From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB | 661 +++++++++++++++++++++++++++++++ 1 file changed, 661 insertions(+) create mode 100644 MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB (limited to 'MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB') diff --git a/MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB b/MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB new file mode 100644 index 0000000..90152de --- /dev/null +++ b/MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB @@ -0,0 +1,661 @@ +-- ============================================================================ +-- AT-PLUGGABLE-DIAGNOSTICS-MIB, Allied Telesis enterprise MIB: +-- Diagnostic objects related to Optical Pluggable modules. +-- +-- Copyright (c) 2015 by Allied Telesis, Inc. +-- All rights reserved. +-- +-- ============================================================================ + +AT-PLUGGABLE-DIAGNOSTICS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + DisplayStringUnsized + FROM AT-SMI-MIB + sysinfo + FROM AT-SYSINFO-MIB + Integer32, OBJECT-TYPE, MODULE-IDENTITY + FROM SNMPv2-SMI + InterfaceIndex + FROM IF-MIB; + + +atPluggableDiag MODULE-IDENTITY + LAST-UPDATED "201507170000Z" + ORGANIZATION "Allied Telesis, Inc" + CONTACT-INFO "http://www.alliedtelesis.com" + DESCRIPTION + "The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard + diagnostic information from installed SFP modules." + REVISION "201507170000Z" + DESCRIPTION "Initial revision" + ::= { sysinfo 28 } + +---------------------------------------------------------------- +-- The Digital Diagnostic monitoring for optical pluggables +---------------------------------------------------------------- + +atPluggableDiagTable OBJECT IDENTIFIER ::= { atPluggableDiag 1 } + +---------------------------------------------------------------- +-- Temperature table for Digital Diagnostic monitoring +---------------------------------------------------------------- + +atPluggableDiagTempTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagTempEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the various temperature parameters observed + as a part of Digital diagnostics monitoring, for all the optical pluggables + installed in the devices." + ::= { atPluggableDiagTable 1 } + +atPluggableDiagTempEntry OBJECT-TYPE + SYNTAX AtPluggableDiagTempEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various temperature parameters of pluggables + such as current status reading, current alarm status, higher and lower + alarm threshold, current warning, higher and lower warning threshold." + INDEX { atPluggableDiagTempIfIndex, atPluggableDiagTempChannel } + ::= { atPluggableDiagTempTable 1 } + +AtPluggableDiagTempEntry ::= SEQUENCE { + atPluggableDiagTempIfIndex InterfaceIndex, + atPluggableDiagTempChannel Integer32, + atPluggableDiagTempStatusReading Integer32, + atPluggableDiagTempCurrentAlarm OCTET STRING, + atPluggableDiagTempAlarmMax Integer32, + atPluggableDiagTempAlarmMin Integer32, + atPluggableDiagTempCurrentWarning OCTET STRING, + atPluggableDiagTempWarningMax Integer32, + atPluggableDiagTempWarningMin Integer32 } + +atPluggableDiagTempIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagTempEntry 1 } + +atPluggableDiagTempChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagTempEntry 2 } + +atPluggableDiagTempStatusReading OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 degree C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current temperature status reading." + ::= { atPluggableDiagTempEntry 3 } + +atPluggableDiagTempCurrentAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current temperature alarm reading." + ::= { atPluggableDiagTempEntry 4 } + +atPluggableDiagTempAlarmMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 degree C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum temperature alarm threshold value." + ::= { atPluggableDiagTempEntry 5 } + +atPluggableDiagTempAlarmMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 degree C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum temperature alarm threshold value." + ::= { atPluggableDiagTempEntry 6 } + +atPluggableDiagTempCurrentWarning OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current temperature warnings." + ::= { atPluggableDiagTempEntry 7 } + +atPluggableDiagTempWarningMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 degree C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum temperature warning threshold value." + ::= { atPluggableDiagTempEntry 8 } + +atPluggableDiagTempWarningMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 degree C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum temperature warning threshold value." + ::= { atPluggableDiagTempEntry 9 } + +---------------------------------------------------------------- +-- Voltage (Vcc) table for Digital Diagnostic monitoring +---------------------------------------------------------------- + +atPluggableDiagVccTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagVccEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the various Voltage (Vcc) parameters observed + as a part of Digital diagnostics monitoring, for all the optical pluggables + installed in the devices." + ::= { atPluggableDiagTable 2 } + +atPluggableDiagVccEntry OBJECT-TYPE + SYNTAX AtPluggableDiagVccEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various Voltage (Vcc) parameters of pluggables + such as current status reading, current alarm status, higher and lower + alarm threshold, current warning, higher and lower warning threshold." + INDEX { atPluggableDiagVccIfIndex, atPluggableDiagVccChannel } + ::= { atPluggableDiagVccTable 1 } + +AtPluggableDiagVccEntry ::= SEQUENCE { + atPluggableDiagVccIfIndex InterfaceIndex, + atPluggableDiagVccChannel Integer32, + atPluggableDiagVccStatusReading Integer32, + atPluggableDiagVccCurrentAlarm OCTET STRING, + atPluggableDiagVccAlarmMax Integer32, + atPluggableDiagVccAlarmMin Integer32, + atPluggableDiagVccCurrentWarning OCTET STRING, + atPluggableDiagVccWarningMax Integer32, + atPluggableDiagVccWarningMin Integer32 } + +atPluggableDiagVccIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagVccEntry 1 } + +atPluggableDiagVccChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagVccEntry 2 } + +atPluggableDiagVccStatusReading OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Voltage (Vcc) status reading." + ::= { atPluggableDiagVccEntry 3 } + +atPluggableDiagVccCurrentAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Voltage (Vcc) alarm reading." + ::= { atPluggableDiagVccEntry 4 } + +atPluggableDiagVccAlarmMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Voltage (Vcc) alarm threshold value." + ::= { atPluggableDiagVccEntry 5 } + +atPluggableDiagVccAlarmMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Voltage (Vcc) alarm threshold value." + ::= { atPluggableDiagVccEntry 6 } + +atPluggableDiagVccCurrentWarning OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Voltage (Vcc) warnings." + ::= { atPluggableDiagVccEntry 7 } + +atPluggableDiagVccWarningMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Voltage (Vcc) warning threshold value." + ::= { atPluggableDiagVccEntry 8 } + +atPluggableDiagVccWarningMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Voltage (Vcc) warning threshold value." + ::= { atPluggableDiagVccEntry 9 } + +---------------------------------------------------------------- +-- Tx Bias Current (mA) table for Digital Diagnostic monitoring +---------------------------------------------------------------- + +atPluggableDiagTxBiasTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagTxBiasEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the various Tx Bias Current (mA) + parameters observed as a part of Digital diagnostics monitoring, + for all the optical pluggables installed in the devices." + ::= { atPluggableDiagTable 3 } + +atPluggableDiagTxBiasEntry OBJECT-TYPE + SYNTAX AtPluggableDiagTxBiasEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various Tx Bias Current (mA) + parameters of pluggables such as current status reading, + current alarm status, higher and lower alarm threshold, + current warning, higher and lower warning threshold." + INDEX { atPluggableDiagTxBiasIfIndex, atPluggableDiagTxBiasChannel } + ::= { atPluggableDiagTxBiasTable 1 } + +AtPluggableDiagTxBiasEntry ::= SEQUENCE { + atPluggableDiagTxBiasIfIndex InterfaceIndex, + atPluggableDiagTxBiasChannel Integer32, + atPluggableDiagTxBiasStatusReading Integer32, + atPluggableDiagTxBiasCurrentAlarm OCTET STRING, + atPluggableDiagTxBiasAlarmMax Integer32, + atPluggableDiagTxBiasAlarmMin Integer32, + atPluggableDiagTxBiasCurrentWarning OCTET STRING, + atPluggableDiagTxBiasWarningMax Integer32, + atPluggableDiagTxBiasWarningMin Integer32 } + +atPluggableDiagTxBiasIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagTxBiasEntry 1 } + +atPluggableDiagTxBiasChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagTxBiasEntry 2 } + +atPluggableDiagTxBiasStatusReading OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Bias (mA) status reading." + ::= { atPluggableDiagTxBiasEntry 3 } + +atPluggableDiagTxBiasCurrentAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Bias (mA) alarm reading." + ::= { atPluggableDiagTxBiasEntry 4 } + +atPluggableDiagTxBiasAlarmMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Tx Bias (mA) alarm threshold value." + ::= { atPluggableDiagTxBiasEntry 5 } + +atPluggableDiagTxBiasAlarmMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Tx Bias (mA) alarm threshold value." + ::= { atPluggableDiagTxBiasEntry 6 } + +atPluggableDiagTxBiasCurrentWarning OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Bias (mA) warnings." + ::= { atPluggableDiagTxBiasEntry 7 } + +atPluggableDiagTxBiasWarningMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Tx Bias (mA) warning threshold value." + ::= { atPluggableDiagTxBiasEntry 8 } + +atPluggableDiagTxBiasWarningMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Tx Bias (mA) warning threshold value." + ::= { atPluggableDiagTxBiasEntry 9 } + +---------------------------------------------------------------- +-- Tx Power (mW) table for Digital Diagnostic monitoring +---------------------------------------------------------------- + +atPluggableDiagTxPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagTxPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the various Tx Power (mW) + parameters observed as a part of Digital diagnostics monitoring, + for all the optical pluggables installed in the devices." + ::= { atPluggableDiagTable 4 } + +atPluggableDiagTxPowerEntry OBJECT-TYPE + SYNTAX AtPluggableDiagTxPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various Tx Power (mW) + parameters of pluggables such as current status reading, + current alarm status, higher and lower alarm threshold, + current warning, higher and lower warning threshold." + INDEX { atPluggableDiagTxPowerIfIndex, atPluggableDiagTxPowerChannel } + ::= { atPluggableDiagTxPowerTable 1 } + +AtPluggableDiagTxPowerEntry ::= SEQUENCE { + atPluggableDiagTxPowerIfIndex InterfaceIndex, + atPluggableDiagTxPowerChannel Integer32, + atPluggableDiagTxPowerStatusReading Integer32, + atPluggableDiagTxPowerCurrentAlarm OCTET STRING, + atPluggableDiagTxPowerAlarmMax Integer32, + atPluggableDiagTxPowerAlarmMin Integer32, + atPluggableDiagTxPowerCurrentWarning OCTET STRING, + atPluggableDiagTxPowerWarningMax Integer32, + atPluggableDiagTxPowerWarningMin Integer32 } + +atPluggableDiagTxPowerIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagTxPowerEntry 1 } + +atPluggableDiagTxPowerChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagTxPowerEntry 2 } + +atPluggableDiagTxPowerStatusReading OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Power (mW) status reading." + ::= { atPluggableDiagTxPowerEntry 3 } + +atPluggableDiagTxPowerCurrentAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Power (mW) alarm reading." + ::= { atPluggableDiagTxPowerEntry 4 } + +atPluggableDiagTxPowerAlarmMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Tx Power (mW) alarm threshold value." + ::= { atPluggableDiagTxPowerEntry 5 } + +atPluggableDiagTxPowerAlarmMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Tx Power (mW) alarm threshold value." + ::= { atPluggableDiagTxPowerEntry 6 } + +atPluggableDiagTxPowerCurrentWarning OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx Power (mW) warnings." + ::= { atPluggableDiagTxPowerEntry 7 } + +atPluggableDiagTxPowerWarningMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Tx Power (mW) warning threshold value." + ::= { atPluggableDiagTxPowerEntry 8 } + +atPluggableDiagTxPowerWarningMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Tx Power (mW) warning threshold value." + ::= { atPluggableDiagTxPowerEntry 9 } + +---------------------------------------------------------------- +-- Rx Power (mW) table for Digital Diagnostic monitoring +---------------------------------------------------------------- + +atPluggableDiagRxPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagRxPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the various Rx Power (mW) + parameters observed as a part of Digital diagnostics monitoring, + for all the optical pluggables installed in the devices." + ::= { atPluggableDiagTable 5 } + +atPluggableDiagRxPowerEntry OBJECT-TYPE + SYNTAX AtPluggableDiagRxPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various Rx Power (mW) + parameters of pluggables such as current status reading, + current alarm status, higher and lower alarm threshold, + current warning, higher and lower warning threshold." + INDEX { atPluggableDiagRxPowerIfIndex, atPluggableDiagRxPowerChannel } + ::= { atPluggableDiagRxPowerTable 1 } + +AtPluggableDiagRxPowerEntry ::= SEQUENCE { + atPluggableDiagRxPowerIfIndex InterfaceIndex, + atPluggableDiagRxPowerChannel Integer32, + atPluggableDiagRxPowerStatusReading Integer32, + atPluggableDiagRxPowerCurrentAlarm OCTET STRING, + atPluggableDiagRxPowerAlarmMax Integer32, + atPluggableDiagRxPowerAlarmMin Integer32, + atPluggableDiagRxPowerCurrentWarning OCTET STRING, + atPluggableDiagRxPowerWarningMax Integer32, + atPluggableDiagRxPowerWarningMin Integer32 } + +atPluggableDiagRxPowerIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagRxPowerEntry 1 } + +atPluggableDiagRxPowerChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagRxPowerEntry 2 } + +atPluggableDiagRxPowerStatusReading OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Rx Power (mW) status reading." + ::= { atPluggableDiagRxPowerEntry 3 } + +atPluggableDiagRxPowerCurrentAlarm OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Rx Power (mW) alarm reading." + ::= { atPluggableDiagRxPowerEntry 4 } + +atPluggableDiagRxPowerAlarmMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Rx Power (mW) alarm threshold value." + ::= { atPluggableDiagRxPowerEntry 5 } + +atPluggableDiagRxPowerAlarmMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Rx Power (mW) alarm threshold value." + ::= { atPluggableDiagRxPowerEntry 6 } + +atPluggableDiagRxPowerCurrentWarning OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Rx Power (mW) warnings." + ::= { atPluggableDiagRxPowerEntry 7 } + +atPluggableDiagRxPowerWarningMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum Rx Power (mW) warning threshold value." + ::= { atPluggableDiagRxPowerEntry 8 } + +atPluggableDiagRxPowerWarningMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.0001 mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum Rx Power (mW) warning threshold value." + ::= { atPluggableDiagRxPowerEntry 9 } + +----------------------------------------------------------------------- +-- Rx Loss of Signal (LOS) table for Digital Diagnostic monitoring +----------------------------------------------------------------------- + +atPluggableDiagRxLosTable OBJECT-TYPE + SYNTAX SEQUENCE OF AtPluggableDiagRxLosEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information regarding the Rx Loss of Singal (Los) + parameters observed as a part of Digital diagnostics monitoring, + for all the optical pluggables installed in the devices." + ::= { atPluggableDiagTable 6 } + +atPluggableDiagRxLosEntry OBJECT-TYPE + SYNTAX AtPluggableDiagRxLosEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The information about various Rx Loss of Singal (Los) parameters + of pluggables such as current status reading." + INDEX { atPluggableDiagRxLosIfIndex, atPluggableDiagRxLosChannel } + ::= { atPluggableDiagRxLosTable 1 } + +AtPluggableDiagRxLosEntry ::= SEQUENCE { + atPluggableDiagRxLosIfIndex InterfaceIndex, + atPluggableDiagRxLosChannel Integer32, + atPluggableDiagRxLosStatusReading OCTET STRING } + +atPluggableDiagRxLosIfIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifindex of the pluggable." + ::= { atPluggableDiagRxLosEntry 1 } + +atPluggableDiagRxLosChannel OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The channel number of the pluggable." + ::= { atPluggableDiagRxLosEntry 2 } + +atPluggableDiagRxLosStatusReading OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Rx Los status reading." + ::= { atPluggableDiagRxLosEntry 3 } + +END -- cgit v1.2.3