From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB | 188 +++++++++++++++++++++++++++++++++++ 1 file changed, 188 insertions(+) create mode 100644 MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB (limited to 'MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB') diff --git a/MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB b/MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB new file mode 100644 index 0000000..e440122 --- /dev/null +++ b/MIBS/mimosa/MIMOSA-NETWORKS-BASE-MIB @@ -0,0 +1,188 @@ +MIMOSA-NETWORKS-BASE-MIB DEFINITIONS ::= BEGIN + +-- Copyright (C) 2015, Mimosa Networks, Inc. All Rights Reserved. +-- +-- Mimosa Networks MIB +-- Revision: 1.00 +-- Date: June 03, 2015 +-- +-- Mimosa Networks, Inc. +-- 300 Orchard City Dr. +-- Campbell, CA 95008 +-- support@mimosa.co +-- +-- This MIB defines the base MIB specification for Mimosa Network's +-- products. +-- +-- Mimosa reserves the right to make changes to this MIB specification as +-- well as other information related to this specification without prior +-- notice. The user of this specification should consult Mimosa Networks, +-- to determine if any such changes have been made. +-- +-- Current MIBs are available from Mimosa Networks at the following URLs: +-- +-- http://help.mimosa.co +-- +-- In no event shall Mimosa Networks, Inc. be liable for any indirect, +-- consequential, special or incidental damages whatsoever (including +-- but not limited to lost profits or lost revenue) arising out of or +-- related to this specification or the information contained in it. +-- This non-liability extends to even if Mimosa Networks Inc. has been +-- advised of, known, or should have known, the potential for such damages. + +-- Mimosa Networks, Inc. hereby grants end-users, and other parties a +-- a non-exclusive license to use this MIB specification in order to +-- manage products of Mimosa Networks, Inc. + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Integer32, + NOTIFICATION-TYPE FROM SNMPv2-SMI + OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF + enterprises FROM RFC1155-SMI + ifIndex FROM IF-MIB; + + +-- EXPORTS mimosa... +mimosa MODULE-IDENTITY + LAST-UPDATED "201506030000Z" + ORGANIZATION "Mimosa Networks + www.mimosa.co" + CONTACT-INFO + "postal: + Mimosa Networks, Inc. + 300 Orchard City Dr. + Campbell, CA 95008 + email: support@mimosa.co" + DESCRIPTION + "Mimosa device MIB definitions" + REVISION "201506030000Z" + DESCRIPTION + "First draft" + ::= { enterprises 43356 } + +--mimosa OBJECT IDENTIFIER ::= { enterprises 43356 } + +mimosaProduct OBJECT IDENTIFIER ::= { mimosa 1 } +mimosaMgmt OBJECT IDENTIFIER ::= { mimosa 2 } + + +mimosaHardware OBJECT IDENTIFIER ::= { mimosaProduct 1 } +mimosaSoftware OBJECT IDENTIFIER ::= { mimosaProduct 2 } + +mimosaB5 OBJECT IDENTIFIER ::= { mimosaHardware 1 } +mimosaB5Lite OBJECT IDENTIFIER ::= { mimosaHardware 2 } +mimosaA5 OBJECT IDENTIFIER ::= { mimosaHardware 3 } +mimosaC5 OBJECT IDENTIFIER ::= { mimosaHardware 4 } + +mimosaTrap OBJECT IDENTIFIER ::= { mimosaMgmt 0 } +mimosaMib OBJECT IDENTIFIER ::= { mimosaMgmt 1 } +mimosaMIBGroups OBJECT IDENTIFIER ::= { mimosaMgmt 3 } +mimosaConformanceGroup OBJECT IDENTIFIER ::= { mimosaMgmt 4 } + +mimosaTrapMib OBJECT IDENTIFIER ::= { mimosaMib 1 } +mimosaWireless OBJECT IDENTIFIER ::= { mimosaMib 2 } + + +-- ********************************************************************** +-- *** Mimosa General MIB variables are specified below. *** +-- *** These varbinds are common to all Mimosa products. *** +-- ********************************************************************** + +mimosaTrapMIBGroup OBJECT-GROUP + OBJECTS { mimosaTrapMessage, + mimosaOldSpeed, + mimosaNewSpeed + } + STATUS current + DESCRIPTION + "A collection of objects providing basic Trap function." + ::= { mimosaMIBGroups 1 } + + +mimosaTrapMessage OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "General Octet String object to contain message sent with traps." + ::= { mimosaTrapMib 1 } + +mimosaOldSpeed OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The speed of the Ethernet link before the change within Ethernet + Speed Change Notifications." + ::= { mimosaTrapMib 2 } + +mimosaNewSpeed OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The speed of the Ethernet link after the change within Ethernet + Speed Change Notifications." + ::= { mimosaTrapMib 3 } + + +-- ********************************************************************** +-- *** Mimosa Generic Traps are specified below. *** +-- *** These traps are common to all Mimosa products. *** +-- ********************************************************************** + +mimosaGenericNotificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { mimosaCriticalFault, mimosaTempWarning, + mimosaTempNormal, mimosaEthernetSpeedChange } + STATUS current + DESCRIPTION + "The basic Trap notifications for all Mimosa products." + ::= { mimosaMIBGroups 2 } + + +mimosaCriticalFault NOTIFICATION-TYPE + OBJECTS { mimosaTrapMessage } + STATUS current + DESCRIPTION + "The mimosaCriticalFault notification is sent when the log manager + in the Mimosa product determines that a fault with a critical + severity has been detected. The mimosaCriticalFaultLog contains + the description of the general error." + ::= {mimosaTrap 1 } + +mimosaTempWarning NOTIFICATION-TYPE + OBJECTS { mimosaTrapMessage } + STATUS current + DESCRIPTION + "The mimosaTempWarning notification is sent when the log manager in + the Mimosa product receives an indication that the temperature is + outside the safe range." + ::= {mimosaTrap 2 } + +mimosaTempNormal NOTIFICATION-TYPE + OBJECTS { mimosaTrapMessage } + STATUS current + DESCRIPTION + "The mimosaTempNormal notification is sent when the log manager in the + Mimosa product receives an indication that the temperature is with + in the safe range." + ::= {mimosaTrap 3 } + +mimosaEthernetSpeedChange NOTIFICATION-TYPE + OBJECTS { ifIndex, mimosaOldSpeed, mimosaNewSpeed } + STATUS current + DESCRIPTION + "The mimosaEthernetSpeedChange notification is sent when the log manager + in the Mimosa product determines that a speed change on the Ethernet + port was detected. The mimosaOldSpeed and mimosaNewSpeed indicates the + speed in bits per second of the change. ifIndex is used per the ifTable + in the IF-MIB." + ::= {mimosaTrap 4 } + +-- Note the following publicly defined traps are also used for Mimosa Product +-- Notifications: +-- +-- From SNMPv2-MIB: coldStart, warmStart, linkUp, LinkDown and +-- authenticationFailure +END + -- cgit v1.2.3