From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/audiocodes/AC-SS7-MIB | 4794 ++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 4794 insertions(+) create mode 100644 MIBS/audiocodes/AC-SS7-MIB (limited to 'MIBS/audiocodes/AC-SS7-MIB') diff --git a/MIBS/audiocodes/AC-SS7-MIB b/MIBS/audiocodes/AC-SS7-MIB new file mode 100644 index 0000000..3f580b4 --- /dev/null +++ b/MIBS/audiocodes/AC-SS7-MIB @@ -0,0 +1,4794 @@ + +AC-SS7-MIB DEFINITIONS ::= BEGIN + + + IMPORTS + + + OBJECT-TYPE, + MODULE-IDENTITY FROM SNMPv2-SMI + TAddress, + DisplayString, + DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC + IpAddress FROM RFC1155-SMI + Unsigned32, + Integer32, + enterprises FROM SNMPv2-SMI + RowStatus FROM SNMPv2-TC + SnmpAdminString FROM SNMP-FRAMEWORK-MIB + InetAddressType, InetAddress FROM INET-ADDRESS-MIB + MODULE-COMPLIANCE, OBJECT-GROUP, + NOTIFICATION-GROUP FROM SNMPv2-CONF + audioCodes, + acRegistrations, + acGeneric, + acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB; + + +acSS7 MODULE-IDENTITY + LAST-UPDATED "201207260528Z" --Thursday, July 26 2012 + ORGANIZATION "AudioCodes Ltd" + CONTACT-INFO + "Postal: Support + AudioCodes LTD + 1 Hayarden Street + Airport City + Lod, ISRAEL 70151 + Tel: 972-3-9764000 + Fax: 972-3-9764040 + Email: support@audiocodes.com + Web: www.audiocodes.com" + + DESCRIPTION + "" + + + + ::= {acBoardMibs 12} + + + + + + + + + acSS7Configuration OBJECT IDENTIFIER ::= {acSS7 1} + + + acSS7MTP2 OBJECT IDENTIFIER ::= {acSS7Configuration 1} + + + acSS7MTP2M3bSlDiscardCongThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter concerns feature that prevents uncontrolled increase +of the MTP2 Transmit queue when the upper levels ignores +the usual flow control mechanism. +Any new SL_TX_MSU_RQ is discarded when the number of msu queued +on the TB or RTB overtakes the threshold. +Value 0, means that this feature is not activated. +Access: Offline. +AC INI-Param: SS7M3bSlDiscardCongThreshold" + ::= {acSS7MTP2 1} + + + + -- **************************************** + -- acSS7MTP2Attrib table declaration + -- **************************************** + acSS7MTP2AttribTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7MTP2AttribEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7MTP2 21} + + + + -- **************************************** + -- acSS7MTP2Attrib table entry + -- **************************************** + acSS7MTP2AttribEntry OBJECT-TYPE + SYNTAX AcSS7MTP2AttribEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7MTP2AttribIndex} + ::= {acSS7MTP2AttribTable 1} + + + + -- **************************************** + -- acSS7MTP2Attrib TABLE + -- **************************************** + AcSS7MTP2AttribEntry ::= SEQUENCE { + acSS7MTP2AttribIndex Unsigned32, + acSS7MTP2AttribIsUsed INTEGER, + acSS7MTP2AttribLinkRate SnmpAdminString, + acSS7MTP2AttribErrorCorectionMethod SnmpAdminString, + acSS7MTP2AttribIacCp Unsigned32, + acSS7MTP2AttribSUERMThreshold Unsigned32, + acSS7MTP2AttribAERMNormalThreshold Unsigned32, + acSS7MTP2AttribAERMEmerglThreshold Unsigned32, + acSS7MTP2AttribSUERMSigUnitDThreshold Unsigned32, + acSS7MTP2AttribOctetCounting Unsigned32, + acSS7MTP2AttribTimerT1 Unsigned32, + acSS7MTP2AttribTimerT2 Unsigned32, + acSS7MTP2AttribTimerT3 Unsigned32, + acSS7MTP2AttribTimerT4Normal Unsigned32, + acSS7MTP2AttribTimerT4Emerg Unsigned32, + acSS7MTP2AttribTimerT5 Unsigned32, + acSS7MTP2AttribTimerT6 Unsigned32, + acSS7MTP2AttribTimerT7 Unsigned32, + acSS7MTP2AttribLSSULength Unsigned32, + acSS7MTP2AttribPcrN2 Unsigned32, + acSS7MTP2AttribRowStatus RowStatus + } + + + + acSS7MTP2AttribIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..3) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index Field for line. +AC INI-Param: SS7Mtp2Parms_Index" + ::= {acSS7MTP2AttribEntry 1} + + + + acSS7MTP2AttribIsUsed OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the row used by alink. +If it is the entrow will be read. +AC INI-Param: N/A" + ::= {acSS7MTP2AttribEntry 2} + + + + acSS7MTP2AttribLinkRate OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..1)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 SLI Link Rate. +Choose either: +A = 64 kbps +D = 56 kbps +0 = 64 kbps. +Access: Online. +AC INI-Param: SS7Mtp2Parms_LinkRate" + ::= {acSS7MTP2AttribEntry 3} + + + + acSS7MTP2AttribErrorCorectionMethod OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..1)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SLI error correction method. +B = Basic +P = PCR (Preventive Cyclic Retransmission). +Access: Online. +AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod" + ::= {acSS7MTP2AttribEntry 4} + + + + acSS7MTP2AttribIacCp OBJECT-TYPE + SYNTAX Unsigned32 (0..10) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the number of aborted proving attempts before sending +an out-of-service to MTP-3. +Access: Online. +AC INI-Param: SS7Mtp2Parms_IacCp" + ::= {acSS7MTP2AttribEntry 5} + + + + acSS7MTP2AttribSUERMThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..256) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold. +Access: Online. +AC INI-Param: SS7Mtp2Parms_SuermT" + ::= {acSS7MTP2AttribEntry 6} + + + + acSS7MTP2AttribAERMNormalThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..20) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Normal AERM (alignment error rate monitor) threshold [0 to 20]. +Access: Online. +AC INI-Param: SS7Mtp2Parms_AermTin" + ::= {acSS7MTP2AttribEntry 7} + + + + acSS7MTP2AttribAERMEmerglThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..10) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Emergency AERM (alignment error rate monitor) threshold [0 to +10]. +Access: Online. +AC INI-Param: SS7Mtp2Parms_AermTie" + ::= {acSS7MTP2AttribEntry 8} + + + + acSS7MTP2AttribSUERMSigUnitDThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..256) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 Signal Unit error rate monitor D threshold. +Access: Online. +AC INI-Param: SS7Mtp2Parms_SuermSuD" + ::= {acSS7MTP2AttribEntry 9} + + + + acSS7MTP2AttribOctetCounting OBJECT-TYPE + SYNTAX Unsigned32 (0..256) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 Octet received while the OCTET is in counting +mode (# of Octets received - N Octets - while in Octet +counting mode). +Access: Online. +AC INI-Param: SS7Mtp2Parms_OctetCounting" + ::= {acSS7MTP2AttribEntry 10} + + + + acSS7MTP2AttribTimerT1 OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 T1 alignment ready timer (in msecs). +Access: Online. +AC INI-Param: SS7Mtp2Parms_T1" + ::= {acSS7MTP2AttribEntry 11} + + + + acSS7MTP2AttribTimerT2 OBJECT-TYPE + SYNTAX Unsigned32 (0..200000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 T2 unaligned timer (in msecs). +Access: Online. +AC INI-Param: SS7Mtp2Parms_T2" + ::= {acSS7MTP2AttribEntry 12} + + + + acSS7MTP2AttribTimerT3 OBJECT-TYPE + SYNTAX Unsigned32 (0..20000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 T3 timer aligned. +Access: Online. +AC INI-Param: SS7Mtp2Parms_T3" + ::= {acSS7MTP2AttribEntry 13} + + + + acSS7MTP2AttribTimerT4Normal OBJECT-TYPE + SYNTAX Unsigned32 (0..15000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 T4n Normal proving period timer. +Access: Online. +AC INI-Param: SS7Mtp2Parms_T4n" + ::= {acSS7MTP2AttribEntry 14} + + + + acSS7MTP2AttribTimerT4Emerg OBJECT-TYPE + SYNTAX Unsigned32 (0..5000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 T4e Emergency proving period timer (msec). +Access: Online. +AC INI-Param: SS7Mtp2Parms_T4e" + ::= {acSS7MTP2AttribEntry 15} + + + + acSS7MTP2AttribTimerT5 OBJECT-TYPE + SYNTAX Unsigned32 (0..2400) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 Sending SIB timer. +Access: Online. +AC INI-Param: SS7Mtp2Parms_T5" + ::= {acSS7MTP2AttribEntry 16} + + + + acSS7MTP2AttribTimerT6 OBJECT-TYPE + SYNTAX Unsigned32 (0..10000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 Remote Congestion timer (in msec). +Access: Online. +AC INI-Param: SS7Mtp2Parms_T6" + ::= {acSS7MTP2AttribEntry 17} + + + + acSS7MTP2AttribTimerT7 OBJECT-TYPE + SYNTAX Unsigned32 (0..5000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 excessive delay of the ack timer (in msec). +Access: Online. +AC INI-Param: SS7Mtp2Parms_T7" + ::= {acSS7MTP2AttribEntry 18} + + + + acSS7MTP2AttribLSSULength OBJECT-TYPE + SYNTAX Unsigned32 (1..2) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes). +Access: Online. +AC INI-Param: SS7Mtp2Parms_LssuLength" + ::= {acSS7MTP2AttribEntry 19} + + + + acSS7MTP2AttribPcrN2 OBJECT-TYPE + SYNTAX Unsigned32 (0..512) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to define Preventive Cyclic Retransmission +- the number of message signal unit octets available for +retransmission (ITU-T Q703 6.4 - Forced retransmission). +Access: Online. +AC INI-Param: SS7Mtp2Parms_PcrN2" + ::= {acSS7MTP2AttribEntry 20} + + + + acSS7MTP2AttribRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: N/A" + ::= {acSS7MTP2AttribEntry 21} + + + + acSS7Timers OBJECT IDENTIFIER ::= {acSS7Configuration 2} + + + -- **************************************** + -- acSS7SignalingNodeTimers table declaration + -- **************************************** + acSS7SignalingNodeTimersTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7SignalingNodeTimersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Timers 21} + + + + -- **************************************** + -- acSS7SignalingNodeTimers table entry + -- **************************************** + acSS7SignalingNodeTimersEntry OBJECT-TYPE + SYNTAX AcSS7SignalingNodeTimersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7SignalingNodeTimersIndex} + ::= {acSS7SignalingNodeTimersTable 1} + + + + -- **************************************** + -- acSS7SignalingNodeTimers TABLE + -- **************************************** + AcSS7SignalingNodeTimersEntry ::= SEQUENCE { + acSS7SignalingNodeTimersIndex Unsigned32, + acSS7SignalingNodeTimersIsUsed INTEGER, + acSS7SignalingNodeTimersAction INTEGER, + acSS7SignalingNodeTimersActionResult INTEGER, + acSS7SignalingNodeTimersName SnmpAdminString, + acSS7SignalingNodeTimersT6 Unsigned32, + acSS7SignalingNodeTimersT8 Unsigned32, + acSS7SignalingNodeTimersT10 Unsigned32, + acSS7SignalingNodeTimersT11 Unsigned32, + acSS7SignalingNodeTimersT15 Unsigned32, + acSS7SignalingNodeTimersT16 Unsigned32, + acSS7SignalingNodeTimersT18ITU Unsigned32, + acSS7SignalingNodeTimersT19ITU Unsigned32, + acSS7SignalingNodeTimersT20ITU Unsigned32, + acSS7SignalingNodeTimersT21ITU Unsigned32, + acSS7SignalingNodeTimersT24ITU Unsigned32, + acSS7SignalingNodeTimersT22ANSI Unsigned32, + acSS7SignalingNodeTimersT23ANSI Unsigned32, + acSS7SignalingNodeTimersT24ANSI Unsigned32, + acSS7SignalingNodeTimersT25ANSI Unsigned32, + acSS7SignalingNodeTimersT26ANSI Unsigned32, + acSS7SignalingNodeTimersT27ANSI Unsigned32, + acSS7SignalingNodeTimersT28ANSI Unsigned32, + acSS7SignalingNodeTimersT29ANSI Unsigned32, + acSS7SignalingNodeTimersT30ANSI Unsigned32 + } + + + + acSS7SignalingNodeTimersIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..4) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index Field for line. +AC INI-Param: SS7_SNTIMERS_INDEX" + ::= {acSS7SignalingNodeTimersEntry 1} + + + + acSS7SignalingNodeTimersIsUsed OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7SignalingNodeTimersEntry 2} + + + + acSS7SignalingNodeTimersAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_SNTIMERS_ACTION" + ::= {acSS7SignalingNodeTimersEntry 3} + + + + acSS7SignalingNodeTimersActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_SNTIMERS_ACTION_RESULT" + ::= {acSS7SignalingNodeTimersEntry 4} + + + + acSS7SignalingNodeTimersName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "String name for SN timer-set. +Access: Online. +AC INI-Param: SS7_SNTIMERS_NAME" + ::= {acSS7SignalingNodeTimersEntry 5} + + + + acSS7SignalingNodeTimersT6 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Delay to avoid message mis-sequencing on controlled rerouting. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T6" + ::= {acSS7SignalingNodeTimersEntry 6} + + + + acSS7SignalingNodeTimersT8 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Transfer prohibited inhibition timer (transient solution). +Access: Online. +AC INI-Param: SS7_SNTIMERS_T8" + ::= {acSS7SignalingNodeTimersEntry 7} + + + + acSS7SignalingNodeTimersT10 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting to repeat signalling route set test message. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T10" + ::= {acSS7SignalingNodeTimersEntry 8} + + + + acSS7SignalingNodeTimersT11 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Transfer restricted timer. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T11" + ::= {acSS7SignalingNodeTimersEntry 9} + + + + acSS7SignalingNodeTimersT15 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting to start signalling route set congestion test. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T15" + ::= {acSS7SignalingNodeTimersEntry 10} + + + + acSS7SignalingNodeTimersT16 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for route set congestion status update. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T16" + ::= {acSS7SignalingNodeTimersEntry 11} + + + + acSS7SignalingNodeTimersT18ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer within a signalling point whose MTP restarts for supervising +link and link set activation as well as the receipt of +routing information. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T18_ITU" + ::= {acSS7SignalingNodeTimersEntry 12} + + + + acSS7SignalingNodeTimersT19ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Supervision timer during MTP restart to avoid possible ping-pong +of TFP, TFR and TRA messages. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T19_ITU" + ::= {acSS7SignalingNodeTimersEntry 13} + + + + acSS7SignalingNodeTimersT20ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overall MTP restart timer at the signalling point whose MTP +restarts. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T20_ITU" + ::= {acSS7SignalingNodeTimersEntry 14} + + + + acSS7SignalingNodeTimersT21ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Overall MTP restart timer at a signalling point adjacent to +one whose MTP restarts. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T21_ITU" + ::= {acSS7SignalingNodeTimersEntry 15} + + + + acSS7SignalingNodeTimersT24ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Stabilising timer after removal of local processor outage, used +in LPO latching to RPO (national option). +Access: Online. +AC INI-Param: SS7_SNTIMERS_T24_ITU" + ::= {acSS7SignalingNodeTimersEntry 16} + + + + acSS7SignalingNodeTimersT22ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at restarting SP waiting for signalling links to bacome +available. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T22_ANSI" + ::= {acSS7SignalingNodeTimersEntry 17} + + + + acSS7SignalingNodeTimersT23ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at restarting SP, started after T22, waiting to receive +all traffic restart allowed messages. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T23_ANSI" + ::= {acSS7SignalingNodeTimersEntry 18} + + + + acSS7SignalingNodeTimersT24ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at restarting SP with transfer function, started after +T23, waiting to broadcast all traffic restart allowed messages. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T24_ANSI" + ::= {acSS7SignalingNodeTimersEntry 19} + + + + acSS7SignalingNodeTimersT25ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at SP adjacent to restarting SP waiting for traffic restart +allowed message. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T25_ANSI" + ::= {acSS7SignalingNodeTimersEntry 20} + + + + acSS7SignalingNodeTimersT26ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at restarting SP waiting to repeat traffic restart waiting +message. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T26_ANSI" + ::= {acSS7SignalingNodeTimersEntry 21} + + + + acSS7SignalingNodeTimersT27ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter is used to define the minimum duration of unavailability +for a full restart. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T27_ANSI" + ::= {acSS7SignalingNodeTimersEntry 22} + + + + acSS7SignalingNodeTimersT28ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer at SP adjacent to restarting SP waiting for traffic restart +waiting message. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T28_ANSI" + ::= {acSS7SignalingNodeTimersEntry 23} + + + + acSS7SignalingNodeTimersT29ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer started when TRA sent in response to unexpected TRA or +TRW. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T29_ANSI" + ::= {acSS7SignalingNodeTimersEntry 24} + + + + acSS7SignalingNodeTimersT30ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timer to limit sending of TFPs and TFRs in response to unexpected +TRA or TRW. +Access: Online. +AC INI-Param: SS7_SNTIMERS_T30_ANSI" + ::= {acSS7SignalingNodeTimersEntry 25} + + + + -- **************************************** + -- acSS7LinkSetTimers table declaration + -- **************************************** + acSS7LinkSetTimersTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkSetTimersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Timers 22} + + + + -- **************************************** + -- acSS7LinkSetTimers table entry + -- **************************************** + acSS7LinkSetTimersEntry OBJECT-TYPE + SYNTAX AcSS7LinkSetTimersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkSetTimersIndex} + ::= {acSS7LinkSetTimersTable 1} + + + + -- **************************************** + -- acSS7LinkSetTimers TABLE + -- **************************************** + AcSS7LinkSetTimersEntry ::= SEQUENCE { + acSS7LinkSetTimersIndex Unsigned32, + acSS7LinkSetTimersIsUsed INTEGER, + acSS7LinkSetTimersAction INTEGER, + acSS7LinkSetTimersActionResult INTEGER, + acSS7LinkSetTimersName SnmpAdminString, + acSS7LinkSetTimersT1SLT Unsigned32, + acSS7LinkSetTimersT2SLT Unsigned32, + acSS7LinkSetTimersT1 Unsigned32, + acSS7LinkSetTimersT2 Unsigned32, + acSS7LinkSetTimersT3 Unsigned32, + acSS7LinkSetTimersT4 Unsigned32, + acSS7LinkSetTimersT5 Unsigned32, + acSS7LinkSetTimersT7 Unsigned32, + acSS7LinkSetTimersT12 Unsigned32, + acSS7LinkSetTimersT13 Unsigned32, + acSS7LinkSetTimersT14 Unsigned32, + acSS7LinkSetTimersT17 Unsigned32, + acSS7LinkSetTimersT20ANSI Unsigned32, + acSS7LinkSetTimersT21ANSI Unsigned32, + acSS7LinkSetTimersT22ITU Unsigned32, + acSS7LinkSetTimersT23ITU Unsigned32 + } + + + + acSS7LinkSetTimersIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..4) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index Field for line. +AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX" + ::= {acSS7LinkSetTimersEntry 1} + + + + acSS7LinkSetTimersIsUsed OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7LinkSetTimersEntry 2} + + + + acSS7LinkSetTimersAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_LKSETTIMERS_ACTION" + ::= {acSS7LinkSetTimersEntry 3} + + + + acSS7LinkSetTimersActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT" + ::= {acSS7LinkSetTimersEntry 4} + + + + acSS7LinkSetTimersName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "String name for Linkset timer-set. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_NAME" + ::= {acSS7LinkSetTimersEntry 5} + + + + acSS7LinkSetTimersT1SLT OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Supervision timer for signalling link test acknowledgement message. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T1SLT" + ::= {acSS7LinkSetTimersEntry 6} + + + + acSS7LinkSetTimersT2SLT OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Interval timer for sending signalling link test messages. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T2SLT" + ::= {acSS7LinkSetTimersEntry 7} + + + + acSS7LinkSetTimersT1 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Delay to avoid message mis-sequencing on changeover. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T1" + ::= {acSS7LinkSetTimersEntry 8} + + + + acSS7LinkSetTimersT2 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for changeover acknowledgement. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T2" + ::= {acSS7LinkSetTimersEntry 9} + + + + acSS7LinkSetTimersT3 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time controlled diversion-delay to avoid mis-sequencing on changeback. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T3" + ::= {acSS7LinkSetTimersEntry 10} + + + + acSS7LinkSetTimersT4 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for changeback acknowledgement (first attempt). +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T4" + ::= {acSS7LinkSetTimersEntry 11} + + + + acSS7LinkSetTimersT5 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for changeback acknowledgement (second attempt). +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T5" + ::= {acSS7LinkSetTimersEntry 12} + + + + acSS7LinkSetTimersT7 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for signalling data link connection acknowledgement. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T7" + ::= {acSS7LinkSetTimersEntry 13} + + + + acSS7LinkSetTimersT12 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for uninhibit acknowledgement. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T12" + ::= {acSS7LinkSetTimersEntry 14} + + + + acSS7LinkSetTimersT13 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for force uninhibit. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T13" + ::= {acSS7LinkSetTimersEntry 15} + + + + acSS7LinkSetTimersT14 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Waiting for inhibition acknowledgement. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T14" + ::= {acSS7LinkSetTimersEntry 16} + + + + acSS7LinkSetTimersT17 OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Delay to avoid oscillation of initial alignment failure and +link restart. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T17" + ::= {acSS7LinkSetTimersEntry 17} + + + + acSS7LinkSetTimersT20ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Local inhibit test timer. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T20_ANSI" + ::= {acSS7LinkSetTimersEntry 18} + + + + acSS7LinkSetTimersT21ANSI OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Remote inhibit test timer. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T21_ANSI" + ::= {acSS7LinkSetTimersEntry 19} + + + + acSS7LinkSetTimersT22ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Local inhibit test timer. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T22_ITU" + ::= {acSS7LinkSetTimersEntry 20} + + + + acSS7LinkSetTimersT23ITU OBJECT-TYPE + SYNTAX Unsigned32 (500..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Remote inhibit test timer. +Access: Online. +AC INI-Param: SS7_LKSETTIMERS_T23_ITU" + ::= {acSS7LinkSetTimersEntry 21} + + + + acSS7Links OBJECT IDENTIFIER ::= {acSS7Configuration 3} + + + -- **************************************** + -- acSS7LinkCommon table declaration + -- **************************************** + acSS7LinkCommonTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkCommonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Links 21} + + + + -- **************************************** + -- acSS7LinkCommon table entry + -- **************************************** + acSS7LinkCommonEntry OBJECT-TYPE + SYNTAX AcSS7LinkCommonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkCommonIndex} + ::= {acSS7LinkCommonTable 1} + + + + -- **************************************** + -- acSS7LinkCommon TABLE + -- **************************************** + AcSS7LinkCommonEntry ::= SEQUENCE { + acSS7LinkCommonIndex Unsigned32, + acSS7LinkCommonRowStatus RowStatus, + acSS7LinkCommonAction INTEGER, + acSS7LinkCommonActionResult INTEGER, + acSS7LinkCommonName SnmpAdminString, + acSS7LinkCommonAdminState INTEGER, + acSS7LinkCommonOperState INTEGER, + acSS7LinkCommonTraceLevel INTEGER, + acSS7LinkCommonL2TypeSelector INTEGER, + acSS7LinkCommonL3TypeSelector INTEGER, + acSS7LinkCommonVariant INTEGER, + acSS7LinkCommonMtcBusy INTEGER, + acSS7LinkCommonRdcyBoardNum INTEGER, + acSS7LinkCommonMonSuFilterRequest INTEGER + } + + + + acSS7LinkCommonIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..63) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index Field for line. +AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD" + ::= {acSS7LinkCommonEntry 1} + + + + acSS7LinkCommonRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_LINK_ROWSTATUS" + ::= {acSS7LinkCommonEntry 2} + + + + acSS7LinkCommonAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + offLine(1) +, + inService(2) +, + activate(3) +, + deActivate(4) +, + inhibit(5) +, + unInhibit(6) +, + lpo(7) +, + lpr(8) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_LINK_ACTION" + ::= {acSS7LinkCommonEntry 3} + + + + acSS7LinkCommonActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_LINK_ACTION_RESULT" + ::= {acSS7LinkCommonEntry 4} + + + + acSS7LinkCommonName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "String name for Link paramaters. +Access: Online. +AC INI-Param: SS7_LINK_NAME" + ::= {acSS7LinkCommonEntry 5} + + + + acSS7LinkCommonAdminState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative state of singnalling link. +AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE" + ::= {acSS7LinkCommonEntry 6} + + + + acSS7LinkCommonOperState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational state of singnalling link. +AC INI-Param: SS7_LINK_OPERATIONAL_STATE" + ::= {acSS7LinkCommonEntry 7} + + + + acSS7LinkCommonTraceLevel OBJECT-TYPE + SYNTAX INTEGER { + traceLevel0(0) +, + traceLevel1(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Trace level of singnalling link (level 2). +Access: Online. +AC INI-Param: SS7_LINK_TRACE_LEVEL" + ::= {acSS7LinkCommonEntry 8} + + + + acSS7LinkCommonL2TypeSelector OBJECT-TYPE + SYNTAX INTEGER { + nonetype-L2(0) +, + mtp2(1) +, + m2ua-mgc(2) +, + ss7monitoring(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link layer 2 type - defines level 2 media of signaling link. +Access: Online. +AC INI-Param: SS7_LINK_L2_TYPE" + ::= {acSS7LinkCommonEntry 9} + + + + acSS7LinkCommonL3TypeSelector OBJECT-TYPE + SYNTAX INTEGER { + nonetype-L3(0) +, + m2ua-sg(1) +, + mtp3(2) +, + mtp2-tunneling(3) +, + mtp2OverIP(4) +, + ss7monitoring(5) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link high layer type - defines level 3 or L2 high layer of signalling +link. +Access: Online. +AC INI-Param: SS7_LINK_L3_TYPE" + ::= {acSS7LinkCommonEntry 10} + + + + acSS7LinkCommonVariant OBJECT-TYPE + SYNTAX INTEGER { + itu(1) +, + ansi(2) +, + china(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Variant (layer 2) of singnalling link (TDM). +Access: Online. +AC INI-Param: SS7_LINK_LAYER2_VARIANT" + ::= {acSS7LinkCommonEntry 11} + + + + acSS7LinkCommonMtcBusy OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link local busy indicator - if set, indicates link is busy due +to local mtc action. +AC INI-Param: SS7_LINK_MTC_BUSY" + ::= {acSS7LinkCommonEntry 12} + + + + acSS7LinkCommonRdcyBoardNum OBJECT-TYPE + SYNTAX INTEGER { + rdcyBoardNum0(0) +, + rdcyBoardNum1(1) +, + rdcyBoardNum2(2) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Board number in which the link is physically connected. +Access: Online. +AC INI-Param: SS7_LINK_RDCY_BOARD" + ::= {acSS7LinkCommonEntry 13} + + + + acSS7LinkCommonMonSuFilterRequest OBJECT-TYPE + SYNTAX INTEGER { + filterAll(0) +, + filterLSSUandFISU(1) +, + filterFISU(2) +, + noFilter(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SS7 Monitoring link SU filter- Defines the type of SU message +to filter. 0: Filter all types of SU messages +1: Filter LSSU and FISU messages +2: Filter only FISU messages +3: Do not filter any message. +Access: Online. +AC INI-Param: SS7_LINK_MON_SU_FILTER" + ::= {acSS7LinkCommonEntry 14} + + + + -- **************************************** + -- acSS7LinkTDM table declaration + -- **************************************** + acSS7LinkTDMTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkTDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Links 22} + + + + -- **************************************** + -- acSS7LinkTDM table entry + -- **************************************** + acSS7LinkTDMEntry OBJECT-TYPE + SYNTAX AcSS7LinkTDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkCommonIndex} + ::= {acSS7LinkTDMTable 1} + + + + -- **************************************** + -- acSS7LinkTDM TABLE + -- **************************************** + AcSS7LinkTDMEntry ::= SEQUENCE { + acSS7LinkTDMTrunkNumber Integer32, + acSS7LinkTDMTimeSlotNumber Unsigned32, + acSS7LinkTDMInhibit INTEGER, + acSS7LinkTDMMtp2Atts INTEGER, + acSS7LinkTDMCongestionLowMark Unsigned32, + acSS7LinkTDMCongestionHighMark Unsigned32, + acSS7LinkTDMBlock INTEGER + } + + + + acSS7LinkTDMTrunkNumber OBJECT-TYPE + SYNTAX Integer32 (-1..84) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Trunk number of singnalling link (TDM). +Access: Online. +AC INI-Param: SS7_LINK_TRUNK_NUMBER" + ::= {acSS7LinkTDMEntry 1} + + + + acSS7LinkTDMTimeSlotNumber OBJECT-TYPE + SYNTAX Unsigned32 (1..31) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Time-Slot number of singnalling link (TDM). +Access: Online. +AC INI-Param: SS7_LINK_TIMESLOT_NUMBER" + ::= {acSS7LinkTDMEntry 2} + + + + acSS7LinkTDMInhibit OBJECT-TYPE + SYNTAX INTEGER { + unInhibited(0) +, + inhibited(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link inhibit indicator - if set, indicates link is inhibited.. +AC INI-Param: SS7_LINK_INHIBITION" + ::= {acSS7LinkTDMEntry 3} + + + + acSS7LinkTDMMtp2Atts OBJECT-TYPE + SYNTAX INTEGER { + mtp2Atts0(0) +, + mtp2Atts1(1) +, + mtp2Atts2(2) +, + mtp2Atts3(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 attributes of singnalling link (TDM). +Access: Online. +AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES" + ::= {acSS7LinkTDMEntry 4} + + + + acSS7LinkTDMCongestionLowMark OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link congestion low mark of signalling link (TDM). +Access: Online. +AC INI-Param: SS7_CONGESTION_LOW_MARK" + ::= {acSS7LinkTDMEntry 5} + + + + acSS7LinkTDMCongestionHighMark OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Link congestion high mark of signalling link (TDM). +Access: Online. +AC INI-Param: SS7_CONGESTION_HIGH_MARK" + ::= {acSS7LinkTDMEntry 6} + + + + acSS7LinkTDMBlock OBJECT-TYPE + SYNTAX INTEGER { + l3linkunblocked(0) +, + l3linklocalblocked(1) +, + l3linkremoteblockde(2) +, + l3linklocalandremotelocked(3) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link blocked indicator. +AC INI-Param: SS7_LINK_BLOCKED" + ::= {acSS7LinkTDMEntry 7} + + + + -- **************************************** + -- acSS7LinkSigTran table declaration + -- **************************************** + acSS7LinkSigTranTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkSigTranEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Links 23} + + + + -- **************************************** + -- acSS7LinkSigTran table entry + -- **************************************** + acSS7LinkSigTranEntry OBJECT-TYPE + SYNTAX AcSS7LinkSigTranEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkCommonIndex} + ::= {acSS7LinkSigTranTable 1} + + + + -- **************************************** + -- acSS7LinkSigTran TABLE + -- **************************************** + AcSS7LinkSigTranEntry ::= SEQUENCE { + acSS7LinkSigTranGroupId Integer32, + acSS7LinkSigTranIfid Integer32 + } + + + + acSS7LinkSigTranGroupId OBJECT-TYPE + SYNTAX Integer32 (-1..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Group ID (M2UA) of signaling link. +Access: Online. +AC INI-Param: SS7_LINK_GROUP_ID" + ::= {acSS7LinkSigTranEntry 1} + + + + acSS7LinkSigTranIfid OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Interface ID (M2UA) of singnalling link. +Access: Online. +AC INI-Param: SS7_LINK_M2UA_IF_ID" + ::= {acSS7LinkSigTranEntry 2} + + + + -- **************************************** + -- acSS7LinkATM table declaration + -- **************************************** + acSS7LinkATMTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkATMEntry + MAX-ACCESS not-accessible + STATUS obsolete + DESCRIPTION + "" + ::= {acSS7Links 24} + + + + -- **************************************** + -- acSS7LinkATM table entry + -- **************************************** + acSS7LinkATMEntry OBJECT-TYPE + SYNTAX AcSS7LinkATMEntry + MAX-ACCESS not-accessible + STATUS obsolete + DESCRIPTION + "" + INDEX {acSS7LinkCommonIndex} + ::= {acSS7LinkATMTable 1} + + + + -- **************************************** + -- acSS7LinkATM TABLE + -- **************************************** + AcSS7LinkATMEntry ::= SEQUENCE { + acSS7LinkATMSAALLinkProfileNum Unsigned32, + acSS7LinkATMSAALLinkType INTEGER, + acSS7LinkATMSAALLinkInterfaceNum Unsigned32, + acSS7LinkATMSAALLinkVPI Unsigned32, + acSS7LinkATMSAALLinkVCI Unsigned32 + } + + + + acSS7LinkATMSAALLinkProfileNum OBJECT-TYPE + SYNTAX Unsigned32 (0..128) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ATM SAAL Link profile number. +Access: Online. +AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM" + ::= {acSS7LinkATMEntry 1} + + + + acSS7LinkATMSAALLinkType OBJECT-TYPE + SYNTAX INTEGER { + aTM-VCC-Type-PVC(0) +, + aTM-VCC-Type-SVC(1) + + } + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ATM SAAL link Type PVC/SVC. +Access: Online. +AC INI-Param: ATM_SAAL_LINK_TYPE" + ::= {acSS7LinkATMEntry 2} + + + + acSS7LinkATMSAALLinkInterfaceNum OBJECT-TYPE + SYNTAX Unsigned32 (0..128) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ATM SAAL link port num. +Access: Online. +AC INI-Param: ATM_SAAL_LINK_PORT_NUM" + ::= {acSS7LinkATMEntry 3} + + + + acSS7LinkATMSAALLinkVPI OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ATM SAAL link VPI. +Access: Online. +AC INI-Param: ATM_SAAL_LINK_VPI" + ::= {acSS7LinkATMEntry 4} + + + + acSS7LinkATMSAALLinkVCI OBJECT-TYPE + SYNTAX Unsigned32 (0..65536) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "ATM SAAL link VCI. +Access: Online. +AC INI-Param: ATM_SAAL_LINK_VCI" + ::= {acSS7LinkATMEntry 5} + + + + -- **************************************** + -- acSS7LinkTNL table declaration + -- **************************************** + acSS7LinkTNLTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkTNLEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Links 25} + + + + -- **************************************** + -- acSS7LinkTNL table entry + -- **************************************** + acSS7LinkTNLEntry OBJECT-TYPE + SYNTAX AcSS7LinkTNLEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkCommonIndex} + ::= {acSS7LinkTNLTable 1} + + + + -- **************************************** + -- acSS7LinkTNL TABLE + -- **************************************** + AcSS7LinkTNLEntry ::= SEQUENCE { + acSS7LinkTNLOtherSideLinkNum Unsigned32, + acSS7LinkTNLAlignmentMode INTEGER, + acSS7LinkTNLCongestionMode INTEGER, + acSS7LinkTNLWaitStartCompTimer Unsigned32, + acSS7LinkTNLOosStartDelayTimer Unsigned32, + acSS7LinkTNLWaitOtherSideInsvTimer Unsigned32 + } + + + + acSS7LinkTNLOtherSideLinkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..128) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling +link). +Access: Online. +AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER" + ::= {acSS7LinkTNLEntry 1} + + + + acSS7LinkTNLAlignmentMode OBJECT-TYPE + SYNTAX INTEGER { + normal(0) +, + emergency(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: Alignment mode of signalling links in tunnel. +Access: Online. +AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE" + ::= {acSS7LinkTNLEntry 2} + + + + acSS7LinkTNLCongestionMode OBJECT-TYPE + SYNTAX INTEGER { + accept(0) +, + discard(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: Congestion mode of signalling links in tunnel. +Access: Online. +AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE" + ::= {acSS7LinkTNLEntry 3} + + + + acSS7LinkTNLWaitStartCompTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: wait start complete timer. +Access: Online. +AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER" + ::= {acSS7LinkTNLEntry 4} + + + + acSS7LinkTNLOosStartDelayTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: OOS start delay timer. +Access: Online. +AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER" + ::= {acSS7LinkTNLEntry 5} + + + + acSS7LinkTNLWaitOtherSideInsvTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "MTP2 Tunneling: wait for other side to be in service timer. +Access: Online. +AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER" + ::= {acSS7LinkTNLEntry 6} + + + + acSS7Nodes OBJECT IDENTIFIER ::= {acSS7Configuration 4} + + + -- **************************************** + -- acSS7SignalingNode table declaration + -- **************************************** + acSS7SignalingNodeTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7SignalingNodeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Nodes 21} + + + + -- **************************************** + -- acSS7SignalingNode table entry + -- **************************************** + acSS7SignalingNodeEntry OBJECT-TYPE + SYNTAX AcSS7SignalingNodeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7SignalingNodeIndex} + ::= {acSS7SignalingNodeTable 1} + + + + -- **************************************** + -- acSS7SignalingNode TABLE + -- **************************************** + AcSS7SignalingNodeEntry ::= SEQUENCE { + acSS7SignalingNodeIndex Unsigned32, + acSS7SignalingNodeRowStatus RowStatus, + acSS7SignalingNodeAction INTEGER, + acSS7SignalingNodeActionResult INTEGER, + acSS7SignalingNodeName SnmpAdminString, + acSS7SignalingNodeTraceLevel INTEGER, + acSS7SignalingNodeAdminState INTEGER, + acSS7SignalingNodeOperState INTEGER, + acSS7SignalingNodeMtcBusy INTEGER, + acSS7SignalingNodeVariant INTEGER, + acSS7SignalingNodeNwIndicator INTEGER, + acSS7SignalingNodeSpStp INTEGER, + acSS7SignalingNodeTfc INTEGER, + acSS7SignalingNodeOpc Unsigned32, + acSS7SignalingNodeRouteSetCongestionWindow Unsigned32, + acSS7SignalingNodeTimersIdx INTEGER, + acSS7SignalingNodeIsupApp INTEGER, + acSS7SignalingNodeSccpApp INTEGER, + acSS7SignalingNodeBisupApp INTEGER, + acSS7SignalingNodeAlcapApp INTEGER, + acSS7SignalingNodeRdcyOpc Unsigned32, + acSS7SignalingNodeTupApp INTEGER, + acSS7SignalingNodeBiccApp INTEGER + } + + + + acSS7SignalingNodeIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " +AC INI-Param: SS7_SN_INDEX" + ::= {acSS7SignalingNodeEntry 1} + + + + acSS7SignalingNodeRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_SN_ROWSTATUS" + ::= {acSS7SignalingNodeEntry 2} + + + + acSS7SignalingNodeAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + stop(1) +, + start(2) +, + inService(3) +, + offLine(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_SN_ACTION" + ::= {acSS7SignalingNodeEntry 3} + + + + acSS7SignalingNodeActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_SN_ACTION_RESULT" + ::= {acSS7SignalingNodeEntry 4} + + + + acSS7SignalingNodeName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "String name for SN Params. +Access: Online. +AC INI-Param: SS7_SN_NAME" + ::= {acSS7SignalingNodeEntry 5} + + + + acSS7SignalingNodeTraceLevel OBJECT-TYPE + SYNTAX INTEGER { + traceLevel0(0) +, + traceLevel1(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Trace level of singnalling node (level 3). +Access: Online. +AC INI-Param: SS7_SN_TRACE_LEVEL" + ::= {acSS7SignalingNodeEntry 6} + + + + acSS7SignalingNodeAdminState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative state of singnalling node. +AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE" + ::= {acSS7SignalingNodeEntry 7} + + + + acSS7SignalingNodeOperState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational state of singnalling node. +AC INI-Param: SS7_SN_OPERATIONAL_STATE" + ::= {acSS7SignalingNodeEntry 8} + + + + acSS7SignalingNodeMtcBusy OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manual busy status of singnalling node. +AC INI-Param: SS7_SN_MTC_BUSY_STATUS" + ::= {acSS7SignalingNodeEntry 9} + + + + acSS7SignalingNodeVariant OBJECT-TYPE + SYNTAX INTEGER { + itu(1) +, + ansi(2) +, + china(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Variant of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_VARIANT" + ::= {acSS7SignalingNodeEntry 10} + + + + acSS7SignalingNodeNwIndicator OBJECT-TYPE + SYNTAX INTEGER { + international(0) +, + internationalSpare(1) +, + national(2) +, + nationalSpare(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Network Indicator of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_NI" + ::= {acSS7SignalingNodeEntry 11} + + + + acSS7SignalingNodeSpStp OBJECT-TYPE + SYNTAX INTEGER { + sp(0) +, + stp(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Routing function of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_SP_STP" + ::= {acSS7SignalingNodeEntry 12} + + + + acSS7SignalingNodeTfc OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "TFC function of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_TFC" + ::= {acSS7SignalingNodeEntry 13} + + + + acSS7SignalingNodeOpc OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Origination (local) point-code of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_OPC" + ::= {acSS7SignalingNodeEntry 14} + + + + acSS7SignalingNodeRouteSetCongestionWindow OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Routeset Congestion Size (messages) of singnalling node. +Access: Online. +AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE" + ::= {acSS7SignalingNodeEntry 15} + + + + acSS7SignalingNodeTimersIdx OBJECT-TYPE + SYNTAX INTEGER { + timersIdx0(0) +, + timersIdx1(1) +, + timersIdx2(2) +, + timersIdx3(3) +, + timersIdx4(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Index of SNTimers table used for this signaling node. +Access: Online. +AC INI-Param: SS7_SN_TIMERS_INDEX" + ::= {acSS7SignalingNodeEntry 16} + + + + acSS7SignalingNodeIsupApp OBJECT-TYPE + SYNTAX INTEGER { + nill(0) +, + ual(4) +, + l4Gen(7) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Level 4 application that handles ISUP traffic for this singnalling +node. +Access: Online. +AC INI-Param: SS7_SN_ISUP_APP" + ::= {acSS7SignalingNodeEntry 17} + + + + acSS7SignalingNodeSccpApp OBJECT-TYPE + SYNTAX INTEGER { + nill(0) +, + ual(4) +, + l4Gen(7) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Level 4 application that handles SCCP traffic for this singnalling +node. +Access: Online. +AC INI-Param: SS7_SN_SCCP_APP" + ::= {acSS7SignalingNodeEntry 18} + + + + acSS7SignalingNodeBisupApp OBJECT-TYPE + SYNTAX INTEGER { + nill(0) +, + ual(4) +, + l4Gen(7) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Level 4 application that handles BISUP traffic for this singnalling +node. +Access: Online. +AC INI-Param: SS7_SN_BISUP_APP" + ::= {acSS7SignalingNodeEntry 19} + + + + acSS7SignalingNodeAlcapApp OBJECT-TYPE + SYNTAX INTEGER { + nill(0) +, + ual(4) +, + alcap(5) +, + l4Gen(7) + + } + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "Level 4 application that handles ALCAP traffic for this singnalling +node. +Access: Online. +AC INI-Param: SS7_SN_ALCAP_APP" + ::= {acSS7SignalingNodeEntry 20} + + + + acSS7SignalingNodeRdcyOpc OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Internal point-code of singnalling node - in case of SS7 shared +point code. +AC INI-Param: SS7_SN_RDCY_OPC" + ::= {acSS7SignalingNodeEntry 21} + + + + acSS7SignalingNodeTupApp OBJECT-TYPE + SYNTAX INTEGER { + nill(0) +, + ual(4) +, + l4Gen(7) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Level 4 application that handles TUP traffic for this signaling +node. +Access: Online. +AC INI-Param: SS7_SN_TUP_APP" + ::= {acSS7SignalingNodeEntry 22} + + + + acSS7SignalingNodeBiccApp OBJECT-TYPE + SYNTAX INTEGER { + nil(0) +, + ual(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Level 4 application that handles BICC traffic for this signaling +node. +Access: Online. +AC INI-Param: SS7_SN_BICC_APP" + ::= {acSS7SignalingNodeEntry 23} + + + + acSS7LinkSets OBJECT IDENTIFIER ::= {acSS7Nodes 31} + + + -- **************************************** + -- acSS7LinkSet table declaration + -- **************************************** + acSS7LinkSetTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkSetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7LinkSets 21} + + + + -- **************************************** + -- acSS7LinkSet table entry + -- **************************************** + acSS7LinkSetEntry OBJECT-TYPE + SYNTAX AcSS7LinkSetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkSetSNIndex,acSS7LinkSetLksetIndex} + ::= {acSS7LinkSetTable 1} + + + + -- **************************************** + -- acSS7LinkSet TABLE + -- **************************************** + AcSS7LinkSetEntry ::= SEQUENCE { + acSS7LinkSetSNIndex Unsigned32, + acSS7LinkSetLksetIndex Unsigned32, + acSS7LinkSetRowStatus RowStatus, + acSS7LinkSetAction INTEGER, + acSS7LinkSetActionResult INTEGER, + acSS7LinkSetName SnmpAdminString, + acSS7LinkSetAdminState INTEGER, + acSS7LinkSetOperState INTEGER, + acSS7LinkSetMtcBusyState INTEGER, + acSS7LinkSetDPC Unsigned32, + acSS7LinkSetLinksMask Unsigned32, + acSS7LinkSetLinksAltMask Unsigned32, + acSS7LinkSetTimersIdx INTEGER + } + + + + acSS7LinkSetSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First Index Field for line. +AC INI-Param: SS7_LINKSET_SN_INDEX" + ::= {acSS7LinkSetEntry 1} + + + + acSS7LinkSetLksetIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..31) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second Index Field for line. +AC INI-Param: SS7_LINKSET_LINKSET_INDEX" + ::= {acSS7LinkSetEntry 2} + + + + acSS7LinkSetRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_LINKSET_ROWSTATUS" + ::= {acSS7LinkSetEntry 3} + + + + acSS7LinkSetAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + offLine(1) +, + inService(2) +, + activate(3) +, + deActivate(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_LINKSET_ACTION" + ::= {acSS7LinkSetEntry 4} + + + + acSS7LinkSetActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_SN_ACTION_RESULT" + ::= {acSS7LinkSetEntry 5} + + + + acSS7LinkSetName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "String name for LINKSET Params. +Access: Online. +AC INI-Param: SS7_LINKSET_NAME" + ::= {acSS7LinkSetEntry 6} + + + + acSS7LinkSetAdminState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative state of singnalling linkset. +AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE" + ::= {acSS7LinkSetEntry 7} + + + + acSS7LinkSetOperState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational state of singnalling linkset. +AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE" + ::= {acSS7LinkSetEntry 8} + + + + acSS7LinkSetMtcBusyState OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manual busy status of singnalling linkset. +AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS" + ::= {acSS7LinkSetEntry 9} + + + + acSS7LinkSetDPC OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Destination Point-Code of singnalling linkset. +Access: Online. +AC INI-Param: SS7_LINKSET_DPC" + ::= {acSS7LinkSetEntry 10} + + + + acSS7LinkSetLinksMask OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Mask for links within singnalling linkset. +Access: Online. +AC INI-Param: SS7_LINKSET_MASK" + ::= {acSS7LinkSetEntry 11} + + + + acSS7LinkSetLinksAltMask OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Alternate mask for links within singnalling linkset. +Access: Online. +AC INI-Param: SS7_LINKSET_ALTERNATE_MASK" + ::= {acSS7LinkSetEntry 12} + + + + acSS7LinkSetTimersIdx OBJECT-TYPE + SYNTAX INTEGER { + timersIdx0(0) +, + timersIdx1(1) +, + timersIdx2(2) +, + timersIdx3(3) +, + timersIdx4(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Timers Index of singnalling linkset. +Access: Online. +AC INI-Param: SS7_LINKSET_TIMERS_INDEX" + ::= {acSS7LinkSetEntry 13} + + + + -- **************************************** + -- acSS7LinkSetLink table declaration + -- **************************************** + acSS7LinkSetLinkTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7LinkSetLinkEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7LinkSets 22} + + + + -- **************************************** + -- acSS7LinkSetLink table entry + -- **************************************** + acSS7LinkSetLinkEntry OBJECT-TYPE + SYNTAX AcSS7LinkSetLinkEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7LinkSetLinkSNIndex,acSS7LinkSetLinkLinksetIndex,acSS7LinkSetLinkInnerLinkIndex} + ::= {acSS7LinkSetLinkTable 1} + + + + -- **************************************** + -- acSS7LinkSetLink TABLE + -- **************************************** + AcSS7LinkSetLinkEntry ::= SEQUENCE { + acSS7LinkSetLinkSNIndex Unsigned32, + acSS7LinkSetLinkLinksetIndex Unsigned32, + acSS7LinkSetLinkInnerLinkIndex Unsigned32, + acSS7LinkSetLinkRowStatus RowStatus, + acSS7LinkSetLinkAction INTEGER, + acSS7LinkSetLinkActionResult INTEGER, + acSS7LinkSetLinkLinkNo Unsigned32, + acSS7LinkSetLinkLinkSlc Unsigned32 + } + + + + acSS7LinkSetLinkSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First Index Field for line: Signalling Node Number. +AC INI-Param: SS7_LINKSETLINK_SN_INDEX" + ::= {acSS7LinkSetLinkEntry 1} + + + + acSS7LinkSetLinkLinksetIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..31) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second Index Field for line: Signalling Linkset Number. +AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX" + ::= {acSS7LinkSetLinkEntry 2} + + + + acSS7LinkSetLinkInnerLinkIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..7) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Third Index Field for line: Inner Link Index in Signalling Linkset. +AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX" + ::= {acSS7LinkSetLinkEntry 3} + + + + acSS7LinkSetLinkRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_LINKSETLINK_ROWSTATUS" + ::= {acSS7LinkSetLinkEntry 4} + + + + acSS7LinkSetLinkAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_LINKSETLINK_ACTION" + ::= {acSS7LinkSetLinkEntry 5} + + + + acSS7LinkSetLinkActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Management field for ACTIONS RESULT. +AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT" + ::= {acSS7LinkSetLinkEntry 6} + + + + acSS7LinkSetLinkLinkNo OBJECT-TYPE + SYNTAX Unsigned32 (0..128) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Physical number of signalling link which is part of the Linkset. +Access: Online. +AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER" + ::= {acSS7LinkSetLinkEntry 7} + + + + acSS7LinkSetLinkLinkSlc OBJECT-TYPE + SYNTAX Unsigned32 (0..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SLC number of signaling link which is part of the Linkset. +Access: Online. +AC INI-Param: SS7_LINKSETLINK_LINK_SLC" + ::= {acSS7LinkSetLinkEntry 8} + + + + acSS7RouteSets OBJECT IDENTIFIER ::= {acSS7Nodes 32} + + + -- **************************************** + -- acSS7RouteSet table declaration + -- **************************************** + acSS7RouteSetTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7RouteSetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7RouteSets 21} + + + + -- **************************************** + -- acSS7RouteSet table entry + -- **************************************** + acSS7RouteSetEntry OBJECT-TYPE + SYNTAX AcSS7RouteSetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7RouteSetSNIndex,acSS7RouteSetIndex} + ::= {acSS7RouteSetTable 1} + + + + -- **************************************** + -- acSS7RouteSet TABLE + -- **************************************** + AcSS7RouteSetEntry ::= SEQUENCE { + acSS7RouteSetSNIndex Unsigned32, + acSS7RouteSetIndex Unsigned32, + acSS7RouteSetRowStatus RowStatus, + acSS7RouteSetAction INTEGER, + acSS7RouteSetActionResult INTEGER, + acSS7RouteSetName SnmpAdminString, + acSS7RouteSetAdminState INTEGER, + acSS7RouteSetOperState INTEGER, + acSS7RouteSetDPC Unsigned32, + acSS7RouteSetRouteMask Unsigned32 + } + + + + acSS7RouteSetSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First Index Field for line: Signalling Node Number. +AC INI-Param: SS7_ROUTESET_SN_INDEX" + ::= {acSS7RouteSetEntry 1} + + + + acSS7RouteSetIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..29) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second Index Field for line: Signalling Routeset Number. +AC INI-Param: SS7_ROUTESET_INDEX" + ::= {acSS7RouteSetEntry 2} + + + + acSS7RouteSetRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_ROUTESET_ROWSTATUS" + ::= {acSS7RouteSetEntry 3} + + + + acSS7RouteSetAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + offLine(1) +, + inService(2) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_ROUTESET_ACTION" + ::= {acSS7RouteSetEntry 4} + + + + acSS7RouteSetActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_ROUTESET_ACTION_RESULT" + ::= {acSS7RouteSetEntry 5} + + + + acSS7RouteSetName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "String name for ROUTESET Params. +Access: Online. +AC INI-Param: SS7_ROUTESET_NAME" + ::= {acSS7RouteSetEntry 6} + + + + acSS7RouteSetAdminState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative state of signalling route set. +AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE" + ::= {acSS7RouteSetEntry 7} + + + + acSS7RouteSetOperState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational state of signalling route set. +AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE" + ::= {acSS7RouteSetEntry 8} + + + + acSS7RouteSetDPC OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Destination Point-Code of singnalling routesetset. +Access: Online. +AC INI-Param: SS7_ROUTESET_DPC" + ::= {acSS7RouteSetEntry 9} + + + + acSS7RouteSetRouteMask OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Mask for route within signaling routeset. +Access: Online. +AC INI-Param: SS7_ROUTESET_MASK" + ::= {acSS7RouteSetEntry 10} + + + + -- **************************************** + -- acSS7RouteSetRoute table declaration + -- **************************************** + acSS7RouteSetRouteTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7RouteSetRouteEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7RouteSets 22} + + + + -- **************************************** + -- acSS7RouteSetRoute table entry + -- **************************************** + acSS7RouteSetRouteEntry OBJECT-TYPE + SYNTAX AcSS7RouteSetRouteEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7RouteSetRouteSNIndex,acSS7RouteSetRouteRoutesetIndex,acSS7RouteSetRouteInnerRouteIndex} + ::= {acSS7RouteSetRouteTable 1} + + + + -- **************************************** + -- acSS7RouteSetRoute TABLE + -- **************************************** + AcSS7RouteSetRouteEntry ::= SEQUENCE { + acSS7RouteSetRouteSNIndex Unsigned32, + acSS7RouteSetRouteRoutesetIndex Unsigned32, + acSS7RouteSetRouteInnerRouteIndex Unsigned32, + acSS7RouteSetRouteRowStatus RowStatus, + acSS7RouteSetRouteAction INTEGER, + acSS7RouteSetRouteActionResult INTEGER, + acSS7RouteSetRouteLinkSetNo Unsigned32, + acSS7RouteSetRoutePriority Unsigned32 + } + + + + acSS7RouteSetRouteSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First Index Field for line: Signalling Node Number. +AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX" + ::= {acSS7RouteSetRouteEntry 1} + + + + acSS7RouteSetRouteRoutesetIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..29) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second Index Field for line: Signalling Routeset Number. +AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX" + ::= {acSS7RouteSetRouteEntry 2} + + + + acSS7RouteSetRouteInnerRouteIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..3) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Third Index Field for line: Inner Route Index in Signalling +Routeset. +AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX" + ::= {acSS7RouteSetRouteEntry 3} + + + + acSS7RouteSetRouteRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS" + ::= {acSS7RouteSetRouteEntry 4} + + + + acSS7RouteSetRouteAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "management Field for ACTIONS. +AC INI-Param: SS7_ROUTESETROUTE_ACTION" + ::= {acSS7RouteSetRouteEntry 5} + + + + acSS7RouteSetRouteActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT" + ::= {acSS7RouteSetRouteEntry 6} + + + + acSS7RouteSetRouteLinkSetNo OBJECT-TYPE + SYNTAX Unsigned32 (0..128) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Number of signalling linkset which is part of the Routeset. +Access: Online. +AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER" + ::= {acSS7RouteSetRouteEntry 7} + + + + acSS7RouteSetRoutePriority OBJECT-TYPE + SYNTAX Unsigned32 (0..254) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Priority of route within routeset. +Access: Online. +AC INI-Param: SS7_ROUTESETROUTE_PRIORITY" + ::= {acSS7RouteSetRouteEntry 8} + + + + acSS7AliasPointCode OBJECT IDENTIFIER ::= {acSS7Nodes 33} + + + -- **************************************** + -- acSS7APC table declaration + -- **************************************** + acSS7APCTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7APCEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7AliasPointCode 21} + + + + -- **************************************** + -- acSS7APC table entry + -- **************************************** + acSS7APCEntry OBJECT-TYPE + SYNTAX AcSS7APCEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7APCSNIndex,acSS7APCIndex} + ::= {acSS7APCTable 1} + + + + -- **************************************** + -- acSS7APC TABLE + -- **************************************** + AcSS7APCEntry ::= SEQUENCE { + acSS7APCSNIndex Unsigned32, + acSS7APCIndex Unsigned32, + acSS7APCRowStatus RowStatus, + acSS7APCAction INTEGER, + acSS7APCActionResult INTEGER, + acSS7APCPC Unsigned32, + acSS7APCSNI Unsigned32, + acSS7APCName SnmpAdminString, + acSS7APCMtcBusy INTEGER, + acSS7APCAdminState INTEGER, + acSS7APCOperState INTEGER + } + + + + acSS7APCSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First Index Field for line: Signaling Node Number. +AC INI-Param: SS7_APC_SN_INDEX" + ::= {acSS7APCEntry 1} + + + + acSS7APCIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second Index Field for line: Alias PC index. +AC INI-Param: SS7_APC_INNER_INDEX" + ::= {acSS7APCEntry 2} + + + + acSS7APCRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS Field for line. +AC INI-Param: SS7_APC_ROWSTATUS" + ::= {acSS7APCEntry 3} + + + + acSS7APCAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + offLine(1) +, + inService(2) +, + activate(3) +, + deActivate(4) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Management field for ACTIONS. +AC INI-Param: SS7_APC_ACTION" + ::= {acSS7APCEntry 4} + + + + acSS7APCActionResult OBJECT-TYPE + SYNTAX INTEGER { + succeeded(0) +, + inProgress(1) +, + failed(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "management Field for ACTIONS RESULT. +AC INI-Param: SS7_APC_ACTION_RESULT" + ::= {acSS7APCEntry 5} + + + + acSS7APCPC OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Alias Point-Code of signaling node. +Access: Online. +AC INI-Param: SS7_APC_PC" + ::= {acSS7APCEntry 6} + + + + acSS7APCSNI OBJECT-TYPE + SYNTAX Unsigned32 (2..5) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SNI (Signaling Network Indicator) of Alias Point-Code. +Access: Online. +AC INI-Param: SS7_APC_SNI" + ::= {acSS7APCEntry 7} + + + + acSS7APCName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "String name for Alias PC parameters. +Access: Online. +AC INI-Param: SS7_ALIAS_PC_NAME" + ::= {acSS7APCEntry 8} + + + + acSS7APCMtcBusy OBJECT-TYPE + SYNTAX INTEGER { + no(0) +, + yes(1) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manual busy status of Alias PC. +AC INI-Param: SS7_ALIAS_PC_MTC_BUSY" + ::= {acSS7APCEntry 9} + + + + acSS7APCAdminState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative state of Alias PC. +AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE" + ::= {acSS7APCEntry 10} + + + + acSS7APCOperState OBJECT-TYPE + SYNTAX INTEGER { + offLine(0) +, + busy(1) +, + inService(2) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operational state of Alias PC. +AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE" + ::= {acSS7APCEntry 11} + + + + acSS7SigTran OBJECT IDENTIFIER ::= {acSS7Configuration 5} + + + acSS7SigTranM3UATrafficBehavior OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + deactivate(1) +, + sIPO(2) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the M3UA behavior when the SS7 links are up, but there +is no association to the soft switch. + +0 = NONE (no special behavior) +1 = DEACTIVATE (busy links) +2 = SIPO (LPO links). +Access: Offline. +AC INI-Param: SS7M3UATrafficBehavior" + ::= {acSS7SigTran 1} + + + + -- **************************************** + -- acSS7SigTranIFGroup table declaration + -- **************************************** + acSS7SigTranIFGroupTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7SigTranIFGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7SigTran 21} + + + + -- **************************************** + -- acSS7SigTranIFGroup table entry + -- **************************************** + acSS7SigTranIFGroupEntry OBJECT-TYPE + SYNTAX AcSS7SigTranIFGroupEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7SigTranIFGroupIndex} + ::= {acSS7SigTranIFGroupTable 1} + + + + -- **************************************** + -- acSS7SigTranIFGroup TABLE + -- **************************************** + AcSS7SigTranIFGroupEntry ::= SEQUENCE { + acSS7SigTranIFGroupIndex Unsigned32, + acSS7SigTranIFGroupRowStatus RowStatus, + acSS7SigTranIFGroupAction INTEGER, + acSS7SigTranIFGroupActionResult Unsigned32, + acSS7SigTranIFGroupId Unsigned32, + acSS7SigTranIFGroupSgMgc INTEGER, + acSS7SigTranIFGroupSignalingLayer INTEGER, + acSS7SigTranIFGroupTrafMode INTEGER, + acSS7SigTranIFGroupRecovTimer Unsigned32, + acSS7SigTranIFGroupAckTimer Unsigned32, + acSS7SigTranIFGroupHBTimer Unsigned32, + acSS7SigTranIFGroupMinAsp Unsigned32, + acSS7SigTranIFGroupBehavior Unsigned32, + acSS7SigTranIFGroupSCTPInst Unsigned32, + acSS7SigTranIFGroupSCTPLocalPort Unsigned32, + acSS7SigTranIFGroupNetwork INTEGER, + acSS7SigTranIFGroupSCTPDestPort Unsigned32, + acSS7SigTranIFGroupDestIp IpAddress, + acSS7SigTranIFGroupSCTPMaxInbStreams Unsigned32, + acSS7SigTranIFGroupSCTPMaxOutbStreams Unsigned32, + acSS7SigTranIFGroupRdcyBoardNum Unsigned32, + acSS7SigTranIFGroupRoutingContextIndex Integer32, + acSS7SigTranIFGroupRoutingContextValue Integer32, + acSS7SigTranIFGroupNetworkAppearance Integer32 + } + + + + acSS7SigTranIFGroupIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..15) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index field for line. +AC INI-Param: SS7_SIG_IF_GR_INDEX" + ::= {acSS7SigTranIFGroupEntry 1} + + + + acSS7SigTranIFGroupRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS field for line. +AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS" + ::= {acSS7SigTranIFGroupEntry 2} + + + + acSS7SigTranIFGroupAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + activate(1) +, + deActivate(2) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Management field for ACTION. +AC INI-Param: SS7_SIG_IF_GR_ACTION" + ::= {acSS7SigTranIFGroupEntry 3} + + + + acSS7SigTranIFGroupActionResult OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Management field for ACTION RESULT. +AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT" + ::= {acSS7SigTranIFGroupEntry 4} + + + + acSS7SigTranIFGroupId OBJECT-TYPE + SYNTAX Unsigned32 (0..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface +Group Id. +Access: Online. +AC INI-Param: SS7_IF_GR_ID" + ::= {acSS7SigTranIFGroupEntry 5} + + + + acSS7SigTranIFGroupSgMgc OBJECT-TYPE + SYNTAX INTEGER { + nat(1) +, + mgc(77) +, + sg(83) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Interface Group function - Signaling Gateway (SG) or Media Gateway +Controller (MGC). +Access: Online. +AC INI-Param: SS7_SIG_SG_MGC" + ::= {acSS7SigTranIFGroupEntry 6} + + + + acSS7SigTranIFGroupSignalingLayer OBJECT-TYPE + SYNTAX INTEGER { + noLayer(0) +, + iua(1) +, + m2ua(2) +, + m3ua(3) +, + m2tunnel(4) +, + dua(6) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "UAL type of interface group: +0 = none +1 = iua +2 = m2ua +3 = m3ua +4 = m2tunnel +6 = dua. +Access: Online. +AC INI-Param: SS7_SIG_LAYER" + ::= {acSS7SigTranIFGroupEntry 7} + + + + acSS7SigTranIFGroupTrafMode OBJECT-TYPE + SYNTAX INTEGER { + override(1) +, + loadShare(2) +, + broadcast(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Traffic mode of interface group. +Access: Online. +AC INI-Param: SS7_SIG_TRAF_MODE" + ::= {acSS7SigTranIFGroupEntry 8} + + + + acSS7SigTranIFGroupRecovTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..10000000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "T(r) - recovery timer (in msecs) of interface group. +Access: Online. +AC INI-Param: SS7_SIG_T_REC" + ::= {acSS7SigTranIFGroupEntry 9} + + + + acSS7SigTranIFGroupAckTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..10000000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group. +Access: Online. +AC INI-Param: SS7_SIG_T_ACK" + ::= {acSS7SigTranIFGroupEntry 10} + + + + acSS7SigTranIFGroupHBTimer OBJECT-TYPE + SYNTAX Unsigned32 (0..10000000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "T(beat) - Heartbeat Timer (in msecs) of interface group. +Access: Online. +AC INI-Param: SS7_SIG_T_HB" + ::= {acSS7SigTranIFGroupEntry 11} + + + + acSS7SigTranIFGroupMinAsp OBJECT-TYPE + SYNTAX Unsigned32 (1..10) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Minimal ASP (Application Server Process) number in interface +group(minimum = 1). +Access: Online. +AC INI-Param: SS7_SIG_MIN_ASP" + ::= {acSS7SigTranIFGroupEntry 12} + + + + acSS7SigTranIFGroupBehavior OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Behavior bit of interface group. +Access: Online. +AC INI-Param: SS7_SIG_BEHAVIOUR" + ::= {acSS7SigTranIFGroupEntry 13} + + + + acSS7SigTranIFGroupSCTPInst OBJECT-TYPE + SYNTAX Unsigned32 (0..65534) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SCTP (Stream Control Transmission Protocol) instance of interface +group. +AC INI-Param: SS7_SCTP_INSTANCE" + ::= {acSS7SigTranIFGroupEntry 14} + + + + acSS7SigTranIFGroupSCTPLocalPort OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Local SCTP (Stream Control Transmission Protocol) port of interface +group. +Access: Online. +AC INI-Param: SS7_LOCAL_SCTP_PORT" + ::= {acSS7SigTranIFGroupEntry 15} + + + + acSS7SigTranIFGroupNetwork OBJECT-TYPE + SYNTAX INTEGER { + itu(1) +, + ansi(2) +, + china(3) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Network variant of interface group. +Access: Online. +AC INI-Param: SS7_SIG_NETWORK" + ::= {acSS7SigTranIFGroupEntry 16} + + + + acSS7SigTranIFGroupSCTPDestPort OBJECT-TYPE + SYNTAX Unsigned32 (0..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Destination SCTP (Stream Control Transmission Protocol) port. +Access: Online. +AC INI-Param: SS7_DEST_SCTP_PORT" + ::= {acSS7SigTranIFGroupEntry 17} + + + + acSS7SigTranIFGroupDestIp OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Destination SCTP (Stream Control Transmission Protocol) IP address. +Access: Online. +AC INI-Param: SS7_DEST_IP" + ::= {acSS7SigTranIFGroupEntry 18} + + + + acSS7SigTranIFGroupSCTPMaxInbStreams OBJECT-TYPE + SYNTAX Unsigned32 (2..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Maximum inbound streams in interface group. +Access: Online. +AC INI-Param: SS7_MGC_MX_IN_STREAM" + ::= {acSS7SigTranIFGroupEntry 19} + + + + acSS7SigTranIFGroupSCTPMaxOutbStreams OBJECT-TYPE + SYNTAX Unsigned32 (2..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Number of output streams required in interface group. +Access: Online. +AC INI-Param: SS7_MGC_NUM_OUT_STREAM" + ::= {acSS7SigTranIFGroupEntry 20} + + + + acSS7SigTranIFGroupRdcyBoardNum OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the SIGTRAN (Signaling Transport) +group redundancy board number. +Access: Online. +AC INI-Param: RdcyBoardNum" + ::= {acSS7SigTranIFGroupEntry 21} + + + + acSS7SigTranIFGroupRoutingContextIndex OBJECT-TYPE + SYNTAX Integer32 (-1..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Entry in Routing Context table, that contains the routing context +rules for this interface group. +Access: Online. +AC INI-Param: SS7_SIG_RC_INDEX" + ::= {acSS7SigTranIFGroupEntry 22} + + + + acSS7SigTranIFGroupRoutingContextValue OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Routing context value for this interface group (AS). +Access: Online. +AC INI-Param: SS7_SIG_RC_VALUE" + ::= {acSS7SigTranIFGroupEntry 23} + + + + acSS7SigTranIFGroupNetworkAppearance OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Network Appearance value for this interface group (AS). +Access: Online. +AC INI-Param: SS7_SIG_NETWORK_APPEARANCE" + ::= {acSS7SigTranIFGroupEntry 24} + + + + -- **************************************** + -- acSS7SigTranIFID table declaration + -- **************************************** + acSS7SigTranIFIDTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7SigTranIFIDEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7SigTran 22} + + + + -- **************************************** + -- acSS7SigTranIFID table entry + -- **************************************** + acSS7SigTranIFIDEntry OBJECT-TYPE + SYNTAX AcSS7SigTranIFIDEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7SigTranIFIDIndex} + ::= {acSS7SigTranIFIDTable 1} + + + + -- **************************************** + -- acSS7SigTranIFID TABLE + -- **************************************** + AcSS7SigTranIFIDEntry ::= SEQUENCE { + acSS7SigTranIFIDIndex Unsigned32, + acSS7SigTranIFIDRowStatus RowStatus, + acSS7SigTranIFIDAction INTEGER, + acSS7SigTranIFIDActionResult Unsigned32, + acSS7SigTranIFIDValue Unsigned32, + acSS7SigTranIFIDName SnmpAdminString, + acSS7SigTranIFIDOwnerGroup Integer32, + acSS7SigTranIFIDSignalingLayer INTEGER, + acSS7SigTranIFIDNai Integer32, + acSS7SigTranIFIDM3UASpc Unsigned32 + } + + + + acSS7SigTranIFIDIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index field for line. +AC INI-Param: SS7_SIG_IF_ID_INDEX" + ::= {acSS7SigTranIFIDEntry 1} + + + + acSS7SigTranIFIDRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS field for line. +AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS" + ::= {acSS7SigTranIFIDEntry 2} + + + + acSS7SigTranIFIDAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + activate(1) +, + deActivate(2) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Management field for ACTION. +AC INI-Param: SS7_SIG_IF_ID_ACTION" + ::= {acSS7SigTranIFIDEntry 3} + + + + acSS7SigTranIFIDActionResult OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Management field for ACTION RESULT. +AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT" + ::= {acSS7SigTranIFIDEntry 4} + + + + acSS7SigTranIFIDValue OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface +ID value. +Access: Online. +AC INI-Param: SS7_SIG_IF_ID_VALUE" + ::= {acSS7SigTranIFIDEntry 5} + + + + acSS7SigTranIFIDName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE (0..15)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface +ID name (text string). +Access: Online. +AC INI-Param: SS7_SIG_IF_ID_NAME" + ::= {acSS7SigTranIFIDEntry 6} + + + + acSS7SigTranIFIDOwnerGroup OBJECT-TYPE + SYNTAX Integer32 (-1..65534) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Owner group of interface id. +Access: Online. +AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP" + ::= {acSS7SigTranIFIDEntry 7} + + + + acSS7SigTranIFIDSignalingLayer OBJECT-TYPE + SYNTAX INTEGER { + noLayer(0) +, + iua(1) +, + m2ua(2) +, + m2tunnel(4) +, + dua(6) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "UAL Type of interface id: +0 = none +1 = iua +2 = m2ua +4 = m2tunnel +6 = dua. +Access: Online. +AC INI-Param: SS7_SIG_IF_ID_LAYER" + ::= {acSS7SigTranIFIDEntry 8} + + + + acSS7SigTranIFIDNai OBJECT-TYPE + SYNTAX Integer32 (-2..124) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "NAI of interface id. +Access: Online. +AC INI-Param: SS7_SIG_IF_ID_NAI" + ::= {acSS7SigTranIFIDEntry 9} + + + + acSS7SigTranIFIDM3UASpc OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the SIGTRAN (Signaling Transport) +M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC. +Access: Online. +AC INI-Param: SS7_SIG_M3UA_SPC" + ::= {acSS7SigTranIFIDEntry 10} + + + + -- **************************************** + -- acSS7M3UAStaticRouting table declaration + -- **************************************** + acSS7M3UAStaticRoutingTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7M3UAStaticRoutingEntry + MAX-ACCESS not-accessible + STATUS obsolete + DESCRIPTION + "" + ::= {acSS7SigTran 23} + + + + -- **************************************** + -- acSS7M3UAStaticRouting table entry + -- **************************************** + acSS7M3UAStaticRoutingEntry OBJECT-TYPE + SYNTAX AcSS7M3UAStaticRoutingEntry + MAX-ACCESS not-accessible + STATUS obsolete + DESCRIPTION + "" + INDEX {acSS7M3UAStaticRoutingIndex} + ::= {acSS7M3UAStaticRoutingTable 1} + + + + -- **************************************** + -- acSS7M3UAStaticRouting TABLE + -- **************************************** + AcSS7M3UAStaticRoutingEntry ::= SEQUENCE { + acSS7M3UAStaticRoutingIndex Unsigned32, + acSS7M3UAStaticRoutingRowStatus RowStatus, + acSS7M3UAStaticRoutingAction INTEGER, + acSS7M3UAStaticRoutingActionResult Unsigned32, + acSS7M3UAStaticRoutingOwnerInterfaceGroup Unsigned32, + acSS7M3UAStaticRoutingRC Unsigned32, + acSS7M3UAStaticRoutingDestinationPointCode Unsigned32, + acSS7M3UAStaticRoutingNetworkAppearence Unsigned32, + acSS7M3UAStaticRoutingSeriviceIndicatorList Unsigned32, + acSS7M3UAStaticRoutingOPC1 Unsigned32, + acSS7M3UAStaticRoutingOPC2 Unsigned32, + acSS7M3UAStaticRoutingOPC3 Unsigned32, + acSS7M3UAStaticRoutingOPC4 Unsigned32, + acSS7M3UAStaticRoutingLowerCICValue1 Unsigned32, + acSS7M3UAStaticRoutingUpperCICValue1 Unsigned32, + acSS7M3UAStaticRoutingLowerCICValue2 Unsigned32, + acSS7M3UAStaticRoutingUpperCICValue2 Unsigned32, + acSS7M3UAStaticRoutingLowerCICValue3 Unsigned32, + acSS7M3UAStaticRoutingUpperCICValue3 Unsigned32, + acSS7M3UAStaticRoutingLowerCICValue4 Unsigned32, + acSS7M3UAStaticRoutingUpperCICValue4 Unsigned32 + } + + + + acSS7M3UAStaticRoutingIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..100) + MAX-ACCESS not-accessible + STATUS obsolete + DESCRIPTION + "This parameter is used for the Signaling System 7 (SS7) interface +ID index, for a line. +AC INI-Param: M3UAROUTINGCLIST_Index" + ::= {acSS7M3UAStaticRoutingEntry 1} + + + + acSS7M3UAStaticRoutingRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "This parameter is used for the Signaling System 7 (SS7) interface +ID row status, for a line. +AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS" + ::= {acSS7M3UAStaticRoutingEntry 2} + + + + acSS7M3UAStaticRoutingAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + activate(1) +, + deActivate(2) + + } + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "This parameter is used for Signaling System 7 (SS7) SIGTRAN +(Signaling Transport) interface ID management, for actions. +AC INI-Param: SS7_SIG_IF_ID_ACTION" + ::= {acSS7M3UAStaticRoutingEntry 3} + + + + acSS7M3UAStaticRoutingActionResult OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "This parameter is used for Signaling System 7 (SS7) SIGTRAN +(Signaling Transport) interface ID management, for an action's +results. +AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT" + ::= {acSS7M3UAStaticRoutingEntry 4} + + + + acSS7M3UAStaticRoutingOwnerInterfaceGroup OBJECT-TYPE + SYNTAX Unsigned32 (0..30) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup" + ::= {acSS7M3UAStaticRoutingEntry 5} + + + + acSS7M3UAStaticRoutingRC OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_RoutingContext" + ::= {acSS7M3UAStaticRoutingEntry 6} + + + + acSS7M3UAStaticRoutingDestinationPointCode OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode" + ::= {acSS7M3UAStaticRoutingEntry 7} + + + + acSS7M3UAStaticRoutingNetworkAppearence OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence" + ::= {acSS7M3UAStaticRoutingEntry 8} + + + + acSS7M3UAStaticRoutingSeriviceIndicatorList OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList" + ::= {acSS7M3UAStaticRoutingEntry 9} + + + + acSS7M3UAStaticRoutingOPC1 OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_OPC1" + ::= {acSS7M3UAStaticRoutingEntry 10} + + + + acSS7M3UAStaticRoutingOPC2 OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_OPC2" + ::= {acSS7M3UAStaticRoutingEntry 11} + + + + acSS7M3UAStaticRoutingOPC3 OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_OPC3" + ::= {acSS7M3UAStaticRoutingEntry 12} + + + + acSS7M3UAStaticRoutingOPC4 OBJECT-TYPE + SYNTAX Unsigned32 (0..16777215) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_OPC4" + ::= {acSS7M3UAStaticRoutingEntry 13} + + + + acSS7M3UAStaticRoutingLowerCICValue1 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1" + ::= {acSS7M3UAStaticRoutingEntry 14} + + + + acSS7M3UAStaticRoutingUpperCICValue1 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1" + ::= {acSS7M3UAStaticRoutingEntry 15} + + + + acSS7M3UAStaticRoutingLowerCICValue2 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2" + ::= {acSS7M3UAStaticRoutingEntry 16} + + + + acSS7M3UAStaticRoutingUpperCICValue2 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2" + ::= {acSS7M3UAStaticRoutingEntry 17} + + + + acSS7M3UAStaticRoutingLowerCICValue3 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3" + ::= {acSS7M3UAStaticRoutingEntry 18} + + + + acSS7M3UAStaticRoutingUpperCICValue3 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3" + ::= {acSS7M3UAStaticRoutingEntry 19} + + + + acSS7M3UAStaticRoutingLowerCICValue4 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4" + ::= {acSS7M3UAStaticRoutingEntry 20} + + + + acSS7M3UAStaticRoutingUpperCICValue4 OBJECT-TYPE + SYNTAX Unsigned32 (0..65535) + MAX-ACCESS read-create + STATUS obsolete + DESCRIPTION + "Routing Context list - for M3UA use. +Access: Online. +AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4" + ::= {acSS7M3UAStaticRoutingEntry 21} + + + + -- **************************************** + -- acSS7SigTranRoutingContext table declaration + -- **************************************** + acSS7SigTranRoutingContextTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7SigTranRoutingContextEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7SigTran 24} + + + + -- **************************************** + -- acSS7SigTranRoutingContext table entry + -- **************************************** + acSS7SigTranRoutingContextEntry OBJECT-TYPE + SYNTAX AcSS7SigTranRoutingContextEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7SigTranRoutingContextIndex,acSS7SigTranRoutingContextInnerIndex} + ::= {acSS7SigTranRoutingContextTable 1} + + + + -- **************************************** + -- acSS7SigTranRoutingContext TABLE + -- **************************************** + AcSS7SigTranRoutingContextEntry ::= SEQUENCE { + acSS7SigTranRoutingContextIndex Unsigned32, + acSS7SigTranRoutingContextInnerIndex Unsigned32, + acSS7SigTranRoutingContextRowStatus RowStatus, + acSS7SigTranRoutingContextAction INTEGER, + acSS7SigTranRoutingContextActionResult Unsigned32, + acSS7SigTranRoutingContextSnIdx Unsigned32, + acSS7SigTranRoutingContextSpc Integer32, + acSS7SigTranRoutingContextOpc1 Integer32, + acSS7SigTranRoutingContextOpc2 Integer32, + acSS7SigTranRoutingContextOpc3 Integer32, + acSS7SigTranRoutingContextOpc4 Integer32, + acSS7SigTranRoutingContextSi1 Integer32, + acSS7SigTranRoutingContextSi2 Integer32, + acSS7SigTranRoutingContextSi3 Integer32, + acSS7SigTranRoutingContextSi4 Integer32 + } + + + + acSS7SigTranRoutingContextIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..31) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First index field for line. +AC INI-Param: SS7_RC_INDEX" + ::= {acSS7SigTranRoutingContextEntry 1} + + + + acSS7SigTranRoutingContextInnerIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..3) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second index field for line. +AC INI-Param: SS7_RC_INNER_INDEX" + ::= {acSS7SigTranRoutingContextEntry 2} + + + + acSS7SigTranRoutingContextRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS field for line. +AC INI-Param: SS7_RC_ROW_STATUS" + ::= {acSS7SigTranRoutingContextEntry 3} + + + + acSS7SigTranRoutingContextAction OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + activate(1) +, + deActivate(2) + + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Management field for ACTIONS. +AC INI-Param: RCAction" + ::= {acSS7SigTranRoutingContextEntry 4} + + + + acSS7SigTranRoutingContextActionResult OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RCActionRes. +AC INI-Param: SS7_RC_ACTION_RES" + ::= {acSS7SigTranRoutingContextEntry 5} + + + + acSS7SigTranRoutingContextSnIdx OBJECT-TYPE + SYNTAX Unsigned32 (0..5) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context DPC +SN-Index. +Access: Online. +AC INI-Param: SS7_RC_SN_INDEX" + ::= {acSS7SigTranRoutingContextEntry 6} + + + + acSS7SigTranRoutingContextSpc OBJECT-TYPE + SYNTAX Integer32 (-1..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context DPC +parameter. +AC INI-Param: SS7_RC_SPC" + ::= {acSS7SigTranRoutingContextEntry 7} + + + + acSS7SigTranRoutingContextOpc1 OBJECT-TYPE + SYNTAX Integer32 (-1..16777215) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context,First +element of OPC list. +Access: Online. +AC INI-Param: SS7_RC_OPC1" + ::= {acSS7SigTranRoutingContextEntry 8} + + + + acSS7SigTranRoutingContextOpc2 OBJECT-TYPE + SYNTAX Integer32 (-1..16777215) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context,Second +element of OPC list. +Access: Online. +AC INI-Param: SS7_RC_OPC2" + ::= {acSS7SigTranRoutingContextEntry 9} + + + + acSS7SigTranRoutingContextOpc3 OBJECT-TYPE + SYNTAX Integer32 (-1..16777215) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, +Third element of OPC list. +Access: Online. +AC INI-Param: SS7_RC_OPC3" + ::= {acSS7SigTranRoutingContextEntry 10} + + + + acSS7SigTranRoutingContextOpc4 OBJECT-TYPE + SYNTAX Integer32 (-1..16777215) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, +Fourth element of OPC list. +Access: Online. +AC INI-Param: SS7_RC_OPC4" + ::= {acSS7SigTranRoutingContextEntry 11} + + + + acSS7SigTranRoutingContextSi1 OBJECT-TYPE + SYNTAX Integer32 (-1..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, +First element of SI list. +Access: Online. +AC INI-Param: SS7_RC_SI1" + ::= {acSS7SigTranRoutingContextEntry 12} + + + + acSS7SigTranRoutingContextSi2 OBJECT-TYPE + SYNTAX Integer32 (-1..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, + Second element of SI list. +Access: Online. +AC INI-Param: SS7_RC_SI2" + ::= {acSS7SigTranRoutingContextEntry 13} + + + + acSS7SigTranRoutingContextSi3 OBJECT-TYPE + SYNTAX Integer32 (-1..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, + Third element of SI list. +Access: Online. +AC INI-Param: SS7_RC_SI3" + ::= {acSS7SigTranRoutingContextEntry 14} + + + + acSS7SigTranRoutingContextSi4 OBJECT-TYPE + SYNTAX Integer32 (-1..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter is used to specify the M3UA Routing Context, +Fourth element of SI list. +Access: Online. +AC INI-Param: SS7_RC_SI4" + ::= {acSS7SigTranRoutingContextEntry 15} + + + + acSS7Redundancy OBJECT IDENTIFIER ::= {acSS7Configuration 6} + + + acSS7RedundancyCrossLinkTransferType OBJECT-TYPE + SYNTAX INTEGER { + none(0) +, + tcp(2) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the cross-board connection media type for the MTP3 redundancy +feature: +0 = M3BRDCY_CONN_TYPE_NONE +2 = M3BRDCY_CONN_TYPE_TCP. +Access: Offline. +AC INI-Param: SS7MTP3RdcyTransferType" + ::= {acSS7Redundancy 1} + + + + acSS7RedundancyMode OBJECT-TYPE + SYNTAX INTEGER { + disable(0) +, + enable(1) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the MTP3 Signaling redundancy mode: +0 = Disabled +1 = Enabled +. +Access: Offline. +AC INI-Param: SS7MTP3RdcyMode" + ::= {acSS7Redundancy 2} + + + + acSS7RedundancyBoardNum OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the board number for the SS7 (Signaling System 7) MTP3 +redundancy mode. Each board is allocated a unique number. +All boards share a single redundancy table. +Access: Offline. +AC INI-Param: SS7MTP3RdcyBoardNum" + ::= {acSS7Redundancy 3} + + + + acSS7RedundancyCrossLinkTraceAll OBJECT-TYPE + SYNTAX INTEGER { + disable(0) +, + enable(1) + + } + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "When set via INI-file, activates trace output for all X-links +(only when SS7 redundancy is configured). +. +Access: Instant. +AC INI-Param: SS7M3BRdcyXlinkTraceAll" + ::= {acSS7Redundancy 4} + + + + acSS7RedundancyMTP3RdcyTblSyncInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..144000) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the interval between SS7 tables automatic synchronizations, +in minutes. + +0 = no automatic synchronization is activated. +. +Access: Instant. +AC INI-Param: N/A" + ::= {acSS7Redundancy 5} + + + + acSS7RedundancySyncAllBoards OBJECT-TYPE + SYNTAX INTEGER { + noAction(0) +, + sync(1) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Provide SYNC all boards command. +Access: Instant. +AC INI-Param: N/A" + ::= {acSS7Redundancy 6} + + + + acSS7RedundancySyncBoard OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Provide SYNC between this board and another specific board (parameter +is the remote board number). +Access: Instant. +AC INI-Param: N/A" + ::= {acSS7Redundancy 7} + + + + acSS7RedundancyKeepAliveWindow OBJECT-TYPE + SYNTAX Unsigned32 (1..15) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines redundancy X-link keep-alive tolerance window. +(x-link between boards in Signaling System 7 (SS7) MTP3-User +Adaptation Layer redundancy mode). +. +Access: Offline. +AC INI-Param: SS7MTP3RdcyKeepAliveWindow" + ::= {acSS7Redundancy 8} + + + + acSS7RedundancyKeepAliveInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines redundancy X-link keep-alive interval in secs. +(x-link between boards in Signaling System 7 (SS7) MTP3-User +Adaptation Layer redundancy mode). +0 = no keep-alive mechanism is activated. +. +Access: Offline. +AC INI-Param: SS7MTP3RdcyKeepAliveInterval" + ::= {acSS7Redundancy 9} + + + + -- **************************************** + -- acSS7RedundantSN table declaration + -- **************************************** + acSS7RedundantSNTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcSS7RedundantSNEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= {acSS7Redundancy 21} + + + + -- **************************************** + -- acSS7RedundantSN table entry + -- **************************************** + acSS7RedundantSNEntry OBJECT-TYPE + SYNTAX AcSS7RedundantSNEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acSS7RedundantSNBoardIndex,acSS7RedundantSNIndex} + ::= {acSS7RedundantSNTable 1} + + + + -- **************************************** + -- acSS7RedundantSN TABLE + -- **************************************** + AcSS7RedundantSNEntry ::= SEQUENCE { + acSS7RedundantSNBoardIndex Unsigned32, + acSS7RedundantSNIndex Unsigned32, + acSS7RedundantSNRowStatus RowStatus, + acSS7RedundantSNAction Unsigned32, + acSS7RedundantSNActionRes Unsigned32, + acSS7RedundantSNBoardIp IpAddress, + acSS7RedundantSNOPC Unsigned32, + acSS7RedundantSNALCAPOPC Unsigned32 + } + + + + acSS7RedundantSNBoardIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..4) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "First index for a line: board number. +AC INI-Param: SS7_RDCYSN_BOARD_INDEX" + ::= {acSS7RedundantSNEntry 1} + + + + acSS7RedundantSNIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Second index for a line: SN number in the board. +AC INI-Param: SS7_RDCYSN_SN_INDEX" + ::= {acSS7RedundantSNEntry 2} + + + + acSS7RedundantSNRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "ROWSTATUS field for line. +AC INI-Param: SS7_RDCYSN_ROWSTATUS" + ::= {acSS7RedundantSNEntry 3} + + + + acSS7RedundantSNAction OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Management field for ACTION. +AC INI-Param: SS7_RDCYSN_ACTION" + ::= {acSS7RedundantSNEntry 4} + + + + acSS7RedundantSNActionRes OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Management field for ACTION RESULT. +AC INI-Param: SS7_RDCYSN_ACTIONRES" + ::= {acSS7RedundantSNEntry 5} + + + + acSS7RedundantSNBoardIp OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "IP address of the board. +Access: Online. +AC INI-Param: SS7_RDCYSN_BOARD_IP" + ::= {acSS7RedundantSNEntry 6} + + + + acSS7RedundantSNOPC OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Internal point-code of the SN (Signaling Node). +Access: Online. +AC INI-Param: SS7_RDCYSN_OPC" + ::= {acSS7RedundantSNEntry 7} + + + + acSS7RedundantSNALCAPOPC OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Internal point-code of ALCAP instance on a given board. +Access: Online. +AC INI-Param: SS7_RDCYSN_ALCAP_OPC" + ::= {acSS7RedundantSNEntry 8} + + + + acSS7Status OBJECT IDENTIFIER ::= {acSS7 2} + + + acSS7Constants OBJECT IDENTIFIER ::= {acSS7Status 1} + + + acSS7ConstantsNumberOfNodes OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 1} + + + + acSS7ConstantsNumberOfLinks OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 2} + + + + acSS7ConstantsNumberOfLinkSetsPerSN OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 3} + + + + acSS7ConstantsNumberOfLinksPerLinkSet OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 4} + + + + acSS7ConstantsNumberOfRouteSetsPerSN OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 5} + + + + acSS7ConstantsNumberOfRoutesPerRouteSets OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 6} + + + + acSS7ConstantsNumberOfNodeTimerSets OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 7} + + + + acSS7ConstantsNumberOfLinkSetTimerSets OBJECT-TYPE + SYNTAX Unsigned32 (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " +AC INI-Param: N/A" + ::= {acSS7Constants 8} + + + + + +END -- cgit v1.2.3