From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB | 909 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 909 insertions(+) create mode 100644 MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB (limited to 'MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB') diff --git a/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB b/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB new file mode 100644 index 0000000..fb36f90 --- /dev/null +++ b/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB @@ -0,0 +1,909 @@ +-- +-- sle-mpls-tp-tunnel-mib.mib +-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 +-- Friday, January 15, 2016 at 13:52:12 +-- + + SLE-MPLS-TP-TUNNEL-MIB DEFINITIONS ::= BEGIN + + IMPORTS + sleMgmt + FROM DASAN-SMI + ifGeneralInformationGroup, ifCounterDiscontinuityGroup, InterfaceIndexOrZero + FROM IF-MIB + MplsCcId, MplsIccId + FROM MPLS-TC-EXT-STD-MIB + mplsStdMIB, MplsLabel + FROM MPLS-TC-STD-MIB + SleControlStatusType, SleControlRequestResultType + FROM SLE-TC-MIB + zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32, + OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY + FROM SNMPv2-SMI + MacAddress + FROM SNMPv2-TC; + + + sleMplsTpTunnel MODULE-IDENTITY + LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT + ORGANIZATION + "Multiprotocol Label Switching (MPLS) Working Group" + CONTACT-INFO + "Gyerok Kwon + Dasan Networks + Email: grkwon@dasannetworks.com + + Kantharaj B M + Dasan Networks + Email: kanth@dasannetworks.com + + DongChel Shin (Chris) + Dasan Networks + Email: dchshin@dasannetworks.com + + Comments about this document should be emailed + directly to the Dasan support email ID at + support@dasannetworks.com." + DESCRIPTION + "Copyright (C) The Internet Society (2004). The + initial version of this MIB module was published + in RFC 3812. For full legal notices see the RFC + itself or see: http://www.ietf.org/copyrights/ianamib.html + + This MIB module contains managed object definitions + for MPLS Traffic Engineering (TE) as defined in: + 1. Extensions to RSVP for LSP Tunnels, Awduche et + al, RFC 3209, December 2001 + 2. Constraint-Based LSP Setup using LDP, Jamoussi + + (Editor), RFC 3212, January 2002 + 3. Requirements for Traffic Engineering Over MPLS, + Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., + and J. McManus, [RFC2702], September 1999" + REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT + DESCRIPTION + "Initial version issued as part of RFC 3812." + ::= { sleMpls 14 } + + + + +-- +-- Node definitions +-- + + sleMpls OBJECT-IDENTITY + STATUS current + DESCRIPTION + "SLE MPLS." + ::= { sleMgmt 16 } + + + sleMplsTpTunnelCfg OBJECT IDENTIFIER ::= { sleMplsTpTunnel 1 } + + + sleMplsTpTunnelCfgInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF SleMplsTpTunnelCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The mplsTunnelTable allows new MPLS tunnels to be + created between an LSR and a remote endpoint, and + existing tunnels to be reconfigured or removed. + Note that only point-to-point tunnel segments are + supported, although multipoint-to-point and point- + to-multipoint connections are supported by an LSR + acting as a cross-connect. Each MPLS tunnel can + thus have one out-segment originating at this LSR + and/or one in-segment terminating at this LSR." + ::= { sleMplsTpTunnelCfg 1 } + + + sleMplsTpTunnelCfgInfoEntry OBJECT-TYPE + SYNTAX SleMplsTpTunnelCfgInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in this table represents an MPLS tunnel. + An entry can be created by a network administrator + or by an SNMP agent as instructed by an MPLS + signalling protocol. Whenever a new entry is + created with mplsTunnelIsIf set to true(1), then a + corresponding entry is created in ifTable as well + (see RFC 2863). The ifType of this entry is + mplsTunnel(150). + + A tunnel entry needs to be uniquely identified across + a MPLS network. Indices mplsTunnelIndex and + mplsTunnelInstance uniquely identify a tunnel on + the LSR originating the tunnel. To uniquely + identify a tunnel across an MPLS network requires + + index mplsTunnelIngressLSRId. The last index + mplsTunnelEgressLSRId is useful in identifying all + instances of a tunnel that terminate on the same + egress LSR." + REFERENCE + "1. RFC 2863 - The Interfaces Group MIB, McCloghrie, + K., and F. Kastenholtz, June 2000 " + INDEX { sleMplsTpTunnelCfgInfoIndex } + ::= { sleMplsTpTunnelCfgInfoTable 1 } + + + SleMplsTpTunnelCfgInfoEntry ::= + SEQUENCE { + sleMplsTpTunnelCfgInfoIndex + Unsigned32, + sleMplsTpTunnelCfgInfoName + OCTET STRING, + sleMplsTpTunnelCfgInfoId + Unsigned32, + sleMplsTpTunnelCfgInfoSrcIdType + INTEGER, + sleMplsTpTunnelCfgInfoSrcGId + Unsigned32, + sleMplsTpTunnelCfgInfoSrcCc + MplsCcId, + sleMplsTpTunnelCfgInfoSrcIcc + MplsIccId, + sleMplsTpTunnelCfgInfoSrcNodeId + IpAddress, + sleMplsTpTunnelCfgInfoDestIdType + INTEGER, + sleMplsTpTunnelCfgInfoDestGId + Unsigned32, + sleMplsTpTunnelCfgInfoDestCc + MplsCcId, + sleMplsTpTunnelCfgInfoDestIcc + MplsIccId, + sleMplsTpTunnelCfgInfoDestNodeId + IpAddress, + sleMplsTpTunnelCfgInfoMode + INTEGER, + sleMplsTpTunnelCfgInfoFwdInLabel + MplsLabel, + sleMplsTpTunnelCfgInfoFwdInIfIndex + InterfaceIndexOrZero, + sleMplsTpTunnelCfgInfoFwdOperation + INTEGER, + sleMplsTpTunnelCfgInfoFwdOutLabel + MplsLabel, + sleMplsTpTunnelCfgInfoFwdOutIfIndex + InterfaceIndexOrZero, + sleMplsTpTunnelCfgInfoFwdOutMac + MacAddress, + sleMplsTpTunnelCfgInfoRevInLabel + MplsLabel, + sleMplsTpTunnelCfgInfoRevInIfIndex + InterfaceIndexOrZero, + sleMplsTpTunnelCfgInfoRevOperation + INTEGER, + sleMplsTpTunnelCfgInfoRevOutLabel + MplsLabel, + sleMplsTpTunnelCfgInfoRevOutIfIndex + InterfaceIndexOrZero, + sleMplsTpTunnelCfgInfoRevOutMac + MacAddress, + sleMplsTpTunnelCfgInfoState + INTEGER, + sleMplsTpTunnelCfgInfoRole + INTEGER, + sleMplsTpTunnelCfgInfoAssociateTnlName + OCTET STRING, + sleMplsTpTunnelCfgInfoDescription + OCTET STRING, + sleMplsTpTunnelCfgInfoHlspRole + INTEGER, + sleMplsTpTunnelCfgInfoHlspServerTunnelName + OCTET STRING, + sleMplsTpTunnelCfgInfoQosPolicyName + OCTET STRING + } + + sleMplsTpTunnelCfgInfoIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value which identify an entry in this table." + ::= { sleMplsTpTunnelCfgInfoEntry 1 } + + + sleMplsTpTunnelCfgInfoName OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The canonical name assigned to the tunnel. This name + can be used to refer to the tunnel on the LSR's + console port. If mplsTunnelIsIf is set to true + then the ifName of the interface corresponding to + this tunnel should have a value equal to + mplsTunnelName. Also see the description of ifName + in RFC 2863." + REFERENCE + "RFC 2863 - The Interfaces Group MIB, McCloghrie, K., + and F. Kastenholtz, June 2000." + DEFVAL { "" } + ::= { sleMplsTpTunnelCfgInfoEntry 2 } + + + sleMplsTpTunnelCfgInfoId OBJECT-TYPE + SYNTAX Unsigned32 (1..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Uniquely identifies a set of tunnel instances + between a pair of ingress and egress LSRs. + Managers should obtain new values for row + creation in this table by reading + mplsTunnelIndexNext. When + the MPLS signalling protocol is rsvp(2) this value + SHOULD be equal to the value signaled in the + Tunnel Id of the Session object. When the MPLS + signalling protocol is crldp(3) this value + SHOULD be equal to the value signaled in the + LSP ID." + ::= { sleMplsTpTunnelCfgInfoEntry 3 } + + + sleMplsTpTunnelCfgInfoSrcIdType OBJECT-TYPE + SYNTAX INTEGER + { + ietf(1), + itut(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the ietf or itut type." + ::= { sleMplsTpTunnelCfgInfoEntry 4 } + + + sleMplsTpTunnelCfgInfoSrcGId OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to display the GlobalID of IETF" + ::= { sleMplsTpTunnelCfgInfoEntry 5 } + + + sleMplsTpTunnelCfgInfoSrcCc OBJECT-TYPE + SYNTAX MplsCcId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to display the Source CC-ID of ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 6 } + + + sleMplsTpTunnelCfgInfoSrcIcc OBJECT-TYPE + SYNTAX MplsIccId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to set the Source ICC-ID of ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 7 } + + + sleMplsTpTunnelCfgInfoSrcNodeId OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to display the Source Node ID of IETF and ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 8 } + + + sleMplsTpTunnelCfgInfoDestIdType OBJECT-TYPE + SYNTAX INTEGER + { + ietf(1), + itut(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the ietf or itut type." + ::= { sleMplsTpTunnelCfgInfoEntry 9 } + + + sleMplsTpTunnelCfgInfoDestGId OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to set the Destination GlobalID of IETF" + ::= { sleMplsTpTunnelCfgInfoEntry 10 } + + + sleMplsTpTunnelCfgInfoDestCc OBJECT-TYPE + SYNTAX MplsCcId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to display the Destination CC-ID of ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 11 } + + + sleMplsTpTunnelCfgInfoDestIcc OBJECT-TYPE + SYNTAX MplsIccId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to set the Destination ICC-ID of ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 12 } + + + sleMplsTpTunnelCfgInfoDestNodeId OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Object is used to display the Destination Node ID of IETF and ITUT" + ::= { sleMplsTpTunnelCfgInfoEntry 13 } + + + sleMplsTpTunnelCfgInfoMode OBJECT-TYPE + SYNTAX INTEGER + { + none(0), + unidirectional(1), + bidirectional(2), + corouted(3), + associate(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Tunnel Mode" + ::= { sleMplsTpTunnelCfgInfoEntry 14 } + + + sleMplsTpTunnelCfgInfoFwdInLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward In Label. + The lable range is 0 to 1048575. Here 0 to 15 are + reserved labels. User allowed range is 16 to 1048575.. + + The default value 1048576 is invalid label " + DEFVAL { 1048576 } + ::= { sleMplsTpTunnelCfgInfoEntry 15 } + + + sleMplsTpTunnelCfgInfoFwdInIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Forward IN Interface index " + ::= { sleMplsTpTunnelCfgInfoEntry 16 } + + + sleMplsTpTunnelCfgInfoFwdOperation OBJECT-TYPE + SYNTAX INTEGER + { + none(0), + push(1), + pop(2), + swap(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Forward Ilm OPeration ." + ::= { sleMplsTpTunnelCfgInfoEntry 17 } + + + sleMplsTpTunnelCfgInfoFwdOutLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward In Label. + The lable range is 0 to 1048575. Here 0 to 15 are + reserved labels. User allowed range is 16 to 1048575. + + The default value 1048576 is invalid label " + DEFVAL { 1048576 } + ::= { sleMplsTpTunnelCfgInfoEntry 18 } + + + sleMplsTpTunnelCfgInfoFwdOutIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Forward OUT Interface index " + ::= { sleMplsTpTunnelCfgInfoEntry 19 } + + + sleMplsTpTunnelCfgInfoFwdOutMac OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward OUT MAC ADDRESS " + ::= { sleMplsTpTunnelCfgInfoEntry 20 } + + + sleMplsTpTunnelCfgInfoRevInLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward In Label. + The lable range is 0 to 1048575. Here 0 to 15 are + reserved labels. User allowed range is 16 to 1048575. + + The default value 1048576 is invalid label " + DEFVAL { 1048576 } + ::= { sleMplsTpTunnelCfgInfoEntry 21 } + + + sleMplsTpTunnelCfgInfoRevInIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Reverse IN Interface index " + ::= { sleMplsTpTunnelCfgInfoEntry 22 } + + + sleMplsTpTunnelCfgInfoRevOperation OBJECT-TYPE + SYNTAX INTEGER + { + none(0), + push(1), + pop(2), + swap(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Reverse Ilm OPeration ." + ::= { sleMplsTpTunnelCfgInfoEntry 23 } + + + sleMplsTpTunnelCfgInfoRevOutLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward In Label. + The lable range is 0 to 1048575. Here 0 to 15 are + reserved labels. User allowed range is 16 to 1048575. + + The default value 1048576 is invalid label " + DEFVAL { 1048576 } + ::= { sleMplsTpTunnelCfgInfoEntry 24 } + + + sleMplsTpTunnelCfgInfoRevOutIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Reverse OUT Interface index " + ::= { sleMplsTpTunnelCfgInfoEntry 25 } + + + sleMplsTpTunnelCfgInfoRevOutMac OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to display the Forward OUT MAC ADDRESS ." + ::= { sleMplsTpTunnelCfgInfoEntry 26 } + + + sleMplsTpTunnelCfgInfoState OBJECT-TYPE + SYNTAX INTEGER + { + up(1), + down(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is to display status of the tunnel." + ::= { sleMplsTpTunnelCfgInfoEntry 27 } + + + sleMplsTpTunnelCfgInfoRole OBJECT-TYPE + SYNTAX INTEGER + { + source(0), + transist(1), + destination(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is to display Role of the tunnel." + ::= { sleMplsTpTunnelCfgInfoEntry 28 } + + + sleMplsTpTunnelCfgInfoAssociateTnlName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object to display associate of reverse tunnel." + ::= { sleMplsTpTunnelCfgInfoEntry 29 } + + + sleMplsTpTunnelCfgInfoDescription OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description." + ::= { sleMplsTpTunnelCfgInfoEntry 30 } + + + sleMplsTpTunnelCfgInfoHlspRole OBJECT-TYPE + SYNTAX INTEGER + { + server(1), + client(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Hlsp Tunnel. whether the tunnel is Server or client. + server (1) :- To set the Server Tunnel + client(2) :- To set the Client Tunnel ." + ::= { sleMplsTpTunnelCfgInfoEntry 31 } + + + sleMplsTpTunnelCfgInfoHlspServerTunnelName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the server TunnelName, + when sleMplsTpTunnelCfgControlHlspOption as a client ." + ::= { sleMplsTpTunnelCfgInfoEntry 32 } + + + sleMplsTpTunnelCfgInfoQosPolicyName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set the Qos Policy name." + ::= { sleMplsTpTunnelCfgInfoEntry 33 } + + + sleMplsTpTunnelCfgControl OBJECT IDENTIFIER ::= { sleMplsTpTunnelCfg 2 } + + + sleMplsTpTunnelCfgControlRequest OBJECT-TYPE + SYNTAX INTEGER + { + createMplsTpTunnelEntry(1), + deleteMplsTpTunnelEntry(2), + setMplsTpTunnelMode(3), + setNhlfe(4), + setIlmPop(5), + setIlmSwap(6), + setAssociateTunnel(7), + unsetNhlfe(8), + unsetIlmPop(9), + unsetIlmSwap(10), + unsetAssociateTunnel(11), + setDescription(12), + setHlspServerLsp(13), + setHlspClientLsp(14), + unsetHlspServerLsp(15), + unsetHlspClientLsp(16), + setTunnelQosPolicyName(17), + unsetTunnelQosPolicyName(18) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object holds the possible read-write columns that can be + modified in the Tunnel table. For each read-write column of + Tunnel table, a Set Operation controlvalue is added in this object." + ::= { sleMplsTpTunnelCfgControl 1 } + + + sleMplsTpTunnelCfgControlStatus OBJECT-TYPE + SYNTAX SleControlStatusType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object displays the status of the configuration done." + ::= { sleMplsTpTunnelCfgControl 2 } + + + sleMplsTpTunnelCfgControlTimer OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is based on the SLE style where a timer is configured + for every control table." + ::= { sleMplsTpTunnelCfgControl 3 } + + + sleMplsTpTunnelCfgControlTimeStamp OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the time at which the configuration is done." + ::= { sleMplsTpTunnelCfgControl 4 } + + + sleMplsTpTunnelCfgControlReqResult OBJECT-TYPE + SYNTAX SleControlRequestResultType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The standard result of the SET operation is stored here." + ::= { sleMplsTpTunnelCfgControl 5 } + + + sleMplsTpTunnelCfgControlName OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The canonical name assigned to the tunnel. This name + can be used to refer to the tunnel on the LSR's + console port. If mplsTunnelIsIf is set to true + then the ifName of the interface corresponding to + this tunnel should have a value equal to + SlemplsTunnelName. Also see the description of ifName + in RFC 2863." + REFERENCE + "RFC 2863 - The Interfaces Group MIB, McCloghrie, K., + and F. Kastenholtz, June 2000." + DEFVAL { "" } + ::= { sleMplsTpTunnelCfgControl 6 } + + + sleMplsTpTunnelCfgControlId OBJECT-TYPE + SYNTAX Unsigned32 (1..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the tunnel Id ." + ::= { sleMplsTpTunnelCfgControl 7 } + + + sleMplsTpTunnelCfgControlSrcIdType OBJECT-TYPE + SYNTAX INTEGER + { + ietf(1), + itut(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the ietf or itut type." + ::= { sleMplsTpTunnelCfgControl 8 } + + + sleMplsTpTunnelCfgControlSrcGId OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the source Global-Id for IETF ." + ::= { sleMplsTpTunnelCfgControl 9 } + + + sleMplsTpTunnelCfgControlSrcCc OBJECT-TYPE + SYNTAX MplsCcId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the source CC-ID for ITUT." + ::= { sleMplsTpTunnelCfgControl 10 } + + + sleMplsTpTunnelCfgControlSrcIcc OBJECT-TYPE + SYNTAX MplsIccId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Source ICC-ID for ITUT." + ::= { sleMplsTpTunnelCfgControl 11 } + + + sleMplsTpTunnelCfgControlSrcNodeId OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Source Node-Id for IETF and ITUT" + ::= { sleMplsTpTunnelCfgControl 12 } + + + sleMplsTpTunnelCfgControlDestIdType OBJECT-TYPE + SYNTAX INTEGER + { + ietf(1), + itut(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the ietf or itut type." + ::= { sleMplsTpTunnelCfgControl 13 } + + + sleMplsTpTunnelCfgControlDestGId OBJECT-TYPE + SYNTAX Unsigned32 (1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Destination Global-Id for IETF ." + ::= { sleMplsTpTunnelCfgControl 14 } + + + sleMplsTpTunnelCfgControlDestCc OBJECT-TYPE + SYNTAX MplsCcId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Destination CC-ID for ITUT." + ::= { sleMplsTpTunnelCfgControl 15 } + + + sleMplsTpTunnelCfgControlDestIcc OBJECT-TYPE + SYNTAX MplsIccId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Destination ICC-ID for ITUT." + ::= { sleMplsTpTunnelCfgControl 16 } + + + sleMplsTpTunnelCfgControlDestNodeId OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Destination NodeID for IETF + and ITUT." + ::= { sleMplsTpTunnelCfgControl 17 } + + + sleMplsTpTunnelCfgControlMode OBJECT-TYPE + SYNTAX INTEGER + { + unidirectional(1), + bidirectional(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Tunnel mode ." + ::= { sleMplsTpTunnelCfgControl 18 } + + + sleMplsTpTunnelCfgControlPath OBJECT-TYPE + SYNTAX INTEGER + { + forwardPath(1), + reversePath(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to Set the forward path and reverse path + tunnel." + ::= { sleMplsTpTunnelCfgControl 19 } + + + sleMplsTpTunnelCfgControlInLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Inlabel. " + ::= { sleMplsTpTunnelCfgControl 20 } + + + sleMplsTpTunnelCfgControlInInterface OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Ininterface index." + ::= { sleMplsTpTunnelCfgControl 21 } + + + sleMplsTpTunnelCfgControlOperation OBJECT-TYPE + SYNTAX INTEGER + { + push(1), + pop(2), + swap(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the operation of Tuunel " + ::= { sleMplsTpTunnelCfgControl 22 } + + + sleMplsTpTunnelCfgControlOutLabel OBJECT-TYPE + SYNTAX MplsLabel + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the outlabel. " + ::= { sleMplsTpTunnelCfgControl 23 } + + + sleMplsTpTunnelCfgControlOutInterface OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the outerinterface index." + ::= { sleMplsTpTunnelCfgControl 24 } + + + sleMplsTpTunnelCfgControlOutMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to Set the Out MacAddress ." + ::= { sleMplsTpTunnelCfgControl 25 } + + + sleMplsTpTunnelCfgControlAssociateTnlName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to Associated Forward tunnel and reverse tunnel + with reverse tunnel name ." + ::= { sleMplsTpTunnelCfgControl 26 } + + + sleMplsTpTunnelCfgControlDescription OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Description." + ::= { sleMplsTpTunnelCfgControl 27 } + + + sleMplsTpTunnelCfgControlHlspSeverTunnelName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the server Tunnel name for associating server and client." + ::= { sleMplsTpTunnelCfgControl 28 } + + + sleMplsTpTunnelCfgControlQosPolicyName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to set the Qos Policy name." + ::= { sleMplsTpTunnelCfgControl 29 } + + + + END + +-- +-- sle-mpls-tp-tunnel-mib.mib +-- -- cgit v1.2.3