From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/calix/OCCAM-MLT-MIB | 1681 ++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 1681 insertions(+) create mode 100644 MIBS/calix/OCCAM-MLT-MIB (limited to 'MIBS/calix/OCCAM-MLT-MIB') diff --git a/MIBS/calix/OCCAM-MLT-MIB b/MIBS/calix/OCCAM-MLT-MIB new file mode 100644 index 0000000..4d418df --- /dev/null +++ b/MIBS/calix/OCCAM-MLT-MIB @@ -0,0 +1,1681 @@ + +OCCAM-MLT-MIB DEFINITIONS ::= BEGIN + IMPORTS + occamGenericMonitorModules + FROM OCCAM-REG-MODULE + TEXTUAL-CONVENTION + FROM SNMPv2-TC + MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, + Integer32, NOTIFICATION-TYPE + FROM SNMPv2-SMI; + + occamMltMib MODULE-IDENTITY + LAST-UPDATED "200104271051Z" + ORGANIZATION "Occam Networks" + CONTACT-INFO "email support@occamnetworks.com" + DESCRIPTION + "This mib module describes objects used + to perform Metallic Line Testing on customer + access lines and to provide results." + + REVISION "200104271051Z" + DESCRIPTION "Reformatted certain text" + + REVISION "200704170000Z" + DESCRIPTION "replace kOhm with Ohm in DC resistance + UNITS" + + REVISION "200702220000Z" + DESCRIPTION "remove DISPLAY-HINT" + + REVISION "200609261000Z" + DESCRIPTION "Removed Gr909 from fuse test result names" + + REVISION "200602220135Z" + DESCRIPTION "Initial version." + ::= { occamGenericMonitorModules 3 } + +-- TEXTUAL-CONVENTIONS -- + + MltTestType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A selection value for requesting or forcing + a test. A requested test will only run if the + port is not in use. A forced test will + immediately shut the port and run the test." + SYNTAX INTEGER { request ( 1 ) , + force ( 2 ) } + + MltTestStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An indication of test status: + none = no test has been requested. + mltbusy = another port is currently being tested. + complete = the last requested test has completed. + portInUse = the last requested port is in use, + the test was not run. Rerunning the test as + 'forced' will shut the port and run the test. + inProgress = the last requested test is still + running. mltError = the mlt program reported an + error and aborted the test.Check the mltErrorText + object. + mltNotResponding = the mlt program didn't return + a result." + SYNTAX INTEGER { + none ( 1 ) , + mltBusy ( 2 ), + complete ( 3 ) , + portInUse ( 4 ) , + inProgress ( 5 ), + mltError ( 6 ), + mltNotResponding ( 7 ) } + + MltTestIdentifier ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An mlt test selection value." + SYNTAX INTEGER { + statusSuite ( 1 ) , + mltSuite ( 2 ) , + activeModeVoltages ( 3 ) , + highImpedanceModeVoltages ( 4 ) , + dcResistance ( 5 ) , + capacitance ( 6 ) , + loopDetect ( 7 ) , + loopLength ( 8 ) } + + MltTestHookState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An mlt test hook state value." + SYNTAX INTEGER { + onhook ( 1 ) , + offhook ( 2 ), + notAvailable ( 3 ) } + + MltTestPassFail ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An mlt test pass/fail value." + SYNTAX INTEGER { + pass ( 1 ) , + fail ( 2 ), + notAvailable ( 3 ) } + + MltTestRingerResult ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An mlt ringer test result value." + SYNTAX INTEGER { + pass ( 1 ) , + fail ( 2 ), + notAvailable ( 3 ), + low ( 4 ) } + + MltTestYesNo ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An mlt test pass/fail value." + SYNTAX INTEGER { + yes ( 1 ) , + no ( 2 ), + notAvailable ( 3 ) } + +-- The Metallic Loop Test Configuration group + + mltTestConfig OBJECT IDENTIFIER + ::= { occamMltMib 1 } + + +-- The Metallic Loop Test Status group + + mltTestStatus OBJECT IDENTIFIER + ::= { occamMltMib 2 } + + +-- The Metallic Loop Test Results group + + mltTestResults OBJECT IDENTIFIER + ::= { occamMltMib 3 } + +-- The Metallic Loop Test Notifications group + + mltTestNotifications OBJECT IDENTIFIER + ::= { occamMltMib 4 } + + +-- Objects of the MLT Configuration group + + mltTestIdentifier OBJECT-TYPE + SYNTAX MltTestIdentifier + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the mlt test to be run. + Setting this value starts a test. + + This is a required parameter. + + Approximate expected test durations are as + follows: + + statusSuite 1 second + mltSuite 1 minute + activeModeVoltages 3 seconds + highImpedanceModeVoltages 9 seconds + dcResistance 18 seconds + capacitance 18 seconds + loopDetect 9 seconds + loopLength 9 seconds." + ::= { mltTestConfig 1 } + + mltTestType OBJECT-TYPE + SYNTAX MltTestType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects if a test is requested (only run if port + is not in use) or forced. + This is an optional parameter. If not specified, + the request option is used." + ::= { mltTestConfig 2 } + + mltTestPort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 48 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects voice channel on which test will be run. + This is a required parameter." + ::= { mltTestConfig 3 } + + mltDcResistanceRange OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 3 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects DC Resistance range value. + This is an optional paramater. Default is 0 + (auto mode)." + ::= { mltTestConfig 4 } + + mltLoopLengthMultiplier OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 200 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects loop length multiplier in nf. This is an + optional parameter. If not specified an internal + default value of 83nF/mile is used." + ::= { mltTestConfig 5 } + + mltLoopDetectThreshold OBJECT-TYPE + SYNTAX Integer32 ( 5 .. 200 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the detection threshold in nF. + This is an optional parameter. If not supplied, + a loop detection threshold of 10nF is used." + ::= { mltTestConfig 6 } + + +-- Objects of the MLT Test Status group + + mltLastTestStatus OBJECT-TYPE + SYNTAX MltTestStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the status of the last run mlt test. + Given that the various mlt tests take several + seconds to 1 1/2 minutes to run, it is suggested + that status polls be spaced 10-20 seconds apart. + Additionally, a monitoring application could + wait for the testComplete notification." + ::= { mltTestStatus 1 } + + mltErrorText OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the textual error in the case of an + aborted test." + ::= { mltTestStatus 2 } + + +-- Objects of the MLT Test Results group + +-- mlt status results table + mltStatusResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltStatusResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the status test + suite." + ::= { mltTestResults 1 } + + mltStatusResultsEntry OBJECT-TYPE + SYNTAX MltStatusResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of status suite tests. + + Note that a numerical result value of -999 means + that there was an error of some sort and the + value could not be measured." + INDEX { mltTestPort } + ::= { mltStatusResultsTable 1 } + + MltStatusResultsEntry ::= SEQUENCE { + mltStatusAlarm OCTET STRING, + mltStatusHookState MltTestHookState, + mltStatusTransversalCurrent Integer32, + mltStatusLongitudinalCurrent Integer32, + mltStatusTipVoltage Integer32, + mltStatusRingVoltage Integer32, + mltStatusTipRingVoltage Integer32, + mltStatusVdd Integer32 + } + + + mltStatusAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when + status test was run." + ::= { mltStatusResultsEntry 1 } + + + mltStatusHookState OBJECT-TYPE + SYNTAX MltTestHookState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates line hook state when status test was + run." + ::= { mltStatusResultsEntry 2 } + + + mltStatusTransversalCurrent OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates transversal current when status test + was run." + ::= { mltStatusResultsEntry 3 } + + + mltStatusLongitudinalCurrent OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates Longitudinal current when status test + was run." + ::= { mltStatusResultsEntry 4 } + + + mltStatusTipVoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates tip voltage when status test was run." + ::= { mltStatusResultsEntry 5 } + + + mltStatusRingVoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates ring voltage when status test was run." + ::= { mltStatusResultsEntry 6 } + + mltStatusTipRingVoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates tip-ring voltage when status test was + run." + ::= { mltStatusResultsEntry 7 } + + + mltStatusVdd OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates Vdd when status test was run." + ::= { mltStatusResultsEntry 8 } + +-- mlt test results table + mltTestResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltTestResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the mlt test suite. + Note that a numerical result value of -999 means + that there was an error of some sort and the + value could not be measured. + Also, a resistance value of 9999 means that the + result was greater than 1000 kOhms, but the exact + value could not be measured." + ::= { mltTestResults 2 } + + mltTestResultsEntry OBJECT-TYPE + SYNTAX MltTestResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt suite tests." + INDEX { mltTestPort } + ::= { mltTestResultsTable 1 } + + MltTestResultsEntry ::= SEQUENCE { + mltTestAlarm OCTET STRING, + mltTestHookState MltTestHookState, + mltTestVdd Integer32, + mltTestActiveModeVoltagesVdctr Integer32, + mltTestActiveModeVoltagesVdctg Integer32, + mltTestActiveModeVoltagesVdcrg Integer32, + mltTestActiveModeVoltagesVactr Integer32, + mltTestActiveModeVoltagesVactg Integer32, + mltTestActiveModeVoltagesVacrg Integer32, + mltTestHighImpedanceModeVoltagesVdctr Integer32, + mltTestHighImpedanceModeVoltagesVdctg Integer32, + mltTestHighImpedanceModeVoltagesVdcrg Integer32, + mltTestHighImpedanceModeVoltagesVactr Integer32, + mltTestHighImpedanceModeVoltagesVactg Integer32, + mltTestHighImpedanceModeVoltagesVacrg Integer32, + mltTestDcCurrentsItransversal Integer32, + mltTestDcCurrentsIlongitudinal Integer32, + mltTestDcCurrentsItip Integer32, + mltTestDcCurrentsIring Integer32, + mltTestCapacitanceCeqtr Integer32, + mltTestCapacitanceCeqtg Integer32, + mltTestCapacitanceCeqrg Integer32, + mltTestResistanceRtr Integer32, + mltTestResistanceRtg Integer32, + mltTestResistanceRrg Integer32, + mltTestGr909HazardousPotentialTestResult MltTestPassFail, + mltTestGr909ForeignEmfTestResult MltTestPassFail, + mltTestGr909FuseTestTipFuse MltTestPassFail, + mltTestGr909FuseTestRingFuse MltTestPassFail, + mltTestFuseTestTipFuse MltTestPassFail, + mltTestFuseTestRingFuse MltTestPassFail, + mltTestGr909ResistiveFaultTestResult MltTestPassFail, + mltTestGr909ReceiverOffhookTestResult MltTestPassFail, + mltTestGr909ReceiverOffhookTestResistance1 Integer32, + mltTestGr909ReceiverOffhookTestResistance2 Integer32, + mltTestGr909ReceiverOffhookTestDifference Integer32, + mltTestGr909RingerTestResult MltTestRingerResult, + mltTestGr909RingerTestRen Integer32, + mltTestErrors OCTET STRING + } + + + mltTestAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "GNK and OTEMP bits set by the DuSLIC will be + reported as alarms. GNK is typically cause by + ground fault or foreign voltage condition. + OTEMP is set when the DuSLIC is experiencing + thermal overload. This parameter is + non-intrusive." + ::= { mltTestResultsEntry 1 } + + mltTestHookState OBJECT-TYPE + SYNTAX MltTestHookState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hook state reflects the DuSLIC hook bit + (offhook/onhook). This parameter is + non-intrusive." + ::= { mltTestResultsEntry 2 } + + mltTestVdd OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "On HDPOTS, internal Voltage VDD will be + reported and compared to statistically derived + thresholds. + This parameter is intrusive during offhook but + will be available during onhook." + ::= { mltTestResultsEntry 3 } + + mltTestActiveModeVoltagesVdctr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring + in a normal no shutdown state. AC voltages for + T-R, T-G and R-G will be reported. + Active mode measurements will not be available + when alarm is detected. This parameter is + intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 4 } + + mltTestActiveModeVoltagesVdctg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring + in a normal no shutdown state. AC voltages for + T-R, T-G and R-G will be reported. + Active mode measurements will not be available + when alarm is detected. This parameter is + intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 5 } + + mltTestActiveModeVoltagesVdcrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring + in a normal no shutdown state. AC voltages for + T-R, T-G and R-G will be reported. + Active mode measurements will not be available + when alarm is detected. This parameter is + intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 6 } + + mltTestActiveModeVoltagesVactr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring + in a normal no shutdown state. Thus, VT and VR + measurements should be 0 volt. + AC voltages for T-R, T-G and R-G will be + reported. Active mode measurements will not be + available when alarm is detected. This parameter + is intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 7 } + + mltTestActiveModeVoltagesVactg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring + in a normal no shutdown state. Thus, VT and VR + measurements should be 0 volt. AC voltages for T-R, T-G + and R-G will be reported. Active mode measurements will + not be available when alarm is detected. This parameter + is intrusive and will be available in shutdown state + only." + ::= { mltTestResultsEntry 8 } + + mltTestActiveModeVoltagesVacrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. Thus, VT and VR measurements + should be 0 volt. AC voltages for T-R, T-G and R-G will + be reported. Active mode measurements will not be + available when alarm is detected. This parameter is + intrusive and will be available in shutdown state only." + + ::= { mltTestResultsEntry 9 } + + mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 10 } + + mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 11 } + + mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 12 } + + mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): In this mode, the DuSLIC tip and ring are in + high impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 13 } + + mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 14 } + + mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 15 } + + mltTestDcCurrentsItransversal OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Four DC currents will be reported: IT, IL, It and Ir. + In normal condition, currents will be measured in + active mode. These measurements will not be available if + alarm is present." + ::= { mltTestResultsEntry 16 } + + mltTestDcCurrentsIlongitudinal OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Four DC currents will be reported: IT, IL, It and Ir. + In normal condition, currents will be measured in active + mode. These measurements will not be available if alarm + is present." + ::= { mltTestResultsEntry 17 } + + mltTestDcCurrentsItip OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Four DC currents will be reported: IT, IL, It and Ir. + In normal condition, currents will be measured in active + mode. These measurements will not be available if alarm + is present." + ::= { mltTestResultsEntry 18 } + + mltTestDcCurrentsIring OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Four DC currents will be reported: IT, IL, It and Ir. + In normal condition, currents will be measured in active + mode. These measurements will not be available if alarm + is present." + ::= { mltTestResultsEntry 19 } + + mltTestCapacitanceCeqtr OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) circuit. In the presence of a + network of capacitance (figure 3), the individual + capacitance will not be resolved. The equivalent + capacitances CEQtr, CEQtg and CEQrg will be reported. + They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltTestResultsEntry 20 } + + mltTestCapacitanceCeqtg OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) + circuit. In the presence of a network of capacitance + (figure 3), the + individual capacitance will not be resolved. The + equivalent capacitances CEQtr, CEQtg and CEQrg will be + reported. They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltTestResultsEntry 21 } + + mltTestCapacitanceCeqrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) circuit. In the presence of a + network of capacitance (figure 3), the individual + capacitance will not be resolved. The equivalent + capacitances CEQtr, CEQtg and CEQrg will be reported. + They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltTestResultsEntry 22 } + + mltTestResistanceRtr OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying 3 + resistance ranges: (1) low, (2) medium, (3) high. If not + specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state ` + only." + ::= { mltTestResultsEntry 23 } + + mltTestResistanceRtg OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying + 3 resistance ranges: (1) low, (2) medium, (3) high. If + not specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state + only." + ::= { mltTestResultsEntry 24 } + + mltTestResistanceRrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying + 3 resistance ranges: (1) low, (2) medium, (3) high. If + not specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state + only." + ::= { mltTestResultsEntry 25 } + + mltTestGr909HazardousPotentialTestResult OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if the T-G or R-G ac voltage is greater + than 50 volts rms or the T-G or R-G dc voltage is + greater than 135 volts. This test will report pass/fail. + This test is intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 26 } + + mltTestGr909ForeignEmfTestResult OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if the T-G or R-G ac voltage is greater + than 50 volts rms or the T-G or R-G dc voltage is + greater than 135 volts. This test will report pass/fail. + This test is intrusive and will be available in shutdown + state only." + ::= { mltTestResultsEntry 27 } + + mltTestGr909FuseTestTipFuse OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "This test determines if these fuses are blown. This + test will return pass/fail for tip and ring. This test + will not be performed if alarm is present. This + parameter is intrusive. This test is intrusive and will + be available in shutdown state only. + + This object is obsolete. Object name was changed." + ::= { mltTestResultsEntry 28 } + + mltTestGr909FuseTestRingFuse OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "This test determines if these fuses are blown. This + test will return pass/fail for tip and ring. This test + will not be performed if alarm is present. This + parameter is intrusive. This test is intrusive and will + be available in shutdown state only. + + This object is obsolete. Object name was changed." + ::= { mltTestResultsEntry 29 } + + mltTestFuseTestTipFuse OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test determines if these fuses are blown. This + test will return pass/fail for tip and ring. This test + will not be performed if alarm is present. This + parameter is intrusive. This test is intrusive and will + be available in shutdown state only." + ::= { mltTestResultsEntry 38 } + + mltTestFuseTestRingFuse OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test determines if these fuses are blown. This + test will return pass/fail for tip and ring. This test + will not be performed if alarm is present. This + parameter is intrusive. This test is intrusive and will + be available in shutdown state only." + ::= { mltTestResultsEntry 39 } + + mltTestGr909ResistiveFaultTestResult OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if the T-R, T-G or R-G dc resistance is + less than 150k ohm. This test will not be performed if + fuse test fails or alarm is present. This test will + return pass/fail. This test is intrusive and will be + available in shutdown state only." + ::= { mltTestResultsEntry 30 } + + mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE + SYNTAX MltTestPassFail + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if a non-linearity in the T-R dc + resistance of greater than 15% when measured at two + different voltage levels exists. This test will not be + performed if fuse test fails or alarm is present. This + test will return the DC resistances at two different + operating points and the percent difference between the + two DC resistances. This test is intrusive and will be + available in shutdown state only. " + ::= { mltTestResultsEntry 31 } + + mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if a non-linearity in the T-R dc + resistance of greater than 15% when measured at two + different voltage levels exists. This test will not be + performed if fuse test fails or alarm is present. This + test will return the DC resistances at two different + operating points and the percent difference between the + two DC resistances. This test is intrusive and will be + available in shutdown state only. " + ::= { mltTestResultsEntry 32 } + + mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if a non-linearity in the T-R dc + resistance of greater than 15% when measured at two + different voltage levels exists. This test will not be + performed if fuse test fails or alarm is present. This + test will return the DC resistances at two different + operating points and the percent difference between the + two DC resistances. This test is intrusive and will be + available in shutdown state only. " + ::= { mltTestResultsEntry 33 } + + mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE + SYNTAX Integer32 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails if a non-linearity in the T-R dc + resistance of greater than 15% when measured at two + different voltage levels exists. This test will not be + performed if fuse test fails or alarm is present. This + test will return the DC resistances at two different + operating points and the percent difference between the + two DC resistances. This test is intrusive and will be + available in shutdown state only. " + ::= { mltTestResultsEntry 34 } + + mltTestGr909RingerTestResult OBJECT-TYPE + SYNTAX MltTestRingerResult + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails when the equivalent ringer count across + tip and ring is less than 0.175 REN or greater than 5 + REN. This test will not run if fuse test fails or alarm + is present. This test will report passed/fail and the + REN number. This parameter is intrusive and will be + available in shutdown state shutdown only." + ::= { mltTestResultsEntry 35 } + + mltTestGr909RingerTestRen OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 REN" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This test fails when the equivalent ringer count across + tip and ring is less than 0.175 REN or greater than 5 + REN. This test will not run if fuse test fails or alarm + is present. This test will report passed/fail and the + REN number. This parameter is intrusive and will be + available in shutdown state shutdown only." + ::= { mltTestResultsEntry 36 } + + mltTestErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltTestResultsEntry 37 } + +-- mlt active mode voltages results table + mltActiveModeVoltagesResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides results of the mlt active mode + voltages test. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could not + be measured." + ::= { mltTestResults 3 } + + mltActiveModeVoltagesResultsEntry OBJECT-TYPE + SYNTAX MltActiveModeVoltagesResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt active mode voltages test." + INDEX { mltTestPort } + ::= { mltActiveModeVoltagesResultsTable 1 } + + MltActiveModeVoltagesResultsEntry ::= SEQUENCE { + mltActiveModeVoltagesVdctr Integer32, + mltActiveModeVoltagesVdctg Integer32, + mltActiveModeVoltagesVdcrg Integer32, + mltActiveModeVoltagesVactr Integer32, + mltActiveModeVoltagesVactg Integer32, + mltActiveModeVoltagesVacrg Integer32, + mltActiveModeVoltagesErrors OCTET STRING + } + + mltActiveModeVoltagesVdctr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. AC voltages for T-R, T-G and + R-G will be reported. + Active mode measurements will not be available when + alarm is detected. This parameter is intrusive and will + be available in shutdown state only." + ::= { mltActiveModeVoltagesResultsEntry 1 } + + mltActiveModeVoltagesVdctg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. AC voltages for T-R, T-G and + R-G will be reported. Active mode measurements will not + be available when alarm is detected. This parameter is + intrusive and will be available in shutdown state only." + ::= { mltActiveModeVoltagesResultsEntry 2 } + + mltActiveModeVoltagesVdcrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. AC voltages for T-R, T-G and + R-G will be reported. Active mode measurements will not + be available when alarm is detected. This parameter is + intrusive and will be available in shutdown state only." + ::= { mltActiveModeVoltagesResultsEntry 3 } + + mltActiveModeVoltagesVactr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. Thus, VT and VR measurements + should be 0 volt. AC voltages for T-R, T-G and R-G will + be reported. Active mode measurements will not be + available when alarm is detected. This parameter is + intrusive and will be available in shutdown state only." + ::= { mltActiveModeVoltagesResultsEntry 4 } + + mltActiveModeVoltagesVactg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. Thus, VT and VR measurements + should be 0 volt. AC voltages for T-R, T-G and R-G will + be reported. Active mode measurements will not be + available when alarm is detected. This parameter is + intrusive and will be available in shutdown state only." + ::= { mltActiveModeVoltagesResultsEntry 5 } + + mltActiveModeVoltagesVacrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Active Mode Tip/Ring AC Voltages: + In active mode, the DuSLIC drives the tip/ring in a + normal no shutdown state. Thus, VT and VR measurements + should be 0 volt. AC voltages for T-R, T-G and R-G will + be reported. + Active mode measurements will not be available when + alarm is detected. This parameter is intrusive and will + be available in shutdown state only." + + ::= { mltActiveModeVoltagesResultsEntry 6 } + + mltActiveModeVoltagesErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltActiveModeVoltagesResultsEntry 7 } + +-- mlt high impedance mode voltages results table + mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF +MltHighImpedanceModeVoltagesResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the mlt test suite. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could not + be measured." + ::= { mltTestResults 4 } + + mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE + SYNTAX MltHighImpedanceModeVoltagesResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt high impedance mode voltages test." + INDEX { mltTestPort } + ::= { mltHighImpedanceModeVoltagesResultsTable 1 } + + MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE { + mltHighImpedanceModeVoltagesVdctr Integer32, + mltHighImpedanceModeVoltagesVdctg Integer32, + mltHighImpedanceModeVoltagesVdcrg Integer32, + mltHighImpedanceModeVoltagesVactr Integer32, + mltHighImpedanceModeVoltagesVactg Integer32, + mltHighImpedanceModeVoltagesVacrg Integer32, + mltHighImpedanceModeVoltagesErrors OCTET STRING + } + + mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 1 } + + mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 2 } + + mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vdc" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring DC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. DC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 3 } + + mltHighImpedanceModeVoltagesVactr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 4 } + + mltHighImpedanceModeVoltagesVactg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 5 } + + mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Vrms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Impedance Mode Tip/Ring AC Voltages (Foreign + Voltages): + In this mode, the DuSLIC tip and ring are in high + impedance. The measured voltages represent foreign + voltages. AC voltages for T-R, T-G and R-G will be + reported. This parameter is intrusive and will be + available in shutdown state only." + ::= { mltHighImpedanceModeVoltagesResultsEntry 6 } + + mltHighImpedanceModeVoltagesErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltHighImpedanceModeVoltagesResultsEntry 7 } + +-- mlt DC resistance results table + mltDcResistanceResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltDcResistanceResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the DC resistance test. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could not + be measured. Also, a resistance value of 9999 means + that the result was greater than 1000 kOhms, but the + exact value could not be measured." + ::= { mltTestResults 5 } + + mltDcResistanceResultsEntry OBJECT-TYPE + SYNTAX MltDcResistanceResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt DC resistance test." + INDEX { mltTestPort } + ::= { mltDcResistanceResultsTable 1 } + + MltDcResistanceResultsEntry ::= SEQUENCE { + mltDcResistanceRtr Integer32, + mltDcResistanceRtg Integer32, + mltDcResistanceRrg Integer32, + mltDcResistanceErrors OCTET STRING + } + + + mltDcResistanceRtr OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying + 3 resistance ranges: (1) low, (2) medium, (3) high. If + not specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state + only." + ::= { mltDcResistanceResultsEntry 1 } + + mltDcResistanceRtg OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying + 3 resistance ranges: (1) low, (2) medium, (3) high. If + not specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state + only." + ::= { mltDcResistanceResultsEntry 2 } + + mltDcResistanceRrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "Ohm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DC resistance measurements will be based on a 3 + terminal circuit model. Rtr, Rtg and Rrg will be + provided. User will have the option of specifying + 3 resistance ranges: (1) low, (2) medium, (3) high. If + not specified, auto mode will be used. Resistance + measurements will not be available if fuse test fails or + alarm is present. This parameter is intrusive. This test + is intrusive and will be available in shutdown state + only." + ::= { mltDcResistanceResultsEntry 3 } + + mltDcResistanceErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltDcResistanceResultsEntry 4 } + +-- mlt capacitance results table + mltCapacitanceResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltCapacitanceResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the mlt test suite. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could not + be measured." + ::= { mltTestResults 6 } + + mltCapacitanceResultsEntry OBJECT-TYPE + SYNTAX MltCapacitanceResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt capacitance test." + INDEX { mltTestPort } + ::= { mltCapacitanceResultsTable 1 } + + MltCapacitanceResultsEntry ::= SEQUENCE { + mltCapacitanceCeqtr Integer32, + mltCapacitanceCeqtg Integer32, + mltCapacitanceCeqrg Integer32, + mltCapacitanceErrors OCTET STRING + } + + mltCapacitanceCeqtr OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) circuit. In the presence of a + network of capacitance (figure 3), the individual + capacitance will not be resolved. The equivalent + capacitances CEQtr, CEQtg and CEQrg will be reported. + They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltCapacitanceResultsEntry 1 } + + mltCapacitanceCeqtg OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) circuit. In the presence of a + network of capacitance (figure 3), the individual + capacitance will not be resolved. The equivalent + capacitances CEQtr, CEQtg and CEQrg will be reported. + They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltCapacitanceResultsEntry 2 } + + mltCapacitanceCeqrg OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Capacitance measurements will support only single + element (2 terminal) circuit. In the presence of a + network of capacitance (figure 3), the individual + capacitance will not be resolved. The equivalent + capacitances CEQtr, CEQtg and CEQrg will be reported. + They represent the following: + + CEQtr = Ctr + Ctg/4 + Crg/4 + CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) + CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) + + Capacitance measurements will not be available if fuse + test fails or alarm is present. This test is intrusive + and will be available in shutdown state only." + ::= { mltCapacitanceResultsEntry 3 } + + mltCapacitanceErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltCapacitanceResultsEntry 4 } + +-- mlt loop detect results table + mltLoopDetectResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltLoopDetectResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the mlt loop detect test. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could not + be measured." + ::= { mltTestResults 7 } + + mltLoopDetectResultsEntry OBJECT-TYPE + SYNTAX MltLoopDetectResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt loop detect test." + INDEX { mltTestPort } + ::= { mltLoopDetectResultsTable 1 } + + MltLoopDetectResultsEntry ::= SEQUENCE { + mltLoopDetectLoopCapacitance Integer32, + mltLoopDetectDetectionThreshold Integer32, + mltLoopDetectLoopDetected MltTestYesNo, + mltLoopDetectErrors OCTET STRING + } + + mltLoopDetectLoopCapacitance OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop detection will be based on tip-ring capacitance + measurement. User will be able to specify the detection + threshold. If not supplied,loop detection threshold of + 10 nF will be used. This test will not be available if + fuse test fails or alarm is present. This test is + intrusive and will be available in shutdown state only." + ::= { mltLoopDetectResultsEntry 1 } + + mltLoopDetectDetectionThreshold OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop detection will be based on tip-ring capacitance + measurement. User will be able to specify the detection + threshold. If not supplied, loop detection threshold of + 10 nF will be used. This test will not be available if + fuse test fails or alarm is present. This test is + intrusive and will be available in shutdown state only." + ::= { mltLoopDetectResultsEntry 2 } + + mltLoopDetectLoopDetected OBJECT-TYPE + SYNTAX MltTestYesNo + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop detection will be based on tip-ring capacitance + measurement. User will be able to specify the detection + threshold. If not supplied, loop detection threshold + of 10 nF will be used. This test will not be available + if fuse test fails or alarm is present. This test is + intrusive and will be available in shutdown state only." + ::= { mltLoopDetectResultsEntry 3 } + + mltLoopDetectErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test + was run." + ::= { mltLoopDetectResultsEntry 4 } + +-- mlt loop length results table + mltLoopLengthResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MltLoopLengthResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides result of the mlt loop length test. + Note that a numerical result value of -999 means that + there was an error of some sort and the value could + not be measured." + ::= { mltTestResults 8 } + + mltLoopLengthResultsEntry OBJECT-TYPE + SYNTAX MltLoopLengthResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry holding information about results + of mlt loop length test." + INDEX { mltTestPort } + ::= { mltLoopLengthResultsTable 1 } + + MltLoopLengthResultsEntry ::= SEQUENCE { + mltLoopLengthCapacitanceFactor Integer32, + mltLoopLengthLoopCapacitance Integer32, + mltLoopLengthLoopLength Integer32, + mltLoopLengthUncompensatedLoopCapacitance Integer32, + mltLoopLengthUncompensatedLoopLength Integer32, + mltLoopLengthErrors OCTET STRING + } + + mltLoopLengthCapacitanceFactor OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF/mile" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop length estimate will be based on tip-ring + capacitance measurement. User will be able to + specify the loop length multiplier. If not supplied, + loop length multiplier of 83 nF/ mile will be used. + This test will not be available if fuse test fails + or alarm is present. This test is intrusive and will + be available in shutdown state only." + ::= { mltLoopLengthResultsEntry 1 } + + mltLoopLengthLoopCapacitance OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop length estimate will be based on tip-ring + capacitance measurement. User will be able to specify + the loop length multiplier. If not supplied, loop length + multiplier of 83 nF/ mile will be used. This test will + not be available if fuse test fails or alarm is present. + This test is intrusive and will be available in shutdown + state only. " + ::= { mltLoopLengthResultsEntry 2 } + + mltLoopLengthLoopLength OBJECT-TYPE + SYNTAX Integer32 + UNITS "ft" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop length estimate will be based on tip-ring + capacitance measurement. User will be able to specify + the loop length multiplier. If not supplied, loop length + multiplier of 83 nF/ mile will be used. This test will + not be available if fuse test fails or alarm is present. + This test is intrusive and will be available in shutdown + state only. " + ::= { mltLoopLengthResultsEntry 3 } + + mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE + SYNTAX Integer32 + UNITS "nF" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop length estimate will be based on tip-ring + capacitance measurement. User will be able to specify + the loop length multiplier. If not supplied, loop length + multiplier of 83 nF/ mile will be used. This test will + not be available if fuse test fails or alarm is present. + This test is intrusive and will be available in shutdown + state only. This value has no DSL correction." + ::= { mltLoopLengthResultsEntry 4 } + + mltLoopLengthUncompensatedLoopLength OBJECT-TYPE + SYNTAX Integer32 + UNITS "ft" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Loop length estimate will be based on tip-ring + capacitance measurement. User will be able to specify + the loop length multiplier. If not supplied, loop length + multiplier of 83 nF/ mile will be used. This test will + not be available if fuse test fails or alarm is present. + This test is intrusive and will be available in shutdown + state only. This value has no DSL correction." + ::= { mltLoopLengthResultsEntry 5 } + + + mltLoopLengthErrors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates GNK and/or OTEMP alarms active when test was + run." + ::= { mltLoopLengthResultsEntry 6 } + +-- notifications + + mltTestCompletedNotification NOTIFICATION-TYPE + OBJECTS { mltTestIdentifier, mltTestPort, + mltLastTestStatus, mltErrorText } + STATUS current + DESCRIPTION + "This notification is sent to the + requesting host when the requested mlt + test has completed." + ::= { mltTestNotifications 1 } + + + +END -- cgit v1.2.3