From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB | 205 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 205 insertions(+) create mode 100644 MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB (limited to 'MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB') diff --git a/MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB b/MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB new file mode 100644 index 0000000..6218cef --- /dev/null +++ b/MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB @@ -0,0 +1,205 @@ +-- +-- sle-mpls-tp-pro-if-mib.mib +-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 +-- Tuesday, January 12, 2016 at 14:08:09 +-- + + SLE-MPLS-TP-PRO-IF-MIB DEFINITIONS ::= BEGIN + + IMPORTS + sleMgmt + FROM DASAN-SMI + mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId + FROM MPLS-TE-STD-MIB + SleControlStatusType, SleControlRequestResultType + FROM SLE-TC-MIB + zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32, + OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY + FROM SNMPv2-SMI; + + + sleMplsTpNode MODULE-IDENTITY + LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT + ORGANIZATION + "Multiprotocol Label Switching (MPLS) Working Group" + CONTACT-INFO + "Gyerok Kwon + Dasan Networks + Email: grkwon@dasannetworks.com + + Kantharaj B M + Dasan Networks + Email: kanth@dasannetworks.com + + DongChel Shin (Chris) + Dasan Networks + Email: dchshin@dasannetworks.com + + Comments about this document should be emailed + directly to the Dasan support email ID at + support@dasannetworks.com." + DESCRIPTION + "Copyright (c) 2012 IETF Trust and the persons identified + as the document authors. All rights reserved. + + This MIB module contains generic object definitions for + MPLS Traffic Engineering in transport networks." + REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT + DESCRIPTION + "MPLS_TP node configuration table" + ::= { sleMpls 13 } + + + + +-- +-- Node definitions +-- + + sleMpls OBJECT-IDENTITY + STATUS current + DESCRIPTION + "SLE MPLS." + ::= { sleMgmt 16 } + + + sleMplsTpProIf OBJECT IDENTIFIER ::= { sleMplsTpNode 2 } + + + sleMplsTpProIfInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF SleMplsTpProIfInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { sleMplsTpProIf 1 } + + + sleMplsTpProIfInfoEntry OBJECT-TYPE + SYNTAX SleMplsTpProIfInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { sleMplsTPProIfInfoIfIndex } + ::= { sleMplsTpProIfInfoTable 1 } + + + SleMplsTpProIfInfoEntry ::= + SEQUENCE { + sleMplsTPProIfInfoIfIndex + Unsigned32, + sleMplsTPProIfInfoIpAddr + IpAddress + } + + sleMplsTPProIfInfoIfIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object is used in accommodating the bigger + size Global_Node_ID and/or ICC with lower size LSR + identifier in order to index the mplsTunnelTable. + + The Local Identifier is configured between 1 and 16777215, + as valid IP address range starts from 16777216(01.00.00.00). + This range is chosen to identify the mplsTunnelTable's + Ingress/Egress LSR-id is IP address or Local identifier, + if the configured range is not IP address, administrator is + expected to retrieve the complete information + (Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable. + This way, existing mplsTunnelTable is reused for + bidirectional tunnel extensions for MPLS based transport networks. + + This Local Identifier allows the administrator to assign + a unique identifier to map Global_Node_ID and/or ICC." + ::= { sleMplsTpProIfInfoEntry 1 } + + + sleMplsTPProIfInfoIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION " " + ::= { sleMplsTpProIfInfoEntry 2 } + + + sleMplsTpProIfControl OBJECT IDENTIFIER ::= { sleMplsTpProIf 2 } + + + sleMplsTpProIfControlRequest OBJECT-TYPE + SYNTAX INTEGER + { + setMplsTpProIfIpAddr(1), + unSetMplsTpProIfIpAddr(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object holds the possible read-write columns that + can be modified in the TunnelExtNodeConfigTable table. + For each read-write column of TunnelExtNodeConfigTable table, + a Set Operation control value is added in this object." + ::= { sleMplsTpProIfControl 1 } + + + sleMplsTpProIfControlStatus OBJECT-TYPE + SYNTAX SleControlStatusType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object displays the status of the configuration done." + ::= { sleMplsTpProIfControl 2 } + + + sleMplsTpProIfControlTimer OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is based on the SLE style where a timer is configured for every control table." + ::= { sleMplsTpProIfControl 3 } + + + sleMplsTpProIfControlTimestamp OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the time at which the configuration is done." + ::= { sleMplsTpProIfControl 4 } + + + sleMplsTpProIfControlReqResult OBJECT-TYPE + SYNTAX SleControlRequestResultType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The standard result of the SET operation is stored here." + ::= { sleMplsTpProIfControl 5 } + + + sleMplsTpProIfControlIfIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION " " + ::= { sleMplsTpProIfControl 6 } + + + sleMplsTpProIfControlIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object indicates the Global Operator Identifier." + REFERENCE + "MPLS-TP Identifiers [RFC6370]." + ::= { sleMplsTpProIfControl 7 } + + + + END + +-- +-- sle-mpls-tp-pro-if-mib.mib +-- -- cgit v1.2.3