From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/accedian/ACD-SFP-MIB | 1182 +++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 1182 insertions(+) create mode 100644 MIBS/accedian/ACD-SFP-MIB (limited to 'MIBS/accedian/ACD-SFP-MIB') diff --git a/MIBS/accedian/ACD-SFP-MIB b/MIBS/accedian/ACD-SFP-MIB new file mode 100644 index 0000000..d8cdf4a --- /dev/null +++ b/MIBS/accedian/ACD-SFP-MIB @@ -0,0 +1,1182 @@ +-- +-- Accedian Enterprise Specific MIB +-- +-- Copyright (c) 2005-2010, Accedian Networks, Inc. +-- All rights reserved. +-- +-- The contents of this document is subject to change without notice. +-- + + +ACD-SFP-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + Integer32, Unsigned32 + FROM SNMPv2-SMI + DisplayString, TruthValue + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF + acdMibs + FROM ACCEDIAN-SMI; + +acdSfp MODULE-IDENTITY + + LAST-UPDATED "201011100100Z" + ORGANIZATION "Accedian Networks, Inc." + CONTACT-INFO + "Accedian Technical Assistance Center + Accedian Networks, Inc. + 4878 Levy, suite 202 + Saint-Laurent, Quebec Canada H4R 2P1 + E-mail: support@accedian.com" + DESCRIPTION + "The SFPs database for this Accedian Networks device." + + REVISION "201011100100Z" -- 10 November 2010 + DESCRIPTION + "Add compliance section." + + REVISION "200804220100Z" -- 22 April 2008 + DESCRIPTION + "Add acdSfpInfoIdType, acdSfpInfoExtIdType and acdSfpInfoTransCode support." + + REVISION "200608060100Z" -- 6 Aug 2006 + DESCRIPTION + "Initial version of MIB module ACD-SFP-MIB." + + ::= { acdMibs 4 } + +acdSfpNotifications OBJECT IDENTIFIER ::= { acdSfp 5 } +acdSfpMIBObjects OBJECT IDENTIFIER ::= { acdSfp 6 } +acdSfpConformance OBJECT IDENTIFIER ::= { acdSfp 7 } + +----------------------------------------------------------------------- + -- The information SFP table + -- This table contains all SFP Info. +--------------------------------------------------------------------------- + +acdSfpInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcdSfpInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of all SFP info" + ::= { acdSfp 1 } + +acdSfpInfoEntry OBJECT-TYPE + SYNTAX AcdSfpInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a part of the content of the SFP's 0xA0 EEPROM" + INDEX { acdSfpInfoID } + ::= { acdSfpInfoTable 1 } + + +AcdSfpInfoEntry ::= SEQUENCE { + acdSfpInfoID Unsigned32, + acdSfpInfoConnIdx Unsigned32, + acdSfpInfoConnType INTEGER, + acdSfpInfoVendor DisplayString, + acdSfpInfoVendorOui DisplayString, + acdSfpInfoVendorPn DisplayString, + acdSfpInfoVendorRev DisplayString, + acdSfpInfoWavelength Unsigned32, + acdSfpInfoSerialNum DisplayString, + acdSfpInfoYear Unsigned32, + acdSfpInfoMonth Unsigned32, + acdSfpInfoDay Unsigned32, + acdSfpInfoLot Unsigned32, + acdSfpInfoRev8472 INTEGER, + acdSfpInfoPresent TruthValue, + acdSfpInfoDiag TruthValue, + acdSfpInfoInternal TruthValue, + acdSfpInfoAlm TruthValue, + acdSfpInfoIdType Unsigned32, + acdSfpInfoExtIdType Unsigned32, + acdSfpInfoTransCode DisplayString +} + +acdSfpInfoID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique value for each SFP. Its value ranges from 1 to + MAXINT (4 bytes). " + ::= { acdSfpInfoEntry 1 } + +acdSfpInfoConnIdx OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the connector index on the box. The index + is assigned form left to rigth starting with 1." + ::= { acdSfpInfoEntry 2 } + +acdSfpInfoConnType OBJECT-TYPE + SYNTAX INTEGER { + sfpSC(1), + sfpFC1COPPER(2), + sfpFC2COPPER(3), + sfpBNC(4), + sfpFCCOAX(5), + sfpFIBERJACK(6), + sfpLC(7), + sfpMTRJ(8), + sfpMU(9), + sfpSG(10), + sfpPIGTAIL(11), + sfpHSSDCII(32), + sfpCOPPERPIGTAIL(33) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The connector value indicates the external optical or electrical + cable connector provided as the media interface." + ::= { acdSfpInfoEntry 3 } + +acdSfpInfoVendor OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor name is a 16 character field that contains ASCII + characters, left-aligned and padded on the right with ASCII + spaces (20h). The vendor name shall be the full name of the + corporation, a commonly accepted abbreviation of the name of + the corporation, the SCSI company code for the corporation, + or the stock exchange code for the corporation. At least one + of the vendor name or the vendor OUI fields shall contain + valid serial data." + ::= { acdSfpInfoEntry 4 } + +acdSfpInfoVendorOui OBJECT-TYPE + SYNTAX DisplayString (SIZE (3)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor organizationally unique identifier field (vendor OUI) + is a 3-byte field that contains the IEEE Company Identifier for + the vendor. A value of all zero in the 3-byte field indicates + that the Vendor OUI is unspecified." + ::= { acdSfpInfoEntry 5 } + +acdSfpInfoVendorPn OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor part number (vendor PN) is a 16-byte field that + contains ASCII characters, leftaligned and padded on the + right with ASCII spaces (20h), defining the vendor's part + number or product name. A value of all zero in the 16-byte + field indicates that the vendor PN is unspecified." + ::= { acdSfpInfoEntry 6 } + +acdSfpInfoVendorRev OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor revision number (vendor rev) is a 4-byte field that + contains ASCII characters, leftaligned and padded on the right + with ASCII spaces (20h), defining the vendor's product revision + number. A value of all zero in the 4-byte field indicates that + the vendor PN is unspecified." + ::= { acdSfpInfoEntry 7 } + +acdSfpInfoWavelength OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nominal transmitter output wavelength at room temperature. 16 bit + value with byte 60 as high order byte and byte 61 as low order + byte. The laser wavelength is equal to the 16 bit integer + value in nm. This field allows the user to read the laser + wavelength directly, so it is not necessary to infer it from the + transceiver Code for Electronic Compatibility." + ::= { acdSfpInfoEntry 8 } + +acdSfpInfoSerialNum OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor serial number (vendor SN) is a 16 character field that + contains ASCII characters, left-aligned and padded on the right + with ASCII spaces (20h), defining the vendor's serial number for + the transceiver. A value of all zero in the 16-byte field indicates + that the vendor PN is unspecified." + ::= { acdSfpInfoEntry 9 } + +acdSfpInfoYear OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the year of manufacturing." + ::= { acdSfpInfoEntry 10 } + +acdSfpInfoMonth OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the month of manufacturing." + ::= { acdSfpInfoEntry 11 } + +acdSfpInfoDay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the day of manufacturing." + ::= { acdSfpInfoEntry 12 } + +acdSfpInfoLot OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the Lot number of manufacturing." + ::= { acdSfpInfoEntry 13 } + + +acdSfpInfoRev8472 OBJECT-TYPE + SYNTAX INTEGER { + undefined(0), + rev93(1), + rev94(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate to which revision this SFP is compatible." + ::= { acdSfpInfoEntry 14 } + +acdSfpInfoPresent OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the SFP is present or not." + ::= { acdSfpInfoEntry 15 } + +acdSfpInfoDiag OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the SFP supports Digital Diagnostics." + ::= { acdSfpInfoEntry 16 } + +acdSfpInfoInternal OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the SFP supports internal calibration. If + externally calibrated, the measurements are raw A/D values and must + be converted to real world units using calibration constants + stored in EEPROM locations 56 to 95 at 2 wire serial bus address + A2h. Calibration is valid over vendor specified operating + temperature and voltage. Alarm and warning threshold values + should be interpreted in the same manner as real time 16 bit data." + ::= { acdSfpInfoEntry 17 } + +acdSfpInfoAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the SFP supports Alarm and warning + thresholds for the Digital Diagnostics." + ::= { acdSfpInfoEntry 18 } + +acdSfpInfoIdType OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identifier value specifies the physical device described by + the two-wire interface information. This value shall be included + in the two-wire interface data (see SFF-8472 for details)." + ::= { acdSfpInfoEntry 19 } + +acdSfpInfoExtIdType OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The extended identifier value provides additional information + about the transceiver. The field should be set to 04h for all SFP + modules indicating two-wire interface ID module definition (see + SFF-8472 for details)." + ::= { acdSfpInfoEntry 20 } + +acdSfpInfoTransCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The following bit significant indicators define the electronic + or optical interfaces that are supported by the transceiver. At + least one bit shall be set in this field (see SFF-8472 for details)." + ::= { acdSfpInfoEntry 21 } + +----------------------------------------------------------------------- + -- The Digital Diagnostics SFP table + -- This table contains all SFP Digital Diagnostics. +--------------------------------------------------------------------------- + +acdSfpDiagTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcdSfpDiagEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of all SFP Digital Diagnostics" + ::= { acdSfp 2 } + +acdSfpDiagEntry OBJECT-TYPE + SYNTAX AcdSfpDiagEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a part the content of the SFP's 0xA0 EEPROM" + INDEX { acdSfpDiagID } + ::= { acdSfpDiagTable 1 } + + +AcdSfpDiagEntry ::= SEQUENCE { + acdSfpDiagID Unsigned32, + acdSfpDiagConnIdx Unsigned32, + acdSfpDiagTemp Integer32, + acdSfpDiagVcc Unsigned32, + acdSfpDiagLbc Unsigned32, + acdSfpDiagTxPwr Unsigned32, + acdSfpDiagRxPwr Unsigned32, + acdSfpDiagTxPwrdBm DisplayString, + acdSfpDiagRxPwrdBm DisplayString +} + +acdSfpDiagID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique value for each SFP. Its value ranges from 1 to + MAXINT (4 bytes). " + ::= { acdSfpDiagEntry 1 } + +acdSfpDiagConnIdx OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the connector index on the box. The index + is assigned form left to rigth starting with 1." + ::= { acdSfpDiagEntry 2 } + +acdSfpDiagTemp OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Internally measured transceiver temperature. Represented as a + 16 bit signed twos complement value in degrees Celsius, yielding + a total range of -128C to +128C." + ::= { acdSfpDiagEntry 3 } + +acdSfpDiagVcc OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Internally measured transceiver supply voltage. Represented as + a 16 bit unsigned integer with the voltage defined as the full + 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, + yielding a total range of 0 to +6.55 Volts." + ::= { acdSfpDiagEntry 4 } + +acdSfpDiagLbc OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured TX bias current in micro-Amps yielding a total range of + 0 to 131 mA." + ::= { acdSfpDiagEntry 5 } + +acdSfpDiagTxPwr OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured TX output power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpDiagEntry 6 } + +acdSfpDiagRxPwr OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured Rx input power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpDiagEntry 7 } + +acdSfpDiagTxPwrdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured TX output power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpDiagEntry 8 } + +acdSfpDiagRxPwrdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured Rx input power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpDiagEntry 9 } + +----------------------------------------------------------------------- + -- The Alarm and Warning Thresholds SFP table + -- This table contains all SFP Alarm and Warning Thresholds. +--------------------------------------------------------------------------- + +acdSfpThreshTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcdSfpThreshEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of all SFP Alarm and Warning Thresholds" + ::= { acdSfp 3 } + +acdSfpThreshEntry OBJECT-TYPE + SYNTAX AcdSfpThreshEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This is a part the content of the SFP's 0xA0 EEPROM" + INDEX { acdSfpThreshID } + ::= { acdSfpThreshTable 1 } + + +AcdSfpThreshEntry ::= SEQUENCE { + acdSfpThreshID Unsigned32, + acdSfpThreshConnIdx Unsigned32, + acdSfpThreshTempHighAlm Integer32, + acdSfpThreshTempLowAlm Integer32, + acdSfpThreshTempHighWarn Integer32, + acdSfpThreshTempLowWarn Integer32, + acdSfpThreshVccHighAlm Unsigned32, + acdSfpThreshVccLowAlm Unsigned32, + acdSfpThreshVccHighWarn Unsigned32, + acdSfpThreshVccLowWarn Unsigned32, + acdSfpThreshLbcHighAlm Unsigned32, + acdSfpThreshLbcLowAlm Unsigned32, + acdSfpThreshLbcHighWarn Unsigned32, + acdSfpThreshLbcLowWarn Unsigned32, + acdSfpThreshTxPwrHighAlm Unsigned32, + acdSfpThreshTxPwrLowAlm Unsigned32, + acdSfpThreshTxPwrHighWarn Unsigned32, + acdSfpThreshTxPwrLowWarn Unsigned32, + acdSfpThreshRxPwrHighAlm Unsigned32, + acdSfpThreshRxPwrLowAlm Unsigned32, + acdSfpThreshRxPwrHighWarn Unsigned32, + acdSfpThreshRxPwrLowWarn Unsigned32, + acdSfpThreshTxPwrHighAlmdBm DisplayString, + acdSfpThreshTxPwrLowAlmdBm DisplayString, + acdSfpThreshTxPwrHighWarndBm DisplayString, + acdSfpThreshTxPwrLowWarndBm DisplayString, + acdSfpThreshRxPwrHighAlmdBm DisplayString, + acdSfpThreshRxPwrLowAlmdBm DisplayString, + acdSfpThreshRxPwrHighWarndBm DisplayString, + acdSfpThreshRxPwrLowWarndBm DisplayString + +} + +acdSfpThreshID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique value for each SFP. Its value ranges from 1 to + MAXINT (4 bytes). " + ::= { acdSfpThreshEntry 1 } + +acdSfpThreshConnIdx OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the connector index on the box. The index + is assigned form left to rigth starting with 1." + ::= { acdSfpThreshEntry 2 } + +acdSfpThreshTempHighAlm OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm transceiver temperature. Represented as a 16 bit + signed twos complement value in degrees Celsius, yielding + a total range of -128C to +128C." + ::= { acdSfpThreshEntry 3 } + +acdSfpThreshTempLowAlm OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm transceiver temperature. Represented as a 16 bit + signed twos complement value in degrees Celsius, yielding + a total range of -128C to +128C." + ::= { acdSfpThreshEntry 4 } + +acdSfpThreshTempHighWarn OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning transceiver temperature. Represented as a 16 bit + signed twos complement value in degrees Celsius, yielding + a total range of -128C to +128C." + ::= { acdSfpThreshEntry 5 } + +acdSfpThreshTempLowWarn OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning transceiver temperature. Represented as a 16 bit + signed twos complement value in degrees Celsius, yielding + a total range of -128C to +128C." + ::= { acdSfpThreshEntry 6 } + +acdSfpThreshVccHighAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm transceiver supply voltage. Represented as + a 16 bit unsigned integer with the voltage defined as the full + 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, + yielding a total range of 0 to +6.55 Volts." + ::= { acdSfpThreshEntry 7 } + +acdSfpThreshVccLowAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm transceiver supply voltage. Represented as + a 16 bit unsigned integer with the voltage defined as the full + 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, + yielding a total range of 0 to +6.55 Volts." + ::= { acdSfpThreshEntry 8 } + +acdSfpThreshVccHighWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning transceiver supply voltage. Represented as + a 16 bit unsigned integer with the voltage defined as the full + 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, + yielding a total range of 0 to +6.55 Volts." + ::= { acdSfpThreshEntry 9 } + +acdSfpThreshVccLowWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning transceiver supply voltage. Represented as + a 16 bit unsigned integer with the voltage defined as the full + 16 bit value (0 to 65535) with LSB equal to 100 micro-Volt, + yielding a total range of 0 to +6.55 Volts." + ::= { acdSfpThreshEntry 10 } + +acdSfpThreshLbcHighAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm TX bias current in micro-Amps yielding a total range of + 0 to 131 mA." + ::= { acdSfpThreshEntry 11 } + +acdSfpThreshLbcLowAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm TX bias current in micro-Amps yielding a total range of + 0 to 131 mA." + ::= { acdSfpThreshEntry 12 } + +acdSfpThreshLbcHighWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning TX bias current in micro-Amps yielding a total range of + 0 to 131 mA." + ::= { acdSfpThreshEntry 13 } + +acdSfpThreshLbcLowWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning TX bias current in micro-Amps yielding a total range of + 0 to 131 mA." + ::= { acdSfpThreshEntry 14 } + +acdSfpThreshTxPwrHighAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm TX output power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 15 } + +acdSfpThreshTxPwrLowAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm TX output power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 16 } + +acdSfpThreshTxPwrHighWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning TX output power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 17 } + +acdSfpThreshTxPwrLowWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning TX output power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 18 } + +acdSfpThreshRxPwrHighAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm RX input power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 19 } + +acdSfpThreshRxPwrLowAlm OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm RX input power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 20 } + +acdSfpThreshRxPwrHighWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning RX input power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 21 } + +acdSfpThreshRxPwrLowWarn OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning RX input power in mW. Represented as a 16 bit unsigned + integer with the power defined as the full 16 bit value (0 to 65535) + with LSB equal to 0.1 micro-Watt, yielding a total range of 0 + to 6.5535 mW (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 22 } + +acdSfpThreshTxPwrHighAlmdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm TX output power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 23 } + +acdSfpThreshTxPwrLowAlmdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm TX output power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 24 } + +acdSfpThreshTxPwrHighWarndBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning TX output power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 25 } + +acdSfpThreshTxPwrLowWarndBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning TX output power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 26 } + +acdSfpThreshRxPwrHighAlmdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Alarm Rx input power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 27 } + +acdSfpThreshRxPwrLowAlmdBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Alarm Rx input power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 28 } + +acdSfpThreshRxPwrHighWarndBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Warning Rx input power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 29 } + +acdSfpThreshRxPwrLowWarndBm OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Warning Rx input power in dBm (~ -40 to +8.2 dBm)." + ::= { acdSfpThreshEntry 30 } + +------------------------------------------------------------------------------ + -- The Alarm and Warning Thresholds SFP Status table + -- This table contains all statuses for the SFP Alarm and Warning Thresholds. +------------------------------------------------------------------------------ + +acdSfpThreshStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcdSfpThreshStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table of all SFP Digital Diagnostics Thresholds statuses" + ::= { acdSfp 4 } + +acdSfpThreshStatusEntry OBJECT-TYPE + SYNTAX AcdSfpThreshStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a part the content of the SFP's 0xA2 EEPROM" + INDEX { acdSfpThreshStatusID } + ::= { acdSfpThreshStatusTable 1 } + + +AcdSfpThreshStatusEntry ::= SEQUENCE { + acdSfpThreshStatusID Unsigned32, + acdSfpThreshStatusConnIdx Unsigned32, + acdSfpThreshStatusTempHighAlm TruthValue, + acdSfpThreshStatusTempLowAlm TruthValue, + acdSfpThreshStatusTempHighWarn TruthValue, + acdSfpThreshStatusTempLowWarn TruthValue, + acdSfpThreshStatusVccHighAlm TruthValue, + acdSfpThreshStatusVccLowAlm TruthValue, + acdSfpThreshStatusVccHighWarn TruthValue, + acdSfpThreshStatusVccLowWarn TruthValue, + acdSfpThreshStatusLbcHighAlm TruthValue, + acdSfpThreshStatusLbcLowAlm TruthValue, + acdSfpThreshStatusLbcHighWarn TruthValue, + acdSfpThreshStatusLbcLowWarn TruthValue, + acdSfpThreshStatusTxPwrHighAlm TruthValue, + acdSfpThreshStatusTxPwrLowAlm TruthValue, + acdSfpThreshStatusTxPwrHighWarn TruthValue, + acdSfpThreshStatusTxPwrLowWarn TruthValue, + acdSfpThreshStatusRxPwrHighAlm TruthValue, + acdSfpThreshStatusRxPwrLowAlm TruthValue, + acdSfpThreshStatusRxPwrHighWarn TruthValue, + acdSfpThreshStatusRxPwrLowWarn TruthValue +} + +acdSfpThreshStatusID OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique value for each SFP. Its value ranges from 1 to + MAXINT (4 bytes). " + ::= { acdSfpThreshStatusEntry 1 } + +acdSfpThreshStatusConnIdx OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the connector index on the box. The index + is assigned form left to rigth starting with 1." + ::= { acdSfpThreshStatusEntry 2 } + +acdSfpThreshStatusTempHighAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the temperature reaches or overpasses the High + alarm threshold." + ::= { acdSfpThreshStatusEntry 3 } + +acdSfpThreshStatusTempLowAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the temperature reaches or underpasses the Low + alarm threshold." + ::= { acdSfpThreshStatusEntry 4 } + +acdSfpThreshStatusTempHighWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the temperature reaches or overpasses the High + warning threshold." + ::= { acdSfpThreshStatusEntry 5 } + +acdSfpThreshStatusTempLowWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the temperature reaches or underpasses the Low + warning threshold." + ::= { acdSfpThreshStatusEntry 6 } + +acdSfpThreshStatusVccHighAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the supply voltage reaches or overpasses the High + alarm threshold." + ::= { acdSfpThreshStatusEntry 7 } + +acdSfpThreshStatusVccLowAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the supply voltage reaches or underpasses the Low + alarm threshold." + ::= { acdSfpThreshStatusEntry 8 } + +acdSfpThreshStatusVccHighWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the supply voltage reaches or overpasses the High + warning threshold." + ::= { acdSfpThreshStatusEntry 9 } + +acdSfpThreshStatusVccLowWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the supply voltage reaches or underpasses the Low + warning threshold." + ::= { acdSfpThreshStatusEntry 10 } + +acdSfpThreshStatusLbcHighAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Laser Bias Current reaches or overpasses + the High alarm threshold." + ::= { acdSfpThreshStatusEntry 11 } + +acdSfpThreshStatusLbcLowAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Laser Bias Current reaches or underpasses + the Low alarm threshold." + ::= { acdSfpThreshStatusEntry 12 } + +acdSfpThreshStatusLbcHighWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Laser Bias Current reaches or overpasses + the High warning threshold." + ::= { acdSfpThreshStatusEntry 13 } + +acdSfpThreshStatusLbcLowWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Laser Bias Current reaches or underpasses + the Low warning threshold." + ::= { acdSfpThreshStatusEntry 14 } + +acdSfpThreshStatusTxPwrHighAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Transmit Power reaches or overpasses the High + alarm threshold." + ::= { acdSfpThreshStatusEntry 15 } + +acdSfpThreshStatusTxPwrLowAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Transmit Power reaches or underpasses the Low + alarm threshold." + ::= { acdSfpThreshStatusEntry 16 } + +acdSfpThreshStatusTxPwrHighWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Transmit Power reaches or overpasses the High + warning threshold." + ::= { acdSfpThreshStatusEntry 17 } + +acdSfpThreshStatusTxPwrLowWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Transmit Power reaches or underpasses the Low + warning threshold." + ::= { acdSfpThreshStatusEntry 18 } + +acdSfpThreshStatusRxPwrHighAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Receive Power reaches or overpasses the High + alarm threshold." + ::= { acdSfpThreshStatusEntry 19 } + +acdSfpThreshStatusRxPwrLowAlm OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Receive Power reaches or underpasses the Low + alarm threshold." + ::= { acdSfpThreshStatusEntry 20 } + +acdSfpThreshStatusRxPwrHighWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Receive Power reaches or overpasses the High + warning threshold." + ::= { acdSfpThreshStatusEntry 21 } + +acdSfpThreshStatusRxPwrLowWarn OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is to indicate if the Receive Power reaches or underpasses the Low + warning threshold." + ::= { acdSfpThreshStatusEntry 22 } + +--------------------------------------------------------------------------- + -- ACD-SFP-MIB Module - Conformance Information +--------------------------------------------------------------------------- + +acdSfpCompliances OBJECT IDENTIFIER ::= { acdSfpConformance 1 } +acdSfpGroups OBJECT IDENTIFIER ::= { acdSfpConformance 2 } + +--------------------------------------------------------------------------- + -- Units of conformance +--------------------------------------------------------------------------- + +acdSfpInfoGroup OBJECT-GROUP + OBJECTS { + acdSfpInfoConnIdx, + acdSfpInfoConnType, + acdSfpInfoVendor, + acdSfpInfoVendorOui, + acdSfpInfoVendorPn, + acdSfpInfoVendorRev, + acdSfpInfoWavelength, + acdSfpInfoSerialNum, + acdSfpInfoYear, + acdSfpInfoMonth, + acdSfpInfoDay, + acdSfpInfoLot, + acdSfpInfoRev8472, + acdSfpInfoPresent, + acdSfpInfoDiag, + acdSfpInfoInternal, + acdSfpInfoAlm, + acdSfpInfoIdType, + acdSfpInfoExtIdType, + acdSfpInfoTransCode + } + STATUS current + DESCRIPTION + "Objects for the SFP information Group." + ::= { acdSfpGroups 1 } + +acdSfpDiagGroup OBJECT-GROUP + OBJECTS { + acdSfpDiagConnIdx, + acdSfpDiagTemp, + acdSfpDiagVcc, + acdSfpDiagLbc, + acdSfpDiagTxPwr, + acdSfpDiagRxPwr, + acdSfpDiagTxPwrdBm, + acdSfpDiagRxPwrdBm + } + STATUS current + DESCRIPTION + "Objects for the SFP diagnostics Group." + ::= { acdSfpGroups 2 } + +acdSfpThreshGroup OBJECT-GROUP + OBJECTS { + acdSfpThreshConnIdx, + acdSfpThreshTempHighAlm, + acdSfpThreshTempLowAlm, + acdSfpThreshTempHighWarn, + acdSfpThreshTempLowWarn, + acdSfpThreshVccHighAlm, + acdSfpThreshVccLowAlm, + acdSfpThreshVccHighWarn, + acdSfpThreshVccLowWarn, + acdSfpThreshLbcHighAlm, + acdSfpThreshLbcLowAlm, + acdSfpThreshLbcHighWarn, + acdSfpThreshLbcLowWarn, + acdSfpThreshTxPwrHighAlm, + acdSfpThreshTxPwrLowAlm, + acdSfpThreshTxPwrHighWarn, + acdSfpThreshTxPwrLowWarn, + acdSfpThreshRxPwrHighAlm, + acdSfpThreshRxPwrLowAlm, + acdSfpThreshRxPwrHighWarn, + acdSfpThreshRxPwrLowWarn, + acdSfpThreshTxPwrHighAlmdBm, + acdSfpThreshTxPwrLowAlmdBm, + acdSfpThreshTxPwrHighWarndBm, + acdSfpThreshTxPwrLowWarndBm, + acdSfpThreshRxPwrHighAlmdBm, + acdSfpThreshRxPwrLowAlmdBm, + acdSfpThreshRxPwrHighWarndBm, + acdSfpThreshRxPwrLowWarndBm + } + STATUS current + DESCRIPTION + "Objects for the SFP thresholds Group." + ::= { acdSfpGroups 3 } + +acdSfpThreshStatusGroup OBJECT-GROUP + OBJECTS { + acdSfpThreshStatusConnIdx, + acdSfpThreshStatusTempHighAlm, + acdSfpThreshStatusTempLowAlm, + acdSfpThreshStatusTempHighWarn, + acdSfpThreshStatusTempLowWarn, + acdSfpThreshStatusVccHighAlm, + acdSfpThreshStatusVccLowAlm, + acdSfpThreshStatusVccHighWarn, + acdSfpThreshStatusVccLowWarn, + acdSfpThreshStatusLbcHighAlm, + acdSfpThreshStatusLbcLowAlm, + acdSfpThreshStatusLbcHighWarn, + acdSfpThreshStatusLbcLowWarn, + acdSfpThreshStatusTxPwrHighAlm, + acdSfpThreshStatusTxPwrLowAlm, + acdSfpThreshStatusTxPwrHighWarn, + acdSfpThreshStatusTxPwrLowWarn, + acdSfpThreshStatusRxPwrHighAlm, + acdSfpThreshStatusRxPwrLowAlm, + acdSfpThreshStatusRxPwrHighWarn, + acdSfpThreshStatusRxPwrLowWarn + } + STATUS current + DESCRIPTION + "Objects for the SFP threshold status Group." + ::= { acdSfpGroups 4 } + +acdSfpCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for support of the ACD-SFP-MIB module." + MODULE + MANDATORY-GROUPS { + acdSfpInfoGroup, + acdSfpDiagGroup, + acdSfpThreshGroup, + acdSfpThreshStatusGroup + } + + ::= { acdSfpCompliances 1 } + +END -- cgit v1.2.3