM interface." + ::= { begemotAtmIfEntry 1 } + +begemotAtmIfPcr OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The line cell rate of the interface." + ::= { begemotAtmIfEntry 2 } + +begemotAtmIfMedia OBJECT-TYPE + SYNTAX INTEGER { + other(1), + unknown(3), + utp25(4), + taxi100(5), + taxi140(6), + mm155(7), + sm155(8), + utp155(9), + mm622(10), + sm622(11), + virtual(12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The physical medium." + ::= { begemotAtmIfEntry 3 } + +begemotAtmIfVpiBits OBJECT-TYPE + SYNTAX Unsigned32 (0..12) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of VPI bits that are used by the device." + ::= { begemotAtmIfEntry 4 } + +begemotAtmIfVciBits OBJECT-TYPE + SYNTAX Unsigned32 (0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of VCI bits that are used by the device." + ::= { begemotAtmIfEntry 5 } + +begemotAtmIfMaxVpcs OBJECT-TYPE + SYNTAX Unsigned32 (0..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of VPC supported on this device. This may not + be larger than 2^begemotAtmIfVpiBits." + ::= { begemotAtmIfEntry 6 } + +begemotAtmIfMaxVccs OBJECT-TYPE + SYNTAX Unsigned32 (0..16777216) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of VCC supported on this device. This may not + be larger than 2^(begemotAtmIfVpiBits + begemotAtmVciBits)." + ::= { begemotAtmIfEntry 7 } + +begemotAtmIfEsi OBJECT-TYPE + SYNTAX AtmESI + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The default End System Identifier as reported by the hardware. + If the hardware has no ESI all six bytes are reported as 0." + ::= { begemotAtmIfEntry 8 } + +begemotAtmIfCarrierStatus OBJECT-TYPE + SYNTAX INTEGER { carrierOn(1), carrierOff(2), unknown(3), none(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the carrier. For interfaces which don't have the + notion of a carriere none is reported." + ::= { begemotAtmIfEntry 9 } + +begemotAtmIfMode OBJECT-TYPE + SYNTAX INTEGER { sonet(1), sdh(2), unknown(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The mode of the SUNI interface. For interfaces without SUNI + unknown is reported in which case the variable is read-only. + Some types of interfaces may not be able to change this value." + ::= { begemotAtmIfEntry 10 } + +begemotAtmIfTableLastChange OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime the last time that an entry in + begemotIfTable was created or destroyed. If the table is + unchanged since the last coldStart this value is zero." + ::= { begemotAtmObjects 2 } + +-- +-- Interface hardware table +-- +begemotAtmHWTable OBJECT-TYPE + SYNTAX SEQUENCE OF BegemotAtmHWEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table augments the begemotAtmIfTable and contains an entry + for each hardware ATM interface. The entries describe the + ATM hardware interface." + ::= { begemotAtmObjects 3 } + +begemotAtmHWEntry OBJECT-TYPE + SYNTAX BegemotAtmHWEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a table entry describing one ATM hardware interface." + AUGMENTS { begemotAtmIfEntry } + ::= { begemotAtmHWTable 1 } + +BegemotAtmHWEntry ::= SEQUENCE { + begemotAtmHWVendor DisplayString, + begemotAtmHWDevice DisplayString, + begemotAtmHWSerial Unsigned32, + begemotAtmHWVersion Unsigned32, + begemotAtmHWSoftVersion Unsigned32 +} + +begemotAtmHWVendor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A short string naming the vendor of the interface card." + ::= { begemotAtmHWEntry 1 } + +begemotAtmHWDevice OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A short string naming the brand of the interface card." + ::= { begemotAtmHWEntry 2 } + +begemotAtmHWSerial OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of the interface card or 0 if it doesn't + report a serial number." + ::= { begemotAtmHWEntry 3 } + +begemotAtmHWVersion OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hardware version of the interface card or 0 if it doesn't + report a hardware version number." + ::= { begemotAtmHWEntry 4 } + +begemotAtmHWSoftVersion OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The firmware version of the interface card or 0 if it doesn't + report a firmware version number." + ::= { begemotAtmHWEntry 5 } + +-- -------------------------------------------------------------------- + +-- System specific parts +begemotAtmSysGroup OBJECT IDENTIFIER ::= { begemotAtmObjects 4 } + +END -- cgit v1.2.3