From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/deltanet/Deltanet-MIB | 19 + MIBS/deltanet/LAMBDATRAIL-MIB | 1147 +++++++++++++++++++++++++++++++++++++++ MIBS/deltanet/Lambdatrail2s-MIB | 1143 ++++++++++++++++++++++++++++++++++++++ 3 files changed, 2309 insertions(+) create mode 100644 MIBS/deltanet/Deltanet-MIB create mode 100644 MIBS/deltanet/LAMBDATRAIL-MIB create mode 100644 MIBS/deltanet/Lambdatrail2s-MIB (limited to 'MIBS/deltanet') diff --git a/MIBS/deltanet/Deltanet-MIB b/MIBS/deltanet/Deltanet-MIB new file mode 100644 index 0000000..8ff36c2 --- /dev/null +++ b/MIBS/deltanet/Deltanet-MIB @@ -0,0 +1,19 @@ +Deltanet-MIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises, MODULE-IDENTITY + FROM SNMPv2-SMI; + +deltanet MODULE-IDENTITY + LAST-UPDATED "201411060000Z" + ORGANIZATION "DeltaNet AG Switzerland" + CONTACT-INFO "http://www.deltanet.ch" + DESCRIPTION "MIB module for defining Deltanet headers." + REVISION "201411060000Z" + DESCRIPTION "Initial Version" + ::= { enterprises 35616 } + +productType OBJECT IDENTIFIER ::= { deltanet 2 } +xwdm OBJECT IDENTIFIER ::= { productType 1 } + +END diff --git a/MIBS/deltanet/LAMBDATRAIL-MIB b/MIBS/deltanet/LAMBDATRAIL-MIB new file mode 100644 index 0000000..e3606fb --- /dev/null +++ b/MIBS/deltanet/LAMBDATRAIL-MIB @@ -0,0 +1,1147 @@ +LAMBDATRAIL-MIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises, private, NetworkAddress, + IpAddress, Counter, Gauge, TimeTicks + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212; + + DisplayString ::= + OCTET STRING + -- This data type is used to model textual information taken + -- from the NVT ASCII character set. By convention, objects + -- with this syntax are declared as having + + + + -- + -- SIZE (0..255) + + PhysAddress ::= + OCTET STRING + -- This data type is used to model media addresses. For many + -- types of media, this will be in a binary representation. + -- For example, an ethernet address would be represented as + -- a string of 6 octets. + +-- revision date: Apr. 09, 2010 + +deltanet OBJECT IDENTIFIER ::= { enterprises 35616 } + +-- Deltanet AG Specific Objects + +snmpAgent OBJECT IDENTIFIER ::= { deltanet 1 } +productType OBJECT IDENTIFIER ::= { deltanet 2 } + +cwdm OBJECT IDENTIFIER ::= { productType 1 } + +lambdatrail OBJECT IDENTIFIER ::= { cwdm 1 } + +-- Software group + +agentSw OBJECT IDENTIFIER ::= { snmpAgent 1 } + +agentSoftwareMajorVer OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The major software version number of the agent + run time image." + ::= { agentSw 1 } + +agentSoftwareMinorVer OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The minor software version number of the agent + run time image." + ::= { agentSw 2 } + +agentOutBandBaudRate OBJECT-TYPE + SYNTAX INTEGER { + b9600(9600), + b19200(19200), + b38400(38400), + b57600(57600), + b115200(115200) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The baud rate setting for the out-of-band port." + ::= { snmpAgent 2 } + +agentConsoleIdleTimeouts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "timeouts is 0 or 60-86400, unit is second, 0: never idle, + default is 600" + ::= { snmpAgent 3 } + +agentPrompt OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 4 } + +agentBootMethod OBJECT-TYPE + SYNTAX INTEGER { + manual(1), + dhcp(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 5 } + +agentIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The agent's administrative IP address. The + current operational IP address can be obtained from + the ipAdEntAddr in the ipAddrTable. This parameter + will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { snmpAgent 6 } + +agentIpNetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The agent's administrative IP subnet mask. The + current operational IP subnet mask can be obtained from + the ipAdEntMask in the ipAddrTable. This parameter + will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { snmpAgent 7 } + +agentDefaultGateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The agent's administrative default gateway IP address. + The current operational IP default gateway IP address + can be obtained from the ipRouteDest in the ipRouteTable. + This parameter will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { snmpAgent 8 } + +agentPrimaryDnsServer OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 9 } + +agentSecondaryDnsServer OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 10 } + +agentSnmpServer OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 11 } + +agentHttpServer OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 12 } + +agentTelnet OBJECT IDENTIFIER ::= { snmpAgent 13 } + +agentTelnetServer OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTelnet 1 } + +agentTelnetIdleTimeouts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "timeouts is 0 or 60-86400, unit is second, 0: never idle, + default is 600" + ::= { agentTelnet 2 } + +agentTelnetMaxSessions OBJECT-TYPE + SYNTAX INTEGER (1..4) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTelnet 3 } + +agentFtpServer OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 14 } + +agentTftpServer OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 15 } + +-- the agent trap target group + +agentSendTrap OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 16 } + +agentTrapTargetTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentTrapTargetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + ::= { snmpAgent 17 } + +agentTrapTargetEntry OBJECT-TYPE + SYNTAX AgentTrapTargetEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + INDEX { agentTrapIndex } + ::= { agentTrapTargetTable 1 } + +AgentTrapTargetEntry ::= SEQUENCE { + agentTrapIndex INTEGER, + agentTrapTargetIpAddr IpAddress, + agentTrapTargetComm DisplayString + } + +agentTrapIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + " " + ::= { agentTrapTargetEntry 1 } + +agentTrapTargetIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTrapTargetEntry 2 } + +agentTrapTargetComm OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTrapTargetEntry 3 } + +-- the agent email alert group + +agentEmailAlert OBJECT IDENTIFIER ::= { snmpAgent 18 } + +agentSendEmailAlert OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentEmailAlert 1 } + +agentEmailServerIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentEmailAlert 2 } + +agentRecipientTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentRecipientEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + ::= { agentEmailAlert 3 } + +agentRecipientEntry OBJECT-TYPE + SYNTAX AgentRecipientEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + INDEX { agentRecipientIndex } + ::= { agentRecipientTable 1 } + +AgentRecipientEntry ::= SEQUENCE { + agentRecipientIndex INTEGER, + agentRecipientEmailAddress DisplayString + } + +agentRecipientIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + " " + ::= { agentRecipientEntry 1 } + +agentRecipientEmailAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..47)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentRecipientEntry 2 } + +-- the agent syslog group + +agentSyslog OBJECT IDENTIFIER ::= { snmpAgent 19 } + +agentSyslogOnOff OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslog 1 } + +agentSaveLogsToFlash OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslog 2 } + +agentClearAllLogs OBJECT-TYPE + SYNTAX INTEGER { + none(1), + access(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslog 3 } + +agentSyslogServerTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentSyslogServerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslog 4 } + +agentSyslogServerEntry OBJECT-TYPE + SYNTAX AgentSyslogServerEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + INDEX { agentSyslogServerIndex } + ::= { agentSyslogServerTable 1 } + +AgentSyslogServerEntry ::= SEQUENCE { + agentSyslogServerIndex INTEGER, + agentSyslogServerIpAddr IpAddress + } + +agentSyslogServerIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslogServerEntry 1 } + +agentSyslogServerIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSyslogServerEntry 2 } + +-- the agent secure ip group + +agentSecureIp OBJECT IDENTIFIER ::= { snmpAgent 20 } + +agentSecureIpOnOff OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSecureIp 1 } + +agentSecureIpTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentSecureIpEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + ::= { agentSecureIp 2 } + +agentSecureIpEntry OBJECT-TYPE + SYNTAX AgentSecureIpEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + " " + INDEX { agentSecureIpIndex } + ::= { agentSecureIpTable 1 } + +AgentSecureIpEntry ::= SEQUENCE { + agentSecureIpIndex INTEGER, + agentSecureIpAddr IpAddress + } + +agentSecureIpIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + " " + ::= { agentSecureIpEntry 1 } + +agentSecureIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentSecureIpEntry 2 } + +-- the agent ntp group + +agentTime OBJECT IDENTIFIER ::= { snmpAgent 21 } + +agentNtpClientOnOff OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 1 } + +agentNtpServerIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 2 } + +agentNtpUpdateInterval OBJECT-TYPE + SYNTAX INTEGER (60..86400) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "unit is second" + ::= { agentTime 3 } + +agentTimeZoneName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..8)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 4 } + +agentTimeZoneHoursOffsetWithGMT OBJECT-TYPE + SYNTAX INTEGER (-23..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 5 } + +agentTimeZoneMinutesOffsetWithGMT OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 6 } + +agentSummerTime OBJECT-TYPE + SYNTAX INTEGER { + summer(1), + Sun(2), + lastSun(3), + manual(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 7 } + +agentSummerTimeBeginMonth OBJECT-TYPE + SYNTAX INTEGER { + jan(1), + feb(2), + mar(3), + apr(4), + may(5), + jun(6), + jul(7), + aug(8), + sep(9), + oct(10), + nov(11), + dec(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 8 } + +agentSummerTimeBeginNth OBJECT-TYPE + SYNTAX INTEGER { + first(1), + second(2), + third(3), + fourth(4), + last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 9 } + +agentSummerTimeBeginWeekday OBJECT-TYPE + SYNTAX INTEGER { + sun(1), + mon(2), + tue(3), + wed(4), + thu(5), + fri(6), + sat(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 10 } + +agentSummerTimeBeginHour OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 11 } + +agentSummerTimeBeginMinute OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 12 } + +agentSummerTimeEndMonth OBJECT-TYPE + SYNTAX INTEGER { + jan(1), + feb(2), + mar(3), + apr(4), + may(5), + jun(6), + jul(7), + aug(8), + sep(9), + oct(10), + nov(11), + dec(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 13 } + +agentSummerTimeEndNth OBJECT-TYPE + SYNTAX INTEGER { + first(1), + second(2), + third(3), + fourth(4), + last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 14 } + +agentSummerTimeEndWeekday OBJECT-TYPE + SYNTAX INTEGER { + sun(1), + mon(2), + tue(3), + wed(4), + thu(5), + fri(6), + sat(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 15 } + +agentSummerTimeEndHour OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 16 } + +agentSummerTimeEndMinute OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " " + ::= { agentTime 17 } + +agentSaveRunningCfg OBJECT-TYPE + SYNTAX INTEGER { + none(1), + saveConfiguration(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will save current configuration. + the value will be reset to 1 after succeed." + ::= { snmpAgent 22 } + +agentDefault OBJECT IDENTIFIER ::= { snmpAgent 23 } + +agentKeepCurrentIP OBJECT-TYPE + SYNTAX INTEGER { + none(1), + keepCurrentIP(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will keep current IP configuration + (IP address, Subnet Mask, Default Gateway and Domain Name Servers). + the value will be reset to 1 after succeed." + ::= { agentDefault 1 } + +agentKeepCurrentSNMP OBJECT-TYPE + SYNTAX INTEGER { + none(1), + keepCurrentSNMP(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will keep current SNMP settings + (System information, SNMP communities and SNMP Trap information). + the value will be reset to 1 after succeed." + ::= { agentDefault 2 } + +agentKeepCurrentPort OBJECT-TYPE + SYNTAX INTEGER { + none(1), + keepCurrentPort(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will keep current port settings. + the value will be reset to 1 after succeed." + ::= { agentDefault 3 } + +agentKeepCurrentUser OBJECT-TYPE + SYNTAX INTEGER { + none(1), + keepCurrentUser(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will keep current User settings. + the value will be reset to 1 after succeed." + ::= { agentDefault 4 } + +agentFactoryDefault OBJECT-TYPE + SYNTAX INTEGER { + none(1), + factoryDefault(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will use factory default configuration and reload. + the value will be reset to 1 after succeed." + ::= { agentDefault 5 } + +agentReloadSystem OBJECT-TYPE + SYNTAX INTEGER { + none(1), + reloadSystem(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set this variable will reload system. + the value will be reset to 1 after succeed." + ::= { snmpAgent 24 } + +agentTftpUpgrade OBJECT IDENTIFIER ::= { snmpAgent 25 } + +agentTftpServerIpAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Specify the IP address of the TFTP server where the binary + code is stored." + ::= { agentTftpUpgrade 1 } + +agentUpgradeFileName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Specify the file name of the binary code to be upgraded." + ::= { agentTftpUpgrade 2 } + +agentUpgradeState OBJECT-TYPE + SYNTAX INTEGER { + none(1), + start(2), + inProgress(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Set the variable 1 will start the upgrade process." + ::= { agentTftpUpgrade 3 } + +-- system + +systemTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 1 } + +systemPower1 OBJECT-TYPE + SYNTAX INTEGER { + notplugged(1), + off(2), + on(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 2 } + +systemPower2 OBJECT-TYPE + SYNTAX INTEGER { + notplugged(1), + off(2), + on(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 3 } + +systemFan1 OBJECT-TYPE + SYNTAX INTEGER { + failure(1), + off(2), + on(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 4 } + +systemFan1Selection OBJECT-TYPE + SYNTAX INTEGER { + alwaysOff(1), + alwaysOn(2), + byTemperature(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 5 } + +systemFan1OnTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 6 } + +systemFan1OffTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 7 } + +systemFan2 OBJECT-TYPE + SYNTAX INTEGER { + failure(1), + off(2), + on(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 8 } + +systemFan2Selection OBJECT-TYPE + SYNTAX INTEGER { + alwaysOff(1), + alwaysOn(2), + byTemperature(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 9 } + +systemFan2OnTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 10 } + +systemFan2OffTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 11 } + +-- port table + +portTable OBJECT-TYPE + SYNTAX SEQUENCE OF PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of interface entries." + ::= { lambdatrail 12 } + +portEntry OBJECT-TYPE + SYNTAX PortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A port entry containing objects + below for a port." + INDEX { portId } + ::= { portTable 1 } + +PortEntry ::= SEQUENCE { + portId INTEGER, + portLicensed INTEGER, + portEnabled INTEGER, + portAPSD INTEGER, + portLinePlugged INTEGER, + portLineLink INTEGER, + portLineWavelength INTEGER, + portLineTxPower INTEGER, + portLineRxPower INTEGER, + portLineLaserTemp INTEGER, + portLineLaserBias INTEGER, + portClientPlugged INTEGER, + portClientLink INTEGER, + portClientWavelength INTEGER, + portClientTxPower INTEGER, + portClientRxPower INTEGER, + portClientLaserTemp INTEGER, + portClientLaserBias INTEGER, + portName DisplayString + } + +portId OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A unique value for each interface." + ::= { portEntry 1 } + +portLicensed OBJECT-TYPE + SYNTAX INTEGER { + no(1), + yes(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 2 } + +portEnabled OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 3 } + +portAPSD OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 4 } + +portLinePlugged OBJECT-TYPE + SYNTAX INTEGER { + notPlugged(1), + plugged(2), + notAvailable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 5 } + +portLineLink OBJECT-TYPE + SYNTAX INTEGER { + down(1), + up(2), + notAvailable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 6 } + +portLineWavelength OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is nanometer, -1 means not available" + ::= { portEntry 7 } + +portLineTxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available" + ::= { portEntry 8 } + +portLineRxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available" + ::= { portEntry 9 } + +portLineLaserTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is Celsius degree, -1 means not available" + ::= { portEntry 10 } + +portLineLaserBias OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is mini ampere, -1 means not available" + ::= { portEntry 11 } + +portClientPlugged OBJECT-TYPE + SYNTAX INTEGER { + notPlugged(1), + plugged(2), + notAvailable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 12 } + +portClientLink OBJECT-TYPE + SYNTAX INTEGER { + down(1), + up(2), + notAvailable (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 13 } + +portClientWavelength OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is nanometer, -1 means not available" + ::= { portEntry 14 } + +portClientTxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available" + ::= { portEntry 15 } + +portClientRxPower OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available" + ::= { portEntry 16 } + +portClientLaserTemp OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is Celsius degree, -1 means not available" + ::= { portEntry 17 } + +portClientLaserBias OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "unit is mini ampere, -1 means not available" + ::= { portEntry 18 } + +portName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "" + ::= { portEntry 19 } + +-- + +usablePorts OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "" + ::= { lambdatrail 13 } + +END diff --git a/MIBS/deltanet/Lambdatrail2s-MIB b/MIBS/deltanet/Lambdatrail2s-MIB new file mode 100644 index 0000000..abbd616 --- /dev/null +++ b/MIBS/deltanet/Lambdatrail2s-MIB @@ -0,0 +1,1143 @@ +Lambdatrail2s-MIB DEFINITIONS ::= BEGIN + +IMPORTS + OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, Integer32, + IpAddress + FROM SNMPv2-SMI + DisplayString + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP + FROM SNMPv2-CONF + deltanet + FROM Deltanet-MIB; + +lambdatrail2s MODULE-IDENTITY + LAST-UPDATED "201502100000Z" + ORGANIZATION "DeltaNet AG Switzerland" + CONTACT-INFO "http://www.deltanet.ch" + DESCRIPTION "The MIB module for managing Deltanet Lambdatrail2-S device. + Needs firmware 1.1.0 or higher." + REVISION "201502100000Z" + DESCRIPTION "TFTP-Server removed" + REVISION "201501200000Z" + DESCRIPTION "Adjust structure to be common" + REVISION "201501150000Z" + DESCRIPTION "Initial Lambdatrail2-S Version" + ::= { deltanet 5 } + +-- Deltanet AG Specific Objects -- +lt2sNotifications OBJECT IDENTIFIER ::= { lambdatrail2s 0 } +lt2sAgent OBJECT IDENTIFIER ::= { lambdatrail2s 1 } +lt2sSystem OBJECT IDENTIFIER ::= { lambdatrail2s 2 } +lt2sPorts OBJECT IDENTIFIER ::= { lambdatrail2s 3 } +lt2sInfo OBJECT IDENTIFIER ::= { lambdatrail2s 4 } +lt2sCompliances OBJECT IDENTIFIER ::= { lambdatrail2s 8 } +lt2sGroups OBJECT IDENTIFIER ::= { lambdatrail2s 9 } + + +-- LT3 agent -- +lt2sDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the System Description." + ::= { lt2sAgent 1 } + +lt2sDeviceType OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the Device Type." + ::= { lt2sAgent 2 } + +lt2sHwRevision OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the Device Type." + ::= { lt2sAgent 3 } + +lt2sManufacturingDate OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the Device Type." + ::= { lt2sAgent 4 } + +lt2sSerialNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the serial number of the device." + ::= { lt2sAgent 5 } + +lt2sSystemName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The assigned system name." + ::= { lt2sAgent 6 } + +lt2sSystemLocation OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "System location." + ::= { lt2sAgent 7 } + +lt2sSystemContact OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The responsible person." + ::= { lt2sAgent 8 } + +lt2sSystemUptime OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the time since the last restart of the + management agent." + ::= { lt2sAgent 9 } + +lt2sFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the software version of the agent running image." + ::= { lt2sAgent 10 } + +lt2suCVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the firmware version of the micro controller." + ::= { lt2sAgent 11 } + +lt2sSaveRunningCfg OBJECT-TYPE + SYNTAX INTEGER { none(1), saveConfig(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Set this variable will save current configuration. + The value is set back to 1 after succeed." + ::= { lt2sAgent 12 } + +lt2sResetAgent OBJECT-TYPE + SYNTAX INTEGER { none(1), resetAgent(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Set this variable will reset the agent. + The value is set back to 1 after reset." + ::= { lt2sAgent 13 } + +lt2sSnmpGetCommunity OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The get community, read only." + ::= { lt2sAgent 14 } + +lt2sSnmpSetCommunity OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The set community, read/write." + ::= { lt2sAgent 15 } + +lt2sIp4DHCP OBJECT-TYPE + SYNTAX INTEGER { off(1), on(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "DHCP enable or disable. Default is off" + ::= { lt2sAgent 16 } + +lt2sIp4Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The agent's administrative IP address. The + current operational IP address can be obtained from + the ipAdEntAddr in the ipAddrTable. This parameter + will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { lt2sAgent 17 } + +lt2sIp4Mask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The agent's administrative IP subnet mask. The + current operational IP subnet mask can be obtained from + the ipAdEntMask in the ipAddrTable. This parameter + will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { lt2sAgent 18 } + +lt2sIp4Gateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The agent's administrative default gateway IP address. + The current operational IP default gateway IP address + can be obtained from the ipRouteDest in the ipRouteTable. + This parameter will take effect only after a agent restart or + agent reset. This parameter will always be updated + in the EEPROM." + ::= { lt2sAgent 19 } + +lt2sIp4PrimaryDns OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "First DNS server address." + ::= { lt2sAgent 20 } + +lt2sIp4SecondaryDns OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Second DNS server address." + ::= { lt2sAgent 21 } + +lt2sSnmpServer OBJECT-TYPE + SYNTAX INTEGER { off(1), on(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION " " + ::= { lt2sAgent 22 } + +lt2sHttpServer OBJECT-TYPE + SYNTAX INTEGER { off(1), on(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION " " + ::= { lt2sAgent 23 } + +lt2sTelnetServer OBJECT-TYPE + SYNTAX INTEGER { off(1), on(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION " " + ::= { lt2sAgent 24 } + +lt2sFtpServer OBJECT-TYPE + SYNTAX INTEGER { off(1), on(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION " " + ::= { lt2sAgent 25 } + +-- Management port definitions -- +lt2sMgmtPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF Lt2sMgmtPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A list of management port entries." + ::= { lt2sAgent 26 } + +lt2sMgmtPortEntry OBJECT-TYPE + SYNTAX Lt2sMgmtPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry containing information applicable to + the management ports." + INDEX { lt2sMgmtPortId } + ::= { lt2sMgmtPortTable 1 } + +Lt2sMgmtPortEntry ::= SEQUENCE { + lt2sMgmtPortId Integer32, + lt2sMgmtPortName DisplayString, + lt2sMgmtPortEnable INTEGER, + lt2sMgmtPortLink INTEGER, + lt2sMgmtPortSpeed INTEGER, + lt2sMgmtPortTxBytes Integer32, + lt2sMgmtPortRxBytes Integer32, + lt2sMgmtSfpPlugged INTEGER, + lt2sMgmtSfpVendor DisplayString, + lt2sMgmtSfpType DisplayString, + lt2sMgmtSfpSerial DisplayString, + lt2sMgmtSfpWavelength DisplayString, + lt2sMgmtSfpTxPower Integer32, + lt2sMgmtSfpRxPower Integer32, + lt2sMgmtSfpLaserTemp Integer32, + lt2sMgmtSfpLaserBias Integer32, + lt2sMgmtSfpTxLow Integer32, + lt2sMgmtSfpTxHigh Integer32, + lt2sMgmtSfpRxLow Integer32, + lt2sMgmtSfpRxHigh Integer32 } + +lt2sMgmtPortId OBJECT-TYPE + SYNTAX Integer32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The management port identification. + 1 Inband SFP, 2 LAN1, 3 LAN2." + ::= { lt2sMgmtPortEntry 1 } + +lt2sMgmtPortName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The name of the management port" + ::= { lt2sMgmtPortEntry 2 } + +lt2sMgmtPortEnable OBJECT-TYPE + SYNTAX INTEGER { disabled(1), enabled(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The enabled state of the port." + ::= { lt2sMgmtPortEntry 3 } + +lt2sMgmtPortLink OBJECT-TYPE + SYNTAX INTEGER { down(1), up(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The link state of the management port." + ::= { lt2sMgmtPortEntry 4 } + +lt2sMgmtPortSpeed OBJECT-TYPE + SYNTAX INTEGER { full1000(1), full100(2), half100(3), + full10(4), half10(5), notAvailable(6) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The speed mode of the port." + ::= { lt2sMgmtPortEntry 5 } + +lt2sMgmtPortTxBytes OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + UNITS "sent Bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The total amount of sent bytes." + ::= { lt2sMgmtPortEntry 6 } + +lt2sMgmtPortRxBytes OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + UNITS "sent Bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The total amount of received bytes." + ::= { lt2sMgmtPortEntry 7 } + +lt2sMgmtSfpPlugged OBJECT-TYPE + SYNTAX INTEGER { removed(1), inserted(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP plugged state of the port." + ::= { lt2sMgmtPortEntry 8 } + +lt2sMgmtSfpVendor OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The vendor name of the SFP." + ::= { lt2sMgmtPortEntry 9 } + +lt2sMgmtSfpType OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The vendor part name of the SFP." + ::= { lt2sMgmtPortEntry 10 } + +lt2sMgmtSfpSerial OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The serial number of the SFP." + ::= { lt2sMgmtPortEntry 11 } + +lt2sMgmtSfpWavelength OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The SFP wavelength of the port. If the SFP + is removed the object contains 'NA'." + ::= { lt2sMgmtPortEntry 12 } + +lt2sMgmtSfpTxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The SFP transmit power of the port. If the SFP + is removed, the value is -1." + ::= { lt2sMgmtPortEntry 13 } + +lt2sMgmtSfpRxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The SFP receive power of the port. If the SFP + is removed, the value is -1." + ::= { lt2sMgmtPortEntry 14 } + +lt2sMgmtSfpLaserTemp OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.01 degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The internal temperature of the SFP. If the SFP + is removed, the value is -1." + ::= { lt2sMgmtPortEntry 15 } + +lt2sMgmtSfpLaserBias OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The SFP laser bias in milli ampere. If the SFP + is removed, the value is -1." + ::= { lt2sMgmtPortEntry 16 } + +lt2sMgmtSfpTxLow OBJECT-TYPE + SYNTAX Integer32 (-10..2) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The SFP laser TX low threshold in dBm." + ::= { lt2sMgmtPortEntry 17 } + +lt2sMgmtSfpTxHigh OBJECT-TYPE + SYNTAX Integer32 (-4..8) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The SFP laser TX high threshold in dBm." + ::= { lt2sMgmtPortEntry 18 } + +lt2sMgmtSfpRxLow OBJECT-TYPE + SYNTAX Integer32 (-30..0) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The SFP laser RX low threshold in dBm." + ::= { lt2sMgmtPortEntry 19 } + +lt2sMgmtSfpRxHigh OBJECT-TYPE + SYNTAX Integer32 (-12..6) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The SFP laser RX high threshold in dBm." + ::= { lt2sMgmtPortEntry 20 } + + + -- LT3 system -- +lt2sTemperature OBJECT-TYPE + SYNTAX Integer32 ( 0..80 ) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Shows the ambient temperature." + ::= { lt2sSystem 1 } + +lt2sPowerType OBJECT-TYPE + SYNTAX INTEGER { ac(1), dc(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The device's power supply 1 type." + ::= { lt2sSystem 2 } + +lt2sPowerStatus OBJECT-TYPE + SYNTAX INTEGER { normal(1), failed(2), notPlugged(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The device's power supply 1 status." + ::= { lt2sSystem 3 } + +lt2sPowerFanStatus OBJECT-TYPE + SYNTAX INTEGER { failed(1), on(2), off(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The device's power supply 1's fan status." + ::= { lt2sSystem 4 } + +lt2sPowerFanRPM OBJECT-TYPE + SYNTAX Integer32 (0..20000) + UNITS "revolutions per minute" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The device's power supply 1's fan rounds per minute." + ::= { lt2sSystem 5 } + +lt2sPowerFanMode OBJECT-TYPE + SYNTAX INTEGER { alwaysOff(1), alwaysOn(2), byTemperature(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The device's power supply 1's fan mode." + ::= { lt2sSystem 6 } + +lt2sPowerFanOnTemp OBJECT-TYPE + SYNTAX Integer32 (10..60) + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The device's power supply 1's fan on temperature." + ::= { lt2sSystem 7 } + +lt2sPowerFanOffTemp OBJECT-TYPE + SYNTAX Integer32 (10..60) + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The device's power supply 1's fan off temperature." + ::= { lt2sSystem 8 } + + +-- LT2-S Ports Section -- +lt2sPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF Lt2sPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A list of port table entries." + ::= { lt2sPorts 1 } + +lt2sPortEntry OBJECT-TYPE + SYNTAX Lt2sPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry containing information applicable to a + particular port." + INDEX { lt2sPortId } + ::= { lt2sPortTable 1 } + +Lt2sPortEntry ::= SEQUENCE { + lt2sPortId Integer32, + lt2sPortEnable INTEGER, + lt2sPortApsd INTEGER, + lt2sPortSpeed INTEGER, + lt2sPortReset INTEGER, + lt2sPortLoop INTEGER, + lt2sPortName DisplayString, + lt2sLinePlugged INTEGER, + lt2sLineLink INTEGER, + lt2sLineApsd INTEGER, + lt2sLineType DisplayString, + lt2sLineWavelength DisplayString, + lt2sLineTxPower Integer32, + lt2sLineRxPower Integer32, + lt2sLineLaserTemp Integer32, + lt2sLineLaserBias Integer32, + lt2sLineTxLow Integer32, + lt2sLineTxHigh Integer32, + lt2sLineRxLow Integer32, + lt2sLineRxHigh Integer32, + lt2sClientPlugged INTEGER, + lt2sClientLink INTEGER, + lt2sClientApsd INTEGER, + lt2sClientType DisplayString, + lt2sClientWavelength DisplayString, + lt2sClientTxPower Integer32, + lt2sClientRxPower Integer32, + lt2sClientLaserTemp Integer32, + lt2sClientLaserBias Integer32, + lt2sClientTxLow Integer32, + lt2sClientTxHigh Integer32, + lt2sClientRxLow Integer32, + lt2sClientRxHigh Integer32 } + +lt2sPortId OBJECT-TYPE + SYNTAX Integer32 (1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "A unique value for each port." + ::= { lt2sPortEntry 1 } + +lt2sPortEnable OBJECT-TYPE + SYNTAX INTEGER { disable(1), enable(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The status of the port." + ::= { lt2sPortEntry 2 } + +lt2sPortApsd OBJECT-TYPE + SYNTAX INTEGER { disabled(1), enabled(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The automatic power shut down configuration of the port." + ::= { lt2sPortEntry 3 } + +lt2sPortSpeed OBJECT-TYPE + SYNTAX INTEGER { transparent(1), speed10g(2), speed8g(3), speed16g(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The speed mode of the port." + ::= { lt2sPortEntry 4 } + +lt2sPortReset OBJECT-TYPE + SYNTAX INTEGER { no(1), yes(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reset the port." + ::= { lt2sPortEntry 5 } + +lt2sPortLoop OBJECT-TYPE + SYNTAX INTEGER { off(1), line(2), client(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Set Loop on chosen port." + ::= { lt2sPortEntry 6 } + +lt2sPortName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The name of the port." + ::= { lt2sPortEntry 7 } + +lt2sLinePlugged OBJECT-TYPE + SYNTAX INTEGER { notPlugged(1), plugged(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP plugged state of the port." + ::= { lt2sPortEntry 8 } + +lt2sLineLink OBJECT-TYPE + SYNTAX INTEGER { down(1), up(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP link state of the port." + ::= { lt2sPortEntry 9 } + +lt2sLineApsd OBJECT-TYPE + SYNTAX INTEGER { no(1), yes(2), disabled(3), notAvailable(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The automatic power shut down state of the line port." + ::= { lt2sPortEntry 10 } + +lt2sLineType OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP type of the port." + ::= { lt2sPortEntry 11 } + +lt2sLineWavelength OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP wavelength of the port. If the line SFP is not + plugged in, the object should contain the value of 'NA'." + ::= { lt2sPortEntry 12 } + +lt2sLineTxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP transmit power of the port. If the line SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 13 } + +lt2sLineRxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP receive power of the port. If the line SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 14 } + +lt2sLineLaserTemp OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "degrees Centigrade" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP laser temperature of the port. If the line SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 15 } + +lt2sLineLaserBias OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 Amp" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The line SFP laser bias of the port. If the line SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 16 } + +lt2sLineTxLow OBJECT-TYPE + SYNTAX Integer32 (-10..2) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The line SFP laser TX low threshold of the port." + ::= { lt2sPortEntry 17 } + +lt2sLineTxHigh OBJECT-TYPE + SYNTAX Integer32 (-4..8) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The line SFP laser TX high threshold of the port." + ::= { lt2sPortEntry 18 } + +lt2sLineRxLow OBJECT-TYPE + SYNTAX Integer32 (-30..0) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The line SFP laser RX low threshold of the port." + ::= { lt2sPortEntry 19 } + +lt2sLineRxHigh OBJECT-TYPE + SYNTAX Integer32 (-12..6) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The line SFP laser RX high threshold of the port." + ::= { lt2sPortEntry 20 } + +lt2sClientPlugged OBJECT-TYPE + SYNTAX INTEGER { notPlugged(1), plugged(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP plugged state of the port." + ::= { lt2sPortEntry 21 } + +lt2sClientLink OBJECT-TYPE + SYNTAX INTEGER { down(1), up(2), notAvailable(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP link state of the port." + ::= { lt2sPortEntry 22 } + +lt2sClientApsd OBJECT-TYPE + SYNTAX INTEGER { no(1), yes(2), disabled(3), notAvailable(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The automatic power shut down state of the client port." + ::= { lt2sPortEntry 23 } + +lt2sClientType OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP type of the port." + ::= { lt2sPortEntry 24 } + +lt2sClientWavelength OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP wavelength of the port. If the client SFP + is not plugged in, the object should contain the value of 'NA'." + ::= { lt2sPortEntry 25 } + +lt2sClientTxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP transmit power of the port. If the client SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 26 } + +lt2sClientRxPower OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP receive power of the port. If the client SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 27 } + +lt2sClientLaserTemp OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "degrees Centigrade" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP laser temperature of the port. If the client SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 28 } + +lt2sClientLaserBias OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..2147483647) + UNITS "0.001 Amp" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The client SFP laser bias of the port. If the client SFP + is not plugged in, the object should contain the value of -1." + ::= { lt2sPortEntry 29 } + +lt2sClientTxLow OBJECT-TYPE + SYNTAX Integer32 (-10..2) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The client SFP laser TX low threshold of the port." + ::= { lt2sPortEntry 30 } + +lt2sClientTxHigh OBJECT-TYPE + SYNTAX Integer32 (-4..8) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The client SFP laser TX high threshold of the port." + ::= { lt2sPortEntry 31 } + +lt2sClientRxLow OBJECT-TYPE + SYNTAX Integer32 (-30..0) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The client SFP laser RX low threshold of the port." + ::= { lt2sPortEntry 32 } + +lt2sClientRxHigh OBJECT-TYPE + SYNTAX Integer32 (-12..6) + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The client SFP laser RX high threshold of the port." + ::= { lt2sPortEntry 33 } + + +-- LT2-S Trap Information -- +lt2sTrapDetails OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The trap description." + ::= { lt2sInfo 1 } + +-- LT2-S Trap Section -- +lt2sMgmtStartup NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "The agent has started up and is running." + ::= { lt2sNotifications 1 } + +lt2sMgmtAuthenticationFailure NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "Login has failed." + ::= { lt2sNotifications 2 } + +lt2sTemperatureHigh NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "Device temperature is high." + ::= { lt2sNotifications 3 } + +lt2sTemperatureNormal NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "Device temperature is back to normal. + Lower than 40 degrees celsius." + ::= { lt2sNotifications 4 } + +lt2sPowerSupplyPluggedIn NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A power is plugged in." + ::= { lt2sNotifications 5 } + +lt2sPowerSupplyPluggedOut NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A power is plugged out." + ::= { lt2sNotifications 6 } + +lt2sPowerNormal NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A power goes on." + ::= { lt2sNotifications 7 } + +lt2sPowerFailure NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A power goes off." + ::= { lt2sNotifications 8 } + +lt2sFanOn NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A fan goes on." + ::= { lt2sNotifications 9 } + +lt2sFanOff NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A fan goes off." + ::= { lt2sNotifications 10 } + +lt2sFanFailure NOTIFICATION-TYPE + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "A fan goes to failure." + ::= { lt2sNotifications 11 } + +lt2sMgmtSfpPluggedIn NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "SFP transceiver is plugged in on management port." + ::= { lt2sNotifications 12 } + +lt2sMgmtSfpPluggedOut NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "SFP transceiver is plugged out on management port." + ::= { lt2sNotifications 13 } + +lt2sMgmtLinkUp NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "A link goes up in one of the management ports." + ::= { lt2sNotifications 14 } + +lt2sMgmtLinkDown NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "A link goes down in one of the management ports." + ::= { lt2sNotifications 15 } + +lt2sMgmtTxLow NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver TX power is low in the management port." + ::= { lt2sNotifications 16 } + +lt2sMgmtTxHigh NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver TX power is high in the management port." + ::= { lt2sNotifications 17 } + +lt2sMgmtTxNormal NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver TX power is normal in the management port." + ::= { lt2sNotifications 18 } + +lt2sMgmtRxLow NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver RX power is low in the management port." + ::= { lt2sNotifications 19 } + +lt2sMgmtRxHigh NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver RX power is high in the management port." + ::= { lt2sNotifications 20 } + +lt2sMgmtRxNormal NOTIFICATION-TYPE + OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName } + STATUS current + DESCRIPTION "Transceiver RX power is normal in the management port." + ::= { lt2sNotifications 21 } + +lt2sPortEnabled NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "Port is administrative enabled." + ::= { lt2sNotifications 22 } + +lt2sPortDisabled NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "Port is administrative disabled." + ::= { lt2sNotifications 23 } + +lt2sPortReseted NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A reset in one of the ports." + ::= { lt2sNotifications 24 } + +lt2sPortThermalShutdown NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A thermal shut down in one of the ports." + ::= { lt2sNotifications 25 } + +lt2sPortThermalWakeup NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A thermal wakeup in one of the ports." + ::= { lt2sNotifications 26 } + +lt2sLinePluggedIn NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver is plugged in, on one of the ports." + ::= { lt2sNotifications 27 } + +lt2sClientPluggedIn NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver is plugged in, on one of the ports." + ::= { lt2sNotifications 28 } + +lt2sLinePluggedOut NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver is plugged out, on one of the ports." + ::= { lt2sNotifications 29 } + +lt2sClientPluggedOut NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver is plugged out, on one of the ports." + ::= { lt2sNotifications 30 } + +lt2sLineLinkUp NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver's link goes up in one of the ports." + ::= { lt2sNotifications 31 } + +lt2sClientLinkUp NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver's link goes up in one of the ports." + ::= { lt2sNotifications 32 } + +lt2sLineLinkDown NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver's link goes down in one of the ports." + ::= { lt2sNotifications 33 } + +lt2sClientLinkDown NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver's link goes down in one of the ports." + ::= { lt2sNotifications 34 } + +lt2sLineLoopOn NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A Line loop is activated in one of the ports." + ::= { lt2sNotifications 35 } + +lt2sLineLoopOff NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A Line loop is turned off in one of the ports." + ::= { lt2sNotifications 36 } + +lt2sClientLoopOn NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A Client loop is activated in one of the ports." + ::= { lt2sNotifications 37 } + +lt2sClientLoopOff NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A Client loop is turned off in one of the ports." + ::= { lt2sNotifications 38 } + +lt2sPortTxLow NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver TX power is low in one of the ports." + ::= { lt2sNotifications 39 } + +lt2sPortTxHigh NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver TX power is high in one of the ports." + ::= { lt2sNotifications 40 } + +lt2sPortTxNormal NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver TX power is normal in one of the ports." + ::= { lt2sNotifications 41 } + +lt2sPortRxLow NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver RX power is low in one of the ports." + ::= { lt2sNotifications 42 } + +lt2sPortRxHigh NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver RX power is high in one of the ports." + ::= { lt2sNotifications 43 } + +lt2sPortRxNormal NOTIFICATION-TYPE + OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName } + STATUS current + DESCRIPTION "A SFP transceiver RX power is normal in one of the ports." + ::= { lt2sNotifications 44 } + + +lt2sCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION "Describes the requirements for conformance to the + Lambdatrail2 MIB part." + MODULE + MANDATORY-GROUPS { lt2sAgentGroup, lt2sSystemGroup, lt2sPortsGroup, + lt2sInfoGroup, lt2sNotificationGroup } + ::= { lt2sCompliances 1 } + +lt2sAgentGroup OBJECT-GROUP + OBJECTS { lt2sDescription, lt2sDeviceType, lt2sHwRevision, lt2sManufacturingDate, + lt2sSerialNumber, lt2sSystemName, lt2sSystemLocation, lt2sSystemContact, + lt2sSystemUptime, lt2sFirmwareVersion, lt2suCVersion, lt2sSaveRunningCfg, + lt2sResetAgent, lt2sSnmpGetCommunity, lt2sSnmpSetCommunity, lt2sIp4DHCP, + lt2sIp4Address, lt2sIp4Mask, lt2sIp4Gateway, lt2sIp4PrimaryDns, + lt2sIp4SecondaryDns, lt2sSnmpServer, lt2sHttpServer, lt2sTelnetServer, + lt2sFtpServer, lt2sMgmtPortId, lt2sMgmtPortName, + lt2sMgmtPortEnable, lt2sMgmtPortLink, lt2sMgmtPortSpeed, lt2sMgmtPortTxBytes, + lt2sMgmtPortRxBytes, lt2sMgmtSfpPlugged, lt2sMgmtSfpVendor, lt2sMgmtSfpType, + lt2sMgmtSfpSerial, lt2sMgmtSfpWavelength, lt2sMgmtSfpTxPower, lt2sMgmtSfpRxPower, + lt2sMgmtSfpLaserTemp, lt2sMgmtSfpLaserBias, lt2sMgmtSfpTxLow, lt2sMgmtSfpTxHigh, + lt2sMgmtSfpRxLow, lt2sMgmtSfpRxHigh } + STATUS current + DESCRIPTION "Grouping all LT2-S Agent parameters." + ::= { lt2sGroups 1 } + +lt2sSystemGroup OBJECT-GROUP + OBJECTS { lt2sTemperature, lt2sPowerType, lt2sPowerStatus, lt2sPowerFanStatus, + lt2sPowerFanRPM, lt2sPowerFanMode, lt2sPowerFanOnTemp, lt2sPowerFanOffTemp } + STATUS current + DESCRIPTION "Grouping all LT2-S system parameters." + ::= { lt2sGroups 2 } + +lt2sPortsGroup OBJECT-GROUP + OBJECTS { lt2sPortId, lt2sPortEnable, lt2sPortApsd, lt2sPortSpeed, lt2sPortReset, + lt2sPortLoop, lt2sPortName, lt2sLinePlugged, lt2sLineType, lt2sLineLink, + lt2sLineApsd, lt2sLineWavelength, lt2sLineTxPower, lt2sLineRxPower, + lt2sLineLaserTemp, lt2sLineLaserBias, lt2sClientPlugged, lt2sClientType, + lt2sClientLink, lt2sClientApsd, lt2sClientWavelength, lt2sClientTxPower, + lt2sClientRxPower, lt2sClientLaserTemp, lt2sClientLaserBias, lt2sLineTxLow, + lt2sLineTxHigh, lt2sLineRxLow, lt2sLineRxHigh, lt2sClientTxLow, lt2sClientTxHigh, + lt2sClientRxLow, lt2sClientRxHigh } + STATUS current + DESCRIPTION "Grouping all LT2-S port parameters." + ::= { lt2sGroups 3 } + +lt2sInfoGroup OBJECT-GROUP + OBJECTS { lt2sTrapDetails } + STATUS current + DESCRIPTION "Grouping all LT2-S info parameters." + ::= { lt2sGroups 4 } + +lt2sNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { lt2sMgmtStartup, lt2sMgmtAuthenticationFailure, lt2sTemperatureHigh, + lt2sTemperatureNormal, lt2sPowerSupplyPluggedIn, lt2sPowerSupplyPluggedOut, + lt2sPowerNormal, lt2sPowerFailure, lt2sFanOn, lt2sFanOff, lt2sFanFailure, + lt2sPortEnabled, lt2sPortDisabled, lt2sPortReseted, lt2sPortThermalShutdown, + lt2sPortThermalWakeup, lt2sMgmtSfpPluggedIn, lt2sLinePluggedIn, lt2sClientPluggedIn, + lt2sMgmtSfpPluggedOut, lt2sLinePluggedOut, lt2sClientPluggedOut, lt2sMgmtLinkUp, + lt2sLineLinkUp, lt2sClientLinkUp, lt2sMgmtLinkDown, lt2sLineLinkDown, + lt2sClientLinkDown, lt2sLineLoopOn, lt2sLineLoopOff, lt2sClientLoopOn, + lt2sClientLoopOff, lt2sMgmtTxLow, lt2sPortTxLow, lt2sMgmtTxHigh, lt2sPortTxHigh, + lt2sMgmtTxNormal, lt2sPortTxNormal, lt2sMgmtRxLow, lt2sPortRxLow, lt2sMgmtRxHigh, + lt2sPortRxHigh, lt2sMgmtRxNormal, lt2sPortRxNormal } + STATUS current + DESCRIPTION "All the Traps the Lambdatrail2-S supports." + ::= { lt2sGroups 5 } + +END -- cgit v1.2.3