From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/arris/BCS-IDENT-MIB | 887 +++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 887 insertions(+) create mode 100644 MIBS/arris/BCS-IDENT-MIB (limited to 'MIBS/arris/BCS-IDENT-MIB') diff --git a/MIBS/arris/BCS-IDENT-MIB b/MIBS/arris/BCS-IDENT-MIB new file mode 100644 index 0000000..666da1f --- /dev/null +++ b/MIBS/arris/BCS-IDENT-MIB @@ -0,0 +1,887 @@ +BCS-IDENT-MIB DEFINITIONS ::= BEGIN + +IMPORTS + + DisplayString FROM SNMPv2-TC + OBJECT-TYPE FROM SNMPv2-SMI + MODULE-IDENTITY FROM SNMPv2-SMI; + +gi MODULE-IDENTITY + LAST-UPDATED "201008250000Z" + + ORGANIZATION "Motorola Broadband Home Solutions" + CONTACT-INFO "Motorola Technical Response Center + Inside USA 1-888-944-HELP (1-888-944-4357) + Outside USA 1-215-323-0044 + TRC Hours: + Monday through Friday 8am - 7pm Eastern Standard Time + Saturdays 10am - 5pm Eastern Standard Time" + + DESCRIPTION "The SMIv2 MIB module for the MOTOROLA BCS common ident objects. + The MIB Tree for this is shown below." + + ::= {iso org(3) dod(6) internet(1) private(4) enterprises(1) 1166} + + + giproducts OBJECT IDENTIFIER ::= { gi 1 } + acc4000d OBJECT IDENTIFIER ::= { giproducts 1 } + anicd OBJECT IDENTIFIER ::= { giproducts 2 } + item1000 OBJECT IDENTIFIER ::= { giproducts 4 } + irt1000 OBJECT IDENTIFIER ::= { giproducts 5 } + nc1500 OBJECT IDENTIFIER ::= { giproducts 6 } +-- OM-2000 shares same OID as OM-1000 + om1000 OBJECT IDENTIFIER ::= { giproducts 7 } + im1000 OBJECT IDENTIFIER ::= { giproducts 8 } + mps OBJECT IDENTIFIER ::= { giproducts 9 } + + rpd1000 OBJECT IDENTIFIER ::= { giproducts 10 } + +-- Access Control Processors; TSODAs and other ACPs in various products. + acpStatus OBJECT IDENTIFIER ::= { giproducts 11 } +-- Heartbeat MIB used in the Satellite environment + heartbeat OBJECT IDENTIFIER ::= { giproducts 12 } +-- Entitlement Key Common MIB - used by SDM/SEM + entitlementKey OBJECT IDENTIFIER ::= { giproducts 13 } + + arpd OBJECT IDENTIFIER ::= { giproducts 14 } + svom OBJECT IDENTIFIER ::= { giproducts 15 } + svm OBJECT IDENTIFIER ::= { giproducts 16 } + erm OBJECT IDENTIFIER ::= { giproducts 17 } + +-- GI SURBboard BNH + surfBbnh OBJECT IDENTIFIER ::= { giproducts 18 } + +-- GI SURFboard cable modem + sb2100 OBJECT IDENTIFIER ::= { giproducts 19 } + sb2100D OBJECT IDENTIFIER ::= { giproducts 20 } + sb2000 OBJECT IDENTIFIER ::= { giproducts 21 } + +-- CHS digital video headend equipment +-- + saDANIS OBJECT IDENTIFIER ::= { giproducts 30 } + apex OBJECT IDENTIFIER ::= { giproducts 31 } + rem OBJECT IDENTIFIER ::= { giproducts 32 } + mpe OBJECT IDENTIFIER ::= { giproducts 33 } + spe OBJECT IDENTIFIER ::= { giproducts 34 } + ne2000 OBJECT IDENTIFIER ::= { giproducts 35 } + apex1500 OBJECT IDENTIFIER ::= { giproducts 36 } + agb OBJECT IDENTIFIER ::= { giproducts 37 } + ne2500 OBJECT IDENTIFIER ::= { giproducts 38 } +-- + hdd2000 OBJECT IDENTIFIER ::= { giproducts 40 } +-- + merlin OBJECT IDENTIFIER ::= { giproducts 50 } +-- + rsr OBJECT IDENTIFIER ::= { giproducts 60 } + gsrm OBJECT IDENTIFIER ::= { giproducts 61 } + gom OBJECT IDENTIFIER ::= { giproducts 62 } + b3 OBJECT IDENTIFIER ::= { giproducts 63 } + adm OBJECT IDENTIFIER ::= { giproducts 64 } + +-- San Diego Headend devices + + sem OBJECT IDENTIFIER ::= { giproducts 70 } + ecmg OBJECT IDENTIFIER ::= { giproducts 71 } + bsiAdapter OBJECT IDENTIFIER ::= { giproducts 72 } + oles OBJECT IDENTIFIER ::= { giproducts 73 } + ne OBJECT IDENTIFIER ::= { giproducts 74 } + tmxCommTrap OBJECT IDENTIFIER ::= { giproducts 75 } + drmenginekskdc OBJECT IDENTIFIER ::= { giproducts 76 } + drmenginerte OBJECT IDENTIFIER ::= { giproducts 77 } + drmengineecmg OBJECT IDENTIFIER ::= { giproducts 78 } + drmengineskgpkg OBJECT IDENTIFIER ::= { giproducts 79 } + tmx OBJECT IDENTIFIER ::= { giproducts 80 } + prs OBJECT IDENTIFIER ::= { giproducts 81 } + se2000 OBJECT IDENTIFIER ::= { giproducts 82 } + dem OBJECT IDENTIFIER ::= { giproducts 83 } + ncs OBJECT IDENTIFIER ::= { giproducts 84 } + ucs OBJECT IDENTIFIER ::= { giproducts 85 } + lmm OBJECT IDENTIFIER ::= { giproducts 86 } + se4000 OBJECT IDENTIFIER ::= { giproducts 87 } + rc OBJECT IDENTIFIER ::= { giproducts 88 } + +-- +-- Element Management System Range +-- + netSentry OBJECT IDENTIFIER ::= { giproducts 99 } + sdm OBJECT IDENTIFIER ::= { giproducts 100 } + hfcEms OBJECT IDENTIFIER ::= { giproducts 101 } + bnc OBJECT IDENTIFIER ::= { giproducts 102 } + drmenginecm OBJECT IDENTIFIER ::= { giproducts 103 } + stdc OBJECT IDENTIFIER ::= { giproducts 104 } + tview OBJECT IDENTIFIER ::= { giproducts 105 } +-- +-- OIDS 106 thru 110 reserved for other EMS +-- +-- +-- +-- OIDS 150 thru 225 reserved for TNS/NIS +-- + ponOa OBJECT IDENTIFIER ::= { giproducts 150 } + mwtea200 OBJECT IDENTIFIER ::= { giproducts 151 } + + bti OBJECT IDENTIFIER ::= { giproducts 200 } + rfModMIB OBJECT IDENTIFIER ::= { giproducts 201 } + btiIntMIB OBJECT IDENTIFIER ::= { giproducts 202 } + sg4000 OBJECT IDENTIFIER ::= { giproducts 203 } + + ponEm870 OBJECT IDENTIFIER ::= { giproducts 210 } +-- +-- OIDS 250 thru 290 reserved for TAS +-- + rpa OBJECT IDENTIFIER ::= { giproducts 250 } + rpc OBJECT IDENTIFIER ::= { giproducts 251 } +-- +-- OIDS 300 thru 310 reserved for ASTBs +-- + dct5000 OBJECT IDENTIFIER ::= { giproducts 300 } + dct5100 OBJECT IDENTIFIER ::= { giproducts 301 } + dct5200 OBJECT IDENTIFIER ::= { giproducts 302 } +-- +-- OIDS 314 thru 320 reserved for other CPEs +-- + edfaMIB OBJECT IDENTIFIER ::= { giproducts 311 } + corvusMIB OBJECT IDENTIFIER ::= { giproducts 312 } + oa600 OBJECT IDENTIFIER ::= { giproducts 313 } +-- +-- Range 321-330 reserved for DSRs +-- + dsr350f OBJECT IDENTIFIER ::= { giproducts 321 } + + radd6000 OBJECT IDENTIFIER ::= { giproducts 400 } + cs1000 OBJECT IDENTIFIER ::= { giproducts 401 } + kls OBJECT IDENTIFIER ::= { giproducts 402 } + dac6000 OBJECT IDENTIFIER ::= { giproducts 403 } + sdi OBJECT IDENTIFIER ::= { giproducts 404 } + cpms OBJECT IDENTIFIER ::= { giproducts 405 } + ap OBJECT IDENTIFIER ::= { giproducts 406 } + ps OBJECT IDENTIFIER ::= { giproducts 407 } +-- +-- Range 350-359 reserved for Cable Cards +-- + cableCard OBJECT IDENTIFIER ::= { giproducts 350 } +-- +-- The following branch identifies the BCS/IPNS Devices MIB. +-- + motoIPNSprodID OBJECT IDENTIFIER ::= { giproducts 450 } +-- +-- Range 500-510 reserved for Simulcrypt +-- +-- +-- Range 600-650 reserved for IRDs +-- + ird4500x OBJECT IDENTIFIER ::= { giproducts 610 } + ird4520x OBJECT IDENTIFIER ::= { giproducts 620 } + + + giproxies OBJECT IDENTIFIER ::= { gi 3 } + + gicommon OBJECT IDENTIFIER ::= { gi 4 } + identity OBJECT IDENTIFIER ::= { gicommon 1 } + state OBJECT IDENTIFIER ::= { gicommon 2 } + traps OBJECT IDENTIFIER ::= { gicommon 3 } + logs OBJECT IDENTIFIER ::= { gicommon 4 } +-- +-- nlsbbn OBJECT IDENTIFIER ::= { gi 5 } +-- added to create new path for gx2 hfc common and device mibs + motproxies OBJECT IDENTIFIER ::= { gi 6 } + +-- +-- The following is the SMIv2 COMMON MIB branch +-- + bcs OBJECT IDENTIFIER ::= { gi 7 } + bcsIdent OBJECT IDENTIFIER ::= { bcs 1 } +-- bcsState OBJECT IDENTIFIER ::= { bcs 2 } +-- bcsTraps OBJECT IDENTIFIER ::= { bcs 3 } + bcsLogs OBJECT IDENTIFIER ::= { bcs 4 } + +-- dms OBJECT IDENTIFIER ::= { bcs 5 } +-- +-- New OID for SMIv2 of ACP MIB +-- +-- bcs_acp OBJECT IDENTIFIER ::= { bcs 6 } +-- +-- bcs OID 7 - 10 reserved for Simulcrypt +-- + bcsSimulcryptScs OBJECT IDENTIFIER ::= { bcs 7 } + bcsSimulcryptMux OBJECT IDENTIFIER ::= { bcs 8 } + bcsSimulcrypt OBJECT IDENTIFIER ::= { bcs 9 } + +-- bcs OID 11 - 20 reserved for common BCS infrastructure MIBs +-- + bcsDatabase OBJECT IDENTIFIER ::= { bcs 11 } + bcsRedundancy OBJECT IDENTIFIER ::= { bcs 12 } + + bcsMsgGeneration OBJECT IDENTIFIER ::= { bcs 21 } +-- +-- Reserved for TNS + mea OBJECT IDENTIFIER ::= { gi 8 } +-- +-- Reserved for common Addressable Control MIBs + addressablecontrol OBJECT IDENTIFIER ::= { gi 9 } + acCommon OBJECT IDENTIFIER ::= { addressablecontrol 1 } + acSecurity OBJECT IDENTIFIER ::= { addressablecontrol 2 } + acServices OBJECT IDENTIFIER ::= { addressablecontrol 3 } + acBsi OBJECT IDENTIFIER ::= { addressablecontrol 4 } + acOperations OBJECT IDENTIFIER ::= { addressablecontrol 5 } + acTopology OBJECT IDENTIFIER ::= { addressablecontrol 6 } + +-- +-- Reserved for common CHS internal MIBs + chsInternal OBJECT IDENTIFIER ::= { gi 10 } + emLogin OBJECT IDENTIFIER ::= { chsInternal 1 } + radiusClient OBJECT IDENTIFIER ::= { chsInternal 2 } + +-- Need to explicitly define EntryStatus since most do not recognize +-- the version 1 format. +EntryStatus ::= INTEGER + { valid(1), + createRequest(2), + underCreation(3), + invalid(4) + } + + -- groups in the GI-IDENT MIB + +-- MIB Tree +-- +-- The following diagram defining the objects in this MIB is for +-- reference purposes only. +-- +-- bcs +-- | +-- +..bcsIdent +-- | | +-- | +..identSerialNumber +-- | | +-- | +..identChassisNumber +-- | | +-- | +..identIfIndex +-- | | +-- | +..identHardwareVersion +-- | | +-- | +..identHardwareFeatures +-- | | +-- | +..identInventoryCode +-- | | +-- | +..identSoftwareVersion +-- | | +-- | +..identLocationArea +-- | | +-- | +..identLocationRack +-- | | +-- | +..identLocationShelf +-- | | +-- | +..identMIBVersion +-- | | +-- | +..identAgentVersion +-- | | +-- | +..identCommand +-- | | +-- | +..identIfExtensionTable +-- | | | +-- | | +..identIfExtensionEntry +-- | | | +-- | | +..identIfExtensionIndex +-- | | | +-- | | +..identIfSerialNumber +-- | | | +-- | | +..identIfHardwareVersion +-- | | | +-- | | +..identIfHardwareFeatures +-- | | | +-- | | +..identIfInventoryCode +-- | | | +-- | | +..identIfFirmwareVersion1 +-- | | | +-- | | +..identIfFirmwareVersion2 +-- | | | +-- | | +..identIfFirmwareVersion3 +-- | | | +-- | | +..identIfFirmwareVersion4 +-- | | | +-- | | +..identIfSlotId +-- | | | +-- | | +..identIfCommand +-- | | | +-- | | +..identIfAdministrativeState +-- | | | +-- | | +..identIfOperationalState +-- | | | +-- | | +..identIfAlarmStatus +-- | | | +-- | | +..identIfAvailabilityStatus +-- | | | +-- | | +..identIfSpecific +-- | | | +-- | | +..identIfEntryStatus +-- | | +-- | +..identUnitModel + + + +-- The Identification Group. + +-- This group of objects contains the identification of the software +-- and hardware for a specific unit. + + identSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains the serial number of the unit. There is no + specification of the internal format of the serial number. + The serial number is entered into either permanent or non- + volatile memory of the unit at the time of manufacture. + Note - the unit itself supplies the serial number." + REFERENCE " -- " + ::= { bcsIdent 1 } + + identChassisNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains the chassis number of the unit. This is + applicable only to a limited number of products, + currently, only the ITEM-1000. For products for which + this is not applicable, this will be a null object. + There is no specification of the internal format of + the chassis number. The means by which any product + determines its chassis number is to be determined by + each individual product." + REFERENCE " -- " + ::= { bcsIdent 2 } + + + identIfIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains the IfIndex of the OAM&P port." + REFERENCE " -- " + DEFVAL { 2147483647 } + ::= { bcsIdent 3 } + + + identHardwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains a display string that defines the hardware + version of this particular unit. There is no specification + of the internal format of the hardware version. The + hardware version is entered into the either permanent or + non-volatile memory of the unit at the time of + manufacture." + REFERENCE " -- " + ::= { bcsIdent 4 } + + + identHardwareFeatures OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains a display string that defines the features + of this particular unit. There is no specification of the + internal format of the hardware features. The hardware + features is entered into the either permanent or + non-volatile memory of the unit at the time of + manufacture." + REFERENCE " -- " + ::= { bcsIdent 5 } + + + identInventoryCode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This contains a display string that defines the inventory + code for this unit. + Once an inventory code has been set, it should be kept in + non-volatile memory. The unit should only allow this object + to be set when it is in the 'configuration' mode. There is + no specification of the internal format of the inventory + Code." + REFERENCE " -- " + ::= { bcsIdent 6 } + + + identSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains a display string that defines the current + version of the software for this unit. The format of the + software version is a fully qualified directory name. This + value is received by a unit as within a BOOTP response from + the BOOTP server. It is available to the network manager + for applications that track the installed software. Once + the software version has been set, it should be kept in + non-volatile memory." + REFERENCE " -- " + ::= { bcsIdent 7 } + + + identLocationArea OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is different from the MIB II sysLocation variable as it + contains only the location area and does not describe the + precise location. + This contains a display string that defines the area in + which the unit is installed. Location is defined by a set + of three objects: 'Area', 'Rack', and 'Shelf'. These + location objects cannot be determined by the unit itself, + but can only be determined by the network manager. It is + available to the unit for display on a front panel. Display + of the location on the front panel is useful in validating + the configuration established by the network manager. The + unit should only allow this object to be set when it is in + the 'configuration' mode. Once the Location Area has been + set, it should be kept in non-volatile memory." + REFERENCE " -- " + ::= { bcsIdent 8 } + + + identLocationRack OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This contains a display string that defines the rack in + which the unit is installed. Location is defined by a set + of three objects: 'Area', 'Rack', and 'Shelf'. These + location objects cannot be determined by the unit itself, + but can only be determined by the network manager. It is + available to the unit for display on a front panel. Display + of the location on the front panel is useful in validating + the configuration established by the network manager. The + unit should only allow this object to be set when it is in + the 'configuration' mode. Once the Location Area has been + set, it should be kept in non-volatile memory." + REFERENCE " -- " + ::= { bcsIdent 9 } + + + identLocationShelf OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This contains a display string that defines the shelf in + which the unit is installed. Location is defined by a set + of three objects: 'Area', 'Rack', and 'Shelf'. These + location objects cannot be determined by the unit itself, + but can only be determined by the network manager. It is + available to the unit for display on a front panel. Display + of the location on the front panel is useful in validating + the configuration established by the network manager. The + unit should only allow this object to be set when it is in + the 'configuration' mode. Once the Location Area has been + set, it should be kept in non-volatile memory." + REFERENCE " -- " + ::= { bcsIdent 10 } + + + + identMIBVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The version number of this MIB." + REFERENCE " -- " + ::= { bcsIdent 11 } + + + identAgentVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version number of the Agent." + REFERENCE " -- " + ::= { bcsIdent 12 } + + + identCommand OBJECT-TYPE + SYNTAX INTEGER + { + restart(1), + currentlyRestarting(2), + unspecified(3), + purgeAndRestart(4), + currentlyPurgingAndRestarting(5), + purgeNvramAndRestart(6), + currentlyPurgingNvramAndRestarting(7) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is the command to be executed by the resource + managed by the agent. + The value unspecified is always returned on SNMP + Get/GetNext while the resource is running. If the + restart(1) command is given, currentlyRestarting(2) + is returned while the resource is preparing to + restart (reboot)." + REFERENCE " -- " + ::= { bcsIdent 13 } + + + identIfExtensionTable OBJECT-TYPE + SYNTAX SEQUENCE OF IdentIfExtensionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains extensions to the MIB II ifTable which contains + the definitions of all interfaces. An ifTable entry may be a board + or just a port on a board. Any ifTable entry can have an extension + in the identIfExtensionTable. The corrsponding entry in that table + will have the identIfIndex = ifIndex. Within the ifTable the presence + of such an entry is indicated by setting the variable ifSpecific + to the OBJECT IDENTIFIER value of identIfExtensionTable. Otherwise + iFSpecific is set to {0 0}. + The ifType - other - is used for all board types not envisoned by + MIB II." + REFERENCE " -- " + ::= { bcsIdent 14 } + + + identIfExtensionEntry OBJECT-TYPE + SYNTAX IdentIfExtensionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry (conceptual row) in the Board Table." + REFERENCE " -- " + INDEX { identIfExtensionIndex } + ::= { identIfExtensionTable 1 } + + + + IdentIfExtensionEntry ::= SEQUENCE + { + identIfExtensionIndex INTEGER, + identIfSerialNumber DisplayString, + identIfHardwareVersion DisplayString, + identIfHardwareFeatures DisplayString, + identIfInventoryCode DisplayString, + identIfFirmwareVersion1 DisplayString, + identIfFirmwareVersion2 DisplayString, + identIfFirmwareVersion3 DisplayString, + identIfFirmwareVersion4 DisplayString, + identIfSlotId INTEGER, + identIfCommand INTEGER, + identIfAdministrativeState INTEGER, + identIfOperationalState INTEGER, + identIfAlarmStatus INTEGER, + identIfAvailabilityStatus INTEGER, + identIfSpecific OBJECT IDENTIFIER, + identIfEntryStatus EntryStatus + } + + + identIfExtensionIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Same value as ifIndex of MIB II for the same board." + REFERENCE " -- " + DEFVAL { 2147483647 } + ::= { identIfExtensionEntry 1 } + + + identIfSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains the serial number of the board. There is no + specification of the internal format of the serial number. + The serial number is entered into either permanent or + non-volatile memory of the unit at the time of manufacture. + Note - the unit itself supplies the serial number." + REFERENCE " -- " + ::= { identIfExtensionEntry 2 } + + + + identIfHardwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains a display string that defines the version + of this particular board. There is no specification of the + internal format of the hardware version. The hardware + version is entered into the either permanent or + non-volatile memory of the unit at the time of + manufacture." + REFERENCE " -- " + ::= { identIfExtensionEntry 3 } + + + identIfHardwareFeatures OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains a display string that defines the features of + this particular board. There is no specification of the + internal format of the hardware features. The hardware + features is entered into the either permanent or + non-volatile memory of the unit at the time of manufacture." + REFERENCE " -- " + ::= { identIfExtensionEntry 4 } + + + identIfInventoryCode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This contains a display string that defines the inventory + code for this board. This is an optional value; if there is + no inventory code, The unit will respond with a null string. + Once an inventory code has been set, it should be kept in + non-volatile memory. The unit should only allow this object + to be set when it is in the 'configuration' mode. There is + no specification of the internal format of the inventory + Code." + REFERENCE " -- " + ::= { identIfExtensionEntry 5 } + + + + identIfFirmwareVersion1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Within a product, there may be several identifiers of such + firmware, boot proms, kernel versions, flash versions, etc. + This field (and the 3 that follow) are used to hold the + identification of these items. These values must be entered + into the board at the time of manufacturing. Unused fields + are reported as null values. These fields are available to + the network manager for applications that keep track of the + firmware related identification. There is no specification + of the internal format of firmware version identifiers." + REFERENCE " -- " + ::= { identIfExtensionEntry 6 } + + + identIfFirmwareVersion2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware related identification field # 2." + REFERENCE " -- " + ::= { identIfExtensionEntry 7 } + + + identIfFirmwareVersion3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware related identification field # 3." + REFERENCE " -- " + ::= { identIfExtensionEntry 8 } + + + identIfFirmwareVersion4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware related identification field # 4" + REFERENCE " -- " + ::= { identIfExtensionEntry 9 } + + + identIfSlotId OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This variable identifies the board slot." + REFERENCE " -- " + DEFVAL { 2147483647 } + ::= { identIfExtensionEntry 10 } + + + identIfCommand OBJECT-TYPE + SYNTAX INTEGER + { + unspecified(1), + reset(2), + restart(3), + halt(4) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is the command to be executed by the resource + managed by the agent. + The value unspecified(10 is always returned on SNMP + Get/GetNext while the other values are set by the manager + and executed by the resource." + REFERENCE " -- " + ::= { identIfExtensionEntry 11 } + + + identIfAdministrativeState OBJECT-TYPE + SYNTAX INTEGER + { + locked(1), + unlocked(2), + shuttingDown(3) + } + + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The current Adminsitrative state of the interface as defined in + ISO/IEC 10164-2." + REFERENCE " -- " + ::= { identIfExtensionEntry 12 } + + + identIfOperationalState OBJECT-TYPE + SYNTAX INTEGER + { + enabled(1), + disabled(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The current Operational state of the interface as defined in + ISO/IEC 10164-2" + REFERENCE " -- " + ::= { identIfExtensionEntry 13 } + + + identIfAlarmStatus OBJECT-TYPE + SYNTAX INTEGER + { + underRepair(1), + critical(2), + major(3), + minor(4), + alarmOutstanding(5), + idle(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This object defines the Alarm status of the interface + as defined in ISO/IEC 10164-2 and state-machine" + REFERENCE " -- " + ::= { identIfExtensionEntry 14 } + + + identIfAvailabilityStatus OBJECT-TYPE + SYNTAX INTEGER + { + inTest(1), + failed(2), + powerOff(3), + offLine(4), + offDuty(5), + dependency(6), + degraded(7), + notInstalled(8), + logFull(9), + available(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This object controls the Availability status of the interface + as defined in ISO/IEC 10164-2 and state-machine" + REFERENCE " -- " + ::= { identIfExtensionEntry 15 } + + + identIfSpecific OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The object identifier of a board type specific + extension to the ifTable if necessary. Otherwise, + identIfSpecific is set to {0 0}." + REFERENCE " -- " + ::= { identIfExtensionEntry 16 } + + + identIfEntryStatus OBJECT-TYPE + SYNTAX EntryStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to create, delete or + modify a row in this table. To create a + a new network element, this object is initially + set to 'createRequest'. After completion of the + configuration of the new entry, the manager + must set the appropriate instance of this object + to the value valid(1) or aborts, setting this object + to invalid(4). This object must not be set to + 'active' unless the following columnar objects + exist in this row: + identIfExtensionIndex + identIfSerialNumber + identIfHardwareVersion + identIfInventoryCode + identIfFirmwareVersion1 + identIfSpecific + To delete an existing entry in this table, + the manager must set the appropriate + instance of this object to the value invalid(4). + Creation of an instance of this object has the + effect of creating the supplemental object instances + to complete the conceptual row. An existing instance + of this entry cannot be created. If circumstances + occur which cause an entry to become invalid, the + agent modifies the value of the appropriate instance + of this object to invalid(4). Whenever, the value of + this object for a particular entry becomes + invalid(4), the conceptual row for that instance may + be removed from the table at any time, either + immediately or subsequently." + DEFVAL { valid } + ::= { identIfExtensionEntry 17 } + + + + identUnitModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This contains the model of the product. For example, + the ITEM-1000 would contain 'ITEM1000'. " + REFERENCE " -- " + ::= { bcsIdent 15 } + + + + +END \ No newline at end of file -- cgit v1.2.3