From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/comware/HH3C-STACK-MIB | 640 ++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 640 insertions(+) create mode 100644 MIBS/comware/HH3C-STACK-MIB (limited to 'MIBS/comware/HH3C-STACK-MIB') diff --git a/MIBS/comware/HH3C-STACK-MIB b/MIBS/comware/HH3C-STACK-MIB new file mode 100644 index 0000000..1b74abc --- /dev/null +++ b/MIBS/comware/HH3C-STACK-MIB @@ -0,0 +1,640 @@ +-- ================================================================= +-- Copyright (c) 2004-2021 New H3C Tech. Co., Ltd. All rights reserved +-- +-- Description: stack mib +-- Reference: STACK-MIB +-- Version: V1.5 +-- History: +-- V1.0 Created by ranbin +-- Initial version 2008-04-30 +-- V1.1 2012-02-24 Modified by zhengwei +-- Changed the range of link delay to 0 to 30000 ms +-- V1.2 2013-08-16 Updated by wangpengju +-- Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable +-- 2013-10-23 Updated by zhengwei +-- Added notification nodes because MAD group work status changed: +-- hh3cStackMadBfdChangeNormal +-- hh3cStackMadBfdChangeFailure +-- hh3cStackMadLacpChangeNormal +-- hh3cStackMadLacpChangeFailure +-- V1.3 2014-08-11 Updated by SongHao +-- Added hh3cStackDomainId +-- 2014-11-20 Updated by songhao +-- Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig. +-- hh3cStackLinkDelayInterval was changed to in the range of 0 to 2147483647 ms +-- V1.4 2020-03-03 Updated by zhangwenbo +-- Added notification node hh3cStackPhysicalIntfLinkUp +-- Added notification node hh3cStackPhysicalIntfLinkDown +-- Added hh3cStackPhysicalIntfName +-- V1.5 2021-03-17 Updated by meishenhe +-- Added notification node hh3cStackPhysicalIntfRxTimeout +-- ================================================================= +HH3C-STACK-MIB DEFINITIONS ::= BEGIN + +IMPORTS + hh3cCommon + FROM HH3C-OID-MIB + entPhysicalIndex + FROM ENTITY-MIB + ifIndex, ifDescr + FROM IF-MIB + Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32 + FROM SNMPv2-SMI; + +hh3cStack MODULE-IDENTITY + LAST-UPDATED "202103250943Z" + ORGANIZATION + "New H3C Technologies Co., Ltd." + CONTACT-INFO + "Platform Team New H3C Technologies Co., Ltd. + Hai-Dian District Beijing P.R. China + Http://www.h3c.com + Zip:100085" + DESCRIPTION + "This MIB is used to manage STM (Stack Topology Management) + information for IRF (Intelligent Resilient Framework) device. + This MIB is applicable to IRF-capable products. Some objects in + this MIB may be used only for some specific products, so users should + refer to the related documents to acquire more detailed information." + REVISION "202103250943Z" + DESCRIPTION + "Added notification node hh3cStackPhysicalIntfRxTimeout." + REVISION "201411200850Z" + DESCRIPTION + "Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig. + hh3cStackLinkDelayInterval was changed to in the range of 0 to + 2147483647 ms." + REVISION "201408110641Z" + DESCRIPTION + "Added hh3cStackDomainId." + REVISION "201310230000Z" + DESCRIPTION + "Added notification nodes because MAD group work status changed: + hh3cStackMadBfdChangeNormal + hh3cStackMadBfdChangeFailure + hh3cStackMadLacpChangeNormal + hh3cStackMadLacpChangeFailure" + REVISION "201308160000Z" + DESCRIPTION + "Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable." + REVISION "201202240000Z" + DESCRIPTION + "Changed the range of link delay to 0 to 30000 ms." + REVISION "200804301650Z" -- 30th April, 2007 at 16:50 GMT + DESCRIPTION + "The initial revision of this MIB module." + ::= { hh3cCommon 91 } + + +-- Scalar MIB objects, which are considered as global variables +-- Global Level Configuration + +hh3cStackGlobalConfig OBJECT IDENTIFIER ::= { hh3cStack 1 } + +hh3cStackMaxMember OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of members in a stack." + ::= { hh3cStackGlobalConfig 1 } + +hh3cStackMemberNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of members currently in a stack." + ::= { hh3cStackGlobalConfig 2 } + +hh3cStackMaxConfigPriority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The highest priority that can be configured for a member in a stack." + ::= { hh3cStackGlobalConfig 3 } + +hh3cStackAutoUpdate OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + enabled(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The function for automatically updating the image from the master to + a device that is attempting to join the stack. + When a new device tries to join a stack, STM verifies the image + consistency between the joining device and the master. + If the joining device uses a different image version than the master, + the function updates the joining device with the image of the master. + When this function is disabled, the new device can't join the stack + if it uses a different software version than the master. + + disabled: disable auto update function + enabled: enable auto update function" + ::= { hh3cStackGlobalConfig 4 } + +hh3cStackMacPersistence OBJECT-TYPE + SYNTAX INTEGER + { + notPersist(1), + persistForSixMin(2), + persistForever(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The mode of bridge MAC address persistence. When a stack starts, + the bridge MAC address of the master is used as that of the stack. + When the master leaves the stack, the bridge MAC address of the + stack changes depending on the mode of bridge MAC address persistence. + + notPersist: The bridge MAC address of the new master is used + as that of the stack immediately. + persistForSixMin: The original bridge MAC address will be reserved for six + minutes. In this period, if the master that has left rejoins the stack, + the bridge MAC address of the stack will not change. + If the old master doesn't rejoin the stack within this period, the + bridge MAC address of the new master will be used as that of the stack. + persistForever: Whether the master leaves or not, the bridge MAC address + of the stack will never change." + ::= { hh3cStackGlobalConfig 5 } + +hh3cStackLinkDelayInterval OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + UNITS "millisecond" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Delay for stack ports to report a link down event. If the link comes up + before the delay timer expires, the stack port will not report the link + down event. If the link is not recovered before the delay timer expires, + the stack port will report the change. If the delay is set to 0, + the stack ports will report a link down event without delay. + + 0: no delay + other value(ms): delay time" + ::= { hh3cStackGlobalConfig 6 } + +hh3cStackTopology OBJECT-TYPE + SYNTAX INTEGER + { + chainConn(1), + ringConn(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Stack topology. + + chainConn: daisy-chain connection + ringConn: ring connection" + ::= { hh3cStackGlobalConfig 7 } + +hh3cStackDomainId OBJECT-TYPE + SYNTAX Unsigned32 (0..4294967295) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Domain ID of the IRF fabric that is used to uniquely identify an IRF fabric. + Domain IDs prevent IRF fabrics from interfering with one another." + ::= { hh3cStackGlobalConfig 8 } + +hh3cStackPortConfigActivate OBJECT-TYPE + SYNTAX INTEGER + { + none(1), + set(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "After connecting the physical interfaces between two devices and + binding them to the correct IRF ports, you must + activate the settings on the IRF ports. This operation merges the two + devices into one IRF fabric. The system activates the IRF port + settings automatically in the following situations: + 1. The configuration file that the device starts with contains + IRF port bindings. + 2. You are binding physical interfaces to an IRF port after an IRF fabric + is formed. + + none: If the user sets this object to none, this object will return + a success without performing any operation. + + set: Activates the settings on the IRF ports. + After the settings is activated, this object will return to + none at the next reading." + DEFVAL { none } + ::= { hh3cStackGlobalConfig 9 } + +-- Device Level Configuration +hh3cStackDeviceConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cStackDeviceConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage device information in a stack." + ::= { hh3cStack 2 } + +hh3cStackDeviceConfigEntry OBJECT-TYPE + SYNTAX Hh3cStackDeviceConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage device information in a stack." + INDEX + { + entPhysicalIndex + } + ::= { hh3cStackDeviceConfigTable 1 } + +Hh3cStackDeviceConfigEntry ::= SEQUENCE + { + hh3cStackMemberID Integer32, + hh3cStackConfigMemberID Integer32, + hh3cStackPriority Integer32, + hh3cStackPortNum Integer32, + hh3cStackPortMaxNum Integer32 + } + +hh3cStackMemberID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The member ID of the device in a stack." + ::= { hh3cStackDeviceConfigEntry 1 } + +hh3cStackConfigMemberID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The configured member ID of the device. The valid value ranges from + 1 to the value in hh3cStackMaxMember. The configured member ID will + take effect at a reboot if it is unique within the stack." + ::= { hh3cStackDeviceConfigEntry 2 } + +hh3cStackPriority OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The priority of a device in the stack. The valid value ranges from + 1 to the value in hh3cStackMaxConfigPriority." + ::= { hh3cStackDeviceConfigEntry 3 } + +hh3cStackPortNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of stack ports enabled on a device." + ::= { hh3cStackDeviceConfigEntry 4 } + +hh3cStackPortMaxNum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of stack ports on a device." + ::= { hh3cStackDeviceConfigEntry 5 } + + +-- Board Level Configuration +hh3cStackBoardConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cStackBoardConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage MPU information for a stack." + ::= { hh3cStack 3 } + +hh3cStackBoardConfigEntry OBJECT-TYPE + SYNTAX Hh3cStackBoardConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage MPU information for a stack." + INDEX + { + entPhysicalIndex + } + ::= { hh3cStackBoardConfigTable 1 } + +Hh3cStackBoardConfigEntry ::= SEQUENCE + { + hh3cStackBoardRole INTEGER, + hh3cStackBoardBelongtoMember Integer32 + } + +hh3cStackBoardRole OBJECT-TYPE + SYNTAX INTEGER + { + slave(1), + master(2), + loading(3), + other(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The role of the MPU in a stack. + + slave: Standby MPU + master: Master MPU + loading: Standby MPU is loading the software image from the master. + other: other" + ::= { hh3cStackBoardConfigEntry 1 } + +hh3cStackBoardBelongtoMember OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Member ID of the device that holds the current board." + ::= { hh3cStackBoardConfigEntry 2 } + + +-- stack port Information +hh3cStackPortInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cStackPortInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage stack port information + for IRF stacked devices." + ::= { hh3cStack 4 } + +hh3cStackPortInfoEntry OBJECT-TYPE + SYNTAX Hh3cStackPortInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage stack port information + for IRF stacked devices." + INDEX + { + hh3cStackMemberID, + hh3cStackPortIndex + } + ::= { hh3cStackPortInfoTable 1 } + +Hh3cStackPortInfoEntry ::= SEQUENCE + { + hh3cStackPortIndex Integer32, + hh3cStackPortEnable INTEGER, + hh3cStackPortStatus INTEGER, + hh3cStackNeighbor Integer32, + hh3cStackPortForwardingPath OCTET STRING + } + +hh3cStackPortIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The index of a stack port of the device." + ::= { hh3cStackPortInfoEntry 1 } + +hh3cStackPortEnable OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + enabled(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The status of a stack port of the device. If no physical + interfaces are added to the stack port, its status is disabled. + If the stack port has physical interfaces, its status is enabled. + + disabled: The stack port is disabled. + enabled: The stack port is enabled." + ::= { hh3cStackPortInfoEntry 2 } + +hh3cStackPortStatus OBJECT-TYPE + SYNTAX INTEGER + { + up(1), + down(2), + silent(3), + disabled(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The link status of a stack port on the device. + + up: A physical link is present on the stack port. + down: No physical link is present on the stack port. + silent: The link state of the stack port is up, + but the port can't transmit or receive traffic. + disabled: The stack port doesn't contain physical links." + ::= { hh3cStackPortInfoEntry 3 } + +hh3cStackNeighbor OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The member ID of the stack port's neighbor. 0 means no + neighbor exists." + ::= { hh3cStackPortInfoEntry 4 } + +hh3cStackPortForwardingPath OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..511)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "List of egress member IDs on a stack port. + Each member device uses the egress member ID lists to choose the outgoing + stack port for known unicast frames to be sent out of other member devices. + The egress member ID lists are comma separated. + A zero-length string means no egress members exist. + + For example: + In a ring stack of 1-2-3-4-5-7-1, + if hh3cStackPortForwardingPath.1.1 returns '7,5,4', + IRF-port 1/1 will be the outgoing port for frames to reach members 7, 5, + and 4 from member 1." + ::= { hh3cStackPortInfoEntry 5 } + +-- Physical interface Information +hh3cStackPhyPortInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF Hh3cStackPhyPortInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage information about physical + interfaces that can be used for IRF stacking." + ::= { hh3cStack 5 } + +hh3cStackPhyPortInfoEntry OBJECT-TYPE + SYNTAX Hh3cStackPhyPortInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects to manage information about physical + interfaces that can be used for IRF stacking." + INDEX + { + entPhysicalIndex + } + ::= { hh3cStackPhyPortInfoTable 1 } + +Hh3cStackPhyPortInfoEntry ::= SEQUENCE + { + hh3cStackBelongtoPort Integer32 + } + +hh3cStackBelongtoPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The index of the stack port to which the physical interface is added. + 0 means the physical interface is not added to any stack port. + The value will take effect when IRF is enabled on the device." + ::= { hh3cStackPhyPortInfoEntry 1 } + +-- +-- Notification definitions +-- +-- ================================================================= +-- Traps are defined below. +hh3cStackTrap OBJECT IDENTIFIER ::= { hh3cStack 6 } + +hh3cStackTrapOjbects OBJECT IDENTIFIER ::= { hh3cStackTrap 0 } +-- All trap definitions should be placed under this object. + +hh3cStackPortLinkStatusChange NOTIFICATION-TYPE + OBJECTS + { + hh3cStackMemberID, + hh3cStackPortIndex, + hh3cStackPortStatus + } + + STATUS current + DESCRIPTION + "The hh3cStackPortLinkStatusChange trap indicates that the link status + of the stack port has changed." + ::= { hh3cStackTrapOjbects 1 } + +hh3cStackTopologyChange NOTIFICATION-TYPE + OBJECTS + { + hh3cStackTopology + } + STATUS current + DESCRIPTION + "The hh3cStackTopologyChange trap indicates that the topology type of + the IRF stack has changed." + ::= { hh3cStackTrapOjbects 2 } + +hh3cStackMadBfdChangeNormal NOTIFICATION-TYPE + OBJECTS + { + ifIndex, + ifDescr + } + STATUS current + DESCRIPTION + "The hh3cStackMadBfdChangeNormal trap indicates that the BFD MAD function + changed to the normal state." + ::= { hh3cStackTrapOjbects 3 } + +hh3cStackMadBfdChangeFailure NOTIFICATION-TYPE + OBJECTS + { + ifIndex, + ifDescr + } + STATUS current + DESCRIPTION + "The hh3cStackMadBfdChangeFailure trap indicates that the BFD MAD function + changed to the failure state." + ::= { hh3cStackTrapOjbects 4 } + +hh3cStackMadLacpChangeNormal NOTIFICATION-TYPE + OBJECTS + { + ifIndex, + ifDescr + } + STATUS current + DESCRIPTION + "The hh3cStackMadLacpChangeNormal trap indicates that the LACP MAD function + changed to the normal state." + ::= { hh3cStackTrapOjbects 5 } + +hh3cStackMadLacpChangeFailure NOTIFICATION-TYPE + OBJECTS + { + ifIndex, + ifDescr + } + STATUS current + DESCRIPTION + "The hh3cStackMadLacpChangeFailure trap indicates that the LACP MAD function + changed to the failure state." + ::= { hh3cStackTrapOjbects 6 } + +hh3cStackPhysicalIntfLinkUp NOTIFICATION-TYPE + OBJECTS + { + hh3cStackMemberID, + hh3cStackPortIndex, + hh3cStackPhysicalIntfName + } + STATUS current + DESCRIPTION + "The hh3cStackPhysicalIntfLinkUp trap indicates that the status + of the stack physical interface has changed to the up state." + ::= { hh3cStackTrapOjbects 7 } + +hh3cStackPhysicalIntfLinkDown NOTIFICATION-TYPE + OBJECTS + { + hh3cStackMemberID, + hh3cStackPortIndex, + hh3cStackPhysicalIntfName + } + STATUS current + DESCRIPTION + "The hh3cStackPhysicalIntfLinkDown trap indicates that the status + of the stack physical interface has changed to the down state." + ::= { hh3cStackTrapOjbects 8 } + +hh3cStackPhysicalIntfRxTimeout NOTIFICATION-TYPE + OBJECTS + { + hh3cStackMemberID, + hh3cStackPortIndex, + hh3cStackPhysicalIntfName + } + STATUS current + DESCRIPTION + "The hh3cStackPhysicalIntfRxTimeout trap indicates that the timer for the stack + physical interface to receive packets has timed out." + ::= { hh3cStackTrapOjbects 9 } + +hh3cStackTrapObjectDefinitions OBJECT IDENTIFIER ::= { hh3cStackTrap 1 } +-- All objects used for TRAP only are defined here. + +hh3cStackPhysicalIntfName OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..255)) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The textual name of the stack physical interface." + ::= { hh3cStackTrapObjectDefinitions 1 } + +END + -- cgit v1.2.3